Permit (152) IN .t CITY OF TIGARD MASTER PERMIT
: COMMUNITY DEVELOPMENT Permit#: MST2023-00608
T.i A R f 3 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 12/13l2023
Parcel: 2S112CD14700
Jurisdiction: Tigard
Site address: 7946 SW CAROL ANN CT
Subdivision: REBECCA MEADOWS Lot: 4
Project: Choedon
Project Description: Rooftop solar PV system 4.86 kW.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $6,577.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Bckflw Prevntr: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N
Other: Y Other Description: Rooftop solar array 4.86 kW Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VB R-3 0
Owner: Contractor:
CHOEDON,JANGCHUP TML INTERNATIONAL LLC Required Items and Reports(Conditions)
NAMGYAL,KARMA 6405 E MILL PLAIN BLVD
7946 SW CAROL ANN CT VANCOUVER,WA 98661
TIGARD,OR 97224
PHONE: PHONE: 800-364-0470
FAX:
Total Fees: $314.38
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law reqires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
0F911n1-M1n thrnirch n ox9-nn9-nn j7n,,,,,,nhtain a rnnv of*IA Tula nr rlirort nu<etinne to Al M y f:b Tallinn FA"{ 39 10R7 nr 1 Ann'4 2AAd
/AA ( ---
Issued By: / V /V I . Permitter)Signature: L
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Building Permit Application
Residential p EG IV FOR OFFICE USE ONLY
R G G `ti�A�,� 3 ��, '1M •as,08
City of Tigard DateBReceivedy: Permit No:MS1
• 13125 SW Hall Blvd.,Tigard,OR 97223 NOV 2 9 202 t Plan Review114 Date/By: � �i'^J'
ti Phone: 503.718.2439 Fax: 503.598.1960Other Permit:
�i
Inspection Line: 503.639.4175 Rr�ate Ready/By. - �/�� r ris I QI See Page 2 for
T t G A R L) g g CITY OF TIGA"mlotifiedlMedwd: 1114 �� �9 Supplemental Information
Internet: www.ti and-or. ov
BUILDING DIVISION ,YYIm/ MCPirt
TYPE OF WORK REQU[ DDATA:1-AND2-FAMILY DWELLING
❑New construction D Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
ElAddition/alteration/replacement ❑� Other:Solar equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSIRUCTION work indicated on this application.
Valuation: $6577.00
I] 1-and 2-family dwelling ElCommercial/industrial
❑Accessory building El Multi-familyNumber of bedrooms:
❑Master builder ❑Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address:7946 SW Carol Ann Ct New dwelling area: square feet
City/State/ZIP:Tigard OR 97224 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name:Solarinstall-JChoedon Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Lot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no.:W416729 Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Installation of 12 solar panels in 2 arrays on a roof-mounted 4.860kW PV System Valuation: $
Existing building area: square feet
New building area: square feet
Ir PROPERTY OWNER 0 TENANT Number of stories:
Name:Jangchup Choedon Type of construction:
Address:7946 SW Carol Ann Ct Occupancy groups:
City/State/ZIP:Tigard OR 97224 Existing:
Phone:( )971-335-7854 Fax: ( New:
APPLICANT I I CONTACT PERSON BUILDING PERMIT FEES*
(Please refer ra fee schedule
Business name:TML International LLC
Structural plan review fee(or deposit):
Contact name:Mary Dinsmore-Smith FLS plan review fee(if applicable):
Address:6405 E Mill Plain Blvd
Total fees due upon application:
City/State/ZIP:Vancouver, WA 98661
Phone:( )(360)326-0650 Fax: :( ) Amount received:
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
E-mail:permit@infinitysolarusa.com
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Business name:TML International LLC Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:6405 E Mill Plain Blvd Solar Installation Specialty Code checklist.
City/State/ZIP:Vancouver,WA 98661 Permit Fee(includes plan review $180.00
and administrative fees): _
Phone:( )(800)818-0598 Fax ( ) State surcharge(12%of permit fee): $21.60
CCB lie.:223690 Total fee due upon application: $201.60
Authorized signature: This permit application expires it a permit is not obtained
E�lIZQ,1'Y(.82.��'�{YL/�C/!� within 180 days after it has been accepted as complete.
Print name:Mary Dinsmore- Ith Date:1 1/2 812 02 3 *Fee methodology set by Tri-County Building Industry
Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
Electrical Permit Application RECEIVE'•
FOR OFFICE USE ONLY
V Received MS I1,o2 bbb68'
City of Tigard q q Receive Permtt N' s
• 13125 SW Hall Blvd.,Tigard,OR 97223 NOV 2 9 2023 Dan Review
Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit 4:
TIGARD Inspection Line: 503.639.4175 CAN OF TIGApRD` Ready Date/By: Saris Fa See Page 2 for
Internet: www.tigard-or.gov ,.otified/Method: Supplemental Information
TYPE OF WORK Bth.LD4{�G�jV'nl PLAN REVIEW
❑New construction 0 Addition/alteration/replacement Please cheek all that apply(submit 2 sets of plans w/items checked):
O Service or feeder 400 amps or more 0 Building over three stories.
❑ Demolition I Other:
where the available fault current 0 Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
❑• 1-and 2-family dwelling ❑Commercial/industrial ❑ Accessory building ess to ground,or exceeds 14,000 0 Commercial-use agricultural
amps for all other installations. buildings.
❑Multi-family ❑ Master builder ❑ Other: 0 Fire pump. 0 Installation of I50 KVA or
JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived
❑Addition of new motor load of system.
Job#: Job site address:7946 SW Carol Ann Ct I00l3P or more. ❑"A",'°B","t•z","l-3 ,
❑Six or more residential units. occupancy.
