Report • fp 2O VOA/ O OFFICE COPY RECEIVED APR 2 6 2[23 CITY OF TIGARD BUILDING DIVISION Safeway Tigard #03542 14300 SW Barrows Road, Tigard, Oregon 97223 Fire Protection Data BASIC FIRE PROTECTION, INC. 8135 NE MLK JR BLVD. PORTLAND, OREGON 97211 Table of Contents Fire Protection System I. Fire Protection Pipe and Fittings: a) Bull Moose:Black Steel Pipe Sch.40 b) Anvil:Cast Iron Fittings c) Victaulic:Outlet-T Style 722 2. Hangers: a) Sammys:Xpress SXP-20 b) Tolco:Fig.65 Beam Clamp c) Tolco:Fig.69 Retaining Strap d) Tolco:Fig.200 Ring Hanger 3. Fire Sprinklers: a) Reliable:F1FR RA1414 5.6k 155°F ''A"Chrome b) Reliable:Fl RA1314 5.6k 155°F 4"Chrome c) Tyco: TY5255 DS-2 11.2k 286°F 1"Chrome w/Extended Canopy d) FPPI: 2 Piece Sprinkler Escutcheon(Canopy)White e) FPPI: Oversize Escutcheon Ring White SCHEDULE 10 D40 ). .,... . .. ...: , i 'e, likkle. /a3L)%°° . ' . x, 1, 14 b ., Always ready to protect your most valuable assets. As the leading supplier of steel sprinkler pipe,we understand that there are no second chances in fire suppression.You need products of enduring quality and exceptional strength—plus reliable service.You need Bull Moose. Bull Moose Fire Sprinkler Pipe Product Information Nominal Pipo size(Inches) 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" 6" 8" NPS{In.) 1" 1.1/4" 1.1/2" 2" 2-1/2" 3" 4" 0.D.(in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 1.315 1.660 1.900 2.375 2.815 3.500 4.500 A ID.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 6357 8.249 0CT 1.049 1.380 1.610 2.067 2.469 3.068 4.026 NJ Empty Weight(Ib/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 LJJ 1.600 2.270 2.720 3.660 5.800 7.580 10.800 —1 Water Filled Weight(1b/FL) 1.820 2.518 3.053 4.223 5.893 7.957 11.795 23.038 40.086 J 2.055 2.918 3.602 5.114_ 7.875 10.783 16.316 CRC.R. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 IT, 1.00 1.00 1.00 1.00 1.00 1.00 1.00 NJ Pieces per Lift 91 51 61 37 30 19 19 10 7 _ W 70 51 44 30 30 19 19 2lengths ' 2,431 2,513 2,306 3,654 3,024 4,309 tri Lif[Weight(Ibs121' 2,695 2j19 2,677 2,051 2,224 1,732 2,242 1,951 2,490 2,470 �.. Lift Weight(Ins)24'lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 2,822 2,778 2,872 2,635 4,176 3A56 4,925 Lift Weight(Ins)2E lengths 3,208 2,760 3,187 2,442 2,548 2,062 2,670 2,940 2,894 2,992 2,745 4,350 3,601 5,130 SCHEDULE 10 0 40 ADVANTAGES: OTHER RENEFITS/SERVICE • UL listed (US&Canada)and FM approved • We have the most stocking locations in the industry, • ASTM A135 and A795 Type E.Grade A Certified for best delivery and availability • • Complies with NFPA-13, 13R and 14 Plain end or roll groove • Eddy Guard II"bacterial-resistant internal coating • Industry-leading hydraulic characteristics • Custom length options • CRR of 1.0 and greater • Hot dipped galvanization • All pipe NDT weld tested • Reddi-Pipe"red or black pipe eliminates field painting • Compatible for use in wet,dry,preaction and deluge sprinkler systems Exclusive maker of Reddi-Pipe® RED OR BLACK PAINTED PIPE. • The only maker with EPDs(to help earn LEED points). ERT�`FIED °�c us LISTED ® fM ,4ONFSA APPROVED NFPA .-_. 1�� ,� . ..x. - .• . 