Plans (65) Installation complies with RS402 and VALIDITY OF PERMIT IFC .1.2 3'pathways throughout THE ISSUANCE OF A PERMIT Compp roof roof 26 deg slope two story Attachments every 4'oC 2'within 3'of roof edge BASED ON CONSTRUCTION System parallel with roof surface DOCUMENTS AND OTHER ww'' no part of the modules to go over the roof line DATA SHALL NOT PREVENT 1IL..... 12"from every ridge per Section 3111.4.6.1 THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. ORSC 105.4 Southwest Botany Bay Lane CITY OF TIGARD REVIEWED FO CODE COMPLIANCE Approved: [✓] Approved plans shall be on job site. OTC: 1 1 Perniit #: (GC V 7- -- CYO ZVy Driveway Address: ,t¢12�j� SW ga� J en �c.�p — Rapid shutdown/AC Suite #: I ` disco on exterior wall of By: W Date: /(U.(t1. home next to utility meter Electrical Panel OFFICE COPY , 3' Fire Pathway LIABILITY .p' The City of Tigard and its °•>i Qt employees shall not be 3' Fire Pathway responsible fo: c-°e�puncies � &— a which may type:ir herein. Suneye•" °°,)7 Sky 02 7i9 •7 Solar array on roof ^ 3' Fire Pathway Modules 40"x72"� ,,CP N.. \ micro inverters under ,N modules 9e 1 e 0 1 *Suneye Sky 01 01 Site Plan Moola Job: Moola 16630 Southwest Botany Bay Lane Tigard, OR 97224 Voltage Drop Calculation Longest run V Drop for Branch = 0.32 V.Drop Array to disco 40'10awg= 1.032% V. Drop Array to panel 2'8awg =0.036% Total AC Voltage Drop = 1.388% vamp=(ampaMnverter'W ormvernarn)*(reeleenee O,em 2 way wire length)LONGEST BRANCH RUN Modules and inverters grounded per 690.43 with listed rail clips PV pv PV pv Meter on side of Utility meter Module Module Module Module building 0 0 less than 5'from AC 0 0 / disconnect and OCPD Lei _ GM -\.- 5-W-- a Combiner box with 60A Disconnect Leviton '�C branch OCPDs Rapid shutdown 4 Modules with Inverter Black 1 lockable blade type O®G 2 CP720 Red-L2 I Next to meter White-N / / Green-G di /� H 21 A 16 Modules wit I 8 CP720 r e _......,4, © - - Z a cm -i _._. / 1-40A PV PV pv pv Conductors=#10AWG Conductors=#8AWG Module Module Module Module Neutral=#10AWG Neutral=#8AWG comms only Ground #10AWG Ground #8AWG Longest Distance 40' Distance 2' PV Module Ratings Inverter Specs: Manufacture: REC Manufacture:Chilicon Model#: REC410AAPure Module:CP720,CP250 Open-CircuitMax Output Current:3A, 1.2A Voltage:48.9V Nominal Output Volts: 240V Operation Voltage: 42.4V Output Frequency: 59.3hz-60.5hZ Max String Voltage: 1000V Output Volt Range:211V-264V 02 Electrical Diagram Moola Operating Current: 10.65A AC Point of Interconnection — Total number of Modules:20 NEC 690.54): Job: Moola Short-Circuit Current: 10.30A S stem Size:8.2kW Max Series Fuse: 25A y Rated AC output:30A 16630 Southwest Botany Bay Lane Estimated Annual Production: (#of invertersX3A) Tigard, OR 97224 Maximum Power(STC):390.8W 9,400 kWh9 VOCTempCoeff: -.24%C Nominal AC Voltage:240V Ntir_i 1 sorer SPANS2x4 Hem Fir Engineered truss 24" OC 5' max span 5' 5' 5' *Spans comply with Table 802.5.1 (3) Lumber = Hem Fir #2 Comp roof, one layer ELEVATION ` 18" Section • 3111 .5.3.5 IS 26° 8' 03_Truss Plan Moola Job: Moola 16630 Southwest Botany Bay Lane Tigard, OR 97224 REC ALPHA PURE SERIES _�� IEC PRODUCT SPECIFICATIONS SOLAR'S MOST TRUSTED al.c tazt xzs Pt zro ll 29[t.❑ 901 f3351 - 460118 lg h erajunc nbfacialcellswitb Ceti • type- lead-free, aplesatechnolog Estrin af22 cells inseries 4 - -� �7 1337 I6 , .; Glass: 0.13in(3.2mm)solarglasswithanti-reflechvesurfacetreatment IJ 1100193.31+ in accordance with EN 12150il3 : Backsheet: Highly resistant potymer(blatk) i 6.0x0.7 Frame: Anodized aluminum(black) -� [o�aso.o0 y; o 3-part,3 bypass diodes.lead-free T1 g Junction box: �; € Ifigirated,m arc ordance with lEC 62748 y Staubli MC4 PV-KBT4/KST4(4 mm2) 'gl nio.z Connectors: if,in accordance with lEC 62852,IP68 only when connected i voloa3xo.o11 12AWG(4mm'1PVwire.43+47irt(11+1.2m) p Cable: 12oowul - inaccocdercewithENS0618 1 205s05 1.�t- I 10.8x002] N . Dimensions: 71.7x40x1.2 in(19.910)/1821 x1016 x30 mm(185 m2) j - e 153.716.051 Weight: 45lhs(20.5kg) .f - __ Y_._ -r + 451t.e1 123091 6T t3126A 30.127 ; Origin. Made in Singapore f r---^----^- . _ '3011.21 1 r1ais r,menu In mm 1,M ELECTRICAL DATA r,t ' Product.Code*:RECxx xA A Pure ,3 ;a; -°,., iipr,'. Power Output-P,,�,tx(Wp) 380 385 390 395 400 405 410 IEC612152016.1EC6173D2016. L61730 Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 0/+5 0/+5 0/ 1EC62804 PID +5 .. _. 'IEC61701 Sad Mist Nominal Power Volt Voltage 40:9 412 41.5 41.8 42.1 42.4 42.7 ag N�(V) IEC 6271E Ammonia Resistance Li Nominal Power Current-I,,,m(A) 9.30 9.35 9.40 945 9.51 9.56 9.61 I.UL61730 Fire Type Class 2 N Open Circuit Voltage-Voc(V). 484 485 48.6 48.7 48.8 48.9 49.0 IEC62782 Dynamic Mechanical Load IEC61215.22016 Hailstone(35mm) Short Circuit Current-I,(A) 10.17 10.18 10.22 10.25 10.28 10.30 10.35 IECE2321 Lead-free acc.toRoH5EU863/2015 Power Density(W/ft?) 191 19.3 19.6 19.8 20.1 20.3 20.6 15014001,15090011EC4500;1EC62941 Panel Efficiency(%) 20.5 208 21.1 21.4 21.6 21.9 22.2 & •n ♦ E /y„ Power Output-Pu4x(Wp)' 290 293 297 301 305 309 312 w�rar ` �%rfpe Nominal Power Voltage-V„e,(V) 38.5 38-8 39.1 39.4 39.7 40.0 40-2 f-, NomtnalPoyner{accent-Ix (A) 751 755 7.59 7.b3 768 ; 772 7,7E Nominal Module Operating Temperature: 44'C(42°C) Z e-V Volta Circuit Open V 45.6 45.7 45.8 45.9 46.0 46.1 462 P g oc O Temperature coefficient ofp,,.x: -0.26°//°C Short Circuit Current-i0(A) 812 816 820 8.24 8.28 8.32 8.36 Temperature coefficient ofVa: -0.24%/°C Valuesat standardtestcanditians(STC:air mass AMIS.irradiance 1075W/sq R0000W/m'),temperature77°F(25Y),based onaproductian spread Temperature coefficient ofl : 0.04%/°C withatoleranceufP ,Va&tcx3%withn one watt class.Nommal module operatingtemperature(NMOT:air mass AMl.S,irradience800 W/m', p sr temperature 68°F(20°Ctwirxlspeed33ft/s(int/s).'Where x+a indicates the nominal power class(P,,,,)at STC above 'The temperature coefficients stated are linear values ..r ' _ ;e �.' '`+ "DELIVERY INFORMATION � %. e.'`t Operational temperature: -40,..+BS°C Standard RECProTrust Panels per pallet 33 Maximum system voltage: 1000 V Installed by an REC No Yes Yes Panels per 40 ft GP/high cube container. 792(24 pallets) Lt Certified Solar Professional E Maximum test Load(front): +7000Pa(1461bs/ft')' Panels per 53 ft truck, 891(27pallets) System size All 425 kW 25-500 kW 3 Maximum test load(rear): -4000 Pa(83,51bs/ft2)- Product Warranty(yrs) 20 25 %5 LOW i LIGHT BEHAVIOUR ; l;.. Max series fuse rating: 25A Power Warranty(yrs) 25 25. 25 go Typical low irradiance performance of module at STC: Max reverse current: 25A Labor Warranty(yrs) 0 25 10 'See installation manual for mounting instructions -Power in Year 98% 98% 98%. Design load-Test load/1.5(safety factor) 1Fi Annual Degradation 0.25% 025% 0.25% .. .. Power in Year 25 92% 924E 929E o See warranty documents for details.Conditions apply ¢ . n m v. Irradiance(Wire) CI C n m N N R O 1, Cc 13 13 ,' 1 N 1'.� Founded in1996.REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean,affordable solar power.As •E, 4 c Solar's Mast Trusted.REC is committed to high quality,innovation,and a low carbon footprint in the solar materials and solar panels it manufactures. 1 - n i Headquartered in Norway with operational headquarters ie Singapore,REC also has regional hubs in North America,Europe,and Asia-Pacific. www.recgroup.com a a. 0 snekk- SOLAR'S MOST TRUSTED • R E C ,..