Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Plans
• OFFICE COPY RECEIVED t R-PANEL TABLE OF CONTENTS JUN 0 8 2023 Product Page No. Product Page No. I • _CII Panel Information Detail Conditions. R-Panel Profiles PRP-2 Eave Detail PRP-12 Panel Overview PRP-2 Sculptured Gutter Detail PRP-12 Valley Detail PRP-13 Flashing Profiles Sculptured Rake Detail PRP-13 Rakewall Detail PRP-14 Eave(Direct Fasten) PRP-3 Sculptured High Side Eave Detail PRP-14 Sculptured Gutter PRP-3 Endwall Detail PRP-15 Sculptured Gutter End PRP-3 Ridge/Hip Detail PRP-15 Universal Gutter/Downspout Strap PRP-3 Universal Ridge Detail PRP-16 Downspout PRP-3 Formed Ridge Detail PRP-16 95°Elbow PRP-3 Gravel Stop Detail PRP-17 Downspout Bracket PRP-3 R-Panel Outside Corner Detail PRP-17 Gutter Hanger PRP-3 R-Panel Inside Corner Detail PRP-18 Sculptured Corner Box PRP-3 Jamb Detail PRP-18 Sculptured Peak Box PRP-3 Head Detail PRP-19 Valley PRP-3 Base Detail PRP-19 R-Panel Sculptured Rake PRP-3 Sculptured Rake End PRP-3 Notes Pitch Break PRP-3 Sculptured High Side Eave PRP-3 Notes PRP-20 Counter Flashing PRP-4 Reglet Flashing PRP-4 20"Ridge/Hip PRP-4 Universal Ridge Cover PRP-4 ! -OFFICE COPY. - R-Panel Formed Ridge PRP-4 Vented Ridge Cover PRP-4 ' Vent Drip PRP-4 CITY OF '7[ TGARD - Gravel Stop PRP-4 REVIEWED FOR CODE COMPLIANCE R-Panel Inside Corner PRP-4 \ lV R-Panel Outside Corner PRP-4 Approved: ) Inside Corner PRP-4 Outside Corner PRP-4 OTC: [ I 1_5"Sill/Head PRP-4 - 1.5"Sill to Soffit PRP-4 Permit #: I 'F (�ao an 3- C) 73 1.25"Base PRP-4 Address: l R-Panel Jamb PRP-5 1,y-7 co .i"NeL aa.b01_ A / Head Channel PRP-5 Suite it: I Head/Jamb Cover PRP-5 R-Panel C-Closure PRP-541_......-- Date: Accessory Profiles R-Panel Closures PRP-6 Universal Closure PRP-6 R-Panel Light Transmitting Panel PRP-6 Vent Material PRP-6 Tube Sealant PRP-6 Tape Sealant PRP-6 VALIDITY OF PERMIT Rubber Roof Jack PRP-6 r §a Retro Roof Jack PRP-6 THE ISSUANCE OF A PERMIT Rubber Roof Flashing Kit PRP-6 BASED ON CONSTRUCTION Touch-Up Paint PRP-6 DOCUMENTS AND OTHER Continuousw Sc ee Vent PRP-6 DATA SHALL NOT PREVENT Louver with Screen PRP-6 R-Panel Shear PRP-6 THE CODE OFFICIAL FROM REQUIRING THE CORRECTION Testing Information OF ERRORS. OSSC 105.4 UL 580 Wind Uplift Information PRP-7 Section Properties and General Information....PRP-8-9 Design/Installation Considerations Fastener Installation Technique PRP-10 Condition of Substructure PRP-10 Fastening Information PRP-11 —++ �r19tal sa r ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 R �,!��m����T 800.406.7387(Corporate Office)•www.metalsales.us_com PRP-1 R-PANEL PANEL OVERVIEW R-PANEL PROFILE — 21/,e" i C H,1" 12„ 1 • - - 9/a" 35/15' - 17/16,. 36"Coverage _ -i PBR-PANEL PROFILE — 2'/,6" -C —j1" 12" _ i • 111a1/ 35/ta' - 1'/,6' 36"Coverage SLOPE The minimum recommended slope for any"R"and"PBR"-Panel is 1:12. Metal Sales recommends that in all roof applications sealant be used on sidelaps. SUBSTRATE R-Panel is designed to be utilized over open structural framing,but can easily be used with a solid substrate. The recommended substrate is'/e"plywood with a 30 pound felt moisture harrier. To avoid panel distortion,use a properly aligned and uniform substructure.PBR-Panel is recommended for roof applications. COVERAGE Each panel has a coverage of 36". LENGTH Lengths under 5'-0"are available with some cutting restrictions. Maximum recommended panel length is 45'-0". Longer panels require additional consideration in packaging,shipping,and erection. Please consult your Metal Sales branch for recommendations(see PGI-2 and PGI-3 for locations). AVAILABILITY Panels are available in 26,24,and 22 gauge. Minimums quantities may apply. APPLICATION Commercial,Industrial,and Architectural panels. PERFORMANCE TEST UL 580,UL 2218,UL 790,Texas Department of Insurance,Cantilever Diaphragm. FASTENING SYSTEM Direct Fastened(exposed). FASTENERS The fastener selection guide should be consulted for choosing proper fasteners for specific applications. Quantity and type of fastener must meet necessary loading and code requirements(see PGI-12-14). MATERIALS Steel grade 50 per ASTM A-792 Steel grade 80 per ASTM A-792 or ASTM A-653 FINISH ► 'Acrylic Coated Galvalume®(ACG)/ASTM A-792-AZ55 ► Prepainted Galvalume/ASTM A-792-AZ50 ► MS Colorfast4.5® ► "Fluorocarbon(PVDF) Differential appearance of Acrylic Coated Galvalume roofing materials is not a cause for rejection. '"Meets both Kynar 500 and Hylar 5000 specifications. PRP-2 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 800.406.7387(Corporate Office)•www.metalsales.us.com k. R-PANEL FLASHING PROFILES EAVE (DIRECT FASTEN) SCULPTURED GUTTER; SCULPTURED r1'I2" 1'/z'"'� GUTTER END 4/8 e.---- 'c-IT _y }�C 1 X 3'12" ' X X. 5172" -_- 150° 150° 5'/2' 31/2 ! 31/2" 105° '105° _. _ 5/8" N_ Hem 6" Length 10'-2"-"Specify Slope Angle Length 10'-2",20'-3"-*Specify Slope Angle DOWNSPOUT 6"x 4" 95°ELBOW 6"x 4" DOWNSPOUT STRAP 6" Hem 6" 4 \ -C /C 16" �\ "� Length 10%2",20'-3" 1 /` (Also available 4"x 3'/2) (Also available 4"x 31/2") DOWNSPOUT BRACKET SCULPTURED CORNER BOX C 135� 1'l2" /�� " 12„ / (Also available 4") SCULPTURED R-PANEL SCULPTURED PEAK BOX RAKE 6" I ,C 1'9--1 C— X= C Herrr 13/4" 105° 3'/2" 2" 150° /10 105° 3'/2" / _/ 2„ 2„ -Hem Length 10'-2", 20.-3"-*Specify Slope Angle Length 10'-2",20-3" SCULPTURED RAKE END Elle=3111 SCULPTURED HIGH SIDE EAVE •_C 105° X* Hem-` 105° 3'h" 150° 150° — 31/2" 1 105° 3/z" 6" 105° _' r 2„ i 2" 2' Hem Length 10'-2"-*Specify Slope Angle Length 10'-2",20'-3" ir' ""•>"gym "^metal sales ©Metal Sales Manufacturing Corporation!Subject to change without notice!Effective Date 9/11 800.406.7387(Corporate Office)•www.metalsales.us.com PRP-3 FLASHING PROFILES (CONT.) COUNTER FLASHING 20" RIDGE/HIP COVER C 1/2" la" �C 1" C 1" 10",;" 3la" i X`/ 2 \;"------ Hem 3/4" Hem Length 10.-2" Length 10'-2" Length 10'-2",20'-3"-*Specify Slope Angle UNIVERSAL RIDGE R-PANEL FORMED RIDGE VENTED RIDGE COVER COVER 2/2" 21/2"1 / A V A \ • j �C _3" / L , X\< ,36" 10" 18" \ . / Hemt/a" Length 10'-2"-*Specify Slope Angle *Specify Slope Angle Length 10'-2", 20'-3"-"Specify Slope Angle VENT DRIP GRAVEL STOP R-PANEL INSIDE CORNER 3/4' SVz" \ 1314" A/-F 60° X" 20° 4" C 111/4" \ 4" y _i =5/8" 3/81 Y Hem , Length 10'-2" Length 10'-2",20'-3"-*Specify Slope Angle Length 10'-2", 14'-2",20'-3" R-PANEL OUTSIDE INSIDE CORNER OUTSIDE CORNER CORNER 5" 5" 4" C —Hem C C- 5" 5" /\ 13/4" - Length 10.-2" 14'-2", 20'-3" Length 10'-2",20-3" Length 10.-2" 20'-3" 1.5" SILL/HEAD 1.5" SILL TO SOFFIT C C ,--_ —C 2/2" P/2" 21/2" 11/z" 25/t" 5/e 1// 1" /d' Ye /2" / , e Length 10'-2" Length 10'-2" Length 10'-2" ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 —+♦ PRP-4 B00.406.7387(Corporate Office)•www.metalsales.us.com I I a rra-•i•int!flittleS R-PANEL FLASHING PROFILES (CONT.) • R-PANEL JAMB HEAD CHANNEL HEAD/JAMB COVER Hem C 2'!B' C 3/e" 2'/2" i —7- 5/8" —... 81l8". C - 1 ye 1 13/e" 1 Length 7'-3", 10.-2", 14'-2" Length 10'-2" Length 10'-2", 14'-2" R-PANEL C-CLOSURE __ 1" 13/B" C C-Indicates color side of flashing. - 35Ig" Length 10-2" j(. meta' ©Metal Sales Manufacturing Corporation(Subject to change without notice(Effective Date 9/11 "..�.aa...�n m�n"nm 800.406.7387(Corporate Office)•www.metalsales.us.com PRP-5 R-PANEL ACCESSORY PROFILES R-PANEL CLOSURES UNIVERSAL CLOSURE TRANSMITTING PANEL 44.!4•42.E.441 a •-senmxxx+ NZOMMOY ;::°::; 36" 1"x 1'!2"x 50'Polyethylene Foam Synthetic Rubber 1"x 1'h"x 10'Polyethylene Foam 8 Ounce White Fiberglass 33/e '/s"X'/32"X 50' 10.3 oz.Cartridge Single Bead Urethane Butyl -Gray RUBBER ROOF JACK RETRO ROOF JACK RUBBER ROOF MS - FLASH KIT 41111111k ACV t �j tr MINI('/."to 1'/e"O.D.Pipe) �- � _ #2(1314"to 3"O.D. Pipe) \s,, #4(3"to 6"O.D.Pipe) #801asrso(a/a"to 2°/s"O.D.Pipe) #6(6"to 9"O.D.Pipe) #802Rrmo(2"to 7'4"O.D. Pipe) 12"x 50'-0"Flash Kit #8(7"to 13"O.D.Pipe) #803Rsnso(3'4"to 10"O.D.Pipe) 18"x 50'-0"Flash Kit TOUCH-UP PAINT CONTINUOUS RIDGE LOUVER WITH SCREEN ® VENT r am Available in pints PVDF/MS Colorfast45 9"x 10',12"x 10' 3'x 3',3'x 4' PRP-6 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 -+a 800.406.7387(Corporate Office)•www.metalsales.us.com I I ' ,,. ai, R-PANEL 1 im �3J an ( 111 % 11 i I T I(T-i n ii Ill( ,I Ijllll ilt p UULickLu u,wUl uc ) )( 603/16`Max I `3J • 1-, 2 t \ 3) i I q \ I( 1 � li (lIl( i ( IYi \ R-PANEL 1. Metal Roof Deck Panels*No.26 MSG min gauge coated steel.Panels continuous over two or more spans.End laps to Construction No.161 occur overpurlins withpanels overlapped a min of 4 in.with November 02,2001 aPPe lap centered over purlin web.A line of tape sealant may be used at panel side and end laps. Uplift-Class 90 Metal Sales Manufacturing Corporation"R-Panel""PBR-Panel". Fire Not Investigated 2. Panel Fasteners For panel to panel and panel to purlin connections to be No.12-14 by tin.self-drilling,self-tapping,hex head,plated steel screws with a 5i8 in.OD formed steel washer and a neoprene sealing washer. As alternate Fasteners-For panel to purlin connections, 1/4-14 HHAB self-tapping,plating steel screws,with a separate 5/8 in.OD dome shaped steel washer and a neoprene scaling washer may be used. Or:No. 14-101-IDA,self-tapping,plating steel screws,with a separate,5/8 in.OD dome shaped steel washer and a neoprene sealing washer may be used. Spacing,for panel-to-purlin connections to be 12 in.on center beginning 2-1/2 in.from center line on one side of each major rib.Spacing at end lap to be in a 5-7-5-7 in.pattern beginning 2-1/2 in.from the center line on both sides of each major rib. Fastener for panel to purlin connection to be 1-1/4 in.long when insulation(Item 3)is greater that 4-1/2 in. Spacing for panel-to-panel connections to be 20 in.on center with a fastener located in line with the purlin fasteners. 