800.325.4467 sales( uIIMooselndustrieS corn , BULL. ]� oosa' • K � TUBE' :Al 4 fk» Anvil Cast Iron ' Manufactured in Columbia,PA USA,Anvil lik offers the most complete line of Cast Iron - and Malleable Iron Threaded Fittings in the industry.Our versatile range of fittings is — - designed to provide connection options for different applications and environments. 410 1 Cast Iron(Gray Iron)Threaded Fittings are a , -- = r. • i manufactured in accordance with ASME/ANSI 614.4 and are UL/ULC listed and FM approved. Malleable Iron Fittings are manufactured in accordance with ASME/ANSI B16.3 and ' Unions ASME/ANSI B16.39 and are available 11/ in Class 150,Class 250,and Class 300 UL/ULC listed and FM approved.In both classes,all .. t 11.• t Elbows and Tees 3/8"and larger are 100%air 1110 1 tested at a minimum of 100 psi(6.9 bar). c(DIES <> Cast Iron Flanged Fittings are manufactured LISTED APPROVED in accordance with ASME B16.1 and are available in both Class 125 and Class 250. Anvil Steel Pipe Nipples & Steel Pipe Couplings Anvil offers a variety of Steel Pipe Nipples and Steel Pipe Couplings for standard nipple packs ranging from one each (close to 6")and the fire protection industry. standard six packs which offer multiple counts of each.Cartons are packed with handles for easy carrying. Anvil's Steel Pipe Nipples are manufactured in accordance with ASTM/ ANSI A 733 welded and seamless carbon steel pipe nipples.Materials Steel Pipe Couplings are manufactured in accordance with ASTM include black and hot-dipped galvanized finishes.Anvil manufactures a specification A 865. Straight-tapped couplings range in size from Is" wide range of stock pipe nipples in '/e'diameter through 8"diameter NPS through 2"NPS,while 21"NPS and larger are taper tapped. close through 72"inch length in half-inch increments.We also offer SPF/RNVIL Cast Iron Threaded Fittings SPF Ductile Iron Threaded Fittings are UL/ ULC Listed and FM Approved for 500 psi service.These fittings provide a dependable threadedngef connectionan and are availableAllin a range of styles and specifications.All SPF A Ductile Iron Threaded Fittings dimension ir s conform to ANSI B16.3 Class 150 require- ments,and threads are NPT per ANSI/ASME B1.20.1. SPF Cast Iron Threaded Fittings are UL/ULC s Listed and FM Approved for 300 psi service. These fittings are available in a range of III is 'Illir styles and specifications.All SPF Cast Iron Threaded Fittings dimensions conform to ANSI B16.4 requirements,and threads are c 4L us Em NPT per ANSI/ASME 81.20.1. uslEn APPROVED WI' 111114116 , i,Zl))ANVIL www.anvilintl.com Fire Products 3 Victaulic® FireLockTM Outlet-T �ctaul�c" Style 922 10.52 • • • • 1.0 PRODUCT DESCRIPTION Available Sizes • 1 1/4— 2 1/2'/DN32 — DN65 • Threaded Outlet Sizes: 1/2"/DN15, 3/4"/DN20, and 17DN25 NOTE • IGS Grooved 1"/DN25 Outlets available for this product.See publication 10.54. Maximum Working Pressure • 300 psi/2068 kPa/21 Bar Application • Provides a convenient method of incorporating outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products Pipe Material • Carbon steel • Contact Victaulic for use on additional pipe types and wall thicknesses 2.0 CERTIFICATION/LISTINGS : ,• ® vas LPCB'' i"P MED NOTES • See Section 7.2 REFERENCE MATERIALS for additional certification information. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. •System No. Location Spec Section Paragraph •' Submitted By Date Approved Date • victaulic.com 10.52 3355 Rev H Updated 06/2018 0 2018 Victaulic Company.All rights reserved. ictauIic` victaulic.com • 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Orange enamel (North America, Latin America, Asia Pacific). ❑ Red enamel (Europe). ❑ Optional: Contact Victaulic with your requirements for other coatings. Gaskets: ❑ Grade "E" EPDM (Type A) EPDM (Violet color code)Applicable for wet and dry(oil-free air) sprinkler services only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at-40°F/-40°C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: ❑ Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial — hex nuts)and ASTM A563M Class 9 (metric— hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM 8633 Fe/Zn 5, finish Type III (imperial) or Type II (metric). • 10.52 3355 Rev H Updated 06/2018 ©2018 Victaulic Company.All rights reserved. victaulic.com � � rctauLc' • • victaulic.com 4.0 DIMENSIONS Style 922 Y Z V /"..� i011111 11 Style 922 Size Bolt/Nut Dimensions Weight Nominal Actual Approximate Run x Branch FPT2 Outside Diameter Qty. Size T3 V W Y Z (Each) inches inches inches inches inches inches inches inches lb DN mm mm mm mm mm ! mm mm kg 1'/4 -1/2 1.660 0.840 I 1.30 1.83 1.10 3.87 2.56 1 0N32 x DN15 42.4 x 21.3 2 1x 1 1 33 47 28 98 65 0.5 3/4 1.050 2 x l 1.28 1.83 1.10 3.87 2.56 1 DN20 26.9 33 47 28 98 65 0.5 1 1.315 '.i 2 x 1 1.52 2.18 1.10 3.87 2.56 1 DN25 _ 33.7 39 55 28 98 65 0.5 1 h 1/2 1.900 0.840 1.42 1.95 1.22 4.08 2.56 1 40 x DN15 48.3 x_ 21.3 2 x 1 36 50 31 104 65 0.5 3/4 1.050 2 '�x 1 1.40 1.95 1.22 4.08 2.56 1 DN20 26.9 36 50 31 104 65 0.5 1 1.315 2 x 1 1.64 2.30 1.22 4.08 2.56 1 DN25 33.7 42 58 31 104 65 0.6 2 1/2 ! 2.375 0.840 1.66 2.19 1.46 4.60 2.56 1 50 x DN15 60.3 x 21.3 2 x 1 42 56 37 117 65 0.6 3/4 1.050 2 x 1 1.64 . 2.19 1.46 4.60 2.56 1 DN20 26.9 42 56 37 117 65 0.6 1 1.315 2 x 1 1.88 2.54 1.46 4.60 2.56 2 DN25 33.7 48 65 37 117 65 0.7 21/3 Y 2.875 0.840 2 1.91 2.44 1.71 5.40 2.56 2 x DN15 73.0 x 21.3 xl'� 49 62 43 137 65 0.7 3/ 1.050 2 x 1 1.89 2.44 1.71 5.40 2.56 2 DN20 26.9 48 62 43 137 65 0.7 1 1.315 2 x 1 2.13 2.79 1.71 5.40 2.56 2 DN25 33.7 54 71 43 • 137 65 0.7 DN65 1/2 3.000 0.840 x 1.91 2.44 1.71 5.50 2.56 2 x x 2 1, DN15 76.1 21.3 49 62 43 140 65 0.7 3A 1.050 1.89 2.44 1.71 5.50 2.56 2 DN20 26.9 2 x 1 i 48 62 43 140 65 0.7 1 1.315 2.13 2.79 1.71 5.50 2.56 i 2 DN25 33.7 2 i x 1 54 71 43 i 140 65 0.8 2 Victaulic female threaded products are designed to accommodate standard NP I or BSPT(optional)male pipe threads only.Refer to the specific literature for these types of special male-threaded products for guidance and possible limitations for use.Failure to verify suitability in advance may result in assembly problems or leakage. 3 Center of run to engaged pipe end for NPT threads(dimensions are approximate). • • 10.52 3355 Rev H Updated 06/2018 c 2018 Victaulic Company.All rights reserved. victaulic.com . ' /ctaulic' • victaulic.com 5.0 PERFORMANCE Style 922 Equivalent Length of 1 inch Schedule 40 Steel Pipe(per UL 213,Section 16)(C=120)4 Run Size x Outlet Size Threaded Grooved5 inches feet feet DN meters meters 1 14 1 8.5 12.5 DN32 x DN25 2.6 3.8 1 1 1 8.5 12.5 DN40 DN25 1 2.6 3.8 2 1 8,5 12.5 DN50 x DN25 2.6 3.8 21/2 1 8.5 12.5 x DN25 2.6 3.8 1 8.5 12.5 DN65 x DN25 2.6 3.8 4 Hazen-Williams coefficient of friction is 120. 