Report SSimpl©c System Batteries,Sealed Lead-Acid with Applications Reference for Battery Cabinets,and Battery Cabinets with Charger Battery construction reference Actual appearance varies with battery size. 1 B A ) QD 0 1------I [ IGO f\1D = --. dos 1111D : / e o i Figure 3:Battery contruction reference Callout Description Callout Description A ,Quick connect or post type terminal.Type varies with B Sealed outer cover ------ i lbattery size. • C Vent hole D Potting material,black for negative,red for positive.Polarity is also clearly marked with+and-. E Pressure relief valve F Semi-permeable membrane separator G Cell case,high impact polystrene H Lead-calcium grids -_,I I Cell group J Absorbent separator used to immobilize electrolyte K (Inner cover - I- i Battery size specifications Battery model Capacity at 20 hour Width* Depth* Height with terminals Approximate weight* discharge rate 2081-9272 6.2 Ah 6.12 in.(156 mm) 2.65 in.(68 mm) 4 in.(102 mm) 5.75 lb(2.6 kg) 2081-9286 7.0 Ah 6.12 in.(156 mm) 2.65 in.(68 mm) 4 in.(102 mm) 5.75 lb(2.6 kg) 2081-9274 10 Ah 6 in (153 mm) 4.06 in.(103 mm) j 4 in.(102 mm) i 9.2 lb(4.2 kg) 2081-9288 - 12.7 Ah 6 in (153 mm) 4 in.(102 mm) 4 in.(102 mm) 9 Ib(4.1 kg) 2081-9275 18 Ah 7.25 in.(184 mm) 3.38 in.(86 mm) 6.63 in.(168 mm) 1 14.3 lb(6.5 kg) 2081-9287 25 Ah 16.63 in.(168 mm) 5 in.(127 mm) 7 in.(178 mm) 19.41b(8.8 kg) •2081-9271 (rectangular case,typically for 33 Ah 12.5 in.(318 mm) 3.38 in.(86 mm) 7.06 in.(179 mm) 26.6 lb(12.1 kg) service) 2081-9276(square 33 Ah 1 7.75 in.(197 mm) 5.25 in.(133 mm) 6.75 in.(171 mm) 26.5 lb(12 kg) case,use for new) ;2081-9296 1, 50 Ah i 9 in.(229 mm) 5.5 in.(140 mm) 8.88 in.(225 mm) 41.8 lb(19 kg) h2081-9279 - 110 Ah 11.38 in.(289 mm) 10.5 in.(267 mm) 9 in.(230 mm) 82 lb(37 kg) *Dimensions and weight are per battery and are for reference only.Exact size may vary.Refer to Battery compatibility for FACU mounting and External battery cabinet compatibility reference for mounting compatibility.Batteries are 12 V each and connected in series for 24 V system use. Note:When wired in series for 24 V output,these batteries are to be of identical voltage,appearance,model number,and have approximately the same date of manufacture. Page 2 52081-0006 Rev.26 02/2021 5Simplex 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Example display screens r— FRISTMOOx � ,- Y� ° 2ONF{ZNIp01, 1 1ALAL A FLOOR EAST F4T14At H.: Y fl1nN aNIJP GLm FAA MONITOR ZCMI I:ai['.[c '„.,YL,I eAT .n` ra 1IR53 FLOOR `2014EI2N10011 lilt ALMIJ ter A•Leas Lew1 lamp RH OM 4TH FLOM EAST SEP 39,2019 6 38 PO FIRE MONITOR 2CAE 1114 PLPRM J LANGUAGE L PNGVPGF SWITCH S WITCH Mil MANUAL EVAC ® i LAMP TFST 'Mat" O 0 SI o JB G Figure 3:First and Most Recent Alarm Display Figure 4:Main Menu (TROUBLE IN SYSTEM MINUS LIST FL•t SYSTEM TIME/DATE INVALID OR NOT SET IAN 1.1997 1249 AN ZNIC01 FIRST FL..7R ^x. PSI Mall:,YUI NI ABNORMAL i ZN1002 SECOND FLOOR ''2 of 16 COLD STARTIAN 1 199712:49 AM P32 TROUBLE PONE ABNORMAL 1n - \ - - 2N1003 THIRD FLOOR ZONE AU} 3 of 16 CARD 6,TOUCH SCREEN DISPLAY IAN1 199112:50 AM 6.6 II fAND MISSINWIAULED AaHCR34AL I =ZN1004 FIRST AND SECOND FLOOR xCC: I 4 of 16 CARD 3.TOVCx SCREENDWPLAY IAN11997125D OR I -ZN1005 ZN1005 3-EIS IV.PMotlTIUmper In/H/id Ail MAL A=�-25/��� 12500 ® ZN1006 ZN1006 ^reenrt :RDL _,. 501 I6 CARD A ES'WISM 1R INTERFACE IAN1 1997 12 50 AM Mt 1-6-9 LARD HISSING FAILED pBNGryyI 110 i ZN1007 ZN1007 :ACE 6 o0 36 GCARD 3,NEPA TOUCH SCREEN DEiPLAY IAN 1 1992 R TROUBLE 5-93 GENERA1 TROUBLE TRwELE♦ ZN3008 2N3008 vZ 7 of I6 DP TRIM II) PN 1.199712'SB W` 1 ..ZN1009 ZN1009 PS20 TROUBLE POIN• A/HDRMnt 6 of 16 DIE TR6L 13) AN Il 1» 1H PM 773 I : ,1 :.: ---- 1 LANPTESl P523 TROUBLE POINT ABNORMAL hill ® ACX lO Sl. iiiii Figure 5:First Eight Active Trouble Events List Figure 6:Direct Point Callup I ENTRY IB 1:25:21 am WED 01-JAN-97iti6j 'sI, - - - - - -e.'.... - TAD UREA 4- 5WFT[N SECOND FLOOR - POINT ADDRESS. 4 1 3 TYPE: AY i,ZONE FIRE ALARM j CARD: 4 CHAfINEL: I DEVICE: 3 ENTRY 17 125.21 am WEL)019AN-9] I IDN0.0 CARD isp us ER.:. WITCx 3 SECOND FLOOR WEST UNIT NUMBER: 8 RUI RIMER: LOCAL I PULL STATION FIRE ALARM ARIMARY STATUS OF ENTRY 16 1:25.17 am WED 01-JAN-97 I ENABLED STATE ENABLE - E SWITCH 3 4TH FLOOR EAST RELAY STATUS OF I FIRE MONITOR ZONE FIRE ALARM CONTROLYSTATUS AUTOMATIC CONTRO ENTRY IS 1:25.15 am WED 01-JAN-9T ® AUDIBLE GROUP CONFLG B 0 75OU5ER FIRST AND SECOND FLOOR VISUAL GROUP CONFIG B B swrtcHP (ZONE FIRE ALARM ) OPEMTION 00 GENERAL i'V'"' ENTRY 19 125:15 am WED 01-JAN-97 LANGUAGE 9 CANDELA MYTHS 15 C ISO USER SECOND FLOOR swrtcH TO ERTYPES BROADBAN SWITCH 3 ZONE FIRE ALARM 1 COOING TYPE TEMPURA , VOLUME NIG ENTRY 13 1:2k15 am WED O1-JAK9T LAST TEST TINE: THU 24-MT-19 12:55 p a i'I CII S SECOND FLOOR EAST UST VISUAL TEST: NORMA I PULL STATION FIRE ALARM r UST AUDIBLE TEST: NORMA LAST TEST VOLUME NORMA 11 '*t ® DEVICE TEST TROUBLE: NORMA 1-1-ii MI J cm., A=N. Sy tt Figure 7:Alarm History Log Figure 8:Detailed Point Status Screen for TrueAlert ES Appliance Page 7 S4010-0004 Rev.26 06/2022 Qi Simplex 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Specifications Table 2:General ES Touch Screen Display Specifications Specification Luting Resolution 800 x 600 Pixels(RGB) Size/Type 8 inch(203 mm)Diagonal/Color Touch Screen Touch Screen Technology Resistive Event Display 'Up to 8 Events without scrolling Normal Screen Custom Watermark File Format 680 x 484 Pixels:BMP,JPG,TIFF,GIF or PNG file format Environmental Operating Temperature:32°F to 120°F(0°C to 49°C) Operating Humidity:Up to 93%RH,non-condensing at 90°F(32°C) maximum Operator Interface with Monochrome 2 x 40 LCD • Provides convenient and extensive operator information using a logical,menu-driven display • Multiple automatic and manual diagnostics for maintenance reduction •Alarm and Trouble History Logs of up to 1250 entries for each,2500 total events,are available for viewing on the LCD screen,printing on a connected printer,or downloading to a service computer • Convenient PC programmer label editing • Password access control FIRE ALARM ACK acknowledges a Fire Alarm condition,logs the acknowledge,and silences the operator panel and all annunciator tone-alerts PRIORITY 2 ACK acknowledges a Priority 2 Alarm condition,logs the acknowledge,and silences the operator panel and all annunciator tone-alerts SUPY ACK acknowledges system supervisory 'ULC SYSTEMS (S SYSTEM STATUS INDICATOR LEDs provide conditions,logs the acknowledge,and silences the require designating system status Indications,LEDs flash to indicate operator panel and all annunciator tone-alerts a Ground Fault a change in status and remain on-steady after TROUBLE ACK acknowledges system trouble indicator acknowledged until reset conditions,logs the acknowledge,and silences the • operator panel and all annunciator tone-alerts ALARM SILENCE causes audible notification 2 X 40 LCD READOUT,LCD is appliances to be silenced(depending on control unit 3 PROGRAMMABLE LEDs backlighted during normal conditions, programming)typically after evacuation is complete and two selectable as Red or Yellow, provides up to 40 characters nor custom while alarm source is being investigated;may allow one selectable as Green or Yellow label information visible notification to continue(strobes Mil flashing) (iFIRST ALARM DISPLAY operation can SYSTEM RESET restores control unit to normal when Custom label insect be selected for maintained display of first all alarmed inputs are returned to normal \i alarm until acknowledged I ---• - SY:3TEPI IS NOliMAL 1 .Z:2� 15 as FR 04] v:::- 2 S �_ 2 3 • ® ALARMS WARNINGS 1——_ ® ACK ACK SLACK ACK ='L•rn •'1�I 7 8 9 • C mlacenneer ii • alElevator Brpasa IIiiii rn.." ."'"' -.wee ii ,.-_-• 111 GrL d,un • r Simplex FirE/Control ``. 4010 - 3 PROGRAMMABLE POINT STATUS ADDITIONAL FUNCTION LCD NAVIGATION NUMERIC KEYPAD for FUNCTION SWITCHES CONTROL KEYS: KEYS: CONTROL: point category and point with yellow LED Point Enable and Event Time Request Menu selection selection(alphabet indicators Disable More Information Request Vertical and characters are not used at .v Force On or Arm Lamp Test Horizontal position this time) Force Off or Disarm selection buttons Return ONOff or Arm/Disarm to Auto Mode Figure 9:Operator interface features Page 8 S4010-0004 Rev.26 06/2022 EiSimplex 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Basic control unit model selection,one-bay units Supervisory and alarm current specifications are for determining battery standby requirements.Current specifications include an active RUI channel. Models with an IDNet channel include 20 IDNet device LEDs activated in alarm.Actual IDNet device current is not included.For models with 48 LED annunciation,alarm also includes 24 LEDs activated. Table 3:Basic Control Unit Model Selection-1 Bay Units Model Panel color Language and Listings Features Supv. Alarm Available voltage current current option blocks 4010-9401 Basic control unit with 2x40 i4010-9401 BA fedi UL, LCD Operator Interface and one two-loop isolated IDNet2 4010 9402 English 120 VAC CSFM,FM, Communications Channel,Class A 316 mA 430 mA I Platinum INYC Fire Dept or Class B operation,with support 4010-9402BA for up to 250 addressable analog • Three 4 in.x 5 in. • devices blocks 4010-9403 Red UL,ULC, •4010-9404 Platinum English 120 VAC CSFM,FM, NYC Fire Dept Same features as above with 48 LED 336 mA 495 mA 4010-9405 Red 1 annunciation 4010-9406 Platinum French 120 VAC ULC,CSFM FM Note:Model numbers ending in BA are assembled in the USA. Basic control unit model selection,two-bay units Supervisory and alarm current specifications are for determining battery standby requirements.Current specifications include an active RUI channel. Models with IDNet channels include 20 IDNet device LEDs activated in alarm for each channel.Actual IDNet current is not included.See Addressable device load specifications for battery standby for details. Table 4:Basic Control Unit Model Selection-2 Bay Units Language& Available Supv. Alarm Model Panel Color Voltage Listings Features Option Blocks Current Current 14010-9421 3asic control unit with 2x40 '4010-9421 BA Red English 120 VAC Operator Interface,one two-loop — isolated IDNet2 Communications Channel and one four-loop UL,FM 391 mA 545 mA 4010-9422 Isolated IDNet 2+2 Communications Platinum English 120 VAC 4010-9422BA Channel Module,Class A or Class B operation,with support for up to 500 addressable IDNet points 4010-9423 Red English 120 VAC Same features as above with 48 LED i • annunciation I • Same features as above with 48 LED 4010-9428 !Platinum English 120 VAC UL,ULC,FM 10 4 in.x 5 in. 411 mA .610 mA annunciation :!blocks 4010 9430 'Platinum French 120 VAC Same features as above with 48 LED annunciation 1Basic control unit with ES Touch MI20tVAe.C. !Screen Operator Interface and Ian ua es one two-loop Isolated IDNet2 g g Communications Channel,one B l are available, UL/ULC, I 4010-9435 Red ifourdoop Isolated IDNet 2+2 1486 mA 661 mA contact your CSFM Communications Channel Module, !local Simplex i Class A or Class B operation,with I • product supplier support for up to 500 addressable i for details. IDNet points 1 1I ending in BA are assembled in the USA. 1 Note:Model numbers Page 9 54010-0004 Rev.26 06/2022 f3SImpIEx • 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Miscellaneous accessories Table 5:LED kits Model Description 4010-9831 French Applique Kit for ES Touch Screen isplay Panels,order separately as required for Canadian French panels 4100-9843 8 Yellow LED Kit 4100-9844 18 Green LED Kit 4100-9845 I8 Red LED Kit 4100-9855 8 Blue LED Kit 4100-0650 Battery shelf,required for 50 Ah batteries,in two-bay cabinets only Note:LEDs are pluggable.Use LEDs to change color for local application requirements Table 6:Factory Programming Tools Model Description 4010-0831 - a ry programming programming,requires 4010-8810 4010-8810 Fa 1 do ramming(select) Custom labels and General specifications Table 7:General specifications Specification Rating AC input current 120 VAC models 4A maximum,120 VAC at 60 Hz nominal Power supply output ratings Total power supply output Including module currents and auxiliary power outputs; Output switches to (nominal 28 VDC on AC,24 rating 8 A total for Special Application appliances;4 A total for battery backup during VDC on battery backup) Regulated 24 DC power,see below for details mains AC failure or Auxiliary 49o1 r tap 4904,and 4906 A maximum,rated 19.1 VDC to 31.1 VDC brownout conditions ryP P Special application 4906 series horns,strobes,and combination horn or strobes and speaker or appliances,maximum of 70 strobes.Contact your Simplex product representative for compatible appliances. a appliances for each NAC Regulated 24 DC appliances Power for other UL listed appliances;use associated external synchronization modules where required Battery capacity range See data sheet Batteries and Battery Cabinets;110Ah Sealed Lead-Acid Batteries and Battery charger rating(sealed Compatible Battery Cabinet(without charger)(S2081-0012)for further details. lead acid batteries) (Charger characteristics and ;Temperature compensated,dual rate,recharges depleted batteries within 48 hours performance per UL Standard 864;to 70%capacity in 12 hours per ULC Standard 5527 Battery Current 9 A maximum at 24 VDC(during battery operation) Environmental Operating temperature 32°F to 120°F(0°C to 49°C) Operating humidity Up to 93%RH,non-condensing at 90°F(32°C)maximum Additional technical Installation instructions 4010ES Fire Alarm System Installation Guide(579-989) reference Operating instructions 4010ES Fire Alarm Operator's Manual(579-969) Addressable device load specifications for battery standby Table 8:Addressable device load specifications for battery standby Addressable channel Load Supervisory current Alarm current IDNet2 and IDNet 2+2 Channel Device With 250 devices add 200 mA 250 mA Currents.20 device LEDs in alarm are included With 125 devices add 100 mA 125 mA with control unit and module currents With SD devices add 40 mA SO mA Table 9:Current draw for each IDNet device Condition Current Standby 0.8 mA Alarm,with LED off 10 mA • Alarm,with LED on — 3.0 mA Note:A maximum of 20 devices with LED on is supported for each channel.Additional device LEDs do not turn on. Page 10 54010-0004 Rev.26 06/2022 f Simplex 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Block space option card selection Note:Maximum block option module quantities may require 2 bay cabinets,1 bay cabinets are limited to 3 option block spaces total.See Figure 10 for option module space availability.Supervisory and alarm current specifications for determining battery standby requirement consider no load on addressable channels except as noted,see Addressable device load specifications for battery standby. Table 10:Single block option modules Model Features Supervisory Alarm Option block current current usage 4010-2504 ;Connected ervices Gateway with IP cator .125 125 4010-9912 Note:Mu tSmount in Block D under Main System Supply 30 mAA 40 mAA (must