Permit (72) CITY OF TIGARD MASTER PERMIT
« 4 �i COMMUNITY DEVELOPMENT Permit#: MST2023-00305
T WARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 11/13/2023
Parcel: 2S106DC21000
Jurisdiction: Tigard
Site address: 13912 SW 172ND AVE
Subdivision: RIVERSIDE AT SCHOLLS MEADOW Lot: 48
Project: Riverside at Scholls Meadow, Lot 48
Project Description: New detached dwelling.
BUILDING
Floor Areas Required Setbacks Required
Stories: 2 Bedrooms: 5 First: 1105 sf Basement: 0 sf Left: 3 Parking Spaces: 0
Height: 22 Bathrooms: 3 Second: 1469 sf Garage: 371 sf Front: 8 Smoke Yes
Dwelling Units: 1 Third: 0 sf Right: 3 Detectors:
Total: 2574 sf Value: $455,474.46 Rear: 10
PLUMBING
Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0
Lavatories: 5 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: Storm Sewer: 100
0
Tubs/Showers: 4 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1
Natural Gas Heat Pump: N Hoods: 1 Other Units: 0
Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 4
Fum>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits
1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add!500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Y
Other: N Other Description: Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
NEW SF VB R-3 2574
Owner: Contractor:
RIVERSIDE HOMES LLC RIVERSIDE HOMES LLC Required Items and Reports(Conditions)
15350 SW SEQUOIA PKWY STE 320 17933 NW EVERGREEN PKWY 370 1 Ersn Cntrl 503-639-4175
PORTLAND,OR 97224 BEAVERTON,OR 97006 2 (2)layers of 2x fire blocking
at area indicated
PHONE: PHONE: 503-645-0986
FAX: 503-690-2942
Total Fees: $51,121.39
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
oF9_M1-M1n thrni inn CAP oc ..nn1_rinon Vni i mmi in a rn Py of the rulee nr rlirort ni incline fn CH Mir by nmIlinn cm 949 10R7 nr 1 Rnn'i49 9144
Issued By: / Permittee Signature:
1503.639.4175 by 7:00 a.m.for the next available inspe on date. �yy, „S
This permit card shall be kept in a conspicuous place on the job site until completion of the proje . (��(�/
Approved plans are required on the job site at the time of each Inspection.
�2x — ,._,, b LL-
71
■ ' Building Division
One & Two-Family Dwelling
r 1 c n a n Fees Checklist
PERMIT INFORMATION: Application Date - FEE VERSION— Si(( 2-6 Z3
Permit#: )1A l Zo2.3— OP 3 OS—Plan #: Z5-7 Floors: 2--
Valuation: d 5 q 1'4 /..\ Covered Porch: -----____ Basement
Bedrooms: 5 Deck: 1"Floor j 1 p 5-
WC (toilets) 3 Deck Cover: 2nd Floor I l I
Lavatories 5 j Patio Cover — 3rd Floor
Tub/shower q Accessory Struct. ,__________ R-3 Total 25-1 y.
Laundry Tray Water Heater ( etca:d Elec Garage 3
Exhaust Vents S Gas Flue Vents - Total for Elec. 2 S
Backflow Prey. Ni_____."--- rn // Heat Pump�� # for Electrical y
BBQ _< Gas Fireplace `i- #Fuel Lines
FEES: Description: Fee Applies: Fee Entered:
DC Prov Revw: Planning v
Info Proc/Arch: Lg$2.00 (over 11x17) (7
Info Proc/Arch: Sm$.50 (up to 11x17) �(
Metro CET: Residential Use
School CET: District t'S ,..--'-
Tigard CET: Admin f
Tigard CET: ODHCS
Tigard CET: AH
Electrical Permit: Permit Fee:
Limited Energy: i.------
12%State Surcharge
Mech. Permit: Permit Fee:
12% State Surcharge
Plumbing Permit: Permit Fee:
12% State Surcharge
Erosion Control: w/Permit-Ping
----
Notes: () J ID` _ r-o-..Ls.��,br D r '-( L
— s -rs-12— el-(NR..._ SiLfou-e-v-h.er-,--,
am ,P 3b2. t
I:\Building\For ns esPlanCheckFees_Dec2022_AA.doc 12/21/22
Pagel
City of Tigard
ligCOe
MMUNITY DEVELOPMENT DEPARTMENT
Building Permit Review - Residential
TIGARD
Building Permit #: Vni,(I/1i '00'66)
Site Address: 13912 SW 172nd Ave M Verified in Accela
Project Name: Riverside at Scholls Meadow Lot/Unit #: 48
Proposal: New Single Detached SFR zone: RES C/RES E
Housing Type: X SFR(X Single Detached ❑ Duplex❑Triplex❑ADU)❑ Rowhouse❑Cottage Cluster❑ CYU ❑Quad ❑Other
Required Site Plan Elements:
X 3 copies of site plan on max 11x17"
X Drawn to standard scale ❑ R,,t..:,,,.d-t,eee, d,
X North arrow X Street and site trees shown / labeled
X Site address, project name, lot # ^ ' le realer latk4 trwa
N Street names (N/A for SFR)
