Permit (103) CITY OF TIGARD MASTER PERMIT
s COMMUNITY DEVELOPMENT Permit#: MST2023-00423
Date Issued: 08/29/2023
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1S125DD09701
Jurisdiction: Tigard
Site address: 9620 SW VENTURA CT
Subdivision: WASHINGTON SQUARE ESTATES NO.3 Lot: 105
Project: Aznoe
Project Description: Rooftop solar PV system 10 kW with 200
amp service and (3)circuits.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 st Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf
Right: 0 Detectors:
Total: 0 sf Value: $10,000.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: Storm Sewer: 0
0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Other Fixtures: 0
Drywell-Trench Drain: 0 Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 3
Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+ampNolt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N
Other: Y Other Description: Rooftop solar array 10 kW Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR
SF VB R-3 0
Owner: Contractor:
AZNOE,CRAIG R&CATHERINE A SMART SOLAR ENERGY CO Required Items and Reports(Conditions)
9620 SW VENTURA CT 10940 SW BARNES RD STE 250
TIGARD,OR 97223 PORTLAND,OR 97225
PHONE: PHONE: 503-828-8064
FAX:
Total Fees: $493.90
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon I you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
oco-nnt-nnin thr I„h neP of•>-nm-n Yr.! „nht i.,z nnn,r„f fho n ilzc nr rlir«t ni izzlinm fn CV!tor kV rnun,n cn¢9zo 10517 nr+ann 499 9'1
dd
Rif
1 r lc/� t c:. �
Issued By: i Permittee Signature:
Call 503.639. 75 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the lob site at the time of each inspection.
Buildina Permit Application
r Residential RECEIVED FOR OFFICE USE ONLY
Received V n /1 �P Permit No.:Mn1�2 004/
City W Tigard Da a By. I UAt/ V r u/ S' J
III It • Phone S50 Hall ,Tigard,03. 97219 AUG 2 2 2�23 Plan Review Q )1r /1 /t other Permit.
Phone: 503.718.2439 Fax: 503.598.1960 Darcy: (((fff(�Il ]t}� 1 See Page i for
Inspection Line: 503.639.4175 CITY OF TIGARD Date Ready/By
TIGARD NonHedlMethod��� }7j Supplemental Information
Internet:
ww.tigard-or.gov BUILDING DIVISION
1
�ittu(r c� �Y✓4o^,
TYPE OF WORT{' `' ° 4s DDATA:I-AND 2-FAMILY DWELLING
0 New construction El Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
4 ❑Addition/alteration/replacement ' 0 Other: equipment,materials,labor,overhead,and the profit for the
- work indicated on this application.
--'' z�M`, CATEGORY OF CONSTRUCTION Valuation: $ 10,000.00
El 1-and 2-family dwelling ❑Commercial/industrial
Number of bedrooms:
❑Accessory building 0 Multi-family
Number of bathrooms:
❑Master builder 0 Other:
# Total number of floors:
., JOB 0 LOCATION 34r f„1,k:<„
Job site address. 9620 SW Ventura New dwelling area: square feet
City/State/ZIP: Tigard,Oregon 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name: Azone Residence Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Lot no.: Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
Tax map/parcel no 1 S 125DD09701 equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK`'rt .. I` ' work indicated on this application.
iL
:;
10.00kW Solar Roof Mount Installation Valuation $
Existing building area: square feet
New building area: square feet
❑ PROPERTY OWNER '" ❑ TENANT, : `*
Number of stories:
Name: Craig Azone Type of construction:
Address: 9620 SW Ventura Occupancy groups:
City/State/ZIP: Tigard,Oregon 97223 Existing:
Phone:( ) 925 321 5505 Fax.t ) New:
ts " " BUILDING PERMITFEKib*
�9 � ` a „, ❑ CONTACT PERSON. $ „i
�x�: : 4 a�,r.,> .,.�. ��,^-a'* • Illetoe refer to fee schedule) _
Business name: SMART SOLAR ENERGY CO Structural plan review fee(or deposit):
Contact name: Jenn Showers
FLS plan review fee(if applicable):
Address: 10940 SW BARNES RD#250 Total fees due upon application:
City/State/ZIP: PORTLAND,OR 97225
Amount received:
Phone:( ) 9713561593 Fax::( ) - - - . . '
T'HOTOVOLTAICSO ®:.bsa s r, ;,, ;.t,
E-mail: permitting@unity-solar.com
Commercial and residential prescriptive installation of
CONTRACTOR S roof-top mounted PhotoVoltaic Solar Panel System.
