Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
Approved plans RECEIVED shall be on job site, ' In 1 4 2023 CITY OF TIGARD GENERAL NOTES 'BUILDING DIVISION AERIAL VIEW 1.INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, VALIDITY OF PERMIT eiy,,,{ `T ..,a. AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING '� 2.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL THE ISSUANCE OF A PERMIT Su nWci circle e „r EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110 BASED ON CONSTRUCTION �A Y � -�- 3.ALL WIRES,INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM - DOCUMENTS AND OTHER •W • 7—` PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 1 4.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL DATA SHALL NOT PREVENT - 44 'i a5. psi -Y 1'.I 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES THE CODE OFFICIAL FROM CONTRACTOR INFORMATION: REQUIRING THE CORRECTION SUNWARD POWER 5.ALL DC WIRES SHALL BE SIZED ACCORDING TO[NEC 690.8] 9182 SE HAMILTON LANE r_, I ( ;. 6.DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH[NEC 690.31] OF ERRORS. ORSC 105.4 HAPPY VALLEY,OR 97086 7.ALLSIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE License#238152 Like(L)re The City of Tigard or,v 'ts STREET VIEW e•'iOIOVi?Q5 a`y ` - " PHOTOVOLTAIC(PV)SYSTEM SPECIFICATIONS CQ .' i3c iOT ci ELECTRICAL EQUIPMENT em}y- F -,-, .r n-33T t3u'n+'�. PV MODULES: 1 yam, (33)SILFAB SIL-400 HC+ - DC SYSTEM SIZE: 13.2 KW DC R • INVERTER(S): OFFICE COPY (17)CHILICON CP-720 INVERTER(S) 1 p' ...: AC SYSTEM SIZE: 12.24 KW AC RACKING SITE INFORMATION RR 9iA :: J fr ONG WANG RACKING:IRON RIDGE XR ATTACHMENT:FLASHVUE 16654 SW AUTUMNVALE LN KKOFFROIAPPLICABLE GOVERNING CODES BEAVERTON,OR 97223 AC SYSTEM SIZE:12.24 KW AC 2021 OREGON ELECTRICAL SPECIALTY CODE(2020 NEC) CITY OF TIGA_?ZD DC SYSTEM SIZE:18a KW DC 2019 OREGON FIRE CODE SHEET INDEX 2019 OREGON STRUCTURAL SPECIALTY CODE LAT,45A26296 2017 OREGON RESIDENTIAL SPECIALTY CODE REVIEWED Fi'-s)� CODE COMPLIANCELONG,.122.B480743 PVO1 COVER (33)SILFAB SIL-400 HC+ PV02 SITE PLAN Approved: [ PV MODULES PV ROOF PLAN PVD4 MOUNTING DETAIL OTC:SITE SPECIFICATIONS [ 7 J (17)CHILICONCP-720INVERTER(S) PV05 LINE DIAGRAM OCCUPANCY:R-3 ` /J /�G�C� PV06 ELECTRICAL CALLS ZONING:RESIDENTIAL Permit#: rAJI 1 (�O�/--/O�OI J 6 \ M (/' PV09 LABELS Address: 1VL� SV f A014--/)wino�'C"� `''N PV08 PLACARD I ,_ PORTtANO GENERAL ELECTRIC PV09 SITE PHOTOS Suite #: ' DRAWN BY:SoIoCAD 4.'3 {.� ' By: Date: /c' 2S 7/26/2023 " COVER-PV01 s END CLAMP MID CLAMP © GO PVMODULE _ MODULE FRAME ( ! ///- PVo RAIL RAIL RAIL _...• _f T / t /irn. / r w- a-1-r ii MAX SPAN MAX. O END CLAMP DETAILS O MID CLAMP DETAILS FRONT VIEW (E)RAF ER roP CHORDS ' CONTRACTOR INFORMATION: SUNWARD POWER 1 9182 SE HAMILTON LANE PV MODULE HAPPY VALLEY,OR 97086 License#238152 RAIL RAIL , .�. ATTACHMENT w� (E)COMP SHINGLE ROOF(1 LAYER) 10"MIN- :B 1i 1-4= / MAX 10"MIN- �1=_. 2'-8"MIN- 1��.� ATTACHMENT 3'-10"MAX MAX (E)RAFTER/TOP CHORD FLASHING(SEE DATASHEET FOR DETAILS) I 2'4"MIN• ^ SITE INFORMATION 5/16"STAINLESS STEEL LAG BOLT 3'-10"MAX QING WAND WLTH 2.1/2"MIN.EMBEDMENT (PER MANUFACTURER) 16654 SW AUTUMNVALE LN _— (E)RAFTER/ BEAVERTON,OR 97223 'fOP CHORD AC SYSTEM SIZE:12.24 ION AC O DETAIL, MOUNTING AND FLASHING DC SYSTEM SIZE:13.2 KW DC 3 SIDE VIEW LAT,45426296 LONG,-122.8460743 (33)SILFAB SIL-400 HC+ PV MODULES _--- ___ (17)CHIUCON CP•720 INVERTERS) EQUIPMENT INFORMATION: ROOF INFO: PHOTOVOLTAIC ARRAY STRUCTURAL CRITERIA RACKING MANUFACTURER: IRONRIDGE ROOF TYPE: ASPHALT SHINGLE PV MODULE COUNT: 33 RACKING PART NUMBER: )(a ROOF FRAMING: MANUFACTURED TRUSS