1gl Applicant name and phone # ❑ C.,...tr.+.J ..U..,,yl.. JIIIR..,,,;,,,, J cf‘,F,r,r..dble)
NI Lot and setback dimensions a triangle
❑ E L v , .,,...1..,— & ..,,,,,., f...,l.,�.. X Utility locations & easements
X Footprint of new structure and FFE X Property corner elevations
X Sidewalk/driveway dimensioned ® LIDA (>1,000 sf disturbance)
X Lot area and lot coverage percentage ® Erosion control
Required Elevation Plan Elements:
(For SFR: calcs needed only on street-facing) Summary table with calculations for:
X Drawn to standard scale IE Total facade area
X Building height dimensioned E Total window and door area
E Facade dimensioned
E Windows and doors dimensioned
IM Garage doors dimensioned
Requir n Elements:
(Not required for SFR) ❑ Summary table that includes
❑ Each story dimensioned oor area
❑ Each story floor area calculated ❑ Floor area pe
Planning Review
The following standards have been met:
Setbacks M Front: 8' Rear: 10' Side: 3' Min/Max Street Side: 8' / Garage: 20'
Height ® Max. Height: 35' Proposed Height: 21' 3"
® Yes ❑ N/A Landscape 50% Proposed
❑ Yes IE N/A Screening (Quad only)
IX Yes ❑ N/A % Window Coverage 21% Proposed
E Yes ❑ N/A Garage (SFR Only) Parking (Other Res) Garage width <50% of street facing facade
M Yes ❑ N/A Entrance (SFR, Rowhouse, Quad only)
El Yes E N/A Other building design standards (Rowhouse only)
❑ Yes N/A Accessory Structure Standards
❑ Yes ® No Qualifying pre-existing unit exempt from standards (Cottage unit only)
•Add% ' al standards for Courtyard Units, Cottage Clusters, Rowhouses, and Quads:
❑ Yes ❑ N/A t:
❑ Yes ❑ N/A Lot Width and i
❑ Yes ❑ N/A Pathway
A'd ' Tonal standards for Courtyard Units and Cottage Clusters only:
❑ Yes ❑ Unit Area:
❑ Yes 0 N/A Floor er story)
❑ Yes ❑ N/A Courtyard
❑ Yes ❑ N/A Fence
❑ Yes ❑ No XN/A Clean Water Services - Service Provider Letter(lot platted prior to 9/10/1995)
NI Yes 0 No ON/A Public Facilities Improvement (PFI) Permit:
Required: IX Yes ❑ No
Applied For: X Yes ❑ No, stop intake
XSensitive Lands: ❑ Yes X No
® Main Land Use Case #s: PDR2021-00001 0 Conditions met
l:a Applicant notified of land use ex iration te: submit all ermits b 8/5/24 obtain c of o by 8/5/26
Approved By Planning: rt_-- ---- Date: 6/27/23 7f3/2-0 '3
Notes
Revision 1: 0 Approved Not Approved Date:
Revision 2: ❑ Approved ❑ Not Approved Date:
Building Permit Submittal
Original Submittal Date: 1 3
Site Plans #:
Building Plans #:
Building Permit #: I 'Building permit # entered on page 1
Workflow Routing: "Planning gtngineering 9"Permit Coordinator CAuilding
Workflow Sign-off: I "Sign-off for Planning (include notes from planning review)
Route Documents: 'Engineering: (1) copy of permit application, (1) site plan, (1) building plan
and original plan review routing form.
4uilding: original permit application, site plans, building plans, engineer and
beam calculations and trust details, if applicable, etc.Permit Technician: V WLGI/ Date: 1 I1 b,1 w 7/3
Notes:
Engineering Review
❑ PFI Permit:
Et/Slope at building pad: /A °A
M.-Conditions met prior to issuance of permit
g'Easements (encroachments) per engineering conditions of approval and plat
/0-Water Quality/Quantity Facility:
Assess Water Quality Fee in-lieu: ❑ Yes (Vo
Assess Water Quantity Fee in-lieu: 0 Yes 'No
LIDA Facility on lot: 0 Yes ®-No Add Fee: 0 Yes ❑ No
i4inal Plat Recorded
❑ NOT Approved: Date:
Notes:
Approved By Engineering: c Date: 7" /! 2 3
Revision 1: 0 Approved ❑ of Approved Date:
Revision 2: 0 Approved ❑ Not Approved Date:
PermitJ Coordinator Review
'Conditions Conditions met prior to permit issuance
Cl Approved, NOT Released: Date notified applicant:
O ENG Revisions Required: Date notified applicant:
*---
DC Exemption: 0 Applied for CI Received )C'PDoes not apply
t4DC Fees Entered: Wash Co Trans Dev Tax: ❑ Yes 0 N/A
T Tigard Trans SDC: ❑ Yes ❑ N/A 0 Deferred
Parks SDC: ❑ Yes ❑ N A ❑ Deferred
LIDA ❑ Yes /A
K to Issue/Approved by Permit Coordinator: a Date: -7. i - 3
Revision 1: ❑ Approved ❑ Not Approved Date:
Revision 2: 0 Approved 0 Not Approved Date: