Permit (142) CITY OF TIGARD MASTER PERMIT
IN -' '
COMMUNITY DEVELOPMENT
Permit#: MST2023-00573
Date Issued: 11/09/2023
T j C.-,A E 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S 09/202 7500
Jurisdiction: Tigard
Site address: 12360 SW ASPEN RIDGE DR
Subdivision: THORNWOOD Lot: 46
Project: Cantrell
Project Description: Rooftop solar PV system. 12.8 kW.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $10,467.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Other Fixtures: 0
Drywall-Trench Drain: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp:
0 W/Svc or Fdr: 0
Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O SvclFdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N
Other: Y Other Description: Rooftop solar array 12.8 kW Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VB R-3 0
Owner: Contractor:
CANTRELL,DONALD P&DENISE L TML INTERNATIONAL LLC Required Items and Reports(Conditions)
12360 SW ASPEN RIDGE DR 6405 E MILL PLAIN BLVD
TIGARD,OR 97224 VANCOUVER,WA 98661
PHONE: PHONE: 800-364-0470
FAX:
Total Fees: $356.19
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law require o follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
Q5911n1_rim n thr inh R 05911111-nnan Vn ' rnnv of tha r„lac nr rlirerl ni meting to r111NR by rallinn SO'i 9'39 1QR7 nr 1 Ann Z'39'n44
0,11
I + •'O Cl
Issued By: Permittee Signature: �� / �' �'L
Call 503.639.• . by 7:00 a.m.for the next available inspection date. !
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Building Permit Application
Residential FOR OFFICE USE ONLY
Received11 Permit No
City of Tigard DECEIVE Date,By: n ti I�ti3. WP NIS12023.00513
• 13125 SW Hall Blvd.,Tigard,OR 9 Plan Review
Phone: 503.718.2439 Fax: 503.598ection ine: -1960 Date/By.. I , • 7`a3 Other Pemut.
Ins L 503.639.4175 OCT 3 2023 Date Ready/By: Saris-. ® See Page 2 for
TIGr\Rl) p
Internet: www.tigazd-or.gov Notified/Method: /1 7)-� I Supplemental Information
CITY OF I C rRD :., 6# am
vc.� '
DTYPEOF iktif DING
D1 ' " 1 REQUIRED 1-AND 2-FAMILY DWELLING
O New construction ❑Demolition in,y4,4 el- Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
0 Addition/alteration/replacement ❑� Other:Solar equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
Valuation: $10467.00
❑� 1-and 2-family dwelling ❑Commercial/industrial
Number of bedrooms:
❑Accessory building 0 Multi-family
Number of bathrooms:
❑Master builder ❑Other.
JOB SITE INFORMATION AND LOCATION Total number of floors.
Job site address:12360 SW Aspen Ridge Dr New dwelling area: square feet
City/State/ZIP:Tigard, OR 97224 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name:Solarinstall-DCantrell Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Lot no_ Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
Tax map/parcel na: equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Installation of 32 solar panels in 4 arrays on a roof-mounted 12.800kW PV System Valuation: S
Existing building area: square feet
New building area: square feet
0 PROPERTY OWNER 0 TENANT Number of stories:
Name:Don Cantrell Type of construction:
Address:12360 SW Aspen Ridge Dr Occupancy groups.
City/State/ZIP'Tigard, OR 97224 Existing:
Phone I )503-298-9630 Fax:( ) New.
UI APPLICANT 0 CONTACT PERSON BUILDING PERMIT FEES*
(Please refer to fee schedule)
Business name:TML International LLC dba Infinity Solar USA Structural plan review fee(or deposit):
Contact name:Mary Dinsmore-Smith
FLS plan review fee(if applicable):
Address:6405 E Mill Plain Blvd
Total fees due upon application:
City/State/ZIP:Vancouver,WA 98661
Amount received:
Phone:( )(360)326-0650 Fax: : ( )
-
Pl1OTOVOLTAIC SOLAR PANEL SYSTEM FEES*
F-mail:permit@infinitysolarusa.com
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Business name:TML International LLC dba Infinity Solar USA Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:6405 E Mill Plain Blvd Solar Installation Specially Code checklist.
