OFFICE COPY 5863 Lakeview Blvd.,Suite 100 Lake Oswego,OR 97035 (503)627-0100 CCB#135901 Monitor CORPORATION JAN '3 2023 PCC236 — Shell Project MY Cr 6600 Cardinal Lane Tigard, OR 97224 Fps2,02,3 - (00001 PLEASE PROVIDE COMPLETED NFPA 72 RECORD OF COMPLETION AT FINAL INSPECTION FIRE ALARM SYSTEM 5863 Lakeview Blvd.,Suite 100 Lake Oswego,OR 97035 (503)627-0100 CCB#135901 Monitor CORPORATION TABLE OF CONTENTS A. Fire Alarm System 1) Silent Knight 5208—Fire Alarm Control Panel W/Digital Communicator 3 2) System Sensor 2W-B — Photoelectric Smoke Detector 5 3) Silent Knight PS-DA—Conventional Manual Pull Stations 7 4) Gentex GB6-24—Waterflow Bell 24vdc 6" 9 5) Gentex GBBB—Weatherproof Backbox For GB6-24 11 6) Space Age SSU00689— Document Enclosure 13 7) Telguard TG7FPV—Cellular Communicator 15 0 n — ' .. — , • • —• -Al ItSILENT Model 5208 KNIGHT Fire Alarm Control Panel by Honeywell with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features • Built-in synchronization for • 10 zones, 8 Class B (Style B)and 2 appliances from AMSECO®, Class A(Style D)or Class B(Style Gentex®, Faraday, System Sensor®, B)zones, expandable to 30 zones and Wheelock® • Supervised zone expanders and I/O • Programmable date settings for modules can be mounted remotely Daylight Saving Time :- . from the main control panel • Clock source setting options for 50 _ . • Event History Buffer(150 events) Hz, 60 Hz, or internal(uses the with date/time stamp panel's internal clock) I • All zones are compatible with 2-or Specifications 4-wire detectors • 8 selectable/programmable output Operating Voltage: 24 VDC patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A circuits Total DC Load: 6 Amp • Built-in Digital Alarm Communicator Current Draw: Transmitter(DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: relays t""`" Y Height: 24.75"(62.9 cm) • Programmable smoke verification, Width: 14.5"(36.8 cm) -•-.. pre-alarm delay, cross zoning and Depth: 3-7/16"(8.73 cm) enhanced verification mode features with 5/8"protruding that can help minimize false alarms Overall Dimensions: SK-5208 • Programmable from the built-in Height: 26-3/8"(67 cm) • Plex-2 Door Option control panel touchpad, remote Width: 17-3/16"(43.66 cm) • SK-SCK Seismic Compliance Kit annunciator, or Windows®SKSS Total Depth: 4"(10.16 cm) downloading software Operating Temp: 32°to 120° F Listings and Approvals • Direct connect port for on-site (0° to 49° C) • UL Listed up/downloading with Windows® Humidity: 10-93% noncondensing • CSFM Listed SKSS downloading software • MEA approval 429-92-E Vol. XIII • Built-in walk test feature Optional Accessories • OSHPD(CA)OSP-0065-10 • Single or dual interlock water • SK-5235 LCD Remote Annunciator releasing capability • SK-5217 10 Zone Expander • Plex door option combines a dead (2 max. per system) front cabinet door with a clear • SK-5280 Status Display Module(8 window, limiting access to the panel max. per system) while providing single button • 5220 Direct Connect Module operation of the reset and silence • 5824 Serial/Parallel Printer Interface functions Module • Programmable AC trouble relay • SKSS Downloading Software • - t . 1 -. -• Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 1 Direct Connect For On-Site Programming 2 Class A (Style D) / or Class B (Style B)4 t Initiation Circuits Programmable so , ` ` ; Form C Relays .. V? 8 Class B (Style B)i— „ s a A ,�4,„ . Notification Initiation Circuits � r,� " _ _ Appliance Circuits .sHi _- - , — _ 5235 Remote El II . ,i :, _,G Annunciators (-INir"... ..A: 1 Q • SBUS Devices 21 5280. 