ARRAY AREA: MODULE COUNT•21.34 Fr=704.22 l PORTLAND GENERAL ELECTRIC , ATTACHMENTS FLASHVUE RAFTER/TOP CHORD SIZE: 2x4 ROOF AREA: 9038 FIT , ATTACHMENT QTY: 139 RAFTER/TOP CHORD SPACING: 24" PERCENT OF ROOF COVERED: 1396 DRAWN BY:SOIOCAD SPLICE QTY: 10 ATTACHMENT SPACING: 48" ARRAY WEIGHT: MODULE COUNT"47LBS=1551LB$ MIDCLAMP QTY: 32 POINT LOAD: ARRAY LBS/ATTACHMENTS=11.16 7/26/2023 ENDCLAMP QTY: 68 DISTRIBUTED LOAD:(Ibs/R") ARRAY WEIGHT/AREA•2.2 LBS/Fr MOUNTING DETAIL-PV04 • SILFM SIL40011CI SPECS CHILICON CP•T20 SPECS EQUIPMENT SCHEDULE CONDUIT A CONDUCTOR SCHEDULE POWERMM(PMAEI: 400W WAIN INPUTVDATAGE: 120v TYPE CM DESCRIPTION RATING TAG OTT WIRE GAUGE DESCRIPTION CONDUIT WE OPEN ORCUITYOLTAGE WOCI: 4102 V REAM DC SNORT CIRCUIT CURRENT: 13.SA MODULES: (RE) SIVAS SIL400 HG WOW (2) 12.2 N-WIRE,UEE.2 COPPER.01,12) MIS POWER-POINT CURRENT IMP): 11.10A MAMA(OUTPUT POWER: 720w INVERTERS: Ill) CNIUCON CP-720 720W 1 (1) 8AWG BARE COPPER.(GROUND) N/A•FREE AIR MU VOWS-PONT VOLTAGE(VW: ERAS V MAXIMUM OUTPUT CURRENT: 3A AC DISCONNECT(S): (1) TN AC DISCONNECT,240V,2-POLE + 10oA 2 (2) 10AWG TNHN/THWN.2 COPPER.(II,ES) S SHORT CIRCUIT CURRENT((SC): 11.51 M.A NO OUTPUTVVITATN: 2WV AC CONDOM: (11 N AC COMBINER 1WA (1) 10 AWG THWN-2 COPPER.(GROUND) 9/A•EMi SERIES FUSE RATING: SW KW UNITS PER 30A CMCWT: R 3 (RI 10 AWG THHN/TNWN.2 COPPER-(L1,ES) 1-PHASE,EOM UL 1741 LISTED (1) 10AWG THWN-2 COPPER-(GROUND) 1/4"EMi (3) A AWG THWN.2 COPPER-(Li,L2,NEUTRAL) 4 (1) IAWS THN.SCOEt.(GROUND) 1^EMi W PP ROOFTOP TO COMBINER PANEL CONTRACTOR INFORMATION: L•70 FTIONE-WAY) , SUNWARD POWER a•1.21 OHMS/1000FT 9182 SE HAMILTON LANE 1=3 A(PER MICRO INVERTER) HAPPY VALLEY,OR 97086 OPERATING VOLTAGE=240V License#238152 STRING VOLTAGE DROP = V(DROP)=(1•2L•R) = 202.700.00121 ROOFTOP TO COMBINER PANEL:=1.69% 4.07 V COMBINER PANEL TO INTERCONNECTION:=0.2% COMBINED AC VOLTAGE DROP:1.89%<2% _ %V=V(DROP)/OPERATING VOLTAGE STRING I3):1 MODULES a 4,07/240 = 1.69% 'SUPPLY SIDE CONNECTION. =- I I I NEC 130.46,NEC 230.79B NEC n 705.11 I`IA 11NYFRlERs ¢ r (N1 SOW 10,120/240 VAC L AC COMBINER ADSONL (EI 200A MAIN SERVICE PANEL TOVTUT SRID L -- SOLAR y , UL 1741 COMPLWNT NAC DISCONNECT SIRING(E):14 MODULES /� NE SR /1 SOW FUSED, V 1`3!1 VISIBLE,FSED, (E)2WA1P -- ) UBEIFD,OPEN \ 0 4 IMMI ICI 1 1•-- MOV,2-POLE -, IS INVERTERS /1 L_ L _� t____� A IN)70AFUSES :11(EItOADS SITE INFORMATION STING li MODULES I I 11 --_NEMA�%R 2 I L � DING WANG O)30A-iP N II � = ® 76654 SW AUTUMNVALE LN IE_I i L.-J i—J-. _—-L-_— _ ____ _ BEAVERTON,OR 97223 ,�4111A B INVERTERS 1� , - �-, 1 Y I N (J,` _ AC SYSTEM SIZE:12.24%W AC L- J F _—_yyyl —___ _______ 1 4 4 1 _ DC SYSTEM SIZE: 13.1 KW DC ANEMA 3R NEMA 3R I AT,45.426296 1 }BO% 2 1H10% 3 I- -I G] 1 COMBINER PANEL TO INTERCONNECTION -( 80743 � LONG,AB SIL- L•15 FT(ONE-WAY) IE) GROUNDING/I LEI UTRITY METER (33)SILFIL•400 HG R=0.308 OHMS/1.000FT ELECTRODE I PV MODULES I=51 A .- (17)CHIUCON CP-720 INVERTER(S) OPERATING VOLTAGE=240V COMBINER PANEL TO INTERCONNECTION VOLTAGE DROP = V(DROP)=(I•2L•R) • 51'2'15'O.000BD8 PORTLAND GENERAL ELECTRIC = 0.47 V 1 a %V=V(DROP)/OPERATING VOLTAGE VISIBLE,LOCKABLE, DRAWN BY:SolaCAD • 0.47/240 LABELED AC DISCONNECT = 0.2% LOCATED WITHIN 10' 7/26/2023 OF UTILITY METER LINE DIAGRAM-PV05 STRING CALCULATIONS SYSTEM OCPD CALCULATIONS Chilimn CP-720 STRING#1 STRING#2 STRING#3 INVERTER MODEL(S): CNIEICON CP-720 MAX AC CURRENT: 24.00A 24.00A 3.O0A 4 OF INVERTERS: 17 MICRO INVERTERS IN SERIES 8 8 1 MAX OUTPUT CURRENT: 3A NOMINAL STRING VOLTAGE: 24EV 240V 240V (POE INVERTERS)X(MAX OUTPUT CURRENT)X 125%<=OCPO RATING - MAXACOUTPUTPOWER 5760W 5760W 720W (17X3AX 125)=63.]SA 4=70A,OK , ARRAY DC POWER: 13200W TOTAL MAX AC CURRENT: 51.00A SUPPLY SIDE INTERCONNECTION MAIN BUSEAR RATING: 200A NUMBER OF CURRENT CARRYING CONDUCTORS PERCENT OF VALUES MAIN DISCONNECT RATING: 200A 4-6 .80 PVOCPD RATING: 70A CONTRACTOR INFORMATION: 7-9 .70 SERVICE RATING =PV OCPD SUNWARD POWER 10.20 SO 200A5=70A OR 9182 SE HAMILTON LANE CONDUIT&CONDUCTOR SCHEDULE HAPPY VALLEY,OR 97088 TAG CITY WIRE GAUGE DESCRIPTION CONDUIT SIZE CONDUCTOR RATING CONDUCTOR TEMP.RATE AMBIENT TEMP TEMP.OR #OFCONDUCTORS CONDUCTOR RATING CONDUIT FILL License#238152 ER DONATE W/DERATES 1 (2) i PV-WIRE,USE-2 -(L1,L2) N/A-FREE AIR RR 90'C 32°C 0.96 N/A-FREE AIR 28,8A N/A-FREE AIR (1) 6AWG BARE COPPER-(GROUNGROUND) 2 (2) 10 AWG THHN/fHWN-2 COPPER-(Ll,L2) 3/4"EMT 40A 90°C 32°C 0.96 1 38,4A 11.9% (1) 10AWG THWN-2 COPPER-(GROUND) 3 (6) 10 AWG THHNNHWN-2 COPPER-ILLL21 3/4"EMT 40A 90°C 32°C 0.96 0.8 30J2A 27.6% (1) 10 AWG THWN-2 COPPER-(GROUND) 4 (3) 4 AWG THWN-2 COPPER-(L1,L2,NEUTRAL) 3''EMT 89A JS'C 32'[ 0.96 I 79.9A 32.9% (I) 8AWG THWN-2 COPPER-(GROUND) SITE INFORMATION QING WANG 16654 SW AUTUMNVALE LN BEAVERTON,OR 97223 AC SYSTEM SIZE:12.24 KW AC DC SYSTEM SIZE: 13.2 KW DC LAT,45.926296 LONG,-122.8480743 (33)SILFAR SIL-400 NC. GROUNDING&GENERAL NOTES: INTERCONNECTION NOTES: PV MODULES 1. PV INVERTER IS UNGROUNDED,TRANSFORMER-LESS TYPE. 1. GROUND FAULT PROTECTION IN ACCORDANCE WITH[NEC 215.9]&[NEC 230.951 (17)CHILICON CP-720 INVERTERS) 2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE 2,SUPPLY SIDE INTERCONNECTION ACCORDING TO [NEC 705.11]WITH SERVICE ENTRANCE CONDUCTORS IN • 3.ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE ACCORDANCE WITH)NEC 240.21] INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. 4.JUNCTION BOX QUANTITIES,AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD- DISCONNECT NOTES: PORTLAND GENERAL ELECTRIC JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS S.AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS) DRAWN BY:SoloCAD AC DISCONNECTING MEANS IS LOCATED WITHIN 10'OF SERVICE DISCONNECT. 2,AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE LOCKABLE,AND BE A . • VISIBLE-BREAK SWITCH. 712612023 3. FUSED AC DISCONNECT TO BE USED. ELECTRICAL CALCS-PV06 LT MAIN PHOTOVOLTAIC LABEL( PHOTOVOLTAIC AC DISCONNECT LABEL PLACED ON THE MAIN DISCONNECTING MEANS FOR THE PV F, Qro AT AC DISCONNECTING MEANS. SYSTEM DISCONNECT 1EC690.13031I RATED AC OUTPUT CURRENT: ® DLEC690.541 NOMINAL OPERATING AC VOLTAGE: p LABEL 7 5 U Cr WAR TlT ECT-CURRENT EXPOSED RACEWAYS,CABLE TRAYS,COVERS AND PHOTOVOLTAIC POWER SOURCE ENUOSORLS Of JUNCNON BOXES,MID OTHER WIRING METHODS:SPACED AT MAXIMUM 10FTSECTION OR WHERE SEPARATED BY ENCLOSURES,WALLS, P LABEL MEANS WHERE THE UNE AND PARTITIONS,CEIUNGS,OR FLOORS. ELECTRIC SHOCK HAZARD LOADTERMINALS MAY BE ENERGIZED IN THE OPEN (NECBOD31(D)R)] POsm90. SOLAR PV SYSTEM EQUIPPED CONTRACTOR INFORMATION: TERMINALS ON THE LINE AND (NECTICS.31B]] LOAD SIDES MAY BE ENERGIZED WITH RAPID SHUTDOWN LABELS SUNWARD POWER PD'IZp'3VSTEM5TIHAT SHUT DOWN THE ARRAY AND CONDUCTORS9182 SE HAMILTON LANE IN THE OPEN POSITION LEAVING THE ARRAY: _ SIGN TOBE LOCATED ONORNO MORE THAN 3FT AWAY FROM HAPPY VALLEY,OR 97086 TURN RAPID SHUTDOWN SERVICE DISCONNECTING MEANS TO WHICH THE PV 5T5 ISMS ARE S'MCH TO THE"OFF' .J CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED License#238152 POSITION TO SHUT DOWN RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. (NEC 690.561CI111] AWARNING LABELS PLACED ADJACENT TO THE BACK-FED BREAKER FROM PV SYSTEM AND REDUCEN POWER SOURCE OUTFUT CONNECTION. THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE SHK HZRD IN ARRAY CONNECTION TO RUSBAR. NOT RELOCATE THIS OVERCURRENT DEVICE( INEC 7O5,12(9)13)(211 ACAUTION IABEESON EQUIPUSMT CONTAINING OVEPNRREN RAPID SHUTDOWN LABEl9 DEVICES IN CIRCUITS SUPPLYING POWER TO SIGN LOCATED ON 00.NO MORE THAN SET MULTIPLE SOURCES OF POWER A MBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SWITCH FOR FROM INITIATION DEVICE SOURCES (NEC 6B0.56(CN2)I. INEC705.101 SOLAR PV SYSTEM / • \ WARNING BEL 5 EQUIPMENT CONTAINING DVERCURRENT THIS EQUIPMENT IS FED BY MULTIPLE DEVICES IN aRCURS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPUED FROM SOURCES.TOTAL RATING OF ALL MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES.INEC SITE INFORMATION OVERCURRENT DEVICES,EXCLUDING 705.12(IIRI(311 MAIN SUPPLY OVERCURRENT CLING WANG DEVICE,SHALL NOT EXCEED 16654 SW AUTUMNVALE LN AMPACITY OF BUSBAR. BEAVERTON,OR 97223 AC SYSTEM SIZE:12.24 KW AC DC SYSTEM SIZE:13.2 KW DC LABELING DIAGRAM: MAIN SERVICE PANEL LAT,45.426296 0 LONG,-122.8480743 PH COMBINER EXISTING NG SUB PANEL (33)SILFAB SIL-400 HCR SUBPANEL-IF USED TO (ONLY IF WHERE POINT O PV MODULES COMBINE PV OUTPUT OF INTERCONNECTION CIRCUITS OR INVERTER AC DISCONNECT IS MADE' O v (17)CXILICON CP-720 INVERTER(5) JUNCTION 80% O ® O O O O (II) 0 O O O O _ LABELING NOTES: �--- 1, LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO DETERMINE 0 PORTLAND GENERAL ELECTRIC EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES MID MAKE APPROPRIATE O © O O ADJUSTMENTS. 10111.Y6N ONLY IF PY 2. LABELING BASED ON THE 2020 NATIONAL ELECTRIC CODE,OSHA STANDARD CR95911RITgD WNSISTSCR LOAD DRAWN BY-SDIOCAD 19ATERIAL ASEDOANSI 35. COMM ER)LaA CONSISTS WWII 3. MATERIAL BASED ON THE REQUIREMENTS OF TIE AUTHORITY HAVING JURISDICTION. SIN RR6u04 9Yf RRFARkPI 4 LABELS TO BE OF SUFFIOENTDURAMLITYTO WITHSTAND THE ENVIRONMENT INVOLVED(NEC 7/26/2023 1101211 •• ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABEUNG PURPOSES ONLY.NOT AN ACTUAL REPRESENATION OF 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/11%WHITE ON RED BACKGROUND:REFLECTIVE,AND EQUIPMENT AND CONNECTIONS TO BE INSTALLED.LABEL LOCATIONS PRESENTED MAY VERY DEPENDING ON TYPE OF LABELS-PV07 PERMANENTLY AFFIXED]NEC 690.31(11)(2)) INTERCONNECTION METHOD AND LOCATION PRESENTED ELECTRICAL DIAGRAM PAGE. " • r CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS AS SHOWN: " CONTRACTOR INFORMATION: av SUNWARD POWER FRONT OF HOME 9182 SE HAMILTON LANE HAPPY VALLEY,OR 97086 COMBINER License#238152 OR RAPID SHUTDOWN AC Om Ilh7fCDISCONNECT SWITCH MAIN DISTRIBUTION ''II UTILITY DISCONNECT ,'LD• JI I 41 PV ARRAY ' MI ' IN--I JNEE MIEN SITE INFORMATION QI WANG NG 16654 SWW AUTUMNVALE LN BEAVERTON,OR 97223 AC SYSTEM SIZE;12.24 KW AC 16654 Sw Autumnvale Ln,Beaverton OR 97223 DC SYSTEM SIZE.13.2 KW DC LAT,45 426296 LONG,-122.8480743 DIRECTORY: 33)6V MODUL ES NC P PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION (17)CHjucON CP-720 INVERTERS) OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM. (ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED PORTLAND GENERAL ELECTRIC WITHIN: NEC 690.56(B)&(C), [NEC 705.10] DRAWN BY:SoloCAD 7/26/2023 PLACARD-PVOB • SITE PHOTOS: iI.i Oil iC I l 6-,,, \,\,\‘ IV 1 , q I IQ , I. i% F~ , Imo`_1 Fw Nn CONTRACTOR INFORMATION: a4 _ �I 6AR SUNWARD POWER ale , . wq ` 1{U t -Frees E0, YE HAMILTOR 9ANE 708 o:nov'Al{,�pu¢8 nu 1 " / _ Dtd e HAPPY VALLEY,OR 97086 I kd+.eI TO, I IN k Kill •:;'•� '�GF- FAt- '., Tee d' I d , APP .' License#238152 Portland General Electric a RtfhlYfl11,�NIiWCif b.s« A I « �,' III iC x IN.@AI§91411... , VA - a - NAIL-1 -., + SITE INFORMATION jailill "O" tas � � gING WANG i ,.., At `I ilk, 16654 SW AUTUMNVALE LN r arty :,tl. 1,'�, BEAVERTON,OR 97223 AC SYSTEM SIZE:1224 KW AN r ,.. . DC SYSTEM SIZE:13,2 KW DC LAT,45A26296 .."�.yyam�..�, .. r7 ';+1 LONG,-1228480743 � W ..1....7., ' (33)SILFAB SIL-400 11C+ -,-- PV MODULES (17)CHILICON CP 720 INVERTER(S) iyO. ! 1 . PORTLAND GENERAL ELECTRIC •` 'Ed DRAWN BY:SoIoCAD , i 7/26/2023 SITE PHOTOS-PV09 S • ELECTRICAL.n[Ir14T+OME NO Tea MNpwa SIC NOM Wd.I.Pi.n 1pmul Wp IA rim • •%. A.A.,.Pr..wWY Npmw u SSA a .00 E. Nompmpp..amltuwpw we uo • OP.Mwlmlh.MN • NM S I L FA B • M•'mnnm. Mr :A 5 O L SOLAR' "°°'Y"'°.nIT • 'aw LA Mml.wnmhn.plYn AU v lom slllooNo- Ehbrwtly A m uw•Ama Wp oT.N a.m.eadtSW 9210W W+,'.wu.hllpw.•UT.61%14w,51.'.0/41•.ar..ImlWa••N9N sun en/ow erman nl mw.uluhnnnnuehaww eaWwl.Mmmvw Wdaw pawl.110,101. MEauIRu1PMONRTME,0311AO NN ' anafc (Minn MW*I...•liftI 9Lapclp nhm.m NmmtlonM,L.EI Ina mm.1a l.namm ISJU Ntln,1STN MwmumrRalme l+.'n4+m.; WM1o0Md AMP.nm[W lWA,IC mar Wfn]t AMMKlN nal Pun/ultw , RAS A.A..a0. •lm0!Ymp* Ads RM IMltm•MnaRm 9 pwN-OatMm• 9hMe LM,USI, 4Y.. LI..e aw mating MMw. �I• I1.mplenROE. antbAsaluowft CWh.M wmmtpnlrtlrulnmlYtbn',ANY LW dubAlinwuumns opnrNIAA. l Mq•0SNn.wI41.NGbangWl Ada*. fludAl�M04 IN� LIIWmMYmtl UV reform WEMMM.YfnMNM Pm. UMW Nwmwn Mb!•1 WYumeex fNbg SAISIINvm•OCMWnS.1YRSN.0Y11 4 JIIMd ammo Amp.,&w 10.30 11llA REAM AMMO.IPMOY• TEMPERATURE WPM WWANTISE rvrPennrereemoenle wu4Lyc MON1.pmEua.nlmeMbal.IW Aye." isr,enaCNRnem VCe OA WC ,Lear powA•:Iumn¢gum!. Myron Irput.re CaMaerl Pms OJS%PC .9e.L%xAI0l„VT d bat OULUII TO ,,,,SYIMmdle -.VA, arpenUIsW •PSW.M%MT Mil PIGfOMS SIMPMMO NECE ULnn6L011 Ed rnRI.a14tlal,Ed1^.0.E11304..1ova m.ULMil6 ypplh,p, ,,M1[.Almm.l UPI/ill^..ASAYIPOSIAIAMS0.7...,CAQUIPSIMUOIS Mr". N AL.a !SG MT-U=Hir'.MCn tualmuN^..6n130+aaN1'^.Et 1nn19MEWT-AtaleTtb aWRlOCmaIm1.14tlfa931Wm.a PWTrvd YnnlC.IV.i.l CwaMA Ul Fn R.OM TM.P.aC IIET' P.An MJSaIMa NIdle?. 0* COwt 0000mly �Ma^h'LsS tl.Rlne MnpMbr glmaA.Wm A•••••.rNN•M.MImLY - amume.hna pump. byeepundoslmwwaaw. Ileatua.m MM.MwnpO4.M pnMNmwuYO•n.. M.YOMb•F,Ibnnuaole..mb .-cel e...MOC YIgn Rya L.mroe.Ml..Pu.lemMNv A < mslvl1ENq 7� 4 r ,Ear 1,12i1301114 +Ear pnN.y_, RELIABLE ENERGY. I' 1 saFAe SOLAR INC. DIRECT FROM THE SOURCE. Or—m MIS A IVO USA T.I 31LLE604TS1 ea g to outpe orm. MM..MaelmMm Dependable,durable,high-performance S ,Lro w m„P. solar panels engineered for North +wnaWM U \4 ` ' $1 American homeowners. f'I .�4: \' - / $ ),a G,,,lryp„LPIw En, g� WMN.W NOT SO Canada SILFABSOLAR.COM y �IIGGyS@@ car mur V•190SAU L CMER LMIaI ill `M4..1.4C+MMaM Rl.aEl i + ..••Ih•.m.r ...r mrwMm.rw. %% • k e ........'....a........ L_u_Ph 81""I L R EV720.20.01 II. CMllcon Power Microinvertara I L II CP-720.60/72/96-208/240-MC4 Microlmerter Specifications CHILICON POWER CP-720 INPUT DATA(DC) Dual Panel Microinverter Recommended Input power(STC) (190-420 WI x2;(380-840W)it tww.., Maximum DC input voltage 120 V MPPT voltage tracking range 56-82 V(240V1 48.5-82 V 1208V) Operating range 47-82 V dall: 11 Min./Max.start voltage 44-96V Max.DC input short circuit current 16 A Max.DC Input current 13.5 A Ground fault protection Transformer Isolated 2000 Vrms input/output/chassis OUTPUT DATA(AC) .208V p14ev Max.continuous output power 713 W 720 W Max.continuous output current 3.43 A(can be current limited to 2.66 A) 3.0 A(can be current limited to 2.4 Al Nominal output voltage/range 208/183-229 V 240/211-264 V .,,. Extended output voltage range 133/160/166-250 V 153/173/192-288V Nominal frequency/range 60.0/59.3-60.5 Hz 60.0/59.3-60.5 Hz