Loading...
HomeMy WebLinkAboutPermit Support Document (40) rP32o23- od I oc� hat, akeview ., R L Lake OswegoBlvd,ORSuite 97031005 (503)627-0100 OFFICE ���� AUG 2 2 2023 CCB#135901 ifollitorBUCITY FILDING DI DIVISION CORPORATION Hermoso — Mixed Use 7460 SW Hermosa Way Portland, OR 97223 FIRE ALARM SYSTEM ikt 5863 Lakeview Blvd.,Suite 100 po Lake Oswego,OR 97035 (503)627-0100 CCB#135901 Monitor CORPORATION TABLE OF CONTENTS A. Fire Alarm System 1) Notifier NFW-100X—Fire Alarm Control Panel 3 2) Notifier PWRWOD24—Power Expander Module 3 3) Notifier N-ANN-80—Annunciator Panel 7 4) Notifier PSE-6/10—NAC Power Supply 8 5) Napco SLE-LTEVI-FIRE—Cellular Dialer 11 6) Notifier NMM-100P—Addressable Input Module -Mini 13 7) Notifier NC-100R—Addressable Output Module 17 8) Notifier NOT-BG12LX—Addressable Manual Pull Station 19 9) Notifier NP-200—Photoelectric Smoke Detector 21 10)Notifier NH-200—Fixed Heat Detector 24 11)System Sensor P2WL—Wall Mount Horn Strobe,White 27 12)System Sensor SWL—Wall Mount Strobe, White 27 13)System Sensor PC2WL—Ceiling Mount Horn Strobe, White 31 14)System Sensor P2RK—Wall Mount Weatherproof Horn Strobe, Red 35 15)System Sensor HWL-LF—Wall Mount Low Frequency Horn, White 39 16)System Sensor P2WL-LF—Wall Mount Low Frequency Horn Strobe, White 42 17)Space Age SSU00689—Document Enclosure W/Interal Flash Storage 45 NOTIFIER ' by Honeywell NFW-100X Intelligent Addressable FACP with Communicator General The FireWarden-100X(NFW-100X)is the latest intelligent address- able Fire Alarm Control Panel(FACP)within the FireWarden Series and is a direct replacement for the FireWarden-100(NFW-100).The NFW-100X comes with a pre-installed communicator and supports up to 198 addressable devices(99 detectors and 99 modules).With erw-100% an extensive list of powerful features, the NFW-10OX programs just like FireWarden-100 products, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) o• ,w l communicator.The POTS transmits system status(alarms,troubles, " jztarli AC loss,etc.)to a Central Station via the public switched telephone rf '= network.The IP communicator's internet monitoring capability sends @ •••� alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines.Although not required, the second- ary telephone line may be retained providing backup communication I over the public switched telephone line.Optional cellular reporting is available using the CELL-MOD or CELL-CAB-N. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port(and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file,walk-test data, current status and system volt- ages by means of a USB flash drive. • Maintenance alert warns when smoke detector dust accumula- The power supply and all electronics are contained on a circuit tion is excessive board supported on a new quick install chassis and housed in a • One-person audible or silent walk test with walk-test log and metal cabinet. Available accessories include local and remote printout upload/download software,remote annunciators, and reverse polar- • System alarm verification selection per detector point ity/city box transmitter(4XTM). • PAS (Positive Alarm Sequence)and Pre-signal per point(NFPA Features 72 compliant) • Up to 16 ANN-BUS annunciators-8 per each ANN-Bus • Listed to UL Standard 864, 10th edition • Remote Acknowledge, Alarm Silence, Reset and Drill via • Pre-installed IPOTS-COM Ethernet IP and POTS(Plain Old Tele- addressable modules or remote annunciator phone Service)Central Station Communicator over AlarmNet • Upload/Download of program and data via USB with optional FS-. • Optional CELL-MOD or CELL-CAB-N GSM Central Station Com- Tools Programming Utility mu nicator over AlarmNet® • Automated activation of the NFC-50/100 Emergency Command SLC COMMUNICATION LOOP Center • Supports FlashScan®and CLIP protocols • NFC-FFT Firefighter Telephone option • SLC operates up to 10,000 ft.(3,000 m)in FlashScan mode with • Compatible with SWIFT®wireless devices twisted,unshielded wire • Auto-programming (learn mode) reduces installation time. • Single addressable SLC loop which meets NFPA Class B and Reports two devices set to the same address • Four built-in, independently programmable Style Z (Class A) or Class A requirements Style Y(Class B)NAC circuits • 198 addressable device capacity(99 addressable detectors and • Selectable strobe synchronization for System Sensor,Wheelock, 99 modules) and Gentex devices • Compatible with NOTIFIER FireWarden and ONYX Series • Notification Appliance Circuit End of Line resistor matching addressable devices (refer to the FireWarden SLC Wiring Man- • Four programmable function keys for ease of maintenance ual) • Two programmable relays and one fixed trouble relay NOTIFICATION APPLIANCE CIRCUITS(NACS) • Built-in Programmer • Integral 80-character LCD display with backlighting • Four independently programmable output circuits.Circuits can be • Real-time clock/calendar with automatic daylight savings control configured for the following outputs: • History file with 1,000 event capacity —Style Y(Class B) • Addressable sounder base compatibility —Style Z(Class A) • Control module delay timer • Silence Inhibit and Autosilence timer options • Automatic detector sensitivity testing(NFPA 72 compliant) • Continuous, March Time, Temporal, or California code for main • Automatic device type-code verification circuit board NACs with two-stage capability • Point trouble identification • Waterfiow selection per module point• • Selectable strobe synchronization per NAC • Alarm verification selection per detector point • 2.5 A special application,250mA regulated,total power for NACs NOTE:Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A DN-60959:C•7/16/2018—Page 1 of 4 PROGRAMMING AND SOFTWARE vised output for local energy municipal box transmitter, alarm and • Autoprogramming(learn mode)reduces installation time trouble. Includes a disable switch and disable trouble LED. • Custom English labels (per point) may be manually entered or PWRMOD24 Power Expander Module: Optional power module. selected from an internal library file Increases alarm power output to 6 amps. • Two programmable Form-C relay outputs COMPATIBLE ANNUNCIATORS • 99 software zones N-ANN-80: Remote LCD annunciator mimics the information dis- • Continuous fire protection during online programming played on the FACP LCD display. Recommended wire type is un- • Program Check automatically catches common errors not linked shielded. (Basic model is black;order-W for white;see DN-7114.) to any zone or input point N-ANN-100R: Remote LCD annunciator mimics the information dis- • OFFLINE PROGRAMMING: Create the entire program in your played on the FACP LCD display. Recommended wire type is un- office using FS-Tools,a Windows®-based software package,and shielded. For use in FM applications only. (Basic model is black; upload/download system programming locally. Offline program- order R for red.) ming requires an ethernet connection. FS-Tools is available on N-ANN-I/O:LED Driver Module provides connections to a user sup- www.notifier.com. plied graphic annunciator.(See DN-7105.) N-ANN-LED: Annunciator Module provides three LEDs for each User interface zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. LED INDICATORS (See DN-60242.) • Fire Alarm(red) • CO Alarm(red) N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points.(See DN-60242.) • AC Power(green) • Supervisory(yellow) N-ANN-RLY: Relay Module provides 10 programmable Form-C • Trouble(yellow) • Ground fault(yellow) relays.Can be mounted inside the cabinet.(See DN-7107.) • Battery fault(yellow) • Disabled(yellow) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a • Maintenance(yellow) Communication(yellow) connection for a serial or parallel printer.(See DN-7103.) • Alarm Silenced(yellow) • F1-F4 Programmable Function ADDRESSABLE DEVICES Keys(yellow) FSP-951: Addressable low-profile photoelectric smoke detector. FlashScan only. KEYPAD FSP-951-IV:Addressable low-profile photoelectric smoke detector. • 16 key alpha-numeric pad • Acknowledge Ivory.FlashScan and CLIP mode. • Alarm Silence • Drill(Manual Evacuate) NP-200: Addressable low-profile photoelectric smoke detector. • Four(4)programmable function keys• Reset(lamp test) B300-6 base included,FlashScan only. PRODUCT LINE INFORMATION NP-200-IV: Addressable low-profile photoelectric smoke detector. Ivory,B300-6-IV base included.FlashScan and CLIP mode. NFW-100X: Addressable Fire Alarm Control Panel with one SLC FSP-951T: Addressable low-profile photoelectric smoke detector loop. Includes main circuit board with display chassis with trans- with thermal sensor. FlashScan only. former, backbox with door, plastic bag containing screws, cables, FSP-951T-IV:Addressable low-profile photoelectric smoke detector key,etc. with thermal sensor. Ivory. FlashScan and CLIP mode. FS-Tools: Programming software for Windows®-based PC com- NP-200T:Addressable low-profile photoelectric smoke detector with puler.Available for download at www.notifier.com. thermal sensor.B300-6 base included.FlashScan only. CELL CAB-N/CELL-MOD:Optional GSM communicators. NP-200T-IV:Addressable low-profile photoelectric smoke detector IPOTS-COM: Dual technology (POTS and IP) communicator. with thermal sensor. Ivory,B300-6-IV base included.FlashScan and (replacement board) CLIP mode. DP-ES-R:Optional dress panel for the NEW-100X(red). FSP-951 R: Remote test capable addressable photoelectric smoke DP-ES-B:Optional dress panel for NFW-100X(black). detector for use with DNR(W) duct detector housing. FlashScan TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For only. red,order TR-CE.) FSP-951R-IV: Remote test capable addressable photoelectric BB-XP:Optional cabinet for one or two modules. smoke detector for use with DNR(W) duct detector housing. Ivory. BB-25: Optional cabinet for up to six modules mounted on CHS-6 FlashScan and CLIP mode. chassis. NP-200R: Remote test capable addressable photoelectric smoke BB-26:Battery backbox,holds up to two 25 AH batteries and CHG- detector for use with DNR(W) duct detector housing. FlashScan 75. only. NFS-LBB:Battery box,houses two 55 AH batteries NP-200R-IV:Remote test capable addressable photoelectric smoke CHS-6:Chassis,mounts up to six multi-modules in a BB-25 cabinet. detector for use with DNR(W)duct detector housing. Ivory, FlashS- CHG-75:Battery charger for lead-acid batteries with a rating of 25 to can and CLIP mode. 75 AH. FST-951: Low-profile 135°F fixed thermal sensor.FlashScan only. CHG-120: Remote battery charging system for lead-acid batteries FST-951-IV: Low-profile 135°F fixed thermal sensor. Ivory. FlashS- with a rating of 55 to 120 AH. Requires additional NFS-LBB for can and CLIP mode. mounting. NH-200: Low-profile 135°F fixed thermal sensor. B300-6 base NOTE:CHG-120 or CHG-75 required for batteries larger than 18AH. included,FlashScan only. BAT Series:Batteries,see data sheet DN-6933. NH-200-IV:Low-profile 135°F fixed thermal sensor. Ivory. B300-6-IV PRN Series: UL listed compatible event printer. Uses tractor-fed base included, FlashScan and CLIP mode. paper. FST-951R: Low-profile, intelligent, rate-of-rise thermal sensor. OPTIONAL MODULES FlashScan only. FST-951R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. 4XTM Reverse Polarity Transmitter Module: Provides a super- Ivory. FlashScan and CLIP mode. Page 2 of 4—DN-60959:C•7/16/2018 NH-200R: Low-profile 135°F fixed thermal sensor. B300-6 base zone of conventional two-wire detectors. Requires resettable 24 included, FlashScan only. VDC power. Refer to the Device Compatibility Document for listed NH-200R-IV: Low-profile 135°F fixed thermal sensor.Ivory. B300-6- compatible devices and quantity limitation. IV base included,FlashScan and CLIP mode. NZM-100:Similar to NMM-100.Addressable Monitor Module for one FST-951H: Low-profile intelligent 190°F/88°C fixed thermal sensor. zone of conventional two-wire detectors. Requires resettable 24 FlashScan only. VDC power. Refer to the Device Compatibility Document for listed FST-951H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- compatible devices and quantity limitation. sor.Ivory. FlashScan and CLIP mode. FCM-1;Addressable Control Module for one Style Y/Z (Class B/A) NH-200H: Low-profile intelligent 190"F/88°C fixed thermal sensor. zone of supervised polarized Notification Appliances. Mounts 6 base included,FlashScan only. directly to a 4.0" (10.16 cm.) electrical box. NAC option requires B300external 24 VDC to power notification appliances. NH-200H-IV: Low-profile intelligent 190Fl88°C fixed thermal sen- NC-100:Addressable Control Module for one Style VIZ(Class B/A) sor. Ivory.B300-6-IV base included,FlashScan and CLIP mode. zone of supervised polarized Notification Appliances. Mounts Legacy Devices directly to a 4.0" (10.16 cm.) electrical box. NAC option requires FSI-851:Addressable low-profile ionization smoke detector. external 24 VDC to power notification appliances. NI-100:Addressable low-profile ionization smoke detector. FRM-1: Addressable relay module containing two isolated sets of FSP-851:Addressable low-profile photoelectric smoke detector. Form-C contacts,which operate as a DPDT switch. Mounts directly NP-100:Addressable low-profile photoelectric smoke detector. to a 4.0"(10.16 cm.)box,surface mount using the SMB500. FSP-851T: Addressable low-profile photoelectric smoke detector NC-100R:Addressable relay module containing two isolated sets of with thermal sensor. Form-C contacts,which operate as a DPDT switch. Mounts directly to a 4.0"(10.16 cm.)box,surface mount using the SMB500. NP-100T:Addressable low-profile photoelectric smoke detector with NBG-12LX: Addressable manual pull station with interface module thermal sensor. mounted inside. FSP-851R: Remote test capable addressable photoelectric smoke NOT-BG12LX:Addressable manual pull station with interface mod- detector for use with DNR(W)duct detector housing. ule mounted inside. NP-100R: Remote test capable addressable photoelectric smoke ISO-X:Fault Isolator Module. detector for use with DNR(W)duct detector housing. FST-851:Fast-response,low-profile heat detector. N100-ISO:Fault Isolator Module. NH-100: Fast-response,low-profile heat detector. ISO-6: Six-fault isolator module.Mount one or two modules in a BB- XP cabinet(optional). Mount up to six modules on a CHS-6 chassis FST-851 R: Fast-response,low-profile heat detector with rate-of-rise in a CAB-3/CAB-4 series cabinet. option. SMB500: Used to mount all modules except the FMM-101lNMM- NH-100R: Fast-response, low-profile heat detector with rate-of-rise 100P. option. NMM-100-10:Ten-input monitor module.Mount one or two