Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
CITY OF TIGARD MASTER PERMIT IN a ,r- COMMUNITY DEVELOPMENT Permit#: MST2023-00392 Date Issued: 08/21/2023 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel 2S106AD05500 Jurisdiction: Tigard Site address: 16599 SW FRIENDLY LN Subdivision: RIVER TERRACE EAST Lot: 162 Project: Phandouangsy Project Description: Rooftop solar system 11.34 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $10,230.95 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckllw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'l 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O SvclFdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener. N All N Other: Y Other Description: Rooftop solar array 11.34 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF Vie R-3 0 Owner: Contractor: PHANDOUANGSY,VONE&ROCKY BRS FIELD OPS LLC Required Items and Reports(Conditions) 16599 SW FRIENDLY LN 1403 NORTH RESEARCH WAY BEAVERTON,OR 97007 OREM,UT 84097 PHONE: PHONE: 855-205-2530 FAX: Total Fees: $356.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR o57-nn1_nn1 n thrnunh(1 gF7_nn1_nnon , may n fain a rnnv of the mlae nr rlirart ni estinne to fll IMi'by Tallinn 5 1 919 l0R77 I Ann 3.7.991dd ,J,/,/�///�//p�j/�/ Issued By: Permittee Signature: I't P� j���,6�'/ !�i•/ L'/, / Call 5 3.639.4175 by 7:00 a.m.for the next available Inspection date. IIvV/ / This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. ` Buridin2 Permit Application Residential RECEIVE City of Tigard Receivedy: p ( 0 3 Prm:A,l��(-�b�j — Qo �Jef- ■ 13125 SW Hall Blvd.,Tigard,OR 97223 �U�7 .I 2U23 DataRov O Nt`+' 1 Plan Review Sti y 2 74,4_ Phone: 5n Line: 5 39 Fax: 503.598.1960 OF n R f' Other Permit CITY �I�rt�1U Date Read B furls: ® See Page 2 for r i c,.ti I:a Inspection 503.639.4175 y y, `, Internet: www.tigard-or.gov -3 L)ILD NG DIV S!n Notified/Method:45 / O"7.) Supplemental Information TYPE OF WORK REQUIRED 124.TA:1-AND 2-FAMILY DWELLING ❑ New constriction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all 0 Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. \` 0 1-and 2-family dwelling ElCommercial/industrial Valuation: $ 10,230.95 0 Accessory building 0 Multi-family Number of bedrooms: ❑Master builder 0 Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 16599 SW Friendly Ln, Beaverton, Oregon, 97007 New dwelling area: square feet City/State/ZIP: Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Vone Phandouangsy Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.: equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. x, {Rooftop Solar PV I I l 21Lc Valuation: $ Existing building area: square feet liNew building area: square feet ® PROPERTY OWNER 0 TENANT Number of stories: A. Name: Vone Phandouangsy Type of construction: Address: 16599 SW Friendly Ln, Beaverton, Oregon,97007 Occupancy groups: City/State/ZIP: Existing: 9) Phone: S ) Fax:( ) New: ❑ APPLICANT Ea CONTACT PERSON BUILDING PERMIT FEES* 0 Business name: BRS Field Ops, LLC {Please refer tofee schedule) -4- -- Structural plan review fee(or deposit): Contact name: Bryson Taylor FLS plan review fee(if applicable): Address: 1403 N Research Way City/State/ZIP: Orem, UT 84097 Total fees due upon application: Amount received: c Phone:( 385)482-0045 Fax::( ) ID E-mail: permitting.deparment@blueravensolaccom PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. U Business name: BRS Field Ops, LLC Submit two(2)sets of roof plan with connection details -- and fire department access,along with the 2010 Oregon Address: 1403 N Research Way Solar Installation Specialty Code checklist. City/Stale/ZIP: Orem, UT 84097 Permit Fee(includes plan review $180.00 and administrative fees): Phone:( 385)482-0045 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.: 227185 Total fee due upon application: $201.60 Authorized signature: This permit application expires if a permit is not obtained Brqfo PJq . _ Permitting Coordinator within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Print name: Bryson Taylor Date: 08/09/2023 Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application FOR OFFICE USE ONLY City of Tigard KeceivedDate/By. PermitiM.57,),0-J -Do 34.2., • 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Related Permit#: Inspection Line: 503.639.4175 Ready Date/By: Jails: I ® See Page 2 for HOARD J Internet: www.tigard-or.gov NotiticdMfethod: Supplemental Information TYPE OF WORK PLAN REVIEW ❑New construction iRi Addition/alteration/replacement I'Icavc check all that apply(submit 2 sets of plans ref Minn checked): ❑Service or feeder 400 amps or more ❑Building over three stories. E Demolition ❑Other: where the available fault current ❑Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. 0 I_and 2-family dwelling ❑Commercial/industrial ❑Accessory building less to ground or exceeds 14,000 ❑Commerc at-use agricultural amps for all other installations. buildings. ❑ Multi-family ❑ Master builder ❑Other: ❑Fire pump. ❑Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived ❑Addition of new motor load of system. Joh il: Joh site address: 16599 SW Friendly Ln, Beaverton, Oregon, a70UIIP or more. ❑"A","E,"l-2",'t-3 0 Six or more residential units. occupancy. City/State/ZIP: ❑Recreational vehicle parks. ❑Health-care facilities. Suite/bldg./apt.#: Project name: Vone Phandouangsy ❑Hazardous locations. 0 Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE Description 1 qt>. I Koch I Total I ' New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: • — Ea.add'1500 sq.ft.or ponion 33.42 1 DESCRIPTION OF WORK Limited energy,residential Rooftop Solar PV (with above sq.ft.) • 75.00 2 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy ❑ See Page 2 ® PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation Ntune: Vane Phandouangsy 200 amps or lest 100.70 2 Address: 16599 SW Friendly Ln, Beaverton, Oregon,97007 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation __— Owner installation:This installation is being made on property that I own which is not 200 amps or less 5936 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: _.. Date: 401 amps to 599 amps 168.54 2 Iu APPLICANT ❑ CONTACT PERSON Branch circuits—new,alteration,or extension, r er panel A.Fee for branch circuits with Business name: BRS Field Ops, LLC above service or feeder fee, 742 2 each branch circuit Contact name: Bryson Taylor B.Fee for branch circuits without Address: 1403 N Research Way service or feeder fee,first 56.18 2 branch circuit City/State/ZIP: Orem, UT 84097 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone: ( 385)482-0045 Fax: :( ) Each manufactured or modular dwelling,service and/or feeder 67.84 2 Email: permitting.department@blueravensolar.com • Reconnect only 67.84 2 •CONTRACTOR Pump or irrigation circle 67.84 2 Business name: BRS Field Ops, LLC Signor outline lighting 67.84 2 Address: 1403 N Research WaySignal circuit(s)or limited-energy ❑ See Page 2 2 panel,alteration,or extension. City/State/ZIP: Orem, UT 84097 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:( 385) 482-0045 Fax:( ) Investigation(1 hr min) 90.00/hr Email: permitting.department@blueravensolar.com Industrial plan (lfumin) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.: 227185 Electrical L' .: C1493 Suprv.Lic.: 6394S specifically listed(V hr min) ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal: Print name: Shan Whittaker Date: 08/09/2023 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: 1 /l/IOtt Taylor Permitting Coordinator TOTAL PERMIT FEE: This permit application expires if permit is not obtained within 180 Print name: Bryson Taylor Date: 08/09/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. PRoilding'Permits\ELC PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(I1/05/COM/WEB •Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE De • Fee for all residential systems combined: $75.00 Renews cription I Qty. Each rTotaly Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(1 hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00 Subtotal(Enter on Page 1): (SEE OAR 918-309-0000) ° Number of inspections allowed per permit. Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems n Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems El Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls El Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:lauilding\PermialELC_PermitApp_II R_LRE.doc Rev 06/17/2015 City of Tigard RECEIVED " Building Division U6 :i. 0 2023 • 1111 - 13125 SW Hall Blvd,Tigard, OR 97223 CITY OF TIGARD Phone: 503.718.2439 Fax: 503.598.1960 BUILDING DIVISION T I GARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 16599 SW Friendly Ln, Beaverton, Oregon, 97007 City: Zip: Owner's Name: Vone Phandouangsy Date: 08 / 09 / 2023 Contractor's Name: BRS Field Ops, LLC CCB #: 227185 Design Parameters of the Property/Structure If"Yes", does not Is the installation qualify for the Flood Hazard Located in a flood ❑ Yes prescriptive path, follow Area plain/flood way? 0 No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure 2 Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ❑Q Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ❑v Yes the prescriptive path. above ❑ No 1 I:Building/Fnrms/PhotoVolteic-Checklist02-01-11.docx Is the construction material wood and does Yes Type of If"Yes", qualifies for the construction qualify Construction as"conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? �/ If"Yes", qualifies for Pre-engineered trusses. ❑ Yes the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? If"Yes", qualifies for Nominal lumber. ❑ Yes the prescriptive path. ❑ No Is the combined weight © Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation ❑ layout in accordance Yes If"Yes", qualifies for with Section 305.4(3) of No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. © of composition shingle. Is the roof mounted © Yes Connections of solar assembly the solar assembly connected to roof No If"Yes",eiqpti e p for to the roof framing or blocking ❑ the prescriptive path. directly? 2 I:IBuilding/Forms/PhotoV oltaic-Checklist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 inches inches, qualifies for the directly to Maximum 60 inches prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? Yes the prescriptive path. ❑ No Is the roof decking of WSP min. t/z"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof © Yes the prescriptive path. surface. ❑ No 3 11Building/Forms/PhotoVoltaic-Checklist02-01-1 I.docx .. Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Solar Model Number: REC420AA PURE-R Listing Agency: UL 4 I JB uilding/Forms/Photo V oltai c-Checkli s t02-01-11.docx