Loading...
Permit (142) CITY OF TIGARD MASTER PERMIT IN -' ' COMMUNITY DEVELOPMENT Permit#: MST2023-00573 Date Issued: 11/09/2023 T j C.-,A E 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S 09/202 7500 Jurisdiction: Tigard Site address: 12360 SW ASPEN RIDGE DR Subdivision: THORNWOOD Lot: 46 Project: Cantrell Project Description: Rooftop solar PV system. 12.8 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $10,467.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywall-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O SvclFdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Rooftop solar array 12.8 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: CANTRELL,DONALD P&DENISE L TML INTERNATIONAL LLC Required Items and Reports(Conditions) 12360 SW ASPEN RIDGE DR 6405 E MILL PLAIN BLVD TIGARD,OR 97224 VANCOUVER,WA 98661 PHONE: PHONE: 800-364-0470 FAX: Total Fees: $356.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law require o follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Q5911n1_rim n thr inh R 05911111-nnan Vn ' rnnv of tha r„lac nr rlirerl ni meting to r111NR by rallinn SO'i 9'39 1QR7 nr 1 Ann Z'39'n44 0,11 I + •'O Cl Issued By: Permittee Signature: �� / �' �'L Call 503.639.• . by 7:00 a.m.for the next available inspection date. ! This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential FOR OFFICE USE ONLY Received11 Permit No City of Tigard DECEIVE Date,By: n ti I�ti3. WP NIS12023.00513 • 13125 SW Hall Blvd.,Tigard,OR 9 Plan Review Phone: 503.718.2439 Fax: 503.598ection ine: -1960 Date/By.. I , • 7`a3 Other Pemut. Ins L 503.639.4175 OCT 3 2023 Date Ready/By: Saris-. ® See Page 2 for TIGr\Rl) p Internet: www.tigazd-or.gov Notified/Method: /1 7)-� I Supplemental Information CITY OF I C rRD :., 6# am vc.� ' DTYPEOF iktif DING D1 ' " 1 REQUIRED 1-AND 2-FAMILY DWELLING O New construction ❑Demolition in,y4,4 el- Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all 0 Addition/alteration/replacement ❑� Other:Solar equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $10467.00 ❑� 1-and 2-family dwelling ❑Commercial/industrial Number of bedrooms: ❑Accessory building 0 Multi-family Number of bathrooms: ❑Master builder ❑Other. JOB SITE INFORMATION AND LOCATION Total number of floors. Job site address:12360 SW Aspen Ridge Dr New dwelling area: square feet City/State/ZIP:Tigard, OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Solarinstall-DCantrell Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no_ Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel na: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of 32 solar panels in 4 arrays on a roof-mounted 12.800kW PV System Valuation: S Existing building area: square feet New building area: square feet 0 PROPERTY OWNER 0 TENANT Number of stories: Name:Don Cantrell Type of construction: Address:12360 SW Aspen Ridge Dr Occupancy groups. City/State/ZIP'Tigard, OR 97224 Existing: Phone I )503-298-9630 Fax:( ) New. UI APPLICANT 0 CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:TML International LLC dba Infinity Solar USA Structural plan review fee(or deposit): Contact name:Mary Dinsmore-Smith FLS plan review fee(if applicable): Address:6405 E Mill Plain Blvd Total fees due upon application: City/State/ZIP:Vancouver,WA 98661 Amount received: Phone:( )(360)326-0650 Fax: : ( ) - Pl1OTOVOLTAIC SOLAR PANEL SYSTEM FEES* F-mail:permit@infinitysolarusa.com Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name:TML International LLC dba Infinity Solar USA Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:6405 E Mill Plain Blvd Solar Installation Specially Code checklist. City/State/ZIP:Vancouver,WA 98661 Permit Fee(includes plan review $180.00 7 and administrative fees): Phone:( )360-326-0650 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB Sic.:223690 Total fee due upon application: $201.60 Authorized signature: e/ This permit application expires if a permit is not obtained D2,�^�{'12LllG within 180 days after it has been accepted as complete. *Fee methodology set by Tr;-County Building Industry Print name:Mary Dinsmore- mith Date:10/18/2023 Service Board. I.\Building\Permits 1BUP-RESPermitApp.doc 02/24/2011 440-4613T(I1/02/COM/WEB) electrical Permit Application FOR OFFICE USE ONLY City of Tigard CEIVE Received MS1�2 11G nn Date/By. Perntit k: • 13125 SW Hall Blvd.,Tigard,OR 9'/t : 3 5�3 Pril $ �� Plan Review Phone: 503.718.2439 Fax. 503.59 1 Date,By Related Permit 6: Inspection Line: 503.639.4175 Read Date/Byloci,.. TIGARD rr'* - 7(t'J9 Y ' H See Page2for Internet wwnv.tlgard-or.gov tJL.) Notified,Method Supplemental Information TYPE OF WORK . ....,, PLAN REVIEW 0 New construction Q Addition/alteration/replacement Plcasc check all that apply(submit 2 sets olplans wiitems checked): ❑ Demolition El Other: Solar 0 Service or feeder 400 amps or more 0 Building over three stories. where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. ID1-and 2-family dwelling ['Commercial/industrial ❑Accessory building less to ground.or exceeds 14,000 ❑Commercial-use ag cultural amps for all other installations. buildings. ❑Multi-family E Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived Job#: Job site address:12360 SW As en Rid a Dr 0 Addition of new motor load of system. P 9 1001-IP or more. ❑"A","E","1.2","1-3", City/State/ZIP:Tigard, OR 97224 0 Six or more residential units_ occupancy. ❑Health-care facilities_ 0 Recreational vehicle parks_ Suite/bldg./apt.#: Project name:Solarinstall-DCantrell 0 Hazardous locations. 0 Supply voltage for more than 0 Senice or feeder 600 amps or more 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Desuiption I Qty. I Each I Total I - New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. Tax map/parcel#: 1,000 sq.fl or less 168.54 4 Ea.add'I 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential Installation of 32 panels in 4 arrays on a roof-mounted 12.800kW PV system (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) MI PROPERTY OWNERRenewable Energy See Page 2 0 'TENANT Services or feeders installation, Item ion,and/or relocation Name:Don Cantrell 200 amps or less 100.70 2 Address:12360 SW Aspen Ridge Dr 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard, OR 97224 601 amps to 1,000 amps 301 04 2 Phone:( )503-298-9630 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:donastoria@yahoo.tbm relocation Owner installation: This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125 08 2 Owner signature: _ Date: 401 amps to 599 amps 168.54 2 Branch circuits-new,alteration,or extension, ,er panel O APPLICANT OE CONTACT PERSON A.Fee for branch circuits with Business name:TML International LLC dba Infinty Solar USA above service or feeder fee, 7.42 2 each branch circuit Contact name:Mary Dinsmore-Smith B Fee for branch circuits without 6405 E Mill Plain Blvd service or feeder fee,first Address: branch circuit 56 18 2 City/State/ZIP:Vancouver WA 98661 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( )360-326-0650 Fax::( ) Each manufactured or modular Email:permit@infinitysolarusa.com dwelling,service and/or feeder 67.84 2 Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:TML International LLC dba Infinity Solar USA Sign or outline lighting 6784 2 Address:6405 E Mill Plain Blvd Signal circuit(s)or limited-energy panel,alteration,or extension. CISee Page 2 2 City/State/ZIP:Vancouver WA 98661 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone: ( )360-326-0650 Fax:( ) Investigation(l hr min) 90.00/hr Email:permit@infinitysolarusa.com Industrial plant(I hr min) 78 18/hr Inspections for which no fee is CCB Lie.:223690 Electrical Lic.:C1556 Suprv.Lie.:4434S specifically listed(Y,hr min) 90.00i hr Suprv.Electrician signature,required: �jJ�p ELECTRICAL PERMIT FEES �,9 /W/ i Subtotal Print name:Todd Rouse Date:10/18/2023 0 Plan Review Required(25%of permit fee) State surcharge(12%of permit fee). Authorized signature: 7:)Gj-yLg2.4.-5'1-t TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Mary Dinsmore- ith Date:10/18/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. I.1Bwlding'Permits'ELC PermisApp_ELR_ERE.doe Rev 06/17/2015 440-4615T(11/05/COM/WEB • Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: FEE SCHEDULE f; ,`; : RESIDENTIAL WORK ONLY: Description I Qty. I Each I 'total Fee for all residential systems combined: S75.00 Renewable electrical energy systems: 5 kva or less 100.70 2 Check Type of Work Involved: 5.01 to 15 kva 1 133.56 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 • Vacuum Systems* >I00 kva-no additional charge 0.0 3 ❑ Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25!hr charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(%hr min) ELECTRICAL PERMIT FEES COMMERCIAL WORK ONLY: Subtotal(Enter on Page I). Fee for each commercial system: $75.00 Number of inspections allowed per pernir (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations [1BuildingTermits\ELC_Perm5App_ELR_ERE.doe Rev 06/17/2015 City of Tigard 1114 '' Building Division 13125 SW Hall Blvd,Tigard, OR 97223 RECEIVED Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 OCT 31 2023 www.tigard-or.gov CITY OF TIGARD BUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12360 SW Aspen Ridge Dr City: Tigard Zip: 97224 Owner's Name:Don Cantrell Date: 10/18/2023 Contractor's Name:TML International LLC dba Infinity Solar USA CCB #: 223690 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? No OSSC or ORSC for design requirements. LI Is the wind exposure Yes If"Yes", qualifies for Wind Exposure "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes Q Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ❑ Yes the prescriptive path. above ❑ No 1 C/Building/Forms/Photo Voltaic-Checklist02-01.I I.docx • Is the construction material wood and does ❑� Yes Type of the construction qualify If"Yes", qualifies for Construction as"conventional light ❑ No the prescriptive path. frame" construction? Is the spacing 24 inches or less? If Pre-engineered trusses. ❑■ Yes "Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight • Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ❑■ Yes with Section 305.4(3) of If"Yes", qualifies for ❑ the 2010 Oregon Solar No the prescriptive path. Code? ❑ Metal Single layer If roofing material is RoofingCheck the type of ❑ of wood yp one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ❑■ of composition shingle. Is the roof mounted111 Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for framingblockin ❑ No the prescriptive path. to the roof or g directly'? 2 I_Budding/Forms/Photovoltaic-Checklist02-01-11.docx 1 • ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum #10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. ''V2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members El No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ❑� Yes the prescriptive path. surface. ❑ No 3 1/BuildingfForms/PhotoVoltaic-Checklist02-01-I l.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer:SILFAB Model Number:SIL-400 HC+ Listing Agency: UL 61730 4 k/Building/Fors/PhotoVoltaic-Checklist02-01-I I docx