Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit
1111 CITY OF TIGARD MASTER PERMIT R a Permit : MST2023-00165 COMMUNITY DEVELOPMENT Date Issued: 08/09/2023 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S1060003301 Jurisdiction: Tigard Site address: 13655 SW 165TH AVE Subdivision: RIVER TERRACE TOWN CENTER Lot: Project: River Terrace Town Center, Lot 76 Project Description: New detached dwelling. NO FINAL INSPECTION UNTIL DEFERRED SDC FEES HAVE BEEN PAID. BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 4 First: 1173 sf Basement: 112 sf Left: 3 Parking Spaces: 0 Height: 29 Bathrooms: 3 Second: 1184 sf Garage: 502 sf Front: 12 Smoke Yes Dwelling Units: 1 Third: 0 sf Right: 3 Detectors: Total: 2469 sf Value: $402,833.89 Rear: 3 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 5 Dishwashers; 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Drains: 0 Storm Sewer: 100 Tubs/Showers: 3 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bcktlw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 5 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Fum<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add.'500 sf: 4 201-400 amp: 0 201-400 amp: 0 W/0 Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SF VB R-3 2469 Owner: Contractor: AG EHC II(NWHM)MULTI STATE 2 LLC TNHC OREGON LLC Required hems and Reports(Conditions) BY THE NEW HOME COMPANY INC 15231 LAGUNA CANYON ROAD 1 Ersn Cntrl 503-639-4175 BY KAWANAMI,MARK SUITE 250 2 GEO TECH REQUIRED 15231 LAGUNA CANYON RD STE IRVINE,CA 92618 PRIOR TO POUR 250 PHONE: PHONE: 503-312-6213 FAX: Total Fees: $24,015.16 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and ell other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR gc9-nn1-nnin thrn„nh(1 59-nn1-nnon Yn maw nhtain a rnnv of that n ileac nr d,rart nneaefinna to(II WC hw ro0inn ana 9Q9 10R7 nr 1 Ann Q'19',IAA issued By: Permittee Signature: Sete Appatinn. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each inspection. Building Permit Application Residential RECEDi LLJ FOR OFFICE USE ONLY - City of Tigard Received Permit No: e 13125 SW Hall Blvd.,Tigard,OR 97223 APR 1 2023 DateBy: g I 1 12 23 rip MST Zo 23.001 b5 • Phone: 503.718.2439 Fax: 503.598.1960 Plan Rev ew 2� ,25 Sw�2O/L3.000q1 DateBy: Other Permit TIGARD Inspection Line: g503.63 p4175 CITY OF TIGARD Date Ready/By. ` 1 (,n „.4 • orris: ® See Page4 for Internet: www.tigard-or.gov ov BUILDING DIVISION Notified/Method: i ) if Supplemental Information TYPE OF WORK REQUIRED DATA:1-AND 2-FAMILY DWELLING E New construction ❑ Demolition Permit fens*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑ Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. Valuation: $� 2, C6.3 a ❑� I-and 2-family dwelling IDCommercial/industrial l 0 Accessory building DI Multi-family Number of bedrooms: --3-- ❑Master builder ❑Other: Number of bathrooms: Vt%?.i rat ttv^M 2( ' ( A $., 4 iJB SITE INFORMATION AND LOCATION Total number of floors: 3 I14g i,r,< � ° oa . �^ Job site address:13655 SW 165th ave New dwelling area: l96 square feet I eil City/State/zIP:Sherwood/OR/97140 Garage/carport area: '2 square feet I(13 Suite/bldg./apt.no.: Project name:River Terrace Town Center Covered porch area: square feet I l v Cross street/directions to job site: Deck area: / square feet SW Jean I ru use rd Other structure area: square feet REQUIRED DATA:COMMERCIAL-USE CHECKLIST Subdivision:River Terrace Lot no.:76 Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all Tax map/parcel no.:parcel no: 2S1060003300 equipment,materials,labor,overhead,and the profit for the DESCRIPTION OF WORK work indicated on this application. Valuation: S RPquestinD Deferred SDC fees Existing building area: square feet New building area: square feet 1 I] PROPERTY OWNER ❑ TENANT Number of stories: NamCTNHC OREGON LLC Type of construction: Address:15231 Laguna Canyon RD STE 250 Occupancy groups: City/State/ZIP:Irvine/CA/92618 Existing: Phone:(503)310-7571 Fax:( ) New: © APPLICANT ❑ CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name:TNHC OREGON LLC Structural plan review fee(or deposit): Contact name:Frank Sandoval FLS plan review fee(if applicable): Address:15455 NW Greenbrier Parkway Suite 240 Total fees due upon application: City/State/ZIP:Beaverton/OR/97006 Phone:(503 ) 310-7571 Fax: :( ) Amount received: PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* E-mail: fandoval@nwhm.com Commercial and residential prescriptive installation of CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System. Business name:TNHC OREGON LLC Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:15231 Laguna Canyon RD STE 250 Solar Installation Specialty Code checklist. City/State/ZIP:Irvine/CA/92618 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(503 )310-7571 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.:241108 �{ Total fee due upon application: $201.60 Authorized signature: f This permit application expires if a permit is not obtained !/ /� within 180 days after it has been accepted as complete. Print name:Frank Sandov Date: l e•1,� /z0g3 *Fee methodology set by Tri-County Building Industry t ( Service Board. I:1Building\Permits1BUP-RESPermitApp.doc 01/25/2023 440-4613T(11/02/COM/WEB) Mechanical Permit Applicatill 1 ECEIVED FOR OFFICE USE ONLY !�� City of Tigard ReceivDan Bea MST LU.2 . Ud�ins lig II 13125 SW Hall Blvd.,Tigard,OR 97223 A�3 1 j 2023 Plan Review Permit No. ' Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit: T it.A N 1) Inspection Line: 503.639.4175 CITY OF Ti r Date Ready/By: Jnds: ® See Page 2 for Internet: www.tigard-or.gov BUILPIr ( f. Notified/Method: Supplemental Information TYPE OF WORK COMMERCIAL FEE* SCHEDULE— USE CHECKLIST Mechanical permit fees*are based on the value of the work ®New construction ❑Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑ Demolition ❑ Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENT/SYSTEMS FEES* ® 1-and 2-family dwelling D Commercial/industrial Accessory building For special information use checklist. ❑Multi-family ❑ Master builder ❑ Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/coaling: Air conditioning 1 46.75 Job site address:13655 SW 165th ave Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Sherwood OR 97140 Furnace 100,000+BTU(ducts/vents) 1 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name:River Terrace Town Center Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or SW Jean Louise rd hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision:River Terrace Town Center Lot no.:76 Other fuel appliances: Tux map/parcel no.:2s1060003300 Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 1 33.39 Flue vent for water heater or gas NEW HOME CONSTRUCTION fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 ® PROPERTY OWNER 0 TENANT Environmental exhaust and ventilation: Name:TNHC OREGON LLC Rangehood/otherkitchen equipment 1 33.39 Address:15231 Laguna Canyon Rd STE 250 Clothes dryer exhaust 33.39 City/State/ZIP:I ry i n e CA 92618 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(503)310-7571 Fax:( ) Attic/crawlspace fans 23.32 la APPLICANT ❑ CONTACT PERSON Other: 23.32 Fuel piping: Business name:TNHC OREGON LLC $14.15 for first four;$4.03 for each additional Contact name:Frank Sandoval Furnace,etc. Address:15455 NW Greenbrier Parkway#240 Gas heat pump Wall/suspended/unit heater City/State/ZIP:Beaverton OR 97006 Water heater Phone:(503)310-7571 Fax::( ) FireplaceRange E-mail:fandoval@nwhm.com Barbecue `t r ' %• Clothes dryer(gas) Other. Business name:Pro Heating and Cooling, INC MECHANICAL PERMIT FEES* Address:4200 NW Leisy rd Subtotal City/State/ZIP:Hillsboro, OR 97124 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(971)205 4989 Fax:( ) State surcharge(12%of permit fee) COI lie.:209001 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 / -/�g,�; days after it has been accepted as complete. L.Authorized signature: Z71Z '�• " Fee methodology set by Tri-County Building Industry Service Board Print name:Ella Duran Date:3/17/2023 I:1Buiding1Permia\MEC_PermiiApp_040113.doc 440-4617T(11/02'COM/WEB) ' Electrical Permit Application RECEIVE" FOR OFFICE USE ONLY City of Tigard Received 1 Date/By: Permit II:: MST 101%•60165 7 III g qi 13125 SW Hall Blvd.,Tigard,OR 97223 APR 1 f 2023 Plan Review Related Permit#: ' Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Inspection Line: 503.639.4175 r " Ready Date/By. Jaris Et See Page 2 for TIGARD Internet www.tigard-or.gov pt .Notificdi.Mcthod: I Supplemental Information TYPE OF WORK PLAN REVIEW E New construction ❑ Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w,titems checked). ❑Service or feeder 400 amps or more 0 Building over three stories. D Demolition ❑ Other: where the available fault current 0 Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. E 1-and 2-family dwelling ❑ Commercial/industrial ❑ Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑ Multi-family ❑ Master builder ❑ Other: ❑Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived ❑Addition of new motor load of system. Job#: Job site address:13655 SW 165th ave I00HP or more ❑"A","E�, 'l-z","1.3 City/State/ZIP: ❑Six or more residential units. occupancy. y Sherwood OR 97140 ❑Health-care facilities. ❑Recreational vehicle parks. Suite/bldg./apt.#: Project name:River Terrace Town Center 0 Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: FEE SCHEDULE SW Jean Louise rd Description I Qty. I Each 1 Total I New residential single-or multi-family dwelling unit. Subdivision:River Terrace Town Center Lot#: - -: 76 Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel#:2s1060003300 Ea.add'1 500 sq.ft or portion 1 33.92 1 <ry DESCRIPTION OF WORK Limited energy,residential NEW HOME CONSTRUCTION (with above sq.ft.) 75.00 z Limited energy,multi-family 75.00 2 residential(with above sq.ft.) _ Renewable Energy ❑ See Page 2 ® PROPERTY" OWNER 0 TENANT Services or feeders installation,alteration,and/or relocation Name:TNHC OREGON LLC 200 amps or less 1 100.70 2 Address:15231 Laguna Canyon Rd STE 250 201 amps to 400 amps 133.56 401 amps to 600 amps 200.34 2 2 City/State/ZIP:Irvine CA 92618 601 amps to 1,000 amps 301.04 2 Phone:603 310-7571 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email:fsandoval@nwhm.com relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 ® APPLICANT Branch circuits-new,alteration,or extension,per panel ❑, CONTACT PERSON _;' A.Fee for branch circuits with Business name:TNHC OREGON LLC above service or feeder fee, 7.42 each branch circuit Contact name:Frank Sandoval B.Fee for branch circuits without service or feeder fee,first 56.18 2 Address:15455 NW Greenbrier Parkway#240 branch circuit City/State/ZIP:Beaverton OR 97006 Each add'I branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(503 310-7571 Fax: :( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email: fsandoval@nwhm.com Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name:Alameda Electric Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy 0 See Page 2 2 Address:3415 NE 4th panel,alteration,or extension. City/State/ZIP:Portland, OR 97213 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(503 3192192 Fax:( ) Investigation(1 hr min) 90.00/hr Industrial plant(I hr min) 78.18/hr Email:solarpdX@me.com Inspections for which no fee is 90.00/hr CCB Lie.:199188 Electrical Lie.:c923 Suprv.Lie.:4754S specifically listed(/)hrmin) 1 ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: Subtotal: Print name:Dave Lister Date:3/17/2023 