CP-720TM Series iViicroinverters Performance Extended frequency range 54.22-66.75 Hz' 54.22-6675Hz" •Supports up to 840W with no dipping(or 2e420W) Power factor -0.6 to 0.6 programmable -0.6 to 0.6 programmable The Chilicon CP-720 allows Installers to •Maximizes energy production over life of system Maximum units per 30 A branch circuit 7114 moduks)/9f)16 modules) 8116 modules)/10t(20 modules) maximize PV system production, while •Minimizes losses due to shading and debris Maximum output overcurrent protection 6.3 A Fuse;12A peak for 30 uSec 6.3 A Fuse;124 peak for 30 uSec minimizing Installation and operational •Eliminates single point of failure for system costs. Microlnverter based architectures EFFICIENCY offer the benefit of Increased flexibility In Simplicity •All AC design- CEC weighted efficiency 96.1% panel deployment,while also providing per No string calculations needed •No GEC needed for microinverter panel visibility to simplify system O&M. Peak inverter efficiency 96.7% •Eery Installation with standardized trunk cables With Its all-AC approach, Integrated Static MPPT efficiency(EN 50530) 99.5la-99.8% grounding,modular bus cabling,and ability Versatility Night time power consumption 100mW; Standby Reactive Current<200me to support up to 16 panels on a 30A branch •Compatible with most 60,72,96,125 cell panels MECHANICAL DATA circuit, the CP-720 simplifies both design •single SKU 240V or 208V Ambient temperature range -40° C to e65' C and Installation. Both freq-Watt and volt- •Allows for variable module placement Dimension(W xHxD)including connectors 12•x8-x 1.8' Watt modes allow AC control by off-grid •Robust PLC communication protocol(500 ft range) Weight 3.83 kg(LOlbs) systems. Coupled with Chil(con's CP-100 •Self supply mode(zero-export) gateway and cloud-based monitoring •Supports up to 30A branch circuits Enclosure rating rvEMAs •Up to 20 panels possible on one branch circuit software,the CP-720 can form the energy FEATURES Communication Mesh Networked Power Line(130.2 kHz carder) management backbone of both residential Reliability,Safety,&Compliance MonitoringMonitoring ola CP-100 and commercial PV systems. • p B gateway a62A1.2,CSAnd Online Cloud •NEMA 6 rated construction UL1743,IEEE tad 1547,IEEE tad C62.41.2,CSA C22.2 NO.107.1 •25 year warranty CISPR 22 Class 8;HECO Rule14H(Advanced Inverter),HECO Ride 22(Self-Supply) Certifications e ((/a/'^^♦o •AC branch circuits will not support arc faults Rule 21/UL17415A;Complies with NEC 690.12 Rapid Shutdown C Nl1i) .IC:).. ® •Quick disconnect circuit to mitigate grid Instabilities Product Warranty 25 Years 11�1 •NEC 690.12 rapid shutdown compliant 2 x Series 60/72 Cell Mono or Poly PV modules /MBE Ill USA s^ Mtertek •CA Rule 21(UL 1741.51)compliant 2 x Parallel HV Panasonic Modules;2 x Parallel 96/128 Cell SunPower Modules Compatibility(Single SKIN 'Supports 5011,operating with extended range(45.2-55.7 Hz) tWhen current limited to 2.66A for 208V or 2.44 for 240V Chilicon ^I www.chiliconpower.com Chilicon "l To learn more about ChNkon Power mkxolmertma,xgi a or Alit chBconpowor.uom Ziei IRONRIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail In three targeted sizes.Each size supports specific Solar Is Not Always Sunny design loads,while minimizing material costs.Depending on your location,there is en XR Rail to match. . Over their lifetime,solar panels experience countless ' extreme weather events.Not lust the worst storms in years, but the worst storms in 40 years.High winds capable of ` � /.�' II______..ii_ --=-___...--i.._panels from a roof,and snowfalls weighing - _- i enough to buckle a panel frame. XR Rails are the structural backbone preventing {,_r ' . these results.They resist uplift,protect f ; - XR10 Xa100 XRI000 against buckling and matey and efficiently / *f + transfer loads Into the buildingstructure v r r. `L•• t veto le a sllwk104-raMlemeurao XR1001 ow ultimate residential .Rlw0,Is a lusww.lem.efi y f. 4. 1 rd.rammed for wplmswnh fight or nnrengnla h supports a maps of do'soprano.SO Ws to*to hands Their superior spanning attachments, lily K {{{ ,( ! dam hp t�.l, &are*MS up 1010,weMet also KKaawls&mend spans uplo 12 requires fewer roof attachments, 1 r epWw reducing the number of roof * I • e'awning wader • to rp rpmp.enrompry • 12•spatnlnp ewwny penetrations and the amount ' G : ,� t • aodwr bad oowdldlmm y tu• Heavy b cepabuhr •&drams wed eepsay of Installation time. r'`'- •�', t • Clara aura n eur, • oar a d w a black enodd finish •Clew.roared final, • IreanW solids arefieble • Internal Spices agaKw • Infernal rphod walled* s. Rail Selection OThe table below was prepared in compliance with applicable engineering codes and standards.'Values are 4! �' based on the following criteria.ASCE 7.18,Gable Root Rush Mount,Roof Zones 1 a 2e,Exposure B,Roof Slope of 8 to 20 degrees and Mean Building Height of 30 R Viielt IrooRidge.com for detailed oerdflaetlon letters. � Load Rail Span Snow(PSF) Wind(MPH) 4• 5'4" 6 8' 10' 12' .,L Forty-8t�18zlna cmvw 90 �robrwb Wneum bdh.ativW ntlla d ? a forbeem enda mop roue whbl,anduea them 120 .lid toTM daW shoos of SR Repo NoneNoneye., . ^,r tr < 3 . awash' atrwprb odn 140 Xa10 � �Y*' •'''al w sweadoa E . ',f.. dlraaons while rea am,leong the Is rating rum unique - `S feature trauma grays rarity during during=ba 100 ,•'� "I w.shermd awrew syammlfahrw �"•. 120 ` 20 140 ISO r '' 90 90 Cempetible with Flat It PNohed Roofs Carrodon-Reaetent Nete.eb —___ /,�al�y�: XR Reid fie ImnRldpe Dore MXR Ral4 fie ro�dsdBcbd+enee 40 1 1 r 1 �and %fibres for fie ertrropnsd ar0.kclItzlnu prdMb an �� -'180 _' ! _ mason, ptaenb spasm pitched root Pl had mounting and each mrvdm,while raw pro4eng 50 1e0 ,i?n� esammeale. appbadvr *Mil)amadw rppararo. 120 160 .. m n .. x (1l Io�ongnarnno.a-Ilcop G. Wcol•mwecclM1M.Tu„Itt.m,o• ae•gn9arrr 0 KM inv00 0rnsAs,ipntl rwuve6V,WYwwjp•Mr0tcow wG rdd.'Hl.aan In,mon mlonnadan.Vomon,M ,A�_ 4 y • Tech Brief f IRON RIDGE UFO Family of Components System Diagram Simplified Grounding for Every Application ,00"...°° _ v. The UFO family of components eliminates the need for separate grounding hardware by bonding solar modules directly to IronRidge XR Rails.All system types that feature the UFO family—Flush Mount,Tilt Mount and Ground itiMount—are fully listed to the UL 2703 standard. + •' UFO hardware forms secure electrical bonds with both the ' Q Q___m___Q Q 3 module and the rail,resulting in many parallel grounding paths throughout the system.This leads to safer end more reliable installations. 1 0 Q_--m---Q 0 • I sl Stopper Sleeve Universal Fastening Object(UFO) The stopper Sleeve snaps The UFO securely bonds solar modules to tit onto tits UFO,convening d Into Rails f comes assembled and lubricated,end I a bonded end damp. can fits wide range of module heights -hts. /l_-_®--_Q Q I = 0 UFO 4 Stopper Sleeve •GroundingLug --.1---PP m 130SS"SpliceGround Wire 2 Approved Enphase microinverters can provide equipment grounding of IronRidge systems,eliminating the need for grounding lugs and field installed equipment ground conductors(EGG).A minimum of two microlnveners mounted to the same rail and connected to the same Engage cable is required.Refer to installation