Business name: SMART SOLAR ENERGY CO Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address: 10940 SW BARNES RD#250 Solar Installation Specialty Code checklist.
PORTLAND,OR 97225 Permit Fee(includes plan review $180.00
City/State/ZIP: and administrative fees):
Phone:( ) 9713561593 Fax:( ) State surcharge(12%of permit fee): S21.60
CCB lie.: 234657 Total fee due upon application: $201.60
This permit application expires if a permit is not obtained
Authorized signature: within 180 days after it has been accepted as complete.
` 7/17/23 *Fee methodology set by Tri-County Building Industry
Print name: c lGft d Date: Service Board.
1:\Building\P ts\BUP-RESPermitApp.doc 02/24/2011 440_4613T(11/02/COM/WEB)
Electrical Permit Application FOR CPI.I ICE IISE ONLY
City of Tigard pi R
pil
■ 13125 SW Flail Blvd.,Tigard,OR 97223 Plan B MIZIMIT,� 1,/
Review Related Permit N:
r
Received
IIIII
Phone: 503.718.2439 Fax: 503.598.1960 Date
Inspection Line: 503.639.4175 Ready Date/By: tuns: El See Page 2 for
TIGARD Internet. www.tigard-or.gov Notified/Method. Supplemental Information
Please check alt that apply(submit 2 sets of plans wtitems checked):
El New construction ■ Addlhon/alterahon/teplaceme 0 Service or feeder 400 amps or more 0 Building over three stories.
❑ Demolition ❑Other: where the available fault current 0 Marinas and boatyards.
::: : 1. exceeds 10,000 amps at 150 volts or 0 Floating buildings.
<'r . � �TEGOR\' OF CONSTRUCTION ;;`s,,,.
' '^ less to ground,or exceeds 14,000 0 Commercial-use agricultural
'ME 1-and 2-family dwelli ❑Commercial/industrial ['Accessory building amps for all other installations. buildings.
❑Multi-family ❑Master builder ['Other: 0 Fire pump. ❑Installation of 150 KVA or
" ! a 'it ? s -, -°n :l'v CATION 0 Emergency system. larger separately derived
` '` ❑Addition of new motor load of system.
Job#: Job site address: 9620 SW Ventura 1001-1P or more. ❑"A","E","1-2^,"1.3",
occupancy.
Tigard,Oregon 97223 ❑Six or more residemial units. 0 Recreational vehicle parks.
City/State(LIP: ❑Health-care facilities.
❑Hazardous locations. 0 Supply voltage for more than
Suite/bldg./apt.#: Project name: Aznoe Residence ❑Sert ice or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: FEE SCHEDULE
Description I Qty. I Euca I -total l
New residential single-or multi-family dwelling unit.
-Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#: Ea.add't 500 sq.ft or portion 33.92 1
t -'`;'�» :tt-, ON ON WORK 'r.,'' Limited energy,residential 75.00 2
10.00kW Solar Roof Mount Installation (with above sq.ft.)
Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
_ Renewable Energy 0 See Page 2
p OWNER i', ❑-TENANTx s.'.i'`
,N ,�_;❑_,pg(�€�TX,. _ Services or feeders installation,alteration,and/or relocation
Name: Craig Aznoe 200 amps or less 1 100.70 2
201 amps to 400 amps 133.56 2
Address: 9620 SW Ventura 401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard,Oregon 97223 601 amps to 1,000 snips 301.04 2
Phone:( ) 925-321-5505 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email: craznoe@gmail.com relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signatu — _ COW Date: 401 amps to 599 amps 168.54 2
0.414W-165. ❑ COACT PE11SON
Branch circuits—new,alteration,or extension,per panel
�,v ,. A.Fee for branch circuits with
Business name: UNITY ELECTRICAL SERVICE LLC above service or feeder fee, 3 7.42 2
each branch circuit
Contact name: Clayton Tarkalson B.Fee for branch circuits without
15715 NE 42nd street service or feeder fee,first 56.18 2
Address: branch circuit
Vancouver WA 98682 Each add'l branch circuit 7.42 2
City/State/ZIP: Miscellaneous(service or feeder not included)
Phone:( ) 971-379-7380 Fax: :( ) Each manufactured or modular 67.84 2
dwelling,service and/or feeder
Email: permitting@unity-solar.com Reconnect only 67.84 2
`ti s CONTRACTOR.1;w `3 y: °s. Pump or irrigation circle 67.84 2
s
Business name: UNITY ELECTRICAL SERVICE LLC Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy ❑ See Page 2 2
Address: 15715 NE 42nd street panel,alteration,or extension.