3. Insulation(Optional)-Any compressible blanket insulation 6 in.max thickness before compression. 4. Purlin No.16 MSG min gauge steel(50,000 psi min yield). 5. Lateral Bracing(Not shown)-As required. Refer to General information,Roof Deck Construction,(Roofing Materials and Systems Directory)for items not evaluated. *Bearing the UL Classification Mark. UL Underwriters Laboratories Inc. C LISTED "'I+i " ��metal sales g,Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 PRP-7 ,_^ -^,-,.r 800.406.7387(Corporate Office)•www.metalsales.us.com R-PANEL R-PANEL SECTION PROPERTIES AND GENERAL INFORMATION 21/16"- C 1" 4" 12" - 11/4' i • • 3/4 35115"-- 1'/18" -_ - 36" Coverage • SECTION PROPERTIES ALLOWABLE UNIFORM LOADS PSF (3 or More Dqual Spans) Top in Compression Bottom in Compression Inward Outward Width Yield Weight Ga. (in.) KSI PSF lxx Sxx Ixx Sxx Load Load Ire/ft In'/ft In4/fit Ina/ft 2' 3' 4' 5' 6' 7' 2' 3' 4' 5' 6' 7' 26 36" 80 0.87 0.0350 0.0348 0.0293 0.0439 235 119 71 47 27 17 270 132 77 50 35 26 24 36" 50 1.13 0.0543 0.0558 0.0427 0.0595 316 147 85 55 38 27 398 185 106 68 48 35 22 36" 50 1.45 0.0767 0.0814 0.0600 0.0790 434 199 113 73 51 37 594 273 155 100 70 51 1. •theoretical section properties have been calculated per AISI 2001"Specification for the Design of Cold-formed Steel Structural Members." Ixx and Sax are effective section properties for deflection and bending. 2 Allowable load is calculated in accordance with AISI 2001 specifications considering bending,shear,combined bending and shear,deflection,and applicable testing when available. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or fasteners/support connection and panel weight is not considered. 3. Deflection consideration is limited by a maximum deflection ratio of L/I80 of span. 4 Allowable loads do not include a 1/3 stress increase in uplift. ATTACHMENT DETAIL GENERAL INFORMATION ►Substructure • R-Panel is designed to be utilized over open structural • framing but can easily be used with a solid substrate. To #12-14 x 11/4"Self Driller avoid panel distortion use a properly aligned and uniform substructure. ►Coverage R-Panels are available in a 1'4"rib height with a coverage width of 36". 7\ ► Length Minimum factory cut length is 5'-0". Maximum recommended panel length is 45-0". Longer panels require additional consideration in packaging,shipping,and erection. Please consult Metal Sales for recommendations. ► Fasteners FASTENING PATTERNS The fastener selection guide should be consulted for choosing the proper fastener for specific applications. End of Panel Quantity and type of fastener must meet necessary loading and code requirements. NOTE:All panels are subject to surface distortion due to #12 14 x 1 t/4" Self Driller improperly applied fasteners. Overdriven fasteners will T t cause stress and induce oil canning across the face of the TF { panel at or near the point of attachment. ►Availability Finishes:Acrylic Coated Galvalume®,MS Colorfast45®, or various Kynar 500(PVDF)colors. Field of Panel Gauges:26ga and 24ga standard,22ga optional t #12-14 x 11/4"Self Driller I T 1 PRP-8 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 -+♦ ,�_+_. B00.406.7387(Corporate Office)•www.metalsales.us.com I — R-PANEL PBR-PANEL SECTION PROPERTIES AND GENERAL INFORMATION 36" Coverage 1 / — 12" 1„ a 3/4" 4" • -15/8"- 35/ts' SECTION PROPERTIES ALLOWABLE UNIFORM LIVE LOADS PSF (3 or More Equal Spans) Top in Compression Bottom in Compression Inward(Gravity/Deflection) Outward Uplift(Stress) Width Yield Weight __ (in.) KSI PSF lxx Sxx lxx Sxx Load Load _ In"/ft In'!ft In°/ft Ire/ft 2' 3' 4' 5' 6' T 2' 3' 4' 5' 6' 7' 26 36" 80 0.91 0.0360 0.0358 0.0313 0.0452 256 127 74 49 34 23 217 104 60 39 27 20 24 36" 50 1.17 0.0560 0.0578 0.0457 0.0613 330 153 88 57 39 29 314 145 83 53 37 27 22 36" 50 1.51 0.0800 0.0856 0.0633 0.0813 451 206 117 75 52 39 472 217 123 79 55 40 Theoretical section properties have been calculated per AISI 2001"Specification for the Design of Cold-formed Steel Structural Members." lxx and Sxx are effective section properties for deflection and bending. 2. Allowable load is calculated in accordance withAlSI 2001 specifications considering bending,shear,combined bending and shear,deflection,and applicable testing when available Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or fastenersisupport connection and panel weight is not considered. 3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span. 4. Allowable loads do not include a 1/3 stress increase in uplift. ATTACHMENT DETAIL GENERAL INFORMATION '/4"-14 x 7/8"Stitch Screw ► Slope The minimum recommended slope for PBR-Panel is 1:12. Metal Sales recommends that in all roof applications, #12-14 X 11/4" Self Driller sealants be used on all sidelaps with stitch screw 1'-0"on • center. ► Substructure PBR-Panel is designed to be utilized over open structural framing,but can easily be used with a solid substrate. To avoid panel distortion,use a properly aligned and uniform substructure. ►Coverage 'Tape Sealant(roof application) PBR-Panels are available in a 1'/a"rib height with a coverage width of 36". FASTENING PATTERNS IN. Length Minimum factory cut length is 5'-0". Maximum Field of Panel recommended panel length is45'-0". Longer panels x 7/8'Stitch Screw require additional consideration in packaging,shipping,and erection. Please consult Metal Sales for recommendations. #12-14 x 11/4"Self Driller l T t y T ► Fasteners The fastener selection guide should be consulted for •• choosing the proper fastener for specific applications. Quantity and type of fastener must meet necessary loading Tape Sealant(roof application) and code requirements. NOTE:All panels are subject to surface distortion due to Ends of Panel improperly applied fasteners. Overdriven fasteners will %1/4"-14 x'/e" Stitch Screw cause stress and induce oil canning across the face of the panel at or near the point of attachment. /#12-14 x 174" Self Driller Y y r { r T ►Availability � p''� � Finishes:Acrylic Coated Galvalume®,MS Colorfast45®, —"�1' ` or various Kynar 500(PVDF)colors. Gauges:26ga and 24ga standard,22ga optional Tape Sealant(roof application) �++1 metal sales ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 PRP-9 � " 800.406 7387(Corporate Office)•www.metalsales.us.com R-PANEL DESIGN / INSTALLATION CONSIDERATIONS FASTENER INSTALLATION TECHNIQUE Recommended Tool Type-Use depth locating nose or adjustable clutch on screw gun to prevent overdrilling and strip out. Do not use impact tools or runners. Seating the washer-Apply sufficient torque to seat the washer-do not overdrive the fastener. CORRECT TOO LOOSE TOO TIGHT Sealing material slightly Ws- Sealing material is not visible-- Metal washer deformed, ible at edge of metal washer not enough compression to sealing rnatenal pressed Assembly is watertight seal properly, beyond washer edge. w J LL ro cc U � To prevent wobbling-Make sure fastener head is completely engaged in the socket. If the head does not go all the way in the socket-tap the magnet deeper into the socket to allow full head engagement. Metal chips will build up from drilling and should be removed from time to time. Protect drill point-Push only hard enough on the screw gun to engage clutch. This prevents excess friction and burn out of the drill point. Correct pressure will allow screw to drill and tap without binding. Drilling through sheet and insulation-Ease up on pressure when drilling through insulation to avoid striking the purlin or girt with the point-apply more pressure after drill point contacts purlin or girt. Drilling through purlin overlaps-Drilling through lapped purlins requires extra care. Excessive voids between purlins sometimes damages drill points and two self-drillers might be necessary to complete the operation. It is sometimes advantageous to predrill. CONDITION OF SUBSTRUCTURE Whether over solid substrate or open structural framing,panel distortion may occur if not applied over properly aligned and uniform substructure. The installer should check the roof deck for squareness before installing "R"-Panels. Several methods can be used to verify squareness of the structure for proper installation of the panels. METHOD "A" -One method for checking the roof for squareness is to measure diagonally across one slope of the roof from similar points at the ridge and eave and obtain the same dimension. METHOD "S" -The 3-4-5 triangle system may also be used. To use this system measure a point from the corner along the edge of the roof at a module of three(3).Measure a point from the same corner along another edge at a module of four(4). Then by measuring diagonally between the two points established,the dimension should be exactly a module of five(5)to have a square corner. Multiple uses of this system may be required to determine building squareness. If the endwall cannot be made square,the roof system cannot be installed as shown in these instructions. i METHOD A 30 5�3 METHOD B 30 4 PRP-10 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 ++s f1191tal�IK 800.406.7387(Corporate Office)•www.metalsales.us.com I I ♦ ,..skrawwnkw-,m R-PANEL DESIGN I INSTALLATION CONSIDERATIONS (CONT.) _ R-PANEL WALL FASTENING PATTERN '/4"-14 x'/8"Stitch Screw(1'-0"o.c.) / / Tape Sealant(roof only) i / 1\,__/— R-Panel s fi T T T t � i R-Panel Fastening Pattern -Interior T t T T T T T t T 1 1 1 1 1 1 1 1 1 1 1 R-Panel Fastening Pattern-Ends PBR-PANEL ROOF FASTENING PATTERN 1/4"-14 x'/s" Stitch Screw(1'-0"o.c.) / Tape Sealant(roof only) ----- PBR-Panel ____/ 9 1 I 1 T 1t 1 1 1 PBR-Panel Fastening Pattern -Interior T t Y T T I I T t T 1 I I 1 1 I PBR-Panel Fastening Pattern - Ends j'i metal sa ©Metal Sales Manufacturing Corporation/Subject to change without notice!Effective Date 9/11 PRP 11 m�.,�y�m m�m��� 800.406.7387(Corporate Office)•www.metalsales.us.com R-PANEL EAVE DETAIL 1:12 Slope Minimum / Tape Sealant #12-14 x 11/2"SD (see below) R-Panel Inside Closure PBR-Panel Eave Tape Sealant jT ; #12-14 x 11/2" SD (see below) 1/a"-14 x 7/8'Stitch (every rib) \ � R-Panel Outside Closure - PBR-Panel -'lit'-14 x'/A"Stitch(1-0"o.c.) #12-14 x 1'/z"SD i f T T 1 T 1 1 r r ,F'h\l Tape Sealant(roof only) R-Panel Fastening Pattern R-PANEL SCULPTURED GUTTER DETAIL 1:12 Slope - PBR-Panel Minimum R-Panel Inside Closure Tape Sealant V4"-14 x 7/8"Stitch (1'-0"o.c.) -- . __ _ la" 14 x'/a"Stitch (1 per hanger) b r Sculptured Gutter :. III \\ Gutter Hanger \\\ #12-14 x 11/2"SD (see below) R-Panel Inside Closure Tape Sealant R-Panel -'la"-14 x'/a'Stitch(1-0"o.c.) I / #12-14 x 1'/2"SD 1 i t I Tape Sealant(roof only)' R-Panel Fastening Pattern PRP-12 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 +i metal 800 406.7387(Corporate Office)•www.metalsales.us.com + I ' ) R-PANEL VALLEY DETAIL 1:12 Slope —PBR-Panel Minimum / Tape Sealant i r � #12-14 x 1'/z"SD (see below) / / / / - Universal Closure ' / —Valley Plate // %/ / // / ,-Valley / r j A - J�- / / 11 / l r _\ / / i L\ -\ ! l / i i ' \ \ i% f 3" Minimum - \ �J' i I \_ r1/4%14 x'/s"(I-0"o.c.) , #12-14 x 1'/1"SD t / l 1 1 ( ! I 1 , 1 I J \_i _ Il-� i l Tape Sealant(roof only)/ R-Panel Fastening Pattern R-PANEL SCULPTURED RAKE DETAIL 1:12 Slope Minimum -- -- PBR-Panel / - -- #12-14 x 11/2" SD //// 1/4"-14 x 7/a"Stitch (1'-0"o.c.) - Tape Sealant / \� . Rake Angle J #12-14 x 1V2" SD (see below) R-Panel R-Panel Sculptured Rake R-Panel Outside Closure IPs #1/4-14 x 7/8"Stitch (every rib) - I I Tape Sealant '/-14 x'/e"Stitch(1'-0"o.c.) j- r#12-14 x V/2"SD I ! I I I 1 I T 1 T LEI _ Tape Sealant(roof only)j R-Panel Fastening Pattern 1ia'aa� ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 - aaw��� 800.406.7387(Corporate Office)•www.metalsales.us.corn PRP-13 R-PANEL RAKEWALL DETAIL 1:12 Slope Minimum / - #12-14 x 11/2" SD (see below) R-Panel Inside Closure Double Bead Tape Sealant Sculptured High Side Eave Rake Angle 1/4"-14 x'/a" (1'-0"o.c.) / Tape Sealant / / / PBR-Panel ' ' /r / / -74"-14 x'/e"Stitch(1'-0"o.c.) / r#12-14x1'/2'SD T I T T i 1 f 1 t 1 Tape Sealant(roof only)-' R-Panel Fastenina Pattern R-PANEL SCULPTURED HIGH SIDE EAVE DETAIL 1:12 Slope PBR-Panel Minimum #74-14 x 7/e" Stitch (every rib) Tape Sealant - R-Panel Outside Closure %/ / ;/ / Tape Sealant ' / ///�� Sculptured High Side Eave �— J j - #12-14 x 11/2" SD (see below) Tape Sealant jal" 1/4"-14 x'/8"Stitch (every rib) �l R-Panel Outside 14 x'/a"Stitch(1'-0"o.c.) Closure #12-14 x 1'/z SD , ' R-Panel T r I t } I 1 11 T. 1 1 %/ /� �� /' � Tape Sealant(roof only)- R-Panel Fastenina Pattern PRP-14 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 l 800.406 7387(Corporate Office)•www.metalsales.us.com -+vas,r�.,,,,�!„na m,m,-asales R-PANEL ENDWALL DETAIL 1:12 Slope Minimum R-Panel #12-14 x 11/2" SD (see below) R-Panel Inside Closure ,./„.„...„/,/� Tape Sealant /j Pitch Break 1/4"-14 x'/8' Stitch (every rib) Tape Sealant #12-14 x 11/2" SD (see below) j R-Panel Outside Closure // • - PBR-Panel / F'/a"-14 x'/e"Stitch(1'-0"o.c.) / ,' ,-#12-14 x 1V2"SD t / t 1 r t I I , T Tape Sealant(roof only)' R-Panel Fastening Pattern R-PANEL RIDGE/HIP DETAIL 1:12 Slope PBR-Panel Minimum - Tape Sealant R-Panel Outside Closure ' 1 i , / / #12-14 x 11/2" SD (see below) / �� ;/ / 1/4'-14 x'/a" Stitch (1'-0"o.c.) /' / / / / / R-Panel C-Closure (Optional) / / / // / / Tube Sealant / 20" Ridge/Hip Cover / / j Hip Plate /t i r'/a"-14 x 7/A"Stitch(1-0"o.c.) / ,-#12-14 x 11/2"SD / / I r T t } f 1 t t 1 Tape Sealant(roof only)-' R-Panel Fastenina Pattern j A eta'sales ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 PRP-15 ..,:,,�e�m.���. 800.406.7387(Corporate Office)•www.metalsales.us.com sigaggi UNIVERSAL RIDGE DETAIL 1:12 Slope ' Minimum / #12-14 x 11/2'SD (see below) PBR-Panel Outside Closure / / 1/4"-14 x 7/a"Stitch (every rib) / / / / ; •Tape Sealant j / 1 / /I / / I / Universal Ridge Cover l i i ii / I / // /j I / // i I ----, / i— r i 717 - -1- -1/'-14 x'/e"Stitch(1'-0"o.c.) ;/ r#12-14 x 1'/2"SD Tit T f 1 1 1 ' T ___:p\ I /-‘ I irI Tape Sealant(roof only) R-Panel Fastening Pattern R-PANEL FORMED RIDGE DETAIL 1:12 Slope PBR-Panel Minimum 1/4"-14 x 7/8"Stitch (every rib) #12-14 x 11/2"SD (see below) Tape Sealant R-Panel Formed Ridge Cover �1/4'"-14 x'/8"Stitch(1'-0"o.c.) / r#12-14 x 11h"SD 1 { 1 T i T T 1 r T lei _ �� I ice ' I.\l Tape Sealant(roof only)! R-Panel Fastening Pattern 800.406.7387(Corporate Office)•www.metalsales.us.corn -„.. .. l,sales PRP-16 ° Metal Sales Manufacturing Corporation/Subject to change without notice!Effective Date 9/11 -''`' nata • R-PANEL GRAVEL STOP DETAIL 1:12 Slope . Minimum / Fastener(by others) — Tape Sealant Gravel Stop R-Panel Outside Closure 1/4"-14 x 7/8"Stitch (every rib) Tape Sealant #12-14 x 11/2" SD (see below) R-Panel /' " 14 x 7/8"Stitch(1'-0"o.c.) - #12-14 x 1'/2"SD t { t t I r r t ! Tape Sealant(roof only) R-Panel Fastening Pattern R-PANEL OUTSIDE CORNER DETAIL R-Panel Outside Corner Ih 1/4'-14 x 7/8" Stitch (1'-0"o.c.) Tape Sealant R-Panel ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 PR P 1 �raa."m mmm.m 800.406 7387(Corporate Office)•www.metalsales.us.com R-PANEL INSIDE CORNER R-Panel Inside Corner / -s I_ / i '/4"-14 x 7/8"Stitch (1'-0"o.c.) Tape Sealant / i ' -- R-Panel / , / j it i R-PANEL JAMB DETAIL - ' ' R-Panel #12-14 x 172"SD (1'-0"o.c.) R-Panel Jamb : / C / Head/Jamb Cover PRP-18 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 ab aav m�� 800.406.7387(Corporate Office)•www.metalsales.us.com Ira i�m.jI - R-PANEL HEAD DETAIL R-Panel II ,� // #12-14 x 1V2"SD (see below) / R-Panel Inside Closure /� / - Tape Sealant / Head/Channel Head/Jamb Cover V4"-14 x'le"Stitch(1'-0"o.c.) #12-14 x 172"SD T t 1 t 1 1 1 t r 1 Tape Sealant(roof only)-' R-Panel Fastening Pattern R-PANEL BASE DETAIL /i ___/ I 1 / R-Panel i R-Panel Inside Closure Tape Sealant Mat ' • ; :i,`l #12-14 x 11/2" SD (see below) iiiill 'r- 11/4" Base ry."-14 x'la"Stitch(1'-0"o.c.) // it#12-14 x Viz"SD t i t I f I t i r 1 Tape Sealant(roof only)-! R-Panel Fastening Pattern w+. tea' ai ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 pRP-19 "x,•aa•,..n�ro•�..-• 800 406.7387(Corporate Office)•www.metalsales.us.com R=PANEL NOTES PRP-20 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 —a♦ mW-`-. sales 800.406.7387(Corporate Office)•www.metalsales.us.com I I -4n PBR-PANELCondensed Technical Reference 36" Coverage 12" `1 34" i-C I-4" F15/8 -1 —35/78'—' COMMERCIAL EXPOSED 36" MINIMUM OPEN FRAMING OR INDUSTRIAL FASTENED COVERAGE SLOPE SOLID SUBSTRATE PANEL 1:12 PANEL OVERVIEW ► Finishes: PVDF, MS Colorfast45®'and Acrylic-Coated Galvalume® ► Corrosion Protection:AZ55 per ASTM A 792 for unpainted Galvalume® AZ50 per ASTM A 792 for painted Galvalume® G90 per ASTM A 653 for Galvanized ► Gauges: 26 ga and 24 ga standard; 22 ga optional ► 36" panel coverage, 1'/4" rib height ► Panel Length: Minimum: 5'; Maximum: 45'recommended ► Exposed fastened metal building roof and wall system ► Trapezoidal rib on 12" centers ► Minimum roof slope: 1:12 ► Optional material availability: Bonderized TESTING AND APPROVALS ► UL 2218 Impact Resistance-Class 4 ► UL 790 Fire Resistance Rating-Class A,per building code ► UL 263 Fire Resistance Rating-per assembly ► ASTM E 1592 Structural Performance ► UL 580 Uplift Resistance-Class 90 Construction:4161 ► Texas Windstorm- Evaluations RC-198,RC-265 and RC-279 ► 2020 FBC Approvals-FL9482.4,FL10999.7 and FL14645.12 ► Miami-Dade County,Florida NOA 20-0331.02 -Wall expires 4/22/2025 ► Miami-Dade County,Florida NOA 20-0331.03 -Roof expires 4/22/2025 /±I metal sales ► ICC Evaluation Report- ESR-2385 1 manufacturing corporation PBR-PANEL Cechenced Technical Reference ATTACHMENT DETAIL FASTENER INFORMATION Side Lap Fastener Overdriven fasteners will cause panel distortions. Panel Fastener Fasteners should extend 1/2"or more past the inside face of the support material. Thick panels(ex. 18 ga)or supports(ex. 1/2"steel)may require predrilling of holes for screws. / Panel Fastener: Attaching to Wood: #10-14 XL Wood Screw Tape Sealant (roof application) Attaching to Steel: #12-14 XL Self Drilling Screw FASTENING PATTERNS Side Lap Fastener:Spaced 12"on center 1/4"-14 x 7/8"XL Stitch Screw Field of Panel Trim Fastener: Side LapFastener 1/4"-14 x 7/8"XL Stitch Screw {,-Panel Fastener q r r T t r Tape Sealant: s Single Bead:3/8 x 3/32 x 50'Roll Tape Sealant (roof application) Ends of Panel Side Lap Fastener ,Panel Fastener Tit Tape Sealant (roof application) SECTION PROPERTIES ALLOWABLE UNIFORM LIVE LOADS, psf For various fastener spacings Top in Compression Bottom in Compression Inward Load Outward Load Ga Width Yield Weight . in ksi psf lxx Sxx lxx Sxx in"ttt in'/ft in4/ft in'/ft 2' 3' 4' 5' 6' 7' 2' 3' 4' 5' 6' 7' 26 36 80 0.84 0.0367 0.0367 0.0317 0.0458 261 129 76 49 35 23 223 107 62 40 28 21 24 36 50 1.09 0.0560 0.0579 0.0457 0.0613 330 153 88 57 39 29 314 145 83 53 37 27 22 36 50 1 43 0.0800 0.0860 0.0633 0.0816 453 207 118 76 53 39 474 217 124 80 55 41 I. Theoretical section properties have been calculated per AISI 2016'North American Specification for the Design of Cold-Formed Steel Structural Members'. lxx and Sxx are effective section properties for deflection and bending. 2 Allowable load is calculated in accordance with AISI 2016 specifications considering bending,shear,combined bending and shear&deflection.Allowable load does not address web crippling,fasteners,support material or load testing.Allowable load considers the three or more equal spans condition.Panel weight is not considered. 3 Deflection consideration is limited by a maximum deflection ratio of Lit 80 of span. 4. Allowable loads do not include a 1/3 stress increase for wind. o N th U 0) 2 ,c metal sales Jacksonville,FL 800.394.4419 Seattle,WA 800.431.3470 manufacturing corporation metalsales.us.com Jefferson,OH 800.321.5833 Sellersburg,IN 800_9997777 Anchorage.AK 866.640.7663 Detroit Lakes,MN 888.594.1394 Mocksville,NC 800.228.6119 Sioux Falls,SD 888.299.0024 Bay City.,MI 888.777.7640 Fontana,CA 800.782.7953 Nashville,TN 800.251.8508 Spokane,WA 800.572.6565 Deer Lake,PA 800.544.2577 Fort Smith,AR 877.452.3915 Rock Island.IL 800.747.1206 Temple,TX 800.543.4415 Denver,CO 800.289.7663 Independence,MO 800.747.0012 Rogers. MN 800.328.9316 Woodland,CA 800.759.6019 R-PANEL TABLE OF CONTENTS Product Page No. Product Page No. Panel Information Detail Conditions R-Panel Profiles PRP-2 Eave Detail PRP-12 Panel Overview PRP-2 Sculptured Gutter Detail PRP-12 Valley Detail PRP-13 Flashing Profiles Sculptured Rake Detail PRP-13 Rakewall Detail PRP-14 Eave(Direct Fasten) PRP-3 Sculptured High Side Eave Detail PRP-14 Sculptured Gutter PRP-3 Endwall Detail PRP-15 Sculptured Gutter End PRP-3 Ridge/Hip Detail PRP-15 Universal Gutter/Downspout Strap PRP-3 Universal Ridge Detail PRP-16 Downspout PRP-3 Formed Ridge Detail PRP-16 95°Elbow PRP-3 Gravel Stop Detail PRP-17 Downspout Bracket PRP-3 R-Panel Outside Corner Detail PRP-17 Gutter Hanger PRP-3 R-Panel Inside Corner Detail PRP-18 Sculptured Corner Box PRP-3 Jamb Detail PRP-18 Sculptured Peak Box PRP-3 Head Detail PRP-19 Valley PRP-3 Base Detail PRP-19 R-Panel Sculptured Rake PRP-3 Sculptured Rake End PRP-3 Notes Pitch Break PRP-3 Sculptured High Side Eave PRP-3 Notes PRP-20 Counter Flashing PRP-4 Reglet Flashing PRP-4 20"Ridge/Hip PRP-4 Universal Ridge Cover PRP-4 R-Panel Formed Ridge PRP-4 Vented Ridge Cover PRP-4 Vent Drip PRP-4 Gravel Stop PRP-4 R-Panel Inside Corner PRP-4 R-Panel Outside Corner PRP-4 Inside Corner PRP-4 Outside Corner PRP-4 1.5"Sill/Head PRP-4 1.5"Sill to Soffit PRP-4 1.25"Base PRP-4 R-Panel Jamb PRP-5 Head Channel PRP-5 Head/Jamb Cover PRP-5 R-Panel C-Closure PRP-5 Accessory Profiles R-Panel Closures PRP-6 Universal Closure PRP-6 R-Panel Light Transmitting Panel PRP-6 Vent Material PRP-6 Tube Sealant PRP-6 Tape Sealant PRP-6 Rubber Roof Jack PRP-6 Retro Roof Jack PRP-6 Rubber Roof Flashing Kit PRP-6 Touch-Up Paint PRP-6 Continuous Ridge Vent PRP-6 Louver with Screen PRP-6 R-Panel Shear PRP-6 Testing Information UL 580 Wind Uplift Information PRP-7 Section Properties and General Information PRP-8-9 Design/installation Considerations Fastener Installation Technique PRP-10 Condition of Substructure PRP-10 Fastening Information PRP-11 ++�► I�,_` ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 PRP-1 800.406.7387(Corporate Office)•www.metalsales.us.com • R-PANEL PANEL OVERVIEW R-PANEL PROFILE - 2'/16" --C —1'•I— I— 4" — 12" • J/y' 35/16' 17/16' __. 36"Coverage PBR-PANEL PROFILE - - -2'/,6" ,--C Hi 4' 12" - 1 • --H 3°/ts - - 1 716' -- -- - - - 36"Coverage - - - - _: SLOPE The minimum recommended slope for any"R"and "PBR"-Panel is 1:12. Metal Sales recommends that in all roof applications sealant he used on sidelaps. SUBSTRATE R-Panel is designed to be utilized over open structural framing,but can easily be used with a solid substrate. The recommended substrate is 5/s"plywood with a 30 pound felt moisture barrier. To avoid panel distortion,use a properly aligned and uniform substructure.PBR-Panel is recommended for roof applications. COVERAGE Each panel has a coverage of 36". LENGTH Lengths under 5'-0"are available with some cutting restrictions. Maximum recommended panel length is 45'-0". Longer panels require additional consideration in packaging,shipping,and erection. Please consult your Metal Sales branch for recommendations(see PGI-2 and PGI-3 for locations). AVAILABILITY Panels arc available in 26,24,and 22 gauge. Minimums quantities may apply. APPLICATION Commercial,Industrial,and Architectural panels. • PERFORMANCE TEST UL 580,UL 2218,Lt.790,Texas Department of Insurance,Cantilever Diaphragm. FASTENING SYSTEM Direct Fastened(exposed). FASTENERS The fastener selection guide should he consulted for choosing proper fasteners for specific applications. Quantity and type of fastener must meet necessary loading and code requirements(see PGI-12-14). MATERIALS Steel grade 50 per ASTM A-792 Steel grade 80 per ASTM A-792 or ASTM A-653 FINISH ► 'Acrylic Coated Galvalume5(ACG)/ASTM A-792-AZ55 ► Prepainted Galvalume/ASTM A-792-AZ50 ► MS Colorfast455 ► "Fluorocarbon(PVDF) Differential appearance of Acrylic Coated Galvalume roofing materials is not a cause for rejection. "Meets both Kynar 500 and Hylar 5000 specifications. PRP-2 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 .a♦II ? m lamsaes800.406.7387(Corporate Office)•www.metalsales.us.com R-PANEL FLASHING PROFILES EAVE (DIRECT FASTEN) SCULPTURED GUTTER SCULPTURED ,,,\_11/2" 11/2"V GUTTER END 47/8" \ \ --( C , ! -- - ti C 1 X" 3'/2" Xs X" 150" 5'/Z 150° 51/2" 3'/2" 31/2" 105° 105° 5/8„ ' Hem _ _... _ 6" Length 10'-2"-`Specify Slope Angle Length 10'-2",20'-3"-*Specify Slope Angle DOWNSPOUT 6"x 4" 95°ELBOW 6"x 4" DOWNSPOUT STRAP Hem /6 4,� 6„ 4'\J l \ C r C 16"--., V Length 10'-2",20'-3" 1 /2' (Also available 4"x 372) (Also available 4"x 3'/) DOWNSPOUT BRACKET SCULPTURED CORNER BOX 7/ \ C �0 3�k11/z"� C=' \ / 12„ C 6" (Also available 4") SCULPTURED VALLEY R-PANEL SCULPTURED PEAK BOX RAKE 6„ C 1, - C Hem' /a/," 105° 31/2" X� IC � 10„ - 150° 105° 31/2" 2" Hem / Length 10'-2",20'-3"-°Specify Slope Angle Length 10'-2", 20'-3" SCULPTURED RAKE END SCULPTURED HIGH SIDE EAVE C �!, 105° ,6 372" 4" 105-° 3 1/2" X" Hem- - 150° 150° T C 3'/2. �- 105° 31/2" 105° �� 6" —; 2"-1 2 Hem Length 10'-2"-"Specify Slope Angle Length 10'-2", 20'-3" -++ niotal sales ©Metal Sales Manufacturing Corporation/Subject to change without notice!Effective Date 9/11 ( � + R=�y�m R�r 800 406.7387(Corporate Office)•www.metalsales.us.com PRP-3 R-PANEL FLASHING PROFILES (CONT.) COUNTER FLASHING 20" RIDGE/HIP COVER C� . '12" 1- s/s" �, C 1" C 3/ ' Xx/ 2 Hem 3/a Hem Length 10'-2" Length 10'-2" Length 10'-2",20'-3"-"Specify Slope Angle UNIVERSAL RIDGE R-PANEL FORMED RIDGE VENTED RIDGE COVER COVER /2'/2" vN 2'l2'a) C 3" '36 � Hem - /e" X"-.