Loading...
Permit (143) 74 CITY OF TIGARD MASTER PERMIT _: ' COMMUNITY DEVELOPMENT Permit#: MST2023-00572 Date Issued: 11/09/2023 T[GAR D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S110BC07600 Jurisdiction: Tigard Site address: 12380 SW ASPEN RIDGE DR Subdivision: THORNWOOD Lot: 47 Project: Sui Project Description: Rooftop solar PV system. 14.985 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Right: 0 Detectors: Dwelling Units: 0 Third: 0 sf Ri 9 Total: 0 sf Value: $9,412.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: Storm Sewer: 0 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning; N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc(Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Rooftop solar array 14.985 kW Ecompasing: BUILDING INFO Type of Work: T e of Use: Type of Constr: Occupancy Group: Square Feet: 0 OTR SF VB R-3 Owner: Contractor: SUI,YI TML INTERNATIONAL LLC Required Items and Reports(Conditions) 12380 SW ASPEN RIDGE DR 6405 E MILL PLAIN BLVD TIGARD,OR 97224 VANCOUVER,WA 98661 PHONE: PHONE: 800-364-0470 FAX: Total Fees: $359.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oF9J1n111Mn thr n (lAR g59.11M-nnon nhfain,rnnv of the ndae nr direr+ni,eclinnc fn Ill IIJC hw rallinn FM 939 10R7 nr 1 Ann 119 71d4 Issued By: - Permittee Signature: r Call 503.639. 175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. Building Permit Application • Residential FOR OFFICE USE ONLY City of Tigard t m, Received p�—rh yc, '� FS° .t 'P Permit No 111 13125 SW Hall Blvd.,Tigard,OR 97223 t p `' "�L o if f L .I 'tan Rev �� y l yvZ3'gp MS��Z3'OO51ti �„� , , Ian Review ? Other Permit. III Phone: 503.718.2439 Fax: 503.598.196 Dated3y: J l"I G A R.D Inspection Line: 503.639.4175 OCT1 q q Date ReadyBy: 6 orris: 0 See Page 2 for Internet: www.tigard-or gov GC). .1 2023 NotitiediMlethod: II 7/�� 4 7—_ I Supplemental Information et r"N� f TYPE OF WORK REQU ED DATA:1-AND 2-FAMILY DWELLING Permit fees*are based on the value of the work performed. ['New construction 0 Uer'notrtionIj BT Indicate the value(rounded to the nearest dollar)of all El Addition/alteration/replacement ❑� Other:Solar equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑j I-and 2-family dwelling ❑Commercial/industrial Valuation: $9412.00 ❑Accessory building 0 Multi-family Number of bedrooms: ❑ Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:12380 SW Aspen Ridge Dr New dwelling area: square feet City/State/ZIP:Tigard OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Solarinstall-YSul Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST • Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.. Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of 37 solar panels in 4 arrays on a roof-mounted 14.985kw PV System Valuation: $ Existing building area: square feet New building area: square feet ®PROPERTY OWNER 0 TENANT Number of stories: Name:Yl Sui Type of construction: Address:12380 SW Aspen Ridge Dr Occupancy groups: City/State/ZIP:Tigard OR 97224 Existing: Phone:( )614-962-1956 Fax:( I New: I9 APPLICANT IN CONTACT PERSON BUILDING PERMIT FEES* Business name:TML International LLC dba Infinity Solar USA (rrease refer ra fee schedule) Structural plan review fee(or deposit): Contact name:Mary Dinsmore-Smith FLS plan review fee(if applicable): Address:6405 E Mill Plain Blvd Total fees due upon application: City/State/ZIP:Vancouver,WA 98661 Amount received: Phone: ( )(360)326-0650 Fax::( ) PHOTOVOLTAIC SOLAR PANEL.SYSTEM FEES* E-mail:permit@infinitysolarusa.com Commercial and residential prescriptive installation of CONTRACTOR •, roof-top mounted PhotoVoltaic Solar Panel System. Business name:TML International LLC dba Infinity Solar USA Submit two(2)sets of roof plan with connection details and tire department access,along with the 2010 Oregon Address:6405 E Mill Plain Blvd Solar Installation Specialty Code checklist. City/State/ZIP:Vancouver,WA 98661 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( )(800)818-0598 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.:223690 Total fee due upon application: $201.60 Authorized signature: /� This permit application expires if a permit is not obtained jik)uurtrytatQ within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Print name:Mary Dinsmore Smit Date:10/17/2023 Service Board. 1:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I 1/02/COM/WEB) Electrical Permit Appllcaft� _g FOR OFFICE USE ONLY I , L gift. Received - City of Tigard a ..a,�; li k�,1166 Date/By: Permt 8: MS1 IIq , on G'-''r t .1 13125 S W Hall Blvd.,Tigard,OR 97223 T Plan Review '•1J LJ 1, Phone: 503.718.2439 Fax: 503 598 196(O fs! 20 DateBy: Related Permit k' TIGARD Inspection Line: 503 639 4175 v. I �J Ready Date/By lugs: I ® See Page 2 for Internet: www.tigard-or.gov Notificd'Method. Supplemental Information TYPE OF WORK. ..( PLAN REVIEW ❑Vox construction ❑ Addition/alterationheplacement Please check all that apply(submit 2 sets of plans w'items checked): ❑ DelnOhtlOn Other: Solar 0 Service or feeder 400 amps or more 0 Building over three stories. where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION : exceeds 10,000 amps at 150 volts or 0 Floating buildings. ❑� 1-and 2-family dwelling El Commercial/industrial ID Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural amps for all other installations, buildings. ❑Multi-family ❑Master builder ❑Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system larger separately derived ❑Addition of new motor load of system. Job#: Job site address:12380 SW Aspen Ridge Dr 100HP or more. ❑"A","E","1-2","I3", occupancy.Six or more residential units. City'/State/ZIP:Tigard OR 97224 ❑Recreational vehicle 0 Health-care facilities. parks. ❑Hazardous locations. 