5217, & 5824 To AC i SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA NIitkeep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#350318 Rev E subject to change without notice. For more information, contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone:(800)328-0103, Fax: (203)484-7118. For Technical support, Please call 800-446-6444. www.silentknight.com SYSTEM SENSOR Photoelectric Smoke Detectors. System Sensor i3" series smoke detectors represent • significant advancement in conventional detection. The i3 family is founded on three principles:installation 6.1 ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide •Large wire entry port ample room for neatly routing the wiring inside the base.The base •In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock"action. •Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire P detectors can generate a remote LED- •Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual-color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration. •Loop testing via EZ Walk feature •Built-in test switch Instant inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings ® L*_ MEA MSFM (� LISTED >P�ovro o I approved approved ° 18 3011446 7272-1653:152 290-01-E 2093 3180932 (6 Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor i3 Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2Wf-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5 V Maximum:35 V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 pA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 pA;4-wire:n/a Alarm Contact Ratings 2-wire:Ma;4-wire:0.5 A @ 30V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(571t)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft nominal Input Terminals 14to22AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20 mA @ 12 V,23 mA @ 24 V 4WT-B Yes 4-wire 20mA@12V,23mA@24V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter SYSTEM e.,009 System Sena,. S 3825 Ohio Avenue•St.Charles,IL 60174 N,xc,spa;ns,a ,w�tto°n,,,gewith,°t.,,ie.vm systemenm�, SENSOR ro, �1 EN 11 Phone: `Y1empr product effort/salters el Msda`a""`. A05-0318-007 MO9 X2,69 • I T '• • , • — • , '.• '• , • •' • a ItSILENT PS-DA and PS-SA KNIGHT Conventional Pull-stations J. by Honeywell Easy to Install and Operate The PS-DA/PS-SA Pull Stations are non-coded manual pull stations which provide a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The PS-DA/PS-SA pull stations includes both single-action and dual-action models equipped with key lock/ reset. It was designed to meet multiple applications with the installer and end-user in mind. Its innovative design, durable construction, and multiple mounting options make the PS- DA and PS-SA simple to install, maintain, and operate. Operation F I R The single-action pull-station is CUEGO/FIRE activated by a single pull-down of r V V / R the alarm handle. The dual-action I EMPUJEY I 0ACTIVATEO4 + PUSH IN versions require pushing in the HALE HACIAABAJO handle, then pulling the handle ' ' ' ' PULL DOWN down for activation. The PS- PUSH IN Ilr i DAPS-SA manual pull stations are PULL DOWN UL listed and meet the ADA requirement of a 5-lbs. maximum �,� pull force to activate. Operating instructions are molded into the SILENT SILENT 'is handle along with Braille text. KNIGHT KNIGHT 44 k Molded terminal numbers can be o - '- o found adjacent to the wiring termi- nals. Models: PS-DA PS-DASP PS-SA— Single action with `pigtail' Features: Specification: connections and a key lock reset. • UL Listed Dimensions: Pigtail wires are provided for con- • CSFM Listed Height: 5-1/2"(13.97 cm) nection to the Fire Alarm Control Width: 4"(10.16 cm) Panel's (FACP) initiation circuit. • Meets ADA requirements Depth: 1-7/16"(3.65 cm) • Operating instructions are mold- Operating PS-DA— Dual action model with ed into the handle along with temperature: 32°F to 120°F screw terminal connections and a Braille text. (0°C to 49°C) key lock reset. • Made of durable Lexan Electrical: Switch Contact PS-DAH — Same as PS-DA except • Available in Spanish Rating: 0.25 A @ 30 VAC with hex lock reset. • Key resettable or VDC PS-DALOB — Same as PS-DA with • Easy to Install and operate Accessories: "outdoor use" listing. Includes SB- • Single or dual action SB-I/o Surface Mount I/O backbox and sealing gasket. • Surface mount box available Back-box PS-DASP — Same as PS-DA BG-TR Trim Ring except with both English and Spanish operating instructions. PS-DA and PS-SA Conventional Pull-Stations Engineering Specification Manual Fire Alarm Stations shall be non-code, with a key-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent)with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm)or larger.` Stations shall be suitable for surface mounting on matching back-box SB-10; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm)square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA)or per national/local require- ments. Manual Stations shall be Underwriters Laboratories listed. *NOTE: The words"FIRE/FUEGO" on the PS-DASP shall appear on the front of the station in white letters, approximately 3/4" high. + + FIRE FIRE _ , 3 � � , _ , , _ t e��© oo {.ACTIVATED c i t -4:. . #T1 -i SH IN I � ' r" + PULL DOWN i SILENT ItSILL I -,q KNIGHT J .� m «.. MHaKeyvW; L 1 'g i i PS-SA Front View PS-DA Front View PS-SA Rear View PS-DA Rear View t SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are sub- P/N 350241 Rev.D ject to change without notice. For more information,contact Silent Knight 12 ©2011 Honeywell International Inc. by Honeywell Clintonville Road Northford,CT 06472-1610 Phone:(800)328-0103, Fax: (203)484-7118.www.silentknight.com GB Series GB10, GB6, & GBB Fire Alarm Bells 20 units per carton,44 pounds per carton (GB6)/50 pounds per carton (GB10) Applications The GB Series provide durable and dependable operation required for life safety alarm systems. 411111 Alarm bells are low current,high decibel notification appliances for use in fire and burglary systems or other signaling applications.The GB Series is available in 24 VDC Cco• or 120 VAC.The GB Series is available in 6"or 10"housing and listed for indoor and outdoorapplications.Bells must be used with the GBBB box for outdoor use. The GB Series is ANSI/UL 464 listed and the units are warranted for 3 years from the date of purchase. Standard Features • Available in 24 VDC or 120 VAC • Available in 6"or 10"housing • Four wire 24 VDC or 120 VAC operation • High dbA output • Mounts to a standard 4"square electrical box • ANSI/UL listed for outdoor use when used with the GBBB back box • 18 AWG wire leads • Available in red metal finish Product Listings SIGNALING l.. GB 24 VDC/GB 120 VAC Fire Alarm Bell41) Model Current Draw rag Number Part Number Voltage Housing Size (mA) dBA at10ft. LISTED GB6-24 904-1278-002 24 VDC 6" 100 mA 95 dBA • ANSUUL 464 Listed 0010-24 904-1279-002 24 VDC 10" 100 mA 96 dBA • CSFM:7135-0569:139 GB6-120 904-1280-002 120 VAC 6" 46 rnA 95 dBA • MEA#285-91-E GB10-120 904-1281-002 120 VAC 10" 46 mA 98 dBA Product Compliance • NFPA 72 Notes • Quality Management System is certified to:ISO 9001:2008 • Indoor operating temperature:32°to 120°F(0°to 49°C) '... • Outdoor operating temperature:-31°to 150°F(-35°to 65.6°C) • GBBB back box part number;901-0242-000 • GBBB back box dimensions: 4.25"(10.80 cm)square x 1.5"(3.81 cm)deep GENTEX REAM CORPORATION GB Series GB10, GB6, & GBB Fire Alarm Bells Dimensions Mini-Horn Mounting 10" DIA. GONG i----_" `•-, 4"SQUARE OUTLET BOX f - 1 if o f 6" DIA. GONG\ '- _— / . ` I - - Base �� ADAPTOR PLATE • STRIKER ADAPTOR 1 HEX-BOLT GONG t r r 15" ` Wiring Diagrams 1 3"i 4-7re" 1 ga`° D.C. BELLS (OBSERVE POLARITY) RED IN RED(OUT) i OF BASE FROM CONTROL PANELni„ TO NEXT BELL OR OR END-OF-LINE 3-29/32" PRECEDING BELL RESISTOR __ BLACK IN .4111 ,0 BLACK(OUT) 3-15t32" '4111111'/ ' A.C. BELLS RED IN Adammi,. RED(OUT) FROM CONTROL PANEL OR •4I PRECEDING BELL troll ' BLACK IN BLACK(OUT) w Architect & Engineering Specifications The fire alarm bell shall be Gentex GB Series or approved equal and shall be listed by Underwriters Laboratories(ANSI/UL)for use with fire protective signaling systems(ANSI/UL 464). The notification appliance shall produce a peak sound output of 95 dBA or greater as measured in an anechoic chamber. The fire alarm bell shall have an operating current of 100 mA or less at 24 VDC and 46 mA or less at 120 VAC. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit will mount to a double gang box or double workbox without the use of an adapter plate. The GB unit must be used with the GB88 outdoor box for outdoor applications to meet ANSI/ UL listing requirements. G ENTEX Fire Protection Products Group 110985 Chicago Drive I Zeeland,MI 49464 551-0042-04 CORPORATION gentex.com 1 Phone:616.392.7195 1 Toll-free:800.436.8391 1 Fax:616.392.4219 Important Notice:These materials have been prepared by Gentex Corporation("Gentex")for informational purposes only,are necessarily summary,and are not purported to serve as legal advice and should not be used as such,Gentex makes no representations and warranties,express or implied,that these materials are complete and accurate,up-to-date,or in compliance with all relevant local,state and federal laws,regulations and rules.The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulations and rules to particular fact patterns.Each person's activities can differently affect the obligations that exist under applicable laws,regulations or rules. Therefore,these materials should be used only for informational purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be responsible for any action or failure to act in reliance upon the information contained in this material.Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. CENTEX CORPORATION Fire Alarm Bell G B Applications The GB Series provide durable and dependable operation SERIES required for life safety alarm systems. Alarm bells are low current, high decibel notification appliances for use in fire and burglary systems or other signaling applications. The GB Series is available in 24VDC or 120VAC. The GB Series is available in 6" or 10" housing and listed forOlV ^mil indoor and outdoor applications. Bells must be used with the GBBB box for outdoor use. r, • The GB Series is UL 464 listed and the units are warranted for 3 years from the date of purchase. GB1O GB6 GBBB Standard Features Product Listings • Available in 24VDC or 120VAC SIGNALING • Available in 6"or 10"housing ID ��` • Four wire 24VDC or 120VAC operationU • High dbA output LISTED 1 • Mounts to a standard 4" square electrical box • ANSI/UL 464 • ANSI/UL listed for outdoor use when used with the GBBB back box • CSFM:7135-0569:139 • 18 AWG wire leads • MEA:#285-91-E • Available in red metal finish Product Compliance • Meets ANSI/UL 464 requirements • NFPA 72 • Quality Management System is certified to: ISO 9001:2008 GB Series Alarm Bells 24VDC or 120VAC M A MEMBER Model Part Voltage Housing Current dBA at Number Number Size Draw 10 feet GB6-24 904-1278-002 24VDC 6" 100mA 95 GB10-24 904-1279-002 24VDC 10" 100mA 96 GB6-120 904-1280-002 120VAC 6" 46mA 95 GB10-120 904-1281-002 120VAC 10" 46mA 98 Notes GBBB back box dimensions:4.25"(10.7950 cm) square x 1.5"(3.81 cm) deep GBBB part number: 901-0242-000 Operating Temperature for GB Series: Indoor Applications: 32°F to 120°F (0°C to 48.89°C) Outdoor Applications: -31°F to 150°F (-35°C to 65.56°C) z, R y G w, wt a wa Sg F %ayn . au �x e a e SERIES Dimensions Mounting 10" DIA. GONG ,---`-------. 4"SQUARE OUTLET BOX N N\ GBBB Box — --..__\ / t �\ i , IL, I I. O )) j / 6" DIA. GONG ., -� �" 0 4 3/8" , i \ ) ADAPTOR PLATE Base (27-401) • STRIKER HEX-BOLT GONG Wiring Diagrams f___ i M 'IS D.C. BELLS (OBSERVE POLARITY) r RED IN Aimi RED(OUT) OF BASE FROM CONTROL PANEL Milill TO NEXT BELL OR OR END-OF-LINE PRECEDING BELL �.�l RESISTOR BLACK IN �P BLACK (OUT) 3-29/32"i _— 3-1 2r1 A.C. BELLS RED IN ..— RED(OUT) FROM CONTROL PANEL OR ril."40 OPRECEDING BELL BLACK IN 1.idimaillifiP BLACK(OUT) NM MIIP. Architect & Engineering Specifications The audible signal shall be Gentex GB Series or approved equal and shall be listed by Underwriters Laboratories, Inc. per ANSI/UL 464.The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance shall produce a peak sound output of 95dBA or greater as measured in an anechoic chamber. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit will mount to a double gang box or double workbox without the use of an adapter plate. The GB unit must be used with the GBBB outdoor box for outdoor applications to meet UL listing requirements. 20 units per carton 44 pounds per carton GB6 50 pounds per carton GB10 Important"once. 551-0042-03 G E N T E X These ma eria s have been prepared by Centex Corporation l Centex")torhould not al purposes only,are l eemakesy summary,and are not purported to serve as legal advice and should not be used as such.Gen. CORPORATION ex makes no mpresen comp and warranties.express or implied. fl thesee mat regu are Complete re and ao curate,up-to-date,or In compliance wall all relevant egal,state and federal laws,regulations and rules.The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of Fire Protection Products Group• www.gentex.com laws,regulations and rules and Me appluation of such laws.regulations and rules to particular tad patterns. 9 Each person's activities con diaerenay affect the obligor ons that exist under applicable aws egulations or 10985 Chicago Drive •Zeeland, Michigan 49464 rules.Therefore,these materials should be used only for Intormaaonal purposes and should not be used as a substitute for seeking proleSSMnal legal advice.Genres will not be responsible for any action or failure to 616.392.7195 • 1.800.436.8391 • 61 6.392.421 9 Fax act in reliance upon the mtormaaon contained in this materialdr Genes Corporation reserves the right to make changes to the product data sheet at rhelr discretion. AC OX SRD ACE-11 System Record Documents f BY SPACE AGE ELECTRONICS Store important system documents in a secure location with a cabinet built specifically to meet the SYSTEM RECORD �' requirements of NFPA 72 7.7.2.4. � DOCUMENTS The number one goal at Space Age is to manufacture code LO • compliant solutions, and the SRD is just that. NFPA 72 7.7.2.1 states, "With every new system, a documentation cabinet shall • 1 be installed at the system control unit or other approved location at the protected premises." The SRD includes our innovative 8GB flash drive slide tab that allows the user to select a USB-C or Micro USB connector to access records electronically(See NFPA 72 7.5.6.7). owska FEATURES MoEWusp - 18 gauge cold rolled steel SPECIFICATIONS construction with red BtfCE powder coat and white The SRD System Record Documents Box shall be UL Listed, lettering constructed of 18 gauge cold rolled steel. It shall have a Idira powder coat finish.The cover shall be permanently screed with • Dimensions are 12"wide x 1" high lettering "SYSTEM RECORD DOCUMENTS" with white 13"tall and 2 1/4" deep indelible ink.The access door shall be locked with a 3/4" barrel LISTED • Stainless steel piano hinge lock and there will be a 12" stainless steel piano hinge.The SRD Two key ring hooks to hold will have a minimum of 8 gigabyte digital flash memory drive •CAL system keys with a slide tab that allows user to select USB-C or Micro USB FIRE connector for uploading and downloading information. The • Business card holder for key enclosure will supply 4 mounting holes. Inside will contacts accommodate standard 8 1/2" x 11" manuals and document • Slide tab allows user to records. A legend sheet will be attached to the door for system select USB-C or Micro USB required documentation, key contacts and system information. connector to download The enclosure shall also provide 2 key ring holders with a from 8GB digital flash location to mount standard business cards for key contact memory personnel. • DCD Computer Desk Kit (sold separately) holds CUSTOM COLORS AND BRANDING AVAILABLE enclosure door open at a 90 degree angle with a snap on cable for a convenient *' YOUR YOUR ;YOUR? YOUR YOUR working surface in the field. LOGO LOGO LOGO LOGO ` i6000_' Includes velcro strap for �' T securing your laptop. Pg. 1/2 • Ac ox DIMENSIONS 2.35 12.00 _.