Loading...
Plans N 13058 Sw Black Walnut St ARRAY DETAILS: _ MOUNTING PLANE: AZIMUTH: TILT: MP1 180° 22° /� J 470" 18'-6" DRIVEWAY FRONT OF HOME / 1 CONTRACTOR INFORMATION: SUNWARD POWER MEI 9182 SE HAMILTON LANE li 0 HAPPY VALLEY,OR 97088 License#238152 I ❑ o (M.MSP PqC 94' QII - I 0000 — V — 81'-8" 00 + I SITE INFORMATION I AMBER MCPHERSON 13058 SW BLACK WALNUT ST MP1 _ I TIGARD,OR 97224 AC SYSTEM SIZE:10.08 KW AC DC SYSTEM SIZE:10.9 KW DC LAT,45.4081531 LONG,-122.8112694 (18)SILFAB SIL•400 HC+ PV MODULES 0.0)SILFAB SIL•370)IC PV MODULES — — (14)CHILICON CP-720 INVERTER(S) 58'-11" I EQUIPMENT LEGEND: VISIBLE,LOCKABLE, DRAWN BY:SoloCAD nc 0 UTILITY METER VISIBLE,LOCKABLE,LABELED ® INVERTER 3 SUB PANEL so SERVICE DISCONNECT ❑ PV MODULES FIRE ACCESS PATHWAY(3'TYP) LABELED AC DISCONNECT 7/24/2023 AC DISCONNECT LOCATED WITHIN 10' I�4; MAIN SERVICE PANEL METER SOCKET c COMBINER BOX 0 LOAD CENTER EA: BATTERY(IES) m JUNCTION BOX PROPERTY LINE OF UTILITY METER SITE PLAN-PV02 (FOR UTILITY PV METER) I L.J • S N// CONTRACTOR INFORMATION: SUNWARD POWER 9182 SE HAMILTON LANE HAPPY VALLEY,OR 97086 r i MSP License#238152 AC — 1'-0" ❑ n ❑ ❑ o - e I . p0 00 SITE INFORMATION 0 CI AMBER MCPHERSON 13058 SW BLACK WALNUT ST TIGARD,OR 97224 AC SYSTEM SIZE: 10.08 KW AC j DC SYSTEM SIZE: 10.9 KW DC LAT,45.4081531 LONG,-122.8112694 3-0" (1B)SILFAB SIL-400 HC• PV MODULES I10)SILFAB SIL-370 HC PV MODULES EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: (14)CHILICON CP-720 INVERTERS) RACKING MANUFACTURER: IRONRtDGE ROOF TYPE: ASPHALT SHINGLE PV MODULE COUNT: 28 RACKING PART NUMBER: XR ROOF FRAMING: MANUFACTURED TRUSS ARRAY AREA: MODULE COUNT•21.34 FT'=597.52 ATTACHMENTS FLASHVUE RAFTER/TOP CHORD SIZE: 2x4 ROOF AREA: 1631 FT' ', ATTACHMENT QTY: 72 RAFTER/TOP CHORD SPACING: 24" PERCENT OF ROOF COVERED: 37% DRAWN BY:SoloCAD SPLICE QTY: 4 ATTACHMENT SPACING: 48" ARRAY WEIGHT: MODULE COUNT•47 LBS=1316 LBS 7/24/2023 MIDCLAMP QTY: 38 POINT LOAD: ARRAY LBS/ATTACHMENTS=18.28 ENDCLAMP QTY: 36 DISTRIBUTED LOAD:(Ibs/ft') ARRAY WEIGHT/AREA 2.2 LBS/FT° ROOF PLAN-PV03 END CLAMP MID CLAMP © © 7 PV MODULE PV MODULE FRAME / / //-RAIL Elk RAIL l 1=t ---__. t - RAIL �'!- -. --- ,;, 14 j SL I�rwa (-8 ! MAX°SPAN ! Nq{\ `MAX \ OEND CLAMP DETAILS O MID CLAMP DETAILS FRONT VIEW (E)RAFIERrro9CHORGs CONTRACTOR INFORMATION: SUNWARD POWER 9182 SE HAMILTON LANE PV MODULE HAPPY VALLEY,OR 97088 License#238152 RAIL RAIL s_ ATTACHMENT (E)COMP SHINGLE ROOF(1 LAYER) 10"MIN- 11 I'� 1'4" 7MAX 10"MIN- --�=- 7-0"MIN- 1�-4 -� ATTACHMENT JI 8'-10"MAX MAX r :'• FLA31LING(SEEDA7ASHEE7 F00.DETAILS) 2'-8"MIN• SITE INFORMATION AMBER MCPHERSON 5/16"STAINLESS STEEL LAG BOLT 3'-10"MAX WITH 2-1/2"MIN.EMBEDMENT 13058 SW BLACK WALNUT ST (plat MANUFACTURER) (E)RAFTER/TOP CHORD TIGARD,OR 97224 (E)RAFTER/TOP CHORD AC SYSTEM SIZE: 10.08 KW AC O DETAIL, MOUNTING AND FLASHING SIDE VIEW DC SYSTEM SIZE i DC UT,45.4081 10.9531 DC LONG,-122.8112894 (18)SILFA8 NI.-400 HC+ PV MODULES (10)SILFAB OIL-370 HC PV MODULES EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA: (14)CHIUCON CP-7201NVERTER(S) RACKING MANUFACTURER: IRONRIDGE ROOF TYPE: ASPHALT SHINGLE PV MODULE COUNT: 28 r ` RACKING PART NUMBER: XR ROOF FRAMING: MANUFACTURED TRUSS ARRAY AREA: MODULE COUNT•21.34 FT°=597.52 _- ATTACHMENTS FLASHVUE RAFTER/TOP CHORD SIZE: 2x4 ROOF AREA: 1631 FT' , r ATTACHMENT QTY: 72 RAFTER/TOP CHORD SPACING: 24" PERCENT OF ROOF COVERED: 37% DRAWN BY:SOIOCAD SPUCE QTY: 4 ATTACHMENT SPACING: 48" ARRAY WEIGHT: MODULE COUNT•47 LBS=1316 LBS 7/24/2023 MIDCLAMP QTY: 38 POINT LOAD: ARRAY LBS/ATTACHMENTS=18.28 ENDCLAMP QTY: 36 DISTRIBUTED LOAD:(Ibs/R°) ARRAY WEIGHT/AREA=2.2 LBS/FT' MOUNTING DETAIL-PV04 • SILFAB OIL•400 HC+SPECS CHIUCON CP.720 SPECS EQUIPMENT SCHEDULE CONDUIT&CONDUCTOR SCHEDULE POWER MAX IPMAXI: 400W NM MINT VOLTAGE: 110V TYPE Q1V DESCRIPTION RATING TOSS On WIRE GAUGE DESCRIPTION CONDUIT SIZE OPEN GROAT VOLTAGE HOC): 4S.02 V MAX DCSHORTORCUT CURRENT: USA MODULES: (16) 51LFA6 SULFA&AI.100 HC+ 100W 1 121 12.2 PV-WIRE,USE-1 COPPER.