� 7/e" I 10" __ _ — 18' �' Length 10'-2"-`Specify Slope Angle "Specify Slope Angle Length 10'-2", 20'-3"-*Specify Slope Angle VENT DRIP GRAVEL STOP R-PANEL INSIDE CORNER 5'/2" -- 1/z" /` 1'/' I /a- \/-C �� 0° X" / I I" —C 4"120° 1'la" i C� 3'l4" ls" 3/8"'w Hem Length 10'-2" Length 10'-2",20'-3"-"Specify Slope Angle Length 10'-2", 14'-2",20'-3" R-PANEL OUTSIDE INSIDE CORNER OUTSIDE CORNER CORNER 4" I --C C C- Hem 5„ 5„ /i4„ 5/e — Length 10'-2", 14'-2",20'-3" Length 10'-2", 20'-3" Length 10'-2",20'-3" 1.5" SILL/HEAD 1.5"SILL TO SOFFIT EIMIZEIMIMIE— C z—C / C 25/e, 2'/2" ' 12" 1'/2" 1 h" 2 5 „ 3 1/2" /a `.... r, 43/.,' P/a„ Length 10'-2" Length 10.-2" Length 10'-2" ■_` PRP-4 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 j'" metal sates 800.406 7387(Corporate Office)•www.metalsales.us.com x•�.*=�^�n m�R�„,� R-PANEL FLASHING PROFILES (CONT.) HEAD CHANNEL HEAD/JAMB COVER 31/8 Hem-n 21/2" —C C 5/8' 2'/t' 8 /e' C-4 3 " 13/8" --1 1 /8 Length 7--3", 10'-2", 14'-2" Length 10'-2" Length 10'-2", 14.-2" R-PANEL C-CLOSURE — 1" 13/e" C C-Indicates color side of flashing. Length 10'-2" +++► me}a'sa ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 '� ",.,,,vd���,,.,".,r 800.406.7387(Corporate Office)-www.metalsales.us.com PRP-5 R-PANEL ACCESSORY PROFILES R-PANEL CLOSURES UNIVERSAL CLOSURE TRANSMITTING PANEL Outside Closure ,� ;/ ;,� ;�' d / i, i/ �' it ,+'' nA �'� �" 1, g � [i' / ' Inside Closure ,1 -'-"' , / ,, - 36" 1"x 11/2"x 50'Polyethylene Foam Synthetic Rubber 1"x 11h"x 10'Polyethylene Foam 8 Ounce White Fiberglass 331e - -/," _u :",12%.,., .,, 44.* ----`;'.41%.;•%..%•.i - N. *it: 318"X 313x"X 50' 10.3 oz.Cartridge Single Bead Urethane Butyl-Gray RUBBER ROOF JACK RETRO ROOF JACK RUBBER ROOF Iii& FLASH KIT , 4'4..,'Ito , MINI('/4"to 1'/e"O.D.Pipe) _ , #2(134'to 3"O.D.Pipe) ---��� #4(3"to 6"O.D.Pipe) #801nrrno('/a"to 23/4"O.D.Pipe) #6(6"to 9"O.D.Pipe) #802sE1no(2"to 71/4"O.D. Pipe) 12"x 50'-0"Flash Kit #8(7"to 13"O.D.Pipe) #80313E-mo(3'/4"to 10"O.D.Pipe) 18"x 50'-0"Flash Kit TOUCH-UP PAINT CONTINUOUS RIDGE LOUVER WITH SCREEN ® VENT MI . * r'"'"••••.....,..........„ Available in pints PVDF/MS Colorfast45 9"x 10',12"x 10' 3'x 3',3'x 4' 9) PR P-6 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 �+► 'sales 800.406.7387(Corporate Office)•www.metalsales.us.com Ira' met"' R-PANEL - 1 3�' 7,------- li l i' � rp( m I� l '(ni /I) ;lih (4) —-- > 603/16" Max �3% J ��, / 9I ��� // ,\ � , , , ; , ( , ), ,1i ) ,\ Il , � / ` / li % �\ li ,!I i ( iI 3J �4i ;2 i • R-PANEL 1. Metal Roof Deck Panels*No.26 MSG min gauge coated steel.Panels continuous over two or more spans.End laps to Construction No.161 occur over purlin with panels overlapped a min of 4 in.with lap centered over purlin web.A line of tape sealant may November 02,2001 be used at panel side and end laps. Uplift-Class 90 Metal Sales Manufacturing Corporation"R-Panel'"PBR-Panel". Fire Not Investigated 2. Panel Fasteners For panel to panel and panel to purlin connections to be No.12-14 by I in.self-drilling,self-tapping,hex head,plated steel screws with a 5/8 in.OD formed steel washer and a neoprene sealing washer. As alternate Fasteners-For panel to purlin connections,1/4-14 HHAB self-tapping,plating steel screws,with a separate 5/8 in.OD dome shaped steel washer and a neoprene sealing washer may be used. Or No. 14-10HHA,self-tapping,plating steel screws,with a separate,5/8 in.OD dome shaped steel washer and a neoprene sealing washer may be used. Spacing,for panel-to-purlin connections to be 12 in.on center beginning 2-1/2 in.from center line on one side of each major rib.Spacing at end lap to be in a S-7-5-7 in.pattern beginning 2-1/2 in.from the center line on both sides of each major rib. Fastener for panel to purlin connection to be 1-1/4 in.long when insulation(Item 3)is greater that 4-1/2 in. Spacing for panel-to-panel connections to be 20 in.on center with a fastener located in line with the purlin fasteners. 3. Insulation(Optional)-Any compressible blanket insulation 6 in.max thickness before compression. 4. Purlin No.16 MSG min gauge steel(50,000 psi min yield). 5. Lateral Bracing(Not shown)-As required. Refer to General Information,Roof Deck Construction,(Rooting Materials and Systems Directory)for items not evaluated. *Bearing the UL Classification Mark. jULUnderwriters Laboratories Inc.® LISTED ' metal sales ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 �•+-•�d�m�o��r PRP-7 800.406.7387(Corporate Office)•www.metalsales.us.corn R-PANEL R-PANEL SECTION PROPERTIES AND GENERAL INFORMATION i21/,6 --C 1" 4" 12" 11/4' //, 3/4" - —35I16" 17/16'. - -- 36" Coverage - SECTION PROPERTIES ALLOWABLE UNIFORM LOADS PSF (3 or More Equal Spans) Top in Compression Bottom in Compression Inward Outward Ga. Width Yield Weight - - — - — Load Load (in.) KSI PSF lxx Sxx IXx Sxx In"/ft In'/ft ln"/ft In'/ft 2' 3' 4' 5' 6' T 2' 3' 4' 5' 6' 7' 26 36" 80 0.87 0.0350 0.0348 0.0293 0.0439 235 119 71 47 27 17 270 132 77 50 35 26 24 36" 50 1.13 0.0543 0.0558 0.0427 0.0595 316 147 65 55 38 27 398 185 106 68 48 35 22 36" 50 1.45 0.0767 0.0814 0.0600 0.0790 434 199 113 73 51 37 594 273 155 100 70 51 1. Theoretical section properties have been calculated per AISI 2001"Specification for the Design of Cold-formed Steel Structural Members." lxx and Sxx are effective section properties for deflection and bending. 2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending,shear,combined bending and shear,deflection,and applicable testing when available. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or fasteners/support connection and panel weight is not considered. 3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span. 4. Allowable loads do not include a 1/3 stress increase in uplift. ATTACHMENT DETAIL GENERAL INFORMATION ► Substructure R-Panel is designed to be utilized over open structural framing but can easily be used with a solid substrate. To #12-14 x 11/4" Self Driller avoid panel distortion use a properly aligned and uniform substructure. ► Coverage R-Panels are available in a 14,"rib height with a coverage width of 36". • ► Length �� Minimum factory cut length is 5'-0'. Maximum recommended panel length is 45'-0". Longer panels require additional consideration in packaging,shipping,and erection. Please consult Metal Sales for recommendations. ► Fasteners FASTENING PATTERNS The fastener selection guide should be consulted for choosing the proper fastener for specific applications. End of Panel Quantity and type of fastener must meet necessary loading and code requirements. NOTE:All panels are subject to surface distortion due to #12 14 x 11/ " Self Driller improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the face of the T 1 ya T T T T panel at or near the point of attachment. ►Availability Finishes:Acrylic Coated Galvalume5,MS Colorfast45°, or various Kynar 500(PVDF)colors. Field of Panel Gauges:26ga and 24ga standard,22ga optional #12-14 x 11/4' Self Driller T f t T ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 j► metal sales PRP-8 800.406.7387(Corporate Office)•www.metalsales.us.com R-PANEL PBR-PANEL SECTION PROPERTIES AND GENERAL INFORMATION i -- 36" Coverage • - • 12" • 1„ • 11/4„ a/a C 4 • • F15/g"- _ 35/16" ALLOWABLE UNIFORM LIVE LOADS PSF SECTION PROPERTIES (3 or More Equal Spans) Top in Compression Bottom in Compression Inward(Gravity/Deflection) Outward Uplift(Stress) Ga. Width Yield Weight ----- Load Load (in.) KSI PSF lxx Sxx Ixx Sxx Ire/ft In'/ft In4/ft In3/ft 2' 3' 4' 5' 6' T 2' 3' 4' 5' 6' 7' 26 36" 80 0.91 0.0360 0.0358 0.0313 0.0452 256 127 74 49 34 23 217 104 60 39 27 20 24 36" 50 1.17 0.0560 0.0578 0.0457 0.0613 330 153 88 57 39 29 314 145 83 53 37 27 22 36" 50 1.51 0.0800 0.0856 0.0633 0.0813 451 206 117 75 52 39 472 217 123 79 55 40 I. Theoretical section properties have been calculated per AISI 2001 "Specification for the Design of Cold-formed Steel Structural Members." lxx and Sxx are effective section properties for deflection and bending. 2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending,shear,combined bending and shear,deflection,and applicable testing when available. Allowable load considers the worst case of 3 and 4 equal span conditions. Allowable load does not address web crippling or fasteners/support connection and panel weight is not considered. 3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span_ 4. Allowable loads do not include a 1/3 stress increase in uplift. ATTACHMENT DETAIL GENERAL INFORMATION 1/4"-14 x 7/8"Stitch Screw ► Slope The minimum recommended slope for PBR-Panel is 1:12. Metal Sales recommends that in all roof applications, #12-14 x 11/4" Self Driller sealants be used on all sidelaps with stitch screw 1'-0"on center. I ► Substructure PBR-Panel is designed to be utilized over open structural framing,but can easily be used with a solid substrate. To avoid panel distortion,use a properly aligned and uniform substructure. ►Coverage -Tape Sealant(roof application) PBR-Panels are available in a 11/,"rib height with a coverage width of 36". FASTENING PATTERNS ► Length Minimum factory cut length is 5'-0". Maximum Field of Panel recommended panel length is45'-0". Longer panels / 1/4'-14 X 7/8" Stitch Screw require additional consideration in packaging,shipping,and erection. Please consult Metal Sales for recommendations. / -#12-14 X 11/4" Self Driller f t r t ► Fasteners The fastener selection guide should be consulted for choosing the proper fastener for specific applications. Quantity and type of fastener must meet necessary loading 'Tape Sealant(roof application) and code requirements. NOTE:All panels are subject to surface distortion due to Ends of Panel improperly applied fasteners. Overdriven fasteners will 1/a'-14 x r/8,Stitch Screw cause stress and induce oil canning across the face of the panel at or near the point of attachment. ¢,-#12-14 x 1V4" Self Driller Tr r 1 T ►,Fin sihes:Acrylic Coated Galvalumea,MS Colorfast455, t r t y r • I I 1 or various Kynar 500(PVDF)colors. \ • Gauges:26ga and 24ga standard,22ga optional 'u-Tape Sealant(roof application) • 7,1 al sales ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 PRP-9 .a,,,ar..n 9,wM". 800.406.7387(Corporate Office)•www.metalsales.us.com R-PANEL DESIGN / INSTALLATION CONSIDERATIONS • FASTENER INSTALLATION TECHNIQUE Recommended Tool Type- Use depth locating nose or adjustable clutch on screw gun to prevent overdrilling and strip out. Do not use impact tools or runners. Seating the washer-Apply sufficient torque to seat the washer-do not overdrive the fastener. CORRECT TOO LOOSE TOO TIGHT Sealing material slightly vis- Sealing material is not visible: Metal washer deformed; ible at edge of metal washer not enough compression to sealing material pressed Assembly is watertight. seal properly beyond washer edgeCC W L. J A m � w U a - To prevent wobbling-Make sure fastener head is completely engaged in the socket. If the head does not go all the way in the socket-tap the magnet deeper into the socket to allow full head engagement. Metal chips will build up from drilling and should be removed from time to time. Protect drill point- Push only hard enough on the screw gun to engage clutch. This prevents excess friction and burn out of the drill point. Correct pressure will allow screw to drill and tap without binding. Drilling through sheet and insulation- Ease up on pressure when drilling through insulation to avoid striking the purlin or girt with the point-apply more pressure after drill point contacts purlin or girt. Drilling through purlin overlaps-Drilling through lapped purlins requires extra care. Excessive voids between purlins sometimes damages drill points and two self-drillers might be necessary to complete the operation. It is sometimes advantageous to predrill. CONDITION OF SUBSTRUCTURE Whether over solid substrate or open structural framing,panel distortion may occur if not applied over properly aligned and uniform substructure. The installer should check the roof deck for squareness before installing"R"-Panels. Several methods can be used to verify squareness of the structure for proper installation of the panels. METHOD "A" -One method for checking the roof for squareness is to measure diagonally across one slope of the roof from similar points at the ridge and eave and obtain the same dimension. METHOD "B" -The 3-4-5 triangle system may also be used. To use this system measure a point from the corner along the edge of the roof at a module of three(3). Measure a point from the same corner along another edge at a module of four(4). Then by measuring diagonally between the two points established,the dimension should be exactly a module of five(5)to have a square corner. Multiple uses of this system may be required to determine building squareness. If the endwall cannot be made square,the roof system cannot be installed as shown in these instructions. METHOD A 30 5j 3 METHOD B 30 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 PRP-10 800.406.7367(CorporateOffice)•www.metalsales.us.com I I rnemrnnmr"mlmr,na, R-PANEL DESIGN I INSTALLATION CONSIDERATIONS (CONT.) . R-PANEL WALL FASTENING PATTERN -- l/4"-14 x 7/8" Stitch Screw (1'-0"o.c.) Tape Sealant (roof only) / -=47 \ _- R-Panel i I T r I I r 1 1 1 R-Panel Fastening Pattern -Interior T r T 1 T T T T I I / 1 1 1 1 1 1 R-Panel Fastening Pattern -Ends PBR-PANEL ROOF FASTENING PATTERN l/4'14 x '/a" Stitch Screw(1'-0" o.c.) Tape Sealant (roof only) PBR-Panel Ti T T T It i / 1 1 PBR-Panel Fastening Pattern -Interior I t T I T I T T T T 1 1 1 1 1 1 PBR-Panel Fastening Pattern - Ends "'�''� tea' ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9l11 T r ,.,r,t,m.��5m.! 800.406.7387(Corporate Office)•www.metalsales.us.coni R-PANEL EAVE DETAIL 1:12 Slope Minimum / Tape Sealant #12-14 x 11/2" SD (see below) / R-Panel Inside Closure PBR-Panel — Eave Tape Sealant #12-14 x 11/2" SD (see below) " 'I4"-14 x'Is'Stitch (every rib) R-Panel Outside Closure PBR-Panel ,'l4"-14 x'le"Stitch(1'-0"o.c.) -#12-14 x 11/2"SD r r T r t r r r t r Tape Sealant(roof only)' R-Panel Fastening Pattern R-PANEL SCULPTURED GUTTER DETAIL 1:12 Slope PBR-Panel Minimum R-Panel Inside Closure — Tape Sealant {_ 1/4"-14 x'/e"Stitch (1'-0" o.c.) 2_„h 1/4%14 x'Is" Stitch (1 per hanger) _ I Sculptured Gutter 441�� - Gutter Hanger #12-14 x 1'/2" SD (see below) R-Panel Inside Closure Tape Sealant R-Panel w:"-14 x'/a"Stitch(1'-0"o.c.) /I - -#12-14 x 1'h"SD V / T I T I I r 1 T t 1 Tape Sealant(roof only)' R-Panel Fastening Pattern PRP-12 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 —++i I,rri.tal Salts 800.406.7387(Corporate Office)•www.metalsales.us.com �� ,�,.,,"�,m.m.,, R-PANEL VALLEY DETAIL 1:12 Slope PBR-Panel Minimum ---- Tape Sealant #12-14 x 11/2" SD (see below) Universal Closure Valley Plate Valley �� A� ; ; l �3" Minimum , / I A „I 1 HA"-14 x,A"(1'-0-o.c.) l , #12-14 x 1'/"SD l 1 1 t t t t t t t Tape Sealant(roof only)-' R-Panel Fastening Pattern R-PANEL SCULPTURED RAKE DETAIL 1:12 Slope Minimum PBR-Panel #12-14 x 11/2"SD '/4"-14 x 7/8"Stitch (1'-0"o.c.) Tape Sealant __ Rake Angle 91:'---1:'- #12-14 x 11/2" SD (see below) R-Panel R-Panel Sculptured Rake R-Panel Outside Closure #114-14 x 7/8" Stitch (every rib) ,[ A \ Tape Sealant `'/4'-14 x'!e'Stitch(1'-0"o.c.) / /-#12-14 x 1V2"SD t i t t t t 1 1 r t Tape Sealant(roof only) / R-Panel Fastening Pattern j I+ 1�'19ta�$� ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 pRP-13 „-:,,4, �.,�,Pj 800.406.7387(Corporate Office)•www.metalsales.us.com R-PANEL RAKEWALL DETAIL 1:12 Slope ' Minimum - #12-14 x 11/2" SD (see below) R-Panel Inside Closure j Double Bead Tape Sealant /�// Sculptured High Side Eave j Rake Angle % / 1/4"-14 x 7/8" (1'-0" o.c.) / % Tape Sealant �/ / PBR-Panel r'/4"-14 x 7/e"Stitch(1'-0"o.c.) / / #12-14 x 1'h"SD I 1 1 1 1 t ! T 1 r T Tape Sealant(roof only) / R-Panel Fastening Pattern R-PANEL SCULPTURED HIGH SIDE EAVE DETAIL 1:12 Slope PBR-Panel Minimum / / #V4-14 x 7/8"Stitch (every rib) / Tape Sealant / / / , R-Panel Outside Closure / / i % /; %/ / / i Tape Sealant la j Sculptured High Side Eave #12-14 x 1'/2"SD (see below) v Ili 1 Tape Sealant `J '/4"-14 x 7/8" Stitch (every rib) i. 1 - R-Panel Outside / Va'-14 x 7/a^Stitch(1'-0"o.c.) 1Closure / -#12-14 x 1'/2"SD R-Panel T I t t t I I t t I '� �� - '^ Tape Sealant(roof only)' R-Panel Fastening Pattern PRP-14 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 ++► , 800.406.7387(Corporate Office)•www.metalsales.us.com I I Via!.-.tl '1,—,M�+„ . ' R-PANEL ENDWALL DETAIL 1:12 Slope Minimum R-Panel ,-' #12-14 x 11/2"SD (see below) / - R-Panel Inside Closure ' �j�; - Tape Sealant i" - Pitch Break i j 1/4'-14 x'/8" Stitch (every rib) Tape Sealant �� #12-14 x 11/2"SD (see below) R-Panel Outside Closure • /,,,/ // PBR-Panel i ,-'/4'-14 x'/e"Stitch(1'-0"o.c.) / % r#12-14 x 1'/2"SD - 1 F/ 1 T I T 1 1 r t • s i Tape Sealant(roof only)-' R-Panel Fastening Pattern R-PANEL RIDGE/HIP DETAIL 1:12 Slope -- PBR-Panel Minimum Tape Sealant R-Panel Outside Closure #12-14 x 11/2" SD (see below) • 1/4"-14 x 7/9" Stitch (1'-0" o.c.) / / / , / - R-Panel C-Closure (Optional) / / / / , / Tube Sealant / % / 20" Ridge/Hip Cover / / / % i/ / ! / / / i / Hip Plate % / • • ,-'/4"-14 x'/e"Stitch(1'-0"o.c.) / r#12-14 x 1'/2"SD / / T F 1 1 1 T T T r T , . Tape Sealant(roof only) R-Panel Fastening Pattern ir. ©Metal Sales Manufacturing Corporation!Subject to change without notice!Effective Date 9/11 I �MtBlal Sales PRP-15 ::.n,.,:�,.-:..... 