City/State/ZIP:Tigard OR 97224 ❑Health-care facilities. 0 Recreational vehicle parks.
Suite/bldg./apt.#: Project name:Solarinstall-JChoedon ❑Hazardous locations. 0 Supply voltage for more than
❑Service or feeder 600 amps or more. 600 volts nominal_
Cross street/directions to job site: FEE SCHEDULE
Description I Qtv. I Each I Total I "
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#:W416729 Ea.add'l 500 sq.ft.or portion 33,92 I
DESCRIPTION OF WORK Limited energy,residential
(with above sq.ft) 75,00 2
Installation of 12 panels in 2 arrays on a roof-mounted 4.860kW PV system Limited energy,multi-family •
75.00 2
residential(with above sq.ft.)
Renewable Energy IR See Page 2
El PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation
Name:Jangchup Choedon 200 amps or less 100.70 2
201 amps to 400 amps 133.56 2
Address:7946 SW Carol Ann Ct
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard OR 97224 601 amps to 1,000 amps 301.04 2
Phone:( )971-335-7854 Fax: ( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email:jan886155@gmail.com relocation
Owner installation: This installation is being made on property that I own which is not 200 amps or less 59.36 I
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
0 APPLICANT I ® CONTACT PERSON Branch circuits—new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name:TML International LLC above service or feeder fee, 7.42 2
each branch circuit
Contact name:Mary Dinsmore-Smith B.Fee for branch circuits without
service or feeder fee,first 56.18 2
Address:6405 E Mill Plain Blvd branch circuit
City/State/ZIP:Vancouver WA 98661 Each udd'l branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:( )360-326-0650 Fax: :( ) Each manufactured or modular 67.84 2
dwelling,service and/or feeder
Email:permit@infinitysolarusa.com Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name:TML International LLC Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy ID See Page 2 2
Address:6405 E Mill Plain Blvd panel,alteration,or extension.
Each additional inspection over allowable in any of the above
City/State/ZIP:Vancouver WA 98661 Additional inspection(I hr min) 66.25/hr
Phone:( )360-326-0650 Fax:( ) Investigation(I hr min) 90.00/hr
Email:permit@infinitysolarusa.com Industrial plant(1 hr min) 78.18/hr
Inspections for which no fee is 90.00/hr
CCB Lic.:223690 Electrical Lic.:C1556 Suprv. Lic.:4434S specifically listed(x hr min)
S ELECTRICAL PERMIT FEES
Suprv. Electrician signature,required: e7ZZAad_e. Subtotal:
Print name:Todd Rouse Date:11/28/2023 ❑Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee):
Authorized signature: D j41.454,12.- c5 TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within ISO
Print name:Mary Dinsmor mith Date:11/28/2023 days after it has been accepted as complete.
* Number of inspections allowed per permit.
I:\Building\Permits\ELC_Permii.App_ELR_ERE.doc Rev 06/17/2015 440-4615T(I1/05/CO[W'WEB
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Fee for all residential systems combined: S75.00 Description Qtr. I Each I Total I
3' Renewable electrical energy systems:
5 kva or less 1 100.70 100.70 2
Check Type of Work Involved:
5.01 to 15 kva 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2
with OAR 918-309-0040)
❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66 25/hr
charged at an hourly(1 lu min)
Inspections for which no fee is 90.00/hr
specifically listed(%hr min)
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES
Subtotal(Enter on Page I):
Fee for each commercial system: $75.00
y * Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
n Fire Alarm Installation
❑ HVAC
n Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
n Nurse Calls
n Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I\Building\PermitsiELC PermitApp_FIR_ERE due Rev Os/17/2015
• 1
II
City of Tigard
" Building Division
13125 SW Hall Blvd, Tigard, OR 97223
Phone: 503.718.2439 Fax: 503.598.1960
T I GA RD Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code RECEIVE)
)
Check List for Prescriptive Installation of Roof-Mounted NOV 2 9 202:
PhotoVoltaic Solar Panel System CITY OF TIGARD
BUILDING DIVISION
Property Information
Installation Address: 7946 SW Carol Ann Ct
City: Tigard Zip: 97224
Owner's Name:Jangchup Choedon Date: 11/28/2023
Contractor's Name:TML International LLC dba Infinity Solar USA CCB #: 223690
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? Q No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure I] Yes If"Yes", qualifies for
"C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes • Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
If"Yes", qualifies for
structures other than
El Yes the prescriptive path.
above
❑ No
1
1:/Building/Forms/PhotoVoltaic-Checklist02-01-1 I.docx
. * .
Is the construction
material wood and does ❑■ Yes
Type of If"Yes", qualifies for
Construction the construction qualify
as conventional light ❑ No the prescriptive path.
frame" construction?
Is the spacing 24 inches
or less?
If"Yes", qualifies for
Pre-engineered trusses. ❑■ Yes the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Is the combined weight ❑■ Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
ID
layout in accordance Yes
with Section 305.4(3) of If"Yes", qualifies for
IDthe 2010 Oregon Solar No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
n of composition
shingle.
Is the roof mounted
❑ Yes
Connections of solar assembly If"Yes", qualifies for
the solar assembly connected to roof ❑ No the prescriptive path.
to the roof framing or blocking
directly?
2
I:/Building/Forms/PhotoVoltaic-Checkl ist02-0I-11.docx
.
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
❑ If"Yes", qualifies for
Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less'?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
prescriptive path.
standing seam
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum #10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. Yz"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof ■❑ Yes the prescriptive path.
surface. ❑ No
3
I:/Building/Fonns/PhotoVoltaic-Checklist02-0I-I I.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer:ZNSH I N E
Model Number:ZXM7-S H 108-405M
Listing Agency: UL 61730
4
I:1Building/Forms/Photo Voltaic-Checklist02-0I-1 I_docx