(L1,1.2) N/A-NI[l AIR AY M POWER'POINTCURRENTIIMPI: 11.1A MAXIMUM OUTPUT POWER: 720W MODULES: ISO) SILFAS SILFAB SR-370 NC 370W II) I AWG MIRE COPPER-(GROUND) I MAXPOWERJOINT VOLTAGE(VMPR SECS MAXIMUMOUTPUTCURR0IT: IA INVERTER£ (11) MILICONCP.720 72GW 2 (2) 10 MG TNHN/THWN.2COPPER-(1.1,12) : SNORTGRCUIT CURRENT(ISCI: 11.58A NOM.OUTPUT VOLTAGE: 210V AC DISCONNECT'S): II) PV AC DISCONNECT,210V,2-POLE 60A (1) 10AWG THWN-23�Y EMT COPPER-(GROUND( SUf1W�if9 SERIES FUSE MONO: RDA MAX UNITS PER 3M CIRCUIT: I AC COMBINER: (1) PV AC COMBINER SODA S (6) 10 AWG THHN/THWN-2 COPPER-IL1,L2) BN,EMT rY 1-PHASE 60 NZ,UL 1741 USTED (1) 10 AW THWN-2 COPPER{GROUND) SILEAB SII-370 BC SPECS 1 13) I LW! THWN-2 COPPER-01,12,NEUTRAL) R//'BRAT POWER ARAM MOM): STOW IS) BAWD THWN-2 COPPER•(GROUND) OPEN CIRCUIT VOLTAGE(HOC): 41.T5 V MAX POWER-FV1Nr CURRENT DMPU 10.6A _ CONTRACTOR INFORMATION: MAX WER-PONTVOLTAOEIVNW): 349SV ROOFTOP TO COMBINER PANEL SUNWARD POWER SHOAT MLR CURRENTIL4): 112514 L=45 FT(ONE-WAY) 9182 SE HAMILTON LANE SERIES FUSE RATING. 20 A R=1.21 OHM5/1000FT I=3 A(PER MICRO INVERTER) HAPPY VALLEY, 97088 OPERATING VOLTAGE=240V License#238162 STRING VOLTAGE DROP ROOFTOP TO COMBINER PANEL:=0.95% = V(DROP)•(I.2L'R) COMBINER PANEL TO INTERCONNECTION:=0.26% = 21=2.45,0.00121 COMBINED AC VOLTAGE DROP:1.21%<2% = 2.29V SIRING(3):3o MODULES %V.V(DROP)/OPERATING VOLTAGE 2.29/240 =SUPPLY SIDE CONNECTION' I•MI I I I = 0.95% NEC 230.46,NEC 230.79&NEC 1�1 � r (NI SODA 705.11 10,110/240 VAC �i SINVERTERS AC COMBINER BOO (E)200A MAIN SERVICE PANEL TO U l T"GRIO L_ L F-- SOLAR LOADS ONLY PV AC DISCONNECT LA,, UL 1741 COMPLIANT STRING 1):B MODULES NEMA RP /� I - bon LASED, ( 1.80X 1 VISIBLE,LOWANE. (E)200A-2P I LABELED,OPEN 0 11111 En ism IAII I • 260V,2-POLE - L t� 4INVERTERS L i $ 11 ' T- ___ ____�____� (N)SCA FUSES (E)L0A05 SITE INFORMATION 1 ^ STRING(1):10 MODULES NEMA 3P I - r � AMBER MCPHERSON _— __ 1.10)1 OI (B120A-2P m./Y� 1" 411111 130585W BLACK WALNUT ST EOM MIME — _may_ - --��—��—— F 1 TIGARD,OP 97224 Tim 5INVERTERS / $ i R—_ r—1 I I AC SYSTEM SIZE:30.08 KW AC L_ I f____ 1_t—_-- -- __ {g}1 I DC SYSTEM SIZE:10.9 KW DC NEMA 9R NEMA 3R LJ 4 1 f� — LAT,45.4081533 1•BOX 2 13GX 3 L -G) LONG,-122.8112694 COMBINER PANEL TO INTERCONNECTION (El GROUNDING (E) UTILITY METER (18)51LFA8 SIL-400 HC+ L=15 FT(ONE-WAY) ELECTRODE PV MODULES R.0.491 OHMS/1000FT 3- (10)SILFABSIL-370 HC I=42A PV MODULES OPERATING VOLTAGE=240V I (14)CHILILICON CP-720 INVERTERS) COMBINER PANEL TO INTERCONNECTION VOLTAGE DROP = V(DROP).(1.2L=R) • 42'2"15=0.000491 = 0.62V I' A 1 _ 'iv=V(DROP)/OPERATING VOLTAGE VISIBLE,LOCKABLE, DRAWN BY:SOIDCAD = 0.62/240 LABELED AC DISCONNECT 7/24/2023 = 0.26% LOCATED WITHIN 10' OF UTILITY METER LINE DIAGRAM-PVDS A STRING CALCULATIONS SYSTEM OCPD CALCULATIONS [Nilson CP-720 STRING 81 STRING N2 INVERTER MODELISI: CHILICON CP-720 MAX AC CURRENT: 15.00A 12.00A N OF INVERTERS: 19 MICRO INVERTERS IN SERIES 5 4 MAX OUTPUT CURRENT: 3A NOMINAL STRING VOLTAGE: 240V 240V (R OF INVERTERS/XMAX OUTPUT CURRENT)X 12S%K.0CPD RATING S unWa °. tl MAX AC OUTPUT POWER 3600W 2880W 114 X 3A X 1.25).52.5Ao-WA,OK ARRAY DC POWER: 132W W SUPPLY SIDE INTERCONNECTION TOTAL MAX AC CURRENT: 42.00A MAIN BUSBAR RATING: 200A NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES MAIN DISCONNECT RATING: 200A 4-6 .80 PV°CPO RATING: 60A CONTRACTOR INFORMATION: 7.9 .70 SERVICE RATING.PV OCPD SUNWARD POWER 10-20 .50 200A, 50A,OK. 8182 SE HAMILTON LANE CONDUIT&CONDUCTOR SCHEDULE HAPPY VALLEY,OR 97085 TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SUE CONDUCTOR WPM CONDUCTOR TEMP.RATE AMBIENT TEMP TEMP.DERAIL ROFCOMWC7OR5 CONDUCTOR RATING CONDUIT FILL License DERATE W/DERATES (2) ll I -2 PV-WIRE,USE-2 COPPER-(li,L?) 1 N/A-FREE AIR 30A 90't 32'C 0.46 N/A-FREE AIR 28.8A N/A-FREE AIR (1) 6AWG BARE COPPER-(GROUND) 2 II) 10 AWG THHN/THWN•2 COPPER-(Ll,Q) 3/4"EMT 40A 90"C 32'L 0.96 1 38.4A 11.9% (1) 10 AWG THWN-2 COPPER-(GROUND) 3 (A) 10 AWG THHN/TNWN-1 COPPER.ILL12) 3/4"EMT WA 90'C 32'C 0.96 0.8 30.72A 27.8% (1) 10 AWG TNWN-2 COPPER-(GROUND) 4 (3) 6 AWG TNWN-2 COPPER-(LI,L2,NEUTRAL) 3/4"EMT 65A 75'C 32'C 0.99 1 61.1A 36.5% (1) 8AWG THWN-2 COPPER-(GROUND{ SITE INFORMATION AMBER MCPHERSON 13058 SW FLACK WALNUT ST TIGARD,OR 97224 AC SYSTEM SIZE: 10.08 KW AC DC SYSTEM SIZE: 10.9 KW DC LAT,45.4081531 LONG,-122.8112694 (18)SILFAB SIL-400 HC• GROUNDING&GENERAL NOTES: INTERCONNECTION NOTES: PV MODULES 1. PV INVERTER IS UNGROUNDED,TRANSFORMER-LESS TYPE. 1.GROUND FAULT PROTECTION IN ACCORDANCE WITH}NEC 215,9)&}NEC 230.95) (10)SV M SIL-370 HC P 2.DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 2.SUPPLY SIDE INTERCONNECTION ACCORDING TO (NEC 705.11}WITH SERVICE ENTRANCE CONDUCTORS IN PV O_-ULES 3.ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE ACCORDANCE WITH(NEC 240.21) (141 CHILICON CP-720 INVERTER(S) , INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4.JUNCTION BOX QUANTITIES,AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD- DISCONNECT NOTES: JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 1.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS 5,AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS) DRAWN BY:SoloCAD AC DISCONNECTING MEANS IS LOCATED WITHIN 10'OF SERVICE DISCONNECT. 2.AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL BE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH, 7/24/21)23 3,FUSED AC DISCONNECT TO BE USED. ELECTRICAL CALCS-PV06 MAIN PHOTOVOLTAIC AB2u PHOTOVOLTAIC AC DISCONNECT LABEL PLACED ON THE MAIN DISCONNECTING MEANS FOR THE PV RWERTb AT AC DISCONNECTING MEANS, SYSTEM DISCONNECT INE 690.13(8)) RATED AC OUTPUT CURRENT: mai. [NEC690.541 NOMINAL OPERATING AC VOL TAG E.ME LABEL Sur w�► AT DIRECT-CURRENT EXPOSED RACEWAYS,CABLE TRAYS,COVERS AND PHOTOVOLTAIC POWER SOURCE ENCLOSURES OF JUNCTION BOXES,AND OTHER WIRING METHODS;SPACED .A, �LAABBft��� AT MAXIMUM Sr SECTION OR WHERE SEPARATED BY ENCLOSURES,WALLS, F I OSYONNECDNG MEANS WHERE THE LINE AND PARTITIONS,CEILINGS,OR FLOORS. ELECTRIC SHOCK HAZARD LOAD TERMINALS MAY BEENERGI2EDIN THE OPEN [NECBBG31)D)R)) TERMINALS ON THE LINE AND [NEC OSITION131BX SOLAR PV SYSTEM EQUIPPED CONTRACTOR INFORMATION: WITH RAPID SHUTDOWN LABELS SUNWARD POWER LOAD SIDES MAY BE ENERGIZED POAPPSTEMS THAT SHU DOWN THE ARRAY ANDCONDUCTORS 9182 SE HAMILTON LANE LEAVING THE ARRAY: IN THE OPEN POSITION SIGNTOBELOCATEDONORNO MORE THAN 3FT AWAY FROM HAPPY VALLEY,OR 97086 TURN RAPID SHUTDOWN SERVICE DISCONNECTING MEANS WHICH THE PV SYSTEMS ARE SWCH TO THE"OFP' A CONNECTED AND SHALL INDICATE THE LOCATION Of ALL IDENTIFIED License#238152 POSITION TO SHUT DOWN RAPID SHUTDOWN SWITCHES IF NOT ATTXE SAME LOCATION. LABEl3 (NEC 6B0.S6(C)(111 AWARNING FCFC5SADJADENTTD HE BACK ED BREAKER FROM PV SYSTEM AND REDUCEii 113E INVERTER JF TIEIN CONSATS Of LOAD 510E SHOCK HAZARD IN ARRAY ` POWER SOURCE OUTPUT CONNECTION. CONNECDON TO BUSBAR. NOT RELOCATE THIS OVERCU (NEC'/tl5.f2(Bj191(21] C _ LAEEL4 RAPID SHUTDOWN LABEL9 I K U ` !DCRSL ON EQUIPMENT CONTAINING OVERCURRENT SIGN LOCATED ON OR NO MORE THAN 3FT DEVICES IN CIRCUITS SUPPLYING POWER TO SWITCH FOR FROM INITIATION DEVICE MULT .. N R ABUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE [NEC 690.561CX211. `� SOURCES nn NNEC7o5.101 SOLAR PV SYSTEM Tr- N LABEL S DEVICES TCONTAINING OVERCURRENT THIS EQUIPMENT IS FED BY MULTIPLE SUSBAARR ORaCwro2UcToORR SUPPLIPOWER D NOM A SOURCES.TOTAL RATING OF ALL MULTIPLE SOURCES SHALL BE MARKED TO -- INDICATE THE PRESENCE OF ALL SOURCES,INE[ SITE INFORMATION OVERCURRENT DEVICES,EXCLUDING JOS.12IB)I3X3II MAIN SUPPLY OVERCURRENT AMBER MCPHERSON DEVICE,SHALL NOT EXCEED 13058SW BLACK WALNUT ST AMPACITY OF BUSBAR. TIGARD,OR 97224 AC SYSTEM SIZE:10.0E KW AC DC SYSTEM SIZE: 