HomeMy WebLinkAboutPermit (102) CITY OF TIGARD MASTER PERMIT
lig t. . COMMUNITY DEVELOPMENT Permit#: MST2023-00422
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/29l2023
Parcel: 1 S134BD08000
Jurisdiction: Tigard
Site address: 11652 SW PENN CT
Subdivision: PENN LAWN ESTATES Lot: 8
Project: Held
Project Description: Rooftop solar PV system 8 kW with 200 amp service and (2)circuits.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $10,000.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Bckftw Prevntr. 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits
1000 sf or less: 0 0-200 amp: 1 0-200 amp: 0 W/Svc or Fdr: 2
Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr:
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N
Other: Y Other Description: Rooftop solar array 8 kW Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
OTR SF VB R-3 0
Owner: Contractor:
HELD,ANDREW D&MOLLY D SMART SOLAR ENERGY CO Required Items and Reports(Conditions)
11652 SW PENN CT 10940 SW BARNES RD STE 250
TIGARD,OR 97223 PORTLAND,OR 97225
PHONE: PHONE: 503-828-8064
FAX:
Total Fees: $485.59
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon I to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
oc9-nn1-M1n thrni i OAR OF911111_nnon Jnn mmr n in n rnn,/of thu mane nr riirnrt ell i iectinnc to flu iNiC hi,reiilnn Sn 949 1(117 nr,,ff1 Ann 4'19 9'444
Issued By: // _ Permittee Signature: 7 e? e r l' e i D to
Call 503.639.417 y 7:00 a.m.for the next available inspection date. J
This permit card shall be ke in a conspicuous place on the job site until completion of the project.
Approved plans are required on the lob site at the time of each inspection.
. Building Permit Application
Residential ,OR OFFICE USE OvL5
RECEIVES R�;� q� �A ^
City of Tigard Date/By: I�� HIZ . by Permit No.: W1S l� 3 ,0/4f'�
_�i ' I3125 SW Hall Blvd.,Tigard,OR 97223^UG 22 2023 plan Review ito
v J w'vim
>s Phone: 503.718.2439 Fax: 503.598.I9 Datci8y: Other Permit:
Ti GAR t) Inspection Line. 503.639.4175 Date Ready/By: q Inds. VI See Page 2 for
Internet: www.tigard-or.gov r"'" "'ARO Notified/Method:� ( Supplemental Information
Q r1/4'f-2e(--7 - 11,1✓1
TYPE OF WORK CV4t ,td ¢,7 REQUIRED DATA:1-AND 2-FAMILY DWELLING
❑New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
C❑Addition/alteration/replacemenn ❑Other: equipment,materials,labor,overhead,and the profit for the
r'.: "- - 'otiTEGORY OF CONSTRUCTION work indicated on this application.
C____ -and 2-family dwelling __ __... 0 Commercial/industrial Valuation: $ 10,000.00
❑Accessory building 0 Multi-family Number of bedrooms:
El Master builder ❑Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address: 11652 SW Penn Court New dwelling area: square feet
City/State/ZIP: Tigard,Oregon 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name: Held Residence Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Lot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no.: 151346D08000 Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
8.00kW Solar Roof Mount Installation Valuation: $
Existing building area: square feet
New building area: square feet
❑ PROPERTY OWNER ❑ TENANT Number of stories:
Name: Molly Held Type of construction:
Address: 11652 SW Penn Court Occupancy groups:
City/State/ZIP: Tigard,Oregon 97223 Existing:
Phone:( ) 971-506-4018 Fax:( ) New:
0 APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES*
(Please refer to fee schedule)
Business name: SMART SOLAR ENERGY CO
Structural plan review fee(or deposit):
Contact name: Jenn Showers
Address: 10940 SW BARNES RD#250 FLS plan review fee(if applicable):
Total fees due upon application:
City/State/ZIP: PORTLAND,OR 97225
Phone:( ) 9713561593 Fax::( ) Amount received:
PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
E-mail: permitting@unity-solar.com
CONTRACTOR Commercial and residential prescriptive installation of
roof-top mounted PhotoVoltaic Solar Panel System.
Business name: SMART SOLAR ENERGY CO Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address: 10940 SW BARNES RD#250 Solar Installation Specialty Code checklist.
City/State/ZIP: PORTLAND,OR 97225 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:( ) 9713561593 Fax:( ) State surcharge(12%ofpermitfee): $21.60
CCB lie.: 234657
Total fee due upon application: $201.60
Authorized signature: This permit application expires it a permit is not obtained
within 180 days after it has been accepted as complete.
`� 7/17/23 *Fee methodology set by Tn-County Building Industry
Print name: �/(�'/�r/Q�},Q. Date: Service Board.
(:\Building\P \BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
Electrical Permit Application FOR OFFICE I SE ONI,v
City of Tigard Received
Pen o r I Date/ft : Permit It: K j ' 1
III • 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review
= Phone: 503.718.2439 Fax: 503.598.1960 Date/B : Related Permit#:
Inspection Line: 503.639.4175 Ready Date/By: luris: H See Page 2 for
1 I(--;:1121) Internet: www.tigard-orgov Notified/Method: Supplemental Information
- - PLAN REVIEW
❑New construction �t Addition/alteratiolt/rep)aceme Please check all that apply(submit 2 sets of plans w/items checked):
1� 0 Service or feeder 400 amps or more El Building over three stories.
I__I
❑Demolition Other: where the available fault current 0 Marinas and boatyards.
' z CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
<1-and 2-family dwelli ❑Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural
amps for all other installations. buildings.
❑Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION 0 Emergency system. larger separately derived
❑Addition of new motor load of system.
Job#: Job site address: 11652 SW Penn Court 100HP or more. ❑"A","E",'I-r',"I-3",
City/State/ZIP: Tigard,Oregon 97223 0 Six or more residential units. occupancy.
❑Health-care facilities. 0 Recreational vehicle parks.
Suite/bldg./apt.#: Project name: Held Residence 0 Hazardous locations. 0 Supply voltage for more than
O Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: FEE SCHEDULE
Description I Ors. I Each I Total I
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 1
DESCRIPTION OF WORK Limited energy,residential
8.00kW Solar Roof Mount Installation (with above sq.ft.) 75.00 2
Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
Renewable Energy ❑ See Page 2
❑ PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation
Name: Molly Held 200 amps or less 1 100.70 2
201 ampsto400amps 133.56 2
Address: 11652 SW Penn Court
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard,Oregon 97223 601 amps to 1,000 amps 301.04 2
Phone:( ) 971-506-4018 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email: heldfamilypdx@gmail.com
relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 _ 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signatu r Date: 401 amps to 599 amps 168.54 2
APPLICANTN ❑ CONTACT PERSON - Branch circuits—new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name: UNITY ELECTRICAL SERVICE LLC above service or feeder fee, 2
each branch circuit 7.42 2
Contact name: Clayton Tarkalson B.Fee for branch circuits without
Address:15715 NE 42nd street service or feeder fee,first 56.18 2
branch circuit
City/State/ZIP:Vancouver WA 98682 Each add'l branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:( ) 971-379-7380 Fax: :( ) Each manufactured or modular
Email: permitting@unity-solar.com
dwelling,service and/or feeder 67.84 2
Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name: UNITY ELECTRICAL SERVICE LLC Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy ❑ See Page 2 2
Address: 15715 NE 42nd street panel,alteration,or extension.
City/State/ZIP: Vancouver WA 98662 Each additional inspection over allowable in any of the above
Additional inspection(I hr min) 66.25/hr
Phone:( ) 971-379-7380 Fax:( ) Investigation(1 hr min) 90.00/hr
Email: permitting@unity-solaccom Industrial plant(I hr min) 78.18/hr
Inspections for which no fee is 90.00;hr
CCB Lie.: 234553 Electrical Etc.: C1599 Suprv.Lic.:46198 specifically listed('i hr min)
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,required: - Subtotal:
Print name: Daniel Broughton Date: 7/17/23 0 Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee):
Authorized signature: TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 190
�� 1Q�®,� 7/17/23 days after it has been accepted as complete.
Print name: ifj,"- f� Date: y P P
* Number of inspections allowed per permit.
MBuilding\Permits\ELC_Pmnit _ELR_ERE.doc Rev 06'17/2015 440.4615T(11/05/COM/WEB
` Electrical Permit Application—City of Tigard
Page 2-Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
DFee for all residential systems combined: S75.00 Renewable I Qty. I Each Total I
y Renwable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100 7o 2
5.01 to 15 kva 1 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
n Burglar Alarm 25.01 to 50 kva 301.04 2
❑ Garage Door Opener* 50.01 to 100 kva 552.26 2
>100 kva(fee in accordance 552.26 2
with OAR 918-309-0040)
❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva-no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed p/,hr min)
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES
Fee for each commercial system: 575.00 Subtotal(Enter on Page I).
(SEE OAR 918-309-0000) ` Number of inspections allowed per permit.
Check Type of Work Involved:
n Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
E Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
E Landscape Irrigation Control*
❑ Medical
n Nurse Calls
❑ Outdoor Landscape Lighting*
Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:\Building\Permits\ELC PetmttApp_ELR_ERE.dac Rev 06/t7/2015
r•
City of Tigard
Building Division
.11111
13125 SW Hall Blvd,Tigard, OR 97223 RECEIVED
Phone: 503.718.2439 Fax: 503.598.1960
TIGARD Inspection Line: 503.639.4175 AUG 22 2023
www.tigard-or.gov
CITY OF TIGARD
BUILDING DIVISION
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 11652 SW Penn Court
City: Tigard,Oregon Zip: 97223
Owner's Name: Molly Held Date: 7/17/2023
Contractor's Name: Smart Solar Energy Co CCB #: 234657
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? CI No s) OSSC or ORSC for
design requirements.
Is the wind exposure C❑ Yes If"Yes", qualifies for
Wind Exposure "C"or less? ❑ No the prescriptive path.
•
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes 4112110 the prescriptive path.
and/or their accessory
Ground structures. [ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes",pqrescriptive
p for
above the prescriptive path.
❑ No
LBuilding/Forms/Photo Voltaic-Checklist02-01-11.docx
Is the construction
material wood and does Cn Yes
Type of If"Yes", qualifies for
the construction qualify
Construction as "conventional light ❑ No the prescriptive path.
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ❑ Yes If"Yes",qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. 414111M. If"Yes",qualifies for
the prescriptive path.
❑ No
Is the combined weight ❑ Yes
of the PV modules and If"Yes",qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance 41111110 If"Yes", qualifies for
with Section 305.4(3) of
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of Cshinake
of woodone of the three types
material roofing materialgle/sh checked, qualifies for
Max. two layers the prescriptive path.
❑ of composition
shingle.
Is the roof mounted Cr! Yee
Connections of solar assembly
the solar assembly connected to roof No If"Yes",prescriptiveqp p for
to the roof framing or blocking ❑ the path.
directly?
2
IJB uilding/Forms/Photo Voltaic-Checklist02-01-11.docx
❑ Yes If"Yes",qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
❑ If"Yes", qualifies for
Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to 24 inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
18 inches qualifies for the
prescriptive path.
Minimum #10 at 24
inches o/c?
Size and spacing of if"Yes",qualifies for
fastener? ❑ Yes the prescriptive path.
No
Is the roof decking of
WSP min. '/2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members fl No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof Ye) the prescriptive path.
surface. ❑ No
3
C/Building/Forms/Photo Voltai c-Checklist02-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: SILFAB
Model Number: SILFAB SIL-400 HC+
Listing Agency: UL61730
4
I:Building/Forms/Photo Voltaic-Checklist02-O 1-11.docx