Each additional inspection over allowable in any of the above
CiTy/State/ZIP: Vancouver WA 98682 Additional inspection(1 hr min) 66.25/hr
Phone:( ) 971-379-7380 Fax:( ) Investigation(I hr min) 90.00/hr
Industrial plant(1 hr min) 78.18/hr
Email: permitting@unity-solar.com Inspections for which no fee is
90 00r hr
C1599 s. crficall listed(Yhrmin`
CCB Lie.: 234553 Electrical Lie.: Suprv.Lia:4619S Y. -
,� ��, ;' "` ELECTRICAL PE' i�'� �€' ";�.,,. '=�`+
Suprv.Electrician signature,required: ,.—,..w... Subtotal:
Daniel Broughton Date: 7/17/23 0 Plan Review Required(25%of permit fee):
Print name: State surcharge(12%of permit fee):
TOTAL PERMIT FEE-
Authorized signature:
This permit application expires if a permit is not obtained within 180
Print name: ja,tia aalL Date: 7/17/23 days after it has been accepted as complete.
*
Number of inspections allowed per permit.
I:1Buildiog\Permits\ELC Pormit pp ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WES
Electrical Permit Application—City of Tigard
Page 2-Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENT _WORK QM FEE'sctwouE
Dea combined: $75.00 Renewablen °° an• I Each Ti°�
Fee for all residential systemsI
electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 1 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
❑ Garage Door Opener* >100 kva(fee in accordance 552.26 2
with OAR 918-309-0040)
❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
El Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr
charged at an hourly(1 hr min)
Inspections for which no fee is 90.001 hr
call listed %hrmin)
COMMERCIAL WORK ONLI'i �`�4'i *l , a ;Wf ,x t PERMIT FEES
` " "` '`"�' Subtotal(Enter on Page I)
Fee for each commercial system: $75.00 * Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
in Audio and Stereo Systems
U Boiler Controls
❑ Clock Systems
El Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
E Instrumentation
El Intercom and Paging Systems
n Landscape Irrigation Control*
E Medical
❑ Nurse Calls
El Outdoor Landscape Lighting*
❑ Protective Signaling
El Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
1:'.Boilding\Permits 0ELC_PermiApp_ELR_ERE.doc Rev 06/17/2015
City of Tigard
Building Division RECEIVED13125 SW Hall Blvd,Tigard,OR 97223
Phone: 503.718.2439 Fax: 503.598.1960
TIGARD Inspection Line: 503.639.4175 AUG 2 2 2023
www.tigard-or.gov
CITY OF TIGARD
BUILDING DIVISION
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 9620 SW Ventura
City: Tigard,Oregon Zip: 97223
Owner's Name: Craig Aznoe Date: 7/17/2023
Contractor's Name: Smart Solar Energy Co CCB #: 234657
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Located in a flood — prescriptive path, follow
Area plain/flood way? No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure (❑ Yes If"Yes", qualifies for
p "C" or less? E No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ❑ Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than 0�'�
,����!�� If"Yes", qualifies for
0 the prescriptive path.
above ❑
No
1:B ui I d ing/Form s/Photo V of t a l c-C heck l i st02-01-11.docx
Is the construction
Type of material wood and does CO Yes If"Yes", qualifies for
the construction qualify ❑ No the prescriptive path.
Construction as"conventional light
frame"construction?
Is the spacing 24 inches
orr less?
Pre-engineered trusses. [ I Yes If"Yes", qualifies for
�.- the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Is the combined weight c❑ Yes
of the PV modules and — If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation ��� �
01
layout in accordance ''�.�� If"Yes",qualifies for
with Section 305.4(3)of — No the prescriptive path.
the 2010 Oregon Solar
Code?
❑ Metal
Ingle layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
❑ of composition
shingle.
Is the roof mounted ❑ Yes
Connections of solar assembly If"Yes", qualifies for
the solar assembly connected to roof ❑ No the prescriptive path.
to the roof framing or blocking
directly?
2
I:Building/Forms/PhotoV oltaic-Checklist02-01-1 I docx
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes",qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes",qualifies for
E Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to 24 inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
s inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. 'V2" thickness, I I Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof ( Yes.) the prescriptive path.
surface. El No
3
I:Bui(ding/Form s/Photo V oltaic-Checkl ist02-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 1 I inches.
Attach a simple structural plan showing the roof framing(rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: SILFAB
Model Number: SILFAB SIL-400 HC+
Listing Agency: UL61730
4
I:Building/Fortns/Photo Voltai c-Checklist02-01-11.docx