City/State/ZIP:Vancouver,WA 98661 Permit Fee(includes plan review $180.00
7 and administrative fees):
Phone:( )360-326-0650 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB Sic.:223690 Total fee due upon application: $201.60
Authorized signature: e/ This permit application expires if a permit is not obtained
D2,�^�{'12LllG within 180 days after it has been accepted as complete.
*Fee methodology set by Tr;-County Building Industry
Print name:Mary Dinsmore- mith Date:10/18/2023 Service Board.
I.\Building\Permits 1BUP-RESPermitApp.doc 02/24/2011 440-4613T(I1/02/COM/WEB)
electrical Permit Application FOR OFFICE USE ONLY
City of Tigard CEIVE Received MS1�2 11G
nn Date/By. Perntit k:
• 13125 SW Hall Blvd.,Tigard,OR 9'/t : 3 5�3
Pril
$ �� Plan Review
Phone: 503.718.2439 Fax. 503.59 1 Date,By Related Permit 6:
Inspection Line: 503.639.4175 Read Date/Byloci,..
TIGARD rr'* - 7(t'J9 Y ' H See Page2for
Internet wwnv.tlgard-or.gov tJL.) Notified,Method Supplemental Information
TYPE OF WORK . ....,, PLAN REVIEW
0 New construction Q Addition/alteration/replacement Plcasc check all that apply(submit 2 sets olplans wiitems checked):
❑ Demolition El Other: Solar 0 Service or feeder 400 amps or more 0 Building over three stories.
where the available fault current 0 Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
ID1-and 2-family dwelling ['Commercial/industrial ❑Accessory building less to ground.or exceeds 14,000 ❑Commercial-use ag cultural
amps for all other installations. buildings.
❑Multi-family E Master builder ❑Other: ❑Fire
pump. 0 Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived
Job#: Job site address:12360 SW As en Rid a Dr 0 Addition of new motor load of system.
P 9 1001-IP or more. ❑"A","E","1.2","1-3",
City/State/ZIP:Tigard, OR 97224 0 Six or more residential units_ occupancy.
❑Health-care facilities_ 0 Recreational vehicle parks_
Suite/bldg./apt.#: Project name:Solarinstall-DCantrell 0 Hazardous locations. 0 Supply voltage for more than
0 Senice or feeder 600 amps or more 600 volts nominal.
Cross street/directions to job site: FEE SCHEDULE
Desuiption I Qty. I Each I Total I -
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
Tax map/parcel#: 1,000 sq.fl or less 168.54 4
Ea.add'I 500 sq.ft.or portion 33.92 1
DESCRIPTION OF WORK Limited energy,residential
Installation of 32 panels in 4 arrays on a roof-mounted 12.800kW PV system
(with above sq.ft.) 75.00 2
Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
MI PROPERTY OWNERRenewable Energy See Page 2
0 'TENANT Services or feeders installation, Item ion,and/or relocation
Name:Don Cantrell 200 amps or less 100.70 2
Address:12360 SW Aspen Ridge Dr 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard, OR 97224 601 amps to 1,000 amps 301 04 2
Phone:( )503-298-9630 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email:donastoria@yahoo.tbm relocation
Owner installation: This installation is being made on property that I own which is not 200 amps or less 59.36 I
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125 08 2
Owner signature: _ Date: 401 amps to 599 amps 168.54 2
Branch circuits-new,alteration,or extension, ,er panel O APPLICANT OE CONTACT PERSON
A.Fee for branch circuits with
Business name:TML International LLC dba Infinty Solar USA above service or feeder fee, 7.42 2
each branch circuit
Contact name:Mary Dinsmore-Smith B Fee for branch circuits without
6405 E Mill Plain Blvd service or feeder fee,first
Address: branch circuit 56 18 2
City/State/ZIP:Vancouver WA 98661 Each add'l branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:( )360-326-0650 Fax::( ) Each manufactured or modular
Email:permit@infinitysolarusa.com
dwelling,service and/or feeder 67.84 2
Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name:TML International LLC dba Infinity Solar USA Sign or outline lighting 6784 2
Address:6405 E Mill Plain Blvd Signal circuit(s)or limited-energy panel,alteration,or extension. CISee Page 2 2
City/State/ZIP:Vancouver WA 98661 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone: ( )360-326-0650 Fax:( ) Investigation(l hr min) 90.00/hr
Email:permit@infinitysolarusa.com Industrial plant(I hr min) 78 18/hr
Inspections for which no fee is CCB Lie.:223690 Electrical Lic.:C1556 Suprv.Lie.:4434S specifically listed(Y,hr min) 90.00i hr
Suprv.Electrician signature,required: �jJ�p ELECTRICAL PERMIT FEES
�,9 /W/ i Subtotal
Print name:Todd Rouse Date:10/18/2023 0 Plan Review Required(25%of permit fee)
State surcharge(12%of permit fee).
Authorized signature: 7:)Gj-yLg2.4.-5'1-t TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
Print name:Mary Dinsmore- ith Date:10/18/2023 days after it has been accepted as complete.
* Number of inspections allowed per permit.
I.1Bwlding'Permits'ELC PermisApp_ELR_ERE.doe Rev 06/17/2015 440-4615T(11/05/COM/WEB
•
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
FEE SCHEDULE f; ,`; :
RESIDENTIAL WORK ONLY: Description I Qty. I Each I 'total
Fee for all residential systems combined: S75.00 Renewable electrical energy systems:
5 kva or less 100.70 2
Check Type of Work Involved:
5.01 to 15 kva 1 133.56 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
❑ Garage Door Opener* >100 kva(fee in accordance
552.26 2
with OAR 918-309-0040)
❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
•
Vacuum Systems* >I00 kva-no additional charge 0.0 3
❑
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25!hr
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed(%hr min)
ELECTRICAL PERMIT FEES
COMMERCIAL WORK ONLY: Subtotal(Enter on Page I).
Fee for each commercial system: $75.00 Number of inspections allowed per pernir
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
[1BuildingTermits\ELC_Perm5App_ELR_ERE.doe Rev 06/17/2015
City of Tigard
1114 '' Building Division
13125 SW Hall Blvd,Tigard, OR 97223 RECEIVED
Phone: 503.718.2439 Fax: 503.598.1960
TIGARD Inspection Line: 503.639.4175 OCT 31 2023
www.tigard-or.gov
CITY OF TIGARD
BUILDING DIVISION
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 12360 SW Aspen Ridge Dr
City: Tigard Zip: 97224
Owner's Name:Don Cantrell Date: 10/18/2023
Contractor's Name:TML International LLC dba Infinity Solar USA CCB #: 223690
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? No OSSC or ORSC for
design requirements.
LI
Is the wind exposure Yes If"Yes", qualifies for
Wind Exposure "C"or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes Q Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
If"Yes", qualifies for
structures other than
❑ Yes the prescriptive path.
above ❑
No
1
C/Building/Forms/Photo Voltaic-Checklist02-01.I I.docx
•
Is the construction
material wood and does ❑� Yes
Type of the construction qualify If"Yes", qualifies for
Construction as"conventional light ❑ No the prescriptive path.
frame" construction?
Is the spacing 24 inches
or less?
If
Pre-engineered trusses. ❑■ Yes "Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. ❑ If"Yes", qualifies for
Yes the prescriptive path.
❑ No
Is the combined weight • Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance ❑■ Yes
with Section 305.4(3) of If"Yes", qualifies for
❑
the 2010 Oregon Solar No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
RoofingCheck the type of ❑ of wood
yp one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
❑■ of composition
shingle.
Is the roof mounted111 Yes
Connections of solar assembly
the solar assembly connected to roof If"Yes", qualifies for
framingblockin ❑ No the prescriptive path.
to the roof or g
directly'?
2
I_Budding/Forms/Photovoltaic-Checklist02-01-11.docx
1 •
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
❑ If"Yes", qualifies for
Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
prescriptive path.
standing seam
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum #10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. ''V2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members El No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof ❑� Yes the prescriptive path.
surface. ❑ No
3
1/BuildingfForms/PhotoVoltaic-Checklist02-01-I l.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan
Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer:SILFAB
Model Number:SIL-400 HC+
Listing Agency: UL 61730
4
k/Building/Fors/PhotoVoltaic-Checklist02-01-I I docx