Loading...
Permit (130) RECEIVED OCT > > 20�3 City of Tigard cocITY 1F 1T 2023 II Building Division GARD BUILDING DIVISION 13125 SW Hall Blvd,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System - Property Information Installation Address: 16569 SW Darling Ln Zip: 97224 City: TIGARD 6l l012 Date: 3 Owner's Name: •KEVIN ANEMA CCB : 10 6 Contractor's Name: A and R Solar SPC,dba"A&R Solar" Design Parameters of the Property/Structure lf"Yes",does not qualify for the Is the installation ❑ Yes prescriptive path, follow Area plain/flood way? Flood Hazard Located in a flood © No OSSC or ORSC for desi_ requirements. ® Yes❑ If `Yes",qualifies for [s the wind exposure the prescr pt ve path. Wind Exposure "C"or less? No Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? If"Yes",qualifies for famm d ling/singleltw 0 Yes the prescriptive path. fily townhomes and/or their accessory No Ground structures. Snow Load is the Ground Snow Installations 50 psf or less? on all If„`Yes qualifies for structures other than Li Yes the prescriptive path. above El No I 1d13uilding'Fonn+PhatoVoltafc-Checklid02-01-1 I_docx • • • Is the construction t material wood and does Yes Construction the construction qualify as "conventional light ❑ No If"Yes", qualifies for the prescr pt ve path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ❑X Yes If"Yes", qualifies for the prescriptive path. Roof framing ❑ No members Is the spacing 24 inches or less? If"Y Nominal lumber. "Yes", Yesqualifies for the prescriptive path. ❑ No Is the combined weight of the PV modules and ® Yes racking less than or If"Yes", qualifies for Solar • equal to 4.5 psf? ❑ No the prescriptive path. installation Is the solar installation layout in accordance Yes with Section 305.4(3) of No❑ the 2010 Oregon Solar If"Yes", qualifies for the prescriptive path. Code? ❑ Metal Roofing Single layer Check the type of ❑ of wood If roofing material is material roofing material shingle/shake one of the three types checked, qualifies for Max. two layers the prescriptive path. ® of composition shingle. Is the roof mounted Connections o the solar assemblyEl Yes of solar assembly If"Yes" connected to roof to the roof framing or blocking ❑ No qualifies for the prescriptive path. directly? I::Binding,FormsPhetoVoltaic-Checklist02-01-I I.docx 2 ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the preset pt ve path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. • n No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for n Yes the prescriptive path. ❑ No Attachment of roof mounted If the spacing falls Minimum 24 inches solar systems Spacing of clamps? within 24 inches and 60 inches inches, qualifies for the directly.to Maximum 60 inches prescriptive path. standing seam metalpanels If the width of the panel Width of roofing is less than 18 inches, panels? 18 inches or less qualifies for the inches prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of ElIf"Yes", qualifies for fastener? Yes the prescriptive path. ❑ No Is the roof decking of WSP min. Y"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 L/BuildingiPonnsiPhotoVoltaic-Checklis102-01-I Ldocx 4 Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x I 1 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. • PV Modules Manufacturer: REC Solar Model Number: REC420AA Pure-R Listing Agency: UL 61730 • l:Building;Formsiphoto Voltaic-Checklist02-01-1 I.docx