Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (2)
Technical Specifications (continued) Overview CONFIGURATION INTERFACE The AES Corporation model 7706-ULF was engineered in close collaboration with Keypad with function,number and navigation keys Potter Electric Signal Co., designed specifically for small to mid-size fire protection applications. The 7706-ULF is a single-box integrated solution, bringing together ALARM SYSTEM PROGRAMMING AES-IntelliNet® patented alarm communications technology and Potter's proven INTERFACE Ethernet using programming software Fire Alarm Control Panel (FACP)for life safety. SUBSCRIBER PROGRAMMING The AES 7706-ULF Integrated Fire Monitoring System is a compact, simple panel INTERFACE designed to monitor and communicate the alarm status to a Central Monitoring Control Panel LCD and keypad Station. The 7706-ULF system is a listed and approved microprocessor-based fire UL STANDARDS monitoring panel and complies with UL-864 requirements as well as NFPA-70 and Meets UL-864 9th Edition-Standard NFPA-72 National Fire Alarm and Signaling Code. The panel features 6 Inputs and for Control Units and Accessories for Fire Alarm systems one 24 VDC 0.5A Notification Appliance Circuit(NAC)with strobe synchronization. The 2.0A Power Supply provides ample power to meet any jurisdiction's requirements, OPERATING TEMPERATURE RANGE 0°to 49°C(32°to 120°F) also has capacity to charge up to (2) 18AH batteries. In addition, the panel includes the Potter Signal P-Link for connection to a remote annunciator. STORAGE TEMPERATURE RANGE -10°to 60°C(14°to 140°F) The Panel Interface Card,jointly developed by AES and Potter, provides a high-speed RELATIVE HUMIDITY RANGE bi-directional communications interface between the fire control panel and the 0 to 93%RHC, Non Condensing AES 7788E subscriber.This allows alarm and status messages generated by the panel to be sent directly to the subscriber for transmission on the AES private wireless About AEs Corporation network. It also allows the panel to supervise the subscriber status to annunciate local AES Corporation is the leading manufacturer of code compliant trouble if the subscriber is not functioning correctly. wireless alarm communication Alarm signals, supervisory and trouble messages are transmitted through the products and solutions serving commercial security markets and AES 7788F Fire subscriber built into the panel enclosure.The panel zone input government agencies worldwide. configuration is done with the Potter Signal panel configuration software over the AES-fnte1iNet®patented TCP/IP network access port. The 7706-ULF keypad interface provides access to the technology will never sunset AES subscriber for configuration and status information. compared to obsoleting technologies such as cellular The AES 7706-ULF provides the Central Monitoring Station capability to quickly and traditional phone lines.AES detect any alarm condition. This is a complete departure from the use of traditional private mesh radio networks are phone lines, providing a high speed link between the alarm panel and the AES Smart owner operated and controlled, providing infinite salability and Subscriber. This link is always active and always supervised on both sides.The superior reliability with the fastest 7706-ULF with the built-in AES 7788F Smart Subscriber provides end-to-end agility transmission speed available. Over and a fault tolerant system. a half million AES Smart Subscribers are installed worldwide.AES is When it comes to preventing loss of life or property, network owners and operators as the clear choice for life safety and well as first responders rely on AES-IntelliNet®global alarm communications technology. security, protecting people and property for over 40 years. How to Order 7706-ULF / !O•' JLr integrated Lire Monitoring System ®PO1TFerz m C7 GSA CSAA � 1 Net( n The Symbol of ProreGMY NFPA - .. (•+ _( LISTED For more information, go to www.aes-corp.com Call or contact us at sales@aes-corp.com Copyright 2015 AES Corporation I AES-InrelliNetOO is a registered trademark of AES Corporation ,,,,!, ,, ER//,; %,,soirc