Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (7)
IN CITY OF TIGARD MASTER PERMIT COMMUNITY DEVELOPMENT Permit#: MST2023-00282 Date Issued: 06/29/2023 T!GAR D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 2S112BD07000 Jurisdiction: Tigard Site address: 14709 SW 79TH AVE Subdivision: BRITTANY MEADOWS Lot: 6 Project: Brown Project Description: Rooftop solar PV system 11.89 kW. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $9,600.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Tvpes Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 WI Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N Other: Y Other Description: Rooftop solar array 11.89 kW Ecompasing: BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: BROWN,JAMES E&KRISTA M A AND R SOLAR CORP Required Items and Reports(Conditions) 14709 SW 79TH AVE 19636 SW 90TH CT—BLDG 4 TIGARD,OR 97224 TUALATIN,OR 97062 PHONE: PHONE: 503-420-8660 FAX: Total Fees: $356.69 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR oc9_nn1-nnin thrn AP o i'U11ltnon V nhtnin a rnnv of the rulnc nr riirunt nuoetinne In()1 INC'.by nnllinn Aryl 919 10537 nr'I Ann 119 9'i141 Issued By: �7 Permittee Signature: 4eto iup 'aCAL'1st8/n Call 503.639�d 175 by 7:00 a.m.for the next available Inspection date. u . This permit card shall he kept in a conspicuous place on the Job site until completion of the project. Approved plans are required on the job site at the time of each Inspection. Building Permit Application Checklist One- and Two-Family Dwelling FOR OFFICE USE ONLY City of Tigard Received P:,":t,.,. Date/By 13125 SW Hall Blvd.,Tigard,OR 4. 97223 Associated permits: Phone: 503.718.2439 Fax: 503.598.1960 24-Hour Inspection Line: 503.639.4175 ❑ Electrical ❑ P] l.:r ❑ Mechamcal T 1(.1 12 l) Internet: www.tigard-or.gov ❑ Other THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ■ • • 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ El 0 3 Verification of approved plat/lot. 0 0 0 4 Fire district approval required. Name of district: ❑ ❑ 0 5 Septic system permit or authorization for remodel. Existing system capacity 8 0 ❑ 6 Sewer permit. ❑ El 7 Water district approval. 0 El 0 8 Sails report. Must carry original applicable stamp and signature on file or with application. 0 El 0 9 Erosion control 0 plan ❑permit required. include drainage-way protection,silt fence design and location of catch- ❑ ❑ ❑ basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state 0 El El building codes. Lateral design details and connections must be incorporated into the plans or on a separate fill-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if 0 ❑ 0 there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator,lot area;building coverage area;percentage of coverage;impervious area;existing structures on site:and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size 0 0 ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, El El 0 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑ 0 floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. 0 0 0 Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- El ❑ 0 prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 El El locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ El El systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. . ❑ ❑ 0 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required 0 0 0 for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or 0 0 0 architect licensed in Ore.on and shall be shown to be a p r licable to the t ro ect under review. .lt RISDICTIONAL SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 1 I"x 17". • ■ ■ 24 Two(2)sets each are required for Items 16,19,20 and 22 above. El ❑ 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. U ❑ ❑ 27 "Drawn to scale"indicates standard architect or engineer scale. El Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 El 0 including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9,1995. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Applicatiofi C E I V E D FOR OFFICE USE ONLY ErCity o Tigard l Received •ll 11.. 0// -✓ JUN N 1 5 2023 Datedi Penml N:1 1 I ` 1 13125 S W Ball Blvd.,Tigard,OR 97223 Plan Review Y 7 Phone: 503.718.2439 Fax: 503.598.1c.1s0 /�p❑n Date/B - Related Permit#: •Inspwtion Line. 503.639 4175 CITY o f T I GAR'J_ Ready Date/ny: finis: ® See Page 2 for TIG ARD. Internet: www.tigard-on.gov ,l, l �_ ./ .F�, ,1 Notified'Method Supplemental Information TYPE OF WORK PLAN REVIEW ❑New construction ❑� Addition/alteraliunireplaccmcni Please check all that apply(submit 2 sets of plans iv items checked) O Service or feeder 400 amps or mote ❑Budding over these stones ❑Demolition ❑ Other: where the available fault current 0 Manias and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. III 1-and 2-family dwelling ❑Commercial/industrial 0 Accessory building less to ground or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family 0 Master builder ❑Other: 0 Fire pump. 0 Installation of 150 KVA or JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived 0 Addition of new motor load of system. Job 4: Job site address: 14709 SW 79th Ave 100HP or more ❑"�","E","l-z","I-3", O Six or more residential units. occupancy. City/State/ZIP: "Tigard,OR 97224 ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bld /a t.#l: Project name: Brown,James 0 Hazardous locations. 