800 406.7387(Corporate Office)•www.metalsales.us.com R-PANEL UNIVERSAL RIDGE DETAIL 1:12 Slope ' Minimum #12-14 x 11/2"SD (see below) PBR-Panel Outside Closure 1/4"-14 x 7/8"Stitch (every rib) Tape Sealant Universal Ridge Cover / ' l !i i / / it i l ii ,-'/a"-14 x'/e"Stitch(1'-0"o.c.) / r#12-14 x 1'/z"SD / f i t 1 { 1 T T i t Tape Sealant(roof only)- R-Panel Fastening Pattern R-PANEL FORMED RIDGE DETAIL 1:12 Slope PBR-Panel Minimum 1/4"-14 x'/8'Stitch (every rib) #12-14 x 11/2"SD (see below) Tape Sealant R-Panel Formed Ridge Cover i -'/a"-14 x'/e"Stitch(1'-0"o.c.) / / ,r#12-14 x 11/7"SD T f 1 T 1 1 1 T r I i /'L _7-1 I /7. Tape Sealant(roof only) R-Panel Fastening Pattern PRP-16 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 -++1 'sal 800.406.7387(Corporate Office)•www.metalsales.us.com I I '�� •",,,,mow„r„�„ R-PANEL GRAVEL STOP DETAIL 1:12 Slope Minimum Fastener(by others) Tape Sealant / � Gravel Stop R-Panel Outside Closure • 1/4'-14 x'I' Stitch (every rib) Tape Sealant #12-14 x 11/2" SD (see below) R-Panel -'/a"-14 x'/e"Stitch(1'-0"o.c.) / / #12-14 x 11/2"SD 1 r r f r T r I r Tape Sealant(roof only)- R-Panel Fastening Pattern R-PANEL OUTSIDE CORNER DETAIL R-Panel Outside Corner II 1/4"-14 x 7/8" Stitch (1-0"o.c.) Tape Sealant R-Panel -�+i 11'1@tal ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 PRP-17 i ZI R.: :rm-,�:. 800.406.7387(Corporate Once)•www metalsales.us.com R-PANEL INSIDE CORNER R-Panel Inside Corner -, IIIli / - 1/4%14 x '/8' Stitch (1'-0"o.c.) / / / / Tape Sealant / R-Panel / / / /i / / II // I i T ; • v, R-PANEL JAMB DETAIL R-Panel #12-14 x 172" SD (I-0"o.c.) / R-Panel Jamb i \ - Head/Jamb Cover PRP-18 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 I>a 800.406 7387(Corporate Office)•www.metalsales.us.com 1 P�++�-1 a-wcM�n wAo R-PANEL HEAD DETAIL R-Panel #12-14 x 1'/2"SD (see below) 1 / / R-Panel Inside Closure i , , Tape Sealant X/' / / Head/Channel , itaws4 / Head/Jamb Cover 1/4"-14 x'/a"Stitch(1-0"o.n.) 412-14 X 1V2"SD T f 1 T 1 1 t T r Tape Sealant(roof only)-' R-Panel Fastening Pattern R-PANEL BASE DETAIL - R-Panel R-Panel Inside Closure r --- Tape Sealant IIV' ' #12-14 x lib"SD (see below) I Nil I / 11/4" Base r'/."-14 x'/a"Stitch(1'-0"o.c.) /� #12-14 x Viz"SD 1 f t 1 i 1 T T r t ? . N Tape Sealant(roof only)-' R-Panel Fastenina Pattern -";i Rietal ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 pRP-19 ��},." „sm.,,m..,:., 800 406 7387(Corporate Office)-www.metalsales.us.com R-PANEL NOTES PRP-20 ©Metal Sales Manufacturing Corporation/Subject to change without notice/Effective Date 9/11 114,1metal sales 800.406.7387(Corporate Office)•www.metalsales.us.com Rti��m,m-.M METAL WALL PANELS 07 42 13 , i i�Smetal sales SPECIFICATION DATA „,„,„, Metal Sales <, Manufacturing Corporation F1-1/2" This specification data sheet is provided by Metal r I I Sales Manufacturing Corporation as a technical 36"Coverage support tool incident to the sale of its IC72-Panel, 7/8" Corrugated and PBR-Panel metal panel prod- ,, " gated Panel ucts. Contact Metal Sales for more information on these and other products. F7/8" rz' " Telephone:800.406.7387 metalsales.us.com - 34-2/3"Coverage 1101 Section 07 42 13-METAL WALL PANELS PBR-Panel 144 tti 1. PRODUCT NAMES �1-tla" t2" - � x f, V IC72-Panel,7/8" Corrugated and PBR-Panel metal ,t 1 wall panels. 36"Coverage 2. MANUFACTURER Metal Sales Manufacturing Corporation 545 South 3rd Street,Suite 200 Louisville,KY40202 4. TECHNICAL DATA Silicon Valley Animal Center.Milpitas,CA Toll Free:800.406.7387 Applicable Standards Phone:502.855.4300 Approvals: •ASTM A 653 - Standard Specification for Steel Fax 502.855.4200 Sheet,Zinc-Coated(Galvanized)or Zinc-Iron Alloy- 2020 State of Florida Building Code: Web:metalsales.us.com Coated(Galvannealed)by the Hot-Dip Process. •Approval 9482.1. (Applies to 7/8" Corrugated E-Mail:rgage@metalsales.us.com •ASTM A 792 - Standard Specification for Steel product). 3. PRODUCT DESCRIPTION Sheet, 55% Aluminum-Zinc Alloy-Coated by the •Approval 9482.4.(Applies to PBR-Panel product). Basic Use Hot-Dip Process. Miami-Dade County Approval: NOA 20-0331.02. For more than 55 years, Metal Sales has earned a •ASTM A 1011 -Standard Specification for Steel, (Applies to PBR-Panel product). reputation as the premier provider of metal building Sheet and Strip, Hot-Rolled, Carbon, Structural, components and accessories. Metal Sales main- High-Strength Low-Alloy, High-Strength Low-Alloy ICC-ES Evaluation Report: ESR-2385. (Applies to tains the industry's largest professional sales and with Improved Formability,and Ultra-High Strength. IC72-Panel product, 7/8" Corrugated product and service team, supported by 21 branches located PBR-Panel product). throughout the United States and offers a full line •ASTM D 2244-Standard Practice for Calculation P ) of high quality metal roof and wall panels for ag- of Color Tolerances and Color Differences from In- strumentally Measured Color Coordinates. Physical Properties: ricultural, commercial, architectural, industrial and Test reports are available to design professionals residential projects of every shape and size for both •ASTM D 4214-Standard Test Methods for Evalu- upon request. new construction and retrofit applications. Metal ating the Degree of Chalking of Exterior Paint Films. Note: Industry designation for material thickness is Sales is dedicated to leading the metal building .ASTM E 84-Standard Test Method for Surface moving away from"gauge"to decimal thickness in component industry, by setting new standards for Burning Characteristics of Building Materials. inches.Metal Sales recommends use of a minimum operating efficiency, product design, active service thickness requirement of 0.018-inch (0.46-mm) in- management and lasting value. •ASTM E 283-Standard Test Method for Determin- stead of 26 gauge, 0.0236-inch(0.60-mm) instead ing Rate of Air Leakage Through Exterior Windows, of 24 gauge, 0.0296-inch (0.75-mm) instead of 22 Manufacturer Memberships and Affiliations Curtain Walls,and Doors Under Specified Pressure gauge,0.0356 inch(0.904 mm)instead of 20 gauge CRRC-Cool Roof Rating Council Differences Across the Specimen. and 0.0466 inch (1.184 mm) instead of 18 gauge. MCA-Metal Construction Association •ASTM E 331- Standard Test Method for Water For Galvalume, specify AZ50 for painted mate- CSI-Construction Specifications Institute Penetration of Exterior Windows, Skylights, Doors, riat or AZ55 for unpainted material. For galvanized, NRCA-National Roofing Contractors Association and Curtain Walls by Uniform Static Air Pressure specify G90. ENERGY STARO Partner Difference. Underwriters Laboratories(UL): Technical Properties for IC72-Panel Products: ►Panel coverage 36 inches(914.4 mm). •UL 263 - Fire Tests of Building Construction and ►Rib Height: 1-1/2 inches(38.1 mm). Materials. Pi-Material: Aluminum-zinc alloy-coated or zinc- Metal Sales Manufacturing Corporation metalsales.us.com 1 METAL WALL PANELS 07 42 13 I �� mmfeuring tal sales SPECIFICATION DATA I coated steel sheet, AZ50, AZ55 or G90 coating designation, structural quality, Grade 50 or Grade 33,0.0236-inch(0.60-mm),0.0296-inch(0.75-mm), 0.0356 inch (0.904 mm) and 0.0466 inch (1.164 mm) minimum thickness. Not all thicknesses are produced at all branches. le Attachment:Exposed,direct-fastened panel. ►Application: Designed for application over open e i r;-_ framing or solid substrate. "I ; ( �-, 4 le-Rib Configuration:Trapezoidal. , i�� le Surface Finish: PVDF (Kynar 500) or Acrylic- �ss `-- � Coated Galvalume. ►Color: Contact Metal Sales for information on - color availability. le-Testing: Fire Resistance Rating: Complies with • ,, Ili n IU�t�� 7 "" ' I r �1 i� k�V' t 5 Air Leakage:0.0148 cfm/sq.ft.when tested accord- ing to ASTM E 283. Water Penetration: None at 6.24 psf when tested w_. •. according to ASTM E 331. le Approvals: Code and Testing Agency Approvals: ICC-ES Evaluation Report:ESR-2385. Silicon Valley Animal Center,Milpitas,CA Technical Properties for 718" Corrugated Prod- designation,structural quality,Grade 50,0.018-inch recommendations.Deliver materials in manufactur- ucts: (0.46-mm), 0.0236-inch (0.60-mm) or 0.0296-inch er's original,unopened,undamaged containers with le Panel coverage:34-2/3 inches(880.5 mm). (0.75-mm)minimum thickness. identification labels intact. Store materials above le-Rib Height 7/8 inch(22.2 mm). ►Attachment:Exposed,direct-fastened panel. ground, under waterproof covering, protected from le Material: Aluminum-zinc alloy-coated or zinc- le Application: Designed for application over open exposure to harmful weather conditions and at tem- coated steel sheet, AZ50, AZ55 or G90 coating framing or solid substrate. perature and humidity conditions recommended by designation, structural quality, Grade 50 or Grade le Rib Configuration:Trapezoidal. manufacturer. Provide proper ventilation of metal 33, 0.018-inch (0.46-mm), 0.0236-inch (0.60-mm), le-Surface Finish: MS Colorfast45, PVDF (Kynar panel system to prevent condensation build-up 0.0296-inch (0.75-mm) or 0.0356 inch (0.904-mm) 500)or Acrylic-Coated Galvalume. between each panel and trim or flashing compo- minimum thickness. le Color: Contact Metal Sales for information on nent. Tilt stack to drain in wet conditions. Remove lee Attachment:Exposed,direct-fastened panel. color availability. strippable plastic film before storage under high- le-Application: Designed for application over open Ile Testing: Fire Resistance Rating: Complies with heat conditions. Store products in manufacturer's framing or solid substrate. UL 263. unopened packaging until just prior to installation. le-Rib Configuration:Sinusoidal. le Approvals: Code and Testing Agency Approvals: Exercise caution in unloading and handling metal le-Surface Finish: MS Colorfast45, PVDF (Kynar Complies with Miami-Dade County Approval NOA panel system to prevent bending,warping,twisting 500)or Acrylic-Coated Galvalume. 