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature:� `� TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name:Dave Thompson Date:3/17/2023 days after it has been accepted as complete. • Number of inspections allowed per permit. I\BuildinglPermits1ELC_PermitApp_ErR_ERE.doc Rev 06/17/2015 440-4615T(I1/05/COM/WEB Plumbing Permit A licat ‘ Building Fixtures ;KZI s FOR OFFICE USE ONLY City of Tigard 2 1 7 2023 Received41 13125 SW Hall Blvd.,Tigard,OR 97223 Permit No: MST L(7 L� 0010 O I�� Date/By: Phone: 503.718.2439 Fax: 503 59 '1960 r ^A, )ry Plan ReviewDate/By Other Permit No.: Inspection Line: 503.639 4175 (�- Date Read i6 nods. See Page 2 for TIGARD Internet: www.ti and-or.goy y Y K g g� Notified/Method_ Supplemental Information TYPE OF WORK FEE* SCHEDULE ®New construction ❑ Demolition For special information use checklist Description Qty. Ea. Total ❑Addition/alteration/replacement ❑Other: New 1-2-family dwellings(includes 100 ft.for each utility connection) CATEGORY OF CONSTRUCTION SFR(1)bath 312.70 ® 1-and 2-family dwelling IIICommercial/industrial SFR(2)bath 1 437.78 El Accessory buildingSFR(3)bath 500.32 ❑Multi-family Each additional bath/kitchen 25.02 ❑Master builder ❑Other: Fire sprinkler( sq.ft.) Page 2 JOB SITE INFORMATION AND LOCATION Site utilities: Job site address:13655 SW 165th ave Catch basin or area drain 18.76 Drywell,leach line,or trench drain 18.76 City/State/ZIP:Sherwood OR 97140 Footing drain(no.linear ft.:_) Page 2 Suite/bldg./apt.no.: I Project name:River Terrace Town Center Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 SW Jean Louise rd Rain drain connector 18.76 Sanitary sewer(no.linear ft.: ) Page 2 Storm sewer(no.linear ft.: ) Page 2 Water service(no.linear ft.: ) Page 2 Subdivision:River Terrace Town Center I Lot no.:76 Fixture or item: Tax map/parcel no.:2s1060003300 Backflow preventer 31.27 DESCRIPTION OF WORK Backwater valve 12.51 Clothes washer 25.02 NEW HOME CONSTRUCTION Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 ® PROPERTY OWNER J 0 TENANT Expansion tank 12.51 Name:TNHC OREGON LLC Fixture/sewer cap 25.02 Floor drain/floor sink/hub 25.02 Address:15231 Laguna Canyon Rd STE 250 Garbage disposal 25.02 City/State/ZIP:Irvine CA 92618 Ilose bib 25.02 Phone:(503 $10-7571 Fax:( ) Ice maker 12.51 ® APPLICANT El CONTACT PERSON Interceptor/grease trap 25.02 Business name:TNHC OREGON LLC Medical gas(value:$_) Page 2 Primer 12.51 Contact name:Frank Sandoval Roof drain(commercial) 12.51 Address:15455 NW Greenbrier Parkway#240 Sink/basin/lavatory 25.02 City/State/ZIP:Beaverton OR 97006 Solar units(potable water) 62.54 Phone:(503 $10-7571 Fax: :( ) Tub/shower/shower pan 12.51 E-mail:fsandoval@nwhm.com Urinal 25.02 Water closet 25.02 CONTRACTOR Water heater 37.52 Business name:G&B Plumbing & Sons, INC Water piping/DWV 56.29 Address:PO BOX 92 Other: 25.02 City/State/ZIP:St. Paul, OR 97137 Subtotal Phone:(503 868 1417 Fax:( ) Minimum permit fee: $72.50 CCB Lie.:184372 Plumbing Tic.no.:fj@$ toll\ Plan review (25%of permit fee) State surcharge(12%of permit fee) Authorized signature: l,�/Q/J/J-r� TOTAL PERMIT FEE Print name:Kelly Fowler / v Date:3/17/2023 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. *Fee methodology set by Tri-County Building Industry Service Board. L\Building\Permits\PLMU-PermitApp.doc 10/01/09 440-4616T(10/09JCOMI/WEB) „ a, ,-/r7. v."`x raa va 'a+, N,'_ L.1 r 14.%-a (I-- A `aEOTECHN CAL SA-ArCl�:=L�(i-8 . 1111 v R:Pc PT S REQUIRED BEFORE THE FOOTING Building Division %),Y s c 1”, -.F-4 'is APPAr)VE ne & Two-Family Dwelling TIGARD ss' al. , ry; 'e Fees Checklist PERMIT INFORMATION: Application Date - FEE VERSION SU (Lf 2 O2Z- Permit#: m S T 2 z —c_cc,I (p S Plan #: Z(p 50 D(_L)rJ Floors: 3 Valuation: t4 Di,. ,1,53, it" Covered Porch: .