Loading...
HomeMy WebLinkAboutPermit (68) CITY OF TIGARD MASTER PERMIT 3 COMMUNITY DEVELOPMENT Permit#: MST2023-00248 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 06/14/2023 T I C:A R D 9 Parcel: 2S112CB20400 Jurisdiction: Tigard Site address: 8190 SW NORFOLK LN Subdivision: HOGGANS PARK Lot: 10 Project: Lowe Project Description: Rooftop solar PV system 6.480kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $3,232.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywall-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener. N All Other: Y Other Description: Rooftop solar array 6.48 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: LOWE,COLLEEN A&BRIAN E TML INTERNATIONAL LLC Required Items and Reports(Conditions) 8190 SW NORFOLK LN 6405 E MILL PLAIN BLVD TIGARD,OR 97224 VANCOUVER,WA 98661 PHONE: PHONE: 800364-0470 FAX: Total Fees: $356.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR QS7_nn1_nnin fhrnunh y- 9_nn1_nnQn Vn,yC twin w rnna of the n,ra¢nr dirart al,c¢finn¢fn fir INr:Kw rarrinn Sni 7Z7 10R7 nr 1 Finn 117 7144 Issued By: / ��///tf Permittee Signature: �� // Call 503.639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each Inspection. Building Permit ApplicatiOU ECEIVED Residential FOR OFFICE USE ONLY City of Tigard MAY 3 0 2023 Received �d - 1 3 -✓ Date/By: �) PlitOi 1 Ta� —do�`['+3 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review � 3 Phone: 503.718.2439 Fax: 5o3.598.10Ty OF TIGARD Date,By: 5. Q Other Permit: TIGARD Inspection Line:g03.634175 BUILDING DIVISION Date Ready/By: /�3 �yt runs: ®PPe Page 2 for Internet: www.ti and-or. ov Notified/Method: </ Vl if) Supplemental Information TYPE OF WORK UIRED DATA:1-AND 2-FAMILY DWELLING ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ❑� Other:Solar equipment,materials,labor,overhead,and the profit for the O CATEGORY OF CONSTRUCTION work indicated on this application. 12 1-and 2-family dwelling ❑Commercial/industrial Valuation: S 3232.00 ❑Accessory building El Multi-familyNumber of bedrooms: El Master builder El Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address:8190 SW Norfolk Lane New dwelling area: square feet City/State/ZIP:Tigard OR 97224 Garage/carport area: square feet Suite/bldg/apt.no.: Project name:Solarinstall-CLowe Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Installation of 16 solar panels in 2 arrays on a roof-mounted 6.480kW PV System Valuation: S Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name:Colleen Lowe Type of construction: Address:8190 SW Norfolk Lane Occupancy groups: City/State/ZIP:Tigard OR 97224 Existing: Phone:( )503-869-7843 Fax:( ) New: ® APPLICANT NO CONTACT PERSON BUILDING PERMIT FEES* Business name:TML International LLC (Please refer N fee schedule) Structural plan review fee(or deposit): Contact name:Mary Dinsmore-Smith FLS plan review fee(if applicable): Address:6405 E Mill Plain Blvd Total fees due upon application: City/State/ZIP:Vancouver,WA 98661 Amount received: Phone:( )(360)326-0650 Fax: :( ) E-mail:permit@infinityd2d.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* CONTRACTOR Commercial and residential prescriptive installation of roof-top mounted PhotoVoltaic Solar Panel System. Business name:TML International LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:6405 E Mill Plain Blvd Solar Installation Specialty Code checklist. City/State/ZIP:Vancouver,WA 98661 Permit Fee(includes plan review $I80.00 and administrative fees): Phone:( )(800)818-0598 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lic.:2 V,240— -1 . ,3Io qb Total fee due upon application: $201.60 Authorized signature: This permit application expires if a permit is not obtained �e.{y,d{-yt tti.-' within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Print name:Mary Dinsmore- ith Date:5/25/2023 Service Board. I:\Building\Permits1BUP-RESPermitApp.doc 02/24/2011 440-4613T(I 1/02/COM/WEB) Electrical Permit Application FOR OFFICE USE ONLY City of Tigard Received Pe 7}`.,^f r e oa,�$ 13125 SW Hall Blvd.,Tigard,OR 97223 IN Date/B :Plan Review I. Phone: 503 718 2439 Fax: 503.598.1960 Date/B Related Permit 7. Inspection Line: 503.639.4175 Ready Date/By: tuns E1 See Page 2 for II GARD Internet: ov wwwti and-or. Notified/Method: g g Supplemental Information TYPE OF WORK PLAN REVIEW ❑New construction ®Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w Iran_.:necked). 0 Service or feeder 400 amps or more 0 Building over three stories. El Demolition ❑� Other:Solar where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. ❑� I-and 2-family dwelling ElCommerciaUindustrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family ['Master builder ❑Other: 0 Fire pump 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ['Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address:8190 SW Norfolk Lane tooHP or more ❑"A',`B", `1-2","1a", City/State/ZIP:Tigard OR 97224 0 Six or more residential units. occupancy. 0 Recreational vehicle parks. 0 Health-care facilities. 0 Hazardous locations. El Supply voltage for more than Suite/bldg./apt.