Permit (2) CITY OF TIGARDIll
MASTER PERMIT
■ COMMUNITY DEVELOPMENT Permit#: MST2023-00251
T[(,A R,J7 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 06/29/2023
Parcel: 1 S135CD06900
Jurisdiction: Tigard
Site address: 9728 SW LONDON CT
Subdivision: LONDON SQUARE NO.2 Lot: 21
Project: Crandall
Project Description: Rooftop solar system 5.265kW.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $2,811.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckfiw Prevntr: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N
Other: Y Other Description: Roof top solar array 5.265 kW Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
ALT SF VB R-3 0
Owner: Contractor:
CRANDALL,AMY TML INTERNATIONAL LLC Required Items and Reports(Conditions)
9728 SW LONDON CT 6405 E MILL PLAIN BLVD
TIGARD,OR 97223 VANCOUVER,WA 98661
PHONE: PHONE: 800-364-0470
FAX:
Total Fees: $356.19
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
the 180 days. ATTENTION: Oregon law uires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
cc9-not_nevi n then h nna oc,_nn111non n,, ,"nht,in n rnnv of thn nape nr dirnrt ni ipctinnc In(11 INr,by r,Ilinn con 919 10147 nr 1 Ron 119 914d
Issued By: ii Permittee Signature: P 'e e P 1 1 C R "1
Call 50 9.4175 by 7:00 a.m.for the next available Inspection date.
This permit card shall be kept in a conspicuous place on the Job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
•
Building Permit Application
Residential RECEIVED FOR OFFICE USE ONLY
City of Tigard Received • ►
q q 2
114 13I25 SW Hall lvd,Tigard,OR 97223JU N O 5 COLS Date/By:Plan Review 5 ��-3 r Pe 0p DS
� 2
Phone' 503.718.2439 Fax: 503.598.1960 Datealy C( //K Z3 Other Permit:
T I G A R D Inspection Line: 503.639.4175 CITY OF-f'I �+I I.' Date Ready!By: r� Jars Si See Page 2 for
Internet: www.tigard-or.gov nl Ill r11 Ati{ Notified/Method: ra' �O � ��7 Supplemental Information
TYPE OF WORK REQUIRED DATAYI-AND 2-FAMILY DWELLING
0 New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
❑Addition/alteration/replacement ❑t• Other:Solar equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
1-and 2-family dwelling ❑Commercial/industrial Valuation: $2$11.00
❑Accessory building El Multi-familyNumber of bedrooms:
al ❑Master builder ❑Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of Floors:
Job site address:9728 SW London Ct New dwelling area: square feet
City/State/ZIP:Tigard, OR 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name:Solarinstall-ACrandall Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other stnicture area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Lot no.: Permit lees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Installation of 13 solar panels in 2 arrays on a roof-mounted 5.265kW PV System Valuation: S
Existing building area: square feet
New building area: square feet
la PROPERTY OWNER ❑ TENANT Number of stories:
Name:Amy Crandall Type of construction:
Address:9728 SW London Ct Occupancy groups:
City/State/ZIP:Tigard, OR 97223 Existing:
Phone: ( )561-432-8209 Fax:( ) New:
III APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES*
(Please refer Mjee sehedale
Business name:TML International LLC
Structural plan review fee(or deposit):
Contact name:Mary Dinsmore-Smith
FLS plan review fee(if applicable):
Address:6405 E Mill Plain Blvd
Total fees due upon application:
City/State/ZIP:Vancouver,WA 98661
Phone:( )(360)326-0650 Fax: :( ) Amount received:
E-mail:permit@infinityd2d.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Business name:TML International LLC Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:6405 E Mill Plain Blvd Solar Installation Spectally Code checklist.
City/State/ZIP:Vancouver,WA 98661 Permit Fee(includes plan review $180.00
and administrative fees):
Phone: ( )(800)818-0598 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lie.:22360 Total fee due upon application: $201.60
Authorized signature: This permit application expires if a permit is not obtained
Z7LIZee1rtel-a-^ .5 within 180 days after it has been accepted as complete.
Print name *Fee methodology set by Tri-County Building Industry
Mary Dinsmore- ith Date:5/30/2023 Service Board.
I:1Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-46I3T(I 1/02/COM/WEB)
Electrical Permit Application FOR OFFICE USE ONLY
City of Tigard Received
Date/B MILIM
• MENIBEIMI
13125 SW Hall Blvd.,Tigard,OR 97223 Plane Review
Phone: 503.718.2439 Fax: 503.598.1960 Date/B : Related Permit#:
T i GARD Inspection Line: 503.639.4175 Ready Date/By: lurls: El See Page 2 for
Internet: www.tigard-or.gov Notified/Method: Supplemental Information
TYPE OF WORK PLAN REVIEW
❑New construction 0 Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked):
0 Service or feeder 400 amps or more 0 Building over three stories.
❑Demolition ❑i Other:Solar where the available fault current 0 Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
El 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural
amps for
El Multi-family ❑Master builder 0 Other: 0
Fire pump.
otherinstallations. buildings.atio
p mp. ❑Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION 0 Emergency system larger separately derived
❑Addition of new motor load of system
Job#: Job site address:9728 SW London Ct 100HP or more. ❑"A","E","1-2","1-3",
City/State/ZIP:Tigard, OR 97223 ID Six or more residential units, occupancy.
