Loading...
Specifications Pun zoz3-oo/Ya q hNa�a; SPECIFICATION AND SUBMITTAL 5QA E (z� GB2 35/50 GPM Grease Interceptor for Indoor Use RECEIVED APR 2 6 2023 �` CITY OF TIGARD 23" BUILDING DIVISION _ 35.' a S g® (58cm)(89cm) ag_ � o $ go m`oo o°o7000 00000 .° o COPY sss � o0 0gosos sofa ogo oso�oo , a CDC . o eS.... 0 0 0$0 $o ____o�. , 6gv V0o00 : O�.�Q�ef� Dic� i3g" 5„ Sososo oMoe4o 0SoS3Sore - o$sgs`o s 0 0 0 0 0 o SsVsS$ (13crn) \SoS So $sa$so 0SZsos egg$$o o$ 13-3/4" `moo 0 0 0 P g`o'� /////// (35 cm) se 0 ER 2cm) � ,� I ` SCN 1 ` • 0 This unit is certified to ASME A112.14.3(Type C)and Satisfies Miami DERM 99%efficiency requirements CSA 6481.1 at two different flow rates and includes the internal flow when at least 2 units are installed in series 05 controls for both.External flow control with vent not required. SUBMITTAL Standard Options Location:indoor ❑-FO:fixed outlet diffuser Installation:above/below grade ❑FCR1(xl):>2-1/8"-12"field cut riser Flow Rates/Grease Capacities: ❑FCR1(x2):>12'- 24'field cut risers 35 GPM (22 L/s) /130.5 lbs.(59.2 kg) ❑CCI:membrane clamping collar kit(requires FCR1 riser) 50 GPM(3.2 L/s) /127.6 lbs.(57.9 kg) Solids Capacity:1.8 gal.(6.8 L) ❑PP1:pumpout port kit Liquid Capacity:20 gal.(75.7 L) El SGK2 support gusset kit Weight:49 lbs.(22.2 kg) ❑PLAIN-EA-24:2"(50 mm)plain end fitting Connections:3"(75 mm)and 4"(100 mm)plain end ❑FPT-EA-34:4"x 3"(100 mm x 75 mm)FPT fitting Cover:bolted gas/water tight polypropylene with 1,000 lb.load rating ❑FPT-EA-23:3"x 2"(75 mm x 50 mm)FPT fitting when unit is buried with FCR1 riser Approval Signature: Date: Company: Specifying Engineer: Engineering Firm: rSCHIERMODEL NUMBER: DESCRIPTION:35150 GPM Polyethylene Grease Interceptor :rRLIFETIME GUARANTEED " 1. c B2 GREASE INTERCEPTORS PART#:4065-001-05 DWG BY:B.Karrer DATE:4/10/2019 REV: ECO: 9500 Woodend Road I Edwardsville,KS 66111 I Tel:913-951-3300 I www.schierproducts.cons a Copyright 2019 Schier,All Rights Reserved Pane1of4 ASPECIAL PRECAUTIONS For Schier Grease Interceptor Installations- Failure to follow this guidance voids your warranty A WARNING! DO NOT AIR TEST UNIT OR RISER SYSTEM! Q CAUTION! Do not install this unit in any manner Doing so may result in property damage,personal injury or death. except as described in these instructions. Installation Instructions High Temperature Kitchen Water Installation instructions and additional If water is entering the interceptor at excessive temperature(over installation components are included with the instructions150°F),a drain water tempering valve(DTV)and approved backflow interceptor.Read all instructions prior inside prevention assembly must be installed.Most state and local to installation.This interceptor is plumbing codes prohibit water above 150°F being discharged into intended to be installed by a licensed the sanitary sewer.Water above 150°F will weaken or deform PVC plumber in conformance with all Schedule 40 pipe,poly drainage fixtures like interceptors and erode local codes. the coating of cast iron(leading to eventual failure). When Installing Interceptor Inside ODOR ALERT! If your dishwashing sink(s) °. Do not install air gap on outlet side discharges(into )floor drain/sink(drain),you O� l of interceptor. Ci `,` FLOW Op" must regulate the flow into ���the drain to avoid an i__----- ,:_," � overflow of water onto the M �,r kitchen floor.This can be _ psi a n I I done by installing a valve Femco or similar fiii�iie V or flow restriction caprebbcrfl CO* on restrictionw end cap the sink piping that discharges into the drain. See drawing for guidance.For detailed guidance on indirect connections,go to: webtools.schierproducts.com/Technical_Dataflndirect Connections.pdf Hydrostatic Slabs(or Pressure Slabs) When installed under a concrete slab subject to hydrostatic pressure hydrostatic slab(slab i designed to withstand Y I upward lift,usually caused by hydrostatic terpressure)interceptor cconccrrettet must be enclosed in a vault -I- watertight concrete vault SC H 1 E R MODEL NUMBER:1. DESCRIPTION:35/50 GPM Polyethylene Grease Interceptor f G B2 LIFETIME GUARANTEED rPART#:4065-001 05 DWG BY:B.Kamer DATE:4/10/2019 REV: ECO: Ct►, , GREASE INTERCEPTORS 9500 Woodend Road I Edwardsville,KS 66111 I Tel:913-951-3300 I www.schierproducts.com 6 Copyright 2019 Schier,All Rights Reserved Pena 2 of 4 A\ SPECIAL PRECAUTIONS For Schier Grease Interceptor Installations - Failure to follow this guidance voids your warranty High Water Table Installations Fully Support Base of Unit nterceptors and risers are not designed Install unit on solid,level surface in to withstand water table heightin maxord water table height contact with the entire footprint of for direct burial � r=�-- excess of the top of the unit when buried unit base;for suspended =iiiiiiiiiii�11111111111 moil. (see figure).If it is possible for this to G i, installations design trapeze to -I IIIIII- occur,install the interceptor and risers in Q ! '--11 E support the wet weight of the unit a water-tight concrete vault or backfill Interceptor Do not partially support unit or with concrete or flowable fill(wet suspend unit using metal concrete and flowable backfill should be U-channel to create a trapeze. poured in stages to avoid crushing the suspended installation interceptor).At risk areas include but are not limited to tidal surge areas, floodplains and areas that receive storm water.Great Basin"'models that are direct buried in high water table scenarios must be installed Support Inlet and Outlet Piping with an anchor kit Models GB-50,GB-75,and GB-250 use model AKl anchor kit Model GB-500 uses model AK2 anchor kit for use with For above grade installations ensure pipe supports deadmen anchors.Models GB-1000,GGI-750 and GGI-1500 use model heavy inlet and outlet piping(such as AK3 anchor kit for use with deadmen anchors cast iron or long runs)is properly I E T"TN supported or suspended during the Interceptor entire installation process to prevent Flush-to-Grade Burials connection failure or damage to Flush-to-Grade buried installations �� bulkhead fittings. (without a riser)are not recommended for heavy foot traffic areas without the use of an internal gusset support kit ::vk:{i?: :tis::ss::tis: {iE SGK2(for GB2)or SOU(for GB3). ` DO NOT • COMPACT BACKFILL _ o00 WA /1111111111111411 12 SCH I E R MODEL NUMBER: DESCRIPTION:35 f 50 GPM Polyethylene Grease Interceptor o.—] �I. �t LIFETIME GUARANTEED C*I. , GREASE INTERCEPTORS GB2 PART#:4065-001-05 DWG BY:B.Karrer DATE:4/10/2019 REV: ECO: 9500 Woodend Road I Edwardsville,KS 66111 I Tel:913-951-3300 I www.schierproducts.com ^t Copyright 2019 Schier,All Rights Reserved Pane 3 of 6 • SPECIFICATIONS Notes TOP VIEW 1. 4'FPT inlet/outlet with 3'and 4'plain end fittings. 2. Unit weight-49 lbs.(wet weight 216 lbs.) 3. Capacities- Liquid:20 gal. 35' @35 GPM-Grease:130 lbs.(17.8 gal.) - @50 GPM-Grease:127 lbs. 17.3 gal.) Outlet'A' Solids:1.8 gal. FLOW (atonal) 4. Built-in flow control. 5. For gravity drainage applications only. e> 6. Do not use for pressure applications. °o°o°o°o°a°o' °a°o°o°o°o°o° 7. Coverplacement allows full access to tank for °v °°°" ,°°°° ° 0000e oaaaa °°°°O proper maintenance. a a a a i� ski °a°°o°o° A %%C c= _ °°°o A 8. Vent not required unless per local code. o 0 0 o a o 9. Engineered inlet and outlet diffusers are °a°o°aa 1 � � p°o°o° 1T removable to inspect/clean piping. 23" -���4 _ . _" I►/�d� _ a0-0—_) MO.Integral air relief/anti-siphon. inlet-1.- °o°a°o° �� \'� °o°o°o° outlet'B' °o°Q°o° Standard) Engineer Specification Guide °°°° we •s 1+ 0000poo outlet foot oaoo I,� VI oaaa must face this °°°°° -♦ 1 00000 Schier Great Basin"grease interceptor model #GB2 °o°o°o°o°o` a°000°o°a° direction in all shall be lifetime guaranteed and made in USA of °°°°°°°°°°°e°e e°a°o°o°o°o° configurations seamless,rotationally-molded polyethylene. • Interceptor shall be furnished for above or below Outlet'c' t-- grade installation.Interceptor shall be certified to (Optional) 12-7/16'— -I ASME A112.14.3(type C)and CSA B481.1,with field cut � 'I riser system,built-in flow control and three outlet options.Interceptor flow rate shall be 35 or 50 GPM. Interceptor grease capacity shall be 130 lbs.@ 35 GPM or 127 lbs.@ 50 GPM.Cover shall provide water/gas-tight seal and have minimum 450 lbs. SECTION A-A load capacity. Ceram Performance c of 4'FPT See Note#10 Great BasinTM hydromechanical grease interceptors are inlet&outlet— ( 0 21-1/7 Cover third party performance-tested and listed by IAPMO to ASME#A11214.3 and CSA 8481.1 grease interceptor I "_ —_ _ '�='� standards and greatly exceed requirements for grease 5' -�[ltl�lii l m •�_/ of�= separation and storage.They are compliant to the L— I1 1 II Uniform Plumbing Code,the National Standard 13-3/4' 1 �ti Plumbing Code,the National Plumbing Code of Canada, I and the International Plumbing Code. I 8-34/4- 019111111M1111111111111 6-3/4'invert 11j �i ri.. I OEngineered inlet NI Static water line C�® and outlet diffuser OUTLET END VIEW Rated Grease Capacites for Units Piped in Series 23 1 No.of Units Removal Efficiency in Series 97.8% 99%• " 2 274 lbs. 180 lbs. INOTE:Flow rate for 2 GB2 units piped in series is 35 GPM only Satisfies Miami DERM 99% efficiency requirements SCH 1 E R MODEL�^NUMBER: DESCRIPTION 35/50 GPM Polyethylene Grease Interceptor "w� LIFETIME GUARANTEED L C. I. GREASE INTERCEPTORS PART#:4065-001-05 DWG BY:B.Kamer DATE:4/10/2019 REV: ECO: 9500 Woodend Road I Edwardsville,KS 66111 I Tel:913-951-3300 I www.schierproducts.com c Copyright 2019 Schier,All Rights Reserved Pane 4 of 6