Loading...
Permit (3) CITY OF TIGARD MASTER PERMIT ✓� Permit#: MST2023-00323 COMMUNITY DEVELOPMENT Date Issued: 08/02/2023 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 2S109AC09300 Jurisdiction: Tigard Site address: 13108 SW FORAN HILLS CT Subdivision: FORAN HILLS Lot: 14 Project: Eyde Project Description: Rooftop solar system 5.88 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $5,304.94 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bcktiw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Fum<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp SrvclFeeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Roof top solar array 5.88 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: EYDE,MATTHEW SUMMERFIELD Required Items and Reports(Conditions) EYDE,DANA MICHELLE 13108 SW FORAN HILLS CT TIGARD,OR 97224 PHONE: PHONE: FAX: Total Fees: $356.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR o52nn1-nn1n thmi f1AR Qc ..nM nil may nhtain a rnnv of iha ndole nr dirarl ni,xfinne M hl INr:hu Tallinn gill 949 1QR7 nr 1 AM V29 9144 � C Issued By: r Permittee Signature: �� D �l l Gt i • ��7 Call 503.639A175 by 7:00 a.m.for the next available Inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the lob site at the time of each Inspection. VEDE Cectrical Permit Application EGEI FOR OFFICE USE ONLY City of Tigard JUL I. $ 2023 Received qi 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Re iew yA��11�1 —OC�3d J 2 Phone: 503.718.2439 Fax: 503.598.19�r OFTIG'A{ L; Date/By: Related Permit#: T 1 GAAD Inspection Line: 503.639.4175 i p�!� ,I /� Ready Date/B Loris: lid See Page 2 for Internet: www.tigard-orgov ���i-nl1 Pt.7 - V,,'tl/�`i t;ntifiediMetlmd: Supplemental Information TYPE OF WORK PLAN REVIEW ❑ New construction H Addition/alteration/replacement Please check all that apply(submit 2 sets of plans r-'item,checked) ElService or feeder 400 amps or more 0 Building over three stories ❑ Demolition ❑Other. . where the available fault current ❑Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or ❑Floating buildings. 0 1-and 2-family dwelling E C ommercial/industrial ❑Accessory building ess to ground,or exceeds I4,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑ Multi-family ❑ Master builder ❑Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived ❑,Afddition of new motor load of system. Job #: I Job site address: 13108 SW Foran Hills Ct,Tigard, Oregon, 9722¢OOHPnr more. ❑"A'°,°'e',"l-2","la", City/State/ZIP: ❑Six or more residential units. occupancy. 0 Health-care facilities. ['Recreational vehicle parks. Suite/bldg./apt.#: Project name: Matt Eyde ❑Hazardous locations. ❑Supply voltage for more than 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: ' i - '',v t. ' , ',`*r Description f Qty. i Each f Total * New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. l,000 sq.ft.or less 168.54 4 Tax map/parcel#: Ea.add'I 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential Rooftop Solar PV (with above sq.ft.) 75.00 2 limited energy,multi-fbmily 75.00 2 residential(with above sq.ft.) Renewable Energy 0 See Page 2 ® PROPERTY OWNER ❑ TENANT Services or feeders installation,alteration,and/or relocation Name: Matt Eyde 2(10 amps or less 100.70 1 2 Address: 13108 SW Foran Hills Ct,Tigard,Oregon,97224 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax: ( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: _ Date: 401 amps to 599 amps 168.54 2 Ea APPLICANT 0 CONTACT PERSON Branch circuits—new,alteration,or extension,per panel I - A.Fee for branch circuits with Business name: BRS Field Ops, LLC above service or feeder fee, 7.42 each branch circuit Contact name: Bryson Taylor B.Fee for branch circuits without Address: 1403 N Research Way service or£cede fee,frst 56.18 2 branch circuit City/State/ZIP: Orem, UT 84097 Each add'1 branch circuit 7.42 2 385)482-0045Miscellaneous(service or feeder not included) Phone:( Fax: :( ) Each manufactured or modular dwelling,service and/or feeder 67.84 2 Email: permitting.department@blueravensolarcom Reconnect only 67.84 2 CONTRACTOR Pump or irrigation circle 67.84 2 Business name: BRS Field Ops, LLC Sign or outline lighting 67.84 2 Address: 1403 N Research WaySignalnel, dreu (s)or extension. 0 See Page 2 2 panel,alteration,or extension. City/State/ZIP: Orem, UT 84097 Each additional inspection over allowable in any of the above Additional inspection(I hr min) 66.25/hr Phone:( 385) 482-0045 Fax:( ) Investigation(1 hr min) 90.00/hr Industrial plant(1 hr min) 78.18/hr Email: permitting.department@blueravensolar.com Inspections for which no fee is specifically fisted Y,fir min) 90.00/fir CCB Lie.: 227185 Electricaalc.: C149 Suprv.Lic.: 6394S pe Y ( ELECTRICAI. PERMIT FEES Suprv.Electrician signature,required: / (gel Subtotal: Print name: Shan Whittaker Date: 07/17/2023 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: $/1tJrOtc raylm- TOTAL PERMIT FEE: Permitting Coordinator This permit application expires if a permit is not obtained within I80 Print name: Bryson Taylor Date: 07/17/2023 days after it has been accepted as complete. * Number of inspections allowed per permit. Ic,Building(Permits\ELC_PermiiApp_ELR_EREdoc Rev 06i I72015 440-46151'(I I'05iCOM/WEB ill '4 Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Fee for all residential systems combined: $75.00 Description 1 Qty. 1 Each 1 TotalRenewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any_of the above: ❑ Other: Each additional inspection is charged at an hourly(1 hr min) 66.25/hr Inspections for which no fee is 90.00/hr specifically listed(/hr min) COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00 Subtotal(Enter on Page 1):Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations tlBuildingV'ermil$liLC_PcrmitApp_Iil.R_ERE.doc Rev 06/17/2015 RECEIVED City of Tigard AL it 8 2023 • " Building Division ‘.:►►r Lk'TIGARD • 13125 SW Hall Blvd,Tigard, OR 97223 BUILDING DIVISION Phone: 503.718.2439 Fax: 503.598.1960 T I GARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 13108 SW Foran Hills Ct, Tigard, Oregon, 97224 City: Zip: Owner's Name: Matt Eyde Date: 07 / 17 /2023 Contractor's Name: BRS Field Ops, LLC CCB #: 227185 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? © No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure © Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes © Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for ❑� Yes the prescriptive path. above ❑ No 1 1:/Building/Forms/PhotoVoltaic-Checklist02-01-t 1.docx Is the construction material wood and does Yes Type of If"Yes", qualifies for the construction qualify ❑ No the prescriptive path. Construction as "conventional light frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. 2Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight © Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If"Yes", qualifies for with Section 305.4(3) of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. E of composition shingle. Is the roof mounted © Yes Connections of solar assembly the solar assembly connected to roof No If"Yes",pqrescriptive p for to the roof framing or blocking ❑ the prescriptive path. directly? 2 I:/B uilding/Forms/Photo V oltaic-Checklis t02-01-I I.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. %2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof 0 Yes the prescriptive path. surface. ❑ No 3 t:/B uilding/Forms/Photo V oltaic-Checklist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. • Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Solar Model Number: REC420AA PURE-R Listing Agency: UL 4 1:1Bu ilding/Forms/Photo V oltaic-Checklist02-01-11.docx