mount in P y top bay,block D) 4010-9908 4-Point Aux Relay Module 15 mA 60 mA 1 block (3 max) Voltage Regulator Module,22.8 VDC to 26.4 VDC(25 VDC nominal);isolated 4010-9916 and resettable output;includes earth detection circuit and trouble relay for 3 A maximum with 'maximum 1 block status monitoring.One 4010-6305 harness(see below)is required for each 2.5 A load with 4 A load (1 max) 4010-9935 or 4010-9936 module powered from the 4010-9916. I 4010-9918 Dual RS-232 Module 60 mA 60 mA block (3 max) 4010-9915 BACpac Ethernet Portal Module;requires 4010-9918 RS-232 Module(no 123 mA 123 mA 1 block address required) _ (3 max) 4010-9901 IVESDA HLI 60 mA 60 mA 1 block (1 max) 8-point z1/relay 4 in.x 5 in.flat module.Supports eight Class B or four Class A IDCs.Mounts in any open block in a master controller or expansion bay. 4010-9935 Alarm current shown is for eight Class B IDCs using 3.3 K end-of-line-resistors 83 mA 295 mA One block(11 with four IDCs in alarm and four IDCs in standby.Standby current shown is maximum) for all eight IDCs in standby.Detector current is added separately.Refer to ' Zi/Relay Module Installation Instructions 579-1236 for more information. 4010-9936 4 DPDT Relays with feedback 2A 18 mA 65 mA 1 Block(11 maximum) 25 V regulator harness for 8 point z1/relay module.1 required for each I 4010-6305 ,8 point z1/relay module to be powered by the 401 0-991 6 25 V regulator IN/A N/A N/A module.A maximum quantity of five 8 point z1/relay modules can be powered from the 4010-9916 25 V regulator module. • IDNet 2+2 Module,250 point capacity;electrically isolated No device 50 mA 60 mA output with four short circuit isolatingClass B or Class P 50 devices 90 mA 150 mA - (31 max) 4010-9929 A output loops;alarm currents for 50 and above devices 125 devices 150 mA 225 mA includes 20 device LEDs in alarm;see control unit model selection for individual device currents 250 devices 250 mA 350 mA Table 11:Dual vertical block(flat)modules,see note 2 Model Features Option block usage Supervisory Alarm current current 1 4010-9928 For 1 bay control units only:Dual Vertical Block Two vertical blocks(mounts in top bay, IN/A IN/A Card Mounting Kit,allows selecting two,dual ,block space A and B only) I Vertical Block(flat)modules from the list below; mounts at right angle to chassis(note the block usage details) 4010-9923 See note SafeLINC Internet Interface 2 Vertical Blocks 115 mA 115 mA 1 •• Note: 1. UL,ULC,and CSFM Listed. 2. For details on other dual vertical block network options refer to data sheets S4100-0029,S4100-0056,S4100-0057,ES Net Network Applications, Communications,Options and Specifications(54100-0076),and Building Network Interface Cord(BNIC)(54100-0061). Page 11 S4010-0004 Rev.26 06/2022 f3SimplEx 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Additional control unit feature selection -block space is not used Table 12:Additional control unit feature selection-block space Is not used Model Features Supervisory current Alarm current Mounting requirements 4010-9909 City Connect Module w/ 120 mA '36 mA ,Mounts on Main System disconnect switches Supply(1 max) 4010-9910 City Connect Module 20 mA 36 mA 4010-9911 Alarm Relay Module 15 mA 37 mA 4100-5128 Battery Distribution Terminal Block,mounts to side of box.Required when battery connection leaves the 4010E5 box. Also used in the 4100ES fire alarm control unit. Refer to data sheet Truelnsight Remote Service Overview and Hardware Reference(S4100-0063)and contact your local Simplex product representative for more details. Network interface and network media card product selection 4010ES fire alarm control units are compatible with Simplex ES Net network or 4120 network fire alarm products. Refer to datasheet ES Net Network Applications,Communications,Options and Specifications(S4100-0076)for additional information on compatible ES Net fire alarm products. • Refer to datasheet 4120 Network Applications,Communications,Options and Specifications(S4100-0056)for additional information on compatible 4120 network fire alarm products. • Refer to datasheet Building Network Interface Card(BNIC)Models 4100-6047 and 4010-9914(S4100-0061)for additional information on the BNIC. • Refer to datasheet Connected Services Gateway-Central Station Communication and SafeLINC Cloud Services(52080-0091)for additional information on the Connected Services Gateway. Additional 4O1OES and network product reference data sheets Table 13:Additional 4010ES and network product reference data sheets Title Doc.number r e.'' - Serial DACT(SDACT)for 4100ES,4010ES,4007ES S2080-0009 Connected Services Gateway-Central Station Communication and SafeLINC Cloud S2080-0091 Services Seismic Battery Brackets Reference S2081-0019 4003EC Voice Control Unit 54003-0002 4009 IDNet NAC Extender 54009-0002 � 4009 IDNAC Repeater S4009-0004 4010ES Extinguishing Release Applications 54010-0005 4010ES Panels with Conventional Notification(INTL) 54010-0006 4010E5 Extinguishing Release Applications(INTL) 54010-0007 InfoAlarm Command Center for the 4010E5 Panels S4010-0008 InfoAlarm Command Center for the 4010E5 Panels(INTL) _ 54010-0009 4010ES Panels with Addressable Notification S4010-0011 4010ES Panels with Addressable Notification(INTL) S4010-0012 External 110 Ah Battery Charger for 4100E5,4010ES 54081-0002 Graphic I/O Modules for 4100ES,4010ES,4007E5 54100-0005 4 Interface to VESDAAir Aspiration Detection Systems 54100-0026 NDU with SPS Power Supplies for 4120 Network 5 100-0036 InfoAlarm Command Center with SPS Power Supplies S4100-0045 Multiple Signal Fiber Optic Modems for 4120 Networks S4100-0049 BACpac Ethernet Module S4100-0051 4120 Network Products and Specifications 54100-0056 Building Network Interface Card(BNIC) 54100-0061 SafeLINC Internet Interface 54100-0062 ES Net Network Products and Specifications 54100-0076 NDU with EPS Power Supplies for4120 Network 54 1 00-0 1 02 NDU with EPS Power Supplies for ES Net 54100-0104 NDU with ES-PS Power Supplies for 4120 Network S4100-1036 Remote ES Touch Screen Displays for 4100ES and 4010E5 Panels 54100-1070 NDU with ES-PS Power Supplies for ES Net 54100-1077 TrueSite Workstation 54190-0016 - TrueSite Incident Commander 54190-0020 - - 24-Pin Dot Matrix Fire Alarm System Remote Printer 54190-0027 SCU/RCU Annunciators S4602-0001 4606-9102 Remote LCD Annunciator S4606-0002 Page 12 S4010-0004 Rev.26 06/2022 f3SimplEx 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories 4010ES card address allocation The 4010ES has a maximum internal and external card address limit of 20 card addresses.Use Table 14 to calculate 4010ES card address allocation. 1. For the applicable control unit,write in the Card Address Consumption value in the Card Address Allocation column.Select one control unit only. 2. For the option cards to be installed on the 4010ES,write in the Card Address Consumption value in the Card Address Allocation column. 