Report • •
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: 5rZoZZ.— O 3(p ( Jurisdiction: n1_7
Site Address: 9 Sfy3 &A)
Subdivision/Lot#: 1C-1.Jc✓ l�C rr � e Sc2 / 9
and/or
Map and Tax Lot#:
By my signature below, I certify that all of the permanently installed lighting fixtures in the
above mentioned building contain high-efficacy lamps. Screw-in compact fluorescent and LED
lamps comply with this requirement. (Oregon Residential Specialty Code N1107.2)1
Signature: D Date: (// Z(e/o73
Owner/Genergl Contra /Authorized Agent
Print Name: r � 1'l Y u S-e
ORSC Section N1107.2.High-efficacy lamps. All permanently installed lighting fixtures shall contain high-
efficacy lamps. Screw-in compact fluorescent and LED lamps comply with this requirement.
The building official shall be notified in writing at the final inspection that the permanently installed lighting fixtures
have met this requirement.
Exception: Two permanently installed lighting fixtures are not required to have high-efficacy lamps.
I: ui Iding\Forms\RE S-HighEffic iencyL ightingAcknowledgement_022018
Oregon Residential Specialty Code R408.1
MOISTURE
rI BARRIER ACKNOWLEDGEMENT FORM
I, 1 7 j J UJtekf 7 /]OkLt5 , am the general contractor or the owner-builder
at the following address:
Site Address: 5.1( S(.) Cool("1-t-/
City:
lIbc4
Permit#: V1451— Zo7L - O0314. 0
Subdivision/Lot#: J�./
and/or
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
he ground surface of the under-floor space is covered by a Class I vapor retarder or
��other approved materials, with
L_I Joints lapped 12 inches at seams and
Extending up the foundation walls 12 inches.
SignatureDate: 6- /Zee
General CoCo tractor Owner-Builder
1:1B uild ing\Form\RES-MoistureBarrierAcknowledgement_022018
•
Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, Tod / Oda, 440.d,LS, am the general contractor or the owner-builder
at the following address:
Site Address: ( 57143 Sw Coo)Wm1
City:
Permit#: 5.r ? ZZ _ GO 36,
Subdivision/Lot#: S—�
l C✓ 1 fru-e-c C reSS �"
and/or
Map and Tax Lot#:
To conform with the 2017 Oregon Residential Specialty Code (ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes,the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: Date: /z /zos3
General Contr for or caner-Builder
1:\Building\Fonn\RES-MoistureContentAcknowledgement_022018
%,
Form 640E 2017 -I Ne
Completion Certification—Site Inspection E n e rgyTr V St
New Homes Program—Single Family
of Oregon
To be completed by Verifier
CLEAResutt to a Program Management Contractor for Energy Trust of Oregon,Inc.
Payment Information
Incentive Payee Company Name: !David Weekly Homes ,Is Nis payment redirected? INo
Builder or Company: David Weekly Homes Redirect to Name:
Verifier Payee Company Name: Performance Insulation and Energy Redirect Payee Corn
Affordable Housing No
Solar Ready Builder Incentive: Yes !Solar ReadyVerifier IncelYes
Site Infonrwtion
Deveioprnent: RIVER TERRACE CROSSING 'Lot =JS Axis ID: IREM/Ratee tD:
Address: 15143 SW COOLWATER LN
Street Line 2 Multi-Femiy No City: TIGARD Slate: OREGOII Zip: 97224
Total conditioned area(sq.it): 2.569 House Volume: I 23,474 Housing Type: Detached single family
Member of Stories: 12 Number of Bedrooms: 4 Foundation Type: Crawlspace
Electric Provider: Portland General Electric Gas Provider: NW Natural Gas
Solar installed None Solar Installer Name/Company-
Blue shaded fields are required For EPS sheet
Verification Type Actual Model Equipment Detegs 8 Notes
Slab Perimeter Insulation R- Slab Under Insulation R-
InsuWtlon Framed Floor R- 30.0 Secondary Framed Floor R-
Above Grade Well Insulation R- 23.0 Below Grade Wall Insulation R-
Flat Ceiling Insulation R- 49.0 Vaulted Ceiling Insulation R-
Windows Windows U- 0.3 SHGC:l0.3 Total window area: I
Cooling Air Conditioning CFFR: 0 Model it:
Primary Heating System Details AFUE: 95.5 Brand Bryant
Type: Gas Furnace HSPF: Model 0: 9158842060E17A-A
Primary Heat Heating Fuel: Gas SEER:
Source Comment: COP: _
location: Conditioned A Outdoor Unit(for heat pumps)
ECM: No Model 0: '
AHRI Certificate:5584119 0 M Systems II
Callon: -I Brand: Rheem
Water Heater Type Heat Pump SF: 1.82 Model 0: PRO H65 T2 RH310UM
Water Heating Fuel Electric Location: !Garage or ope AHRI Certificate:NA
Ducts and Dud Location 'Pertlal %ducts Inside: 111111111111Duct Leakage(CFM) 50Pe: 1186
Tasting ra ,..
Infiltration Air Changes per Hour(ACH)@ 50Pa: 2.6
VentilationVentilation Type HRV/ERV Model:
Supply Side-Air Cyder Airflow measured or why untestabie7 I Roof Termination
Appliances
Refrigerator kWhlyr Model:
ENERGY STAR Dnwasher k Wh/yr Model: KDTM404KPS1
Percent High Efficacy Interior Lighting(%) Thermostat
Showerheed 1.5 GPH I Showerwand 1.5 GPH I Showerhead 1.6 GPH ' IShowemead 1.75 GPH I
Notes: