Permit (136) CITY OF TIGARD MASTER PERMIT
� PermitfR: MST2023-00541
i COMMUNITY DEVELOPMENT Date Issued: 11/06/2023
T I GA R.0 13125 SW Flail Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S112BA03200
Jurisdiction: Tigard
Site address: 14070 SW 80TH CT
Subdivision: WAVERLY MEADOWS Lot: 22
Project: Sandlin
Project Description: Rooftop solar system 6.0 kW.
BUILDING
Floor Areas
Required Setbacks Required
0
0 sf Basement 0 sf Left: 0 Parking Spaces.
Stories: 0 Bedrooms: 0 First: Smoke
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0
Dwelling Units: 0 Third: 0 sf
Right: 0 Detectors'.
Total: 0 sf Value: E14,360-00 Rear: 0
PLUMBING
0 Rain Drain: 0 Urinals: 0
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays:0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer 0
0 Floor Drains:
Lavatories: 0 Dishwashers: Catch Basins: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker. 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0
Drywell-Trench Dram: 0 Other Fixture Units:
MECHANICAL
Fuel'Noes Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents:
0 Woodstoves: 0 Gas Outlets: 0
Fum>=100K: 0
ELECTRICAL
Residential Unit
Service Feeder Temp Srvc/Feeders Branch Circuits
0 0-200 amp: 0 W/Svc or Fdr: 0
1000 sf or less: 0 0-200 amp: 0 W/O Svc/Fdr: 0
Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp:
Mfd Home/Feeder/Svc: 0 401-600 amp:
0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+ampNolt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
N Vaccuum System: N Garage Opener: N All
N
Audio&Stereo: N HVAC: N Security Alarm: Ecompasing
Other. Y Other Description: Roof top solar array 6.0 kW
BUILDING INFO
Class of Work: Type of Use: Type of Constr:
Occupancy Group: Square Feet:
SF VB
R-3 0
OTR
Owner: Contractor: Required Items and Reports(Conditions)
SANDLIN,JAN K TRUST EARTHLIGHT TECHNOLOGIES LLC
BY JAN SANDLIN TR 812 MCCLAINE ST
14070 SW 80TH CT SILVERTON,OR 97381
TIGARD,OR 97224
PHONE: PHONE: (860)871-9700
FAX:
Total Fees: S351.19
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not staedwithin
t 180
80days
ofn Center. Tho, or se f work is susptended
forth for more
OAR
the 180 days. ATTENTION: Oregon law requires o follow the rules adopted by Oregony
oc,nM-nnt0 rhrnun P oc9-Mi-neon V i `nnu of the r,,I nr direr+nuoegnna+n ni WC by nallinn SM 9:10R7 nr t AMA Rig 94Ad\
�J�G f.C'4C old
Issued By: ---, Permittee Signature:
Call 503.639.4175 by 7:00 a.m.for the next available Inspection date.
This permit card shall be kept Ina conspicuous place on the Job site until completion of the project.
Approved plans are required on the lob site at the time of each Inspection.
I.
Building Permit Application RECEIV 3
Residential FOR OFFICE USE ONLY
9 202 Received perms
City of Tigard OCT � Dater'By:�O 'Gi � �+4A-aQ;*—t4:35511
t q 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Z3 I��'r ether Perms[
I, I/ Phone: 503.7182439 Fax: 503.598.1960 CITY OFTIGARII a[e,le 1� Z y' L t
I ,c ReadylRy: Z a ��yyy Jwis. S See Page l for
TIGARD Inspection Line: 503.639.4175 BUILDING DIVISI/Lntificd/Mcthod: 1 !I 4?-3 $7: I Supplemental information
Internet wa w.tigard-or.gov r1 _ ;Z�44,,1
TYPE OF WORK
REWIRED DATA:I-AND 2-FAMILY DWELLING
=Permit fees*are based on the value of the work performed.
❑Now constntcuon _ ❑Demolition Indicate the value(rounded to the nearest dollar)of all
❑Addition/alteration/replacement ®Other:Prescriptive Solar equipment,materials,labor,overhead,and the profit for the
work indicated on this application.
CATEGORY OF CONSTRUCTION Valuation: $14360
® I-and 2-family dwelling ❑Commcrcial/industrial
Number of bedrooms:0
❑Accessory building 0 Multi-family
Number of bathrooms:0
❑Master builder ❑Other-
JOB SITE INFORMATION AND LOCATION
Total number of floors:0
New dwelling area:n square feet
Job site address:14070 SW 80th Ct
Garage/carport area: 0 square feet
Ciry/State/z1P:Tigard OR 97224
Suite/bldg./apt.no.: Project name:Sandlin-6.000kWp Solar Covered porch area: 0 square feet
Cross street/directions to job site:
Deck area: 0 square feet
Other structure area: 0 square feet
TtEQV RED DATA:COMMERCIAL-USE CHECKLIST
Lot no.: Permit fees*arc based on the value of the work performed.
Subdivision: Indicate the value(rounded to the nearest dollar)of all
Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the
�r 1 ''S "'kawx�k rF°v-, ,„�. .,�;,�, work indicated on this application.
^ �� Valuation: $
Prescriptive path roof mounted installation of a 6.000kWp solar system Existing building area: square feet
- - New building area: square feet
r 0 PROPERTY OWNER { 0 TENANT . Number of stories:
I
Type of construction:
Name: —. -- - —.
Address: _ Occupancy groups:
City/State/ZIP: _ Existing.
Phone:( ) Fax:( 1 New:
tt
Ei APPLICANT 0 CONTACT PERSON BUILDING PERMIT FEES* —�
(Please refer to fee schtdrle).
Business name. Earthlight Technologies LLC Structural plan review fee for deposit):
Contact name: Fliz beth Winslow FLS plan review fee(if applicable):
Address: 812 McClaine Rd _ - Total fees due upon application:
City/State/ZIP: Silverton, OR 97381 Amount received:
Phone ( 503) 874-4142 Fax::( )
Mg lace ,4° ,. PAN y T, FEES*
E-mail or�ertfll S�yeadhi. htterh cflf'rj Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted Photovoltaic Solar Panel System.
Submit two(2)sets of roof plan with connection details
Business name: Earthlight Technologies LLC and fire department access,along with the 2010 Oregon
Address: 812 McClaine Rd Solar Installation Specialty Code checklist.
plan review $180.00
City/State/ZIP: Silverton, OR 97381 Permit Fee(includes end administrative fees):
Phone:( 503) 874-4142 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lie.: 201408 Total fee due upon application: $201.60
� I
Authorized signature: ^ I. (�(f This permit application expires if a permit is not obtained
• t W(� within 180 days after it has been accepted as complete.
10116/2023 I Fcc methodology set by Tri-County Building Industry
Print name: Elizabe� Winslow Date: Service Board.
1:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
J.
Building Permit Application Checklist
One- and Two-Family Dwelling FOR OFFICE USE ONLY
City of Tigard Received
p 13125 SW Hall Blvd.,Tigard,OR 97223
Date/By:
503.718.2439 Fax: 503.598.1960 Associated permits: Puma Nu.:
TIGARD 24-Hour Inspection Line: 503.639.4175 0 Electrical 0 Plumbing 0 Mechanical
Internet: www.tigard-or.gov ❑ Other
THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW ves No NIA
' I Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑
2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ ❑ lil
3 Verification of approved plat/lot. ❑ ❑ it
4 Fire district approval required. Name of district: ❑ ❑
5 Septic system permit or authorization for remodel. Existing system capacity . ❑ 0
6 Sewer permit. ❑ 0
l
7 Water district approval. 0 ❑ -
8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ 0 In
9 Erosion control ❑plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ ii
basin protection,etc.
10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state 1SI 0 ❑
building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size
sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed(f
copyright violations exist.
1 I Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if 0 0
there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft. intervals);location of easements
and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction
indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and
surface drainage.
12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ 0
and location.
13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ 0
furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc.
J 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑
floor,wall construction,roof construction. More than one cross section may be required to clearly portray
construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings
and foundation,stairs,fireplace construction,thermal insulation,etc.
15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ 0
Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope.
Full-size sheet addendums showing foundation elevations with cross references are acceptable.
16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ ❑
prescriptive path analysis provide specifications and calculations to engineering standards.
17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ 0
locations. Show attic ventilation.
18 Basement and retaining walls. Provide cross sections and details showing placement of rehar. For engineered ❑ ❑
systems,see item 22,"Engineer's calculations."
19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ Hi
over 10 feet long and/or any beam/joist carrying a non-uniform load.
20 Manufactured floor/roof truss design details. LI ❑ i
21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ El 0
for four or more appliances.
22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ 0
architect licensed in Ore on and shall be shown to be a..licable to the rro'ect under review.
JURISDICTIONAL SPECIFICS
23 Three(3)site plans are required for item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 0
24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ ❑
25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 0 0
26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. El ❑
27 "Drawn to scale"indicates standard architect or engineer scale. 0 ❑
28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ '
Street Tree List.
29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, 0 ❑
and protection measures must be drawn to scale and must include the project arborist's signature of approval.
30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ 0 El
including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings
on a lot of record approved prior to September 9,1995.
L1Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
e • RECEIVED
OCT 19 2023 FOR OFFICE,USE ONLY
Electrical Permit Application aM�i7A -'0 V
/� OF TIGARD R�ReceivedPermit 3
City of Tigard CITY Received
IN4 13125 SW Hall Blvd.,Tigard,OR 97223 (BUILDING DI ISIO' Plan Review Related Permit it:
C: Phone: 503.718.2439 Fax: 503.598.196 Date/By: sela ® See Page 2 for
TIGARD Internet.
www tigard or-gov Ready DateBy:Line: 503.639.
Inspection Notified/Method: _ I Supplemental Information
ov
TYPE OF WORK
I S PLAN REVIEW
Pleae heck all tl u+t..In y f;cb:rh 2 �t,of ptens n,tam 1 ocked)
0111
Addition/alteration/replacement ❑Building over Inure stories.
New constructioner ❑Sem me or tether 400 amps or more
�f0[her: Solar where the available fault current 0 Marinas and boatyards.
E Demolition exceeds 10,000 amps at 150 volts or 0 Floating buildings
less to ground,or exceeds 14,WU ❑ -
CATEGORY OF CONSTRUCTION Commercial-use agricultural
❑ Accessory building amps for all other installations. buildings
t�l-and2-family dwelling ❑C'ummctuaLtndustrial❑Multi-family ❑ Master ❑[nstauatinnoYlSotcvAnr
❑Other: El Fire pA Cr larger separately derived
❑Emergency system.
JOB SITE TNFORMATITTON AND LOCATION 0 Addition of new motor load of system
_._ 14070 SW 80th Ct IOOHP or mom.
Job#: Job site address: c ancy
,,l OR (� ❑Six It more residential unite. ❑ocRecreationalp vehicle parks.
City/State/ZIP: Tigard 97224 _ ❑Health-care facilities. oe
❑hazardous locations ❑Supply voltage for more than
Project name: Sup volts stage fo
saite/bldg./apt.#: ( i Sandlin 6.000kWp solar ❑Sen lei or tccdcr ell amps o.roof
FEE SCHEDULE
Cross street directions to job site: Dexeripv m I ()Iv:I, Each I Total I .
New residential single-or multi-family dwelling unit.
Lot#: Includes attached garage.
1,000 sq.ft.or less
Subdivision: 168.54 4
Tax map/parcel#: Ea.add'I 500 sq.ft or portion
33.92 I
DESCRIPTION OF WORK Limited energy,residential 75.00 2
Prescriptive path roof mounted installation of a 6.000kWp solar (with aboveLimited energy,multi-family 75.00
2
residential(with above sq.ft.)
System Renewable Energy El See Page 2
7 0 PROPERTY 0 T
OWNER I "FEN -. Services le feeders installation,alteration,and/or relocation 2
200 amps or less 100.70
Name: -- 201 amps to 400 amps 133.56 2
Address:
401 amps to 600 amps 200.34 2
601 amps to 1,000 amps 301.04
2
City/State/ZiP: — 552.26 2
Phone:( ) Fax:( ) Over 1,000 amps or voltsTemporary services or feeders installation,alteration,and/or
relocation
Email: 200 amps or less 59.
Owner installation:This installation is being made on property that i own which is not 19.36 6 2
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps
Date, 401 amps to 599 amps
)6R.54 2
Own or signature:_ — ^.,'qF Branch circuits-new,alteration,or extension, .er panel
N APPLICANT ,.I. CONTACTEl PERSON .i>-. A.Fee for branch circuits with
above service or feeder fcc, 7.42 2
Business name: Earthllght Technologies LLCeach branch circuit
Elizabeth Winslow B Fee for branch circuits without
Contact name: service or feeder fee,first 56-I8 2
City/StatelZiP: SIIVeftOn, OR 97381
812 McClaine St branch circuit 2
Address: Each add'1 branch circuit 7.42
Miscellaneous(service or feeder not included)
Each manufactured or modular 67 84 2
Phone:(503) 874-4142 Fax::( ) dwelling,service and/or feeder
FinaiC orpermits • cart ig ec .tom67.84 2
Reconnect service
CONTRACTOR Pump or irrigation circle
67.84 2
-
Sign or outline lighting 67.84 2
Business name: Earthlight Technologies LLC Signal circuitis)or limited-energy ❑ See Page 2 2
812 McClaine St panel,alteration,or extension.
Address: Each additional inspection over allowable in any of the above
City/State/ZIP: Silverton, OR 97381 __ —
Additional inspection(I hr min) 66.25/hr
Investigation(I hr min) 90.00/hr
Phone:(503 )87k-4142 � Fax:( ) 78.t81 hr
Industrial plant 0 hr min)
Email: orpermits@earthlighttech.com inspections for which no fee is 9000,hr
4567S peciuca�ly hs[cdL ELECTRICAL
CCB Lic.: 201408 Electrical Lie.: C995 Suprv.Lie.: CTRICAL PERMIT FEES
a>
T ,A Subtotal.
Suprv.Electrician signature,required: L .FQ �-
"t"'""'� 1011612023 ❑Plan Review Required(25%of permit fee):
t I Date:
Print name: Timothy Schnieder State surcharge(12%of permit fee):
�� I ���,, •ems, TOTAL PERMIT FEE:
l I I tN IifIA�U
Authorized signature: t I This permit application expires if a permit It is not obtained within IRO
r 1011612023 days after it has been accepted as complete.
Print name: Elizabeth Winslow Date: * Number of inspections allowed per permit.
19nuilding\Pcrmns\F.LC_Pcrmitnpp_F.LR FRF_duc Rev 06/I720I5
640-4615T(I1/)5/COM/WF.B
r
•
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
....� FEE SCHEDULE
RESIDENTIAL WORK ONLY: Description ot,.- Ruch
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
5 kva or less 100.70 2
Check Type of Work Involved:
5.01 to 15 kva 1 133.56 2
❑ Audio and Stereo Systems* 15,01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
El Garage Door Opener* >100 kva(fee in accordance
with OAR 918-309-0040) 552.26 2
❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva-no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
I Other: Each additional inspection is 66?5Ihr
charged at an hourly(I hr min)
Inspections for which no Ice is 90.001 hr
s.ecificall listed('/hr min)
COMMERCIAL'WORK ONLY: --
Subtotal(Enter on Page I)_
Fee for each commercial system: $75.00 * Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
n Audio and Stereo Systems
I Boiler Controls
n Clock Systems
n Data Telecommunication Installation
❑ Fire Alarm Installation
I-I HVAC
❑ Instrumentation
❑ intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
n Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I.\Buitdine\Permits\ELC_Permi[App_EI.R F.RE..doc Rcv 05/17/2015
Prescriptive Solar Photovoltaic InstallatiftWEIVECI
2019 Oregon Structural Specialty Code (OSSC) OCT 1 9 2023
%.' Compliance CITY OF TIGARD
BUILDING DIVISION
Use this checklist to demonstrate compliance with the prescriptive photovoltaic(PV)requirements of Sections
3111.3.5.3 and 3111.3.4.8 of the Oregon Structural Specialty Code(OSSC). Separate electrical permits are required for
the installations.
PART I— PROPERTY OWNER INFORMATION
Property owner name:Jan Sandli n Phone number:541-915-8797
Installation address: 14070 SW 80th Ct
city:Tigard I State: Oregon ZIP:97224
Structure on which modules are to be installed:Roof
Installer: ❑■ Contractor ❑ Owner(if owner, skip to Part 111)
PART II—CONTRACTOR INFORMATION
Contractor name: Earthlight Technologies LLC Phone number:503 874 4142
Email address:OregonOps@EarthlightTech.com
BCD business license#:C995 I Contractor's CCB#:201408
PART III—STRUCTURAL CRITERIA
Roof structure requirements
If"No"is selected for any item below, or if the supporting structure is a manufactured dwelling, the project may not be
submitted using the prescriptive path.
Check the appropriate boxes for each item as it applies to the project.
• Structure is classified Risk Category i or II in accordance with OSSC 1604.5: ❑■ Yes ❑ No
• Structure is of conventional light frame construction: Q Yes ❑ No• Supporting roof framing is one of the following: El Yes E No
(check one) ❑■ Pre-engineered trusses spaced<_24 inches o.c.;or
❑ Rafters spaced<_24 inches o.c.and spans comply with OSSC 2308.7.2 or ORSC R802.5,respectively
• Ground snow load does not exceed maximum load: ■❑ Yes ❑ No
(check one) ❑ <50 psf for structures under the ORSC,or ❑ <_70 psf for structures under the OSSC
• The basic design wind speed does not exceed the following: Q Yes ❑ No
(check one) i] <_ 120 mph in Wind Exposure Category C for structures under the OSSC;or
❑ < 135 mph in Wind Exposure Category B for structures under the OSSC;or
❑ < 135 mph in Wind Exposure Category C for structures under the ORSC
• Roofing materials are metal,single-layer wood shingle or shake, or
not more than two layers of composition shingle: • Yes E No
• Module height is less than 18 inches from the top of the module to the roof surface and
complies with Figures 3111.3.5.3(1)and 3111.3.5.3(2): ❑� Yes ❑ No
�++ Buil
ding
• (o°:on Published by Building Codes Division—Aug. 18, 2021
Department al Consumer
and Business Services
PART III— STRUCTURAL CRITERIA(continued)
Loading requirements
Check the appropriate boxes for each item associated with the selected attachment method.
■❑ Attachment 1: PV modules or racking is attached directly to the roof framing or blocking:
• Combined weight of PV modules and racking is not more than 4.5 psf: UI Yes ❑ No
• Spacing of PV modules or racking complies with one of the following: 0 Yes ❑ No
(check one) I <48 inches in any direction;or
❑ <24 inches in any direction where the following are true:
• Ground snow load is more than 36 psf
• Panels are located within 3 feet of a roof edge,hip,eave,or ridge
• Basic design wind speed is greater than 120 mph in Wind Exposure Category B
• Basic design wind speed is greater than 110 mph in Wind Exposure Category C
*If this is the appropriate attachment method and "No" is selected,for any of the items above, the project may not
be submitted using the prescriptive path.
❑ Attachment 2: PV modules or racking is attached directly to standing seam metal panels:
• Combined weight of PV modules and racking is not more than 4.5 psf: ❑ Yes ❑ No
• Clamps comply with the following requirements:
• Provide the following, allowable uplift capacity: ❑ Yes ❑ No
(check one) ❑ Not less than 115 pounds and spaced at 60 inches o.c.or less;or
❑ Not less than 75 pounds and spaced at 48 inches o.c.or less.
• Spacing between metal panel seams is not more than 24 inches ❑ Yes (— No
• Spacing along a metal panel seam is not more than 60 inches ❑ Yes ❑ No
• Metal roofing panels comply with the following requirements:
• Panel thickness is 26 gauge steel,minimum ❑ Yes ] No
• Panel width is 18 inches or less ❑ Yes ❑ No
• Attached with at least#10 screws at 24 inches o.c. ❑ Yes ❑ No
• Installed over minimum 1/2-inch nominal wood structural panels attached to framing
with Rd nails at 6 inches o.c. at panel edges and 12 inches o.c. field nailing ❑ Yes ❑ No
*If this is the appropriate attachment method and "No"is selected for any of the items above, the project may not
be submitted using the prescriptive path.
-NAP ,Vira
PART IV—ROOF DESIGN SITE PLAN
Roof design requirements
• Attach a simple structural plan showing the roof framing(rafter size,type,and spacing)and PV system racking
attachment.
• System must be shown in sufficient detail to assess whether the requirements of Section 3111.3.5.3 have been met.
• The structural plan must be on 8.5-inch x 11-inch or larger paper.
PART V— PV MODULES
Manufacturer:Sunpower
Model number:SPR-U-400-BLK-W-DC
Listing agency:UL
[2]
PART VI — PATHWAYS AND CLEARANCES
Pathway and clearance requirements
• Using the grid below or an attached 8.5-inch x 11-inch or larger paper,provide a simple drawing,indicating the
location of the PV system in relation to buildings,structures,property lines,and,as applicable,flood hazard areas.
• The drawing must be shown in sufficient detail to assess whether the pathway requirements of Section 3111.3.4.8 or
one of the exceptions have been met.
[3]