Loading...
Report (2) Oregon Residential Specialty Code M1505.4 Balanced Mechanical Whole-House Ventilation System Installed msrzoz,--pogo/ Permit No.: 1177/20 r - Jurisdiction: l RR o Site Address: 1607 5 , CgloRAP0 CA/ Subdivision/Lot#: 5wil, n'UC( -6 ,06 e and/or f� Map and Tax Lot#: l3io 7/a.p 1 By my signature below, I certify that the Mechanical Whole-House Ventilation System has been installed at the address listed above per the requirements of the Oregon Residential Specialty Code and Section M1505.4. Q /S Signature: I Date: 0 -21? ^T J Own General Contractor/Authorized Agent Print Name: R oh G o&i4" I:\Building\Fonns\RES-HighEffi c iencyLightingAcknowledgement_022018 Oregon Residential Specialty Code R408.1 MOISTURE BARRIER ACKNOWLEDGEMENT FORM I, R0h KPctin/ , am the general contractor or the owner-builder at the following address: Site Address: f� )7 Sw COLORq.00 L '/ City: TI G A R D Permit#: in 9T702 —Op ZOc, Subdivision/Lot#: SOV I h K i v"r Yricice and/or Map and Tax Lot#: /2i 0 2 3 / g 0 To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R408.1 Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per Requirement in ORSC Section 408.1 and have taken the following steps to meet this code requirement: n The ground surface of the under-floor space is covered by a Class I vapor retarder or other approved materials, with Joints lapped 12 inches at seams and I V I Extending up the foundation walls 12 inches. Signature: , 'Al/ Date: g 2 3 eral Contractor or Owner-Builder 1:1Building\Form\RES-Mo istureBarrierAcknowledgement_0220I8 Oregon Residential Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Permit No.: !M5r20 22-002 09 Jurisdiction: 9 p,n Site Address: 14,637 cog) r i WO L/V Subdivision/Lot#: 500TA River Tel'c/c and/or Map and Tax Lot#: ( L0 0 l By my signature below, I certify that all of the permanently installed lighting fixtures in the above mentioned building contain high-efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement. (Oregon Residential Specialty Code N1107.2)1 Signature: Date: F--/S O r/General Contractor/Authorized Agent Print Name: R 0I 1170e614, ORSC Section N1107.2.High-efficacy lamps. All permanently installed lighting fixtures shall contain high- efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement. The building official shall be notified in writing at the final inspection that the permanently installed lighting fixtures have met this requirement. Exception: Two permanently installed lighting fixtures are not required to have high-efficacy lamps. 1.1Building\Forms\RES-H ighEfficiencyL ightingAcknowledgement_022018 Oregon Residential Specialty Code R318.2 MOISTURE CONTENT ACKNOWLEDGEMENT FORM Rob 1-Coe WI , am the general contractor or the owner-builder at the following address: Site Address: (40)7 Sw coCoRtainn Le/ City: rUA Rn Permit#: /h57"io — 0020q Subdivision/Lot#: 500/LA R;vet 1ef(/:"d and/or Map and Tax Lot#: (3L0 23 / g� ,c i To conform with the 2017 Oregon Residential Specialty Code(ORSC), Section R318.2 and OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference]. R318.2 Moisture Content: Prior to the installation of interior finishes,the building official shall be notified in writing by the general contractor that all moisture-sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. Signature: Date: ^ CC--2 3 Gener Contractor or Owner-Builder 1.1Bui Id ing\Fonn\RES-Mo istureContentAcknowledgement_022018 (flip 9,3/ 491 gt'0I Blower Door Test - MsA-20 ° oci MEM ■ Moffet Energy Modeling Af f I d av i t ccB#223372 916-342-0742 Tyler@moffetco.com Site Details Builder Taylor Morrison Subdivision South River Terrace Lot 601 Street 16637 SE Colorado Ln C City/State/Zip Tigard, OR 97224 Conditioned Floor Area 2026 square feet Conditioned Volume 18362 cubic feet Source Plans Test Conditions Equipment Minneapolis Blower Door and DG 700 Manometer Ring A Weather Clear Test Results Infiltration 1520.00 CFM @ 50 Pa ACH (CFM * 60/Volume) 4.97 @ 50 Pa I certify that these building leakage rates are accurate and determined using standard BPI testing protocols. Company Name: Moffet Energy Modeling Technician: Tyler Moffet Technician Signature: 7 1-,G //R/ Date: 7/31/2023