5 1'FireLock", Innovative Groove System(IGS)outlet 6.0 NOTIFICATIONS II • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. • Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Dimensions Minimum Hole Diameter/ Maximum Hole Diameter/ Hole Saw Size Hole Saw Size inches inches mm mm All Outlet Sizes -- 1 Pb 1 9. L�__—._ 30 32 10.52 3355 Rev H Updated 06/2018 ®2018 Victaulic Company.All rights reserved. victaulic.com A /ctaulic° • • • . victaulic.com 7.1 REFERENCE MATERIALS Size Services Pressures per Regulatory Approvals and Listings6 Nominal UL ULC FM Vd S LPCB CNBOP inches psi psi psi psi psi psi DN kPa _ kPa kPa kPa kPa kPa -- 1 1 x 1/2- --_---- 300 300 300 232 232 232 DN32 X DN15 2068 2068 j 2068 1600 1600 1600 1'/4 x'/4 300 300 300 232 232 232 DN32 X DN20 2068 2068 2068 1600 1600 1600 1 1/4 x 1 300 300 300 232 232 232 • DN32 X DN25 2068 2068 2068 1600 1600 1600 1' x 1/2 300 300 300 232 232 232 DN40 X DN15 2068 2068 2068 1600 1600 1600 • 1 12 x 1/4 300 300 300 232 232 232 DN40 X DN20 2068 2068 _2068 1600 1600 1600 1'/z x 1 300 300 300 232 232 232 DN40 X DN25 2068 2068 2068 1600 1600 1600 2 x1/2 300 300 300 232 232 232 DN50 X DN15 2068 2068 2068 1600 1600 1600 2 x34 300 300 300 232 232 232 DN50 X 20 2068 2068 2068 1600 1600 1600 2x 1 300 300 300 232 232 232 DN50 X DN25 2068 2068 2068 1600 1600 1600 21/2x'/z 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 21/2 x'/4 300 300 300 232 I 232 232 2068 2068 2068 1600 1600 1600 2 Yz x 1 300 300 300 232 232 232 2068 1 2068 2068 1600 1600 '. 1600 --�� _ _ 300 232 232 232 DN65 X DN15 ! 2068 1600 1600 1600 _ 300 232 232 232 — DN65 X DN20 2068 1600 1600 1600 — _ 300 232 232 232 i • DN65X DN25 2068 1600 1 1600 1600 1 c, Pressures listed in this chart are based upon standard wall pipe.Approved and Listed pressures may vary by pipe schedule. NOTE • Consult regulatory agency websites for details and the most recent regulatory information. 7.2 REFERENCE MATERIALS 05.01:Victaulic Seal Sc.cct On U,iiuc 79 01.Viol-atilt Terms and Connitinns of Sale 1-100: Installation Instructions 1-922:Installation Instructions FireLockna Outlet-T • , user Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to he installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on WeChat. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Viclaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United Slates and/or other countries. • • 10.52 3355 Rev H Updated 06/2018 0 2018 Victaulic Company.All rights reserved. victaulic.com " /ctaulic' SAMMY X-PRESS® Installs into Metal Deck, Purlin, or Tubular Steel 1 SAMMY X-PRESS® -Vertical Application Application < Product Features - i (The Sammy X-Press expands to provide •Less jobsite material needed. direct vertical attachment in: s (Xp) - light gauge steel deck or purlin •No retaining nut required. •Provides design flexibility. V:• •Installs in seconds with Sammy X-Press It®Tool, iltitT saving time&installation costs. •Assembledin the U.S.A. •Use in applications where access to the back of View our the installed fastener is prohibited.ie.metal roof installation videos! deck,tubular steel,or vapor barrier fabric. CI YuuTube Approvals Rod Part Model Description Ultimate UL Test UL Min FM Test FM Min Max Box