20-0331.02. Complies with 2020 State of Florida and surface damage. lie Color: Contact Metal Sales for information on Building Code Approval:9482.4.ICC-ES Evaluation color availability. Report:ESR-2385. Preparation Ile Testing: Fire Resistance Rating: Complies with Install furring, angles, sub-purlins, and other mis- UL 263. Environmental Considerations cellaneous wall panel support members and anchor Air Leakage:0.004 cfm/sq.ft.when tested accord- Construction metals generally are readily recyclable according to metal wall panel manufacturer's rec- ng to ASTM E 283. at the end of their service life. The raw materials ommendations. Ensure panel support is in-plane. iWater Penetration: None at 12 psf when tested ac- used in manufacture of metal wall panels also come Limit in-plane variance to no more than a total of cording to ASTM E 331. from recycled sources. Pre-consumer and post- 1/4 inch(6mm)on 10 feet(3.05 m). le Approvals: Code and Testing Agency Approvals: consumer recycled content varies. Consult with Complies with 2020 State of Florida Building Code manufacturer for more information. Thermal Insulation Installation Approval 9482.1. ICC-ES Evaluation Report: ESR- Install polyethylene vapor retarder if required. In- 2385. Fire Performance stall blanket insulation if required, in compliance Flame-Spread Index: 25 or less (Class A) or 200 with installation requirements in Division 07 Section Technical Properties for PER-Panel Products: (Class C). Thermal Insulation,' ►Panel coverage:36 inches(914.4 mm). 5.INSTALLATION le Rib Height: 1-1/4 inches(31.8 mm). Handling and Storage Ile Material: Aluminum-zinc alloy-coated or zinc- Handle and store product according to Metal Sales coated steel sheet, AZ50, AZ55 or G90 coating 2 metalsales.us.com Metal Sales Manufacturing Corporation • METAL WALL PANELS 07 42 13 manufacturing sales SPECIFICATION DATA Metal Wall Panel Installation Building Codes 8.MAINTENANCE Verify that site conditions are acceptable for installa- Current data on building code requirements and No specific maintenance is required for properly Lion.Do not proceed with installation until unaccept- product compliance may be obtained from Metal installed Metal Sales wall panel products. Periodic able conditions are corrected. Comply with panel Sales technical support specialists. Installation panel inspection to verify system integrity,drainage manufacturer's installation instructions including must comply with the requirements of authority hav- functionality and repair of storm damage is advised. but not limited to special techniques, interface with ing jurisdiction. other work and integration of systems. Fasten met- 9.TECHNICAL SERVICES al wall panels to supports with concealed clips at 6.AVAILABILITY AND COST Technical assistance, including more detailed infor- each standing-seam joint at location, spacing and Availability mation, product literature,test results, project lists, using proper fasteners as recommended by panel Metal Sales products are nationally distributed and assistance in preparing project specifications and manufacturer. Comply with installation tolerances supported from 21 convenient locations nationwide, arrangements for application supervision, is avail- as required. including Alaska. Manufacturer has the ability to able by contacting Metal Sales. ship worldwide. Contact manufacturer for informa- Accessory Installation tion on local availability. 10.FILING SYSTEMS Install accessories using techniques recommended Cost Additional product information is available from the by manufacturer and which will assure positive Budget installed cost information may be obtained manufacturer upon request. Metal Sales product anchorage to building and weather tight mount- from a local Metal Sales distributor or directly from information may be found online metalsales.us.com ing. Provide for thermal movement. Coordinate the manufacturer. installation with flashings and other components. For Flashing and Trim, comply with performance 7.WARRANTY requirements, manufacturer's written installation Special Exposed Panel Finish Warranty: Manufac- instructions and the SMACNA°Architectural Sheet turer's standard form PVDF(Fluorocarbon System) Metal Manual."Provide concealed fasteners where Warranty for film integrity, chalk rating and fade possible, and install units to true level. Install work rating in which manufacturer agrees to repair or with laps,joints and seams that will be permanently replace panels that show evidence of deteriora- watertight. tion within specified warranty period. Deterioration shall include, but is not limited to, color fading of Field Quality Control more than 5 Hunter units when tested according to If requested by Owner,provide manufacturer's field ASTM D 2244,chalking in excess of a No.8 rating service consisting of product use recommendations when tested according to ASTM D 4214 or crack- and site visits for inspection of product installation in ing, checking, peeling or failure of paint to adhere accordance with manufacturer's instructions, to bare metal. Warranty Period for film integrity is 45 years and for chalk and fade rating is 35 years. , Precautions,Cleaning and Protection Metal Sales warranty excludes surface deteriora- Touch-up paint is used to cover and protect unex- tion due to physical damage and exposure to salt petted scratches on the paint finish that may occur air environments. during installation of panel.Touch-up paint will not Special Exposed Panel Finish Warranty: Manufac- weather as well or at the same rate as the original turer's standard form (MS Colorfast45) proprietary system.Test in an area that will not be noticeable. two coat roll coated System Warranty for film integ- i Metallic paint colors are available at an additional rity, chalk rating and fade rating in which manufac- charge. Minor differences in color and appearance turer agrees to repair or replace panels that show mr are normal and to be expected. evidence of deterioration within specified warranty To minimize possible differences in appearance, period. Deterioration shall include, but is not lim- 'R ., an entire project should be painted at one time, ited to, color fading of more than 5 Hunter units on from one batch of paint, using the same apphca- vertical applications or more than 6 Hunter units N tion equipment.Additionally, fabricated panels, flat on non-vertical applications when tested accord- sheet and flashings should be oriented in the same ing to ASTM D 2244, chalking in excess of a No. • direction. 8 rating on vertical applications or a No.7 rating on - After installation remove temporary coverings and non-vertical applications when tested according to • protection of adjacent work areas.Repair or replace ASTM D 4214,cracking,checking,peeling or failure any installed products that have been damaged. of paint to adhere to bare metal or perforation.War- Clean installed panels in accordance with manu- ranty Period for film integrity is 45 years,chalk and facturer's instructions prior to Owner's acceptance. fade rating for 30 years and perforation for 25 years Remove and lawfully dispose of construction debris for AZ50 material. Metal Sales warranty excludes from Project site. Protect installed product and fin- surface deterioration due to physical damage and ish surfaces from damage during construction. exposure to salt air environments. Silicon Valley Animal Center,Milpitas.CA Metal Sales Manufacturing Corporation metalsales.us.com 3 4 Business License Detail for 172694 Business Activities Am I Ready to Renew? Continuing Education SIMON ROOFING AND SHEET METAL (330)629-7663 CORPORATION 3306297390 Corporation Status of Record joeb@simonroofing com Active Expires:10/23/2024 STEPHEN MANSER ALEX JAMES SIMON Nonexempt(Has Employees-Must Have Workers' JAMES JOHN SIMON Comp Coverage) ANTHONY RONALD VROSS ROCCO A AUGUSTINE 70 KARAGO AVE STEPHEN E DUKE YOUNGSTONAJ,OH 44512 Previous Names CGC1-General Contractor 1 RGC-General Contractor ADDITIONAL LICENSES/CERTIFICATES None on file EEASTi LDPR, Status Expiration Date Status Expiration Date No EEAST Associations on File No LBPR Associations on File