0 Health-care facilities. ❑Recreational vehicle parks.
Suite/bldg./apt.#: Project name:Solarinstall-ACrandall ❑Hazardous locations. ❑Supply voltage for more than
❑Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: FEE SCHEDULE
Description I Qty. I Each I Total I "
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#: Ea.add'l 500 sq.ft.or portion 33.92 1
DESCRIPTION OF WORK Limited energy,residential
( tih above q.ft.) 75.00 2
Installation of 13 solar panels in 2 arrays on a roof-mounted 5.265kW PV System Limitedw ever gys
,multi-family 75.00 2
residential(with above sq.ft.)
Renewable Energy ee Page 2
® PROPERTY OWNER 0 TENANT Services or feeders installation, teration,and/or relocation
Name:Amy Crandall 200 amps or less 100.70 2
Address:9728 SW London Ct 201 amps toao0amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard, OR 97223 601 amps to 1,000 amps 301.04 2
Phone:( )561-432-8209 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email:adall@earthlink.net relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature:Authorized VIA Contract Date: 401 amps to 599 amps 168.54 2
ill APPLICANT CONTACT PERSON Branch circuits-new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name:TML International LLC above service or feeder fee, 7.42 2
each branch circuit
Contact name:Mary Dinsmore-Smith B.Fee for branch circuits without
Address:6405 E Mill Plain Blvd rache ciorfurcuitt fee,first
brannch 56.18 2
b
City/State/ZIP:Vancouver,WA 98661 Each add'l branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:( )(360)326-0650 Fax: :( ) Each manufactured or modular 67.84 2
dwelling,service and/or feeder
Email:permit@infinityd2d.com Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name:TML International LLC Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy Address:6405 E Mill Plain Blvd panel,alteration,or extension. 0 See Page 2 2
City/State/ZIP:Vancouver, WA 98661 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 6625/hr
Phone:( )(800)818-0598 Fax:( ) Investigation(1 hr min) 90.00/hr
Email:permit@inflnityd2d.com Industrial plant(1 hr min) 78.18/hr
•
Inspections for which no fee is 90.00/hr
CCB Lie.:223690 Electrical Lie.:C1556 Suprv.Lie.:6210S specifically listed(1/2hr min)
Suprv.Electrician signature,required:S cott LeDUC . ELECTRICAL PERMIT FEES
Subtotal:
Print name:Scott LeDuc Date:6/6/2023 ❑Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee):
Authorized signature: Z74/1.441294.4.-5fr TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
Print name:Mary Dinsmore mith Date:6/6/2023 days after it has been accepted as complete.
* Number of inspections allowed per permit.
LlBuilding\Permits\ELC_PermitApp_ELR ERE.doc Rev 06/17/2015 440.4615T(11/05/COMM'EB
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Best ripdon I Qty. I Each I Total I "
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
5 kva or less 100.70 2
Check Type of Work Involved:
5.01 to 15 kva 1 133.56 133.56 2
❑ Audio and Stereo Systems* 15.01 to25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50❑ Garage Door Opener* >1 01 to 1 kva 552.26 2
00 kva(fee in accordance 552.26 2
with OAR 918-309-0040)
❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System* Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 6625/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed(Ya hr min)
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES •
Fee for each commercial system: $75.00alowedlerpermt. Page 1):
y ' Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
n Audio and Stereo Systems
Boiler Controls
Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation '
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
n Outdoor Landscape Lighting*
❑ Protective Signaling
n Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:1Building',Perntits\ELC_PernsitApP_ELR_ERE.doe Rev 06/17/2015
RECEIVED
City of Tigard JUN 0 5 2023
Building Division BUI DIITYNG IF V SIARON
• - 13125 SW Hall Blvd,Tigard, OR 97223
Phone: 503.718.2439 Fax: 503.598.1960
TI G A R❑ Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address:9728 SW London Ct
City: Tigard Zip: 97223
Owner's Name:Amy Crandall Date: 5/30/2023
Contractor's Name:TML International LLC dba Infinity Solar CCB #: 223690
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? ❑■ No OSSC or ORSC for
design requirements.
Is the wind exposure Yes If"Yes"
Wind Exposure p , qualifies for
"C" or less? ❑ No the prescriptive path.
Installations on detached is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ❑■ Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
❑ Yes the prescriptive path.
above
❑ No
1
I:/Building/Forms/PhotoVoftaic-Checklist02-0I-I I docx
f !
Is the construction
material wood and does 0 Yes
Type of If"Yes", qualifies for
Construction the construction qualify ❑ No the prescriptive path.
as "conventional light
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ❑ Yes If"Yes", qualifies for
the prescriptive path.
❑■ No
Roof framing
members is the spacing 24 inches
or less?
Nominal lumber. Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Is the combined weight It Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance ❑■ Yes
If"Yes", qualifies for
with Section 305.4(3) of ❑ No the prescriptive path.
the 2010 Oregon Solar
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
■❑ of composition
shingle.
Is the roof mounted El Yes
Connections of solar assembly
the solar assembly connected to roof No If"Yes",prescriptiveqp path.for
to the roof framing or blocking ❑ the
directly?
2
F lBuilding/Forms/Photo Voltaic-Checkl ist02-0I-I I.docx
r �
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less?
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
El Yes
"Yes", qualifies for
Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directl to inches inches, qualifies for the
Y Maximum 60 inches
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum #10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? El Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. V2'thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof ❑� Yes the prescriptive path.
surface. El No
3
I/Building/Forms/PhotoVoltaic-Checklist02-0I-I l docx
1 `
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size,type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer:ZN S H IN E
Model Number:ZXM7-SH 1 08-405M
Listing Agency: UL 61730
4
1/Building/Forms/PhotoVoltaic-Checklist02-0I-1 l.docx