3. Add together the numbers in the Card Address Allocation column.The total must not exceed 20. Table 14:4010ES card address allocation Model Description Card Address Card Address Consumption Allocation Control units(select one) 4010-9401 - ---- 4010-9401BA 14010-9402 4010-9402BA 2x40 display,(1)IDNet 2 Communications Channel,1-Bay box 2 4010-9405 I4010-9406 4010-9403 2x40 Display,(1)IDNet 2 Communications Channel,48 Pluggable LED Module,1-Bay 4010-9404 Box 4010-9421 4010-9421 BA 2x40 Display,(1)IDNet 2 Communications Channels and one IDNet 2+2 4010-9422 Communications Channel,2-Bay box i 4010-9422BA 4010-9423 4010-9428 2x40 Display,(1)IDNet2 Communications Channels and(1)IDNet 2+2 Communications 4 Channel,48 Pluggable LED Module,2-Bay Box 4010-9430 4010-9425 4010-9425BA InfoAlarm display,one IDNet+Communications Channel and one IDNet 2+2 4010-9426 Communications Channel,2-Bay box 4 4010-9426BA 4010-9435 ES Color Touch Screen Display, 1 IDNet 2 Communications Channel and(1)IDNet 2+2 4 Control unit option Communications Channel,2-Bay Box y pCcards(select as required) 4010-2504 Connected Services Gateway with IP communicator 1 4010-9901 Flat VESDA HLI Card 1 4010-9922 Flat 4120 Network Card 1 4010-6310 Flat ES Net Network Interface Card 1 • 4010-9908 • 4 Point Flat Aux Relay Module 1 • 4010-9912 Serial DACT 1 4010-9923 SafeLINC Internet Interface Card 1 4010-9914 Building Network Interface Card — — 1 4010-9918 Dual RS-232 Module 1 4010-9935 8 point zone/relay 4 in.x 5 in.flat module 1 i4010-9929 IDNet 2+2 Communications Module 1 '4010-9936 14-Point Auxiliary Relay Module with Feedback 1 Remote Annunciation(Select As Required) I4100-9401 Red Cabinet,English 2 141 00-940 3 Platinum Cabinet English 2 Remote 4100-9421 InfoAlarm ;Red Cabinet,French 2 4100-9423 "Command Platinum Cabinet,French 2 4100-9441 Center !Red Cabinet,with blank inserts for key labels 2 • 4100-9443 1 Platinum Cabinet,with blank inserts for key labels 2 4100-9404 1Remote Red Cabinet 1 .ES Touch — 1 4100-9405 Screen Platinum Cabinet Display 4606-9102 14010ES RUI LCD Annunciator,English 1 •4606-9102BA 4010ES RUI LCD Annunciator,English 1 Page 13 S4010-0004 Rev.26 06/2022 f3Simplex 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Table 14:4010E5 card address allocation Model Description Card Address Card Address Consumption Allocation 4606-9102CF 010ES RUI LCD Annuncia:or,French 1 4602-9101 Status Command Unit(SCU)LED Annunciator 1 4602-9102 Remote Command Unit(RCU)LED Annunciator w/control 1 4602-9150 Graphic I/O RCU/SCU Assembly for custom annunciator 1 4602-7101 Graphic I/O RCU/SCU Assembly for custom annunciator 1 4602-7001 RCU for cabinet mount 1 4602-6001 SCU for cabinet mount 1 4100-7401 24 Point I/O Graphic Module(requires mounting cabinet) 1 I 4100-7402 64/64 LED Switch Controller for custom annunciator 1 4100-7403 32 Point LED Driver Module for custom annunciator 1 - 4100-7404 32 Point Switch Input Module for custom annunciator 1 Total Card Addresses(not to exceed 20) TOTAL Note:Products ending with BA are assembled in the USA. One-bay and two-bay cabinet loading reference - First bay of one-bay Cabinet has 3 available , 4"x 5" Main System 4'x 5 Mein System First bay of two-bay 4"x5"block spaces for Block^ supply hIl� Block Aiy additional option cards cabinet has 3 available 4"x5' l 4'x5' 4'x5' 4"x5• 4"x5"block spaces for 'Bunke Slack Block B1 Block D I additional option cards ___ Second bay of two-bay 4'— - xs'.4•xMiexsi4-xs' cabinet has 8 additional 4" L._. Blvok AsBbck Cl'B oek E$Bbck G 1 s opir x 5"block spaces for 9 additional option cards(2 P s xS n4-x5'i'4'xr♦4'x5' &ork BliBloek D:)BbekF plod(H horizontal rows of 4 blocks) I Figure 10:Loading reference Note:Some spaces may be used by basic control unit features. Page 14 S4010-0004 Rev.26 06/2022 f3 Simplex • 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Cabinet dimension reference Front view,box outline without door Side view with door attached (See note 1) 16'(406 mm " Door thickness 4 3/4"(121mm) • Knockout screw/nail holes (for semi-flush mounting) 2 Bay height= 40"(1016 mm) A • O • Exposed cabinet for • semi-flush mounting with 1/2"(13 mm)wall: —� f Box depth, /32" 2 7/8'(73 mm)for 4"stud 8 Use 4 holes to 7/8"(22 mm)for 6"stud (1752 m mmm) Secure box to wall _1/2"(13 mm)wall board( 1 Bay height= Exposed door and cabinet reference for semi-flush 22"(559 mm) for semi-flush mounting mounting with 1/2"(13mm)wall: Stud alignment 7 5/8"(194 mm)for 4"stud markers,each side 5 5/8"(143mm)for 6"stud 6"stud (4"stud] Reserved for Batteries d ri V V Total depth, �, box and door e 24"(610 mm) id 11 11/18" is(296 mmj 1.11 Figure 11:Cabinet dimension reference Note:Side view dimensions are shown with minimal cabinet and door protrusion from the exterior wall.For 6 in.stud construction with minimum protrusion shown,the door will open 90 degrees.To allow the door to open 180 degrees,the exposed cabinet dimension from the exterior wall must be a minimum of 3 in.(76 mm)for both 4 in.and 6 in.stud construction. • Page15 S4010-0004 Rev.26 06/2022 • DSimplEx System Accessories, LCD Annunciators UL, ULC, CSFM Listed; 4606-9102 LCD Annunciator FM, NYC Fire Dept Approved` for 4010ES Fire Alarm Control Panels Features Remote LCD annunciator for use with Simplex® ce •, model 4010ES fire alarm control panels IT LCD readout provides: �._ 12125g:IS amIS THUU 0YNN.L2-A50-12 • Two lines of 40 characters each • • • Wide viewing angle,super-twist design _ _ • LED backlighting ssi,,,p•„ Control switches and status LEDs for: • Alarm,Priority 2,Supervisory,or Trouble 4606-9102 LCD Annunciator acknowledge(keyswitch access controlled) • Alarm silence,System reset Description (Continued) • Three programmable control switches with yellow LEDs and provisions for custom labeling Indications.Alarm,Priority 2,Supervisory,and Trouble Additional features: conditions are also indicated by dedicated LEDs and a • Information is transmitted over a single unshielded tone-alert audible indication.Each condition has a twisted pair;separate wiring is required for 24 VDC dedicated acknowledge push-button switch that silences control panel power(see p.3 for more information) the tone-alert but leaves the LED on until all conditions in that category are restored to normal. • Tone-alert sounder provides local audible indication • Lamp and LCD are functionally tested each time the Activity Scrolling.Repeated operation of the keyswitch is turned on appropriate acknowledge switch will scroll the LCD display showing activity in the sequence of occurrence. • Mounts flush on standard 6-gang electrical box The internal tone-alert also sounds to indicate the • Up to up to 20 internal and external card addresses per operation of any of the push-button switches. 4010ES fire alarm control panel Mounting and trim options (ordered separately, Operation see page 3 for more details): Keyswitch Access.All switches on the annunciator are • Surface mount box model 2975-9206 controlled by the"ENABLE"keyswitch with a key that is • Brushed stainless steel trim model 4603-9111 removable only in the disabled position.A brief Lamp/LCD test is performed whenever the keyswitch is Descri lion changed from enabled to disabled. Enabled Operations.When enabled,notification Local Annunciation.4606-9102 LCD Annunciator appliances can be deactivated by pressing the"ALARM allows 4010ES fire alarm control panels to provide SILENCE"switch.Pressing the"SYSTEM RESET" information and control switches at convenient locations switch restores the system to normal operation.When away from the control panel.The LCD is an 80 character, system activity is normal,the LCD displays the time, back-lit,alphanumeric display with information presented date,and"SYSTEM IS NORMAL." in clear and descriptive English.Typical content includes: point status(alarm,trouble,etc.),alarm type(smoke detector,manual station,etc.),number of system alarms, supervisory conditions,troubles,and custom location labels up to 40 characters long. Communications.Data communications require a single unshielded twisted pair that supports other annunciators on the same communications channel • This product has been approved by the California Stale Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safely Code.See CSFM Listing 7300-0026:0370 for allowable values and/or conditions concerning material presented in this document It is subject to re-examination,revision,and possible cancellation.NYC Fire Dept COAf16095.Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the properly of Tyco Fire Protection Products. S4606-0002-7 8/2016 Product Selection Model Description 4606-9102 Remote LCD Annunciator with beige trim for use with 4010ES fire alarm control panels Refer to specifications on page 3 4603-9111 Brushed stainless steel trim option for additional details 2975-9206 Matching surface mount box; ivory finish 2081-9044 Overvoltage protector; required where annunciator communications and power wiring exits and enters a building; refer to data sheet S2081-0016 for details 4606-9102 Operator Information 2 X 40 LCD READOUT,green LED backlighted during normal conditions and abnormal operating conditions SIX STATUS INDICATOR LEDs provide system status . indications in addition to LCD information; LEDs flash to indicate the condition and then when acknowledged, [THREE PROGRAMMABLE(Yellow) remain on steady until reset; Fire Alarm and Priority 2 LEDs,each with pushbutton switch and Alarm are red;System Supervisory,System Trouble, custom labeling pocket `and Alarm Silenced are yellow;Power On is green DISPLAY TIME SYSTEM IS NORMAL displays time of last - 12:25:15 am TUE 10-JUL-12 A occurrence of event FIRE PRIORITY SUPERVISORY SYSTEM POWER , gaen list being displayed; ALARM ALARM 9U SYSTIEM TROUBLE ON cAl or displays current • • • • S • time when viewing I 0 il fi . I aullir. system status information f3 Sim• -x ALARM ACK/FIRE ALARM acknowledges a Fire Alarm condition and silences the SYSTEM RESET restores panel and all annunciator tone-alerts control panel to normal CONTROL ENABLE when all alarmed inputs ALARM ACKIPRIORITY 2 acknowledges KEYSWITCH are returned to normal a Priority 2 Alarm condition and silences controls all switch functions; ` the panel and all annunciator tone-alerts key is removable only in disabled position SUPV ACK acknowledges System ' Supervisory conditions and silences the ALARM SILENCE causes audible and panel and all annunciator tone-alerts visible notification appliances to be ` silenced(default operation,may be TROUBLE ACK acknowledges modified through panel programming for System Troubles and silences the compliance with local requirements) panel and all annunciator tone-alerts 2 S4606-0002-7 8/2016 4606-9102 LCD Annunciator Specifications General Operating Specifications (refer to Installation Instructions 579-977 for additional information) Voltage 18 to 32 VDC, system supplied Normal Operating Current 110 mA(with LED backlighting on) Battery Standby Current 65 mA(during battery backup, LED backlighting is turned off after 30 seconds without switch activity) Alarm Current 140 mA maximum (LED backlighting is on and tone-alert is sounding) Operating Temperature Range 32°to 120° F(0°to 49°C) Operating Humidity Range Up to 93% RH, non-condensing at 100° F(38° C) Communications RUI (Remote Unit Interface)external annunciator communications line SLC For 4010ES Panels* Type (signaling line circuit) Capacity Up to 20 total internal and external card addresses Wiring Requirements Standard Wiring Type Unshielded twisted pair(UTP), 18 AWG (0.82 mm2)for most applications, see below Wiring Characteristics 0.58 NF(580 nF)maximum capacitance between conductors; 35 C2 maximum total line resistance 1. Wiring that leaves the building.Also requires Isolated Loop Circuit Protectors on each end, refer to data sheet S2081-0007 for 2081-9027(200 mA), or Wiring Applications S2081-0008 for 2081-9028(5 A) RUI Data Requiring Shielded, 2. Wiring run in 500 ft(152 m)or more of conduit. Twisted Pair(STP) 3. Wiring closely bundled with standard IDNet communications or TrueAlert addressable communications(not required when run with IDNet+ communications). Class B"T-Tap"wiring Up to 10,000 ft(3048 m)total wiring; up to 2500 ft(762 m)to farthest device distance Class X wiring distance Up to 2500 ft(762 m) Power Wring 18 to 12 AWG (0.82 mm2 to 3.31 mm2)wires for 24 VDC system power A dedicated earth ground connection to the electrical box is required for proper ESD Earth Wiring and EMI protection;wire in accordance with NFPA 70(National Electrical Code) Article 250 Mounting Information Trim Dimensions 4'/2° H x 11 13/6 W(114 mm x 300 mm) Assembly Depth 1 5/s' (33 mm), 1 '//' at terminal block location(38 mm) Standard Trim Finish Steel, painted beige 4603-9111, Optional Trim Brushed stainless steel(ordered separately); supplied with both slotted and tamper resistant screws Boxes for Masonry boxes Six-gang box, Steel City GW-635-G, 3'h' (89 mm)deep or equal Flush Single gang boxes Six, single gang boxes, 3 %"(89 mm)deep minimum, RACO#590 or equal Mounting (supplied Box selection note Conduit entrance is box dependent, refer to Installation Instructions 579-977 for separately) additional mounting information and conduit entry requirements 2975-9206, Surface Mount Box Option (ordered separately) Dimensions 12"Wx4%" Hx2'/." D(305mmx117mmx70mm) Finish Painted steel, ivory finish * Refer to the 4010ES control panel data sheet for additional panel information. 3 S4606-0002-7 8/2016 5 Simplex - System Batteries,Sealed Lead-Acid with Applications Reference for Battery Cabinets,and Battery Cabinets with Charger General battery specifications Nominal Voltage Rating 12 V Discharge Rating 20 hour rate Typical Charge/Discharge Cycles 100 cycles to 150 cycles - Preferred Charge Temperature Range 60°F to 90°F(15.6°C to 32.2°C) Battery compatibility for FACU mounting Note:Refer to individual FACU product data sheets for additional battery application information. Table 1:Battery compatibility for FAO)mounting Simplex FACU model series Battery Capacity 4003EC 4004R 4007ES 4006& 4009(all 4010 4010E5 4100ES/ 4100&4120 Model &4005 4008 models) 4100U (2,4 or 6-Unit) 208"-9272 6.2 Ah Yes Yes Yes Yes Yes Yes Yes Yes Yes 2081-9286 7.0 Ah Yes '1Yes Yes Yes 'Yes Yes Yes Yes Yes 2081-9274 '10 Ah Yes Yes Yes Yes Yes Yes Yes Yes Yes 2081-9288 12.7 Ah Yes Yes Yes -Yes Yes Yes 'Yes Yes Yes 2081-9275 18 Ah Ext Note 3 Yes Ext Ext Note 2 Yes Yes Yes =1r 25 Ah Ext 1Note 3 Ext Ext N/A Yes Yes Yes Yes 2081-9271 33 Ah Ext Note 3 Ext N/A N/A Note 3 Yes Yes Ext rectangular 2081-9276 33 Ah Ext Note 3 N/A N/A N/A Note 3 Yes Yes Yes square 2081-9296 SOAK N/A Note 3 N/A N/A N/A Note 3 Note 4 2 or 3 bay i Ext 2081-9279 110 Ah Requires external battery cabinet,compatible with 4100E5,4010E5,4100,and 4120 Series only Yes=Compatible with included FACU cabinet. Ext=Requires external battery cabinet,refer to External battery cabinet specification reference. Note: 1. These batteries meet the requirements of UL,ULC,and Factory Mutual for use with respective equipment battery chargers listed above.Contact your local Simplex product supplier for proper battery selection per system requirements. 2. 4010 Cabinets accommodate 2081-9275,18 Ah batteries,but do not allow bottom entry conduit. 3. Use 4081 series companion cabinet and charger,refer to External battery cabinet specification reference. 4. For two bay cabinets only,50 Ah batteries will fit in the cabinet. External battery cabinet compatibility reference Table 2:External battery cabinet compatibility reference Battery cabinets without chargers,connected to FACU charger Cabinet Panel Battery compatibility 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 18 Ah* 18 Ah* 'Rectangular 33 Ah Square' 33 Ah 50 Ah 1110 Ah 2081-9280 —14100ES,4010ES, 1 _-_- 4100U,and 4100+ N/A N/A N/A N/A N/A Yes 2081-9281 multiple Yes Yes Yes ,Yes Yes N/A 2081-9282 4009-9801 'multiple Yes Yes** N/A 'Yes N/A N/A Table 3:External battery cabinet compatibility reference Battery cabinets with chargers Cabinet Panel Battery compatibility i,2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 18 Ah* 18 Ah* Rectangular 33 Ah Square 33 Ah Square 50 Ah 110 Ah 4081-9301 4004R and 4010 Yes Yes Yes Yes Yes N/A 4081-9302 4081-9306 4100E5,4010ES 'N/A IN/A N/A N/A Yes IYes 4081-9308 and 4100U *Batteries smaller than those listed are normally mounted in the product cabinet **25 AH capacity is effective as of 7/2005 Yes-Compatible with included FACU cabinet Page 3 S2081-0006 Rev. 26 02/2021 gSimploc System Batteries,Sealed Lead-Acid with Applications Reference for Battery Cabinets,and Battery Cabinets with Charger External battery cabinet specification reference Table 4:Battery cabinets without chargers,shallow design with front door Model Color Listings Description Dimensions 2081-9281 Beige UL and CSFM 25.75 in.W x 20.75 in. H x 2-Unit,4100 style cabinet without charger;with locking solid door and 6.75 in.D(654 mm x 527 mm 2081-9282 Red UL 1battery shelf,primarily for use with 50 Ah batteries x 171 mm) * For use with 4003EC systems,for batteries up to 33 Ah(refer to 4003EC 9.5 in.H x 24 in.W x 9 in.D 4003-9860 Beige FM data sheet 54003-0002) (241 mm x 610 mm x 229 mm) UL,ULC,and External battery cabinet without charger, 16.25 in.W x 13.5 in.H x 5.75 4009-9801* Beige FM For batteries up to 33 Ah with locking solid door and battery harness; in.D(413 mm x 343 mm x for close-nippled mounting to FACU cabinet 146 mm)* Depth increased for 2081- 9276 square 33 Ah batteries effective 7/2005. Table 5:Battery cabinet without charger,deep design with hinged lid Model Color Listings Description Dimensions Battery cabinet without charger;cabinet 26.5 in.W x 12 in H x 12 in D(673 mm x 2081-9270 ,Red UL has vented front,and hinged lid with 1305 mm x 305 mm) support rod and lock on top Table 6:Chargers for use with 4010 FACUs and 4004R suppression release systems,refer to data sheet 54081-0001 Model Color i Listings Input Description Dimensions voltage j • 4081-9301 Beige Battery cabinet with charger for the 4010 and 22.5 in.W x 16.75 in.H x 8.38 in.D 4081-9302 Red UL and FM '120 VAC j4004R FACU,for batteries up to 50 Ah,with (572 mm x 425 mm x 213 mm) front Table 7:Battery cabinet without charger for 110 Ah batteries,for use with compatible FACU mounted chargers,refer to data sheet 520814012 Model Color 44A.Ajstings Cabinet description Compatible Charger description 1 Dimensions and listing ..7: r, chargers 4100-9xxx 4100ES/41000 Power Supplies Series for Master Controller/CPU Bays 4100-5401 4100ES Additional ES Power Supply(ES-PS) 4100-5111 1 4100-5113 4100ES/41000 Additional SPS Battery cabinet without charger 4100-5311 4100ES Additional EPS+ 4100-5313 26.5 in,W x 12 forZ081-9279,110 Ah batteries. in.H x 12 in.D 2081-9280 RedI UL,ULC,CSFM Includes 80 A battery fuse, 4100-5325 4100ES Additional EPS terminals and battery connection 4100-5327 (673 mm x 305 cables.See data sheet for details. 4100-5125 14100ES/41000 Remote Power mm x 305 mm) 4100-5127 ,,Supply(RPS) 4100-5120 i4100ES/41000 TrueAlert 4100-5122 Addressable Power Supply(TPS) 4100-0104 I 4100-0114 4100 le a g n'power supplies l 4100-0124 Table 8:Battery cabinet with charger for 110 Ah batteries,for use with compatible FACU mounted chargers,refer to data sheet 52081-0012 Model Color Listings Input voltage Description Dimensions 4081-9306 Red UL ULC,FM,MEA 120 VAC 27.88 in.W x 13.5 in. (NYC) Battery cabinet with charger for batteries up H x 14.63 in.D(708 4081-9308 220/230/240 to 110 Ah .mm x 343 mm x 371 Red UL,ULC,FM VAC,multi- mm) tapped i 4100-9837 Green LED Power-on Indicator Kit,required for ULC listing,mounts above access panel using knockout provided ©2022 johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable,contact your local Simplex®product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.Simplex, and the product names listed in this material are marks or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). S2081-0006 Rev.26 02/2021 �3 SimplEX Da et. 4010ES Fire Controlol Units UL,ULC,CSFM Listed;FM,NYC Fire 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Dept Approved* Features Compatible with Simplex ES Net and 4120 fire alarm networks Basic system features: • Models available with Color ES Touch Screen Display or Monochrome 2 line x 40 Character Display • Capacity for up to 1000 addressable IDNet points,up to 127 VESDA Air Aspiration points,up to 2000 points of annunciation,and up to 20 - internal and external card addresses • CPU assembly includes dedicated compact flash memory for on-site system information storage and convenient Ethernet service port access • 8 A power supply with up to 2 A of auxiliary power and battery charger capacity for up to 110 Ah batteries(UL)or up to 50 Ah batteries (ULC),33 Ah max in single bay control cabinet 50 Ah maximum with 4100-0650 battery shelf in two-bay control cabinet • Four onboard Class A or B,3 A notification appliance circuits(NACs) and one programmable auxiliary relay output rated for 2 A at 32 VDC • IDNet addressable device communications that support TrueAlarm analog sensors and IDNet communications monitoring and control devices with an electrically isolated output channel allowing use with either shielded or unshielded,twisted or untwisted single pair wiring; and providing dual short circuit isolating output loops • Remote annunciator module support with remote unit interface(RUI) communications port,either Class B or Class A operation Figure 1:2-Bay 4010E5 Fire Alarm Control •48 LED panel mount annunciation provides 40 red and 8 yellow Unit with 2x40 Monochrome LCD Display pluggable LEDs(select models),optional LED kits are available for custom LED configurations 4010ES Agency Listing*: Optional Main System Supply 2 and door mounted modules,and • UL 864-Control Units,System(UOJZ);Control Unit Accessories, other options include the following: System,Fire Alarm(UOXX);Control Units,Releasing Device Service • City Connect Module (SYZV);Smoke Control System Equipment(UUKL) •Alarm relay module • UL 1076-Proprietary Alarm Units(APOU) • Battery brackets for seismic area protection • UL 1730-Smoke Detector Monitors and Accessories(UULH) • UL 2017-Emergency Alarm System Control Units,CO detection(FSZI); Optional block space modules include the following: Process Equipment Management(QVA() • Fire alarm network interface card(NIC)for ES Net or 4120 network • ULC-5527-Control Units,System,Fire Alarm(UOJZ7);Control Unit • network communications,supportsAccessories,System,Fire Alarm(UOXX7);Control Units,Releasing Peer-to-peer either Class B or Device Service(SYZV7) Class X operation • ULC-S559-Central Station Fire Alarm System Units(DAYR7) • Ethernet connectivity options include ES Net NIC,Building Network • ULC/ORD-C1076-Proprietary Burglar-Alarm System Units(APOU7) Interface card(BNIC),and BACpac Ethernet portal • Dual RS-232 Module for printer or third party interface • ULC/ORD-C100-Smoke Control System Equipment,(UUKL7) •VESDA Air Aspiration High Level Interface • Serial DACT • 8-Point Zone/Relay Module •4-Point Auxiliary Relay Module with Feedback • 8 Zone IDC Modules Class A or Class B • Four point Auxiliary Relay module • Modem or TCP/IP Physical Bridge Network Modules,Class B or Class X •Additional IDNet addressable channels • Connected Services Gateway *This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7165-0026:0369 for allowable values and/or conditions concerning material presented in th s document.It is subject to re-examination,revision,and possible cancellation,NYC Fire Dept COA#6095.Additional listings may be applicable,contact your local Simplex product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. S4010-0004 Rev.26 06/2022 t3Simplex • 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Introduction 4010ES series fire detection and control units provide leading edge installation,operator,and service features for customer applications in the mid- range addressable fire alarm systems market.An onboard Ethernet port provides fast external system communications to expedite installation and service activity.Dedicated compact flash memory archiving provides secure on-site system information storage of electronic job configuration files. Modular design:A variety of functional modules are available to meet specific system requirements.With these selections,you can configure control units for either stand-alone or networked fire control operation. InfoAlarm Command Center options provide convenient expanded display content.Refer to data sheet InfoAlarm Command anterfor the 4010ES Fire Alarm Control Unit S4010-0009 for more information. Compatible with the following Simplex remotely located modules: •4098-9757 QuickConnect2 and legacy 4098-9757 QuickConnect TrueAlarm smoke sensors •4003EC Small Voice Control Units •4009 IDNet NAC Extenders(4009A) •4081 Series,110 Ah Battery Chargers •4100-7400 Series Graphic Annunciators • 4190 Series Fiber Modems and Physical Bridges •4608-9102 Remote LCD Annunciator and 4100-9400 Series Remote ES Touch Screen Displays,and 4100-9400 Series Remote InfoAlarm Command Centers,and 4602 Series Status Command Units(SCU)and Remote Command Units(RCU)Annunciators Mechanical description • Mounting box provides convenient stud markers for drywall thickness and nail-hole knockouts for quicker mounting • Includes smooth box surfaces for precise local cutting of conduit entrance holes •The hinged user interface panel easily opens for internal access • NACs mount directly on power supply assemblies providing minimized wiring loss,compact size,and readily accessible terminations • Modules are power-limited except where noted,such as relay modules • Doors include tempered glass inserts;boxes and doors are available in platinum or red • Box and door or retainer assemblies are included with basic control unit assemblies • Cabinet assembly is rated NEMA 1 and IP 30 • Cabinet assembly design is seismic tested and is certified to IBC and CBC standards and to ASCE 7 categories A through F;requires battery brackets as detailed on data sheet Battery Brackets for Seismic Activity Applications S2081-0019 Control unit hardware The Master Controller and Main System Supply 2 Mount the Master Controller and Main System Supply 2 in the upper section of the 4010E5 cabinet.See Figure 10 for more information. 4010ES Block Space Option Cards Mount the 4010ES Block Space Option Cards to the left of the 4010ES Main System Supply 2.In two-bay cabinets,mount the block space option cards below the 4010ES ESS. Other 4010ES options Mount the 4010ES City Connect module or the optional Alarm Relay module directly to the Main System Supply 2.These options are mutually exclusive. - - - — The battery compartment located in the bottom of the 4010ES cabinet accepts two batteries without interfering with expansion module space. Software feature summary •TrueAlarm individual analog sensing with front panel information and selection access • Dirty TrueAlarm sensor maintenance alerts,service and status reports including almost dirty •TrueAlarm magnet test indication appears as a distinct test abnormal message on display when in test mode •TrueAlarm sensor peak value performance report • • Install Mode allows grouping of multiple troubles for uninstalled modules and devices into a single trouble condition • Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring • Recurring Trouble Filtering allows the control unit to recognize,process,and log recurring intermittent troubles such as external wiring ground faults, but only sends a single outbound system trouble to avoid nuisance communications • WALKTEST silent or audible system test performs an automatic self-resetting test cycle Compatible peripheral devices The 4010ES is compatible with an extensive list of remote peripheral devices including printers and both conventional and addressable devices including TrueAlarm analog sensors. Page 2 S4010-0004 Rev.26 06/2022 • OSimplex • 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Addressable device control The 4010ES provides standard addressable device communications for IDNet compatible devices.Using a two-wire communications circuit,individual devices such as manual fire alarm stations,TrueAlarm sensors,conventional IDC zones,and sprinkler waterflow switches interface to the addressable controller to communicate their identity and status. Addressability allows the location and condition of the connected device to display on the operator interface LCD and on remote system annunciators. Additionally,control circuits such as fans or dampers may be individually controlled and monitored with addressable devices. Addressable operation Each addressable device on the communication channel is continuously interrogated for status condition such as:normal,off-normal,alarm, supervisory,or trouble.Both Class B and Class A pathway operation is available.Sophisticated poll and response communication techniques ensure supervision integrity and allow you to T-tap the circuit for Class B operation.Devices with LEDs pulse the LED to indicate receipt of a communications poll,and you can change them to steady from the control unit. IDNet addressable channel capacity The Main System Supply 2 provides an electrically isolated IDNet2 signaling line circuit(SLC)that supports up to 250 addressable monitor and control points intermixed on the same pair of wires.Additional 250 address IDNet 2+2 Modules with four short circuit isolating output loops are available. IDNet 2+2 Module SLCs are isolated from other system reference voltages to reduce common mode noise interaction with adjacent system wiring. Table 1:IDNet 2 and IDNet 2+2 SLC wiring specifications Specification Rating Maximum distance from control unit for each 0 to 125 4000 ft(1219 m);50 ohms device load 126 to 250 2500 ft(762 m) 35 ohms Total wire length allowed with T-taps for Class B wiring Up to 12,500 ft(3.8 km);0.60 pF Maximum capacitance between IDNet channels - 1 pF Wire type and connections Shielded or unshielded,twisted or untwisted wire.See note. !Connections Terminals for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2) Installation instructions 579-989 Compatibility includes:IDNet communicating devices and TrueAlarm sensors including QuickConnect2 sensors.See data sheet S4090-001 1 for additional reference. Note:Some applications may require shielded wiring.Review your system with your local Simplex product supplier. TrueAlarm system operation Addressable device communications include operation of TrueAlarm smoke and temperature sensors.Smoke sensors transmit an output value based on their smoke chamber condition and the CPU maintains a current value,peak value,and an average value for each sensor. To determine status,compare the current sensor value to its average value.Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. Programmable sensitivity You can select the programmable sensitivity of each sensor at the control unit for different levels of smoke obscuration,shown directly in percent,or for specific heat detection levels.To evaluate whether to revise the sensitivity,read the peak value,which is stored in memory,and compare the value to the alarm threshold directly in percent. CO sensor bases CO sensor bases combine an electrolytic CO sensing module with a TrueAlarm analog sensor to provide a single multiple sensing assembly using one system address.You can enable or disable the CO sensor for use inLED or Switch modes and custom control,and you can make the CO sensor public for communication across a fire alarm network.Refer to data sheet TrueAlarm CO Sensor Bases for Smoke,Heat,and Photo/Heat Sensors using IDNet Communications 54098-0052 for details. TrueAlarm heat sensors You can select TrueAlarm heat sensors for fixed temperature detection,with or without rate-of-rise detection.Utility temperature sensing is also available,typically to provide freeze warnings or alert to HVAC system problems.Readings are selectable as either Fahrenheit or Celsius. TrueSense early fire detection The Multi-sensor 4098-9754 provides photoelectric and heat sensor data using a single 4010ES IDNet address.The control unit evaluates smoke activity,heat activity,and their combination,to provide TrueSense early detection.For more details on this operation,refer to data sheet TrueAlarm Multi-Sensor Model A4098-9754 Providing TrueSense Early Fire Detection(S4098-0024). Page 3 S4010-0004 Rev. 26 06/2022 f3 Simplex • 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Diagnostics and default device type Sensor status TrueAlarm operation allows the control unit to automatically indicate when a sensor is almost dirty,dirty,and excessively dirty.The NFPA 72 requirement for a test of the sensitivity range of the sensors is fulfilled by the ability of TrueAlarm operation to maintain the sensitivity level of each sensor.CO Sensors track their 10 year active life status providing indicators to assist with service planning.Indicators occur at one year,six months, and when end of life is reached. Modular TrueAlarm sensors Modular TrueAlarm sensors use the same base and either smoke or heat sensor types.You can easily interchange the sensors to meet specific location requirements.This allows intentional sensor substitution during building construction when conditions are temporarily dusty.Instead of covering smoke sensors and causing them to be disabled,you can install heat sensors without reprogramming the control unit.The control unit will indicate an incorrect sensor type,but the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. Master Controller (CPU) • The 4010ES Master Controller includes dedicated compact flash Mass Storage memory for on-site system information storage and convenient Ethernet service port access • For quick and easy download of site-specific programming and firmware enhancements,the Ethernet port is conveniently accessed from the front panel.You can make firmware enhancements through software downloads to the onboard flash memory. • Every downloaded job is automatically stored to compact flash without overwriting earlier versions providing a means for recovering previous configurations • Downtime is reduced because the system stays running during download •You can upload and download modifications for greater service flexibility •You can store job specific files in the control unit such as test and inspection reports,record drawings,specifications,and more using mass storage. • RUI communications port supports either Class B or Class A operation for remote annunciation equipment Basic control unit description 401 DES control units include the following features: •An Operator Interface,Master Controller with Compact Flash,IDNet addressable device SLCs with short circuit isolating loops configurable for Class B or Class A operation • 8 A power supply with up to 2 A of auxiliary power,110 Ah(UL)or 50 Ah(ULC)battery charger(33 Ah max in one bay cabinet,50 Ah max with 4100-0650 battery shelf in two bay control cabinet);four Class A or Class B NACs rated at 3 A each for Special Application Appliances,selectable for synchronized strobe,or SmartSync horn or strobe operation over two wires;and 2 A for regulated 24 DC operation;one programmable auxiliary relay rated for 2 A at 32 VDC • One RUI Class B or Class A communications port for remote annunciation devices,cabinet and door • Support for up to 20 internal and external card addresses.Other standard options may be provided depending on model;see and for additional details on specific models. 8-point zone/relay module details: • Select as IDC or Relay.Configure up to eight Class B IDCs,or up to four Class A IDCs;or up to eight Relay outputs rated 2 A resistive at 30 VDC(N.O. or N.C.);or a combinations of IDCs and Relays;each zone is separately configurable as an IDC or Relay output. • IDC Support.Each IDC supports up to 30,2-wire devices.Zone relay modules may be powered directly from the control unit power supply or through the optional 25 VDC regulator module where required for 2-wire detector compatibility.Refer to 2-Wire Detector Compatibility Chart(579-8321 for additional details. •You can select the following IDC EOL resistor values as:3.3 kohms,2 kohms,2.2 kohms,3.4 kohms,3.9 kohms,4.7 kohms,5.1 kohms,5.6 kohms, 6,34/6.8 kohms,and 3.6 kohms+1.1 kohms.Refer to Zone/Relay Module installation Instructions(579-1236)for more details. Main System Supply 2 The Main System Supply 2 provides the power source and the input or output connections for the basic 4010ES control unit.The main features are listed in Basic control unit description. Page 4 S4010-0004 Rev.26 06/2022 S Simpl©c 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories Display properties • 8 inch(203 mm)diagonal,800 x 600 resolution color touch screen display capable of annunciating up to 8 active events without scrolling • Bright white LED backlighting provides efficient and long lasting illumination.The backlight is dim in a quiescent state and automatically switches to full power on touch or on event activity in system. Description ES Touch Screen Displays for 4010ES fire alarm systems provide a large display with extended information content,dual language support including UTF-8 character languages,and an intuitive control key interface with the following features: • Each 4010ES control panel supports up to 8 ES Touch Screen Displays,one main and seven remote.It can enable one ES Touch Screen Display to take-control and to designate access levels for interfaces not in-control.You can assign programmable LEDs to,in-control status indications. • Menu-driven format conveniently prompts operators for the next action required • Direct point callup displays individual points alphabetically and then homes in on the logical choice as more point information is entered • Event categories are color coded for quick visual representation;Red for Alarm and Priority 2 Events;Yellow for Supervisory and Trouble events • Date formats are either MM/DD/YY or DD/MM/YY •Time formats are either 24 hour or 12 hour with AM/PM • System Normal screen supports a color background(watermark)for company name,company logo,or other desired display content Page 6 S4010-0004 Rev.26 06/2022