Permit (122) 71 CITY OF TIGARD MASTER PERMIT
COMMUNITY DEVELOPMENT Permit#: MST2023-00513
Date Issued: 11/06/2023
T t G A R P 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S1060003300
Jurisdiction: Tigard
Site address: 13743 SW 166TH AVE
Subdivision: RIVER TERRACE TOWN CENTER Lot:
Project: River Terrace Town Center, Lot 138
Project Description: New detached dwelling. NO FINAL INSPECTION UNTIL DEFERRED SDC FEES HAVE BEEN
PAID.
BUILDING
Floor Areas Required Setbacks Required
Stories: 2 Bedrooms: 4 First: 774 si Basement:
0 sf Left: 3 Parking Spaces: 0
Height: 26 Bathrooms: 3 Second: 1184 sf Garage: 448 sf Front: 12 Smoke Yes
Dwelling Units: 1
Third: 0 sf Right: 3 Detectors:
Total: 1958 sf Value: $361,316.10 Rear: 3
PLUMBING
Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays:
0 Rain Drain: 1 Urinals: 0
Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: Storm Sewer: 100
0
Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 0 Catch Basins: 0
Bckflw Prevntr:
Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0
Drywell-Trench Drain: 0 Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1
Natural Gas Heat Pump: N Hoods: 1 Other Units: 0
Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add,500 sf: 3 201-400 amp: 0 201-400 amp: 0 W/O SvclFdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y
Ecompasing:
Other: N Other Description:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
NEW SF VB R-3 1958
Owner: Contractor:
TNHC OREGON LLC Required Items and Reports(Conditions)
15231 LAGUNA CANYON ROAD 1 Ersn Cntrl 503-639-4175
SUITE 250 2 1-HR FIRE RATED EAVES
IRVINE,CA 92618
PHONE: PHONE: 503-312-6213
FAX:
Total Fees: $23,169.36
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
Q59-nnl-nnln rhrn,i r1AR oS2nm-nne av nhfaln a rem,of thu ndnc nr direct n„ocfinnc fn hi INC by Tallinn Sal 979 10A7 nr 1 Ann'119 99dd
,� e,t'Y I' I-r cej '-7
Issued By: Permittee Signature:
Call 3.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the lob site at the time of each inspection.
City of Tigard
71 ° COMMUNITY DEVELOPMENT DEPARTMENT
Building Permit Review - Residential
TIGARD
Building Permit #: ft& 2071?-OD'5
Site Address: 13743 SW 166th Avenue rd Verified in Accela
Project Name: River Terrace Town Center Lot/Unit #: 138
Proposal: New Single Detached SFR Zone: C-C
Housing Type: 21 SFR(Single Detached ❑ Duplex❑Triplex❑ADU)❑ Rowhouse ❑Cottage Cluster❑ CYU ❑Quad ❑Other
Required Site Plan Elements:
Se 3 copies of site plan on max 11x17"
Pf Drawn to standard scale 0 RctanicJ Licc>, Jiip-6rre/ licc jte tivn
i1 North arrow V Street and site trees shown / labeled
2f Site address, project name, lot # ❑ Tablc calculating trcc canopy at maturity
V Street names (N/A for SFR)
'Applicant name and phone # ❑ Courtyard rcctanglc dimcn3ioncd (if applicable)
l6'Lot and setback dimensions 61 Vision clearance triangle
❑ CAiatiriy 51.1uCturcS Q yuaic fvOtagk, gr Utility locations &easements
V Footprint of new structure and FFE 21 Property corner elevations
21 Sidewalk/driveway dimensioned ctLIDA (>1,000 sf disturbance)
6/Lot area and lot coverage percentage 6d'Erosion control
Required Elevation Plan Elements:
(For SFR: talcs needed only on street-facing) Summary table with calculations for:
61Drawn to standard scale VTotal facade area
Vf Building height dimensioned 21Total window and door area
a Façade dimensioned
V Windows and doors dimensioned
V Garage doors dimensioned