-10.25 __. _ ....6.00.. I I T .63 ,A i it u� SYSTEM RECORD .88 7_7:00C UMENTS 9.75 13.00 12.59 13.16 1.63 �` I .�..__._..... 11111111111IIIMIMMINIIIIIIIII111111111111111111111111111111 11 .25 _...__.11.75 ORDERING INFORMATION P/N#SSU00689 SRD System Record Documents Box - Red P/N#SS000690 SRD System Record Documents Box - Red with your custom screened logo P/N#SSU01689 SRD System Record Documents Box- Black P/N#SSU01690 SRD System Record Documents Box- Black with your custom screened logo P/N#SS000616 DCD Computer Desk Kit www.tsae.com I toll free 1.800.486.1723 I fax 508.485.4740 Ira ©Copyright 2018 Space Age Electronics,Inc.I This document subject to change without notice I LT10641 I Rev.E NFPA - noa Pg. 2i2 • A 5G ( LTE- M ) SOLE PATH T �.7 - 7FP COMMUNICATOR TELGUARD FOR COMMERCIAL FIRE THE ALARM COMMUNICATION EXPERTS k, d COMMERCIAL FIRE Feature-rich, with updated technology, the Telguard TG-7FP is all about saving time and money. It starts with a SG (LTE-M) communicator that powers off the alarm panel and costs less to purchase and install than comparable models. Add to that the savings your customers enjoy every month from replacing expensive landlines with economical cellular service. Then, top it all off with the RMR that goes to you, not the Telco. PRODUCT FEATURES f Powers directly from the fire panel's 12V/24V auxiliary power source. I- Operates on LTE-M networks, for lower power consumption and better building penetration. 1- Interfaces with fire panels using a single DACT connection for universal compatibility. 1- Backed by world-class Telguard support. 1- AT&T model available now. Verizon model coming soon. Reliable alarm signal communication is a critical element to a fire system's foundation. The TG-7FP delivers the features and functionality needed most, and it's perfect for many applications where space, access to power, and budget are considerations. Everything about installation is a breeze. Since the TG-7FP powers directly from a 12 or 24VDC alarm panel, there's no need for an electrician to install an outlet. Plus, there's no plug-in adapter or on-board battery to worry about. It all means you're in, you're out, and you're off to the next jobsite. Setting up the TG-7FP couldn't be easier. You can apply the settings you need from our website or with the Telguard Tools app - you can even do it in advance from the office. Of course, you can configure it to work with the central station of your choice. UL Listings: AT&T and Verizon Specifications Physical Details • 864 Commercial Fire Power Consumption Size(without antenna) • 1610 Central Station Standby: 18mA a:24VDC 8.25 x 5.75 x 2.0 in 40mA-a 12VDC (20.96 x 14.61 x 5.08cm) ULC Listings:AT&T Only Transmit: 110mA 'a 24VDC Shipping Weight • 5559 Commercial Fire 200mA ,a. 12VDC 2.2 lbs(1.0 kg) • S304 Commercial Burglary Compatible Formats CID, SIA, Pulse (4x2, 3x1). Compatible Accessories Certifications • ACD-12,ACD-35,ACD-50,and ACD-100: Radionics(Ile/3a7,4), DMP • California State Fire Marshal 12/35/50/mo ft of low loss, high Enclosure performance antenna cable Package Contents • Compact-size red plastic enclosure • HGDL-0i High gain directional antenna • TG-7FP universal communicator • 3 knockouts for 1/2"conduit connectors • EXDL-0: External antenna • Terminal blocks • LEDs always visible on cover • LTE antenna • Built-in tamper switch • External access to RSSI &Reset buttons !VA a CFSA verizon✓ For the most current product specifications and LIL Listings visit telguard.com/tg-7fp.In Canada,cellular data may be carried by Rogers,Bell,Telus or SaskTel. 800.229.2326 13225 Cumberland Blvd SE•Suite 300•Atlanta,GA 30339•USA I telguard.com AMETEK Cs2021 Telguard I Telguard and the Telguard Logo are registered trademarks of Telular Corporation.I Telular is a business unit of AMETEK,Inc.All Rights Reserved,