modules FST-851 H: Fast-response,low-profile heat detector that activates at in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 190"F/88°C. chassis in a BB-6F cabinet. NH-100H: Fast-response, low-profile heat detector that activates at NZM-100-6: Six-zone interface module. Mount one or two modules 190°F/88°C. in a BB-XP cabinet(optional). Mount up to six modules on a CHS-6 FAPT-851:Addressable low-profile multi-sensor detector. chassis in a CAB-3/CAB-4 series cabinet. NP-A100:Addressable low-profile multi-sensor detector. SWIFT Wireless Devices B200S: Programmable,addressable sounder base. FWSG:Wireless Gateway B200SR:Addressable sounder base. FWD-200P:intelligent,wireless photo detector. DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order FWH-200R0R135: LiteSpeed intelligent wireless rate of rise(135°) FSP-851R,FSP-951R,or NP-100R separately.) heat detector. DNRW: InnovairFlex low-flow non-relay duct-detector housing, with FWD-200ACCLIMATE:Wireless Acclimate Detector NEMA-4 rating. Watertight. (Order FSP-851R, FSP-951R, or FWH-200FIX135: intelligent wireless fixed-temperature (135°)heat NP-100R separately.) detector. Addressable Modules FW-MM: Intelligent wireless monitor module. FMM-1:Addressable Monitor Module for one zone of normally-open FW-RM:Intelligent wireless relay module. dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) NBG-12LW:Intelligent wireless pull station. box. Includes plastic cover plate and end-of-line resistor. Module WAV-RL,WAV-WL,WAV-CRL,WAV-CWL: Intelligent AV bases. may be configured for either a Style B(Class B)or Style D(Class A) W-USB: Wireless USB radio/antenna dongle that plugs into the IDC. USB port of a PC running SWIFT Tools. NMM-100: Addressable Monitor Module for one zone of normally- SWIFT Tools: Programming and diagnostic utility for the Wireless open dry-contact initiating devices. Mounts in standard 4.0" (10.16 Gateway and devices.Available for download from firelite.com. cm.)box. Includes plastic cover plate and end-of-line resistor. Mod- NOTE: For more information on Compatible Addressable Devices for ule may be configured for either a Style B(Class B)or Style D(Class use with the Fire Warden-100X,see the following data sheets(document A)IDC. numbers): NP-200 Series (DN-60979), NH-200 Series (DN-60980), FDM-1:Dual Monitor Module.Same as NMM-100 except it provides FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 two Style B(Class B)only IDCs. Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), NDM-100: Dual Monitor Module. Same as NMM-100 except it pro- N100-ISO(DN-6994),NP-100 series(DN-6995),NH-100/NH-100R(ON- vides two Style B(Class B)only IDCs. 6997), DNR/InnovairFlex(DN-60424, DN-60429), NP-A100 (DN-6998), NMM-100/NMM-100P/NDM-100/NZM-100 (DN-6999), NC-100 (ON- FMM-101: Miniature version of NMM-100. Excludes LED and Style 7000), NC-100R (DN-60383), NMM-100-10 (DN-6990), MM-1/FDM-1/ D option.Connects with wire pigtails.May mount in device backbox. FZM-1/FMM-101 (DN-6720), FCM-1/FRM-1 (DN-6724), NOT-BG12LX NMM-100P:Miniature version of NMM-100.Excludes LED and Style (ON-7001), NBG-12LX (DN-6726), and FireWarden SLC Manual D option.Connects with wire pigtails.May mount in device backbox. (52304). FZM-1: Similar to NMM-100. Addressable Monitor Module for one DN-60959:C•7/16/2018—Page 3 of 4 SPECIFICATIONS System Capacity Addressable Device Accessories • Intelligent Signaling Line Circuits 1 End-of-Line Resistor Assembly (R-47K and R-3.9K): The • Addressable device capacity 198 47k ohm assembly supervises the NMM-100-10, NDM-100, NMM- • Programmable software zones 99 100P, and NC-100 module circuits.The 3.9k ohm assembly super- vises the NZM-100-6 module circuit. These resistors are included • Annunciators 16 with each module. Power Supervision Relay: Supervises the power to 4-wire smoke Electrical Specifications detectors and notification appliances. AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, Wiring Requirements auto-sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger ence.Refer to the panel manual for wiring details. Capacity: 7-18 AH (FireWarden-100X cabinet holds maximum of two 18 AH batteries.) NFPA Standards Communication Loop: Supervised and power-limited. The FireWarden-100X complies with the following NFPA 72 Fire Notification Appliance Circuits: Terminal Block provides connec- Alarm Systems requirements: tions for four NACs, Style Y(Class B)or Style Z(Class A). Special —LOCAL(Automatic, Manual, Waterflow and Sprinkler Supervi- Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA sory). regulated. End-of-Line Resistor: 4.7k ohm, '% watt (P/N 71252 UL —AUXILIARY (Automatic, Manual and Waterflow) (requires listed)for Style Y(Class B)NAC;system capable of 1.9 kf2-22 kf 4XTM). ELR range. Refer to the NOTIFIER Device Compatibility Document —REMOTE STATION (Automatic, Manual and Waterflow) for listed compatible devices. (Where a DACT is not accepted,the alarm,trouble and supervi- Two Programmable Relays and One Fixed Trouble Relay: Con- sory relays may be connected to UL 864 listed transmitters.For tact rating:2.0 A @ 30 VDC(resistive), 0.5 A @ 30 VAC(resistive). reverse polarity signaling of alarm and trouble, 4XTM is Form-C relays,non-power-limited,non-supervised. required.) —PROPRIETARY(Automatic,Manual and Waterflow). Cabinet Specifications -CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" —OT, PSDN (Other Technologies, Packet-switched Data Net- (1.82 cm.)deep.Backbox: 19.00"(48.26 cm.)high x 16.65"(42.29 work) cm.)wide x 5.25" (13.34 cm.)deep. Trim Ring (TR-CE/B): 22.00" (55.88 cm.)high x 19.65"(49.91 cm.)wide. —IBC 2012,IBC 2009, IBC 2006,IBC 2003,IBC 2000(Seismic). —CBC 2007(Seismic) Shipping Specifications Weight: 26.9 lbs. (12.20 kg.)Dimensions:20.00"(50.80 cm.)high Agency Listings and Approvals x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. The listings and approvals below apply to the basic FireWarden- 100X control panel. In some cases, certain modules may not be Temperature and Humidity Ranges listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. This system meets NFPA requirements for operation at 0—49°C/32 —120°F and at a relative humidity 93%±2%RH(noncondensing)at • UL:S635 32°C t 2°C (90°F is 3°F). However, the useful life of the system's • CSFM:7165-0028:0505 standby batteries and the electronic components may be adversely • FDNY:COA#6268 affected by extreme temperature ranges and humidity.Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15—27°C/60— 80°F. IS® ffillefiliNSIMMOttiffin SHIFTY SYSTEMS This document is not intended to be used for installation purposes. We by to keep our prodtd information up-to-date and accurate. We cannot cover all specific appliraaons or anticipate all requirements. All specifications are subject to change without notice aarmNet®,NOTIFIER®,FireWarden®,SWIFT®,and System Sens*W NOTIFIER are registered trademarks of Honeywell International Inc.Microsoft®and 12 Clintonville Road Window*are registeredtrademarksof the Microsoft corporanon. ®Northford,CT 06472 02018 by Honeywell Intemabgral Inc.al tights reserved.Unauthorized NOTIFIER,, 203.484.7161 use of this document Is stricty prohibited. www.nofi£er.com Country of Origin:USA by Honeywell til✓ NOTIFIER by Honeywell N-ANN-80 80-Character Serial LCD Annunciator General The N-ANN-80 annunciator is a compact,backlit,80-character LCD * , P,« fire annunciator that mimics the Fire Alarm Control Panel (FACP) ` s display. It provides system status indicators for AC Power,Alarm, as Trouble, Supervisory, and Alarm Silenced conditions. The N-ANN- ,r--�" ,R 80 and the FACP communicate over a two-wire serial interface 'r employing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a wires, . remote UL-listed, filtered power supply.The N-ANN-80 is black; for white order N-ANN-80-W. ®11 • v The N-ANN 80 displays English-language text of system point infor- mation including device type,zone,independent point alarm,trouble NOTI FI ER 1 or supervisory status, as well as anycustom alpha labels °'P ry P Pro- J er H'aywei grammed into the control panel. It includes control switches for VI ^r A remote control of critical system functions. (A keyswitch prevents "- " unauthorized operation of the control switches.) . ---Up to eight N-ANN-80s may be connected to the ANN-Bus of each FACP. Minimal programming is required, which saves time during system commissioning. The N-ANN-80 is compatible with NOTI- FIER FACPs with an ANN-Bus,such as the NFW-50X. Features • Trouble • Listed to UL Standard 864,9th Edition • Supervisory • Backlit 80-character LCD display(20 characters x 4 lines) • Alarm Silenced • Mimics all display information from the host panel • Control switches for System Acknowledge, Signal Silence, Drill, Specifications and Reset • Operating voltage range: 18 VDC to 28 VDC • Control switches can be independently enabled or disabled at the • Current consumption © 24 VDC nominal (filtered and non- FACP resettable):40 mA maximum • Keyswitch enables/disables control switches and mechanically • Ambient temperature:32°F to 120°F(0°C to 49°C) locks annunciator enclosure • Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± • Keyswitch can be enabled or disabled at the FACP 2°C(90°F±3°F) • Enclosure supervised for tamper • 5.375"(13.65 cm.)high x 6.875"(17.46 cm.)wide x 1.375"(3.49 • System status LEDs for AC Power,Alarm,Trouble, Supervisory, cm.)deep and Alarm Silence • For use indoors in a dry location • Local sounder can be enabled or disabled at the FACP • All connections are power-limited and supervised • N-ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming The ANN-Bus • Displays device type identifiers, individual point alarm, trouble, supervisory,zone,and custom alpha labels POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- • Time-and date display field !ARV POWER SUPPLY • Surface mount directly to wall or to single, double, or 4" square The ANN-Bus can be powered by an auxiliary power supply when electrical box the maximum number of ANN-Bus devices exceeds the ANN-Bus • Semi-Flush mount to single, double, or 4" square electrical box. power requirements.See the FACP manual for more information. Use ANN-SB80KIT for angled view mounting ANN-BUS DEVICE ADDRESSING • Can be remotely located up to 6,000 feet (1,800 m) from the Each ANN-Bus device requires a unique address (ID Number) in panel order to communicate with the FACP.A maximum of 8 devices can • Backlight turns off during AC loss to conserve battery power but be connected to the FACP ANN-Bus communication circuit.See the will turn back on if an alarm condition occurs FACP manual for more information. • May be powered by 24 VDC from the host FACP or by remote WIRE REQUIREMENTS:COMMUNICATIONS CIRCUIT power supply(requires 24 VDC) • Up to eight N-ANN SOs can be connected on the ANN-Bus The N-ANN-80 connects to the FACP ANN-Bus communications cir- cuit.To determine the type of wire and the maximum wiring distance Controls and Indicators that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total worst case current draw for all modules • AC Power on a single 4-conductor bus. The total worst case current draw is • Alarm calculated by adding the individual worst case currents for each module. DN-7114:D•3/15/2018—Page 1 of 2 NOTE:For total worst case current draw on a single ANN-Bus refer to Agency Listings and Approvals appropriate FACP manual. The listings and approvals below apply to the N-ANN-80. In some WIRE REQUIREMENTS:POWER CIRCUIT cases, certain modules may not be listed by certain approval agen- • 14 to 18 AWG(0.75-2.08 mm2)wire for 24 VDC power circuit is cies, or listing may be in process. Consult factory for latest listing acceptable. status. • All connections are power-limited and supervised. • UL:S635 • A maximum of eight N-ANN-80 modules may be connected to • FM approved this circuit. • CSFM:7120-0028:0240 • MEA:442-06-E Vol.2 Ordering Options: N-ANN-80:Black 80 character LCD Annunciator. N-ANN-80-W:White.80 character LCD Annunciator. ANN-SB8OKIT-B: Black surface mount backbox with angled wedge. ANN-SB8OKIT-W: White surface mount backbox with angled wedge. IS® eett€EMNI E MMIMELIIIIti QUALITY SYSTEMS This document is not intended lobe used fa installation purposes. We by to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. N OTI F I E R al specrficotions are subject to charge without notice. 12 Clintonville Road NOTIFIER®is a registered trademark of Honeywell International Inc. Northford,CT 06472 C2018 by Honeywell International Inc.All rights reserved.Unauthorized N O1' F' E Rvr 203.484.7161 use of this document is strictly prohibited. www.notifier.com Country of Origin.USA by Honeywell ,„, StarLink ILF ` Commercial Fire Alarm Cellular &/or IP COMMERCIAL FIRE CELLU AR&°IP Fire Alarm LTE Communicators StarLink Fire Specifications Ordering Information STANDARD MODELS: COMMERCIAL FIRE SOLE PATH CELLULAR& • Advanced LTE Dual Diversity Antennae for optimized DUAL PATH CELLULAR&/OR IP("I"MODELS):* performance SLE-LTEVI-FIRE Dual Path Communicator,Cellular&/or IP, • Durable ABS plastic housing includes three keyhole slots for connected by Verizon LTE',ABS.Low current draw,panel- mounting(for commercial application,aligns with triple gang powered technology'(powered by control panel) boxes) SLE-LTEV-FIRE as above, but sole path cellular model • Panel Powered Technology"(powered by panel),Low current SLELTEVI-CFB Commercial Fire Dual Path Mercantile model draw,71 mA standby,200mA transmit in red metal housing on LTE,Verizon LTE Network,powered • Dimensions:5-3/8"x 7-7/8"x 1-7/8"(HxWxD) directly from control panel • Weight:13.5 oz SLETEVI-CFB-PS Commercial Fire Dual Path Mercantile model • 3 LED Indicators-Green,Signal Strength;Amber-Busy/ in red metal housing,LTE,Verizon LTE Network. Direct 120VAC Activation;Red-Trouble Powered(w/provisions for backup battery/charger).Or, • Patented Signal BoostTM'signal amplification circuit and high- Optional TRF12plug-in transformer may be used,where codes gain performance antennae permit • Operating Environment:0 to 49°C(32-120°F),up to 93% ACCESSORIES: YY`N.—, `••-- "* humidity(non-condensing) Free Commercial Fire Tradeup Trifold AJ � • 12V-24V Universal FACP Support,auto-current sensing. Brochures/Mailers/Stuffers(A720)for new Support all brands communicating in Contact ID and 4/2 and existing fire accounts �eiy SLE-ANTEXT75 Optional extended antenna with ' �_"`"- '•'- MERCANTILE MODELS(similar to above,with): 75'cable(new conical shape) • Locking Metal Enclosure with Hinged door& 2 key-slots for SLE-ANTEXT50 As above,with 50'cable -Likli ill wall mounting(LED indicators,inside) SLE-ANTEXT30 As above,with 30'cable • Dimensions: 9-5/8"x 11-3/4"x 3-3/8"D(HxWxD) SLE-DLEXT Optional,as above,for downloading,extends distance • Weight:8 lbs(max.,power supply models) to Napco panel up to 100' • Electrical Ratings for 120VAC,60Hz TRF12 Optional Plug in AC Transformer,16.5V/20VA(use is • For Models with Power Supply: subject to local code compliance) • Input Voltage: 120VAC Nominal SLE-DLCBL Optional High-Speed Napco Panel Up/download cable • Input Current:400mA maximum • Maximum Charging Current: 200mA • Electrical Ratings for g New! FireLink"" Integrated Fire Alarm Control • For Models without Power Supply: Panel w/StarLink Fire LTE Built In • Input Voltage: 11-15VDC(power-limited output from listed Award Winning FL-FACP-LTEVS control panel) ems: Firewolf 8 Zone 24V Conventional • Input Current:71 mAwith peak RFtransmission current of °'° { commercial Fire Alarm control Panel with onboard StarLink Fire° 200mA " Sole Path,Verizon LTE Cellular • Electrical Ratings for the IN 1 Burg/Fire Input: ' Alarm Communicator and integral menu-driven LCD annunciator,w/ • Input Voltage:9-15VDC s 4amp,24V power supply.Optionally • Maximum Input Current Up to 2mA from FACP NAC circuit ! expandable up to 32 points/zones via _,� commercial addressable,wireless or • Electrical Ratings for IN 2 and IN 3: _wooi `. L,rdys conventional fire devices(2 onboard ' f k NACs providing up to 4A notification • Maximum Loop Voltage:1 SVDC sx. / „' ..- power).Locking,mercantile red • Maximum Loop Current 1.2mA endosure,(surface or flush mount') »- ••�*•, removable 16"x17"door with • Electrical Ratings for 3 PGM Outputs: '•r` 14.25"x16"base.Houses 16Ah battery backup • Open Collector Outputs: Maximum voltage 3V when active; 15V maximum when not active T H � • Maximum PGM Sink Current:50mA mount Starlink Fire • Operating Environment 0 to 49°C(32-120°F),up to 93% ^ne° humidity(non-condensing) COMMERCIAL FIRE CELLULAR&IP • 12V-24V Universal FACP Support,auto-current sensing. 333 800-Bayv6 w Ave.,Amityville,1l6, 1-NY 89-911701 USA ` `,Pp g 1-800 645-9445 •Fax:1-631-789-9292 NFP/1 Support all brands communicating in Contact ID and 4/2 www.napcosecurity.com SerLinkSUNnkPoe,Frelink,SignalBoost PandPowe ed-echnologi,Gemini&Gemhi CanmeroalaretrademarleofNapm.Veriion,LTE.elc are tademarladtheir respeeoseompanles'Starlinkoffers(ulldata coverage in US ksm*tuatyaipanelbrandsreporlinginContaalDor4/2. (a MdedkmtlteYaAAtonleupincenaxseecrine uncer hapPwnwnapmmidymN9adinWsnink4g4FOale/tRpnoArca°dwrtew/opriormtice LTE ifespandaimsarebasoiontlwsedonine Weimeranlann based aidie RoolMeticslISItOonalRootSwe Repot 1H2O17. ONAPCO,NAPCO Security Technologies Inc(NASDAQ:NSSC) A734 2018.9 DN-6999:C Monitor Modules NMM-100(A), NMM-1 OOP(A), NOTE F I E R NZM-100(A), and NDM-100(A) for FireWarden Series Panels by Honeywell Intelligent Addressable Devices General Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact , ,input devices, such as conventional heat detectors and pull 11, stations, or monitor and power a circuit of two-wire smoke detectors(NZM-100(A)). NMM-100(A)is a standard-sized module(typically mounts to a [' 4" [10.16 cm] square box) that supervises either a Style D y (Class A) or Style B (Class B) circuit of dry-contact input devices. ,.°,,, NMM-100P(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input - devices. Its compact design allows the NMM-100P(A) to be t' mounted in a single-gang box behind the device it monitors. 4116 gib • J $ NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire,24 volt,smoke detectors on a Style D(Class A) or Style B(Class B)circuit. NDM-100(A) is a standard-sized dual monitor module that NMM-100(A)(Type H) monitors and supervises two independent two-wire Style B (Class B) dry-contact initialing device circuits (IDCs) at two separate,consecutive addresses in intelligent,two-wire systems. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module NMM-1 00(A) Monitor Module addresses on an SLC loop. It responds to regular polls from • Built-in type identification automatically identifies this device the control panel and reports its type and the status(open/nor- as a monitor module to the control panel, mal/short) of its Initiating Device Circuit(IDC).A flashing LED indicates that the module is in communication with the control • Powered directly by two-wire SLC loop.No additional power panel. The LED latches steady on alarm (subject to current required. limitations on the loop). • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. NMM-100(A) SPECIFICATIONS • Direct Decade entry of address: 01 -99 on FireWarden- Nominal operating voltage: 15 to 32 VDC. 100-2,01 -50 on FireWarden-50. Maximum current draw:5.0 mA(LED on). • LED flashes during normal operation and latches on steady Average operating current: 350 pA (LED flashing), 1 corn- to indicate alarm. munication every 5 seconds,47k EOL. The NMM-100(A) Monitor Module is intended for use in intelli- Maximum IDC wiring resistance:40 ohms. gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- EOL resistance:47K ohms. vides either a two-wire or four-wire fault-tolerant Initiating Temperature range:32°F to 120°F(0°C to 49°C). Device Circuit (IDC)for normally-open-contact fire alarm and Humidity range: 10%to 93%noncondensing. supervisory devices. The module has a panel-controlled LED indicator. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x NMM-100(A)APPLICATIONS 2.125"(5.398 cm)deep box. Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B(Class B)or Style D(Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. DN-6999:C•10/06/2010—Page 1 of 4 NMM-100P(A) Mini Monitor Module Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x • Built-in type identification automatically identifies this device 0.65"(1.651 cm)deep. as a monitor module to the panel. Wire length:6"(15.24 cm)minimum. • Powered directly by two-wire SLC loop.No additional power required. NZM-100(A) Interface Module • High noise(EMF/RFI)immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct Decade entry of address: 01 — 99 on FireWarden- source. 100-2,01 —50 on FireWarden-50. • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. g 1415 0 1 ADDRESS 0 1 • Direct Decade entry of address:, 01 —99 on FireWarden- a 13 %//J 2 2 100-2,01 —50 on FireWarden-50. 49 4 LOOP 4 LED flashes during normal operation. 10 5 '��j�// 5 • LED latches steady to indicate alarm on command from 9 8 7 6 9 6 control panel. 8 7 TENS ONES The NZM-100(A)Interface Module is intended for use in intelli- i n , gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors.It transmits the status(nor- O W p Y mal,open,or alarm)of one full zone of conventional detectors 0 � 0 ¢ back to the control panel. All two-wire detectors being moni- j m tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke ) I I detectors. The monitored circuit may be wired as an NFPA Style B(Class B)or Style D(Class A) Initiating Device Circuit. The NMM-100P(A) Mini Monitor Module can be installed in a A 3.9 K ohm End-of-Line Resistor (provided) terminates the single-gang junction directly behind the monitored unit. Its end of the Style B or D (class B or A)circuit (maximum IDC small size and light weight allow it to be installed without rigid loop resistance is 25 ohms). Install ELR across terminals 8 mounting.The NMM-100P(A)is intended for use in intelligent, and 9 for Style D application. two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- NZM-100(A)OPERATION ing device circuit for normally-open-contact fire alarm and Each NZM-100(A) uses one of the available module security devices. NMM-100P(A) addresses on an SLC loop. It responds to regular polls from NMM-100P(A)APPLICATIONS the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC).A flashing LED Use to monitor a single device or a zone of four-wire smoke indicates that the module is in communication with the control detectors,manual fire alarm pull stations,waterfiow devices,or panel. The LED latches steady on alarm (subject to current other normally-open dry-contact devices. May also be used to limitations on the loop). monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device NZM-100(A)SPECIFICATIONS is wired as an NFPA Style B(Class B)Initiating Device Circuit. Nominal operating voltage: 15 to 32 VDC. A 47K ohm End-of-Line Resistor(provided)terminates the cir- cuit. Maximum current draw:5.1 mA(LED on). NMM-100P(A)OPERATION Maximum IDC wiring resistance:25 ohms. Each NMM-100P(A) uses one of the available module Average operating current: 300 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. the control panel and reports its type and the status(open/nor- EOL resistance:3.9K ohms. mal/short)of its Initiating Device Circuit(IDC). External supply voltage (between Terminals T3 and T4): NMM-100P(A) SPECIFICATIONS DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum.Current:90 mA per module maximum. Nominal operating voltage: 15 to 32 VDC. Temperature range:32°F to 120°F(0°C to 49°C). Average operating current: 350 pA, 1 communication every Humidity range: 10%to 9390 noncondensing. 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC wiring resistance:40 ohms. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:400 pA. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6999:C•10/06/2010 NDM-100(A) Dual Monitor Module • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); The NDM-100(A) Dual Monitor Module is intended for use in 227-03-E Vol.3(NDM-100) intelligent, two-wire systems. It provides two independent two- wire initiating device circuits(IDCs)at two separate,consecutive Product Line Information addresses.It is capable of monitoring normally open contact fire NOTE:A^suffix indicates ULC-listed model. alarm and supervisory devices.The module has a single panel- controlled LED. NMM-100(A):Monitor module. NOTE: The NDM-100(A)provides two Style B(Class B)!DC cir- NMM-100P(A):Monitor module,miniature. cults ONLY. Style D(Class A)IDC circuits are NOT supported in NZM-100(A):Monitor module,two-wire detectors. any application. NDM-100(A): Monitor module, dual,two independent Class B NDM-100(A)SPECIFICATIONS circuits. Normal operating voltage range: 15 to 32 VDC. SMB500:Optional surface-mount backbox. Maximum current draw:6.4 mA(LED on). NOTE: See installation instructions and refer to the SLC Wiring Average operating current: 750 pA(LED flashing). Manual,PN 52304. Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K ohms. Maximum SLC Wiring resistance:40 Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125"(5.398 cm)deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE:"Ones"addresses on the NDM-100(A)are 0,2, 4, 6, or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4"(10.16 cm)square,2.125"(5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635 • ULC:S635 • FM Approved • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100);7300-0028:0237(NDM-100) DN-6999:C•10/06/2010—Page 3 of 4 Notifier®and FireWarden®are registered trademarks and FireWatch°4 is a trademark of Honeywell International Inc. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. IS O w l`710 O This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. O E AT F E O We cannot cover all specific applications or anticipate all requirements. ENGINEERING R MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6999:C•10/06/2010 dn-60383:A2 NC-100R(A) N OT 1 F 1 E R® Relay Module for FireWarden Series Panels by Honeywell Addressable General The NC-100R(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices,such as fans,dampers,door hold- e ers,control equipment, etc.Addressability allows the dry con- tact to be activated, either manually or through panel programming,on a select basis. IN nrwn Features • '"°°°"" .i.4,"4Fa ACPtJ a. • Built-in type identification automatically identifies these devices to the control panel. `�s • Internal circuitry and relay powered directly by two-wire SLC loop. " • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when • activated. , • High noise immunity(EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. NC-10OR(A) • Direct Decade entry of address: 01 —99 with the FireWar- den-100-2(C)and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A) may be programmed to operate dry contacts Specifications for door holders,Air Handling Unit shutdown,etc.,and to reset Normal operating voltage: 15 to 32 VDC. four-wire smoke detector power. Maximum SLC current draw: 6.5 mA(LED). Construction Average operating current: 230 pA direct poll (CLIP mode), • The face plate is made of off-white heat-resistant plastic. 255 pA group poll with LED flashing. • Controls include two rotary switches for direct-dial entry of EOL resistance: not used. address setting. Temperature range: 32°F to 120°F(0°C to 49°C). • The NC-100R(A) provides two Form-C dry contacts that Humidity range: 10%to 93%non-condensing. switch together. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Operation 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 mm)deep box. Each NC-100R(A)uses one of the addresses on a SLC loop.It responds to regular polls from the control panel and reports its Relay Contact Ratings type and status. The LED blinks with each poll received. On command,it activates its internal relay. Maximum Current Load Description Application Rating Voltage Rotary switches set a unique address for each module. The 9 g address may be set before or after mounting. The built-in Resistive Non-Coded 30 VDC 3.0 A TYPE CODE(not settable)will identify the module to the con- trol panel. Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive(LJR=5ms) Coded 30 VDC 0.5 A Inductive(L/R=2ms) Coded 30 VDC 1.0 A Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2•06/17/10—Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL/ULC Listed:S635. • CSFM approved:file 7300-0028:230. • FM approved. • MEA approved:file 72-01-E, Vol.2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA:Intelligent addressable relay module,ULC listed model. SMB500:Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual,document 52304. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I wV`O 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. c E R T•F/E We cannot cover all specific applications or anticipate all requirements. ENGINEERING 6 MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-60383:A2.06/17/10 DN-7001:D•A1-380 NOT-BG 12LX ® N OT I F I E R° Addressable Manual Pull Station by Honeywell intelligent/Addressable Devices General The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station FIRE that includes an addressable interface for FireWarden series intelligent control panels,and the NSP-25 panel. Because the NOT-BG12LX is addressable,the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. PUSH IN Features *PULL DOWN*.. • Maintenance personnel can open station for inspection and I address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station,flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. 