manuals for additional details• � -/ ! „ UL Certification Cross-System Compatibility �� - r r,- s� The IronRidge Flush Mount, Feature Flush Mount Tilt Mount Ground Mount Tilt Mount,and Ground Mount BOSS"'Splice � / Systems have been listed to UL XR Retie `� XRtbg&XR1fX18 Bonded Structural spline / 2703 by Intertek Group plc. UFO/Stopper d / +� "" WMade true wall butein 0. oondep team.No tools or �► ' UL 2703 is the standard for BOW~Splice `� V N/A fakware rlaedad. / evaluating solar mounting Grounding Lugs t per Row 1 per Row 1 per Array systems.It ensures these devices 6roundln L will maintain strong electrical and M�&dn Compatible with most MLPE manufacturers. S Power mechanical Connections over Refer to system Installation manual. 4t, A eagle Grounding Lug Bonded Attachments OptbNzers connects an enure row The bonding bon&dachas an extended period of time in of vv modules to me and binds the L-foe to the extreme outdoor environments. Fin Rating Class A Class A N/A grounding conductor. refit Is insisted with the same socket ea the rest of the Tested or Evaluated with over IOC Framed Modules system. O Go to IronRidge.com/UFO ModUbe Refer to installation manuals for a detailed list. ilrk. a Tech Bnef 4 IRON RIDGE FlashVueTM See Your Pilot Holes a II Moving Flashing Forward Large Viewport to Fleshing $i --=* FlashVue makes pilot holes highly .,,. I vsible like never before.No more We set out to design a flashing that checked all tedious guesswork on hut roofs. the boxes:fullyo watmical, of,fast ng a easy to Instal) _-- s+ f \ 4 correctly economical,and strong enough to handle every environmental condPoon.FlashVue does It all. - ! 410 The optimized flashing design features a large I �`"F Al j/ vlewport,for easy alignment with the pilot hole.And /r. '=--; ' , the GdpCap and GripCap+sit snugly in place,so - I !- the lag can be driven single-handedly. i - _ `. Solve Roof Undulations Three-Tier Water Seal,Relmagined Plant/an n see erdi to b re utilizes three layers or arcades The vie fort a elevated 0.80',am Also ICvailBl)Ie:GripCOp+ 11 fullyw the vie Pip rt the arlmo The hePCa k"3',' -�\ = fully lave the Newport whlk•s.aklgWpMr Welnow roofs Grienotatones atlas anther layer or protection.And an EPDM perfectly tint.GdpLep+can helpanther -`-_ wage/antlly borne'the aeel'In the atadc when undulations get in the Piny. .... S OdpCep&OrlpCept Sa .— -.. GdpCap 2„ The p°capable Orlpeap(2.74' �:-..� alpandarlpCep.(8.74'tdllcmbe `7, r) Oland In any onenleaon,and provide a ^ - 'Aktloe for easy Mads.Fishsnug ki �._. 1„ .��,. Into theNe w Newport,without enn'sh It will roil away or rotate Male driving the log. - _.. . . _ neven Roof Surfaces>1" \ Trusted Strength&Certification (,\ m0Th" Attachment Loading FlashVue has been tested and rated to support 1161(Ibs)of uplift and 353(Ibs)of lateral load. -,--- Structural Certification iii Designed and certified for compliance with the International Building Code&ASCESEI-7. Oil Large Vlewport in Flashing Intertek - -. The largevktwport nines easy ® Water Seal Ratings TnWa to align the Cashing with the pin hole.and Passed both the UL 441 Section 27"Rain Tear and TAS 100-95"WInd Driven Rain Test"by Intertek. Plaint the poor dove the leg centered Into the rattan.The elevated rim not only pawned salNy UL 2703,441(27) dock forawaepca or enpCap.,but © UL 2703 Elated System Tas roc(A)-es increases waterahedtng caeblatee Conlorms to UL 2703 mechanical and bonding requirements.See Flush Mount Manual for more info. _: i��_ O20'104mdedae,toe.MKateeree.rv.d wren www.lrenridge.com or oe11l-1100 pl7-9323 for more mformetIon.Version I ,Ak_