0 Supply voltage for more than Suite Bldg./apt.#: Project name:Solarinstall-YSuI ❑Son ice or feeder 600 amps or more. 600 oohs nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qis. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: I,ot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy, - - residential 75.00 2 Installation of 37 panels in 4 arrays on a roof-mounted 14.985kW PV system (��above sq.e.) Limited energy,multi-family 75.00 2 residential(with above sq.ft) Renewable Energy See Page 2 II PROPERTY OWNER ❑ TENANT Services or feeders installation,a Ic tion,and/or relocation Name:Yi Sui 200 amps or less 100.70 2 Address:12380 SW Aspen Ridge Dr 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard OR 97224 601 amps to 1,000 amps 301 04 2 Phone:( )614-962-1956 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:suiyi315@gmail.com relocation Owner installation: This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670. and 701. 201 amps to 400 amps 125.08 2 Owner signature:__ Date: 401 amps to 599 amps 168.54 2 II APPLICANT II CONTACT PERSON Branch circuits-new,alteration,or extension,per panel A.Fee for branch circuits with Business name:TML International LLC dba Infinity Solar USA above service or feeder fee, 7.42 2 each branch circuit Contact name:Mary Dinsmore-Smith B.Fee for branch circuits without Address:6405 E Mill Plain Blvd anct feetfee,first branch circui 56.18 2 brh City/State/ZIP:Vancouver WA 98661 Each add'l branch circuit 7 42 2 Phone: Miscellaneous(service or feeder not included) ( )614-962-1956 Fax: :( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email:suiyi315@gmail.com Reconnect only 67,84 2 _. CONTRACTOR Pump or irrigation circle 67.84 2 Business name:TML International LLC dba Infinity Solar USA Sign or outline lighting 67.84 2 ted Address:6405 E Mill Plain Blvd Signal circuit(s)or lextensionergy panel,alteration,or extension. 0 See Page 2 2 Ciry/State/ZIP:Vancouver WA 98661 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 6625/hr Phone:( )614-962-1956 Fax:( ) Investigation(I hr min) 90.00/hr Industrial plant(1 hr nun) 78.18/hr Email:suiyi315@gmail.eom Inspections for which no fee is CCB Lic.:223690 Electrical Lic.:C1556 Suprv.Lic.:4434S specifically listed 11,hr min) 9000'hr / � ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal: Print name:Todd Rouse Date:10/17/2023 ❑Plan Review Required(25%of permit fee) State surcharge(12%of permit fee): Authorized signature: �14+�¢I rrei.2_ TOTAL,PERMIT FEE This permit application expires if a permit is not obtained within 180 Print name:Mary Dinsmor meth Date:10/17/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. 1?Beilding'Permits`.ELC PermitApp_ELR_ERE.doe Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Description Qlv. I Each I Total Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 13356 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 1 200.34 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25i hr charged at an hourly(1 hr min) Inspections for which no fee is 90.00 hr specifically listed It' hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Subtotal(Enter on Page I). Fee for each commercial system: $75.00 Number ofinspections allowed per permit (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I tBuilding'PernutslELC_PermitApp_EIR_ERE.doc Rev 0 6/1 720 1 5 City of Tigard Building Division RECEIVED 13125 SW Hall Blvd,Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 OCT 3 1 2023 T I GARD Inspection Line: 503.639.4175 www.tigard-or.gov CITY OF TIGARD BUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12380 SW Aspen Ridge Dr City: Tigard Zip: 97224 Owner's Name:Yi Sui Date: 10/17/2023 Contractor's Name:TML International LLC dba Infinity Solar USA CCB #: 223690 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? • No OSSC or ORSC for design requirements. El Wind Exposure Is the wind exposure Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ❑■ Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures ❑ If"Yes", qualifies for other than Yes the prescriptive path. above ❑ No 1 IlB ui Iding/Forms/PhotoVoltaic-Checklist02-0I-I I.docx '- Is the construction material wood and does ❑■ Yes Type of If"Yes", qualifies for Construction the construction qualify ❑ No the prescriptive path. as"conventional light frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. • Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. D If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight ❑■ Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ❑■ Yes If"Yes", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer if roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ❑■ of composition shingle. Is the roof mounted ❑■ Yes Connections of solar assembly If e the solar assembly connected to roof No prescriptive spaes for ❑ to the roof framing or blocking the ei path. directly? 2 Il/Building/Forms/Photo Voltaic-Checklist02-0I-l l.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? 0 If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directl to inches inches, qualifies for the Y Maximum 60 inches prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum #10 at 24 inches o/c? Size and spacing of ❑ If"Yes", qualifies for fastener? Yes the prescriptive path. ❑ No Is the roof decking of WSP min. t/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for El solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 UBuilding/Forms/Photovoltaic-Checklist02-01-I I docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer:ZNSHINE Model Number:ZXM7-S H 108-405M Listing Agency:UL 61730 4 I:/Building/Forms/PhotoVoltaic-Checklist02-0I-11 docx