Loading...
Report (15) • Ivf 25023 — 06)211 !T1S3 S+� C6s t�, G /She r��c� • ftV 5 . FIELD REPORT Page 1 of l Project: NewHome-5-02 Prepared By: Inna Gergalo Project Name: River Terrace Town Center Date: 10/24/23 Location: SW Roy Rogers Road Report#: 126 Tigard, Oregon Arrival: 1 100 Departure: 1 145 Weather: Rainy, 60s Permit#: Site Visit Requested By: Frank (New Home) Met With (on-site): Frank (New Home), Elite Excavation crew Purpose: Lot Subgrade Outstanding Issues: Lot Subgrade Upon arrival, I evaluated the subgrade for lots 78 and 94. I probed the exposed subgrade using a%2-inch- diameter steel foundation probe. Exposed subgrade visually consisted of brown silt covered by approximately 2-3 inches of%"-0 crushed rock. Resulting penetrations indicated the exposed subgrade at probed locations is medium stiff to stiff. Storm/Sanitary Trench Backfill Elite Excavation crew informed me that they placed approximately 24" of%"-0 crushed rock to backfill the storm and sanitary trench for Lot 78. The crushed rock was sourced from Knife River (Farmington) and compaction was done via large diesel plate. I used a Troxler 3430 nuclear density gauge to evaluate compaction. Density tests were compared to a proctor value of 127.2 pcf at an optimum moisture content of 11.5%, determined in our soil lab in general accordance with ASTM D1 557. Tested location met the minimum compaction recommendations. Conclusion Based on our observations, density testing, and probing, it is our opinion that subgrade and trench backfill observed today, as indicated on the attached site plan, have been prepared in general accordance with project requirements and our geotechnical recommendations. Distribution: Attachments: Site plan (1), NDGD(1) Reviewed by: This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services.We rely on the contractor to comply with the plans and specifications throughout the duration of the project irrespective of the presence of our representative. Our work does not include supervision or direction of the contractor,the contractor's employees or agents. Our firm is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations. The report can only be considered final upon review of the NVS project manager,as indicated by initials in the"Reviewed By"section. /, , D Signature: 9450 SW Commerce Circle,Suite 300 I Wilsonville ,OR 97070 1503.968.8787 I www.nv5.com NewHome-5-02 FR-126 10/24/2023 saw = Lot Subgrade Observed 1 ^ mii = Sanitary/Storm Trench Backfill --.,, 1 � R� ► Areas / locations are approx. - not to scale � � 1 1 i _ 1 , I V f OP. „s,m[i T / / �� �� — REVISIONS i3 NO ORTE DESCRIPTION ' I I / -' LEGEND / 1 I I % \ 1 ` j b awl ". IT C0100. SITI.TO. 1 / `1 �� 1i/ ✓ k' camp• f / / f ED s g CUM.Lunrrs / / / 1 n - Lam "11 /J -� ../ '�F a •-.!�IL. ,GENERAL NOTES. . .,, .,. —_ ICI n[e NC'iOM -o p / 4 1 # ,.T . iri . — f�LI / ' 1 ( / ' / (. pis v _' , ;— ,,[ / �' i I / 2 ,oON TO we., ae RIVER / / j - ,�_`:.. ,.w. .o ems.m ■ TERRACENT I f I '` r —1 1 1 - . TOWNER s ,.' � 'C It 1 III 1 1 IN i It /, ewt -�. OVERALL GRADING //.• .. _ PLAN /(/C ' .''�,! III , it aii "I \ 9e . oz $ \ /. � SGR 1 l ..,,, a u „ p 109 a it i A c i NV 5 NUCLEAR DENSITY GAUGE DATA • Project: NewHome-5-02 Project Name: River Terrace Town Center Date: 1 0/24/2023 Sampled By: ipg Project Location: SW Roy Rogers Rd, Tigard, Oregon Material Source Maximum Density: pcf(required) Optimum Moisture A Import Silt - River Terrace Dev. A 1 1 3.9 pcf(ASTM DI 557) A 14.2% B 3/4"-0 C.R. (Farmington.) B 1 27.2 pcf(ASTM D1557) B 11.5% C 3/4"-0 C.R. (Farmington.) C 122.1 pcf(ASTM D698) C 11.4% *Depth to final grade (ft) Test Date Location Elevation* Fill Type Compactor Density % Moisture No. Maximum Required 1 10/24 Storm/Sanitary Trench Backfill - see site plan 0 B Diesel plate 125.0 8.0 98% 95% Page 1 of 1