Loading...
Permit (64) CITY OF TIGARD MASTER PERMIT I ' ' COMMUNITY DEVELOPMENT Permit#: MST2023-00246 T I t;ARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 06/21J2023 Parcel: 2S1126C09000 Jurisdiction: Tigard Site address: 14755 SW BOTH AVE . Subdivision: RAZE MEADOWS Lot: 13 Project: Ellermeier Project Description: Rooftop solar PV system 7.9 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $2,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywall-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof top solar array 7.9 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: ELLERMEIER FAMILY REVOCABLE TRUPRO STAT SERVICES LLC Required Items and Reports(Conditions) 14755 SW 80TH AVE 1721 NE 64TH AVE STE 120 TIGARD,OR 97224 VANCOUVER,WA 98661 PHONE: PHONE: (360)859-3749 FAX: Total Fees: $358.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law require. . o follow the rules adopted by the Oregon Utility Notification Center. Thosey/�rules are set forth in OAR 0c9_nn1 nn1n fhrn k? Y R%f1n n 1-n n nhf a rnnu of tha mlac nr rl ire t no aetinne In fll INr.by rollinn cn 99 1ga7 nr'I a 19 9 IdIssued By: Permittee Signature: 1503. y 7:00 a.m.for the next available inspection ate. This permit card shall be kept In a conspicuous place on the job site until completion of the project. Approved plans are required on the iob site at the time of each inspection. i Building Permit Application Residential RECEIVED FOR OFFICE USE ONLY City of Tigard RecE1Ved $ o ?I 13125 SW Hall Blvd.,Tigard,OR 97223 MAY 3 0 2023 Plan Review 3 P >� .0 —t9 6 Phone: 503.718.2439 Fax: 503.598.1 q� Date/By: 23 �� Other Permit: II c A P Inspection Line: 503.639.4175 Dam ReadyBy: n luris: RI See Page 2 for Internet: www.tigard-or.gov CITY OF TIGARD NotiSed/Methad: ��\.�� Su g BUILDING DIVISION VV ppteroentallnfurmation w-134.l d.LCf r, • TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING O New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ®Other:SOLAR equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ® 1-and 2-familydwelling ❑Commercial/industrial Valuation: S2,000 ElAccessory building 0 Multi-family Number of bedrooms: ❑Master builder 0 Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 14755 SW 80th Ave Tigard,OR 97224 New dwelling area: square feet City/State/ZIP:Tigard,OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.: Project name:ELLERMEIER,RICHARD Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK. work indicated on this application. SOLAR PV INSTALLATION Valuation: $ 7.9 kW Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: ELLERMEIER,RICHARD Type of construction: Address:14755 SW 80th Ave Tigard,OR 97224 Occupancy groups: City/State/ZIP:Tigard,OR 97224 Existing: Phone:(503)703-4675 Fax:( ) New: ® APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES* Business name:PROSTAT ELECTRIC (Please refer to fee scAedukJ Structural plan review fee(or deposit): Contact name:DALE KRUEGER FLS plan review fee(if applicable): Address:1721 NE 64TH AVE Total fees due upon application: City/State/ZIP:VANCOUVER,WA 98661 Amount received: Phone:(503)539-7772 Fax::( ) E-mail:dale.krueger@comcast net PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name:PROSTAT ELECTRIC Submit two(2)sets of roof plan with connection details Address:1721 NE 64TH AVE and fire department access,along with the 2010 Oregon Solar Installation Specialty Code checklist. City/State/ZIP:VANCOUVER,WA 98661 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(503)539-7772 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:189902 Total fee due upon application: $201.60 Authorized signature: Z7 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:DALE KRUEGER Date:5/5/23 *Fee methodology set by Tri-County Building Industry Service Board. I:1Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) . A Electrical Permit Application RECEIVE i I t)it c,I 1,1( 1 1 •F 11\1 \ City of Tigard Received iraee sy: T7 0�3 J c? `�io gl hone SW Hatt Blvd,Tigard OR 97223 MAY 3 0 2023 Plan