Permit Support Document (38) Branden Taggart From: Branden Taggart Sent: Wednesday, August 9, 2023 5:06 PM To: 'Ed & Cathy Toews' Subject: RE: FW: Water Meter Fixture Unit Worksheet for ADU: MST2020-00338 - 12185 SW Plantation Terrace _ Attachments: FY-2022-23-Rates-Charges-2.pdf Ed, Per our phone conversation, I confirmed that the sewer fees are correct. In your case the sewer fee calculation are based upon the Residential II Rate Method found on page 19 of the attached Clean Water Services Rates and Charges. According to the approved Water Meter Fixture Unit Worksheet, a 1" water meter is calculated to be served, and so the fees are based upon the number of total bedrooms in the dwelling. Since the total number of bedrooms went from (5)to (4) with the new ADU, we will assess (1) DUE for(4) bedrooms at a rate of$5,800.00 (based upon the 2020 received date) plus the $35.00 inspection fee for a total of$5,835.00. I have included excerpts below regarding the fee calculation: 3. Residential II Rate Method a. This method will apply to five major categories: 1) Residential dwellings, including any ancillary dwelling units located on the same lot,that are served (or calculated to be serred)by larger than a three-quarter- inch water meter and service. 2) Motel and hotel units without individual kitchens. 3) Dormitories. 4) Bed and breakfast facilities and other commercial lodging facilities, 5) Recreational vehicle parks. t CALCULATION: Residential dwelling,dormitories, hotels,motels,commercial lodging facilities: 1 DUE for the first five bedrooms plus one half DUE for each additional bedroom. le Recreational Vehicle Parks: 1 DUE= 2 recreational vehicle spaces with sewer hookups Once the sewer fees are paid online, I will email you a copy of the Sewer permit and will remove the hold from the ADU permit MST2020-00338. Also, it appears that the existing dwelling already has (4) bathrooms, so I presume there is currently a 4" sanitary sewer line. If you are not certain of your sanitary sewer line size, I recommend that you confirm the size, as upsizing your sewer line is costly. Please let me know if you have additional questions. Thank you, Branden Taggart • City of Tigard it Senior Permit Technician Community Development TIGARD 13125 SW Hall Blvd Tigard, OR 97223 (503)718-2449 brandent@tigard-or.gov From: Branden Taggart Sent: Wednesday, August 2, 2023 2:57 PM To: Ed &Cathy Toews<UsTwo@thetoews.com> Subject: RE: FW: Water Meter Fixture Unit Worksheet for ADU: MST2020-00338- 12185 SW Plantation Terrace Ed, You are welcome. I have added the Owner Responsibility form to the permit. Have a good evening. Thanks, 2 Branden Taggart IICity of Tigard Senior Permit Technician Community Development T IGARD 13125 SW Hall Blvd Tigard, OR 97223 (503)718-2449 brandent@tgard-or.gov From: Ed &Cathy Toews<UsTwo@thetoews.com> Sent: Friday, July 28, 2023 1:51 PM To: Branden Taggart<brandent@tigard-or.gov> Subject: Re: FW: Water Meter Fixture Unit Worksheet for ADU: MST2020-00338 - 12185 SW Plantation Terrace Hi Branden, Thank you so much for all your help making this happen. We really appreciate your efficiency and understanding. We look forward to getting this work completed. Please see a copy of the Owner Responsibility form submitted with the project application attached. Thanks again, ed On Wed,Jul 26, 2023 at 4:52 PM Branden Taggart<brandent@tigard-or.gov>wrote: Ed and Jordan, The ADU permit is ready to issue now. The balance due is$6,370.52, and I have attached an invoice above for reference. The permit fees can be paid online through our website https://aca.accela.com/TIGARD/Default.aspx by searching for the permit record number MST2020-00338, or in person between the hours of 8:00 a.m. and 6:00 p.m., Monday through Thursday. We are closed on Fridays. If paid online, please have someone pick up the permit and the approved site copy set of plans. Additionally,a signed Owner Responsibility Form will need to be submitted before this permit can be issued. Thank you, 3 Branden Taggart City of Tigard M Senior Permit Technician - Community Development I Yt,AKI) 13125 SW Hall Blvd Tigard, OR 97223 (503)718-2449 hrandentitigard-or.gov From: Branden Taggart Sent:Thursday,July 20, 2023 6:55 PM To: Ed &Cathy Toews<UsTwo@thetoews.com> Cc:ADU@thetoews.com;Allyson Armstrong<Al�sonAtJgard-or.gov> Subject: RE: Water Meter Fixture Unit Worksheet for ADU: MST2020-00338- 12185 SW Plantation Terrace Ed, Thank you for your submittal. I have routed the revised plans to Allyson for plan review. Our Utility Billing Department approved the Water Meter Fixture Unit Worksheet already, and their supervisor confirmed that the SDC fees for a %" water meter were originally paid;therefore,you will need to pay the difference in fees to upsize to the 1" water meter. Have a good weekend. Thank you, Branden Taggart , City of Tigard s Senior Permit Technician Community Development r ft.ARt 13125 SW Hall Blvd Tigard,OR 97223 (503)718-2449 brandent@tgard-or.gov From: Ed &Cathy Toews<UsTwo@thetoews.com> Sent:Thursday,July 20, 2023 11:27 AM To: Branden Taggart<brandent@tigard-or.gov> 4 Cc: ADU@thetoews.com; Allyson Armstrong<AllysonA@tigard-or.gov> Subject: Re: Water Meter Fixture Unit Worksheet for ADU: MST2020-00338 - 12185 SW Plantation Terrace You don't often get email from ustwo@thetoews.com. Learn why this is important Hi Brandon, Thanks so much for looking into this and I am sorry I missed your call this morning. We have attached the worksheet supplied earlier. As you can see, the current renovations are not causing the jump from 3/4" to 1". The house required the 1" meter from the beginning. Does this make any difference to the attorney's decision? BTW, we spoke with Ms. Armstrong and, apparently, the documentation for the original building application has been purged from your files. We will be submitting everything again, probably tomorrow. Thanks again for working on this. ed On Thu,Jul 20, 2023 at 10:04 AM Branden Taggart<brandent@tigard-or.gov>wrote: Hello Jordan, I spoke with Ed Toews recently who inquired about the status of your ADU permit submittal and also the water meter. I'm not sure of your relation to Ed, but I wanted to let you know of the water meter situation if you have not been informed. Since the existing water meter for your property is a 5/8" meter, our City Attorney mentioned that the SDC fees would not need to be repaid for the upsize to a %" meter; however, since the water meter needs to be upsized from a 3" to a 1" meter for the ADU, the difference in fees of$13,494.00 will need to be paid. I could not locate a completed Water Meter Fixture Worksheet with your 2020 submittal, so we will need to receive the completed worksheet attached above for Utility Billing approval before we can issue the Building permit. You are welcome to email the completed worksheet back to me,and I will forward it to our Utility Billing Department. Thank you, 5 Branden Taggart From: Allyson Armstrong Sent: Monday,July 31, 2023 8:05 AM To: Branden Taggart Subject: FW: Basement 1/2 bath - Towes ADU / MST2020-00338 & MST2021-00350 Attachments: image001.jpg Branden, Here is the response I got back form Ed Towes regarding the From: Ed Toews<Ed@thetoews.com> Sent: Friday,July 28, 2023 9:46 AM To:Allyson Armstrong<AllysonA@tigard-or.gov> Subject: Re: Basement 1/2 bath Hi Allyson, Sorry for the delay in responding. We were working with another jurisdiction yesterday. Yes, the bathroom information is correct.We added the two-piece to the non-ADU part of the basement because the existing basement bathroom will now be part of the ADU. The 2020-000350 bathroom work is upstairs. Thanks for checking, ed On Thu,Jul 27, 2023, 10:14 AM Allyson Armstrong <AllysonA@tigard-or.gov>wrote: Ed, Please verify the following information. We are just trying the make sure all work is getting captured and on the correct permits. This email is only regarding the bathroom work. MST2020-00338 1 Toilet 1 bath lavatory MST2021-00350 1 bath lavatory 1 toilet 1 tub / shower 1 Branden Taggart From: Branden Taggart Sent: Wednesday, July 26, 2023 4:52 PM To: Ed &Cathy Toews; ADU@thetoews.com Subject: FW:Water Meter Fixture Unit Worksheet for ADU: MST2020-00338 - 12185 SW Plantation Terrace Attachments: ADU Invoice.pdf; Owner Responsibility Form.pdf Ed and Jordan, The ADU permit is ready to issue now. The balance due is$6,370.52, and I have attached an invoice above for reference. The permit fees can be paid online through our website https://aca.accela.com/TIGARD/Default.aspx by searching for the permit record number MST2020-00338,or in person between the hours of 8:00 a.m.and 6:00 p.m., Monday through Thursday. We are closed on Fridays. If paid online, please have someone pick up the permit and the approved site copy set of plans. Additionally,a signed Owner Responsibility Form will need to be submitted before this permit can be issued. Thank you, Branden Taggart ■ City of Tigard Senior Permit Technician Community Development TiC.lt0 13125 SW Hall Blvd Tigard,OR 97223 (503)718-2449 brandent@tigard-or.gov From: Branden Taggart Sent:Thursday,July 20, 2023 6:55 PM To: Ed & Cathy Toews<UsTwo@thetoews.com> Cc:ADU@thetoews.com;Allyson Armstrong<AllysonA@tigard-or.gov> Subject: RE:Water Meter Fixture Unit Worksheet for ADU: MST2020-00338- 12185 SW Plantation Terrace Ed, Thank you for your submittal. I have routed the revised plans to Allyson for plan review. Our Utility Billing Department approved the Water Meter Fixture Unit Worksheet already, and their supervisor confirmed that the SDC fees for a %" water meter were originally paid;therefore,you will need to pay the difference in fees to upsize to the 1" water meter. Have a good weekend. Thank you, 1 Ir Branden Taggart el City of Tigard i1 xi:_,:. Senior Permit Technician Community Development TIGARD 13125 SW Hall Blvd Tigard, OR 97223 (503)718-2449 brandent@tigard-or.gov From: Ed & Cathy Toews<UsTwo@thetoews.com> Sent:Thursday,July 20, 2023 11:27 AM To: Branden Taggart<brandent@tigard-or.gov> Cc:ADU@thetoews.com; Allyson Armstrong<AllysonA@tigard-or.gov> Subject: Re: Water Meter Fixture Unit Worksheet for ADU: MST2020-00338 - 12185 SW Plantation Terrace You don't often get email from ustwo@thetoews.com.Learn