PS-12100H 12 Volt 10.5 AH 4- Rechargeable Sealed Lead Acid Battery We' Features • Absorbent Glass Mat (AGM) technology for superior performance -�°. -, • Valve regulated, spill proof construction allows safe Ppll/ER ror/t' 1 operation in any position MODEL ,SA p'0°" • Power/volume ratio yielding unrivaled energy density • Rugged impact resistant ABS case and cover (UL94-HB) • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and t , C.A.B. certified • U.L. recognized under file number MH 20845 Ai la Terminals (mm) Performance Specifications Nominal Voltage 12 volts(6 cells) F--3.4-1 Nominal Capacity • F2-Quick disconnect El116.35 20-hr. (525mA to 10.50 volts) 10.50 AH tabs,0.250"x 0.032" Mate with AMP. INC 10-hr. (1.00A to 10.50 volts) 10.00 AH FASTON "250"series I-7.95-I 5-hr. (1.87A to 10.20 volts) 9.35 AH I ii r' = 0.8 1-hr. (6.82A to 9.00 volts) 6.82 AH 15-min. (17.2A to 9.00 volts) 4.30 AH Physical Dimensions: in(mm) Approximate Weight 7.23 lbs. (3.28 kg) Energy Density(20-hr. rate) 1.88 W-h/in3(114.92 W-h/i) Cl T Specific Energy(20-hr. rate) 17.43 W-h/Ib(38.42 W-h/kg) W Internal Resistance(approx.) 12 milliohms Max Discharge Current(7 Min.) 31.5 amperes Max Short-Duration Discharge Current(10 Sec.) 105.0 amperes , 1-- I Shelf Life(%of nominal capacity at 68°F(20°C)) milmoili 1 Month �MooIl'''' HT 3 Months 90% H 6 Months 80% r tr 6Operating Temperature Range f L 1 + Charge -4°F(-20°C)to 122°F(50°C) Discharge -40°F(-40°C)to 140°F(60°C) L•5.94(151) W:2.56(65) H:4.40(112) HT.4.67(118) Case ABS Plastic(UL 94-HB) Tolerances are+/ 0.04 in.(+/-lmm)and+/-0.08 in.(+/-2mm)for Power-Sonic Chargers PSC-122000A, 122000A-C height dimensions.All data subject to change without notice. To ensure safe and efficient operation always refer to the latest edition of our Technical Manual,as published on our website. All data sub ect to chame without notice. www.power-sonic.com - ' I, %,„ PS-12100H 12 Volt 10.5 AH , ,,,,N„A,,,,,11a,,,,,,,,,,,,,,1/14i,NI/50N/C Shelf Life &Storage Discharge Characteristics 100 14.0 III 1 1 III a l a 1 �n ass Ambient Temperature 20°C(68 F noceese0 100%of capacity 13.0 y is required. - ce a 80 E. 5°C Charging before 12.0 -- C _ use e arity.necessary m - O (41°F) whelp recover m III +r full rapacity. --1 .aa 80 > 11.0 \1 _ m to restore full o 0.53 40°C 30°C 20°C capacity.Do Rot .E 10.0 1.05 - - 'u 40 (104°F)-(86°F)_(68°F) let batte�sreach E 2.1 o. T I misstate Im 5.25 0 9.0 Final 0 0 2 4 6 8 10 12 14 16 18 20 Voltage 10.5 Standing Period (Months) 8.0 I I Y1 1.2 2.4 6 12 24 36 481 2 4 6 810 20 4 0 Discharge Time vs. Discharge Current 1-.- - min ►1- h '1 Discharge Time 20 15 \ Life Characteristics in Stand-By Use 10 .0 \ Ambient Temperature 20'C(68'F) chi 5 Final ' 3e 100 I 1 1 I Voltage �, 2 10.5V \\ 0 80 COa 10.2V \ a 60 u f 1 \ 0 Float Charging Voltage m c 40 2.25-2.30 V/Cell c 9.8V \ 20 0 30 \ e I K 0 9.OV \ 0 1 2 3 4 I 10 \ 40°C(104°F) Years 20°C (68°F) 0°C (32°F) 5 6.1I 1 Life Characteristics in Cyclic Use 0.53 1.05 2.1 5.25 10.5 21 120 Discharge Current(A) 100 - - ill. Charging 2, 80 - Cycle Applications:Limit initial current to 3.15A.Charge until battery voltage a (under charge)reaches 14.4 to 14.7 volts at 68°F(20°C).Hold at 14.4 to 14.7 m 60 Discharge Discharge Discharge volts until current drops to under 105mA.Battery is fully charged under these Depth 100% Depth 50'/n Depth i 30% C conditions,and charger should be disconnected or switched to"float"voltage. 0 40 tcr co 1.Discharge Current 0.2C(Final Voltage 1.7V/Cell) "Float"or"Stand-By"Service:Hold battery across constant voltage source of o 20 2.Charge Current:0.1C I 1 1 13.5 to 13.8 volts continuously.When held at this voltage,the battery will seek its CZ 3.Ambient Temperature:20°C to 25°C(66°F to 77°F) own current level and maintain itself in a fully charged condition. 0 0 200 400 600 800 1000 1200 Nob:Due to the self-discharge characteristics of this type of battery,it is Number of Cycles imperative that they be charged within 6 months of storage,otherwise permanent loss of capacity might occur as a result of sulfation. Chargers Further Information Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonlc.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for"CSeries downloads,such as product catalogs,material safety data sheets(MSDS),ISO Switch Mode Chargers"and"Transformer Type A and F Series".Please contact our certification,etc.. Technical department for advice if you have difficulty in locating suitable models. Contact Information www.power-sonic.com DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES Tel:+1-619-661-2020 Tel:+1-619-661-2030 Tel:+1-619-661-2020 Tel:+1-650-364-5001 Fax:+1-619-661-3650 Fax:+1-619-661-3648 Fax:+1-619-661-3648 Fax:+1-650-366-3662 national-sales@power-sonic.00m customer-service@powersonic.com support®power-sonic.com intemationalsalesOpoMer4oniccom CORPORATE OFFICE • 7550 Panasonic Way • San Diego,CA 92154 • USA•Tel:+1-619-661-2020 • Fax:+1-619-661-3650 0112 1M 02012.Power-Sonic Corparetfon.at rights reserved.All trademarks are the property o1 their respective owners. *-11 SYSTEM \,_, 1 SENSOR® ( {t Photoelectric 4g}?P Smoke Detectors ' .1064 System Sensor i3-series smoke detectors represent significant advancement in conventional detection. 3 The i3 family is founded on three principles:installation ease,intelligence,and instant inspection. Features Installation ease.The 13 line redefines installation ease with its •Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide •Large wire entry port ample room for neatly routing the wiring inside the base.The base -In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as •Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,13 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock'action. -Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features •Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and •Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a remote LED- •Drift compensation and smoothing algorithms indicated maintenance signal when connected to the 2W-MOD2 •Simplified sensitivity measurement loop test/maintenance module or a panel equipped with the i3 •Wide-angle,dual-color LED indication protocol.The SENS-RDR,a wireless device,displays the sensitivityof P detectors in terms of percent-per-foot obscuration. •Loop testing via EZ Walk feature •Built-in test switch Instant Inspection.The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition:normal standby,out-of-sensitivity,alarm,or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol,the EZ Walk loop test feature is available on 2-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings ® ,T ® avvArneo 1) MEA MSFM �� LISTED Ili approved approved " 39"1 011446 7272-1653:152 290-01-E 2093 3130932 C])Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor P Series model number .listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31h-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 3096 peak to peak of applied voltage Standby Current 2-wire:50 pA maximum average;4-wire:50 pA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24V Peak Standby Current 2-wire:100 pA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100°F(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes Power-Up Sequence for LED Indication LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal Wiring Alarm Current 2W-B No 2-wire 130 mA max.limited by control panel 2WT-B Yes 2-wire 130 mA max.limited by control panel 4W-B No 4-wire 20mA@12V,23mA@24V 4WT-B Yes 4-wire 20mA@12V,23mA@24V Accessories 2W-MOD2 2-wire loop test/maintenance module RT Removal/replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter SYSTEM 02009 System Sensor �/�� 38250hI0AVenue•St.Charles,IL60174 Rod=spedfscauonssubjecttocnangewirMutnoucevs¢ryscemsensorcomfor SE!YSOR' Phone:800-SENSOR2-Fax:630-377-6495 cunML product'nfouraaon.InClWn9the latest version ofthadata shy. A05-0319-007•6V09•42169 P POT'I'ER PULL STATION SERIES DIE-CAST METAL The Symbol of Protection MANUAL PULL STATIONS • UL and cUL Listed,FM Approved,CSFM Listed,MEA FIRE ALARM FIRE ti ALARM Approved,ADA Compliant • Single or Dual Action •1 11 r FIRE PULL DOWN Terminal connectors ALARM I • 10 Amp Snap Action Switch • Gold plated SPST contacts LIFT • Optional auxiliary contacts to" I• & 11111c �" • Mounts on standard single gangbox POLL • Surface backboxes available t; •• High-gloss red enamel finish • Glass breakrod `©°' 4; <> ® • Made in the U.S.A. Description Engineering Specifications The Potter Pull Station Series offers a complete line of die-cast pull The contractor shall furnish and install the Potter series of pull stations for a variety of applications focusing mainly on fire alarm stations as indicated.The pull station shall be die cast construction systems.The pull stations are available in single or dual action with a"T"type pull handle that is ADA compliant. Single action pull models.All of the pull stations have a 10-amp snap action switch and stations shall be a P32-1 T.Dual action pull stations shall be the Potter a dedicated triminal block for the ease of wire connections.All of P32-I T-LP.Any manual pull station installed in an outdoor or wet the metal is completely coated to inhibit corrosion and provide for a location shall be a RMS-1T-WP weather proof unit.The contact shall uniform and quality finish. be a single pole,single throw switch rated at I amp 30V DC/125V The standard models have a hex key reset,however a key reset is also AC.The device shall have a terminal block for ease of wiring.Once activated,the pull station shall be reset by opening the front cover.available.The models are available with shallow and deep surface mount back boxes and as a weatherproof version. Opening of the cover in a normal state shall initiate an alarm. Operation Specifications The Potter single action series of pull stations operate by pulling Switch Rating: 1 Amp @ 30 VDC the white operating handle straight down and the handle will lock I Amp @ 125 VAC into place.The dual action stations require the lifting of the front Pull Station Dimensions: 4-3/4"H x 3-1/4"W x 7/8"D Color:Red with raised white letters,white pull bar with raised red letters cover and then pulling the white operating handle straight down.The stations are reset by opening the front and placing the handle in the normal position. For special application manual stations see bulletin#8910014. For explosion proof manual stations see bulletin#8880014. Ordering Information Type Model Number Stock Number Contact Type \ P32-IT 1000447 SPST y RMS-2T 1000477 DPST Single Action RMS-6T 1000478 DPDT RMS-I T-KL 1000451 SPST RMS-1 T-KO 1000450 SPST,key operated,no pull ' Weather Proof RMS-1T-WP 1000401 Dual Action P32-1T-LP 1000476 SPST Weather Proof Dual Action RMS-1T-WP-LP 1000403 Accessories Notes Dual Action RMS-LP 1000480 Converts single action to dual action Back Box P32-BB 1000444 Surface mount back box Back Box P32-DBB 1000445 Deep surface mount back box Glass Rods RMS-GB 1000470 Replacement glass rods(10 per pkg) Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211• Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8900097-REV K PAGE 1 OF I 5/10 STORE FIRE-PANEL, MAINTENANCE & AS BUILT DOCUMENTS THE DOCUMENT BOX It's often important, or even required that you store documents near fire-panels or other systems you've installed. I , ,., The BW-DocBox Instruction. is the easy answer! 1 installation.and 1fainlcnanie ilanual al, BW-DocBox AS 9UILT PERMITS BW-DocBox BW-DocBox2 15"W x 13" H x 4" D 11"W x 15"H x 4"D fin ALARMmews includes: Smaller and more basic • THREE labels: model without the door TEST ANDMAiNTENANCE "Fire Alarm Documents" bracket for CDs and key DOCUMENTS "As Built Permits" sets. However, it does "Test and Maintenance Documents" have the three labels, , I • An adjustable bungeeallows you to adjustable bungee and Four boxes in one! T fit various sizes of binders, a lock with two keys. 1 ,i. blankhedoor, or onecan ofbe theleft three documents, smoke-cans, etc. labels may be used. _. • A door bracket holds two CDs, three sets of keys and more documents • A cam lock with two keys ki Don't see the box you want? Call us or visit our website! Customization and/or silk-screening of logos is available for quantities of 25 or more. (requires lead time) Bw-DocBox2 411. isolirghTh EMBE• Made in the . 11 U.S.A. I r lki, ! a a , a .. . - - - - •-