„.....:-.„.......,,-- , .,„.„.„...„.......... . ke.4911.4s18::io!,4,..F..„H„,,,..-:,.....,..,:-...:,,,..:..:.......,...,..... .„... :,"1:ifin.u..tzliriii.]:,:;.:,.i..,,:co,!:;,!.:..:,.]:,7,:!.::...2•!i::,-',,,„--,-.•-,:-,,, - • solar i ...,.. -....w„,„:„.,...„.,.. .. . . -„, ....„...,.... .... , .. , . • •• . • ••••: ..:.. : • ••., .. award .. • . •......,'.. • ,. , • ....:..:„.,,.,,,....,.,.,,.,...,...... . .••••„:„,„:„,„.„,....„„.„. . ,, .... ....•,....,,...)0-- I 1hp, :„„,,,,„,,,.. ,, , ,,.„•.:...•,,-,.,,•.„,„",7-,.!•,,••„:,,,,,,.•,,,•..„.•.,,.!.•,•,-,•:•..1:,:,:,:',„"1,r,..-.',..8.„,g.,..,,.•l4•a.,„.,.„.3r.4,,i4..„,:'.t4 0.:.,....,i:g,.•F„,..A4.:,.n -..•:...*..,.„:i,-,„i„::•E"•",:.-' 4- :-',.''...:....0.-- 2022 FINALIST cr .J.,....e.:::-.,,,-,,,,,.:er. ..... ........,,„...:„.„,,.,.. . . .,....., • .. : .„.....,....... .. ... .. ..„......., • , . •• ..,•, •.,,,,,,:,,:,,,,:„,.:,:.,•.:::::,. ,, •, ,•,•:...r.,::;„•,:.•::,:::::::,,,,:i,.:,••. . . -.::„...„....::„.,..„:„..,,, ; 0i.:::-..-.. : ::..,......,:.f,...:...... .44-4h!...,..,„. :ii#:!•?:,;,.1::::,.,:t:! :,-.,:..-..--,:i.,:!.:.•••..r:-.--•i.i::::i,::.....• '!".14-,,,g::,1:i.:-: ::E!,:o,'-': ......................„.......„,.„...„.„:„..... ,,..:.,.::..:.:.'.::::::::..:......:::-:,::.-.00::::,:t:::mf.1,!m:::,1•!!,,m,.."'"'"'"''''''':-------.:-:—- -- ,.:.:.:::::::::::::-'...-: •: :::i-::.::.--.:- ---:-:: -- :::::-:-----•::::: - ... .. :...,::........:: •: .... . _. . .....,.,.. •._ .. . :.„::::::.:::: :: - : • ,• ......,,,.....„.„:„..::.,,,,,,::.:: : ...:. „: ,..:: ,5:,,,,,,,,.., .. .....„ ; „.... . ..•.,...-..:_.-.....:,.....;..,...-„-:,..:.,--.,:.7::..:;•:.:::-,..k... .:-. :.--::„,----..-- -• - i.fe vin; COMPACT"•!''''''.•-••••'-'''' -• ....-„:„...:, ......:::,..„.,,,.. ... ......:-...::•-...-:-- PANEL SIZE EXPERIENCE REC 410 WP 25 YEAR PROTRUST. :.Ro zkiv Ty EE 19.3 "-FT2 T M 22.2 ELIGIBLE LEAD-FREE c/o EFFICIENCY PERFORMANCE REV720 11.24.20 Chilicon Power Microinverters CHILICON POWER CP-720 Dual Panel Microinverter - suenim,roul --ems Ily • -0a, � �� 1 CP-720TM Series Microinverters Performance •Supports up to 840W with no clipping(or 2x420W) The Chilicon CP-720 allows installers to • Maximizes energy production over life of system maximize PV system production, while • Minimizes losses due to shading and debris minimizing installation and operational • Eliminates single point of failure for system costs. Microinverter based architectures offer the benefit of increased flexibility in Simplicity module deployment, while also providing •All AC design—No string calculations needed • No GEC needed for microinverters per module visibility to simplify system • Easy installation with standardized trunk cables O&M. With its all-AC approach, integrated grounding, modular bus cabling, and ability Versatility to support up to 20 modules on a 30A • Compatible with most 60, 72, 96 & 128 cell panels branch circuit, the CP-720 simplifies both •Single SKU 240V or 208V design and installation. Both freq-Watt and •Allows for variable module placement volt-Watt modes allow AC control in off-grid • Robust PLC communication protocol (>500 ft range) battery or generator systems. Coupled with •Self supply mode (zero export) the CP 100 gateway and cloud based •Supports up to 30A branch circuits • Up to 20 panels possible on one branch circuit monitoring software, the CP-720 can form the energy management backbone of both Reliability, Safety, & Compliance residential and commercial PV systems. • NEMA 6 rated construction • 25 year warranty •AC branch circuits will not support arc faults •Quick disconnect circuit to mitigate grid instabilities _+ � c us • NEC 690.12(B)(2) rapid shutdown compliant MADE IN USA s a Intertek • CA Rule 21 (UL 1741-SA) compliant : ;; Chilicon www.chiliconpower.com • trojorwmai CP-720-60/72/96-208/240-MC4 Microinverter Specifications INPUT DATA(DC) Recommended input power(STC) (190-450 W)x 2;(380-900 W)x 1 Maximum DC input voltage 120 V MPPT voltage tracking range 56-82 V Operating range 48-102 V1 Min./Max.start voltage 55-102 VI- Max.DC input short circuit current 16 A Max.DC input current 13.5 A Ground fault protection Transformer isolated 2000 Vrms input/output/chassis OUTPUT DATA(AC) @ 208 V @ 240 V Max.continuous output power 713 W 720 W Max.continuous output current 3.43 A(can be current limited to 2.66 A) 3.0 A(can be current limited to 2.4 A) Nominal output voltage/range 208/183-229 V 240/211-264 V Extended output voltage range 133/150/166-250 V 153/173/192-288 V Nominal frequency/range 60.0/59.3-60.5 Hz 60.0/59.3-60.5 Hz Extended frequency range 54.22-66.75 Hz2 54.22-66.75 Hz2 Power factor -0.6 to 0.6 programmable -0.6 to 0.6 programmable Maximum units per 30 A branch circuit 7(14 modules)/93(18 modules) 8(16 modules)/103(20 modules) Maximum output overcurrent protection 6.3 A Fuse; 12A peak for 30 uSec 6.3 A Fuse; 12A peak for 30 uSec EFFICIENCY CEC weighted efficiency 96.1% Peak inverter efficiency 96.7% Static MPPT efficiency(EN 50530) 99.5%-99.8% Night time power consumption 100 mW;Standby Reactive Current<200mA MECHANICAL DATA Ambient temperature range -40' C to+65' C Dimension(W x H x D)(Chassis only) 10"x 8"x 1.8" MC4 DC leads:8.75" Integrated branch cable:27" Weight 2 kg(4.4 Ibs) Enclosure ratin NEMA 6 FEATURES Communication Mesh Networked Power Line(130.2 kHz carrier) Monitoring Monitoring via CP-100 gateway and Online Cloud UL1741,IEEE std 1547,IEEE std C62.41.2,CSA C22.2 NO.107.1 CISPR 22 Class B; HECO Rule14H(Advanced Inverter),HECO Rule 22(Self-Supply) Certifications Rule 21/UL1741SA;Complies with NEC 690.12(B)(2)Rapid Shutdown Product Warranty 25 Years 2 x Series 60/72 Cell Mono or Poly PV modules 2 x Parallel HV Panasonic Modules;2 x Parallel 96/128 Cell SunPower Modules Compatibility(Single SKU) 'Maximum DC exposed voltage equals single module Voc when in shutdown Supports 50Hz operating in extended mode range(45.2-55.7 Hz) 3When current limited to 2.66A for 208V or 2.4A for 240V Ch ilicon ovver To learn more about Chilicon Power microinverters,call(310)800-1396 11 or visit chiliconoower.com IFT rok SUNIlt SunModo is focused on innovative racking and mounting solutions for professional installers in the fast-growing solar industry. Our solar mounting system features a patented grounding and bonding scheme that is designed into the mounting hardware for rails, clamps and splices. All self-grounding hardware meets NEC 690.43, UL27o3 Grounding and Bonding and UL17o3 Class-A Fire Rated for Type -land 2 PV modules tested by ETL. THE EZ ROOF MOUNT SYSTEM offers one of the most versatile,installer-friendly pitched roof mounting systems on the q market. Our patented easy-to-use flagship EZ Roof Mount anchor3ooMW Grounding in installed capacity. With a full range of I" Lug mounts and components,our pitched roof system can be configured in an endless variety of designs. In addition, Ez' SunModo offers a variety of mounts, Poor from shingle to metal roof,to best fit Mount your system needs and requirements. All system components have been UL27o3 tested by ETL for electrical continuity,eliminating the need for additional grounding hardware. Helio aluminum extrusions EZ Roof Mount with corrosion resistant Self-grounding Splice anodized coating Family �' st i ct w r Grounding Lug Portrait Mid Clamp Landscape Mid Clamp Landscape End Clamp UL 467 tested by ETL