why this is important Hi Brandon, Thanks so much for looking into this and I am sorry I missed your call this morning. We have attached the worksheet supplied earlier. As you can see, the current renovations are not causing the jump from 3/4" to 1". The house required the 1" meter from the beginning. Does this make any difference to the attorney's decision? BTW, we spoke with Ms. Armstrong and, apparently, the documentation for the original building application has been purged from your files. We will be submitting everything again, probably tomorrow. Thanks again for working on this. ed On Thu,Jul 20, 2023 at 10:04 AM Branden Taggart<brandent@tigard-or.gov>wrote: Hello Jordan, I spoke with Ed Toews recently who inquired about the status of your ADU permit submittal and also the water meter. I'm not sure of your relation to Ed, but I wanted to let you know of the water meter situation if you have not been informed. Since the existing water meter for your property is a 5/8" meter, our City Attorney mentioned that the SDC fees would not need to be repaid for the upsize to a '/" meter; however, since the water meter needs to be upsized from a %" to a 1" meter for the ADU,the difference in fees of$13,494.00 will need to be paid. I could not locate a completed Water Meter Fixture Worksheet with your 2020 submittal, so we will need to receive the completed worksheet attached above for Utility Billing approval before we can issue the Building permit. You are welcome to email the completed worksheet back to me, and I will forward it to our Utility Billing Department. Thank you, 2 1 • Branden Taggart From: Branden Taggart Sent: Thursday,July 20, 2023 6:10 PM To: Darren Black Cc: Karen Abdill Subject: RE:ADU Permit for Ed Toews: MST2020-00338 - 12185 SW Plantation Terrace Attachments: Water Meter Worksheet for 12185 Plantation Terrace.pdf Hey Darren, I have attached the worksheet for approval. Ed mentioned that a 1" water meter should have originally been installed instead of the 5/8" meter. I relayed the message that he would only have to pay the difference for the upsize from'/" meter to a 1" meter, but he insisted that a 1" meter should have originally been installed. Thanks, Branden Taggart eg City of Tigard Senior Permit Technician Community Development Tte l RI) 13125 SW Hall Blvd Tigard,OR 97223 (503)718-2449 brandent@tigard-or.gov From: Branden Taggart Sent:Tuesday,July 18, 2023 8:17 AM To: Darren Black<darren.black@tigard-or.gov> Cc: Karen Abdill<karen.abdill@tigard-or.gov> Subject: RE: ADU Permit for Ed Toews: MST2020-00338- 12185 SW Plantation Terrace Thanks, Darren. I will contact Ed for the worksheet. Thank you, Branden Taggart III City of Tigard Senior Permit Technician Community Development TlCAR 13125 SW Halt Blvd Tigard,OR 97223 (503)718-2444 b randent@tigard-o r,gov From: Darren Black<darren.black@tigard-or.gov> Sent:Tuesday,July 18, 2023 8:02 AM 1 " To: Branden Taggart<brandent@tigard-or.gov> Cc: Karen Abdill <karen.abdill@tigard-or.gov> Subject: RE:ADU Permit for Ed Toews: MST2020-00338 - 12185 SW Plantation Terrace Hey Branden, I heard back from Shelby a little while ago and she advised Mr.Toews would not have to repay the SDC fees for the upsize of his meter, rather just pay the difference between the two meters. For example if he is upsizing from a %" to a 1" he would need to pay$13,494.00. If I can get the water meter fixture sheet I can review and approve to move him along the way. Thank you, Darren Black I Utility Billing Supervisor ' City of Tigard I Utility Billing Direct: 503.718.2574 From: Branden Taggart Tigard 13125 SW Hall Boulevard,Tigard OR 97223 I tigard-or.gov <brandent@tigard-or.gov> Sent: Monday,July 17, 2023 2:23 PM To: Darren Black <da rren.black@tiga rd-or.gov> Cc: Karen Abdill<karen.abdill@tigard-or.gov> Subject:ADU Permit for Ed Toews: MST2020-00338- 12185 SW Plantation Terrace Hey Darren, We spoke with Ed Toews regarding his ADU permit submittal at 12185 SW Plantation Terrace. He mentioned that you are currently working with Shelby Rihala regarding the water meter-situation. Ed inquired about being able to proceed with the"Plumbing permit" before a decision is made with the water meter, but I mentioned that we would normally require water meter approval prior to permit issuance, and I would need to check with you. The plumbing scope of work was included with the submittal for permit MST2020-00338, and we are currently waiting on fire wall revisions to proceed with issuing the permit, which are likely to be received soon. So, it sounds like the permit can be made ready to issue quickly once the revisions are received. I did not see a Water Meter Fixture Unit Worksheet with Ed's submittal. Do you need a completed worksheet to approve? Thank you, Branden Taggart IIIy ■ City of Tigard Senior Permit Technician Community Development ment TlcAttTa 13125 SW Hall Blvd Tigard, OR 97223 [5031 718-2449 brandent@tigard-or,gov DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail 2 Branden Taggart From: Branden Taggart Sent: Thursday, July 20, 2023 10:04 AM To: adu@thetoews.com Subject: Water Meter