Case Application Size Number Pullout(Ibs) Load(Ibsl Thick Load(Ibs) Thick Thick Qty Qty VERTICAL MOUNT al• MT 8181922 XP 200 Sammy X-Pr ss 200 1146(22 ga) 185(Luminaire) 027" .125" 25 125 Metal Deck 850(2h°Pipe) .027' 940(2"Pipe) .029" Sammy 165(Luminare) .027° .g 316" 8150922 XP 20 X-Press 20 1146(22 gal 21550(Luminaire) .gam^ 1475(4'Plpe) .104' 125" 25 125 Metal Deck 283(Conduit&Cable) .029° 1500(4"Pipe) 060' 318' 8153922 XP 35 X Press 35 1783(16 ga) 250(Lumi Aire) .D056' 1475(la•Pipe) .0104" 125" 25 125 Park, 416(Conduit&Cable) .059" Pre-Pour Sbuctural Concrete@ 3000 psi Metal Deck Sammy , (Pre-Pour) — .Q. 3l8' 8150922 XP 20 X-Press 2D 1146(22 ga) 850(2X Pipe) 25 125 Metal Deck Post-Pour Range II LWCS 35 PCF(Ibslft) (Pout-Pour) Pre-Pour Structural Concrete@ 3000 pal PoabPour Range II LWCC 35 PCF)lbel ft•) L. a SAMMYX-PRESS SIDEWINDER'' - Horizontal Application Application Product Features •The Sammy X-Press Sidewinder expands to •Less jobsite material needed, t- ,. provide horizontal attachment in: - _: _ -16 ga-3/16"steel-purlin,tubular steel. •No retaining nut required. •Installs in seconds with Sammy X-Press It'Tod, •Provides design flexibility. saving time&installation costs. •Assembled in U.S.A.of •Use in applications where access to the back of Canadian Steel the installed fastener is prohibited;ie.metal roof View our deck,tubular steel,or vapor barrier fabric. installation videos! OYoluT& Approvals Rod Part Model Description Ultimate UL Test UL Min FM Test Max Box Case Application Size Number Shear(Ibs) Load(lbs) Thick Load(Ibs) Thick Qty Qty HORIZONTAL MOUNT v i '`. Sidewinder 1250(3h'Pipe) Metal Deck/ CP.- 318' 8293957 SWXP35 X-Press 35 1798(16ga) 8D(Luminaire) .059" .125" 25 125 Purlin "py�,,,,, 416(Conduit&Cable) 1.5 For the most up to date information,visit www.itwbuildex.com 8 Beam Clamps TOLCO Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4"(19.omml Throat Opening Size Range: Fig. 65 - 1/2"-13 rod sizes,and a/a"-11 rod sizes C©111 Fig. 65XT - 3/e'-16 rod size(see below) LIMO Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does e not exceed'/4 (19.0mm). a Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled41114114�� c lip allows hanging from top flange where clearance is limited.) May be installed with ' IA l00 set screw in up or down position. Offset design permits unlimited rod adjustment by �iy allowing the rod to be threaded completely through the clamp. Open design permits F 44_ inspection of thread engagement. dL A Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL). %fie Exceeds requirements of the National Fire Protection Association(NFPA), pamphlet 13, 3/s"-16 rod will support'/2"(15mm)thru 4"(100mm) pipe 1/2"-13 rod will support thru 8" (200mm)pipe Set Screw and Locknut Included Finish: Plain or Electro-Galvanized. Contact customer service for alternative finishes and materials. Order By: Figure number and finish { c. Fig. 65 Patent#4,570,885 3 �� . ) Q a Part Rod Size B C D E e, No. A in. (mm) in. (mm) in. (mm) in. (mm) A 65-1/2 '/2"-13 172' (38.1) 3/4' (19.0) 1" (25.4) yh3" (14.3) 65-1/4 5/3-11 11/2" (38.1) 3/4" (19.0) 1" 125.4) 3/4' 114.3) /Part F Approx.Wt./100 - 4 No. in. (mm) Lbs. (kg) ! + r2` 65-1/2 1'/4' (31.7) 55 (24.9) 65-5/t 1'/4' (31.7) 55 (24.9) TOLCO Fig. 65XT- Reversible Steel