Loading...
Permit RECEIVED City of Tigard AUG 14 2023 Building Division CITY OF TIGARD 13125 SW Hall Blvd, Tigard, OR 97223 BUILDING DIVISION Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 15761 SW 82nd Ave, Tigard, Oregon, 97224 City: Zip: Owner's Name: Patrick Collins Date: 08 / 11 / 2023 Contractor's Name: BRS Field Ops, LLC CCB #: 227185 Design Parameters of the Property/Structure If"Yes", does not Is the installation qualify for the Flood Hazard Located in a flood ❑ Yes prescriptive path, follow Area plain/flood way? E No OSSC or ORSC for design requirements. Is the wind exposure Yes If"Yes", qualifies for Wind Exposure "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes E Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than © If"Yes", qualifies for Yes the prescriptive path. above ❑ No 1 I:/B uilding/Forms/Photo V oltaic-Checklist02-0 I-11.docx ❑ Yes If"Yes" Is the gauge 26 or less? , qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted If the spacing falls Spacing of Minimum 24 inches solar systems P gclamps? within 24 inches and 60 directlyto inches inches, qualifies for the Maximum 60 inches prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? El Yes the prescriptive path. ❑ No Is the roof decking of WSP min. 1/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof © Yes the prescriptive path. surface. ❑ No 3 I:/Building!Forms/PhotoVoltaic-Checldist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Solar Model Number: REC420AA PURE-R Listing Agency: UL 4 I:/Building/Forms/PhotoVoltaic-Chccklist02-OI-1 I.docx