--- Basement 112, Bedrooms: I Deck: 1"Floor t 17. WC (toilets) 3 Deck Cover: ----_— 2 Floor t,I Lavatories S Patio Cover ----- 3 d Floor Tub/shower 3 Accessory Struct. R-3 Total 2J1(D 9 Laundry Tray Water Heater I / Gas lec Garage SvZ Exhaust Vents S Gas Flue Vents ________ Total for Elec. 2 7 / Backflow Prey. CrurnIC'esy Heat Pump (CAC ') # for ElectricalLI BBQ -, Gas Fireplace -.P .0 #Fuel Lines 3 FEES: Description: Fee Applies: Fee Entered: DC Prov Revw: Planning ,r Info Proc/Arch: Lg$2.00 (over 11x17) ?L Info Proc/Arch: Sm$.50 (up to 11x17) 9 Metro CET: Residential Use School CET: District ,....__A Tigard CET: Admin Tigard CET: ODHCS Tigard CET: AH Electrical Permit: Permit Fee: Limited Energy: 12% State Surcharge ✓ Mech. Permit: Permit Fee: 12% State Surcharge Plumbing Permit: Permit Fee: 1/ 12% State Surcharge Erosion Control: w/Permit- Ping 1 Notes: I:\Building\Forms\ResPlanCheckFees_Dec2022_AA.doc 12/21/22 Page 1 *Update zoning on site plan and confirm name of Tract I City of Tigard (shows as Tract L on PDR) tts COMMUNITY DEVELOPMENT DEPARTMENT Building Permit Review - Residential TIGARD r1 h I Building Permit #: MST Ln L'' t)Q lo5 Site Address: 13655 SW 165th Ave 0 Verified in Accela Project Name: RT Town Center Lot/Unit #: 76 Proposal: New detached SFR Zone: RES-C Housing Type: 0 SFR(0 Single Detached ❑ Duplex❑Triplex El ADU) ❑ Rowhouse❑Cottage Cluster❑ CYU ❑Quad El Other Required Site Plan Elements: 0 3 copies of site plan on max 11x17" O Drawn to standard scale ❑ Rita„ t,G..,, J.;I, t; / L1..G N aection O North arrow 0 Street and site trees shown/ labeled O Site address, project name, lot # TELL eeL-L.L:.., L.__ __.._r, _L ..futurity O Street names (N/A for SFR) O Applicant name and phone # El Courtyard rcctanglc dimcnaioncd (if applicable) O Lot and setback dimensions - "`'' �� '""" *'`"7' Vision clearance not required ❑ti,,>,,,,,y >L, &> ,, A y 0 Utility locations &easements due to tract/private access. O Footprint of new structure and FFE 0 Property corner elevations O Sidewalk/driveway dimensioned ❑ LID/. (_ 1,000 O Lot area and lot coverage percentage 0 Erosion control Required Elevation Plan Elements: (For SFR: calcs needed only on street-facing) Summary table with calculations for: O Drawn to standard scale 0 Total façade area O Building height dimensioned 0 Total window and door area O Facade dimensioned O Windows and doors dimensioned 0 Garage doors dimensioned Re oor Plan Elements: (Not required for El Summary table that includes ❑ Each story dimensioned ❑Total floor area ❑ Each story floor area calculated ❑ r story Planning Review The following standards have been met: Setbacks 0 Front: 8/12 Rear: 3 alley Side: 3 Min/Max Street Side: 7 / Garage: 3 alley Height 0 Max. Height: 35 Proposed Height: 29 0 Yes ❑ N/A Landscape El Yes 0 N/A Screening (Quad only) Et/Yes ❑ N/A % Window Coverage 21% ❑ Yes 0 N/A Garage (SFR Only) Parking (Other Res) 0 Yes El N/A Entrance (SFR, Rowhouse, Quad only) El Yes 0 N/A Other building design standards (Rowhouse only) El Yes 0 N/A Accessory Structure Standards El Yes 0 No Qualifying pre-existing unit exempt from standards (Cottage unit only) .ditional standards for Courtyard Units, Cottage Clusters, Rowhouses, and Quads: ❑ Ye - /A Unit Count: ❑ Yes ❑ N • of Width and Size ❑ Yes ❑ N/A Pat Additional standards for -• rtyard Units and Cottage Clusters only: ❑ Yes ❑ N/A Unit Area: ❑ Yes ❑ N/A Floor Area (per story) ❑ Yes ❑ N/A Courtyard 0 Yes 0 N/A Fence . El Yes ❑ No PIN/A Clean Water Services - Service Provider Letter(lot platted prior to 9/10/1995) ❑ Yes ❑ No ON/A Public Facilities Improvement (PFI) Permit: Required: ❑ Yes El No Applied For: ❑ Yes ❑ No, stop intake •Nt' lcr.‘ m Sensitive Lands: 0 Yes El No m Main Land Use Case #s: PDR2021-00004 El Conditions met m Applicant notified of land use expiration date: Submit development plans by 1/31/25. Final occupancy by 1/31/27 Approved By Planning: /i._ Date: 4/12/23 Notes Revision 1: El Approl d ❑ Not Approved Date: Revision 2: ❑ Ap. 5 ed El Not Approved Date: sirj. Building Permit Submittal Original Submittal Date: 111 I2a23 Site Plans #: Building Plans #: ��3 Building Permit #: l 'Building permit # entered on page 1 Workflow Routing: B'Planning 154ngineering 0/Permit Coordinator "Building Workflow Sign-off: ign-off for Planning (include notes from planning review) Route Documents: Engineering: (1) copy of permit application, (1) site plan, (1) building plan and original plan review routing form. I, Cuilding: original permit application, site plans, building plans, engineer and IIQ 'n ,- , beam calculations and trust details, if applicable, etc. Permit Technician: -WI'vf W✓ PLAn...6L' Notes: t Date: '1 I/5IZ 2-3 v Engineering Review ❑ PFI Permit: Slope at building pad: 9®,4 ok ❑ onditions met prior to issuance of permit ❑ asements (encroachments) per engineering conditions of approval and plat k) ❑ ater Quality/Quantity Facility: sIN Assess Water Quality Fee in-lieu: ❑ Yes ❑ No Assess Water Quantity Fee in-lieu: ❑ Yes ❑ No LIDA Facility on lot: CI ❑ No Add Fee: CI CINo 0 inal Plat Recorded 0 NOT Approved: Date: Notes: Approved By Engineering: Date: /Z2Z S Revision 1: ❑ Approved ❑ N Approved Date: Revision 2: 0 Approved ❑ Not Approved Date: Permit Coordinator Review A. lots, onditions met prior to permit a issuance a Approved, NOT Released: Date notified applicant: /ZZ/2C2 ❑ ENG Revisions Required: Date notified applicant: SDC Exemption: ❑ Applied for ❑ Received 7boes not apply )/SDC Fees Entered: Wash Co Trans Dev Tax: Yes El N/A Tigard Trans SDC: /Yes ❑ N/A /Deferred Parks SDC: ,'Yes ❑ N/A ,Deferred LIDA ❑ Yes�p ``e N/A �K to Issue/Approved by Permit Coordinator: �C}\i 1�� T Date: J- -3 T Revision 1: ❑ Approved ❑ Not Approved Date: Revision 2: ❑ Approved El Not Approved Date: RECEIVED City of Tigard MAY 3 202 3 IlCIDeferral Until Occupancy Request BUILDINGDIVISION T f G A R D Washington County Transportation Development Tax(TDT),Transportation and Parks System A Development Charges (SDCs) This form is to be signed and submitted prior building permit issuance or,if no building permit is required,then upon land use approval(TMC 3.24,as amended by Ordinance No. 21-09). Date: 4/27/2023 Site Address: 13655 SW 165th Ave Project River Terrace Town Land Use Case or Name: Building Permit#: MST2023-00165 Center Tax Lot NA- Lot 76 Total Parks $11,830.00 #: Amount*: TDT Total TSDC Amount; N/A Amount*: $12,004.00 *The total TSDC amount shown above is the sum of$7,760.00 for TSDC-Improvement,S 448.00 for TSDC- Reimbursement,and$3.796.00 for TSDC-River Terrace,if applicable.. *The total Parks SDC amount shown above is the sum of$6,812.00 for Parks-Improvement,$ 1,887.00 for Parks- Reimbursement,and either$ N/A for Parks-Neighborhood or$3,131.00for Parks-Neighborhood River Terrace. This constitutes my request to defer payment of the TDT,TSDC, and Parks SDCs, as provided above,to prior to final inspection. Payment of the TDT,TSDC,and Parks SDCs may be deferred until issuance of the occupancy permit. In requesting this option, I understand that any deferred TDT,TSDC, and Parks SDCs must be paid prior to final inspection. TDT may only be deferred if the TAT is greater than the amount for a single-family residence. I further understand that the amount of TDT due on deferred obligations shall be the amount in effect at the time of issuance of the building permit. For a deferral request to be accepted both the Property Owner and the Developer must sign this request. Property Own . Date: -5-'/—�� ��2: -'---- �/ e' Developer: � Date: cvc\__-i( 4/27/2023 Permit Coordinator: Date: Hope Pollard From: Boris Piatski Sent: Friday, June 30, 2023 7:59 AM To: Agnes Lindor; Hope Pollard Cc: Joe Wisniewski Subject: FW: River Terrace