Fixture Unit Worksheet for ADU: MST2020-00338 - 12185 SW Plantation Terrace Attachments: W aterMeters_070121_Add_Detail.pdf Hello Jordan, I spoke with Ed Toews recently who inquired about the status of your ADU permit submittal and also the water meter. I'm not sure of your relation to Ed, but I wanted to let you know of the water meter situation if you have not been informed. Since the existing water meter for your property is a 5/8" meter, our City Attorney mentioned that the SDC fees would not need to be repaid for the upsize to a %" meter; however, since the water meter needs to be upsized from a %" to a 1" meter for the ADU,the difference in fees of$13,494.00 will need to be paid. I could not locate a completed Water Meter Fixture Worksheet with your 2020 submittal, so we will need to receive the completed worksheet attached above for Utility Billing approval before we can issue the Building permit. You are welcome to email the completed worksheet back to me, and I will forward it to our Utility Billing Department. Thank you, Branden Taggart ■ City of Tigard t..,. Senior Permit Technician Community Development TICAR#3 13125 SW Flail Blvd Tigard,OR 97223 (503)718-2449 brandent@tigard-or.gov 1 Branden Taggart From: Branden Taggart Sent: Tuesday, July 18, 2023 8:17 AM To: Darren Black Cc: Karen Abdill Subject: RE:ADU Permit for Ed Toews: MST2020-00338 - 12185 SW Plantation Terrace Thanks, Darren. I will contact Ed for the worksheet. Thank you, Branden Taggart INCity of Tigard $ Senior Permit Technician TICAD Community Development 13125 SW Hall Blvd Tigard,OR 97223 (503]718-2449 brandent@tigard-or.gov From: Darren Black<darren.black@tigard-or.gov> Sent:Tuesday,July 18, 2023 8:02 AM To: Branden Taggart<brandent@tigard-or.gov> Cc: Karen Abdill <karen.abdill@tigard-or.gov> Subject: RE:ADU Permit for Ed Toews: MST2020-00338- 12185 SW Plantation Terrace Hey Branden, I heard back from Shelby a little while ago and she advised Mr.Toews would not have to repay the SDC fees for the upsize of his meter, rather just pay the difference between the two meters. For example if he is upsizing from a %"to a 1" he would need to pay$13,494.00. If I can get the water meter fixture sheet I can review and approve to move him along the way. Thank you, Darren Black I Utility Billing Supervisor City of Tigard I Utility Billing Direct: 503.718.2574 From: Branden Taggart CITY OF T g a rd 13125 SW Hall Boulevard, Tigard OR 97223 I tigard-or.gov <brandent@tigard-or.gov> Sent: Monday,July 17, 2023 2:23 PM To: Darren Black <darren.black@tigard-or.gov> Cc: Karen Abdill <karen.abdill@tigard-or.gov> Subject: ADU Permit for Ed Toews: MST2020-00338- 12185 SW Plantation Terrace Hey Darren, 1 We spoke with Ed Toews regarding his ADU permit submittal at 12185 SW Plantation Terrace. He mentioned that you are currently working with Shelby Rihala regarding the water meter situation. Ed inquired about being able to proceed with the"Plumbing permit" before a decision is made with the water meter, but I mentioned that we would normally require water meter approval prior to permit issuance, and I would need to check with you. The plumbing scope of work was included with the submittal for permit MST2020-00338, and we are currently waiting on fire wall revisions to proceed with issuing the permit,which are likely to be received soon. So, it sounds like the permit can be made ready to issue quickly once the revisions are received. I did not see a Water Meter Fixture Unit Worksheet with Ed's submittal. Do you need a completed worksheet to approve? Thank you, Branden Taggart 4 City of Tigard Senior Permit Technician Community Development Ti ARI) 13125 SW Hall Blvd Tigard, OR 97223 (503)718-2449 bra ndent@tigard-or.gov DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained by the City of Tigard in compliance with the Oregon Administrative Rules"City General Records Retention Schedule." 2 Dianna Ornelas From: ed@thetoews.com Sent: Monday, December 14, 2020 7:08 PM To: #Building Permit Technicians Cc: Jordan; UB Online; Mai Quach Subject: RE:Toews ADU - 12185 SW Plantation Terrace Categories: Dianna Warning!This message was sent from outside your organization and we are unable to verify the sender. Hi Dianna, Thanks very much for thinking of us and minimizing our risk. As with others in your department,your service is excellent and encourages following the process. I am not sure whether or not you know, but Ms. Smith is aware of the documentation we dropped off thereon Thursday. Here is what we know about the meter: 1. The changes we are making should not have triggered a meter size increase. However, 2. The existing meter is registered as 5/8" and the house, as it was when we purchased the property, requires a 1" meter—two sizes larger. 3. A technician came to site very promptly and confirmed the physical meter is 5/8" and this is not just a documentation error 4. The meter was installed new in 2016 when the original meter for this house was re-assigned to one of the new houses added to the property.The new meter should have been sized appropriately at the time 5. The technician who came to site informed us that the utilities department will be contacting us once they determine what is required to correct the existing issue 6. We have not heard anything from the utilities department (copied on emails mentioning this issue) so assume they have discovered some complications related to this issue or are seeking an option to help us out with this We are also waiting to have the SDC exemption covenant recorded with the county. In our new world, getting the missing signature requires a few days of mailing documents back and forth and we are in the process of getting this completed. We are hoping both recording the covenant and resolving the water meter issue occur fairly promptly and are confident the responsible parties are doing the best they can. If you have any other advice, we are all ears, Thanks again for taking care of us, ed Ed Toews I +1.317.863.9776 (h); +52(1)668.187.85.22 (m); +1.503.702.9503(c) From:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Sent: December 14, 2020 6:19 PM To: ed@thetoews.com Cc: 'Jordan' <Jordan@TheToews.com>; UB Online <UBOnlinepay@tigard-or.gov>; Lina Smith <LinaCS@tigard-or.gov> Subject: RE:Toews ADU - 12185 SW Plantation Terrace Importance: High Hi Ed, 1 Dianna Ornelas From: #Building Permit Technicians Sent: Monday, December 14, 2020 6:19 PM To: ed@thetoews.com Cc: 'Jordan'; UB Online; Lina Smith Subject: RE:Toews ADU - 12185 SW Plantation Terrace Importance: High Hi Ed, I have received the permit application packet and will route to Lina for review, however I need to know about the water meter. Did you actually submit a water meter worksheet to UB and get their approval? My apologies as I cannot find where this item was completed and I need to know what the outcome of that review was. Does the meter need to be upsized? You need this resolved before we route the plans for review because the plan review fee is non-refundable if you decide to not go through with this project because of the additional water meter costs. Thank you. Dianna L. Ornelas Building Division Services Supervisor City of Tigard I Community Development 13125 SW Hall Blvd I Tigard, OR 97223 503-718-2430 Direct 1503-718-2439 Permits From: ed@thetoews.com <ed@thetoews.com> Sent:Thursday, December 10, 2020 6:15 PM To: Lina Smith <LinaCS@tigard-or.gov> Cc: 'Jordan' <Jordan@TheToews.com>;#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Subject: RE:Toews ADU - 12185 SW Plantation Terrace Warning!This message was sent from outside your organization and we are unable to verify the sender. Thanks Lina. Dropped the plans off today in hopes of getting an early start next week. ed Ed Toews I +1.317.863.9776 (h); +52(1)668.187.85.22 (m); +1.503.702.9503(c) From: Lina Smith <LinaCS@tigard-or.gov> Sent: December 10, 2020 5:07 PM To: ed@thetoews.com Cc: 'Jordan' <Jordan@TheToews.com>;#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov>; Mai Quach <maiq@tigard-or.gov>; UB Online<UBOnlinepay@ tigard-or.gov> Subject: RE:Toews ADU - 12185 SW Plantation Terrace Thanks Ed. I can get started on the Planning/Zoning review while we wait for the items you listed in your e-mail.Just FYI our office is closed on Fridays. 1 • Have a good weekend, Lina Lina Smith Assistant Planner City of Tigard I Community Development 13125 SW Hall Blvd.Tigard,OR 97223 E-mail: LinaCS(a tgard-or.gov From: ed@thetoews.com <ed@thetoews.com> Sent:Thursday, December 10, 2020 4:55 PM To: Lina Smith <LinaCS@tigard-or.gov> Cc: 'Jordan'<Jordan@TheToews.com>;#Building Permit Technicians<TigardBuildingPermits@tgard-or.gov>; Mai Quach <maiq@tgard-or.gov>; UB Online<UBOnlinepay@tigard-or.gov> Subject: RE:Toews ADU - 12185 SW Plantation Terrace Hi Lina, This afternoon, we dropped off the plans, calculations, and diagrams, but not the exemption covenant or the water meter confirmation. There are a couple of issues: 1. Washington County would not record the SDC exemption covenant because the document was missing the signature of the interim city manager. We are working with Ms. Quach to get this resolved. 2. Utility billing has confirmed our water meter is only 5/8" and is now determining our path forward.The ADU changes we are making should not have triggered a meter change but the existing meter was undersized for the existing house water load. We will bring the remaining documentation over once the issues are resolved. Please let us know if there is anything else needed. Thanks for your help, ed Ed Toews I +1.317.863.9776 (h); +52(1)668.187.85.22 (m); +1.503.702.9503(c) From: Lina Smith<LinaCS@tigard-or.gov> Sent: November 24, 2020 11:17 AM To: ed@thetoews.com Cc: 'Jordan' <Jordan@TheToews.com>;#Building Permit Technicians<TigardBuildingPermits@tgard-or.gov>;Allyson Armstrong<AllysonA@tgard-or.gov>; Mai Quach <maiqPtigard-or.gov> Subject:Toews ADU - 12185 SW Plantation Terrace Hi Ed, Sorry for the delay in getting back to you. I reviewed your revised floor plans with my supervisor, and confirmed that the ADU is under 1,000 square feet in size.Just FYI we measure floor area from the outside of the exterior walls; regardless, the ADU is still under 1,000 square feet in size. We'll need to wait until Mai's finished with your SDC exemption paperwork before Building can start processing your building permit application. In the meantime, please work on the following items: • Please revise your building permit applications with the 12185 address for the ADU • Please fill out this water meter worksheet and send it to UBOnlinePay a@tigard-or.gov: https://www.tigard- or.gov/document center/UtilityBilling/Water MeterWorksheet-Additions Remodels ADUs.pdf o Utility Billing will review your worksheet and let you know if you need to upsize your water meter. Please include a copy of their response with your building permit submittal. 