Loading...
Permit (4) 71 CITY OF TIGARD MASTER PERMIT � " COMMUNITY DEVELOPMENT Permit#: MST2023-00377 f I t N is I) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/10/2023 Parcel: 1 S134AC01200 Jurisdiction: Tigard Site address: 11410 SW IRONWOOD LOOP Subdivision: ENGLEWOOD Lot: 40 Project: Peyton Project Description: Rooftop solar system 9.2 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $22,420.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0 Drywall-Trench Drain: 0 Other Fixtures; 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'l 500 sf: 0 201.400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Roof top solar array 9.2 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: MATTHEWS,AMANDAA GREEN RIDGE SOLAR Required Items and Reports(Conditions) PEYTON,COLE 19450 SW MOHAVE CT 11410 SW IRONWOOD LOOP TUALATIN,OR 97062 TIGARD,OR 97223 PHONE: PHONE: 503-395-1943 FAX: Total Fees: $357.19 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR Qc ..nn1_nA1n ihrry AR okl_nnisi m H nhiain a rnmr of ihn mine nr rlirari ni iaelinne in fll INR by rallinn FM 917 1QA7 nr 1 Ann 119 9R4A Issued By: Permittee Signature: 1 e-e .-tif t c;stc a'1 Call 5 .639.4175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. ' Building Permit Application Checklist One- and Two-Family Dwelling FOR OFFICE USE ONLY Cityof Tigard Received ' _ g Date/By: Permit No.: • 13125 SW Hall Blvd.,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 Associated permits: 24-Hour Inspection Line: 503.639.4175 0 Electrical ❑ Plumbing 0 Mechanical IIu.ARD Internet: www.tigard-or.gov ❑ Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A I Land use actions completed. See jurisdiction criteria for concurrent reviews. 0 0 0 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. 0 ❑ 0 3 Verification of approved plat/lot. 0 ❑ ❑ 4 Fire district approval required. Name of district: 0 0 0 5 Septic system permit or authorization for remodel. Existing system capacity _ _ _ ❑ 0 ❑ 6 Sewer permit. ❑ 0 0 7 Water district approval. 0 0 0 8 Soils report. Must carry original applicable stamp and signature on file or with application. I ❑ 0 El 9 Erosion control 0 plan 0 permit required. Include drainage-way protection,silt fence design and location of catch- 0 ❑ 0 basin protection,etc. 10 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state El ❑ El building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. II Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if El ❑ ❑ there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ El ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, 0 ❑ 0 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- 0 El El floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. 0 ❑ ❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- 0 ❑ 0 prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 0 0 locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 0 0 systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ 0 0 over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. ❑ 0 0 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ ❑ 0 for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or El ❑ ❑ architect licensed in Ore_on and shall be shown to be a.rlicable to the rro ect under review. JURISDICTIONAL SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". 0 0 0 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. 0 0 0 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 0 El 0 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 ❑ ❑ 27 "Drawn to scale"indicates standard architect or engineer scale. 0 0 ❑ 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ ❑ Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, D ❑ 0 and protection measures must be drawn to scale and must include theAtroject arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ ❑ including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. I:ABuildingPermits1BUP-RESPermitApp.doc 02/24/2011 440-4613T(II/02/COMiWEB) Electrical Permit Application RECEIVE FOR OFFICE USE ONLI J City of Tigard AUG 0 3 2023 Received Per446- o Z t 5 7 7 ° 13125 SW Hall Blvd.,Tigard,OR 97223 Plate IMII n Re Plan Review ! iew Phone: 503.718.2439 Fax: 503.598.1960 CITY OF TIGAR(J DateiBy: Related Penni k: TIGARD Inspection Line: 503.639.4175 ' 1 r� DIVISIO �+ Ready Date/By: funs: HI See Page 2 for n Internet: www.tigard-or.gov 3UlLI�ING DIVISIO Notified/Method: Supplemental Information TYPE OF WORK PLAN REVIEW ❑ New construction ❑ Addition/alteration/replacement Please check all that apply(submit 2,ets of plans ss/items checked): ❑Service or feeder 400 amps or more ❑Building over three stories. 0 Demolition 0.Other: Solar Installation 'where the available fault current ❑Manaus and boatyards_ CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts rt 0 Floating buildings. El 1-and 2-family dwelling ❑Commercial/industrial ElAccessory building less to ground,or exceeds 14,OW ❑Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family ❑Master builder ❑Other: ❑Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address:11410 SW Ironwood Loop I00HP or more. ❑"A".`E","1-Y',`I-3", City/State/ZIP:Tigard, OR 97223 ❑Six or more residential units. occupancy. ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldg./apt.#: Project name:Peyton Solar Project 0 Hazardous locations. 0 Supply voltage for more than O Service or feeder 600 amp,or more. 600 volts nominal. Cross street/directions to job site: FEE SC DULE Description Qn'. I Each I Total I " New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 I DESCRIPTION OF WORK Limited energy,residential (with above sq.ft.) 75.00 2 Hookup and installation of 9.2 kW roof mounted solar system Limited energy,multi-family residential(with above sq.ft.) 75.00 2 Renewable Energy 0 See Page 2 l PROPERTY OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation Name:Cole Peyton 200 amps ur less 100.70 2 Address:11410 SW Ironwood Loop 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard, OR 97223 601 amps to 1,000 amps 301.04 2 Phone:( )213-248-2088 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:cmpeyton@gmail.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 I intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature:__ Date: 401 amps to 599 amps 168.54 2 0 APPLICANT ® CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name:Green Ridge Solar above service or feeder fee, each branch circuit 7.42 2 Contact name:Amanda Owen B.Fee for branch circuits without service or feeder fee,first Address:19450 SW Mohave Ct . branch circuit 56.18 2 City/State/ZIP:Tualatin, OR 97062 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( 503)395-1943 Fax: :( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email:permitting@greenridgesolaccom Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:Green Ridge Solar Sign or outline lighting 67.84 2 Address:19450 SW Mohave Ct Signal cif uit(s)or limited energy - ID Signal Page 2 2 panel,alteration,or extension. City/State/ZIP:Tualatin, OR 97062 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:( 503)395-1943 Fax:( ) Investigation t I hr min) 90.00/hr Email:permitting@greenridgesolar.com lndustnal plant(I hr rein) 78.18/hr • Inspections for which no fee is 90.00/hr CCB Lie.:210450 Electrical Lie.:C1490 Suprv.Lie.:6478S specifically listed(i hr min) ELECTRICAL ERMIT FEES Suprv.Electrician signature,required:8a4ar B.Ah.{-:0/ Subtotal: Print name: Brian Butterfield v Date:8/3/2023 ElPlan Review Required(25%o permit fee): State surcharge(12%of permit fee): Authorized signature: a/—. TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Amanda Owen Date:8/3/2023 days after it has been accepted as complete. a Number of inspections allowed per permit. IbBuilding.Permits\ELC_PermitApp_ELR_ERE.doc Rev Ore17/21115 41)-4615T(I 1/65/COMIWEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Description I Qty. I Each I Tntnl * Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 00.70 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 n Garage Door Opener* 50.01 to 100 kva 552.26 2 >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: n O• ther: Each additional inspection is 66.25/hr charged at an hourly(1 hr min) Inspections for which no fee is 9000'hr specifically listed('�hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 a Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems n Boiler Controls n Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation n H• VAC ❑ Instrumentation ❑ Intercom and Paging Systems n Landscape Irrigation Control* n M• edical ❑ Nurse Calls n Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1:\Building'-Permits\ELC_PermitApp_ELR_ERE.dac Rev 06117/21115 RECEIVED City of Tigard AU& 0 3 20Z3 Building Division CITY OF TIGARD ill - . 13125 SW Hall Blvd,Tigard, OR 97223 BUILDING DIVISION Phone: 503.718.2439 Fax: 503.598.1960 T I GARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 11410 SW Ironwood Loop City: Tigard Zip: 97223 Owner's Name: Cole Peyton Date: 8/3/2023 Contractor's Name: Green Ridge Solar CCB #: 210450 Design Parameters of the Property/Structure If"Yes",does not Flood Hazard Is the installation ID Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Is the wind exposure PI Yes If"Yes", qualifies for Wind Exposure "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less'? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for ❑ Yes the prescriptive path. above ❑ No 1 LBuildmgiForms/FhotoVoltaicChecklist02-01-1 I.docx S Is the construction material wood and does Yes Type of the construction qualify If"Yes", qualifies for Construction as "conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. V Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. El If"Yes",qualifies for Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes with Section 305.4(3)of If"Yes", qualifies for the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ® of composition shingle. Is the roof mounted Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for ElNo the prescriptive path. to the roof framing or blocking directly? 2 I`/Building/Forms/PhotoVoltaic-Checklist02-01-1 1.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of ❑ Yes If"Yes", qualifies for fastener? the prescriptive path. ❑ No Is the roof decking of WSP min. %2" thickness, ❑ Yes decking connected to If"Yes",qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches'? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 C iBuilding/Forms/PhotoVoltaic-Checklist02-0I-I I.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x I I inches. PV Modules Manufacturer:SEG Solar Model Number:SEG-400-BMD-HV Listing Agency:UL 4 I:BuildingiFotms/PhoioV oltaic-Checklist02-01-I 1.docx