0 Supply voltage for more than g P J 0 Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: - FEE SCHEDULE Desariphoe .... I Qty. I Each I Total I ' New residential single-or multi-family dwelling unit. Subdivision: Lot 4: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel 4: 2S 1 I2BD07000 Ea.add'1 500 sq.ft.or portion 33.92 1 DESCRIPTION OF WORK Limited energy,residential . -... (with above sq.ft.) 75.00 2 Rooftop install of a 11.89 KVA photovoltaic solar system Limited energy,multi-family residential(with above sq.ft.) 75.00 2 Renewable Energy ❑ See Page 2 I0 TENANT Services or feeders installation,alteration,and/or relocation Name: James Brown 200 amps or less 100.70 2 Address: 14709 SW 79th Ave 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: Tigard,OR 97224 601 amps to 1,000 amps 301.04 2 Over 1,000 amps or volts 552.26 2 Phone:( 386 ) 972-0741 Fax:( ) Temporary services or feeders installation,alteration,and/or Email: - relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature:_ Date: 401 amps to 599 amps 168.54 2 7 APPLICANT t CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name: A and R Solar SPC dba A&R Solar above service or feeder fee, 7.42 2 each branch circuit Contact name: Lara Worcester B.Fee to branch circuits without • service or feeder fee,fast 56.18 2 Address: 19636 SW 90th Ct Bldg 4 branch circuit City/State/ZIP: Tualatin,OR 97062 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(503 )420-8680 ext 4 Fax: :( ) Each manufactured or modular 67.84 2 dwelling,service and/or feeder Email: permits@a-rsolar.com Reconnect only 67.84 2 CONTRACTOR _ Pump or irrigation circle 67.84 2 Business name: A&R Solar Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy ❑ See Page 2 2 Address: 19636 SW 90th Ct Bldg 4 panel,alteration,or extension. City/State/ZIP: Tualatin,OR 97062 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:( 503 ) 420-8680 ext 4 Fax:( ) Investigation(1 hr min) 90.00/hr Email: permits@a-rsolar.com Industrial plant(1 fir min) 78.18/hr Inspections for which no fee is 90.00/lot CCB Lie.: 207641 Electrical Lie.: C1179 Suprv.Lie.: 54945 specifically listed(P hr min) OA ELECTRICAL PERMIT FEES Suprv.Electrician signature,required: '9d Y-2h___ Subtotal: $133.56 Print name: Robert Nieman Date: 6/13/2023 0 Plan Review Required(25°'o of permit fee): // � / " ' ' ".e," State surcharge(12%of permit fee): S 16.00 Authorized signature:.L a.. (�(/�2.C,4 .(.i4 TOTAL PERMIT FEE: $149.56 This permit application expires if a permit is not obtained within ISO Print name: Lars Worcester Date: 6/14/2023 days aver it has been accepted as complete. * Number of inspections allowed per permit - L:BuildmpTermits,ELC PermitApp_ELR_ERE.doc Rev 06117'2015 440-46157(I1/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Description I 121> I Each I total Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 1 133.56 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: D. Burglar Alarm 25.01 to 50 kva 301.04 2 • El Garage Door Opener* 50.01 to 100 kva 552.26 • 2 >100 kva(fee in accordance 552.26 2 with OAR 918-309-0040) ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 low: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is charged at an hourly(1 hr min) 66.25/hr I Inspections for which no fee is specifically listed('E,hr min) 90.00 hr COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES Fee for each commercial system: $75.00slowedbtot (Enter on Page1>: 133.56 OAR 918-309-0000) Number of inspectiuAu all per pemtt. Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: • Total number of commercial systems: *No licenses are required. Licenses are required for all other installations IaBsiditgrt\Permits\ELC_PamitApp_ELR ERE.doe Rev 0611712015 RE JUN 15 2023 City of Tigard BUILDING DIV SION Building Division 13125 SW Hall Blvd,Tigard,OR 97223 Phone: 503.718.2439 Fax:503.598.1960 T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 14709 SW 79th Ave City: Tigard Zip: 97224 Owner's Name: James E Brown Date: 6/13/2023 Contractor's Name: A and R Solar SPC CCB #: 207641 Design Parameters of the Property/Structure If"Yes",does not Is the installation qualify for the Flood HazardYes Located in a flood ❑ prescriptive path, follow Area plain/flood way? ® No OSSC or ORSC for design requirements. Is the wind exposure El Yes If"Yes",qualifies for Wind Exposure "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes",qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes",qualifies for structures other than ® Yes the prescriptive path. above ❑ No I:/Building/Forms/Photovoltaic-Checklist02-0I-11.docx Is the construction material wood and does ® Yes Type of If"Yes",qualifies for the construction qualify ❑ No the prescriptive path. Construction as"conventional light frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. ❑X Yes If"Yes",qualifies for the prescriptive path. ❑ No • Roof framing members Is the spacing 24 inches or less? Nominal lumber. El Yes "Yes",qualifies for Yes the prescriptive path. ❑ No Is the combined weight © Yes of the PV modules and If"Yes",qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance al Yes If"Yes",qualifies for with Section 305.4(3)of ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked,qualifies for Max.two layers the prescriptive path. X❑ of composition shingle. Is the roof mounted ❑X Yes Connections of solar assembly the solar assembly connected to roof No If e prs, p for to the roof framing or blocking the Yes p path. directly? 2 L/Building/Form s/Photo V oltai c-Checkli st02-01-11.docx Is the gauge 26 or less? ❑ Yes If"Yes",qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes",qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes",qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches,qualifies for the standing seam prescriptive path. metal panels If the width of the panel P Width of roofing is less than 18 inches, panels? 18 inches or less qualifies for the inches prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes",qualifies for fastener? El Yes the prescriptive path. ❑ No Is the roof decking of WSP min. 1/2"thickness, ❑ Yes decking connected to If"Yes",qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes",qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 l:i Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines,and,as applicable,flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x I 1 inches. . Attach a simple structural plan showing the roof framing(rafter size,type,and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 1 I inches. PV Modules Manufacturer: REC Solar Model Number: REC41OAA Pure Listing Agency: IEC 61215:2016,IEC 61730:2016,UL 61730 4 I:Building/Forms/Photovoltaic-Checklist02-01-11.docx