2 • Building:Can you please respond and let Ed know what the best way is for him to submit all his building permit materials? Please let us know if you have any questions. Thank you, Lina Smith Assistant Planner City of Tigard I Community Development 13125 SW Hall Blvd.Tigard, OR 97223 E-mail: LinaCS@tgard-or.gov From: ed@thetoews.com <ed@thetoews.com> Sent: Friday, November 20, 2020 4:46 PM To: Planner on Duty<tigardplanneronduty@tgard-or.gov>;#Building Permit Technicians <Tigard BuildingPermits@tgard-or.gov> Cc: 'Jordan'<Jordan@TheToews.com>; Allyson Armstrong<AllysonA@tgard-or.gov> Subject: RE: Building permit application Hi Lina, Thank you very much for getting back to me so promptly. Please see attached. ed Ed Toews I +1.317.863.9776 (h); +52(1)668.187.85.22 (m); +1.503.702.9503(c) From: Planner on Duty<tigardplanneronduty@tgard-or.gov> Sent: November 20, 2020 4:41 PM To: ed@thetoews.com;#Building Permit Technicians<TigardBuildingPermits E(ltigard-or.gov> Cc: 'Jordan' <Jordan@TheToews.com>; Planner on Duty<tigardplanneronduty@tgard-or.gov>;Allyson Armstrong <AllysonA@tiga rd-o r.gov> Subject: RE: Building permit application Hi Ed, Can you please re-send the documents to me? Looks like you previously sent them to the Building Division but Planning hasn't seen the revised documents. I'll take a look at them and review them with my supervisor on Monday. Thank you, Lina Smith Assistant Planner City of Tigard Planning Division 13125 SW Hall Blvd.Tigard,OR 97223 Phone: (503)718-2421 E-mail:tigardplanneronduty@tigard-or.gov From: ed@thetoews.com <ed@thetoews.com> Sent: Friday, November 20, 2020 4:29 PM To:#Building Permit Technicians<TigardBuildingPermits@tgard-or.gov> 3 • Cc: 'Jordan'<Jordan@TheToews.com>; Planner on Duty<tigardplanneronduty@tigard-or.gov>; Allyson Armstrong <Al lysonA@tiga rd-o r.gov> Subject: RE: Building permit application Hi again, We trust you have received the email below. We did not get a confirmation of receipt so wonder if the attachments prevented the email from getting through. Please let us know if we should have applied using a different mechanism. Thanks, ed Ed Toews I +1.317.863.9776 (h); +52(1)668.187.85.22 (m); +1.503.702.9503(c) From: ed@thetoews.com <ed@thetoews.com> Sent: November 3, 2020 10:26 AM To: tigardbuildingpermits@tigard-or.gov Cc:Jordan <Jordan@TheToews.com> Subject: FW: Building permit application Hi again, When applying for the SDC exemption, we learned of the 1,000ft2 limit on the size of ADUs eligible for exemption. Our previous application listed the ADU as 101oft2. While investigating where we could reduce the extra 10ft2, we realized we made a calculation error and the planned ADU is 910ft2, not 1,01oft2. Attached please find the same documents as we submitted previously, but with the ADU area numbers and signature dates updated as needed.The changed documents are indicated in the table included in the email below. Please accept our apologies for this confusion, ed Ed Toews I +1.317.863.9776 (h); +52(1)668.187.85.22 (m); +1.503.702.9503(c) From:ed@thetoews.com <ed@thetoews.com> Sent:October 27, 2020 4:02 PM To: 'tigardbuildingpermits@tigard-or.gov' <tigardbuildingpermits@tigard-or.gov> Cc:Jordan <Jordan@TheToews.com> Subject: Building permit application Hi folks, We are homeowners converting a basement in an older house into an ADU. We have been working through the process with a number of your staff and trust the attached is at least close to what you need to provide a permit for this work. If there is a more formal process for submitting, please let us know.The state website does not seem to allow us to sign on because we are just engineers, and not licensed tradesmen. We have not received an SDC exemption but have attached a copy of the application. We struggled with the fee sections, especially on the building permit application. We assume you will be providing an itemized invoice. List of Permit Documents Document Purpose Order Receipt 6739771 Receipt fo payment of Development Permit Fee Re: New Address Application Confirmation of new ADU address from Mr. Oscar Contreras BldgPermitRvw_RES_122419 SDC Exemption Application* 2020-10-30 ADU Drawings Drawing package* Gas Pipe Sizing Pressure loss calculations for new gas loads 4 Gas Piping Schematic Piping diagram to support pressure loss calculations Permit_Applications_Signed Permit applications for all disciplines* *One or more sheets modified in this document We are looking forward to working on this project. Thanks for all your help so far, ed Ed Toews I +1.317.863.9776 (h); +52(1)668.187.85.22 (m); +1.503.702.9503(c) https://www.linkedin.com/iniedtoews/ DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained by the City of Tigard in compliance with the Oregon Administrative Rules"City General Records Retention Schedule." 5 Dianna Ornelas From: #Building Permit Technicians Sent: Wednesday, December 23, 2020 6:07 PM To: ed@thetoews.com Cc: 'Jordan' Subject: RE:Toews ADU - 12185 SW Plantation Terrace Attachments: SKM_C65920122317550.pdf; OwnersConstructionResponsibilities.pdf Hello Ed, Your plans are being routed for review, however I did notice that the electrical permit application is missing your signature in the 'owner installation' section. Please see attached application for signature. Also, because you are performing all of the work as owner, we will need you to complete the state owner construction responsibilies form. Please complete the attached form. Please email both forms to TigardBuidingPermits@tigard-or.gov. Thank you! Dianna L. Ornelas Building Division Services Supervisor City of Tigard I Community Development 13125 SW Hall Blvd I Tigard, OR 97223 503-718-2430 Direct 1503-718-2439 Permits From: Lina Smith <LinaCS@tigard-or.gov> Sent: Wednesday, December 16, 2020 1:08 PM To:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov>; ed@thetoews.com Cc: 'Jordan' <Jordan@TheToews.com>; UB Online <UBOnlinepay@tigard-or.gov> Subject: RE:Toews ADU - 12185 SW Plantation Terrace Hi Ed, I just finished the Planning/Zoning check for this one and routed it to Building for processing. If you have any questions about your permit, please contact them at tigardbuildingpermits@tigard-or.gov or(503) 718-2439. Thank you, Lina Smith Assistant Planner City of Tigard I Community Development 13125 SW Hall Blvd.Tigard, OR 97223 E-mail: LinaCS@tigard-or.gov From:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Sent: Monday, December 14, 2020 6:19 PM To: ed@thetoews.com Cc: 'Jordan'<Jordan@TheToews.com>; UB Online <UBOnlinepay@tigard-or.gov>; Lina Smith <LinaCS@tigard-or.gov> 1 Subject: RE: Toews ADU - 12185 SW Plantation Terrace Importance: High Hi Ed, I have received the permit application packet and will route to Lina for review, however I need to know about the water meter. Did you actually submit a water meter worksheet to UB and get their approval? My apologies as I cannot find where this item was completed and I need to know what the outcome of that review was. Does the meter need to be upsized? You need this resolved before we route the plans for review because the plan review fee is non-refundable if you decide to not go through with this project because of the additional water meter costs. Thank you. Dianna L. Ornelas Building Division Services Supervisor City of Tigard I Community Development 13125 SW Hall Blvd I Tigard, OR 97223 503-718-2430 Direct 1503-718-2439 Permits From: ed@thetoews.com <ed@thetoews.com> Sent:Thursday, December 10, 2020 6:15 PM To: Lina Smith<LinaCS@tigard-or.gov> Cc: 'Jordan' <Jordan@TheToews.com>; #Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Subject: RE:Toews ADU - 12185 SW Plantation Terrace Warning!This message was sent from outside your organization and we are unable to verify the sender. J Thanks Lina. Dropped the plans off today in hopes of getting an early start next week. ed Ed Toews I +1.317.863.9776 (h); +52(1)668.187.85.22 (m); +1.503.702.9503(c) From: Lina Smith <LinaCS@tigard-or.gov> Sent: December 10, 2020 5:07 PM To: ed@thetoews.com Cc: 'Jordan' <Jordan@TheToews.com>; #Building Permit Technicians<TigardBuildingPermits@tigard-or.gov>; Mai Quach <maiq@tigard-or.gov>; UB Online<UBOnlinepay@tigard-or.gov> Subject: RE:Toews ADU - 12185 SW Plantation Terrace Thanks Ed. I can get started on the Planning/Zoning review while we wait for the items you listed in your e-mail. Just FYI our office is closed on Fridays. Have a good weekend, Lina Lina Smith Assistant Planner City of Tigard I Community Development 13125 SW Hall Blvd.Tigard, OR 97223 E-mail: LinaCS@tigard-or.gov 2 From:ed@thetoews.com <ed@thetoews.com> Sent:Thursday, December 10, 2020 4:55 PM To: Lina Smith <LinaCS@tigard-or.gov> Cc: 'Jordan' <Jordan@TheToews.com>; #Building Permit Technicians<TigardBuildingPermits@tigard-or.gov>; Mai Quach <maiq@tigard-or.gov>; UB Online <UBOnlinepay@tigard-or.gov> Subject: RE: Toews ADU - 12185 SW Plantation Terrace Hi Lina, This afternoon, we dropped off the plans, calculations, and diagrams, but not the exemption covenant or the water meter confirmation.There are a couple of issues: 1. Washington County would not record the SDC exemption covenant because the document was missing the signature of the interim city manager. We are working with Ms. Quach to get this resolved. 