Loading...
Plans , Ilk The City of I igard and its er;p cyees shall not be r y; .)€...asible for discrepancies y$rich may appear herein. #8 Awg THHN �` RECEIVED Arrayof 13 modules and inverter Cobb Irl #2 13 108PLUS-72-2-US MIcrolnverters aRed-L2 JBox \ Gran Ground\ �, JUL 5 2023 ° CITY OF TIGARD Approved plans Module M BUILDING DIVISION shall be on job site. #8Awgn+HN 3/4 EMT or FMC Ll �mund#12 Awg Array of 7 modules and Inverter CadsBlaCk DUX ss ftft 7 IQ8PLUS-72-2-US Microinverters -nd JBox \ Green Gmund N _ 1N1 __ NEW 2 SOLAR l COMBINER w w U Module Modub ... ECU /Z__ 15A CITY OF TIGARD . o S REVIEWED PUI CODL COMPLIANCE � o Approved: [ VI OTC: [ 1 Permit#: VAS VZ 2- - Op3L(-f l Address: 1lole.S. SW 17c..r1ahY• L_o&p Suite #: , By: AIV Date: 741/2-. OFFICE COPY On Home Table t.23 Internal Q Cable VRise(Landscape 60 Cell Cable Q-12-17-240 VALIDITY' OF PERMIT 108+Microinverters per branch THE ISSUANCE OF A PERMIT 1 2 3 4 5 6 7 8 9 10 11 12 13 BASED ON CONSTRUCTION DOCUMENTS AND OTHER Page 1 of 2 Current(A) 1.20 2.40 3.60 4.80 6.00 7.30 8.50 9.70 10.90 12.10 13.30 14.50 15.70 DATA SHALL NOT PREVENT Job. Address. PNW1123 Sivakumar Mohan, THE CODE OFFICIAL FROM ran VRise(V) 0.03 0.09 0.19 0.31 0.47 0.65 0.87 1.12 1.40 1.71 2.05 2.43 2.83 REQUIRING THE CORRECTION16653 SW Da rwiin Rev: Loop VRise(%) 0.01 0.04 0.08 0.13 0.19 0.27 0.36 0.47 0.58 0.71 0.86 1.01 1.18 OF ERRORS. ORSC 105.4 AM Tigard,OR 97224 PROSTAT ELECTRIC&SOLAR AC disco 8 PGE Meter grouped within loft on exterior wall of home Utility Meter ell NEW MAIN ME 60A 200A FUSED Leviton AC DISCO 200A 26F4U0SAES y ' MOW. ® mom On Home In Home #6 AWG THHN PV Module Ratings NEC 690.54 AC Point of 3/4"FMC or EMT Manufacture: Silfab Solar Interconnection #8 AWG THHN Ground #sAwc 3/4"FMC or EMT Distance 5' Model#:SIL-400 HC+ Rated AC Output:24.2 Amps Ground fi 12AWG Open-Circuit Voltage: 43.02V Nominal AC Voltage: 240 Vac Distance 5' Operation Voltage: 36.05V Inverter Specs: Max String Voltage: 1000V Manufacture:Enphase Operating Current: 11.1A Module:IQ8PLUS-72-2-US Short-Circuit Current: 11.58A Max Output Current: 1.21A Max Series Fuse: 20A Nominal Output Volts: 240V Maximum Power(STC):400W Output Frequency: 47Hz-68Hz Total number of Modules: 20 Power Tolerance: +10W Output Volt Range:211V-264V System Size: 8 kW 240Vac Voltage Drops Description Current(A) Wire Size(Awg) Dlstence(feet) Percent(%) Trunk Cable 1.18 Jbox to Comb 15.73 8 60 0.61 Comb to AC Disco 24.20 8 5 0.08 AC Disco to Main 24.20 6 5 0.05 Page 2 of 2 Job: Address: PNW1123 Sivakumar Mohan, Rev: Lakshmy Sudhakaran 16653 SW Darwin Loop Total 1.92 AM Tigard,OR 97224 PROSTAT ELECTRIC&SOLAR Plot Spans Weight of solar < 4.5 Ib/sgft Spans comply with 2308.7.2 2x4 Engineered Trusses 12:12, single layer comp roof Utility Meter Main Panel AC Disco Combiner Home driveway Elevation 12" Section 3111.3.4.8.1 40' o <18" Section 3111.3.5.3.4 0 Roof Area Boundary 0 145° 3#' 94' 24' Groundjto eve Ground to peak Page 1 of 3 Job: Address: PNW1123 Sivakumar Mohan, Lakshmy Sudhakaran Rev: 16653 SW Darwin Loop AM Tigard, OR 97224 PROSTAT ELECTRIC & SOLAR Detail 0 \ N 2 y� 212" Section 3111.3.4.8.1 (ridge) 75 3" sun e1 Solar Array Coverage: f Y Solar Array sqft= 302 o Roof Area Boundary sqft = 1751 40.8" Solar Array covers 17% of roof surface Solar Array Setbacks: Page 2 of 3 z12" along all horizontal ridges per Section 3111.4.8.1 Job: Address: PNW1123 Sivakumar Mohan, Suneye Legend (degrees): Lakshmy Sudhakaran Solar Array Attachments: Solar racking attachments per 1. Tilt = 45 Azimuth = 180 Rev: 16653 SW Darwin Loop 3111.3.5.3.3 