Review Related Permit s: Phone: 503.718.2439 Fax: 503.598.1960 DattYBy: inspection line: 503.639.4175 CITY OF TIGARD Ro flea,«Iwa: Iwo �ppw Page a�asarmatiaa Internet: www.tigard-or.gov BUILDING fII IS10� , i r TYPE OF WORK i PLAN REVIEW U New construction ®Addition/alteration/replacement I Please check all that apply(submit 2 sets or plans wiitetts checked): 0 Service or feeder 460 amps or more 0 Building over three MACS- 0 Demolition 0 Other: where the available fault current ❑Minims and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 floating buildings. Q I-and 2-family dwelling 0 Commercial/industrial 0 Accessory building fess to ground,or exceeds 14,000 0 commercial-use agricultural amps for all other installations. buildings. ❑Multi-family 0 Master builder 0 Other: 0 Fire pomp. 0 Installation of l 50 KVA or JOB SITE INFORMATION AND LOCATION , ❑Emergency system larger separately derived ❑Addition of new motor load of system Job#: Job site address: 14755 SW 50th Ave Tigard,OR 97224 100HP or more. ❑`A "E, p-z", 1-3" Ci /SCatrJZIP: Tigard,OR 97224 ❑Six or more residential wets. occupancy. tY 9 ❑Health-dirt facilities. ❑Recreational vehicle parks. Suite/bld /a t. 0 Hazardous locations. ❑Supply voltage for more than g• P #: Project name: ELLERMEIER,RICHARD 0 Service or feeder 600 amps or more. 600 volt,nominal. Cross street/directions to job site: FEE SCHEDULE ikeedptioa I Qtr. 1 Farb i Twat I v New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'I 500 sq.R.or portion 33.92 1 DESCRIPTION OF We-vfORK - -- Limited energy,residential 75.00 2 r r ,j+�"�� (wish alcove sq. lti J�!'s�,rT� Limited energy,multi-family 75.00 2 7.9 kW residential(with above sq.ft.) PROPERTY OWNER ❑ TENANT Renewable Energy CI See Page 2 I ® Services or feeders installation,alteration,and/or relocation Name: ELLERMEIER,RICHARD 200 amps or less 100.70 2 Address: 14755 SW 80th Ave Tigard,OR 97224 201 amps to 400 amps 13356 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Tigard,OR 97224 601 amps to 1,000 amps 301.04 2 Phone:( 503-7)03-4675 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This ineratlation is being made on property that I own which is not 200 amps or less 5936 1 • intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 , pr AP�,LCANT J81 CONTACT PERSON ` Bench circuits—new,alteration,or eateasion,per pane ( L fP !��{ � A.Fee for branch circuits with Business name: t l 7 1 4 gw""� above service or feeder fee, 7.42 2 \'1�i( rack brunch circuit ' Contact name: .. >.• \Le5 e B.Fee for branch circuits wirhouf 1 ,� '�p service or feeder fee,fast 56.18 2 Address: (IAA �\.� J�t/e./�� branch circuit City/State/ZIP: t Vey �,��L,,. [/�A. Nn.L1 Fach add'1 branch circuit 7.42 2 f l Miseaseneons(stroke or feeder not included) Phone:(61} ) ei i 71 Fax::( ) Each manufactured or modular 6784 2 , {,,, dwrelling,service and/or feeder Email: �+ „11-4V.Ea®f ci r&c l.5 S • g-t€k Reconnect only 67.84 2 `fAL JCON"TRACTOR ' Pump or irrigation circle 67.84 2 i Business name: ifgi.i1 '� l[�� Sign or outline lighting 67.84 2 ��11��' r` panel. circuits)or limited-energy extension. ❑. ��e2 2 Address: 1 Va :! � paneE.alteration,or extension. City/State/ZIP: iU ( .i.-A--p c. a 'A?(0%,( Each additional inspection over allowable in any of the above 5-3 A a }� t� Additional inspection(i hr min) 66.25/hr Phone:(913) 5-3*d•+ 177 1r- Fax:( ) Investigation(1 hr min) 90.00/hr J It ,��,.a,(�, (�}•'� Industrial plant hrmin) 78.18/hr Email: v l dae' e Vw Cy `�p`" in„..s for which no fee is V specifically'listed(4:hr min} I 90.00/fir 1 CCB Lia: I( 4Z, Electrical -+. Suprv.Lic.: 1 72,4 S i AA ELECTRICAL PERMIT FEES Suprv.Electric': signature,retlu :ii4 � Subtotal: ❑Plan Review Required(25%ofpermit fee): name: �'. O 4i Date: 5/5/23aN State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: �+"�_ This permit application expires if a permit is not obtained within 186 Print name: Date: 5/5/23 days after it has been accepted as complete. • Number of inspections allowed per permit. b\luddingtl'ermtsdii.0 PamitApp Et.R_EB.E.doe Rev tffi'17/2015 44046)5T(11/05/COM/WEB w * Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE DFee for all residential systems combined: $75.00 Renewable I Qty. I Each l Total y R®ewable electrical energy systems: Check Type of Work Involved: s kva 1 7° _ z 5.01to15kva 133.56 2 0 Audio and Stereo Systems* o25 kva —zso34 2 Wind generation systems in excess of 25 kva: 0 Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 0 Garage Door Opener* 100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 0 Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva.over 25 7,42 3 ❑ Vacuum Systems* %100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: O Other: Each additional inspection is 66.25!hr charged at an hourly(1 be min) Inspections for which no fee is 90.00I hr specifically listed(%i hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00 Subtotal(Enter on Page I):Number of inspections allowed per permit (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* r] Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations \nuixdinstPermea\:LC_PeemkApp Eta_ERE.doc Rev06r'17401S RECEIVED City of Tigard MAY 3 0 2023 .li .g �� Building Division CITY OF TIGARD • 13125 SW Hall Blvd,Tigard,OR 97223 BUILDING DIVISION Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 14755 SW 80th Ave City: Tigard Zip: 97224 Owner's Name: Richard Ellermeier Date: 5/8/2023 Contractor's Name: Pro-Stat Services LLC CCB #: 189902 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ® Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? O No OSSC or ORSC for design requirements. • Yes Wind Exposure Is the wind expsure If"Yes", qualifies for "C" or less? ® No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes 0 Yes the prescriptive path. and/or their accessory Ground structures. ® No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than 0 Yes the prescriptive path. above 0 No 1 I:Building/Forms/PhotoVoltaic-Checklist02-01-I I.docx Is the construction Q Yes Type of material wood and does the construction qualify If"Yes",qualifies for Construction as"conventional light ® No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. ® No Roof framing members Is the spacing 24 inches or less? If"Yes",qualifies for Nominal lumber. ® Yes the prescriptive path. 0 No Is the combined weight • Yes of the PV modules and If"Yes", qualifies for racking less than or 0 No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation (� Yes layout in accordance ` If"Yes", qualifies for with Section 305.4(3) of ® No the prescriptive path. the 2010 Oregon Solar Code? 0 Metal Single layer If roofing material is Roofing ® of wood Check the type of one of the three types material roofing material shingle/shake checked,qualifies for Max. two layers the prescriptive path. 0 of composition shingle. Is the roof mounted Yes Connections of solar assembly 0 the solar assembly connected to roof 0 No If"Yes",qualifies for framingblockingthe prescriptive path. to the roof or directly? 2 I:Building/Forms/Photo Voltaic-ChecklistO2-01-11.docx Is the gauge 26 or less? ® Yes If"Yes",qualifies for 0 No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ® Yes the prescriptive path. 0 No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for 0 Yes the prescriptive path. 0 No Attachment of roof mounted If the spacing falls solar systems Spacing of clamps? Minimum 24 inches within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of Yes If"Yes", qualifies for fastener? the prescriptive path. 0 No Is the roof decking of WSP min. ''/2"thickness, 0 Yes decking connected to If"Yes", qualifies for framing members Q No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes",qualifies for solar modules module to the roof O Yes the prescriptive path. surface. 0 No 3 I:Building/Forms/Photo Voltaic-Checklist02-01-l 1.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: Mission Solar Model Number: MSE395SX9R Listing Agency: UL 1703 4 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx