Loading...
Permit (121) CITY OF TIGARD MASTER PERMIT • i COMMUNITY DEVELOPMENT Permit#: MST2023-00511 Date Issued: 11/06/2023 T f G A RD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S1060003300 Jurisdiction: Tigard Site address: 13765 SW 166TH AVE Subdivision: RIVER TERRACE TOWN CENTER Lot: Project: River Terrace Town Center, Lot 136 Project Description: New detached dwelling. NO FINAL INSPECTION UNTIL DEFERRED SDC FEES HAVE BEEN PAID. BUILDING Floor Areas Required Setbacks Required Stories: 2 Bedrooms: 4 First: 774 si Basement: 0 sf Left: 3 Parking Spaces: 0 Height: 26.5 Bathrooms: 3 Second: 1184 sf Garage: 502 sf Front: 12 Smoke Yes Right: 3 Detectors: Dwelling Units: 1 Third: 0 sf Ri 9 Total: 1958 sf Value: $364,839.54 Rear: 3 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckilw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y Ecompasing: Other: N Other Description: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF V8 R-3 1958 Owner: Contractor: TNHC OREGON LLC Required Items and Reports(Conditions) 15231 LAGUNA CANYON ROAD 1 Ersn Cntrl 503-639-4175 SUITE 250 2 1-HR FIRE RATED EAVES IRVINE,CA 92618 PHONE: PHONE: 503-312-6213 FAX: Total Fees: $23,246.29 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc,_nnl_nnrn fhr ,n ()AP oc,sn1_nnon rrw.e,j nhtnin a mnrw of tha mire nr rlirorr n„ocrnnc In(II IKIr'For raninnGFnn IJz7 101;7,,,,,,nrJJJ.1 Ann IT,Tzars Issued By: Ott Permittee Signature: / 1f 1r� Call 503.6 .4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential RECEIVED FOR OFFICE USE ON I.1 City of Tigard MillPermit No DateBReceived: h�' ( Z µ5t?.6L3'1�SIt • 13125 SW Hall Blvd.,Tigard OR Plan Review / S1A1F- J. it 0 9 2023 ��m �� Other Permit w Phone: W 1lal8.2439 Fax: OR 0 DateB : ! Ins ection Line: 503.639.4175 Date Ready/By: Hi See Page 4 for t'A R D p Notified/Method: 1 O ZIP 2 3 A + Supplemental Information Internet: www.tigard-or.gov CITY OF TIGARD BUILDING DIVISION .c. 1 .e.d 0--14.„.ta. TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING ❑Demolition Permit fees*are based on the value of the work performed. New construction Indicate the value(rounded to the nearest dollar)of all ❑ Additiori/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the I CATEGORY OF CONSTRUCTION work indicated on this application. i , e Q SC1 Valuation: $ , 40 aj1 ti7q r ❑� 1-and 2-family dwelling ❑Commercial/industrial Number of bedrooms: 4 ❑ Accessory building El Multi-familyfl Master builder ❑Other: Number of bathrooms: 5 JOB SITE INFORMATION AND LOCATION Total number of floors: 2 Zl(O Job site address:13765 SW 166th ave New dwelling area: 1958 square feet 11 194 City/State/ZIP:Sherwood/OR/97140 Garage/carport area: 502 square feet -11k4 Suite/bldg./apt.no.: Project name:River Terrace Town Center Covered porch area: 113 square feet Cross street/directions to job site: Deck area: square feet SW Jean Lntlice rr1 Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision:River Terrace Lot no.:136 Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.:parcel no: 2S 1060003300 equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Valuation: $ Requesting Deferred SDC fees Existing building area: square feet New building area: square feet ® PROPERTY OWNER 4„: ❑ TENANT Number of stories: Name:TNHC OREGON LLC Type of construction: Address:15231 Laguna Canyon RD STE 250 Occupancy groups: City/State/ZIP:Irvine/CA/92618 Existing: Phone:(503)310-7571 Fax:( ) New: © APPLICANT 0 CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:TNHC OREGON LLC Structural plan review fee(or deposit): Contact name:Frank Sandoval FLS plan review fee(if applicable): Address:15455 NW Greenbrier Parkway Suite 240 'total fees due upon application: City/State/ZIP:Beaverton/OR/97006 Amount received: Phone:(5031 310-7571 Fax: :( ) - _ PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail: fsandoval@nwhm.com Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name:TNHC OREGON LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:15231 Laguna Canyon RD STE 250 Solar Installation Specialty Code checklist. Cit /State/ZIP:Irvine/CA/92618 Permit Fee(includes plan review $180.00 Y and administrative fees): Phone:(503 )310-7571 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:241108 Total fee due upon application: $201.60 Authorized signature: ,/� This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Date:10/9/2023 *Fee methodology set by Tri-County Building Industry Print name:Frank Sandoval Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 01/25/2023 440-4613T(I 1/02/COM/WEB) Mechanical Permit Applic ��+EIVED Received FOR OFFICE USE ONLY City of Tigard �/ Date/By: Permit No.:rns-2023-0051 1 • 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review s. Phone: 503.7182439 Fax: 503.598.1•ti CT 0 9 Date/By: Other Permit: TIGARD Inspection Line, 503.639.4175 2023 Date Ready/By. Saris. Vi See Page 2 for Internet: www.tigard-or.gov CITY OF TIGARD Notified/Method: Supplemental Information BUILDING DIVISION TYPE OF WORK COMMERCIAL FEE* SCHEDULE — USE CHECKLIST Mechanical permit fees*are based on the value of the work ®New construction ❑Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition ❑Other: mechanical materials,equipment,labor,overhead,and profit. Value'$ CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT I SYSTEMS FEES* ® 1-and 2-family dwelling ❑Commercial/industrial D Accessory building For special information use checklist. ❑ Multi-family ❑ Master builder ❑Other: Description Qty. La_ Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 1 46.75 Job site address: 13765 SW 166th ave Furnace 100,000 BTU(duets/vents) 46.75 City/State/ZIP:Sherwood OR 97140 Furnace 100,000+BTU(doets/vents) 1 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name:River Terrace Town Center Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or SW Jean Louise rd hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision:River Terrace Town Center Lot no.: 136 Other fuel appliances: Tax map/parcel no.:2s1060003300 Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 1 33.39 Flue vent for water heater or gas NEW HOME CONSTRUCTION fireplace 23.32 Log lighter(gas) 23.32 _. -- Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 ® PROPERTY OWNER 0 TENANT Other: 23.32 Environmental exhaust and ventilation: Name:TNHC OREGON LLC Range hood/other kitchen equipment 1 33.39 Address:15231 Laguna Canyon Rd STE 250 Clothes dryer exhaust 33.39 City/State/ZIP:Irvine CA 92618 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(503)310-7571 Fax:( ) Attic/crawlspace fans 23.32 ® APPLICANT 0 CONTACT PERSON Other: 23.32 Business name' TNHC OREGON LLC Fuel piping: s14.15 for first four;$4.03 for each additional Contact name:Frank Sandoval Furnace,etc. Address:15455 NW Greenbrier Parkway#240 Gas heat pump Wall/suspended/unit heater City/State/ZIP:Beaverton OR 97006 Water heater Phone:(503)310-7571 Fax: :( ) Fireplace Range E-mail:f andoval@nwhm.corn Barbecue CONTRACTOR Clothes dryer(gas) Business name:Pro Heating and Cooling, INC Other: MECHANICAL PERMIT FEES* Address:4200 NW Leisy rd Subtotal City/State/ZIP:Hillsboro, OR 97124 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(971)205 4989 Fax:( ) State surcharge(12%of permit fee) CCB lie.:209001 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: C-421711-4444" * Fee methodology set by Tri-County Building Industry Service Board Print name:Elia Duran Date:3/17/2023 1.1BuildinglPermits1MFC_PermitApp_040113.doc 440-4617r(I I/02/COM/WEB) RECEIVED Electrical Permit Application FOR OFFICE USE ONLY OCT 09 2023 R eceived MS'19.U23 .OMlI • City of Tigard y Pem t : • • 13125 SW Hall Blvd.,Tigard,OR 97 Plan Review Related Permit H: Phone: 503.718.2439 Fax: 503.598�OF TIGARD Date/By: TIGARD, Inspection Line: 503.639.4175 BUILDING DIVISION Ready Date/By: furs: B See Paget for _ Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF WORK. PLAN REVIEW ®New construction 0 Addition/alteration/replacement Please check all that apply(submit F sets of plans w/items checked): 0 Service or feeder 400 amps or more 0 Building over three stories. El Demolition 0 Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. Ei I-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family 0 Master builder ❑Other: 0 Fire pump. 0 Installanon of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived .lob#: Job site address:13765 SW 166th ave 0 Addition of new motor load of system. 100HP or more. ❑"A""E" City/State/ZIP: Sherwood/ OR/97140 cis ix or more residential units. occupancy. ❑Health-care facilities. ❑Recreational vehicle parks. Suite/bldg.lapt#: Project name: RTTC ❑Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE SW Jean Louise rd Description I Qty I Each I Total New residential single-or multi-family dwelling unit. Subdivision: River Terrace Town Center Lot#:136 Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: 2s 1060003300 Fa add'I 500 sq.ft or portion 33.92 t DESCRIPTION OF WORK Limited energy,residential NEW HOME CONSTRUCTION (with above sq.ft.) 75.00 2 Limited energy.multi-family 75.00 2 residential(with above sq.ft) I� PROPERTY OWNER 0 TENANT Renewable Energy El See Page 2 Services or feeders installation,alteration,and/or relocation Name: THNC OREGON LLC 200 amps or less 100.70 2 Address: 15231 Laguna Canyon Rd STE 250 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Irvine CA 92618 601 amps to 1,000 amps 301 04 2 Phone:(503)310-7571 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: Fsandoval@newhomeco.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 RI APPLICANT ❑ CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name: THNC OREGON LLC above service or feeder fee, 7.42 2 each branch circuit Contact name: Frank Sandoval B.Fee for branch circuits withou! Address: 15455 NW Greenbrier Parkway#240 branch service fee,first 56.18 2 City/State/ZIP: Beaverton OR 97006 Each add'l branch circuit 742 2 Miscellaneous(service or feeder not included) Phone:(503)310-7571 Fax::( ) Each manufactured or modular dwelling,service and/or feeder 67.84 2 Email: Fsandoval@newhomeco.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:Development Northwest Inc., DBA Wolcott Electrical Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy 0 See Page 2 2 Address:1075 W Historic Columbia River Hwy panel,alteration,or extension. City/State/ZIP:Troutdale, OR, 97060 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(503)853-9420 Fax:( ) Investigation(1 hr min) 90.00/hr Industrial plant(1 hr min) 78.18/hr Email:MWOLCOTT@WOLCOTT.PRO Inspections for which no fee is CCB Lic.:112220 Electrical Lic.:C1272 Suprv.Lic.:5782S specifically listed(''/hr min) 90.00/hr ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: r Subtotal: nwa oa0.a.an�t.ron Print name:David Campbell Date:10/12/2023 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: 41.:4 ow TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Malachi J. Wolcott Date:10/12/2023 days after it has been accepted as complete. • Number of inspections allowed per permit I:/Dvildingrermits'J:LC PermitApp_ELR_ERE.doc Roe 06/17/2015 440-4615T(l l/05/COMfWEB Plumbing Permit ApplicatiRECEIVED Building Fixtures ffl1CCVV FOR OFFICE USE ONLY City of Tigard OCT 09 2023 Received �S1�Z3'�S Datel8 Permit No.: *I 13125 SW Hall Blvd.,Tigard,OR 97223 y` tt Phone: 503.718.2439 Fax: 503.598 Plan Review Other Permit No.' G`rl' OF TIGARD Date/Br Inspection Line: 503.639.4175 ----- ----- 1I C,A R I l Dote Ready/By: /arts. ® See Page 2 for Internet: wwev tigara-nrgov BUILDING DIVISION Notified/Method Supplemental Information TYPE OF WORK FEE* SCHEDULE ®New construction 0 Demolition For special information jive checklist Description I Qty. I Eu. I Total ❑Additiotdalleration/replacement ❑Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ® I-and 2-family dwelling Ill Commercial/industrial SFR(2)bath 1 437.78 ❑Accessory building ❑Multi-family SFR(3)bath 500.32 --- - Each additional bath/kitchen 25.02 ❑Master builder ❑Other: F ire sprinkler(_sq.ft.) Paget JOB SITE INFORMATION AND LOCATION Site utilities: Job site address: 13765 SW 166th Ave Catch basin or area drain 18.76 Drywell,leach line,or trench drain 18.76 City/State/ZIP: Sherwood/OR/97140 -----. Footing drain(no.linear ft.: ) Page 2 Suite/bldg./apt.no.: Project name: RTTC Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 SW Jean Louise Rd Rain drain connector 18.76 • Sanitary sewer(no linear ft:_) Page 2 Storm sewer(no.linear ft.: ) Page 2 Water service(no.linear ft.: ) Page 2 Subdivision: River Terrace Town Center Lot no.:136 Fixture or item: 'fax map/parcel no.: 2s 1060003300 Backflow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 • New Home Construction Clothes washer 25.02 - -- -- - Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 [Xi PROPERTY OWNER 0 TENANT Expansion tank 12.51 Name: TNHC OREGON LLC Fixture/sewer cap 25.02 Address: 15231 Laguna Canyon Rd STE 250 Floor drain/floor sink/hub 25.02 Garbage disposal 25.02 City/Slate/ZIP: Irvine CA 92618 Hose bib 25.02 Phone:(503)310-7571 Fax:( ) Ice maker 12.51 181 APPLICANT IN CONTACT PERSON Interceptor/grease trap 25.02 Business name: THNC OREGON LLC Medical gas(value:$_) Page Primer 12.51 Contact name: Frank Sandoval Roof drain(commercial) 12.51 Address: 15455 NW Greenbrier Parkway#240 Sink/basin/lavatory 25.02 City/State/ZIP: Beaverton OR 97006 _ Solar units(potable water) 62.54 Phone:(503)310-7571 Fax::( ) Tub/shower/shower pan 12.51 E-mail:u Urinal 25.02 CONTRACTORWater closet 25.02 Water heater 37.52 Business name:Walcott Plumbing Water piping/DWV 56.29 Address:1075 West Historic Columbia River Hwy Other: 25.02 City/State/ZIP:Troutdale OR. 97060 Subtotal Phone:( 503-667-1781 Fax:( ) Minimum permit fee: $72.50 CCB Lie.: Plan review (25%of permit fee) 112220�, n Plumbing Lic.no.:26824 PB ('` State surcharge(12%of permit fee) Authorized signature: TOTAL PERMIT FEE Print name:Mark Baleme Dale:10/12/2023 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. °Fee methodology set by Tri-County Building Industry Service Board. IiBmldingiPermiisIPI.MU.PermirApp.doc 10/01/09 440-46t6T(10l02/COM/WEa) 4-0 Atithit PRE SATEN EWES 1 ' Building Division 11 I One & Two-Family Dwelling rlcnKn Fees Checklist PERMIT INFORMATION: Application Date - FEE VERSION J (`J 20a' Permit #: rnC—��2 _0O 1 Plan #: i1 �5D � Floors: �l Valuation: J 3�4� 83°1.Sy Covered Porch: (/ 1 ) 2/ Basement Bedrooms: L J Deck: L�--J 1s`Floor 714 ` WC (toilets) Deck Cover: �, 2nd Floor \,\.�`t ( Lavatories Patio Cover 3`d Floor Tub/shower J 2 Accessory Struct. .-- R-3 Total t e1Jr't6 Laundry Tray am-- Water Heater ( / Gas Creel) Garage 502 Exhaust Vents 5- Gas Flue Vents Total for Elec. 2 v Backflow Prey. 1 (0D Heat Pump /CA( # for Electrical BBQ _____— Gas Fireplace ; #Fuel Lines FEES: Description: Fee App ' s: Fee Entered: DC Prov Revw: Planning Info Proc/Arch: Lg$2.00 (over 11x17) g L9 Info Proc/Arch: Sm $.50 (up to 11x17) -7 Sz Metro CET: Residential iJse 17 School CET: District: \` Tigard CET: Admin Tigard CET: ODHCS Tigard CET: AH Electrical Permit: Permit Fee: Limited Energy: 12% State Surcharge Mech. Permit: Permit Fee: 12% State Surcharge 1/ Plumbing Permit: Permit Fee: 12% State Surcharge Erosion Control: w/Permit- Ping I:\Building\Forms\ResPlanCheckFees_Dec2022_AA.doc 12/21/2.2 Page 1 City of Tigard COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Review - Residential T I G A R D ,n Building Permit #: MSt +1)-0611 Site Address: 13765 SW 166th Ave Verified in Accela Project Name: RT Town Center Lot/Unit #: 136 Proposal: New detached SFR Zone: C-C Housing Type: 0 SFR(0 Single Detached ❑ Duplex❑Triplex❑ADU) ❑ Rowhouse DCottage Cluster❑CYU ❑Quad❑Other Required Site Plan Elements: 0 3 copies of site plan on max 11x17" O Drawn to standard scale ❑ Rcta;,.zd L cca, J ip I / Li cc Nielection O North arrow 0 Street and site trees shown / labeled O Site address, project name, lot # turity O Street names (N/A for SFR) O Applicant name and phone # ❑ Courtyard rectangle dimcn3ioncd (if applicable) O Lot and setback dimensions "` ` " '' "'" ' "'"7' Vision clearance not required ❑ti�„"„y ,� ,��, �, ,,, , ti y 0 Utility locations &easements due to tract/private access. O Footprint of new structure and FFE 0 Property corner elevations O Sidewalk/driveway dimensioned — LIDA (-1,000 .,f O Lot area and lot coverage percentage 0 Erosion control Required Elevation Plan Elements: (For SFR: calcs needed only on street-facing) Summary table with calculations for: O Drawn to standard scale 0 Total facade area O Building height dimensioned 0 Total window and door area O Facade dimensioned O Windows and doors dimensioned 0 Garage doors dimensioned Re loor Plan Elements: (Not required for ❑ Summary table that includes ❑ Each story dimensioned ❑ Total floor area ❑ Each story floor area calculated ❑ o r story Planning Review The following standards have been met: Setbacks 0 Front: 8/12 Rear: 3 alley Side: 3 Min/Max Street Side: 7 / Garage: 3 alley Height 0 Max. Height: 35 Proposed Height: 26.5 0 Yes ❑ N/A Landscape ❑ Yes 0 N/A Screening (Quad only) 0 Yes ❑ N/A % Window Coverage 21% ❑ Yes 0 N/A Garage (SFR Only) Parking (Other Res)Alley load garage O Yes ❑ N/A Entrance (SFR, Rowhouse, Quad only) ❑ Yes 0 N/A Other building design standards (Rowhouse only) ❑ Yes 0 N/A Accessory Structure Standards ❑ Yes 0 No Qualifying pre-existing unit exempt from standards (Cottage unit only) r ditional standards for Courtyard Units, Cottage Clusters, Rowhouses, and Quads: ❑ Ye ty /A Unit Count: ❑ Yes ❑ N/. of Width and Size ❑ Yes ❑ N/A Pat''• _ Additional standards for -• rtyard Units and Cottage Clusters only: ❑ Yes ❑ N/A Unit Area: ❑ Yes ❑ N/A Floor Area (per story) ❑ Yes ❑ N/A Courtyard O Yes 0 N/A Fence ❑ Yes ❑ No mN/A Clean Water Services - Service Provider Letter (lot platted prior to 9/10/1995) ❑ Yes ❑ No 1N/A Public Facilities Improvement (PFI) Permit: Required: ❑ Yes ❑ No Applied For: ❑ Yes ❑ No, stop intake as Sensitive Lands: la Yes ❑ No O Main Land Use Case #s: PDR2021-00004 ❑ Conditions met o Applicant notified of land use expir a : Submit development plans by 1/31/25. Final occupancy by 1/31/27 Approved 6 Planning: — c Date: 9/14/23 t /11/ -3 Notes Only-34 permits can be Iss p for o recording of final pla Revision 1: ❑ Approved of Approved Date: Revision 2: ❑ Approved ❑ Not Approved Date: Building Permit Submittal Original Submittal Date: 10 j.,61l2-'2- Site Plans #: Building Plans #: Building Permit #: ,4uilding permit # entered on page 1 / Workflow Routing: 4Planning, 1 Engineering Permit Coordinator ICJ Building Workflow Sign-off: 4 Sign-off for Planning (include notes from planning review) Route Documents: I 'Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. I'Building: original permit application, site plans, building plans, engineer and beam calculations and trust details, if applicable, etc. I Z7 7 Permit Technician: �f--� - Date: to 110 � Notes: (I Engineering Review ❑ FI Permit: r le Slope at building pad: s fr/Al2(Conditions met prior to issuance of permit basements (encroachments) per engineering conditions of approval and plat Pi-Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes i2"No Assess Water Quantity Fee in-lieu: 0 Yes Fa"No LIDA Facility on lot: ❑ Yes "o Add Fee: ❑ Yes 0 No Final Plat Recorded 0 NOT Approved: Date: Notes: Approved By Engineering: Date: /o/zems Revision 1: 0 Approved No t Approved Date: Revision 2: 0 Approved ❑ Not Approved Date: Permit Coordinator Review Conditions met prior to permit issuance ❑ Approved, NOT Released: _ Date notified applicant: ❑ ENG Revisions Required: Date notified applicant: d\L] SDC Exemption: ❑ Applied for I: Received 1-#0oes not apply rDC Fees Entered: Wash Co Trans Dev Tax: ■ Yes 0 N/A Tigard Trans SDC: ■ Yes ❑ N/A t Deferred Parks SDC: Ili Yes CIN/A Deferred n LIDA a Yes n `. N/A �J'2 bK to Issue/Approved by Permit Coordinator: kk V Date: ��' �� vJ (/ Revision 1: CI Approved ❑ Not Approved Date: Revision 2: 0 Approved 0 Not Approved Date: