Loading...
Permit (134) CITY OF TIGARD MASTER PERMIT 111 ° COMMUNITY DEVELOPMENT Permit#: MST2023-00536 T I GAR r) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 1 0131/2 0 2 3 Parcel: 2S104AD02000 Jurisdiction: Tigard Site address: 12605 SW 128TH AVE Subdivision: BELLWOOD Lot: 47 Project: Lu Project Description: Rooftop solar system 13.12 kW. BUILDING Floor Areas Required Setbacks Recurred Stories: 0 Bedrooms: 0 First: 0 sl Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right 0 Detectors: Total: 0 sf Value: $23,500.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: Storm Sewer; 0 Tubs/Showers: 0 Garbage Disp: 0 Water Healers: 0 0 g P Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywall-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heal Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp 0 W/Svc or Fdr: 0 Ea addl 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O SvrJFdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N SecurityAlarm: N Vaccuum System: N Garage Opener N All Other: V Other Description: Roof top solar array 13.12 kW N Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr. Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: LU,RANDY S&LORNA K SUNPATH SERVICES LLC Required Items and Reports(Conditions) 12605 SW 128TH AVE PO BOX 751 TIGARD,OR 97223 CANBY,OR 97013 • PHONE: PHONE: 503-313-7253 FAX: Total Fees: $351.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law re s you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR o52nnl-onto 1hr .h nap oca_nn1-nnon v nhla;n a rnnv of tha ndee nr dirart nuectinne 1n cm ikir by rollinn RCM 949 1 ga7 nr 4 Ann'119 9zdd n Issued By: /6 474 /i Permittee Signature: `J e.- -79j7 I t c«.74 f D V\ Call 503. .4175 by 7:00 a.m.for the next available Inspection date. This permit card shall pt in a conspicuous place on the Job site until completion of the project Approved plans are required on the job site at the time of each inspection. • Building Permit Applicatio ECEIVED Residential FOR OFFICE USE ONLY Cityof Tigard6 2023 Received 131 SW Hall Blvd.,Tigard,OR 972230 OCTC T PlPlan Review I �liir Perin i ����I ✓ tt� : 503.718.2439 Fax: 503.598.t�¢�. Date/By d l7ther Permit: TIi ,�it Inspection Line: 503.639.4175 GI I Y OF TIGARD Date Ready/By: Avis: ® See Page 4 for Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method: ' ;I ?j.Or Supplemental Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ®✓ Other: Solar equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ✓ 1-and 2-famil y dwellin Valuation: $23,500 g ❑Commercial/industrial ElAccessory building El Multi-familyNumber of bedrooms: ❑Master builder ❑Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 12605 SW 128th Ave New dwelling area: square feet City/State/ZIP: Tigard, OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:Solar— Randy Lu Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work perfonned. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of a roof-mounted 13.12kW PV System Valuation: S Existing building area: square feet New building area: square feet D PROPERTY OWNER I ❑ TENANT Number of stories: Name:Randy Lu Type of construction: Address: 12605 SW 128th Ave Occupancy groups: City/State/ZIP: Tigard, OR 97223 Existing: Phone:(503 )-840-4514 Fax:( ) New: 151 APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* (Reese refer to jee schedule) Business name:Sunpath Services — - -- Structural plan review fee(or deposit): Contact name: Maggie Ludden FLS plan review fee(if applicable): Address: 9978 SW Arctic Dr Total fees due upon application: City/State/ZIP:Beaverton, OR 97005 Phone:(907 ) 792-9290 Fax::( ) Amount received: E-mail: maggie@sunpathservices.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACT a �';' .:;,.. Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name:Sunpath Services Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address: 9978 SW Arctic Dr Solar Installation Specialty Code checklist. City/State/ZIP: Beaverton,OR 97005 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(907 )792-9290 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lid:235715 Total fee due upon application: S201.60 Authorized signature: This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Maggie Ludden Date: 10/16/23 *Fee methodology set by Tri-County Building Industry Service Board. L\Building Permits\BUP-RESPetnutApp.doc 01/25/2023 440-4613T(l l/02/COM/WEB) • Electrical Permit Application RECEIV IIIs FOR OFFICE USE ONLY City of Tigard OCT 16 ZI x' •,r, n 13125 SW Hall Blvd.,Tigard,OR 97223 stud Perms��•L�eltt l0�� 0 ' Phone: 503.718.2439 Fax: 503.598.1960111 Iggill_ Related Permit M: Inspection Line: 503.639.4175 CITY OF TIG ' i+ • El See Paget for I te,ARD. Internet: www.tigard-or.gov BUILDING DIV 91� na`eteod: lure: Supplemental Information TYPE OF WORK . ., PLAN REVIEW'�' El New construction ' a 0 Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/itcms checked): 0 Service or feeder 400 amps or more 0Building overthree stories. 0 Demolition l7 Other: Solar where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION ;" exceeds 10,000 amps at 150 volts or 0 Floating buildings. Q 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds I4,000 0 Commercial-use agricultural ❑Multi-famil amps for all other installations. buildings. y ❑Master builder ❑Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system larger separately derived Job#: Job site address: 12605 SW 128th Ave ❑Addition of new motor load of system. City/State/ZIP:Tigard, OR 97223 Six or or more. ❑ a cy. 1.3 ❑Six l more residential wilts. occupancy. $Uite/bld / k#: 0 Health-care facilities. ❑Recreational vehicle parks. g•aP Project name: Solar— Randy Lu ❑Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description I Qty. I Each l Total I * New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. Tax map/parcel#: 1,000 sq.ft.or less 168,54 4 DESCRIPTION OF WORK Ea.add•l 500 sq.ft.or portion 33.92 1 Limited energy,residential Installation of a roof-mounted 13.12kW PV System (with above sq.ft.) 75.00 2 Limited energy,multi-family residential(with above sq.ft.) 75.00 2 alitPROPERTY OWNER . Renewable Energy CI See Page 2 Services or feeders installation,alteration,and/or relocation Name:Randy Lu 200 amps or less 100.70 2 Address: 12605 SW 128th Ave 201 amps to 400 amps 133.56 2 City/State/ZIP:Tigard,OR 97223 401 amps to 600 amps 200.34 2 601 amps to 1,000 amps 301.04 2 Phone:(503 )840-4514 Fax:( ) Over 1,000 amps or volts 552.26 2 Email: randySlU@oOLCOm Temporary services or feeders installation,alteration,and/or relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 z i El APPLICANT El CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name:Sunpath Services above service or feeder fee, each branch circuit 7.42 2 Contact name:Maggie Ludden B.Fee for branch circuits without Address: 9978 SW Arctic Dr service or feeder fee,first 56.18 2 branch circuit City/State/ZIP:Beaverton,OR 97005 Each addl branch circuit 7.42 2 Phone:(907) 792-9290 Fax::( ) Miscellaneous(service or feeder not included) Each manufactured or modular l: dwelling,service and/or feeder Emai 67.84 2 maggie@sunpathservices.com Reconnect only 67.84 2 CONTRACTOR MI Pump or irrigation circle 67.84 2 Business name:Sunpath Services Sign or outline lighting 67.84 2 Address:9978 SW Arctic Dr Signal circuit(s)or limited-energy panel,alteration,or extension. 0 See Page 2 2 City/State/ZIP:Beaverton,OR 97005 Each additional inspection over allowable In any of the above Additional inspection(1 hr min) 66.25/hr Phone:(907) 792-9290 Fax:( ) Investigation(1 hr min) 90.00/hr Email:maggie@sunpathservices.com Industrial plant(Ihrmin) 78.18/hr Inspections for which no fee is CCB Lic.235715 Electrical Lic•CLR5O Suprv.Lic.: 122LRT s cifically listed(1/2hr min) 90.00/hr Suprv.Electrician signature,required: �Q- �n� T Subtotal: Print name:Maggie Ludden Date:10/16/23 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: Print name:Ma Ludde Thla permit application expires if a permit Is not obtained within 180 99le Date: 10/16/23 days aver it has been accepted as complete. • Number of inspections allowed per pemdt.C\Ituilding\Permica\EI.C_Pemorgpp_EI.R_ERE.doc Rev 06/17/2015 440A615T(11/05/COM/WEB • Electrical Permit Application-City of Tigard Page 2-Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Description ) Qty. I Each I Total I • Fee for all residential systems combined: $75.00 Renewable electrical energy systems: 5 kva or less 100.70 2 Check Type of Work Involved: 5.01 to is kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ >100 kva-no additional charge 0.0 3 Vacuum Systems* Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(Y2 hr min) ELECTRICAL PERMIT FEES COMMERCIAL WORK ONLY: Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 ' Number of inspections allowed per permit. (SEE OAR.918-309-0000) Check Type of Work Involved: n Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems n Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations InEluildineenoilslELC PermitApp_ELR_ERE.doc Rev 06/17/2015 City of Tigard RECEIVED .11111 Building Division OCT 1 6 2023 13125 SW Hall Blvd,Tigard,OR 97223 Phone: 503.718.2439 Fax:503.598.1960 BUILDING CITY DIVIS ON T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12605 SW 128th Ave City: Tigard Zip:97223 Owner's Name: Randy Lu Date: 10/16/23 Contractor's Name: Sunpath Services CCB #:235715 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ❑✓ No OSSC or ORSC for design requirements. Is the wind exposure Yes Wind Exposure "C"or less? If"Yes", qualifies for ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes IDYes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes",qualifies for above Yes the prescriptive path. n No I:Building/Forma/PhotoVo]laic-Checklist02-01-11.docx Is the construction O Yes Type of material wood and does If"Yes",qualifies for the construction qualify El No the prescriptive path. Construction as"conventional light frame"construction? Is the spacing 24 inches or less? Yes If"Yes",qualifies for Pre-engineered trusses. the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? If"Yes",qualifies for Nominal lumber. ❑ Yes the prescriptive path. ❑ No Is the combined weight Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation El Yes layout in accordance If"Yes",qualifies for with Section 305.4(3)of ❑ No the prescriptive path. the 2010 Oregon Solar Code? 0 Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofmg material shingle/shake checked, qualifies for Max. two layers the prescriptive path. 2 of composition shingle. Is the roof mounted Q Yes Connections of solar assembly If"Yes",qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? 2 1:Building/Forms/PhotoVoltaic-Checklist02-0I-11.docx ❑ Yes Is the gauge 26 or less? If"Yes",qualifies for 0 No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ® Yes the prescriptive path. ❑ No Attachment of roof mounted If the spacing falls solar systems Spacing of clamps? Minimum 24 inches y within 24 inches and 60 directly to inches inches, qualifies for the Maximum 60 inches standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes",qualifies for fastener? ri Yes the prescriptive path. II No Is the roof decking of WSP min. %2"thickness, 7 Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof J Yes the prescriptive path. surface. 0 No 3 I:/Building/Forms/photovoltaic-Checklst02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC SOLAR Model Number: REC410AA PURE (410W) MODULES Listing Agency: U L61730 4 I:Building/Forms/PhotoVoltalc-Checklist02-01-11.docx