10.9 KW DC LABELING DIAGRAM: MAIN SERVICE PANEL LAT,45.4081531 TONG,422.BI12694 PV COMBINER EXISTING SUB PANEL O (18)SILFAB SIL-400 HCt SUBPANEL•IF USED TO (ONLY IF WHERE POINT O PV MODULES COMBINE PV OUTPUT OF INTERCONNECTION CIRCUITSORINVERTER AC DISCONNECT IS MADE) O (10)51LFAB SiI-370 HC PV MODULES JUNCTION BOX ES-- O O © O O ® 114)CH:LIGON CP-720 INVERTER(S) = O O O 0 _ 3 O _ LABELING NOTES: El 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE O O 0 O EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS l PHUY IF PI (CNLNIfIN 2, LABELING REQUIREMENTS BASED ON TIE 2020 NATIONAL ELECTRIC CODE,05HASTANDARD INTIPLONNILTION NNRCONMCnoN DRAWN BY:SoloCAD CONSISTS MIMI, WIYSR R LAID 19ATERIA5,ANSISE2535. SIDE MAKER} SIDE BREAKER 3. MATERIAL BASED ON TOE REQUIREMENTS Of THE AUTHORITY HAVING JURISDICTION. 7/24/2023 4- LABELS TO BE OF SUFFICIENT DURABILITY TO WUHSTAND THE ENVIRONMENT INVOLVED(NEC 110.21) ' ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR IABEUNG PURPOSES ONLY.NOT AN ACTUAL REPRESENATION OF S. LABELS TO RE A MINIMUM LETTER HEIGHT OF 3/8",WHITE ON RED BACKGROUND;REFLECTIVE,AND EQUIPMENT AND CONNECTIONS TO BE INSTALLED.LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF LABELS-PV07 PERMANENTLY AFFIXED(NEC 690.31)DX211 INTERCONNECTION METHOD AND LOCATION PRESENTED ELECTRICAL DIAGRAM PAGE. P. CAUTION Sum, POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: N CONTRACTOR INFORMATION: ^j SUNWARD POWER FRONT OF HOME 9182 SE HAMILTON LANE HAPPY VALLEY,OR 97086 License#238152 MAIN DISTRIBUTION UTILITY DISCONNECT RAPID SHUTDOWN AC DISCONNECT SWITCH COMBINER 0 o 0 o 0 M— 0000 - PV ARRAY 11111=11 SITE INFORMATION 1„1_-„ AMBER MCPHERSON 111 2111 13058 SW BLACK WALNUT ST TIGARD,OR 97224 AC SYSTEM SIZE:10.08 KW AC 13058 Sw Black Walnut St,Tigard OR 97224 DC SYSTEM SIZE: 10.9 KW DC LAT,45.4081531 LONG,-122.8112694 (18) SILFAB SIL-400 HC DIRECTORY: PV MODULES (10)SILFAB SIL-370 HC PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION PVMODULES OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC (14)CHILICON CP-720 INVERTER(S) SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN:NEC 690.56(B)&(C), [NEC 705.10] DRAWN BY:SoloCAD 7/24/2023 PLACARD-PV08 SITE PHOTOS: 4 _ rl n51 1J ,ryl � \/�II ��Y ® :35idd � Ile ,. ''J Hq T U Yviki �` I 11.1 , `,1 CONTRACTOR INFORMATION: p 'I' j ®� 1 d 9182SUNWARD 9 HAMILTONER LANE 1&-.ve1 IRNRI9 M#14111 ,�, HAPPYLicense#2 8152 97086 M;,, " 3 I,. 11� VALLEY,OR Lo zoa owov v mzs sane L "" III 3]28]BO] — N I lit 11i'��,rl�lruid►ru�nr111t e , a -- • o A ? �' ., e ` + �, SITE INFORMATION YY .r' �, �B j,s r e '.- AMBER MCPHERSON *; atA 13058SWBLACKWALNUTST 24 I .- ll Y . i -- N. T R 9 Z• >' _ • AC SYSTEMR92B 30.08 KW AC " • .1 DC SYSTEM SIZE: 10.9KW DC LA),454083531 ' LONG,-1228112894 p ` (18)SILFABSIL-400NC* PVMODULES - (4 ,, (10)SILFAB SIL•370NC 'rit 3 PV MODULES T (14)CHIUCON CP.720 INVERTER(S)—__ i A DRAWN BY:SoloCAD `'- `� _ ' 7/24/2023 .. r SITE PHOTOS-PV09 RSCTMGI.SFldFICAT10M. SW Tat Conn.. STC MOO MCEYk Pew Moo wv II. We .• worn.V^./ .wltor Nona) v XIS WIC 1111= 00006 wamnmpowtanaPG'u ]1.10 CO ••• Ognwanwwp 6Ld elm .v» 51 LFAB • S-d OW ,., 5 O L A R• MauLMM"my L 1o1L 1laM umytwn.,uOM6g OM v slu0011[s Wmluv W11 A NOD wn..ml.ann Wo au.Lv Mammas W WMislc IMM'mt..W L].lone..ISC.or,L W,•./Y.15.Muu.enuYarsminb a]L Sun YU*.al**.ns....mmw from m,on*I„+WS r2wb1 onamon•norm woo by w.n5 paw 0e..1ow. NMI6MIGLPMHIT WINIIIIM WET61C 111%OML MnlWxela*t ]ly6M25 I albaap.IM. mmibns IX.'.a DI 1914 mma ION Mon NWmm TOM,•4031n.1.11 In o II mum a0M•Iw01Mnd NOON /movir R owl* IS.nk outlaw IS6+W Mr"tl10IM l llY'pant!ova -WIlmwe rev arcx ro min.ln knot •1m.14141* Cads USN I,W. .MW0IW POW L# I Nal W iln aWAc 1bW1.13.1B1mol Slab,1L[BsIln cYu v mmNyrvww+Mw,.ymny.nd• lain xMaamtnitullmm+cm.d. ow.W,Mwdw only mx.nuwsnn mama CAC.anoI connetton Irtfy to'noblhOar m•nwll 1]30 n01,.5.1mm•Mg1mn'WA SOIm•0.91nOYM41.WAh0In91.IL11 e.a.nm1 n wOm• wre^ANba.CS wow...,mwnyv0M0.aar nun. FM. WOW MoM(Ma) 0F•u0iWn 3doda 1911015TNW ma IXM.Wq.lN.155 ma lnulm MCMtl torrent) 1un3onva• VAIN CMMa1MCGRSCrlPMLls®..M iIMPIMMURE YMTMI66 i IMaMIITY rWreCv0Pclem la g501%VC blue gbla.v0Mnengp wrSmy 25yr.n•• emperelum coofficleoLN< dM.LY lima;Wooer Rob!mM¢wYfve. Myers "ETPSren'm GMtlatPma ..VC e9T.Lg'XI IWo /IOCT ll3'cl b2 [vLPhmd Woo d l Oa,u.