#: Project name:Solarinstall-CLowe 0 Service or feeder 600 amps ur more 600 volts nominal Cross street/directions to job site: FEE SCHEDULE Description I Oh'. I Each I 'Fatal 1 " New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea,add'l 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential Installation of 16 solar panels in 2 arrays on a roof-mounted 6.480kW PV System (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy ee Page 2 II PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation Name:Colleen Lowe 200 amps or less 100.70 2 Address:8190 SW Norfolk Lane 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard OR 97224 601 amps to 1,000 amps 301.04 2 Phone:( )503-869-7843 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:lowe.colleen3@gmail.com relocation Owner installation: This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature:Authorized VIA Contract Date: 401 amps to 599 amps 168.54 2 ® APPLICANT ® CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name:TML International LLC above service or feeder fee, each branch circuit 7.42 2 Contact name:Mary Dinsmore-Smith B.Fee for branch circuits withoal service or feeder fee,first Address:6405 E Mill Plain Blvd branch circuit 56.18 2 City/State/ZIP:Vancouver, WA 98661 Each add')branch circuit 7.42 2 • Miscellaneous(service or feeder not included) Phone: ( )(360)326-0650 Fax: :( ) Each manufactured or modular 67,84 2 dwelling,service and/or feeder Email:permit@infinityd2d.com Reconnect only 67.84 2 • CONTRACTOR Pump or irrigation circle 67.84 2 I Business name:TML International LLC Sign or outline lighting 67.84 2 Address:6405 E Mill Plain Blvd Signal lterat(s)orlimited-energy alteration,alteration,or extension. 0 See Paget 2 Each additional inspection over allowable in any of the above City/State/ZIP:Vancouver,WA 98661 Additional inspection(I hr min) 66.25/hr Phone:( )(800)818-0598 Fax:( ) Investigation(1 hr min) 90.00/hr Industrial plant(I hr min) 78.18/hr Email:permit@infinityd2d.com Inspections for which no fee is CCB Lie.:223690 Electrical Lic.:C1556 Suprv.Lie.:6210S specifically listed('Ahr min) 90.00/hr ELECTRICAL PERMIT FEES Suprv.Electrician signature,required:rco'z ,LRZ)ue Subtotal: Print name:Scott LeDuc Date:5/25/2023 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): • Authorized signature: W �!Y4Q{YLB2 Q cal TOTAL PERMIT FEE. A S This permit application expires if a permit is not obtained within 180 Print name:Mary Dinsmor mith Date:5/25/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. 1.\B0i1ding\Permits\ELC_PermtApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(I I/05/COMIWEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Description I Qty. I Each I Total I " Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: El Other: Each additional inspection is 66.25/hr charged al an hourly(1 hr nun) Inspections for which no fcc is 90 00/hr specifically listed(14 hr min) ELECTRICAL PERMIT FEES COMMERCIAL WORK ONLY: Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: El Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC El Instrumentation El Intercom and Paging Systems El Landscape Irrigation Control* El Medical El Nurse Calls El Outdoor Landscape Lighting* ❑ Protective Signaling El Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations t\Buildmg\Pennits\ELC_PerntilApp ELR ERE.doe Rev 06172015 RECEIVED MAY 3 0 2023 City of Tigard CITY OF TIGARD lo Building Division BUILDING DIVISION c 13125 SW Hall Blvd,Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 T I GA R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 8190 SW Norfolk Lane City: Tigard Zip: 97224 Owner's Name:Colleen Lowe Date: 5/25/2023 Contractor's Name:TML International LLC dba Infinity Solar CCB #: 223690 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation � Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? No OSSC or ORSC for design requirements. is the wind exposure 0 Yes If"Yes", qualifies for Wind Exposure "C"or less? 0 No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes 0 Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? ❑ If"Yes", qualifies for structures other than Yes the prescriptive path. above ❑ No 1 I/Building/Forms/Photovoltaic-Checklist02-01-1l.docx Is the construction material wood and does 0 Yes Type of If"Yes", qualifies for the construction qualify ❑ No the prescriptive path. Construction as "conventional light frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ❑� Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Is the combined weight ❑■ Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ❑■ Yes If"Yes", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. of composition shingle. Is the roof mounted ❑■ Yes Connections of solar assembly the solar assembly connected to roof No If"Yes",prescriptiveqpaeies for framingor blockin ❑ the path. to the roof g directly? 2 I/Building/Forms/PhotoVoltaic-Checklist02-0I-I I.docx Is the gauge 26 or less? ❑ Yes If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for D Yes the prescriptive path. 0 No Attachment of roof mounted If the spacing falls Spacing of clamps? Minimum 24 inches within 24 inches and 60 solar systems P g cam P directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? 0 Yes the prescriptive path. ❑ No Is the roof decking of WSP min. '/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ■❑ Yes the prescriptive path. surface. 0 No 3 I/Building/Forms/PhotoVoltaic-ChecklistO2-Ol-I I.docx II Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer:ZNS H I NE Model Number:ZXM7-SH 108-405M Listing Agency: UL 61730 4 I1Building/Fortes/PhotoVoltaic-Checklist02-01-1 I.docx