Town Center Hello Agnes and Hope, Please see the email below.The listed permits can be issued according to the 31 permits agreement without occupancy, except for the very last address, 13875 SW Mercantile Terrace, I am not sure where is this address located. Thank you, e Boris Piatski, PE 1 Project Coordinator City of Tigard I Division Direct: 503-718-2463 I Cell:971-255-7724 CTVOF Tigard 13125 SW Hall Boulevard, Tigard OR 97223 I Boriso@ tgard-or.gov From: Christopher Walther <cwa lther@ NewHomeCo.co m> Sent:Thursday,June 29, 2023 4:37 PM To: Boris Piatski<borisp@tigard-or.gov>;Joe Wisniewski<joew@tigard-or.gov> Cc: Patrick Espinosa <patrick@pacific-community.com>; Francisco Sandoval<fsandoval@NewHomeCo.com>; Pamela Verdadero<pverdadero@NewHomeCo.com>; Daniel Mathies<Danielm@dtexcavation.com>; Shaun Smith <Shauns@dtexcavation.com> Subject: RE: River Terrace Town Center Boris, Thanks for the response, it's disappointing to hear that we can't get them today because the base lift was completed. Will we be able to pull these on Monday morning, also we will start installing top lift of asphalt tomorrow and finish it on Wednesday next week, we would finish Monday but the plants are closed. The address and building permit numbers that we would like released are listed below, let me know if you have any other questions. Lot ADDRESS Permit# 20 16638 SW Jean Louise RD MST2023-00 226 21 16646 SW Jean Louise RD MST2023-00 227 22 16658 SW Jean Louise RD MST2023-00 228 23 16664 SW Jean Louise RD MST2023-00 229 24 13905 SW 166th Ave M5T2023-00 106 25 13917 SW 166th Ave M5T2023-00 103 104 16694 SW Streamwood Ln MST2023-00 105 1 103 16672 SW Streamwood Ln MST2023-00 140 102 16668 SW Streamwood Ln MST2023-00 135 101 16644 SW Streamwood Ln MST2023-00 107 100 16632 SW Streamwood Ln MST2023-00 137 145 13623 SW 166th Ave M5T2023-00 115 144 13637 SW 166th Ave MST2023-00 114 143 13649 SW 166th Ave MST2023-00 113 142 13657 SW 166th Ave MST2023-00 126 141 13673 SW 166th Ave MST2023-00 124 140 13685 SW 166th Ave MST2023-00 158 69 16564 SW Streamwood Ln MST2023-00 125 70 16576 SW Streamwood Ln MST2023-00 144 71 16588 SW Streamwood Ln MST2023-00 143 72 16596 SW Streamwood Ln MST2023-00 159 68 16552 SW Streamwood Ln MST2023-00 139 73 13625 SW 165th Ave MST2023-00 163 74 13639 SW 165th Ave MST2023-00 162 75 13647 SW 165th Ave MST2023-00 164 76 13655 SW 165th Ave MST2023-00 165 77 13671 SW 165th Ave MST2023-00 157 95 13668 SW 166th Ave MST2023-00 160 96 13654 SW 166th Ave MST2023-00 161 13875 SW Mercantile Terrace Sincerely, Christopher Walther Vice President, Construction New Home Co. 15455 NW Greenbrier Parkway, Suite 240 Beaverton, OR 97006 Cell: 503-312-6213 NewHomeCo.com This message contains confidential information and is intended only for the intended recipients. If you are not an intended recipient you should not disseminate,distribute or copy this e-mail. Please notify the sender immediately by e-mail if you have received this e-mail by mistake and delete this e-mail from your system.E-mail transmission cannot be guaranteed to be secure or error-free as information could be intercepted,corrupted, lost, destroyed, arrive late or incomplete,or contain viruses.The sender therefore does not accept liability for any errors or omissions in the contents of this message,which arise as a result of e-mail transmission. If verification is required please request a hard-copy version. From: Boris Piatski<borisp@tigard-or.gov> Sent:Thursday,June 29, 2023 3:55 PM To:Christopher Walther<cwalther@NewHomeCo.com>; Joe Wisniewski<loew@tigard-or.gov> Cc: Patrick Espinosa <patrick@pacific-communitv.com>; Francisco Sandoval <fsandoval@NewHomeCo.com>; Pamela Verdadero<pverdadero@NewHomeCo.com>; Daniel Mathies<Danielm@dtexcavation.com>;Shaun Smith <Shauns@dtexcavation.com> Subject: RE: River Terrace Town Center 2