+snore .yNS C 1 aSY690 moYq yr CIMTIfICATIONS 8M1PPIM6 SPECS ULBlE01:AL1 fA.]'••.Y11ll1.SeW11 F5.1•^.IIL4llF1.'IDtl[dl"•.LLLLTIY Ma0W.M PBIMC 35 a 161C.11k0Ml 0SOn sdl^.61.CR]M11o.11019 Oar.,CU 011601,30.2:91111LI*, Product IGItl0S1911i SOl".F.1.1,3 014 W1...w.MTA141116T••,MC 1 UT-MIMd2....ECell01®M.SMrfmmenl.wCRl1YA13MnW+J. . MA Per Truck uaumllkmm Cumlmj.&FlmY*ETIP.1,MEUMW' Rob,/ I 00116014103 Maws Per laa ON w sM lglrnnla jy a .s •w.nflbm.SMa.wlrawmlM 6W.abws ••••a5.6•lsont5s,eiMn r*wrl.a.0a _c » u0S.. .wbllmssv.emmseWm me wewwwl.M M. e+MM .wlm.0 teati .. MMrr.aml 5.l lod'My pawns..m•.*wobble Wand R nlba.l•.mr•SMlu.w ^cmlllfb•NIXYIMP M•ARanM]AyabOomMM•. 3 k�� Ir 11_1'pP11M111_. 611 111•RELIABLE ENERGY. \A.mMOlbMM J1) 0 SILPABSOLAR I4 DIRECT FROM THE SOURCE. (3°—_ ` '°PTWm"P"• / r MMM1/1.m1.4763 WA USA // nymt ta1N0lachocc om L .m11r...o1w.<v Designed to outperform. '� Dependable,durable,high-performance qqr�1 ) I m n1mn5.M9mus. solar panels engineered for North 1Aa S ❑ €'b�'' j iL • American homeowners. ' �L�- 1 � 00 East U $ IP�mM P.Lwe SILFABSOLAR.COM 8 1 Mwlaupox urinnMe. 1 13 r_-�� L _� 111ir�r5�fiW.e.w..ls 61Me W.16' •,19tl46vt5T �1 n+I•IV I ammM a. puny ! ..L..-—.I iLiC TILL encmunoxe 370 Tat co-am0. OK •••• IWw WetWmul Op NI 111=111111, •�•e• MOWN N•m.411eFm.s.t Otis lW SILFAB • NMnm wow mn RmW UM O yentlmA.05lP 04l A IL15 RY SOLAR waesomanmel•.1 ILls nO N w•Inmm• 1 • I 3•ne IA" Nobumbwmn.elMC1 1 V 1 34lerrey • 20 FS•••••••• Np 0m.lo liammae1AtivenC105••Far.•N16.M'P••••Y.WYF4WMysn'.IY.3.5.WuumwnumN_V4A MmeYwNRn'JmM,vaWJ•Aam Fr••••,ImMm.hema Mug..nor'1Wme•.tl psarby omPlW. NOOMMULPPMnnPLIci3OInnP MOWS IMnaMI 013•lYtlngIL•01 MIQMnIlml mmv55mm 54 inn Wba IX In 4••num0ulwlu•tlpMd/emwl' NANIN*M/601gfmlbtl 11.746/•2Ow d/II2B•••AVW NAMpeanu.Yna •a own•In WA •11OIIILi MO CO, Ii4 -lmteflt I]01Wo•R macRRC Srtl•-M•INmm 'Mar-Lamm In Om 13mm lipannlln0.nrm,.d. j OWb5W0Wl Il .miMY Mboml•1•••ml ow mirana mob( alnico end mi end nr In* manwp MOM%•S•mmW. M1ameuW U l Rh•0,nb1YWW.•G Nan MAD anduhen Me,dunmRn 4r0.a.rPmN6aaa W r•A•••.••••••rAWmk Wry 64o0••4ww13•14wl Frow uwamduunmenlgMul B•pndlides A e34s101L04v,IISV mai Miens nle •km'nJ eummO r nem..e ULMDearrlhd,III UM 4M16y IPo?Fated1.4 m rw TIMPWMTYn R4Tlll5 WMMIITISS T4.p,.LureCo0knllm .0.045(0 ewo1Le 5WMan4N0 wmmq o2ye•Y' I1A'4mrun 1OAtemW[ a.Mbrc l•me.pomp Prbnn•m•Planner nnXan 1 Ln ln2Mier1 pmu A.36914Y .541stA NOR�x 3Y a'C eiLm6end l'01yr Il.n2910T 0a0g1 empraWn VpWY •6xWm0 Mhm CeRTIMUTI0RS fuIpNMO STOP LIG Om CIM3.LLITtl,MC WV*,LA.BIIIL4-I-Vv.a61736µ*, •acula...Pell. 400126 KAMM•I pro.. I[CG311µbW...IEC d1y2.1/2.•,¢I C•110030-1/4te•,IEC62116 Immo*urr•.'m,IECLLmLM13Sh NY Corn trdbd,ll.FInRA1{Type l pe1W FMTrr,h Mo.1114YkrMal •odunrVTuh Mar=IGlibmid Irv**'ma t6•�.Ml•5MM•IIIF•1Mm•r•10141 R•tMiM•emMnl•Im0.lm•Iinma gnal{rr.W I5320 00ldbtl3•'•e111I•db.rPlnlYnwYmKNameun•IurrJ4•N41em(algllrbnl4am ^C4011Wn•IIN•M1 M/mY. I SILPA•NOUN INC. I. h Oh' . i f'.yyy•� T tlIICd m WOe O'L U$l —• r ID F 3380a6103.1 MaetlMaO laccom IS N.Y'laNnwl �'w � SILF.EISOL.SR.CON OPC0005•0S1ROrOM UM PONissans ONL.ST0gCHMd6 RELIABLE ENERGY. I I T* m"`01 DIRECT FROM THE SOURCE. ■ Introducing Silfab Prime 1`°`"� Molop.mal,ea:yddla,..Lan [ •dhrbmee.NpdeN u ma •x4 m y wlw.rrl5rm Designed to outperform. g Dependable durable,high performance solar panels •WN4a•4re•01wHmN engineered for North American homeowners. SILFABSOLAR.COM ® - - 4SAS.I wl.mY•• r6 vSNe.I ulY Row.] WPM.) • ,x REV720.20.01 Chilicon Power Microinverters