Requir Ian Elements:
(Not required for SFR ❑ Summary table that includes
❑ Each story dimensioned otal floor area
❑ Each story floor area calculated ❑ Floor ar
Planning Review
The followin standards have been met:
rch
Setbacks 'Max.t:1�buiI ng Rear: 3'alley Side: 3' Min/Max Street Side: 7' / Garage: 3' alley
Height C� Height: 35' Proposed Height: 25'-11 1/2"
0 Yes ❑ N/A Landscape
❑ Yes ¢I N/A Screening (Quad only)
V Yes ❑ N/A % Window Coverage
R(Yes ❑ N/A Garage (SFR Only) Parking (Other Res)
21Yes ❑ N/A Entrance (SFR, Rowhouse, Quad only)
❑ Yes N/A Other building design standards (Rowhouse only)
❑ Yes N/A Accessory Structure Standards
❑ Yes No Qualifying pre-existing unit exempt from standards (Cottage unit only)
Additional standards for Courtyard Units, Cottage Clusters, Rowhouses,and Quads:
❑ Yes N/A Unit Count:
❑ Yes N/A Lot Width and Size
❑ Yes N/A Pathway
Additional standards for Courtyard Units and Cottage Clusters only:
❑ Yes N/A Unit Area:
❑ Yes N/A Floor Area (per story)
❑ Yes N/A Courtyard
❑ Yes N/A Fence
❑ Yes 0 No i 'N/A Clean Water Services - Service Provider Letter (lot platted prior to 9/10/1995)
❑ Yes ❑ NoQfN/A Public Facilities Improvement (PFI) Permit:
Required: ❑ Yes ❑ No
Applied For: ❑ Yes ❑ No, stop intake
❑ Sensitive Lands: 'g Yes ❑ No
Main Land Use Case #s: PDR2021-00004 ❑ Conditions met
Applicant notified of land use expiratio e: Submit and a for all a licable dev ermits b 1/31/2025. Final occ b 1/31/2027
Approved By Planning: . _ .S Date: 9/14/2023 I C f4 /'a-3
Notes: Building permit can be issued prig o final plat but not prior to conditions being met
Revision 1: ❑ Approved ❑ Not Approved Date:
Revision 2: ❑ Approved ❑ Not Approved Date:
Building Permit Submittal
Original Submittal Date: l 0 °1 1-1/3Site Plans #: �£,
Building Plans #: '2)
Building Permit #: A Building permit # entered on page 1
Workflow Routing: V1 Planning A Engineering v'Permit Coordinator l Building
Workflow Sign-off: A.J Sign-off for Planning (include notes from planning review)
Route Documents: y Engineering: (1) copy of permit application, (1) site plan, (1) building plan
and original plan review routing form.
l Building: original permit application, site plans, building plans, engineer and
beam calculations and trust details, if applicable, etc.
PermitTechnician: Date: ID/3) /U
Notes:
Engineering Review
❑ PFI Permit:
A, Slope at building pad: ,4 %
fY eConditions met prior to issuance of permit
@3"Easements (encroachments) per engineering conditions of approval and plat
Water Quality/Quantity Facility:
Assess Water Quality Fee in-lieu: ❑ Yes f�No
Assess Water Quantity Fee in-lieu: ❑ Yes h-No
� � LIDA Facility on lot: ❑ Yes �No Add Fee: ❑ Yes ❑ No
Lg4inal Plat Recorded
❑ NOT Approved: Date:
Notes:
Approved By Engineering: Date: `d/1���3
Revision 1: ❑ Approved ❑ N Approved Date:
Revision 2: 0 Approved ❑ Not Approved Date:
Permit Coordinator Review
ie
onditions met prior to permit issuance
❑ Approved, NOT Released: Date notified applicant:
❑ ENG Revisions Required: Date notified applicant:
C Exemption:
OF
❑ Applied for ❑ Received _ Does not apply
DC Fees Entered: Wash Co Trans Dev Tax: -s N/A
Tigard Trans SDC: ii -s N/A l Deferred
Parks SDC: 0es N/A Deferred
/} LIDA ❑ Yes �jN/A
I9r4K to Issue/Approved by Permit Coordinator: ,{`v1, ' J`( - Date: ` 0' I?rZ
l/ Revision 1: 0 Approved ❑ Not Approved Date:
Revision 2: 0 Approved 0 Not Approved Date: