Permit (113) CITY OF TIGARD MASTER PERMIT
COMMUNITY DEVELOPMENT Permit#: MST2023-00485
T"It. 1l 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 10/16/2023
Parcel: 2S111AA01500
Jurisdiction: Tigard
Site address: 14445 SW 87TH CT
Subdivision: GREENSWARD PARK Lot: 23
Project: Flatt
Project Description: Rooftop solar PV system 11.6 kW with 200 amp service and(3)circuits.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $10,000.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Bckflw Prevntr: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Fum>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 3
Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401.600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+ampNolt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N
Other: V Other Description: Rooftop solar array 11.6 kW Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VE R-3 0
Owner: Contractor:
FLATT,JOSHUA ELWOOD UNITY ELECTRICAL SERVICE LLC Required Items and Reports(Conditions)
14445 SW 87TH CT 15715 NE 42ND ST
TIGARD,OR 97224 VANCOUVER,WA 98682
PHONE: PHONE: 971-379-7380
FAX:
Total Fees: $488.90
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordanc' ith approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTEN • •regon law requi ou to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
aS91nn11M1n thrnn •c9-nn1-nnon v av fain a rnnv of tha n doe nr rlirnrt m iectinne to fll IN(:by rallinn AM 949 10a7 nr 1 ann 949 Ytdd
Issued By: / i Permittee Signature:
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each Inspection.
Building Permit Application
Residential /� / FOR OFFICE USE ONL\
Received 1 Nil
i ( /L V\Y M 1 I l(J//3 l U) 1{1 5
City of Tigard pent o
'� : 5ECEIVEDDat�y:
13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review a
Phone: 503.718.2439 Fax: 503.598.196 Date/By: �(� ��jj A,�- Other Permit:
'f 1 G A R U Inspection Line: 503.639.4175 2023 Date Ready/ey: /, r1 r +s' ® See Page 2 for
Internet: www.tigard-or.gov SEP 2 0 L J Noti6ed/M�thod• Iv+ �� {� Supplemental information
TYPE OF WORK CITY OF T OMO � � JVM\
r$CITY GARDlvislor� REQUIRED DATA:I-AND 2-FAMILY DWELLING
❑New construction ❑De o r ton Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
C❑Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
Valuation: $ 10,000.00❑ I-and 2-family dwelling^_ 0Commercial/industral ElAccessory building El Multi-family Number of bedrooms:
❑Master builder ❑Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: 14445 SW 87TH CT New dwelling area: square feet
City/State/ZIP: Tigard,Oregon 97224 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name: Flatt Residence Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Lot no.: Permit fees*are based on the value of the work performed.
25111 AA01500 Indicate the value(rounded to the nearest dollar)of all
Tax map/parcel no.: ui equipment,materials,labor,overhead,eq p and the profit for the
DESCRIPTION OF WORK work indicated on this application.
11.6kW Solar Roof Mount Installation Valuation: $
Existing building area: square feet
New building area: square feet
0 PROPERTY OWNER 0 TENANT Number of stories:
Name: JAMES ELWOOD FLATT Type of construction:
Address: 14445 SW 87TH CT Occupancy groups:
City/State/ZIP: Tigard,Oregon 97224 Existing:
Phone: ) 253)740- 182 Fax:( ) New:
c ❑0 APPLICANT 0 CONTACT PERSON BUILDLNG PERMIT FEES*
Business name: Unity Electrical Service LLC (Please refer to fee schedule)
Cla on Tarkalson Structural plan review fee(or deposit):
Contact name:
Address: 15715 NE 42nd street
FLS plan review fee(if applicable):
Total fees due upon application:
City/State/ZIP: Vancouver WA 98682
Phone:( ) 9713561593 Fax::( ) Amount received:
E-mail: permitting@unity-solar.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
CONTRACTOR Commercial and residential prescriptive installation of
roof-top mounted PhotoVoltaic Solar Panel System.
Business name: UNITY ELECTRICAL SERVICE LLC Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address: 15715 NE 42nd street Solar Installation Specialty Code checklist.
City/state/ZIP:Vancouver WA 98682 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:( ) 9713561593 Fax:( )
CCB lic.: 234553 State surcharge(12%of permit fee): $21.60
Total fee due upon application: $201.60
Authorized signature: This permit application expires if a permit is not obtained
`` ``__ within 180 days after it has been accepted as complete.
Print name: cJ/L�G(J4Jl.� Date: 2/17/23 *Fee methodology set by Tri-County Building Industry
Service Board.
(:\Building\P SUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
Electrical Permit Application RECEIVE FOR OFFICE USE ONI,Y
City of Tigard Received
IemtnVi4!1,013'00,4S
;, 'II
SW Hall Illvd.,Tigard,OR 97223 SEP 2 0 2023 Plan Review
Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit#:
t�;�I!! Inspection Line: 503.639.4175 Ready Date/By: Suns: See Page 2 for
I Internet: www.tigard-or.gov CITY OF TIGAR I Noti tied/Method: Supplemental information
W®RifP,!0ixjoi�`u, rt _...
PLAN REVIEW
❑New construction Addition/alteIation/replaeemetl Please check all that apply(submit 2 sets of plans w/items checked):
0 Demolition ❑Other: ❑Service or feeder 400 amps or more ElBuilding over three stories.
where the available fault current ❑Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings.
Z1-and 2-familydwel li0Accessorybuilding less to ground,or exceeds 14,000 0 Commercial-use agricultural
0Commercial/industrial
amps for all other installations. buildings.
❑Multi-family 0 Master builder ❑Other: ❑Fire pump. ❑Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived
❑Addition of new motor load of system.
Job#: Job site address: 14445 SW 87TH CT 100HP or more. ❑"A","E","1-2","1-3",
City/State/ZIP: Tigard,Oregon 97224 0 Six or more residential units. occupancy.
❑Health-care facilities. 0 Recreational vehicle parks.
Suite/bldg./apt.#: Project name: Flail Residence 0 Hazardous locations_ ❑Supply voltage for more than
0 Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: FEE SCHEDULE
Description I Qty. 1 Each I Total I '
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#; :2S111 AA01500 Ea.add'l 500 sq.ft.or portion 33.92 I
DESCRIPTION OF WORK Limited energy,residential 75.00 2
(with above sq.ft.)
11.6 kW Solar Roof Mount Installation Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
Renewable Energy 0 See Page 2
❑ TENANT
0 PROPERTY OWNER Services or feeders installation,alteration,and/or relocation
Name: James Ellwood Flatt 200 amps or less 1 100.70 2
Address: 14445 SW 87TH CT 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard,Oregon 97224 601 amps to 1,000 amps 301.04 2
Phone:( ) (253)740-6182 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email: elwoodjf@gmail.com relocation
Owner installation:This installation is being made on property that 1 own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signs _ Date: 401 amps to 599 amps 168.54 2
APPLICANT ) ❑ CONTACT PERSON Branch circuits—new,alteration,or extension,per panel
_111A.Fee for branch circuits with
Business name: UNITY ELECTRICAL SERVICE LLC above service or feeder fee, 3 7.42 2
each branch circuit
Contact name: Clayton Tarkalson H.Fee for branch circuits without
15715 NE 42nd street service or feeder fee,first
Address: branch circuit 56.18 2
City/State/ZIP:Vancouver WA 98682 Each add'I branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:( ) 971-379-7380 Fax: :( ) Each manufactured or modular
dwelling,service and/or feeder 67.84 2
Email: permitting@unity-solar.com Reconnect only 67.84 2
CONTRACTOR _ Pump or irrigation circle 67.84 2
Business name: UNITY ELECTRICAL SERVICE LLC Sign or outline lighting 67.84 2
Address: 15715 NE 42nd street Signal circuit(s)or limited-energy ❑ See Page 2 2
panel,alteration,or extension.
City/State/ZIP: Vancouver WA 98682 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone:( ) 9713561593 Fax:( ) Investigation(1 hr min) 90.00/hr
Industrial plant I hr min 78.18/hr
Email: permitting@unity-solar.com p ( )
Inspections for which no fee is 90.001 hr
CCB Lic.: 234553 Electrical Lie.: C1599 Suprv.Lie.:4619S specifically listed(%hr min) I
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,required: _4 � ,, Subtotal.
Print name: Daniel Broughton Date: 7/17/23 0 Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee):
Authorized signature: TOTAL PERMIT FEE:
7l17/23 This permit application expires if a permit is not obtained within 180
Print name: 7L 7CJn6ir��a/L Date: days after it has been accepted as complete.
' Number of inspections allowed per permit.
C\Buildina\Permits1ELC Perms _ELR_ERS.doc Rev 06/17/2015 440-46151(1 I/05/COM/WEB
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Fee for all residential systems combined: $75.00 °neriptioa I Qty. l Each I Total I *
Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 1 133.56 2
❑ Audio and Stereo Systems* 15.01 to25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
❑ Garage Door Opener* 50.0l to loo kva 552.26 2
>100 kva(fee in accordance 552.26 2
with OAR 918-309-0040)
❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System*
Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr 1
charged at an hourly(I hr min)
Inspections for which no fee is 90.00/hr
specifically listed I!:hr min)
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES
Fee for each commercial system: $75.00 Subtotal(Enter on Page 1):
Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
El Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
n Intercom and Paging Systems
❑ Landscape Irrigation Control*
n Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
n Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I.\Building\Pormits\EL.C.PermitApp_ELR EREdoc Rev 06/17/2015
RECEIVED
City of Tigard SEP 2 0 2023
CITY OF TIGARD
'' Building Division BUILDING DIVISION
MI
13125 SW Hall Blvd,Tigard, OR 97223
Phone: 503.718.2439 Fax: 503.598.1960
TIGARD Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 14445 SW 87TH CT
City: Tigard,Oregon Zip: 97224
Owner's Name: JAMES ELWOOD FLAT Date: 7/17/2023
Contractor's Name: Unity Electrical Service LLC CCB #: 234553
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Located in a flood prescriptive path, follow
Area plain/flood way? C No 2) OSSC or ORSC for
design requirements.
Is the wind exposure CD Ye_sD If"Yes", qualifies for
Wind Exposure "C"or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes Clil Ye' the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
above the prescriptive path.
❑ No
1,
I:Building/Fonns/Photo Voltaic-Checklist02-OI-11.docx
Is the construction
Type of material wood and does El Yes If"Yes", qualifies for
Construction the construction qualify El No the prescriptive path.
as"conventional light
frame" construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. Ye) te prespaveies for
thhe prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. If"Yes", qualifies for
the prescriptive path.
❑ No
Is the combined weight ❑ Yes
of the PV modules and If"Yes",qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
10 layout in accordance 414 If"Yes",qualifies for
with Section 305.4(3)of
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
❑ Metal
'ingle layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
❑ of composition
shingle.
Is the roof mounted ❑ YeD
Connections of solar assembly
the solar assembly connected to roof No te ey pfies for
to the roof framing or blocking ❑ thhe p prrescriptt ivve path.
directly?
2
I:Build ing/Forms/PhotoVol taic-Checkl ist02-01-11.docx
Is the gauge 26 or less? ❑ Yes If"Yes",qualifies for
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes",qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to 24 inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
18 inches qualifies for the
prescriptive path.
Minimum #10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? El Yes the prescriptive path.
❑ No
Is the roof decking of ❑
WSP min. 'A"thickness, Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes",qualifies for
solar modules module to the roof YeD the prescriptive path.
surface. ❑ No
3
I1Building/Forms/Photovoltaic-Checklist02-OI-I I.docx
I
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: HANWHA Q-CELLS
Model Number: Q.PEAK DUO BLK ML-G10+400W
Listing Agency: UL61730
4
C/Building/Fortis/Photo Voltaic-Checkl ist02-0I-11.docx