CHILICON POWER CP-720 Dual Panel Microinverter CP-720TM Series Microinverters Performance •Supports up to 840W with no clipping(or 2x420W) The Chilicon CP-720 allows installers to • Maximizes energy production over life of system maximize PV system production, while • Minimizes losses due to shading and debris minimizing installation and operational • Eliminates single point of failure for system costs. Microinverter based architectures offer the benefit of increased flexibility in Simplicity panel deployment, while also providing per 'All AC design—No string calculations needed • No GEC needed for microinverters panel visibility to simplify system O&M. • Easy installation with standardized trunk cables With its all-AC approach, integrated grounding, modular bus cabling, and ability `ersatsiity to support up to 16 panels on a 30A branch • Compatible with most 60, 72, 96, 128 cell panels circuit, the CP-720 simplifies both design • Single SKU 240V or 208V and installation. Both freq-Watt and volt- •Allows for variable module placement Watt modes allow AC control by off-grid • Robust PLC communication protocol (500 ft range) systems. Coupled with Chilicon's CP-100 • Self supply mode (zero export) • Supports up to 30A branch circuits gateway and cloud based monitoring • Up to 20 panels possible on one branch circuit software, the CP-720 can form the energy management backbone of both residential Reliability, Safety, & Compliance and commercial PV systems. • NEMA 6 rated construction •25 year warranty •AC branch circuits will not support arc faults I. •Quick disconnect circuit to mitigate grid instabilities !ISO us • NEC 690.12 rapid shutdown compliant MADE IN USA 9001 Intertek • CA Rule 21 (UL 1741-SA) compliant Chilicon Powei www.chiliconpower.com r • CP-720-60/72/96-208/240-MC4 Microinverter Specifications INPUT DATA(DC) Recommended input power(STC) (190-420 W)x 2; (380-840 W)x 1 Maximum DC input voltage 120 V MPPT voltage tracking range 56-82 V(240V) 48.5-82 V(208V) Operating range 47-82 V Min./Max.start voltage 44-96 V Max. DC input short circuit current 16 A Max. DC input current 13.5 A Ground fault protection Transformer isolated 2000 Vrms input/output/chassis OUTPUT DATA(AC) @ 208 V @ 240 V Max.continuous output power 713 W 720 W Max.continuous output current 3.43 A(can be current limited to 2.66 A) 3.0 A(can be current limited to 2.4 A) Nominal output voltage/range 208/183-229 V 240/211-264 V Extended output voltage range 133/150/166-250 V 153/173/192-288 V Nominal frequency/range 60.0/59.3-60.5 Hz 60.0/59.3-60.5 Hz Extended frequency range 54.22-66.75 Hz* 54.22-66.75 Hz* Power factor -0.6 to 0.6 programmable -0.6 to 0.6 programmable Maximum units per 30 A branch circuit 7(14 modules)/9t(18 modules) 8(16 modules)/10t(20 modules) Maximum output overcurrent protection 6.3 A Fuse; 12A peak for 30 uSec 6.3 A Fuse; 12A peak for 30 uSec EFFICIENCY CEC weighted efficiency 96.1% Peak inverter efficiency 96.7% Static MPPT efficiency (EN 50530) 99.5%-99.8% Night time power consumption 100 mW; Standby Reactive Current<200mA MECHANICAL DATA Ambient temperature range -40° C to+65° C Dimension(W x H x D)including connectors 12" x 8"x 1.8" Weight 1.81 kg(4.0 Ibs) Enclosure rating NEMA 6 FEATURES Communication Mesh Networked Power Line(130.2 kHz carrier) Monitoring Monitoring via CP-100 gateway and Online Cloud UL1741, IEEE std 1547, IEEE std C62.41.2, CSA C22.2 NO. 107.1 Certifications CISPR 22 Class B; HECO Rule14H (Advanced Inverter), HECO Rule 22(Self-Supply) Rule 21/UL1741SA; Complies with NEC 690.12 Rapid Shutdown Product Warranty 25 Years 2 x Series 60/72 Cell Mono or Poly PV modules 2 x Parallel HV Panasonic Modules;2 x Parallel 96/128 Cell SunPower Modules Compatibility(Single SKU) *Supports 50Hz operating with extended range (45.2-55.7 Hz) tWhen current limited to 2.66A for 208V or 2.4A for 240V * Chilicon To learn more about Chilicon Power microinverters,call (310)800-1396 or visit chiliccnoower.corn /lr IRON RIDGE XR Rail Family XR Rail Family The XR Rail Femly offers the strength of a curved rat In three targeted sizes.Each size supports specific design loads,while minimizing material costs.Depending on your location,there is an XR Rail to match. Solar Is Not a Over their lifetime,solar panels experience countless extreme weather events,Not lust the worst storms in years, / - di but the worst storms in 40 years.High winds capable a t __``_� �� r ripping Panels from a root,end snowfalls weighing � - +� , enough to buckle a panel frame. .` rr { �"'—•�—..� • XR Rails are the structural backbone preventing ' - rt fat7. { these results,They resist upNtt,protect j( 1{ + + XRIO XR100 XRI000 against buckling and safely and efficiently f`. r" + 1 %Rto Is Mac mw.proee mePMre moone Pe James residential xer000 b e heavyweight aroma transfer loads Into the building structure. } r( ref,designed for regions wins tom a mmudhg r d.s ewoors a rap.a sow msmans alb.ae bait m hers. r/ no arm..hed,leees Wens w m 6 met one end snow ram/dank whin also abase climates and spans up ia IS Their superiorsfwe spanning attachments, capability - '' f• or 1 . 1 • � Mee r.melnmg light end,xmomiml. m.dmmne spans up m 10 me. bear cammodel application requires fewer roof attachments, ° , . .. f 1 . }..~ r t •IV cW.GM • 1a spanning oeneblan • SS'spanning nsPeMaY reducing the number a roof * * • Extreme iced c.peemb • Moderate bad moaned • Corers beack c.nadit oenetredontime,eamount - � :, S • inborn'esdtaMbable • Mena spasm mono)aa.n • Clew encasedclose Anbh of installation time. * • inborn'epmw available ' Mensal Wm..evdleds • Marne Wew.wlmas w� i Rail Selection 41 The table below was prepared in compliance with applicable englneedng codes and standards.*Values are based on the following criteria:ASCE 7.18,Gable Roof Flush Mount,Roof Zones 1 a 2e,Exposure a,Roof Slope of 8 to 20 degrees and Mean Building Height of 30 ft.Visit IronRidga.mm for detailed certification letters. Load Snow(PS9 Wind(MPH) 4' S 4" a' a' tat' NW BO :: Force-BLbdWng Curve . Sloped mWe gamma bah vernal end Weal 4 120 I law m mamatq reW w e ban oeu eNone to°bendeandmMist the awed same aXIS roe. 140 RHO XRtog XR1000 'ei• Medan dewed to Mame strengthen bah ar.atlam out.ralsae theas Waft.fhb wick tad bstureenwm preatnteoet1•hnll ma and a lager system laetrne. BO ¢/1 r maw 1..' 120 20 140 180 80 180 CompetIDlo bath FIR&Mahal Raofe I f Connclomwr>�ed Matedslo BO anR.Nere IseRaMe . MORRdmen made aedtosermtIli 40 rs angella*tth step argil log r .mmhum alb/,awn pranmdwa,an MMWaed tool ne as M soaked Ankh Anodising DreeeM e„r.0 80Mill - — .S L11J ogler pl�M real LLL! and encent ed.mmHN corrosion.whim am providing WMmnb. sanalgae. a eweeNeRve P/Plmep.. 120 16D -- rAK� Tech Brief ZA66.IRONRIDGE UFO Family of Components System Diagram Simplified Grounding for Every Application Ell 0 ___m__:0 0 • 4 B The UFO family of components eliminates the need for - ---Aminomum separate grounding hardware by bonding solar modules ,Amessms isimmolim directly to IronRidge XR Rails.All system types that feature the UFO family—Flush Mount,Tilt Mount and Ground Mount—are fully listed to the UL 2703 standard. : 4 0 o__"m___o 0 4 _ UFO hardware forms secure electrical bonds with both the module and the rail,resulting In many parallel grounding paths throughout the system.This leads to safer and more reliable installations, p 0 o===m:::0 0 • 4 111111 ow Stopper Sleeve Universal Fastening Object(UFO) The Stopper Sleeve snaps The UFO securely bonds solar modules to XFI onto the UFO, n p. q II Into Raps.It co mes assembled and lubricated,and a bonded end Cli amp. can In a wide range of module heights. p , 0 o___m_"_O 1 -' 0 UFO /Stopper Sleeve •Grounding Lug m BOSS"Splice --�--Ground Wire . _: Q Approved Enphase microinverters can provide equipment grounding of