24" OC within 3' of edge hip eve or ridge, 48" 2. Tilt= 45 Azimuth = 270 AM Tigard, OR 97224 OC elsewhere PROSTAT ELECTRIC & SOLAR Comp Roof 2x framing Attachments spaced so that 24" Max on Center no point load exceeds 50 lb Solar Pane ( I I 4 PSF max II II111 I l I I I Racking Details: Panel connecte� I Manufacturer= Iron Ridge to rails with 1 connector ■ oimmis i� Model = XR100 for each 8 Sq feet or less 11111®f111®11 11111i1111 per rack manufacturer's specs I II - Attachment Details: Manufacturer= Iron Ridge Aluminum Rails to alternate---- Model = FlashFoot2 roof framing 4' OC max. Two rails per min. per panel 1111 I Panels 40.8" X 75.3" aprox. 2X joist/truss to mee Oregon Solar code span requirements 12„ Page 3 of 3 Max Job: Address: Min-A"SS lag embedded 2"min center of framing member 2 Layers or less PNW1123 Sivakumar Mohan, of roof material Lakshmy Sudhakaran lashed and sealed Rev: 16653 SW Darwin Loop roof penetration AM Tigard, OR 97224 PROSTAT ELECTRIC & SOLAR SILFAB PRIME SILFAB •�� SOLAR® SIL-400 HC. RELIABLE ENERGY. DIRECT FROM THE SOURCE . Designed to outperform. ( Dependable, durable, high-performance 2022 solar panels engineered for North American homeowners. ) SILFABSOLAR.COM CE o r!,,, fT Y I EC Fraunhofer C H U B B' !ntertek Intenek ISE ^ChuSi Dr.,td e ur and oinisxlon insurance to Siitah ELECTRICAL SPECIFICATIONS 400 Test Conditions STC NOCT Module Power(Pmax) Wp 400 298 Maximum power voltage(Vpmax) V 36.05 33.50 -- Maximum power current(lamas) i A 11.10 8.90 Open circuit voltage(Voc) i V 43.02 40,35 Short circuit current(Isc) A 11.58 9.34 Module efficiency % 20.2% 18.8% Maximum system voltage(VDC) V 1000 Series fuse rating A 20 Power Tolerance Wp Oto+10 Measurement conditions:SIC 1000 W/m'•AM 1.5•Temperature 25'C•NOCT BOO W/m'•AM 1.5•Measurement uncertainty a 3% Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by d5%and power by 0 to+10W. MECHANICAL PROPERTIES/COMPONENTS METRIC ` 9':4,-. a+ A. °'-.;.txl; IMPERIAL Module weight 21.3kg 10.2kg 471bs t0.41bs Dimensions(H xix D) 1914 mmx 1036 mmx 35 mm 75.3 in x40.8 in x1.37 in Maximum surface load(wind/snow)' ' 5400 Pa rear load/5400 Pa front load 112.8lb/ft,rear load/112.8 lb/ft'front load Hall impact resistance '. 025mm at 83 km/h a 1 in at 51.6 mph Cells 132 Half cells-Si mono PERC 132 Half cells-Si mono PERC 9 busbar-83 x 166 mm 9 bushel--3.26 x 6.53 in Glass 3.2mm high transmittance,tempered, 0.126 in high transmittance,tempered, DSM antireflective coating DSM antireflective coating Cables and connectors(refer to installation manual) 1350 mm,a 5.7 mm,MC4 from Staubli 53 in,a 0.22 in(12AW6),MC4 from Staubli Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, fluorine-free PVbacksheet Frame Anodized Aluminum(Black) Bypass diodes 3 diodes-3050045T(45V max DC blocking voltage,30A max forward rectified current) Junction Box UL3730 Certified,IEC 62790 Certified,IP68 rated TEMPERATURE RATINGS WARRANTIES Temperature Coefficient lsc +0.064%/°C Module product workmanship warranty 25 years" Temperature Coefficient Voc -0.28%/°C 1 Linear power performance guarantee 30 years Temperature Coefficient Pmax i -0.36%/°e 597.1%end 1st yr NOC7(±2°C) 45°C a 91.6%end 12th yr z 85.1%end 25th yr Operating temperature -40/+85°C >_82.6%end 30th yr CERTIFICATIONS ' SHIPPING SPECS UL 61215-1:2017 Ed.1"",UL 61215-2:2017 Ed.1"`,UL 61730-1:2017 Ed.1`",UL 61730- Modules Per Pallet: 26 or 26(California) 2:2017 Ed.1'"",CSA C222R61730-1:2019 Ed.2"`,CSA C222#61730-2:2019 Ed.2"`, Product IEC 61215-1:2016Ed,1" IEC 61215-2:2016Ed-1*",IEC61730-1:2016 Ed.2"`,IEC - 1 61730-2:2016 Ed.2"",IEC 61701:2020(Salt Mist Corrosion),IEC 62716:2013(Ammonia Pallets Per Truck I 34 or 31(California) Corrosion),UL Fire Rating:Type 2,CEC Listing*" Factory 1509001:2015 I Modules Per Truck i 832 or 806(Califomia) A Warning.Read the Safety and Installation Manual for mounting specifications and before handling,installing and operating modules. 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolacmm. PAN files generated from 3rd party performance data are available for download at silfabsolar.com/downloads. "` Certification and CEC Rating in progress.December2022,expected completion. 5, I . . ]� m L 75.3"[1914mm] ( E It to 12.1'[307mm]_ - 51.2[1300mm] 12.1"(307mm] 'co \ f SILFAB SOLAR INC. \Mounting Hole(x4) 800 Cornwall Ave 0.5" Bellingham WA 98225 USA --- T+@silfa solar.3 4 � Ir- info@silfahsolaccom OI SILPA B50LA R.COM 1770 Port Drive m 1.4"[35mm1 ® [E Ifl E Burlington WA 98233 USA r 1 2. 0 7+1360.569.4733 r© N + > co ao 240 Courtneypark Drive East N E b a Mississauga ON L5T 2Y3 Canada 3 E T+1905.255.2501 3 0.06" 53.15" of c s+1905.696.0267 C [1.5mm] [1350mm] @O y,il pia ',-. _... IL'13^..c= r- Cable Length i� Q Si1Mb-SIL-400-H[+.U, 202209w6 No reproduction Marry kind is allowed without �ralnage Hole(x6) 0 e � Utah Solar permission.Data andeion is subjMto > i modifications wkhom noriceotice.O Siltab SMxlnc., I 2022. b SomN is a registered trademark of 'y",,;."_...1 I 2.4"[60mm] 8"[200mm] L J EN PHAS E DATA SHEET I I• ENPHAZE -.ENG1143F le A♦ IQ8 �. r i ~ 1■ I N IR IQ8 and IQ8+ Microinverters Easy to install Our newest IQ8 Microinverters are the industry's first microgrid-forming,software- • Lightweight and compact with defined microinverters with split-phase power conversion capability to convert DC plug-n-play connectors power to AC power efficiently.The brain of the semiconductor-based microinverter • Power Line Communication is our proprietary application-specific integrated circuit(ASIC)which enables the (PLC)between components microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times • Faster installation with simple to changing loads and grid events,alleviating constraints on battery sizing for home two-wire cabling energy systems. High productivity and reliability • Produce power even when the x ' Enphase grid is down* • More than one million cumulative vet i-mtd hours of testing 00111' • Class II double-insulated Part of the Enphase Energy System,IQ8 Series I08 Series Microinverters redefine reliability enclosure Microinverters integrate with the Enphase IQ Battery, standards with more than one million cumulative • Optimized for the latest high- Enphase IQ Gateway,and the Enphase App monitoring hours of power-on testing,enabling an industry- and analysis software. leading limited warranty of up to 25 years. powered PV modules Microgrid-forming 143 • Complies with the latest advanced grid support" CERTIFIED • Remote automaticupdates for sa�err the latest grid requirements Connect PV modules quickly and easily to IQ8 Series IQ8 Series Microinverters are UL Listed as • Configurable to support a wide Microinverters using the included Q-DCC-2 adapter PV Rapid Shut Down Equipment and conform with cable with plug-n-play MC4 connectors. various regulations,when Installed according to range of grid profiles manufacturer's instructions. • Meets CA Rule 21(UL 1741-SA) requirements ©2022 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ8 Microinverters,and other •Only when installed with IQ System Controller 2, names are trademarks of Enphase Energy,Inc.Data subject to change. meets UL 1741. "'KM and