'L • Captive screw terminals wire-ready for easy connection to VNOT1t=tER SLC loop(accepts up to 12 AWG/3.25 mm2 wire). 4 S • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- , gang,double-gang,or 4"(10.16 cm)square electrical box. • Smooth dual-action design. The NOT-BG1 2LX • Meets ADAAG controls and operating mechanisms guide- Addressable Manual Pull Station lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. The BG12TR is usually needed for semi-flush mounting with 4" • Attractive shape and textured finish. (10.16 cm)or double-gang boxes(not with single-gang boxes). • Key reset. • Includes Braille text on station handle. Operation • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch Meets UL 38, Standard for Manually Actuated Signaling in the down/activated position.Once latched,the word"ACTT- • Boxes. VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station.To reset the station,simply unlock the station with the Construction key and pull the door open.This action resets the handle;dos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —99 on NFW2-100/NFW2-100C, 1 —50 for NFW-50/NFW- • Shipping Weight:9.6 oz.(272.15 g) 50C). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 pA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot • For use indoors in a dry location be restored to normal except by use of a key.An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The NOT-BG12LX will mount semi-flush into a single-gang, mg instructions provided on the cover. The word FIRE shall double-gang,or standard 4"(10.16 cm)square electrical outlet appear on the front of the stations in white letters, 1.00 inches box, or will surface mount to the model SB-10 or SB-I/O sur- (2.54 cm) or larger. Stations shall be suitable for surface face backbox. If the NOT-BG12LX is being semi-flush mounting on matching backbox SB-10 or SB-I/O;or semi-flush mounted, then the optional trim ring (BG12TR) may be used. mounting on a standard single-gang, double-gang, or 4'(10.16 cm) square electrical box, and shall be installed DN-7001:D•4/13/2012—Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10:Surface backbox;metal. SB-UO:Surface backbox;plastic. BG12TR:Optional trim ring. 17021:Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • ULJULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E Vol. IV. • CSFM:7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9oo This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERTIFIED We cannot cover all specific applications or anticipate all requirements. FAtINEERINt&MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Mmemee adeint For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-7001:D•4/13/2012 DN-60979:A NP-200 Series Addressable Photoelectric NOTIFIER® Detectors by Honeywell Addressable Devices General The NOTIFIER NP-200 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek,contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. Exclusively for use with NOTIFIER's FireWarden Series Addressable • Fire Alarm Control Panels, the NP-200 Series point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for emergency personnel quickly locate a fire during its early stages, potentially t"^ saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local,visible sensor indi- cation. Dual electronic thermistors add 135°F(57°C)fixed tempera- ture thermal sensing on the NP-200T.The NP-200R is a remote test capable detector for use with DNR Series duct detector housings. Features NP-200 in B300-6 Base SLC LOOP • Two-wire loop connection. Mount base (all base types) on an electrical backbox which is at • Unit uses base for wiring, least 1.5"(3.81 cm)deep. For a chart of compatible junction boxes, see DN-60054. ADDRESSING NOTE:Because of the inherent supervision provided by the SLC loop, • Addressable by device, end-of-line resistors are not required. Wiring 7-taps"or branches are • Rotary,decimal addressing:Please refer to the FireWarden panel permitted for Style 4(Class B)wiring.NP-200R mounts in a DNR/ONRW manuals for device capacity. duct detector housing. ARCHITECTURE Operation • New modern profile for improved aesthetics. Each NP-200 Series detector uses one possible addresses on the • Unique single-source design to respond quickly and dependably FireWarden Signaling Line Circuit(SLC).It responds to regular polls to a broad range of fires, from the system and reports its type and status. • Integral communications and built-in type identification. • Built-in tamper-resistant feature. Detector Sensitivity Test • Removable cover and insect-resistant screen for simple field Each detector can have its sensitivity tested(required per NFPA 72, cleaning. Chapter 14 on Inspection, Testing and Maintenance)when installed/ OPERATION connected to an FireWarden Series addressable fire alarm control panel. The results of the sensitivity test can be printed off the Fire- • Designed to meet UL 268 7th Edition. Warden Series for record keeping. • Factory preset at 1.5%nominal sensitivity for panel alarm thresh- old level. Specification • Visible LED'blinks"when the unit is addressed (communicating Voltage range: 15—32 VDC(peak). with the fire panel)and latches on in alarm. • Low standby current. Standby current:200 pA @ 24 VDC. MECHANICALS Max current:4.5 mA @ 24 VDC(latched"ON"). • Sealed against back pressure. Air velocity:4,000 ft./min.(20 m/sec.)maximum. • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) Sensitivity:UL Applications:0.5%to 4.0%per foot obscuration octagonal box, or 4.0" (10.16 cm) square electrical box (with or Size:2.0"(5.3 cm)high;base determines diameter. without a mud ring-not included). —B300-6:6.1"(15.6 cm)diameter. OPTIONS —B501:4'(10.2 cm)diameter. • Remote LED output connection,RA100Z. For a complete list of detector bases see DN-60981. Shipping weight:3.4 oz.(95 g). Installation Operating temperature range: NP-200 series plug-in detectors use a detachable mounting base to • NP-200:0°C to 50°C(32°F to 122°F); simplify installation,service and maintenance. • NP-200T:0°C to 38°C(32°F to 100°F). • NP-200R: installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). DN-60979:A•3/29/18—Page 1 of 3 Relative humidity: 10%-93%,non-condensing. B200S-WH:White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, Listings ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol.(CSFM:7300-1653:0213 Pending) Listings and approvals below apply to the NP200 Series detectors. In some cases, certain detectors may not be listed by certain B200S-IV: Ivory, Intelligent addressable sounder base capable of approval agencies, or listing may be in process. Consult factory for producing sound output in high or low volume with ANSI Temporal 3, latest listing status. ANSI Temporal 4,continuous tone,marching lone,and custom tone. Uses FlashScan protocol.. (CSFM:7300-1653:0213 Pending) • UUULC Listed:S911 • CSFM:7272-0028:0503 B200SA-WH:Same as B200S-WH, ULC listing. • FM Approved B200SA-IV:Same as B200S-IV,ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in Product Line Information English/French (required in Canada tor ULC applications with SO Series detector applications. NOTE:below. Detectors must be mounted to one of the Intelligent Bases listed B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO NOTE:IV"suffix indicates FlashScan®and CLIP device. Series detector applications,ULC listing. NP-200: White, Addressable photoelectric detector; B300-6 base B200S-LF-WH: White, Low Frequency Intelligent, programmable included.FlashScan only. sounder base. Produces a fundamental frequency of 520 Hz +/- NP-200-IV: Ivory, Addressable photoelectric detector; B300-6 base 10% with a square wave or its equivalent; designed to meet the included. NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 NP-200T:White,Same as NP-200 but with thermal element;B300-6 Pending) base included. FlashScan only. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable NP-200T-IV: Ivory, Same as NP-200 but with thermal element; sounder base. Produces a fundamental frequency of 520 Hz +/- B300 6 base included. 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238 NP-200R: White, Remote test capable addressable photoelectric Pending) detector for use with DNR(A)/DNRW.FlashScan only. B200SR-WH:White, Intelligent sounder base capable of producing NP-200R-IV: Ivory, Remote lest capable addressable photoelectric sound output with ANSI Temporal 3 or continuous tone.Intended for detector;for use with DNR(A)/DNRW. retrofit applications. (CSFM:7300-1653:0213 Pending) INTELLIGENT BASES B200SR-IV: Ivory, Intelligent sounder base capable of producing NOTE:For details on intelligent bases,see ON-60981. sound output with ANSI Temporal 3 or continuous tone.Intended for retrofit applications. (CSFM:7300-1653:0213 Pending) B300-6:White,6"base,standard flanged low-profile mounting base. B200SRA-WH: Same as B200SR-WH with,ULC listing. (CSFM:7300-1653:0109 Pending) B300-6-IS: White,6"base isolator. (CSFM: 7300-1653:0109 Pend- B200SRA-IV:Same as B200SR-IV in Ivory color, ULC listing. ing) B200SR-LF-WH: White, Low Frequency Intelligent, programmable B300-6-IV: Ivory,6" base, standard flanged low-profile mounting sounder base. Produces a fundamental frequency of 520 Hz +/- base. (CSFM:7300-1653:0109 Pending) 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- B300A-6:Same as B300-6,ULC listed. tions.(CSFM:7300-1653:0238 Pending) B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable ULC listed. sounder base. Produces a fundamental frequency of 520 Hz +/- B300-6-BP:Bulk pack of B300-6,package contains 10 10% with a square wave or its equivalent; designed to meet the 6501-WHITE: White, 4" standard European flangeless mounting NFPA 72 sleeping space requirement. Intended for retrofit applica- base.UUULC listed. (CSFM:7300-1653:0109 Pending) tions.(CSFM:7300-1653:0238 Pending) B501-BL: Black, 4" standard European flangeless mounting base. MOUNTING KITS AND ACCESSORIES UUULC listed. (CSFM:7300-1653:0109 Pending) TR300:White, replacement flange for B210LP(A)base. B501-IV: Ivory color, 4" standard European flangeless mounting TR300-IV: Ivory,replacement flange for B210LP(A)base. base. UUULC listed. (CSFM:7300-1653:0109 Pending) RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a B501 BP:Bulk pack of B501-WHITE contains 10. U.S. single-gang electrical box. For use with B501(A) and B300- B224RB-WH:White,relay base.(CSFM:7300-1653:0216 Pending) 6(A). B224RB-IV:Ivory,relay base.(CSFM:7300-1653:0216 Pending) M02-04 00:Test magnet. B224RBA-WH:White, relay base,ULC listing. M02-09-00:Test magnet with telescoping handle. B224RBA-IV: Ivory,relay base,ULC listing. B224BI-WH: White, isolator detector base. (CSFM: 7300- 1653:0216 Pending) B224B1-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216 Pending) B224BIA-WH:White, Isolator detector base,ULC listing. B224BIA-IV: Ivory Isolator detector base,ULC listing. ON-60979:A•3/29/18—Page 2 of 3 NOTIFIER® and FIREWARDEN® are a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. C E RT F E All specifications are subject to change without notice. ENGINEERING B MANUFACTURING QUALITY SYSTEMS For more information,contact Notifier.Phone:(800)627-3473,FAX:(203)484-7118. www.notifier.com Page 3 of 3—ON-60979:A•3/29/18 NOTIFIER� by Honeywell NH-200 Series Addressable Heat Detectors for FireWarden Series The NOTIFIER® NH-200 Series intelligent thermal detectors are designed for both performance and aesthetics, and are direct replacements for the NH-100 Series.A new modern,sleek,contem- porary design and advanced thermal technologies make the NH-200 Series ideal for both system operation and building design. The point ID address,set using rotary decimal switches,provide specific detector locations. Compatible with FireWarden®Series fire alarm control panels, the series includes a 135°F/57°C fixed-temperature, rate-of-rise, and a 190°F/88°C fixed high-temperature detectors.These thermal detec- tors provide effective, intelligent property protection in a variety of % applications. Detectors are available for both FlashScan®and CLIP applications as designated. Features 1 `� SLC LOOP: • Two-wire SLC loop connection • Unit uses base for wiring ADDRESSING: • Flanged surface mounting kit • Addressable by device • Rotary,decimal addressing Installation (Refer to the FireWarden panel manuals for device capacity.) NH-200 Series plug-in intelligent thermal detectors use a detachable ARCHITECTURE: base to simplify installation, service and maintenance. Installation • Designed to meet UL 268 7th Edition instructions are shipped with each detector. • Sleek,low-profile,stylish design Mount detector base(all base types)on an electrical backbox which • State-of-the-art thermistor technology for fast response is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes,see DN-60054. • Integral communications and built-in device-type identification • Built-in tamper resistant feature NOTE:Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 7-taps"or branches are • Built-in functional test switch activated by external magnet permitted for Style 4(Class"8)wiring only. OPERATION: When using relay or sounder bases, consult the N100-ISO installation sheet 156-3625 for device limitations between isolator modules and iso- • Fixed temperature model (NH-200) factory preset to 135°F lator bases. (57°C) • Rate-of-rise model(NH-200R),15°F(8.3°C)per minute Applications • High-temperature model (NH-200H) factory preset to 190°F Use thermal detectors for protection of property.For further informa- (88°C) tion, refer to 156-6522, Applications Manual for System Smoke • 360°-field viewing angle of the two visual alarm indicators, LEDs Detectors, which provides detailed information on detector spacing, blink red in Normal condition and turn on steady red in Alarm placement,zoning,wiring,and special applications. • LEDs blink every time the unit is polled MECHANICALS: Construction • Sealed against back pressure These detectors are constructed of fire-resistant plastic. The NH- 200 Series plug-in intelligent thermal detectors are designed to corn- • SEMS screws for wiring of the separate base mercial standards and offer an attractive appearance. • Designed for direct-surface or electrical-box mounting • Plugs into separate base for ease of installation and maintenance Operation • Separate base allows interchange of photoelectric,ionization and Each NH-200 Series detector uses one of the panel's addresses thermal sensors (total limit is panel dependent)on the FireWarden Signaling Line Cir- OTHER SYSTEM FEATURES: cuit (SLC). It responds to regular polls from the control panel and reports its type and the status.If it receives a test command from the • Remote test feature from the panel panel (or a local magnet test), it stimulates its electronics and • Walk test with address display reports an alarm. It blinks its LEDs when polled and turns the LEDs • Low standby current on when commanded by the panel. The NH-200 Series offers fea- tures and performance that represent the latest in thermal detector OPTIONS: technology. • Remote LED output connection to optional RA100Z remote LED annunciator DN-60980:B•6/26/2019—Page 1 of 3 Product Line Information B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable NOTE:=IV"suffix indicates CLIP and FlashScandevice. sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NH-200: White, low-profile intelligent 135°F fixed thermal sensor, NFPA 72 sleeping space requirement. Intended for retrofit applica- FlashScan only tions.(CSFM:7300-1653:0238) NH-200-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, MOUNTING KITS AND ACCESSORIES FlashScan and CLIP TR300:White,replacement flange for B210LP(A)base NH-200R: White, low-profile intelligent rate-of-rise thermal sensor, TR300-IV:Ivory,replacementflange ( ) FlashScan only for 8210LP A base NH-200R-IV: Ivory, low-profile intelligent rate-of-rise fixed thermal RA100Z:Remote LED annunciator.3-32 VDC.Mounts to a U.S.sin- sensor, FlashScan and CLIP gle-gang electrical box.For use with B501(A)and B300-6(A). NH-200H: White, low-profile intelligent 190°F fixed thermal sensor, M02-04-00:Test magnet FlashScan only M02-09-00:Test magnet with telescoping handle NH-200H-IV: Ivory, low-profile intelligent 190°F thermal sensor, CK300:Color Kit(includes cover and trim ring),white, 10-pack FlashScan and CLIP CK300-IV:Color Kit(includes cover and trim ring),ivory, 10-pack INTELLIGENT BASES CK300-BL:Color Kit(includes cover and trim ring), black, 10-pack NOTE:For details on intelligent bases,see DN-60981. B300-6:White,6"base,standard flanged low-profile mounting base (CSFM:7300-1653:0109) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base(CSFM:7300-1653:0109) B300-6-BP:Bulk pack of B300-6,package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UUULC listed(CSFM:7300-1653:0109) B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed(CSFM:7300-1653:0109) B501-IV: Ivory color, 4" standard European flangeless mounting base. UUULC listed (CSFM:7300-1653:0109) B501-WHITE-BP:Bulk pack of B501-WHITE contains 10 B224RB-WH:White,relay base(CSFM:7300-1653:0216) B224RB-IV: Ivory,relay base(CSFM:7300-1653:0216) B224BI-WH:White,isolator detector base(CSFM:7300-1653:0216) B224BI-IV: Ivory isolator detector base(CSFM:7300-1653:0216) B200S-WH:White,Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol. (CSFM:7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol.(CSFM:7300-1653:0213) B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM:7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement.(CSFM:7300-1653:0238) B200SR-WH:White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications.(CSFM:7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications.(CSFM: 7300-1653:0213) B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions.(CSFM:7300-1653:0238) Page 2 of 3—DN-60980:B•6/26/2019 SPECIFICATIONS Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC is 0.5%to 3.5% Size:2.0"(5.3 cm)high;base determines diameter —B300-6:6.1"(15.6 cm)diameter —B501:4"(10.2 cm)diameter For a complete list of detector bases see ON-60981 Shipping weight:3.4 oz.(95 g) Operating temperature range: • NH-200,NH-200R Series:—4°F to 100°F(-20°C to 38°C) • NH-200H Series:—4°F to 150°F(-20°C to 66°C) Detector spacing: UL approved for 50 ft. (15.24 m)center-to-cen- ter,FM approved for 25 x 25 ft.(7.62 x 7.62 m)spacing Relative humidity: 10%—93%non-condensing Thermal ratings:fixed-temperature set point 135°F(57°C),rate-of- rise detection 15°F(8.3°C)per minute,high temperature heat 190°F (88°C) Mounting:B300-6(A)flanged base,included See"Product Line Information: Intelligent Bases,"if using a dif- ferent base. ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak Standby current(max.avg.):200{EA @ 24 VDC(one communica- tion every 5 seconds with LED enabled) Max current:4.5 mA @ 24 VDC("ON") Listings and Approvals Listings and approvals below apply to the NH-200 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UUULC Listing:S747 • FM Approved • CSFM:7270-0028:0502 ISO 9001 itamonamoci MINED=6 MAOAM = QUALITY SYSTEMS This document is not intended to be used for installation purposes. We by to keep our product information up-to-date ard accurate. We cannot cover all specific applications or anticipate all requirements. NOTI FI E R al spedfications are subject to charge without notice. 12 Clintonville Road F' z�ardeiu.Fashcr and NOPHER are registered trademarks of Hanenvell Aternat anal Inc Northford,CT 06472 �2n 9ny ey<..I Han b< 111 OT 1 F 1 E R`' r•amallcna�Inc Al righ;e re5arvetl.UnauUorized 203.484.7161 x of this document is stncay orahibtlea www.notifier.com Country of Origin:Mexico by Honeywell DN-60918:B Indoor Selectable-Output Horns, Strobes, and Horn N OT I F I E R Strobes for Wall Applications by Honeywell Audio/Visual Devices General The L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry with lower cur- rent draws and modern aesthetics.With white and red plastic r f housings, standard and small footprint devices, and plain, FIRE-printed devices,L-Series can meet virtually any applica- R e R tion requirement. The L-Series product line of wall-mount horns, strobes, and h horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back P2RL box, making installations fast and foolproof while virtually elim- inating costly and time-consuming ground faults. To further simplify installation and protect devices from con- struction damage, L-Series utilizes a universal mounting plate for all standard and compact models with an onboard shorting spring,so installers can test wiring continuity before the device F is Installed. i Installers can also easily adapt devices to a suit a wide range 'i r•n° R of application requirements using field-selectable candela set- E ` P E tings, automatic selection of 12- or 24-volt operation, and a I rotary switch for horn tones with two volume selections. k Features P2GWL SGWL • Updated modern aesthetics. • Small profile devices for Horns and Horn Strobes. • Plug-in design with minimal intrusion into the back box. • Tamper-resistant construction. 1:11 • Automatic selection of 12-or 24-volt operation at 15 and 30 1::;::: candela. I i • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110,135,and 185. • Horn rated at 88+dBA at 16 volts. • Rotary switch for horn tone and two volume selections. • Universal mounting plate for all standard and all compact HWL wall units. • Mounting plate shorting spring checks wiring continuity. before device installation. • Electrically Compatible with legacy SpectrAlert® and 12 or 24 volts. When used with the Sync•Circuit Module, 12- SpectrAlert Advance devices. volt-rated notification appliance circuit outputs shall operate • Compatible with MDL3 sync module. between 8.5 and 17.5 volts; 24-volt-rated c appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor • Listed for wall mounting only. L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or lull-wave rectified unaltered Architectural/Engineering Specifications power supply.Strobes and horn strobes shall have field-select- General: L-Series standard horns, strobes, and horn strobes able candela settings including 15, 30, 75, 95, 110, 135, and shall mount to a standard 2- x 4" x 17/8" back box, 4" x 4' x 185. 1312"back box,4"octagon back box,or double-gang back box. Strobe. The strobe shall be a L-Series Model listed to UL L-Series compact products shall mount to a single-gang 2' x 1971 and shall be approved for fire protective service. The 4"x 17/8" back box. A universal mounting plate shall be used strobe shall be wired as a primary-signaling notification appli- for mounting ceiling and wall products for all standard-size ance and comply with the Americans with Disabilities Act models and a separate universal mounting plate shall be used requirements for visible signaling appliances, flashing at 1 Hz for mounting compact wall models.The notification appliance over the strobe's entire operating voltage range. The strobe circuit wiring shall terminate at the universal mounting plate. light shall consist of a xenon flash tube and associated lens/ Also, L-Series products, when used with the Sync.CircuitTM reflector system. Module accessory, shall be powered from a non-coded notifi- cation appliance circuit output and shall operate on a nominal DN-60918:B•6/19/17—Page 1 Of 4 Horn Strobe Combination. The horn strobe shall be a L-Series Drawings L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be Compact Horn wired as a primary-signaling notification appliance and comply with then Americans with Disabilities Act Hz o requirements the for visi- 3.46 1.25 ble signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The -_ _ ;L--- horn shall have two audibility options and an option to switch tiLi � /; between a temporal three pattern and a non-temporal(contin- .'13u';'u'u a uous) pattern. These options are set by a multiple position 000e000°�ea , switch. The horn on horn strobe models shall operate on a 5.27 p000p000pr°o• coded or non-coded power supply. , o0 8 11®a®oe Synchronization Module.The module shall be a Sync•Circuit pol°�o�ee°�o model MDL3 listed to UL 464 and shall be approved for fire ° °eke° °° protective service. The module shall synchronize SpectrAlert _ ° ,i strobes at 1 Hz and horns at temporal three.Also, while oper- ating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/8" x 471/18" x 21/8" back box. The module shall Compact Combo also control two Style Y(class 0)circuits or one Style Z(class - 1.91 A)circuit.The module shall synchronize multiple zones. Daisy 3.46 chaining two or more synchronization modules together will - - 1.2€ synchronize all the zones they control. The module shall not __ operate on a coded power supply. m , `\ 111/1 PHYSICAL/ELECTRICAL SPECIFICATIONS .000'40 • Standard Operating Temperature: 32°F 10 120°F(0°C to °0.°;,00,1. 49°C). 5.27 ■il l • Humidity Range: 10 to 93%non-condensing. II • Strobe Flash Rate: 1 flash per second. Millar `til,. • Nominal Voltage: Regulated 12 DC or regulated 24 DC/ `-• FWR1 (full wave rectified). N. o- _ Ill • Operating Voltage Range2: 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal). • Operating Voltage Range:MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal). Horn • Input Terminal Wire Gauge: 12 to 18 AWG. 4,70 -- Wall-Mount Dimensions(including lens):5.6"L x 4.7"W 1.25 • x 1.25"D(143 mm L x 119 mm W x 32 mm D). • Compact Wall-Mount Dimensions(Including lens):5.26" Lx3.46"Wx1.93"D(133mmLx88mmWx49mmD), tis • 're°„'Horn Dimensions:5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D). 5.67 .0 0Wr, CI • Compact Horn Dimensions: 5.25" L x 3.45"W x 1.25" D ;e•(;�i;1; . • (133mm L x 88mm W x 32mm D). .•..de45 - NOTE: ° -a.°_� 1.Full Wave Rectified(FWR)voltage is a non-regulated,time- varying power source that is used on some power supply and panel outputs. Combo 2.P,S,PC,and SC products will operate at 12 V nominal only - 4.70 for 15 cd and 30 cd. 1.91 1.25 r C-Z7) 5.67 "`" Page 2 of 4—DN-60918:B•5/19/17 UL Current Draw Data UL MAX.HORN CURRENT DRAW(MA RMS) UL MAX.STROBE CURRENT DRAW(MA RMS) The 3.1 k is the sound of the mini-horns. The EM (which stands for Electro-mechanical)is the sound of the SpectrAlert 8-17.5 Advance line which uses an algorithm that hops frequencies Volts 16-33 Volts between 2Hz and 4Hz. Candela DC DC FWR 8-17.5 15 88 43 60 Volts 16-33 Volts 30 143 63 83 Sound Pattern dB DC DC FWR 75 N/A 107 136 Temporal High 39 44 54 95 N/A 121 155 Temporal Low 28 32 54 110 N/A 148 179 Non-Temporal High 43 47 54 135 N/A 172 209 Non-Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL MAX. CURRENT DRAW(MA RMS),2-WIRE HORN STROBE,CANDELA RANGE(15-115 CD) The 3.1k is the sound of the mini-horns. The EM (which stands for Electro-mechanical)is the sound of the SpectrAlert Advance line which uses an algorithm that hops frequencies between 2Hz and 4Hz. DC Input: 8-17.5 DC Input: FWR Input: Volts 16-33 Volts 16 FWR 15 30 15 30 75 95 110 135 185 15 30 75 95 110 135 185 cd cd cd cd cd cd cd cd cd cd cd cd cd cd cd cd Temporal High 98 158 54 74 121 142 162 196 245 83 107 156 177 198 234 287 Temporal Low 93 154 44 65 111 133 157 184 235 68 91 145 165 185 223 271 Non-Temporal High 106 166 73 94 139 160 182 211 262 111 135 185 207 230 264 316 Non-TemporalLow 93 156 51 71 119 139 162 190 239 79 104 157 175 197 235 283 3.1K Temporal High 93 156 53 73 119 140 164 190 242 81 105 155 177 196 234 284 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 68 90 145 166 186 222 276 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 104 131 177 204 230 264 326 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 77 102 156 177 199 234 291 DN-60918:B•5/19/17—Page 3 of 4 HORN TONES AND SOUND OUTPUT DATA: HORN Product Line Information AND HORN STROBE OUTPUT(DBA) WALL HORN STROBES The 3.1k is the sound of the mini-horns. The EM (which P2WL(A)(-E)(-F), P2RL(AX-E)(-F). 2-Wire, Horn Strobe stands for Electro-mechanical) is the sound of the SpectrAlert (White,Red). Advance line which uses an algorithm that hops frequencies P2GWL(A)(-E)(-F), P2GRL(A)(-E)(-F).2-Wire, Compact Horn between 2Hz and 4Hz. Strobe(White,Red). In the coded positions, temporal coding must be provided by the NAC. If the NAC voltage is held constant,the horn output P2WL(A)-P, P2RL(A)-P. 2-Wire, Horn Strobe, Plain (White, will remain constantly on. Red). 8-17.5 P2WL-SP, P2RL-SP. 2-Wire, Horn Strobe, FUEGO (White, Volts 16-33 Volts Red). Pos. Sound Pattern dB DC DC FWR WALL STROBES 1 Temporal High 84 89 89 SWL(A)(-EX-F),SRL(A)(-EX-F).Strobe,Red(White, Red). 2 Temporal Low 75 83 83 SGWL(A)(-E)(-F), SGRL(A)(-E)(-F). Compact Strobe (White, Red). 3 Non-Temporal High 85 90 90 SWL(A)-P,SRL(A)-P.Strobe, Plain(White,Red). 4 Non-Temporal Low 76 84 84 SRL-SP.Strobe,FUEGO(Red). 5 3.1 KHz Temporal High 83 88 88 SWL-CLR-ALERT.Strobe,ALERT(White). 6 3.1 KHz Temporal Low 76 82 82 SWL-ALERT.Strobe,Wall,Amber Lens,ALERT(White). 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 HORNS 9t Coded High 85 90 90 HWL(A),HRL(A).Horn(White, Red). 10t 3.1 KHz Coded High 84 89 89 HGWL(A),HGRL(A).Compact Horn(White, Red). ACCESSORIES tSettings 9 and 10 are not available on the 2-wire horn strobes. TR-2W,TR-2.Universal Wall Trim Ring(White, Red). Agency Listings and Approvals SBBWL,SBBRL.Wall Surface Mount Back Box(White, Red). The listings and approvals below apply to L-series devices. In SBBGWL,SBBGRL.Compact Wall Surface Mount Back Box some cases,certain modules or applications may not be listed (White,Red). by certain approval agencies, or listing may be in process. NOTE: "A"suffix indicates ULC-Listed model. ULC-listed devices Consult factory for latest listing status. include required French labeling. See Agency Listings for listing • UL/ULC-Listed details. -S4011 Wall Horn Strobes NOTE: "A"suffix indicates ULC-listed models, ULC models have —S5512 Wall Strobes FIRE/FEU marking on cover. S5512 Wall Horns NOTE: ULC-listed models add"-E"suffix for English only"FIRE" marking on cover. -S5512 Strobe-only ALERT devices NOTE: ULC-listed models add "-F"suffix for French only "FEU" • FM Approved(All except ALERT models) marking on cover. • CSFM Listed: 7135-1653:0503(Wall Horns and Wall Horn Strobes),7125-1653:0504(Wall Strobes) NOTIFIER® and SpectrAlert® are registered trademarks and Sync•Circuit""is a trademark of Honeywell International Inc. 02017 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I w SO 900 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E Ft T 1 F E O We cannot cover all specific applications or anticipate all requirements. UIiIf llriaMAlIMc11Ilrl All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-60918:B•5/19/17 DN-60938:B Indoor Selectable-Output Strobes and Horn Strobes for NOT 1 F 1 E R'�' Ceiling Applications by Honeywell Audio/Visual Devices General System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthet- ics. ='• y r The System Sensor L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the .11 industry with lower current draws and modern aesthetics.With • asp white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any appli- cation requirement. The entire L-Series product line of ceiling-mount strobes and SCRL PC2WL horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices Architect/Engineer Specifications feature a plug-in design with minimal intrusion into the back box,making installations fast and foolproof while virtually elim- GENERAL hating costly and time-consuming ground faults. L-Series ceiling-mount strobes and horn strobes shall mount To further simplify installation,the L-Series utilizes a universal to a standard 4 x 4 x 1 1-inch back box, 4-inch octagon back mounting plate so installers can mount them to a wide array of box, or double-gang back box. Two-wire products shall also back boxes. With an onboard shorting spring, installers can mount to a single-gang 2 x 4 x 17/8 inch back box. A universal test wiring continuity before the device is installed. mounting plate shall be used for mounting ceiling and wall Installers can also easily adapt devices to a suit a wide range products. The notification appliance circuit wiring shall termi- of application requirements using field-selectable candela set- nate at the universal mounting plate. Also, L-Series products, tings, automatic selection of 12- or 24-volt operation, and a when used with the Sync•Circuit`"Module accessory,shall be rotary switch for horn tones with two volume selections. powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with Features the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24- • Plug-in design with minimal intrusion into the back box volt-rated notification appliance circuit outputs shall operate • Tamper-resistant construction between 16.5 and 33 volts. Indoor L-Series products shall • Automatic selection of 12-or 24-volt operation operate between 32 and 120 degrees Fahrenheit from a regu- at 15 and 30 candela lated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela • Field-selectable candela settings on ceiling units: settings including 15,30,75,95, 115, 150,and 177. 15,30,75,95, 115, 150,and 177 • Horn rated at 88+dBA at 16 volts STROBE • Rotary switch for horn tone and two volume selections The strobe shall be a System Sensor L-Series Model • Universal mounting plate for ceiling units listed to UL 1971 and shall be approved for fire protective ser- vice.The strobe shall be wired as a primary-signaling notifica- • Mounting plate shorting spring feature checks wiring conti- Lion appliance and comply with the Americans with Disabilities nuity before device installation Act requirements for visible signaling appliances,flashing at 1 • Electrically compatible with legacy SpectrAlert and Hz over the strobe's entire operating voltage range.The strobe SpectrAlert Advance devices light shall consist of a xenon flash tube and associated lens/ • Compatible with MDL3 sync module reflector system. • Listed for ceiling mounting only HORN STROBE COMBINATION The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signal- ing appliances,flashing at 1 Hz over the strobe's entire operat- ing voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pat- tern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non- coded power supply. DN-60938:B•5/15/17—Page 1 of 4 SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4'1/18 x 411/18 x 21/8 inch back box.The module shall also con- trol two Style Y(class B) circuits or one Style Z(class A)cir- cuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL/ELECTRICAL SPECIFICATIONS • Standard Operating Temperature: 32°F to 120°F(0°C to 49°C) • Humidity Range: 10 to 93%non-condensing • Strobe Flash Rate: 1 flash per second • Nominal Voltage: Regulated 12VDC or regulated 24DC/ FWR1 • Operating Voltage Range2: 8 to 17.5V (12V nominal) or 16 to 33V(24V nominal) • Operating Voltage Range with MLD3: 8.5 to 17.5V(12V nominal)or 16.5 to 33V(24V nominal) • Input terminal wire gauge: 12 to 18 AWG • Ceiling-Mount Dimensions(including lens): 6.8" diame- ter 2.5•high(173 mm diameter 64 mm high) • Ceiling-Mount Surface Mount Back Box Skirt Dimen- sions (SBBCR, SBBCW): 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) Notes: 1. Full Wave Rectified(FWR)voltage is a non-filtered,time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. UL Current Draw Data UL MAX.STROBE CURRENT DRAW(MA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 I 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 *This data represents coding at 3 chimes per second. Actual current draw will vary depending upon coding selected. Page 2 of 4—DN-60938:6.5/15/17 UL MAX.CHIME/STROBE CURRENT DRAW(MA RMS),2-WIRE HORN STROBE The 3.1k is the sound of the mini-horns. The EM(which stands for Electro-mechanical)is the sound of the SpectrAlert Advance line which uses an algorithm that hops frequencies between 2Hz and 4Hz. 8 VDC 16 VDC Candela 15 30 15 30 75 95 115 150 177 Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temporal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16VFWR Candela 15 30 75 95 115 150 177 Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temporal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1KTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data HORN AND HORN STROBE OUTPUT(OBA) 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 1 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 DN-60936:B•5/15/17—Page 3 of 4 DN-7087:C1 SpectrAlert® Advance N ®T I F I E R® Selectable Output Notification Appliances by Honeywell Audio/Visual Devices General System Sensor® SpectrAlert® Advance selectable-output horns,strobes and horn/strobes are rich with features guaran- teed to cut installation times and maximize profits. The Spec- trAlert Advance series of notification appliances is designed to ?_ simplify your installations, with features such as: plug-in designs,instant feedback messages to ensure correct installa- Indoor Ceiling Outdoor Ceiling tion of individual devices, and eleven field-selectable candela Horn/Strobe Strobe settings for wall and ceiling strobes and horn/strobes. More specifically when installingAdvance Products, first attach a universal mounting plate to a four-inch square, four- inch octagon, or double-gang junction box. The two-wire .11 mounting plate attaches to a single-gang junction box. Then, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Indoor Wall Indoor Ceiling Finally,attach the horn,strobe,or horn/strobe to the mounting Horn/Strobe Strobe plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the prod- uct's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a a captured mounting screw. SpectrAlert Advance products allow you to choose: P. • 12 or 24 volts. Indoor Wall Outdoor Wall • 15, 15/75,30,75,95, 110, 115, 135, 150, 177,or 185 can- Horn Strobe dela by way of a rear-mounted slide switch and front view- • Outdoor products rated from—40°F and 151°F (-40°C and ing window. 66°C). • Horn tones and volume by way of a rotary switch. • Outdoor products rainproof per UL50 (NEMA 3R) and • The SpectrAlert Advance series includes outdoor notifica- weatherproof per NEMA 4X, IP56 tion appliances. Outdoor strobes and horn/strobes (two- • Minimal intrusion into the backbox. wire and four-wire) are available for wall or ceiling.Outdoor • Horn rated at 88+dbA at 16 volts. horns are available for wall only.All System Sensor outdoor • Rotary switch for tone selection. products are rated between—40°F and 151°F (-40°C and • Three horn volume settings. 66°C)in wet or dry applications. Models available: • Electrically compatible with existing SpectrAlert products. • Indoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire Engineering Specifications horn/strobe. • Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire SpectrAlert Advance horns, strobes, and horn/strobes shall horn/strobe. mount to a standard 4.0" x 4.0" x 1.5" (10.16 x 10.16 x 3.81 • Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4- cm)backbox,4.0"(10.16 cm)octagonal backbox,or a double- wire horn/strobe. gang backbox.Two-wire products shall also mount to a single- gang 2.0"x 4.0"x 1.875"(5.08 x 10.16 x 4.763 cm)backbox.A • Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire universal mounting plate shall be used for mounting ceiling horn/strobe. and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, Spec- Features trAlert Advance products, when used with the Sync•CircuitT"" Plug-in design. Module accessory, shall be powered from a non-coded notifi- • cation appliance circuit output and shall operate on a nominal • Same mounting plate for wall-and ceiling-mount units. 12 or 24 volts. When used with the Sync•Circuit Module, 12- • Shorting spring on mounting plate for continuity check volt rated notification appliance circuit outputs shall operate before installation. between 9 and 17.5 volts; 24-volt rated notification appliance • Captive mounting screw. circuit outputs shall operate between 17 and 33 volts. Indoor • Tamper-resistance capability. SpectrAlert Advance products shall operate between 32°F and 120°F(0°C and 49°C)from a regulated DC,or full-wave-recti- • Field-selectable candela settings on wall and ceiling units: fied, unfiltered power supply. Strobes and horn/strobes shall 15, 15/75,30,75,95, 110, 115,135, 150, 177, 185. have field-selectable candela settings including 15, 15/75, 30, • Automatic selection of 12 or 24 volt operation at 15 and 15/ 75,95,110, 115, 135, 150, 177, 185. 75 candela. • Outdoor wall and ceiling products. DN-7087:C1•11/9/11—Page 1 of 4 STROBE Operating Specifications The strobe shall be a System Sensor SpectrAlert Advance • Standard operating temperature: 32°F to 120°F (0°C to Model listed to UL 1971 and shall be approved for fire 49°C) protective service.The strobe shall be wired as a primary-sig- naling notification appliance and comply with the Americans • K Series operating temperature: 40°F to 151°F (-40°C with Disabilities Act requirements for visible signaling appli- to 66°C). ances,flashing at 1 Hz over the strobe's entire operating volt- • Humidity range: 10% to 93% non-condensing (indoor age range.The strobe light shall consist of a xenon flash tube products). and associated lens/reflector system. • Strobe flash rate: 1 flash per second. HORN/STROBE COMBINATION • Nominal voltage: regulated 12 VDC/FWR or regulated 24 The horn/strobe shall be a System Sensor SpectrAlert VDC/FWR. NOTE:Full Wave Rectified(FWR) voltage is a Advance Model listed to UL 1971 and UL 464 and non-regulated, time-varying power source that is used on shall be approved for fire protective service. The horn/strobe some power supply and panel outputs. shall be wired as a primary-signaling notification appliance • Operating voltage range:8 V to 17.5 V(12 V nominal);or and comply with the Americans with Disabilities Act require- 16 V to 33 V(24 V nominal).NOTE:P,S,PC,and SC prod- ments for visible signaling appliances,flashing at 1 Hz over the ucts will operate at 12 V nominal only for 15 cd and 15/75 strobe's entire operating voltage range. The strobe light shall cd. consist of a xenon flash tube and associated lens/reflector sys- • Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 tern.The horn shall have three audibility options and an option mm2). to switch between a Temporal 3 pattern and a Non-Temporal • Ceiling-mount dimensions(including lens): 6.8"diame- (continuous)pattern.These options are set by a multiple posi- ter x 2.5"deep(17.3 cm diameter x 6.4 cm deep). tion switch.On four-wire products,the strobe shall be powered • Wall-mount dimensions(including lens):5.6"H x 4.7"W independently of the sounder.The horn on horn/strobe models x 2.5"D(14.2 cm H x 11.9 cm W x 6.4 cm D). shall operate on a coded or non-coded power supply. • Horn dimensions: 5.6" H x 4.7"W x 1.3" D (14.2 cm H x OUTDOOR PRODUCTS 11.9 cm W x 3.3 cm D). SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate Agency Listings and Approvals between —40°F and 151°F (-40°C and 66°C). The products The listings and approvals below apply to SpectrAlert Advance shall be listed for use with a System Sensor outdoor/weather- Selectable Output Notification Devices.In some cases,certain proof backbox with half-inch and three-fourths-inch conduit modules may not be listed by certain approval agencies, or entries. listing may be in process. Consult factory for latest listing sta- SYNCHRONIZATION MODULE tus. The module shall be a System Sensor Sync•Circuit MDL3R or • UL Listed: S4011 (HR_, HW_, P2_, P4_, PC2_, MDL3W listed to UL 464 and shall be approved for fire protec- PC4 models); S5512 (models SCR, SCRH, SCW, tive service.The module shall synchronize SpectrAlert strobes SCWH, SR, SRH, SW, SWH); S3593 (SCRHK, SCRK, at 1 Hz and horns at Temporal 3. Also, while operating the SRHK,SRK). strobes, the module shall silence the horns on horn/strobe • ULC Listed: S4011 (HRA, HRKA); S5512 (typically "A" models over a single pair of wires.The module shall mount to models, with exception of outdoor strobes). See Canadian a 4.688"x 4.688"x 2.125"(11.906 x 11.906 x 5.398 cm)back- data sheet for listings and specifications. box. The module shall also control two Style Y (class B) cir- . FM approved cuits or one Style Z (Class A) circuit. The module shall • MEA:452-05-E synchronize multiple zones. Daisy-chaining two or more syn- chronization modules together will synchronize all the zones • CSFM: 7125-1653:0186 (SCR, SCRH, SCW, SCWH, SR, they control.The module shall not operate on a coded power SRH,SW,SWH);7300-1653:0188(P2_, P4_, PC2_, PC4_ supply. modules); 7135-1653:0189 (HR, HRK, HW); 7300 1653:0187(SCRHK,SCRK, SRHK,SRK). Strobe Current Draw, Horn Current Draw, UL Maximum (mA RMS) UL Maximum (mA RMS) 8-17.5V 16-33V Sound 8-17.5V 16-33V Candela dB DC FWR DC FWR Pattern DC FWR DC FWR 15 123 128 66 71 Temporal High 57 55 69 75 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Standard 30 NA N/A 94 96 Temporal Low 38 44 44 48 Candela 75 NA NA 158 153 Non-temporal High 57 56 69 75 Range 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 135 NA NA 228 207 Coded Medium 44 51 56 69 High 150 NA NA 246 220 Coded Low 40 46 52 50 Candela Range 177 NA NA 281 251 185 NA NA 286 258 Page 2 of 4—DN-7087:C1•11/9/11 Horn and Horn/Strobe Horn and Horn/Strobe Output (dBA) Rotary Switch Setting 8—17.5 V 16—33 V Setting Repetition Rate dB Level Switch Sound dB Position Pattern FW FW DC 1 Temporal horn High R DC R 2 Temporal horn Medium 1 Temporal High 78 78 84 84 3 Temporal horn Low 2 Temporal Medium 74 74 80 80 4 Normal horn High 3 Temporal Low 71 73 76 76 5 Normal horn Medium 4 Non-temporal High 82 82 88 88 ' 6 Normal horn Low 5 Non-temporal Medium 78 78 85 85 7* Externally coded High 6 Non-temporal Low 75 75 81 81 8* Externally coded Medium 7* Coded High 82 82 88 88 9* Externally coded Low 8* Coded Medium 78 78 85 85 *NOTE:Settings 7,8,and 9 are not available 9* Coded Low 75 75 81 81 on 2-wire horn/strobe. *NOTE:Settings 7, 8, and 9 are not available on 2-wire horn/strobe. Two-Wire Horn/Strobe, STANDARD Candela Range (15 - 115 cd), UL Maximum Current Draw (mA RMS) Input, Sound Pattern,dB 8—17.5 V 16—33 V Level 15 15/75 15 15/75 30 75 95 110 115 DC Input,Temporal, High 137 147 79 90 107 176 194 212 218 DC Input,Temporal,Medium 132 144 69 80 97 157 182 201 210 DC Input,Temporal,Low 132 143 66 77 93 154 179 198 207 DC Input,Non-temporal,High 141 152 91 100 116 176 201 221 229 DC Input,Non-temporal,Medium 133 145 75 85 102 163 187 207 216 DC Input,Non-temporal,Low ' 131 144 68 79 96 156 182 201 210 FWR Input,Temporal,High 136 155 88 97 112 168 190 210 218 FWR Input,Temporal,Medium 129 152 78 '88 103 160 184 202 206 FWR Input,Temporal,Low 129 151 76 86 101 160 184 194 201 FWR Input,Non-temporal,High 142 161 103 112 126 181 203 221 229 FWR Input,Non-temporal,Medium 134 155 85 95 110 166 189 208 216 FWR Input,Non-temporal,Low 132 154 80 190 105 161 184 202 211 Two-Wire Horn/Strobe, H/GHCandela Range (135 - 185 cd), UL Maximum Current Draw (mA RMS) 16-33V 16-33V DC Input FWR Input 135 150 177 185 135 150 177 185 DC,Temporal,High 245 259 290 297 FWR,Temporal,High 215 231 258 265 DC,Temporal,Medium 235 253 288 297 FWR,Temporal,Medium 209 224 250 258 DC,Temporal,Low 232 251 282 292 FWR,Temporal,Low 207 221 248 256 DC,Non-temporal,High 255 270 303 309 FWR,Non-temporal,High 233 248 275 281 DC,Non-temporal,Medium 242 259 293 299 FWR,Non-temporal,Medium 219 232 262 267 DC,Non-temporal,Low 238 254 291 295 FWR,Non-temporal,Low 214 229 256 262 7O87Eim12 Q9.ti1 No it0 1„ 2.5 .,.,, ,,_ - ,...0 ) III 5.6" ', 10-2.5" DN-7087:C1•11/9/11—Page 3 of 4 Ordering Information Model Description Model Description WALL HORN/STROBES CEILING HORN/STROBES P2R 2-wire horn/strobe,standard cd,red. PC2R 2-wire horn/strobe,standard cd,red. P2RH 2-wire horn/strobe,high cd,red. PC2RH 2-wire horn/strobe,high cd,red. P2RK 2-wire horn/strobe,standard cd,red,outdoor. PC2RK 2-wire hom/strobe,standard cd,red,outdoor. P2RHK 2-wire horn/strobe,high cd,red,outdoor. PC2RHK 2-wire horn/strobe,high cd,red,outdoor. P2W 2-wire horn/strobe,standard cd,white. PC2W 2-wire hom/strobe,standard cd,white. P2WH 2-wire horn/strobe,high cd,white. PC2WH 2-wire hom/strobe,high cd,white. P4R 4-wire horn/strobe,standard cd,red. PC4R 4-wire hom/strobe,standard cd,red. P4RH 4-wire horn/strobe,high cd,red. PC4RH 4-wire horn/strobe,high cd,red. P4RK 4-wire horn/strobe,standard cd,red,outdoor. PC4RK 4-wire horn/strobe,standard cd,red,outdoor. P4RHK 4-wire hom/strobe,high cd,red,outdoor. PC4RHK 4-wire horn/strobe,high cd,red,outdoor. P4W 4-wire hom/strobe,standard cd,white. PC4W 4-wire horn/strobe,standard cd,white. P4WH 4-wire horn/strobe,high cd,white. PC4WH 4-wire horn/strobe,high cd,white. WALL STROBES CEILING STROBES SR Strobe,standard cd,red. SCR Strobe,standard cd,red. SRH Strobe,high cd,red. SCRH Strobe,high cd,red. SRK Strobe,standard cd,red,outdoor. SCRK Strobe,standard cd,red,outdoor. SRHK Strobe,high cd,red,outdoor. SCRHK Strobe,high cd,red,outdoor. SW Strobe,standard cd,white. SCW Strobe,standard cd,white. SWH Strobe,high cd,white. SCWH Strobe,high cd,white. ACCESSORIES HORNS BBS-2A Backbox skirt,wall,red. HR Horn,red. BBSW-2A Backbox skirt,wall,white. HRK Horn,red,outdoor. BBSC-2A Backbox skirt,ceiling,red. HW Horn,white. BBSCW-2A Backbox skirt,ceiling,white. ACCESSORIES,continued SA-WBB Weatherproof backbox,wall. TR-HS Trim Ring,wall,red,package of 5 SA-WBBC Weatherproof backbox,ceiling. TRW-HS Trim Ring,wall,white,package of 5 WTP Weatherproof,flush mount plate,red TRC-HS Trim Ring,ceiling,red,package of 5 WTPW Weatherproof,flush mount plate,white TRCW-HS Trim Ring,ceiling,white,package of 5 NOTE: "High cd"refers to strobes that include 135, 150, 177, and 185 candela settings. "Standard cd"refers to strobes that include 15, 15/75,30, 75,95, 110,and 115 candela settings. NOTE: For strobes and horn/strobes,add suffix"F'for French or"B"for Bilingual. NOTE: All outdoor models("K(A)"suffix)include a plastic weatherproof backbox. NOTE: Add"-R"to models for weatherproof replacement device (no back box included). Only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. NOTE: Add"P"to model for plain housing. (No"FIRE"marking on cover.) Sync•CircuiPl" is a trademark and NOTIFIER® and SpectrAlert® are registered trademarks of Honeywell International Inc. ©2011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I wV\O w 9oo This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. G E R T F E O We cannot cover all specific applications or anticipate all requirements. MINUS A MANUFACIOLINC All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-7087:C1•11/9/11 @b NOTI FI E R` by Honeywell L-Series Low Frequency Sounders and Sounder Strobes General L-Series audible visible notification products have features to maxi- mize profits with lower current draw and modern aesthetics. The L-Series offers the most versatile and easy-to-use line of low ;j;j.j,;;;. frequency sounder and low frequency sounder strobes in the indus- try. With white and red plastic housings, listed for wall and ceiling mounting, L-Series Low Frequency can meet virtually any applica- tion requirement. rr•. �' The low frequency sounder and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that r ,''p;'r%% r require a low frequency notification appliance that operates within ;„i,o,p frequency range of 520 Hz±10%and is of a square wave tone.Like i' ' 't•a the entire L-Series product line they include a variety of features that i Fi' increase their application versatility while simplifying installation.All a ,. a devices feature plug-in designs with minimal intrusion into the back ¢ E box,making installations fast and foolproof while virtually eliminating a ' costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, L-Series uses a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the HGRL-LFt:Compact low frequency sounder,wall, red device is installed. HGWL-LFt:Compact low frequency sounder,wall,white Installers can also easily adapt devices to a suit a wide range of HCRL-LFt:Low frequency sounder,ceiling,red application requirements using field-selectable candela settings,24- volt operation,and a rotary switch for 520 Hz low frequency sounder HCWL-LFt:Low frequency sounder,ceiling,white tones. tAdd-BP10 to order bulk pack of 10 units Low-frequency models include: ACCESSORIES • Wall-mount sounder strobes:P2RL-LF,P2WL-LF SBBRL:Surface mount back box,wall, red • Wall-mount sounders:HRL-LF,HWL-LF • Ceiling-mount sounders:HCRL-LF,HCWL-LF SBBWL: Surface mount back box,wall,white • Compact ceiling-mount sounders:HGRL-LF,HGWL-LF SBBCRL:Surface mount back box,ceiling,red SBBCWL:Surface mount back box,ceiling,white Features SBBGRL:Compact surface mount back box,wall, red • 520 Hz± 10%square wave tone,NFPA compliance SBBGWL: Compact surface mount back box,wall,white • Full candela range plus High/Low tone options to optimize current draw for a wide variety of applications Agency Listings and Approvals • Compact,standard,and round ceiling options These listings and approvals apply to the modules specified in • Field-selectable candela settings on wall units: 15, 30, 75, 95, this document. In some cases, certain modules or applications may 110,135,and 185 not be listed by certain approval agencies,or listing may be in pro- • Rotary switch for High and Low,Temp 3 and Temp4 settings cess.Consult the factory for the latest listing status. • Plug-in design with minimal intrusion into the back box • UL Listed:S4011 • Mounting plate shorting spring checks wiring continuity before • FM Approved:PR452768 device installation • CSFM: • Electrically compatible with legacy SpectrAlert and SpectrAlert Horns only:7135-1653:0516 Advance devices,and provides a direct replacement for HW/R-LF Horn/Strobes:7125-1653:0517 and P2R/WH-LF • Compatible with MDL3 sync module Architects/Engineers Specifications • Sounders listed for ceiling and wall mounting GENERAL • Sounder Strobe listed for wall mounting L-Series low frequency sounder and low frequency sounder strobes • Updated modern aesthetics shall mount to a standard 4 x 4 x 1.5-inch back box,4-inch octagon back box, or double-gang back box. Two-wire products shall also Product Line Information mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting products.The notification P2RL-LF: Low-frequency sounder strobe,wall, red appliance circuit wiring shall terminate at the universal mounting P2WL-LF:Low frequency sounder strobe,wall,white plate. Also, L-Series products, when used with the Sync•Circuit. t Module accessory, shall be powered from a non-coded notification HRL-LF : Low frequency sounder,wall,red appliance circuit output and shall operate on a nominal 12 or 24 HWL-LFt:Low frequency sounder,wall,white volts. When used with the Sync•Circuit Module, 24-volt-rated notifi- DN-62011:B•10/2/2019—Pagel of 3 cation appliance circuit outputs shall operate between 16.5 and 33 • Operating Voltage Range MDL3 Sync Module: 16.5 to 33 V volts. Indoor L-Series products shall operate between 32 and 120 (24 V nominal) degrees Fahrenheit(0°C to 49°C)from a regulated DC or full-wave • Input Terminal Wire Gauge: 12 to 18 AWG rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings including 15,30,75,95, DIMENSIONS 110, 135, 185. The field selectable tones will sound within the fre- • Wall Sounder Strobe Dimensions(including lens):5.6" L x quency range of 520 Hz±10%square wave tone and have a perma- 4.7"W x 1.9°D(142 mm L x 119 mm W x 49 mm D) nent marking on the housing that reads"low frequency sounder". • Standard Wall Sounder Dimensions:5.6" L x 4.7" W x 1.5" D LOW FREQUENCY SOUNDER (142 mm L x 119 mm W x 38 mm D) The low frequency sounder shall be a System Sensor L-Series • Compact Wall Sounder Dimensions:5.25" L x 3.46" W x 1.5" Model listed to UL 464 and shall be approved for fire pro- D(133mm L x 88mm W x 38mm D) tective service. The low frequency sounder and the Sync•Circuit. MDL3 Module accessory, if used, shall be powered from a notifica- • Ceiling Sounder Dimensions:6.8" diameter x 1.4" high tion appliance circuit output and shall operate on a nominal 24 volts (173mm diameter x 36mm high) (includes fire alarm panels with built in sync). When used with the • Standard Wall Sounder with SBBRUSBBWL Surface Mount Sync•Circuit Module MDL3, 24-volt rated notification appliance cir- Back Box:5.7"L x 4.8"W x 3.3" D(145 mm L x 120 mm W x 87 cult outputs shall operate between 16.5 to 33 volts.If the notification mm D) appliances are not UL 9th edition listed with the corresponding panel • Compact Wall Sounder with SBBGRUSBBGWL Surface or power supply being used,then refer to the compatibility listing of Mount Back Box:5.4"L x 3.6"W x 3.0"D(137 mmL x 91mm W the panel to determine maximum devices on a circuit. The low fre- x 76 mm D) quency sounder has an option to switch between temporal three or temporal four pattern,non-temporal(continuous) pattern and coded • Low Frequency Ceiling Sounder with SBBCRUSBBCWL Sur- supply within the frequency range of 520Hz ± 10% square wave face Mount Back Box:6.9"diameter x 3.9"high(175mm diame- tone. The low frequency sounder shall operate on a coded or non- ter x 99mm high) coded power supply with high and low volume settings. Notes:1.Full Wave Rectified(FWR)voltage is a non-regulated,time- LOW FREQUENCY SOUNDER STROBE COMBINATION varying power source that is used on some power supply and panel outputs. The low frequency sounder strobe shall be a System Sensor L- Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three or temporal four pattern and a non-temporal (continuous)pattern.These options are set by a multiple position switch.The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply with high and low volume settings.The field selectable tones will sound within the frequency range of 520 Hz*10%square wave tone. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Class B circuits or one Class A circuit. The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications • Standard Operating Temperature:32°F to 120°F(0°C to 49°C) • Humidity Range: 10 to 93%non-condensing • Frequency Range:520 Hz±10% • Strobe Flash Rate: 1 flash per second • Nominal Voltage Low Frequency Sounder:Regulated 24 DC/ FWR' • Nominal Voltage Range Low Frequency Sounder Strobe: Regulated 24 VDC/FWR1 • Operating Voltage Range: 16 to 33 V(24 V nominal) Page 2 of 3—DN-62011:B•10/2/2019 UL Current Draw and Sound Output Data Low Frequency Wall Sounder Strobe Current Draw(mA)and Sound Output(dBA) Sound Output Current Draw(mA) (dBA) Volume 16-33 VDC 16-33 FWR 16-33 V Pos Tone Setting 15cd 30cd!75cd 95cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd DC i FWR 1 Temporal3 High 98 115 158 173 182 212 266 136 153 188 206 228 258 304 80 80 2 Temporal3 Low 98 102 141 162 173 202 255 150 150 176 194 216 242 280 76 76 3 Temporal4 High 98 108 137 151 178 202 252 200 198 169 188 212 242 290 80 80 4 Temporal4 Low 102 104 122 136 163 187 237 176 174 154 173 197 227 275 76 76 5 Continuous High 141 158 198 216 234 264 305 190 207 249 268 289 321 368 80 80 6 Continuous Low 120 128 179 196 215 244 285 165 182 226 244 266 297 342 76 76 UL Max. Low Frequency Sounder Current Draw(mA RMS)', Sound Output Current Draw (dBA) (mA) Reverberant Volume 16-33 Volts 16-33 Volts Pos Tone Setting DC FWR DC FWR 1 Temporal 3 High 108 150 80 80 2 Temporal 3 Low 78 76 76 76 3 Temporal4 High 111 151 80 80 4 Temporal 4 Low 80 76 76 76 5 Continuous High 111 151 80 80 6 Continuous Low 80 76 76 76 7 Coded High 111 151 80 80 8 Coded Low 80 76 76 76 'NOTE:For coded tones,temporal coding must be provided by the NAC.If the NAC voltage is held constant,the sounder output will remain constantly on.Coded ratings provided are for continuous voltage. ISO 9001 ar IESIN6 I f YS T E E IUAIiIs SYSTEMS STEMS This document is not intended to be used for installation purposes. We try to keep cur product information up-to-date and accurate. We cannot cover as specific applications or anticipate all requirements, All specifications are subject to charge without notice. NOTIFIER r eehsar�x,NOTIFew.o.system Sensor!,and System Senacare my ste ed trademaMs of and Syno circuit'is a trace-nark d Naneywer 12 Clintonville Road irte national Inc. /� ii Northford,CT 06472 02010 be,asyw neI roterantional'nc Al nets reserved Lnauthodze° N QT I F I E R ,:se cl n duournent is sV Cry crahitlted 203.484.7161 www.notifier.com Country of Origin:Mexico by H o n eywe II NOTIFIER® by Honeywell L-Series Low Frequency Sounders and Sounder Strobes General L-Series audible visible notification products have features to maxi- mize profits with lower current draw and modern aesthetics. The L-Series offers the most versatile and easy-to-use line of low frequency sounder and low frequency sounder strobes in the Indus- try. With white and red plastic housings, listed for wall and ceiling mounting, L-Series Low Frequency can meet virtually any applica- tion requirement. • The low frequency sounder and low frequency sounder strobes were ;ismfel,rC } designed to address the NFPA 72 sleeping space requirements that ,,yr.;.,r,, f require a low frequency notification appliance that operates within frequency range of 520 Hz t 10%and is of a square wave tone.Like - the entire L-Series product line they include a variety of features that v" increase their application versatility while simplifying installation.All e a devices feature plug-in designs with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, L-Series uses a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the HGRL-LFt:Compact low frequency sounder,wall,red device is installed. HGWL-LFt:Compact low frequency sounder,wall,white Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings,24- HCRL-LFt:Low frequency sounder,ceiling,red volt operation,and a rotary switch for 520 Hz low frequency sounder HCWL-LFt: Low frequency sounder,ceiling,white tones. tAdd-BP10 to order bulk pack of 10 units Low-frequency models include: • Wall-mount sounder strobes:P2RL-LF, P2WL-LF ACCESSORIES • Wall-mount sounders:HRL-LF,HWL-LF SBBRL: Surface mount back box,wall,red • Ceiling-mount sounders:HCRL-LF,HCWL-LF SBBWL:Surface mount back box,wall,white • Compact ceiling-mount sounders:HGRL-LF,HGWL-LF SBBCRL:Surface mount back box,ceiling,red SBBCWL:Surface mount back box,ceiling,white Features SBBGRL:Compact surface mount back box,wall,red • 520 Hz±10%square wave tone, NFPA compliance SBBGWL:Compact surface mount back box,wall,white • Full candela range plus High/Low tone options to optimize current draw for a wide variety of applications Agency Listings and Approvals • Compact,standard,and round ceiling options These listings and approvals apply to the modules specified in • Field-selectable candela settings on wall units: 15, 30, 75, 95, this document. In some cases,certain modules or applications may 110, 135,and 185 not be listed by certain approval agencies,or listing may be in pro- • Rotary switch for High and Low,Temp 3 and Temp4 settings cess.Consult the factory for the latest listing status. • Plug-in design with minimal intrusion into the back box • UL Listed:S4011 • Mounting plate shorting spring checks wiring continuity before • FM Approved:PR452768 device installation • CSFM: • Electrically compatible with legacy SpectrAlert and SpectrAlert Horns only:7135-1653:0516 Advance devices,and provides a direct replacement for HW/R-LF Horn/Strobes:7125-1653:0517 and P2R/WH-LF • Compatible with MDL3 sync module Architects/Engineers Specifications • Sounders listed for ceiling and wall mounting GENERAL • Sounder Strobe listed for wall mounting L-Series low frequency sounder and low frequency sounder strobes • Updated modern aesthetics shall mount to a standard 4 x 4 x 1.5-inch back box,4-inch octagon back box, or double-gang back box. Two-wire products shall also Product Line Information mount to a single-gang 2 x 4 x 1 '/8-inch back box. A universal mounting plate shall be used for mounting products.The notification P2RL-LF:Low-frequency sounder strobe,wall,red appliance circuit wiring shall terminate at the universal mounting P2WL-LF:Low frequency sounder strobe,wall,white plate. Also, L-Series products, when used with the Sync•Circuit. Module accessory, shall be powered from a non-coded notification HRL-LFt: Low frequency sounder,wall,red appliance circuit output and shall operate on a nominal 12 or 24 HWL-LFt:Low frequency sounder,wall,white volts. When used with the Sync•Circuit Module,24-volt-rated notifi- ON-62011:B•10/2/2019—Page 1 of cation appliance circuit outputs shall operate between 16.5 and 33 • Operating Voltage Range MDL3 Sync Module: 16.5 to 33 V volts. Indoor L-Series products shall operate between 32 and 120 (24 V nominal) degrees Fahrenheit(0°C to 49°C)from a regulated DC or full-wave • Input Terminal Wire Gauge:12 to 18 AWG rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings including 15,30,75,95, DIMENSIONS 110, 135, 185. The field selectable tones will sound within the fre •- quency range of 520 Hz*10%square wave tone and have a perms- Wall Sounder Strobe Dimensions(including lens):5.6" L x nent marking on the housing that reads"low frequency sounder". 4.7"W x 1.9"D(142 mm L x 119 mm W x 49 mm D) • Standard Wall Sounder Dimensions:5.6" L x 4.7" W x 1.5" D LOW FREQUENCY SOUNDER (142 mm L x 119 mm W x 38 mm D) The low frequency sounder shall be a System Sensor L-Series . Compact Wall Sounder Dimensions:5.25" L x 3.46" W x 1.5" Model listed to UL 464 and shall be approved for fire pro- D(133mm L x 88mm W x 38mm D) tective service. The low frequency sounder and the Sync•Circuit. MDL3 Module accessory, if used, shall be powered from a notifica- • Ceiling Sounder Dimensions:6.8" diameter x 1.4" high tion appliance circuit output and shall operate on a nominal 24 volts (173mm diameter x 36mm high) (includes fire alarm panels with built in sync). When used with the • Standard Wall Sounder with SBBRUSBBWL Surface Mount Sync•Circuit Module MDL3, 24-volt rated notification appliance cir- Back Box:5.7"L x 4.8"W x 3.3" D(145 mm L x 120 mm W x 87 cull outputs shall operate between 16.5 to 33 volts.If the notification mm D) appliances are not UL 9th edition listed with the corresponding panel • Compact Wall Sounder with SBBGRUSBBGWL Surface or power supply being used,then refer to the compatibility listing of Mount Back Box:5.4"L x 3.6"W x 3.0"D(137 mmL x 91mm W the panel to determine maximum devices on a circuit. The low fre- x 76 mm D) quency sounder has an option to switch between temporal three or temporal four pattern,non-temporal(continuous) pattern and coded • Low Frequency Ceiling Sounder with SBBCRUSBBCWL Sur- supply within the frequency range of 520Hz ± 10% square wave face Mount Back Box:6.9"diameter x 3.9"high(175mm diame- tone. The low frequency sounder shall operate on a coded or non- ter x 99mm high) coded power supply with high and low volume settings. Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time- LOW FREQUENCY SOUNDER STROBE COMBINATION varying power source that is used on some power supply and panel outputs. The low frequency sounder strobe shall be a System Sensor L- Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three or temporal four pattern and a non-temporal (continuous)pattern.These options are set by a multiple position switch.The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply with high and low volume settings.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave lone. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/18 x 21/8-inch back box. The module shall also control two Class B circuits or one Class A circuit. The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications • Standard Operating Temperature:32°F to 120°F(0°C to 49°C) • Humidity Range: 10 to 93%non-condensing • Frequency Range:520 Hz±10% • Strobe Flash Rate: 1 flash per second • Nominal Voltage Low Frequency Sounder:Regulated 24 DC/ FWR1 • Nominal Voltage Range Low Frequency Sounder Strobe: Regulated 24 VDC/FWR1 • Operating Voltage Range: 16 to 33 V(24 V nominal) Page 2 of 3—DN-62011:B•10/2/2019 UL Current Draw and Sound Output Data Low Frequency Wall Sounder Strobe Current Draw(mA)and Sound Output(dBA) Sound Out Current Draw(mA) (dBA) Volume 16-33 VDC 16-33 FWR 16-33 V Pos Tone Setting 15cd 30cd'75cd 195cd 110cd j 135cd 185cd 15cd 30cd 75cd 95cd 110ed 135cd 185cd DC l FWR 1 Temporal3 High 98 115 158 173 182 212 266 136 153 188 206 228 258 304 80 80 2 Temporal3 Low 98 102 141 162 173 202 255 150 150 176 194 216 242 280 76 76 3 Temporal4 High 98 108 137 151 178 202 252 200 198 169 188 212 242 290 80 80 4 Temporal4 Low 102 104 122 136 163 187 237 176 174 154 173 197 227 275 76 76 5 Continuous High 141 158 198 216 234 264 305 190 207 249 268 289 321 368 80 80 6 Continuous Low 120 128 179 196 215 244 285 165 182 226 244 266 297 342 76 76 UL Max. Low Frequency Sounder Current Draw(mA RMS) Sound Output Current Draw (dBA) (mA) Reverberant Volume 16-33 Volts 16-33 Volts Pos Tone Setting DC FWR DC FWR 1 Temporal 3 High 108 150 80 80 2 Temporal 3 Low 78 76 76 76 3 Temporal4 High 111 151 80 80 4 Temporal 4 Low 80 76 76 76 5 Continuous High 111 151 80 80 6 Continuous Low 80 76 76 76 7 Coded High 111 151 80 80 8 Coded Low 80 76 76 76 *NOTE:For coded tones,temporal coding must be provided by the NAC.If the NAC voltage is held constant,the sounder output will remain constantly on.Coded ratings provided are for continuous voltage. IS® N161NMRIN6 S MANIMCIORIN6 QUALITY SYSTEMS This document is not intended lobe used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or amidpate all requeemenls. NI specrecations are subject to change without notice NDTI FIER FisrScar.,NOTIFIEIiB,System Senerate. rsi System Sensory are regist22o fraoarnarks of and Syrr•Circuit1"is a trademark of Honeywell 12 Clintonville Road Ir emakon I me Northford,CT 06472 G.x tot r mrefma International Ins.All lOts reserved Unawlmrized NOT 1 F 1 E R 203.484.7161 nsc a Ms,banner's sv ally prohibited. www.notitier.com Country of Origin:Mexico by Honeywell Ale iEt „„%,. SRD ACE-11 System Record Documents J. BY SPACE AGE ELECTRONICS Store important system documents in a secure location with a cabinet built specifically to meet the SYSTEM RECORD $ requirements of NFPA 72 7.7.2.4. DOCUMENTS �; �€ The number one at goal Space YOUR Age is to manufacture code LOGO compliant solutions, and the SRD is just that. NFPA 72 7.7.2.1 states, "With every new system,a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." The SRD includes our innovative 8GB flash drive slide tab that allows the user to select a USB-C or Micro USB connector to access records electronically(See NFPA 72 7.5.6.7). so oWN`o FEATURES wool • 18 gauge cold rolled steel SPECIFICATIONS SixceJ� construction with red powder coat and white The SRD System Record Documents Box shall be UL Listed, lettering constructed of 18 gauge cold rolled steel. It shall have a 114) • powder coat finish.The cover shall be permanently screed with Dimensions are 12" wide x 13"tall and 2 1/4" deep 1" high lettering "SYSTEM RECORD DOCUMENTS"with white LISTED • indelible ink.The access door shall be locked with a 3/4" barrel Stainless steel piano hinge lock and there will be a 12"stainless steel piano hinge.The SRD �� • Two key ring hooks to hold will have a minimum of 8 gigabyte digital flash memory drive system keys with a slide tab that allows user to select USB-C or Micro USB FIRE connector for uploading and downloading information.The • Business card holder for key enclosure will supply 4 mounting holes. Inside will contacts accommodate standard 8 1/2"x 11" manuals and document • Slide tab allows user to records. A legend sheet will be attached to the door for system select USB-C or Micro USB required documentation, key contacts and system information. connector to download The enclosure shall also provide 2 key ring holders with a from 8GB digital flash location to mount standard business cards for key contact memory personnel. • DCD Computer Desk Kit (sold separately) holds CUSTOM COLORS AND BRANDING AVAILABLE enclosure door open at a 90 degree angle with a snap on cable for a convenient YOUR YOUR YO YOUR YOU working surface in the field. LOGO L• O L R} R: O' L �•, O ?LOGO` Includes velcro strap for securing your laptop. Pg. 1/2 AGEBOX DIMENSIONS 2 35 1 ...._12.00 .75 10.25 ' 1.63 ZWITEN RECORD 8 9.75 � 13.00 12.59 13.16 1.63 8 l !p.25-S ..__. _...... 11.75 ORDERING INFORMATION P/N#SSU00689 SRD System Record Documents Box- Red P/N#SS000690 SRD System Record Documents Box- Red with your custom screened logo P/N#SSU01689 SRD System Record Documents Box- Black PIN#SSU01690 SRD System Record Documents Box- Black with your custom screened logo P/N#SS000616 DCD Computer Desk Kit www.isae.com I toll free 1.800.486.1723 I fax 508.485.4740 ©Copyright 2018 Space Age Electronics,Inc. This document subject to change without notice LT1 D641 Rev.E XE NFPA ./'J? ADA Pg.2/2