2. Utility billing has confirmed our water meter is only 5/8" and is now determining our path forward. The ADU changes we are making should not have triggered a meter change but the existing meter was undersized for the existing house water load. We will bring the remaining documentation over once the issues are resolved. Please let us know if there is anything else needed. Thanks for your help, ed Ed Toews I +1.317.863.9776 (h); +52(1)668.187.85.22 (m); +1.503.702.9503(c) From: Lina Smith <LinaCS@tigard-or.gov> Sent: November 24, 2020 11:17 AM To:ed@thetoews.com Cc: 'Jordan' <Jordan@TheToews.com>; #Building Permit Technicians<TigardBuildingPermits@tigard-or.gov>; Allyson Armstrong<Al ysonA@tigard-or.gov>; Mai Quach <rnaiq@tigard-or.gov> Subject:Toews ADU - 12185 SW Plantation Terrace Hi Ed, Sorry for the delay in getting back to you. I reviewed your revised floor plans with my supervisor, and confirmed that the ADU is under 1,000 square feet in size.Just FYI we measure floor area from the outside of the exterior walls; regardless, the ADU is still under 1,000 square feet in size. We'll need to wait until Mai's finished with your SDC exemption paperwork before Building can start processing your building permit application. In the meantime, please work on the following items: • Please revise your building permit applications with the 12185 address for the ADU • Please fill out this water meter worksheet and send it to UBOnlinePay@tigard-or.gov: https://www.tigard- or.gov/document center/UtilityBilling/Water MeterWorksheet-Additions Remodels ADUs.pdf o Utility Billing will review your worksheet and let you know if you need to upsize your water meter. Please include a copy of their response with your building permit submittal. Building:Can you please respond and let Ed know what the best way is for him to submit all his building permit materials? Please let us know if you have any questions. Thank you, Lina Smith Assistant Planner 3 1 City of Tigard I Community Development 13125 SW Hall Blvd. Tigard, OR 97223 E-mail: LinaCS@tigard-or.gov From: ed@thetoews.com <ed@thetoews.com> Sent: Friday, November 20, 2020 4:46 PM To: Planner on Duty<tigardplanneronduty@tigard-or.gov>; #Building Permit Technicians <Tiga rd BuildingPerm its@tigard-or.gov> Cc: 'Jordan'<Jordan@TheToews.com>; Allyson Armstrong<AllysonA@tigard-or.gov> Subject: RE: Building permit application Hi Lina, Thank you very much for getting back to me so promptly. Please see attached. ed Ed Toews I +1.317.863.9776 (h); +52(1)668.187.85.22 (m); +1.503.702.9503(c) From: Planner on Duty<tigardplanneronduty@tigard-or.gov> Sent: November 20, 2020 4:41 PM To: ed@thetoews.com; #Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Cc: 'Jordan'<Jordan@TheToews.com>; Planner on Duty<tigardplanneronduty@tigard-or.gov>; Allyson Armstrong <AllysonA@tigard-or.gov> Subject: RE: Building permit application Hi Ed, Can you please re-send the documents to me? Looks like you previously sent them to the Building Division but Planning hasn't seen the revised documents. I'll take a look at them and review them with my supervisor on Monday. Thank you, Lina Smith Assistant Planner City of Tigard Planning Division 13125 SW Hall Blvd.Tigard, OR 97223 Phone: (503) 718-2421 E-mail:tigardplanneronduty@tigard-or.gov From:ed@thetoews.com <ed@thetoews.com> Sent: Friday, November 20, 2020 4:29 PM To:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Cc: 'Jordan' <Jordan@TheToews.com>; Planner on Duty<tigardplanneronduty@tigard-or.gov>; Allyson Armstrong <AllysonA(a tigard-or.gov> Subject: RE: Building permit application Hi again, We trust you have received the email below. We did not get a confirmation of receipt so wonder if the attachments prevented the email from getting through. Please let us know if we should have applied using a different mechanism. Thanks, ed 4 , 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A i Combnatbn Boier i d Fireplace Cbthes Dryer(fut) Coolmop Fireplace (fut) B i o O El .© ;` ,._; ,000 25,000 33,000 30,000 40BTU/Hr BTU/Hr BTU/Hr BTU/Hr 180,000 C x BTU/Hr g g g g - zn M Bo — V in ul n H in O O D o 0 0 m OA 1"-12' 1"-4' Did 0.75"-6' 0.75"-10'Flex'' 1.25"x 6' 1.25 x 1 x 0.75 1 x 1 x 0.5 1 x 0.75 x 0.5 0.75 x 0.5 x 0.5 E 0.75 x 0.75 x 0.5 1.25x 1.25x1 p1 i 1"-2' Mu ?'-45' •• in F 43,000 �� o 1 BTU/Hr N G 40,000 BTU/Hr L. H BBQ Outlet Meter Author: Fie: Gas Piping Schematic Date: Fob:: 3/3 • Supply Pressure 6.5 S.G 0.6 Pressure Length Minimum Spitzglass Formula Pressure Length Segment Spitzglass Formula BTU/hr Min. Drop Feeder Size d k Flow Cumulative Drop Trunk Size d k Flow CookTop(existing) 43,000 4 2.5 59 0.5 0.622 0.116954 110.3348 401,000 1.5 85 1.25 1.38 1.17097 712.9096 Combi-boiler 180,000 3.5 3 26 0.75 0.824 0.265365 413.1457 356,000 1.5 85 1.25 1.38 1.17097 712.9096 Fireplace(existing) 40,000 4.5 2 34 0.5 0.622 0.116954 130.0002 178,000 1.5 85 0.75 0.824 0.265385 161.5718 Dryer(future) 25,000 5 1.5 40 0.5 0.622 0.116954 103.7969 138,000 1.5 85 0.75 0.824 0.265365 161.5718 BBQ(future) 40,000 5 1.5 45 0.5 0.622 0.116954 97.86063 113,000 1.5 65 0.75 0.824 0.265385 161.5718 ADU Cooktop 33,000 5 1.5 64 0.5 0.622 0.116954 82.05863 73,000 1.5 85 0.75 0.824 0.265385 161.5718 ADU Fireplace(future) 40,000 5 1.5 85 0.5 0.622 0.116954 71.20407 40,000 #N/A #N/A #N/A Total 401,000 Nominal ID 0.5 0.622 0.75 0.824 1 1.049 ' 1.25 1.38 1.5 1.61 2 2.067 I.