Plans (11) MSS 5-- 2C5
LEGEND DETACHED MIN. SETBACK SUMMARY
SANITARY SEWER PORCH SETBACK: 8'
STORM DRAIN I \ I BUILDING SETBACK: 12'
I SIDE SETBACK: 3' .
WATER LINE — f _ _ -- I SIDE FACING STREET: p -
I I --it_ -- � — PUBLIC STREETS: 8' 7
WATER VALVE — I _ ALLEY/PRIVATE STREETS: 3' Rt*? tee
r SANITARY MANHOLE -- SW MELBOURNE LANE REAR SETBACK: 15'
REAR SETBACK AT ALLEY/PRIVATE: 0' TaylorMorrison
• STORM MANHOLE LATERALS REAR COVERED PATIO: 10'
GARAGE:
D CATCH BASIN
5 1r 3.00' PUBLIC STREETS: 20'
ELECTRICAL VAULT 3.6a' PUE ALLEY/PRIVATE STREET: 3-5'
30.29' 28a.6
• SIGN
SIDEWALK 12.71' PACIFIC COMMON +as9an
�iy 16.00'
12564 SW Main Street
1-- V — DWY -- - - —— — Tigard,OR 97223
/. GRADE ELEVATION _282.5 — 16.61' 4.00' LOT COVERAGE:
180.2 �' - I>7 503-941-9484
• LIGHT POLE GFF=284.3 '
/ DATE: 06-29-2023
LOT AREA: 3,010 SF
x r-x; STRAW WATTLE PERIMETER EROSION GARAGE BUILDING FOOTPRINT: 1,315 SF
CONTROL
_ SURFACE FLOW ARROW PATIO r_ IMPERVIOUS AREA: 1,839 SF RECEIVED
1 '
—0— TREE PROTECTION FENCING 1 ra J LOT COVERAGE 61.1 % L� I 2 3 2023
E.
FF=285.6 c ,
E.
°; 1 WATER METER 'i o r ^TV r TIGARD
D
i 1 O CI l r ®f 11\A,QRV
o co
FF= FINISH FLOOR ELEVATION o 107 BUILDING DIVISION
'' GFF= GARAGE FINISH FLOOR ELEVATION Oo 108
N PUE PUBLIC UTILITY EASEMENT ao
PSDE STORM DRAINAGE EASEMENT.-, //:
3,010 SF
PSWE PUBLIC SIDEWALK EASMENT
co
o PWLE PRIVATE WATER LINE EASEMENT 1 Y f_
pLAT
PRUE PRIVATE UTILITY EASEMENT r �r 4 00'
i
�S.or r SOUTH
`„ � PORCH ' ' 7
°° a RIVER
5 1 o
1.59' 19.48 �'�
I TERRACE
N � :-_- 2 — -13.49'- F2799—•_j
r- —
_ . — _ — — NO. 2
-- -- - 12.71' WATER cc 19.52' TRACT f
IDEWALK_ SERVICE
5 L. <x, _5.00'
—� PRUE'—
__ _
0. \
PLOT PLAN
M LOT 108
o
P
ry
WN
Q
ITRACT W
j
TAYLOR MORRISON (360) 695-7700
...
2S1W7
el
E PROJECT NO.: 3
LOT 108, ZONE: R-12, PLAN: 483200B TYPE: PERMITTING
TING
O REVIEWED By CMH
SOUTH RIVER TERRACE PH 2 SCALE
M 16570 SW MELBOURNE LANE I 1.3ra°x3lo
°
TIGARD, OREGON 97224 , INCH=2°FEET
Z
1Xl CONFORMS TO DESIGN CONCEPT
❑ CONFORMS TO DESIGN CONCEPT WITH
REVISIONS NOTED
ALL TRUSS TO BUILDING CONNECTIONS ❑ NON-CONFORMING-REVISE&RESUBMIT
ARE THE RESPONSIBILTY OF THE BUILDING THIS SHOP DRAWING HAS BEEN REVIEWED FOR GENERAL CONFORMANCE
WITH DESIGN CONCEPT ONLY AND DOES NOT RELIEVE THE
DESIGNER OR THE ENGINEER OF RECORD FABRICATORNENDOR OF RESPONSIBILITY FOR CONFORMANCE WITH DESIGN
DRAWINGS,SPECIFICATIONS,AND APPLICABLE CODES,ALL OF WHICH HAVE
PRIORITY OVER THIS SHOP DRAWING.
USE LUS24 UNO By Rhea Galvezo Date 11/16/21
MILBRANDT ARCHITECTS
26-00-00
4-00-00 22 00 00 Ri
AUGvED
2 3 2023
CITY OF TIGARD
BUILDING DIVISION
B01
\ _i- <I -
>a .—__._.. ---- oD
9 — 6/12 -
1 c-
CNI
gp f
- -.--.--
1 —
O
1.0
N 6/12
CVa O
m
--s—
4/12
( 'A o
- -
0o JO1 3 00 00 0
0
A04
0
co o
II
0
v
ll
- sI
6/12 co
9c.
CO I ,, - I
9 2-00-00 -- -
N
I I
1
CO
9 0 7-1/2" RAISED CV
AB . COFFER --o Q
N O
A
O
I
N I
A01
EDGEF�
CO2 2-Ob-00 2X L 2-11-00
CO1 2X L=DGEIC N
cv
0 0
9
J03(81 J04(4)
7 V , 7- - -----4.._ 7 7 °' I ® CONFORMS TO DESIGN CONCEPT
❑ CONFORMS TO DESIGN CONCEPT WITH
REVISIONS AS SHOWN
16-06-08 9-05-08 ❑ NON-CONFORMING-REVISE AND RESUBMIT
/
THIS SHOP DRAWING HAS BEEN REVIEWED FOR GENERAL CONFORMANCE
WITH THE DESIGN CONCEPT ONLY AND DOES NOT RELIEVE THE
FABRICATOR/VENDOR OF RESPONSIBILITY FOR CONFORMANCE WITH THE
26-00-00 OVER GNN HIRA INGSOANDISPECIFICATIONS ALL OF WHICH HAVE PRIORITY
24047 By; Y.E.Z. Date:11/17/2021
CT ENGINEERING,INC.
BUILDER: TAYLOR MORR-POLYGON DATE: 11-12-21
ABOVE PLAN PROVIDED FOR TRUSS Dam ,Lumber
- PLACEMENT ONLY.REFER TO TRUSS r
LOT: SUBDIV: SOUTH RIVER TERRACE LOAD: 25-7-10 (COMP) CALCULATIONS
T UCTURIA"DRAwlNcs ENGINEERED
ALLL & TRUSS COMPANY
FURTHER INFORMATION.BUILDING
DESIGNER/ENGINEER OF RECORD
RESPONSIBLE FOR ALL NON-TRUSS
PLAN: 483200B SALES: PW TO TRUSS CONNECTION.BUILDING
DESIGNER/ENGINEER OF RECORD TO 10515 SW ALLEN BLVD.
REVIEW AND APPROVE OF ALL BEAVERTON,OR 97005
DESIGNS PRIOR TO CONSTRUCTION PHONE (503)858-9663
DEL LOC: TIGARD, OREGON DES: ECR
All designs are property of Pacific Lumber & Truss Co. All designs are null & void if not fabricated by Pacific Lumber & Truss Co.