IronRidge syrtema,eliminating the need for grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the i - / same rail and connected to the same Engage cable is required.Refer to installation manuals for additional details. • UL Certification Cross-System Compatibility 'V r Y c4,ya Feature Flush Mount Tilt Mount Ground Mount / The IronRidge Flush Mount,Tilt Mount,and Ground Mount XR Rags .1 XR100&XR1000 BOSS"'Splice Systems have been listed to UL .........,. Bonded Structural Splice 2703 by Intertek Group plc. UFO/Stopper d s/ K Cenname tells with bulheln :o bonding teeth.No tope a a ' UL 2703 is the standard for BOSS",Splice d N/A hardware needed. / evaluating solar mounting Grounding Lugs i per Row i per Row 1 per may systems.It ensures these devices Mlcroleverten will maintain strong electrical and &Power Compatible with most MLPE manufacturers. Grounding Lug Bonded Attachments mechanical connections over Optimizers to system Installation manual. A nmle Grounding tugan extended period of time in 4 canrecw en enure row me bonding bon edechse Fire RatingClass A Class A N/A al Pv modules to the and bonds the Wool w the extreme outdoor environments. grounding conductor. ran.it Is Installed with the s Tested or Evaluated with over 400 Framed Modules name socket as the rear m ma u1ss Refer to installation manuals for a detailed list. system. Q Go to IronRidge.com/UFO ,,2021 Ironardpe.Inc.All n®nts rettervea v s i wow 1-palents.cwn tw parent Poto,matron.version 1.21 ,AL_ Tech Brief Zli& IRONRIDGE FlashVue TM See Your Pilot Holes ing Flashing Forward Large Viewport in flashing -�' FIaslVue makes pilot holes highly We set out to des) n a flashin that Checked all Vlslble,like never before ND more g g I.(nous guesswork on hot roots. .� the boxes:fully waterproof,test and easy to Install _ ` correctly,economical,and strong enough to handle � ; every environmental condition.FlashVue does it all. The optimized flashing design features a large vlewport,for easy alignment with the plot hole.And I r ----' • the GripCap and GripCap+sit snugly in place,so the lag can be driven single-handedly. ..� Solve Roof Undulations `-- Throe-Tier Water Seal,Reimagined FlashVuebsea architecture utilizes three layers 'r 01 protection.The sewport is°leveled 0.90',and Also Available:GripCap`: provides a'metonwlr to the GrlpCap.The OrteCep fully caws the Newport while a seeing washer We know roofs are nolalwa - -� able and layer 0l protecede And EPGM perfectly flat.Gnsgel i Can I weber and lag bok'sedtlxdW"mike sick when undulatlonsgetlnlhe-r , \ a: 111111) '� GrIpCr J f 1 GrtpCep&GripCal» —j w w aP+ y„ The 990°capable Grl r -' s FI°`�' S PCW 12.74' -.. .-- tell)and GdpCepa(9.74'tell)can be placed In any orientation,and provides •`-�`.°-•, `. .,•"`."". `. .__..... -. Yrkan-a'ler easy Installs Push smug mb the Newport,What worrying it will roll awry or rotate whledriving ea leg. —L -. -. Gr'�'• Maven Roof Surfaces>1" .". ( i Trusted Strength&Certification , { ! 0 0.75' I .. ,� Attachment Loading `' •- FlashVue has been tested and rated to support 1161 (Ibs)of uplift and 353(ibs)of lateral load. - Structural Certification �� ` Designed and certified for compliance with the International Building Code&ASCE/SEI-7. Large Vlewport in flashing Water Seal Ratings Inlertek ..... -...-_ *report large wport makes easy ro mperAmnedw algn the flashhpwith the puothole,and ® g Passed both theUL441Section27"Rain Test"and TAS100-95°Wind Driven Rain Test"byIntertek. Protect the Rant" drive the lag cantered Into the rafter.The ° elevated ten not only pavan a sturdy © UL 2703 Listed System Lit.2703 441(27) dock for the GrpCep or GdpCap.,but TAs I03(A)-95 !romanwslertheddmg capabilities Conforms to UL 2703 mechanical and bonding requirements.See Flush Mount Manual for more info. '. _ , i, .. , 0Nta lmnnedee.Inc.Al nphn mxervW.11011 www.ImmWgn.cam er.11l-eaaa7-%O rr mom Momwrbn.Yammn 1.0 ,A+_