IQ8Plus supports split phase,240V IQ8SP-DS-0002-01-EN-US-2022-03-17 installations only. I08 and IQ8+ Microinverters INPUT EATA IOC) 108-60-2-US Commonly used module pairings' w 235-350 235-440 Module compatibility 60-ce1l/120 half-cell 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell MPPT voltage range v 27-37 29-45 Operating range V 25-48 25-58 Min/max start voltage V 30/48 30/58 Max input DC voltage V 50 60 Max DC current'[module Ise] A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration lx1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit OUTPUT DATA IAC) I08-60-2-US Peak output power VA 245 300 Max continuous output power VA 240 P90 Nominal(L-L)voltage/range' v 240/211-264 Max continuous output current A 1.0 1.21 Nominal frequency Hz 60 Extended frequency range Hz 50-68 AC short circuit fault current over 3 cycles Arms 2 Max units per 20 A(L-L)branch circuit' 16 13 Total harmonic distortion <5% Overvoltage class AC port Ill AC port backfeed current mA 30 Power factor setting 1.0 Grid tied power factor(adjustable) 0.85 leading-0.85 lagging Peak efficiency % 97.5 97.6 CEC weighted efficiency % 97 97 Night-time power consumption mw 60 MECHANICAL DATA Ambient temperature range -40°C to+60°C(-40°F to+140°F) Relative humidity range 4%to 100%(condensing) DC Connector type MC4 Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-no fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environ.category/UV exposure rating NEMA Type 6/outdoor COMPLIANCE CA Rule 21(UL 1741-SA),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22,2 NO.107.1-01 Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to manufacturer's instructions. (1)No enforced DC/AC ratio.See the compatibility calculator at https://link.enphase.com/module-compatibility (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. 1O8SP-DS-0002-01-EN-US-2022-03-17 //�►. IRONRIDGE FlashFoot2 The Strongest Attachment in Sofa; IronRidge FlashFoot2 raises the bar in solar roof protection. The unique water seal design is both elevated and encapsulated, delivering redundant layers of protection against water intrusion. In addition, the 1 twist-on Cap perfectly aligns the rail attachment with the L lag bolt to maximize mechanical strength. , ,i i 4 I .41 y , i :„,,„,,,,,,,.,..,..,,,Q... Y G Sx . t "'£'. t � iiT"i>.MtlM1•1�a+7 snax Rzvs: ':. + u - q- .dim+ e< r q.. g1..:iffi-.',111, Twist-On Cap -.- „. _ FlashFoot2's unique Cap design encapsulates the lag bolt and locks into place with a simple Three-Tier Water Seal twist.The Cap helps FlashFoot2 deliver a FlashFoot2's seal architecture utilizes three superior structural strength,by aligning F layers of protection.An elevated platform the rail and lag bolt in a concentric diverts water away,while a stack of rugged load path. components raises the seal an entire inch. The seal is then fully-encapuslated by the Cap.FlashFoot2 is the first solar attachment to pass the TAS-100 Wind-Driven Rain Test. d Single Socket Size A custom-design lag bolt allows 11/ (11171) you to install FlashFoot2 with the same 7/16"socket size used on other Flush Mount System components. Water-Shedding Design An elevated platform diverts water away from the water seal. Installation Features B : A Alignment Markers Quickly align the flashing with chalk lines to find pilot holes. B , Rounded Corners Makes it easier to handle and insert under the roof shingles. C Reinforcement Ribs Help to stiffen the flashing and prevent any bending or crinkling during installation. Benefits of Concentric Loading 1200 FlashFoot2 7 1000 Traditional solar attachments have a horizontal offset between the rail and lag 800 FlaahFoot •Exciting Competitor bolt, which introduces leverage on the lag r6 600 bolt and decreases uplift capacity. 400 •Low-Cost Competitor FlashFoot2 is the only product to align the 200 rail and lag bolt. This concentric loading design results in a stronger attachment for 0 1 2 the system. Rail-to-Lag Offset(in) Testing & Certification Structural Certification Designed and Certified for Compliance with the International Building Code &ASCE/SEI-7. Water Seal Ratings Water Sealing Tested to UL 441 Section 27 "Rain Test" and TAS 100-95 "Wind Driven Rain Test" by Intertek. Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. UL 2703 Conforms to UL 2703 Mechanical and Bonding Requirements. See Flush Mount Install Manual for full ratings. • ®2016 IronRidge,Inc.All rights reserved.Visit www.ironridge.com or call 1-800-227-9523 for more information.Version 1.0 ���_ Datasheet IRONRIDGE Flush Mount System 14, A Built for solar's toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior Pre-stamped engineering letters structural performance. available in most states. Class A Fire Rating Design Assistant Certified to maintain the fire resistance Online software makes it simple to rating of the existing roof. create, share, and price projects. UL 2703 Listed System 25-Year Warranty Entire system and components meet Products guaranteed to be free newest effective UL 2703 standard. of impairing defects. Datasheet XR Rails O XR10 Rail XR100 Rail XR1000 Rail Bonded Splices It , , -.........„.„.....„6,..,!1_, —....„.................... —...........................t.... A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. • 6'spanning capability • 8'spanning capability • 12'spanning capability • Self-drilling screws • Moderate load capability • Heavy load capability • Extreme load capability • Varying versions for rails • Clear and black finish • Clear and black finish • Clear anodized finish • Forms secure bonding -- Clamps & Grounding C' UFOs Stopper Sleeves CAMO Grounding Lugs e �'* ww � . -dry .,« . a �._ m—_ -: . Universal Fastening Objects Snap onto the UFO to turn Bond modules to rails while Connect arrays to bond modules to rails. into a bonded end clamp. staying completely hidden. equipment ground. • Fully assembled& lubed • Bonds modules to rails • Universal end-cam clamp • Low profile • Single, universal size • Sized to match modules • Tool-less installation • Single tool installation • Clear and black finish • Clear and black finish • Fully assembled • Mounts in any direction -. Attachments O FlashFoot2 Conduit Mount Slotted L-Feet Bonding Hardware aj - A / Flash and mount XR Rails Flash and mount conduit, Drop-in design for rapid rail Bond and attach XR Rails with superior waterproofing. strut, or junction boxes. attachment. to roof attachments. • Twist-on Cap eases install • Twist-on Cap eases install Secure rail connections • T&Square Bolt options • Wind-driven rain tested • Wind-driven rain tested Slot for vertical adjusting • Nut uses 7/16"socket • Mill and black finish • Secures 3/4"or 1"conduit Clear and black finish • Assembled and lubricated Resources - __ _ Design Assistant s1£xFLPRaY NABCEP Certified Training '. Go from rough layout to fully 4' I` Earn free continuing education credits, - engineered system. For free. �INABCEP, while learning more about our systems. Go Lu 9rai it,:u, c.eorn/dtsiyn Go to IronHiage.comltraining t0 2018 IronRidge,Inc.All rights reserved.U.S.Patents:68,695,293;69,819,303;69,865,938;Others Pending.Version 1.60 ,Al_