C-Type Beam Clamp 3/4" (19.omm)Throat Opening Feature: Extruded holes allows for more thread 1" engagement of threaded rod and set screw. /� COuS Finish: Plain or Electro-Galvanized ' LISTED 39.71 Order By: Figure number and finish �� ® (3sa) Approvals: Underwriters Laboratories Listed '' 2(1 APPROVED (cULus)and FM Approved(FM)for up to 4" 09.o) (100mm) pipe. 1111 \.A , -iso ta- 0 Designed to meet or exceed requirements off FM DS 2-0 and NFPA 13. Set Screw and tie Locknut Included pts (U•2) (34.9) Part For Approx.Wt/100 No. Rod Size Lhs. (kg) 65XT '/e'-16 28.0 (12.7) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 14 B-Line series Fire Protection Solutions • Beam Clamps TOLCO Fig. 69 - Beam Clamp Retaining Strap Size Range: 3/s"-16 thru 3/4"-10 rod OAR 4"(101.6mm)thru 16'(406.4mm) lengths Note: longer lengths are available consult factory Material: Pre-Galvanized Steel ® 01.11 Function: To offer more secure fastening of various types of beam clamps to beam where danger of movement might I1431 be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies Fig.69-'/>'!_ requirements of NFPA 13. Important Note: Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly.Therefore a locking Detail A mechanism of some kind, such as a hex nut for the Fig.69 or the beveled locking slot of the Fig. 69R will provide a more secure reliable installation. Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada (cUL). Approved for use with any listed B-Line series or Tolco beam clamp. Finish: Pre-Galvanized Order By: Figure number, length (L), and finish. U, Note: Minimum return on strap is 1"(25.4mm). Lengths over 16"(406mm)are not UL Listed. E m ar Fig.69-s/a'!i 1�1 Hole Dia.D For Use With Length Part No. in. (mm) B3033-3/8,B3034 3/8,B3031-3/8, Specify = 1S1 69'1/4--'/2-L see Detail A 65 3/8,65XT-3/8,66 s/8 E 63033-1/2,B3034 1/2,65112,66 V2 69'/8-L 11/16' (17.5) B3033-'/a,65-8/8,66 5/8 Specify 691/4-L "Is" (20.6) 83033'/4 Specify lit = to • All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 17 Eaton Pipe Hangers 4. TOLCO Fig. 200 - "Trimline" Adjustable Band Hanger �T.'OL'CO g- 6" l:no" Idjusable Band LJ.."."...r with D.."..".yable N u•(For .izes 1"thru 9rr1 Size Range: " t Fig. 20000 - '/2" (15mm)thru 8" (200mm)pipe A C L SS Overall Height LISTED APPROVED Material: Steel, Pre-Galvanized 6 Function: For fire sprinkler and other general piping purposes. Knurled Center of pipe to top of knurled hanger rod nut. swivel nut design permits hanger adjustment after installation. 0 Top of pipe to bottom of hanger rod nut. Features: • '/2"(15mm)thru 2" (50mm)sizes have flared edges for ease of !� Fig. %i2 installation on all pipe types and protects CPVC plastic pipe from �V2& --,. („ abrasion.Captured knurled nut design (flared top) on 1"thru 2"sizes 200'' 4 0 keep nut from separating with hanger. Hanger is easily installed around pipe. , • 1/2"(15mm),3/4" (20mm),and 21/2'(65mm)thru 8" (200mm)) Spring C ij f - tension on nut holds it securely in hanger before installation. Knurled nut is easily removed. • For (15mm)and 3/a(20mm)sizes with non-captured knurl nuts order Fig. 200S f `,Approvals: Underwriters Laboratories listed (I/2"(15mm)thru 8"(200mm)) \-,, ( ,- Fig. in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and 2aForg.-i - Zoo-2rhto 2o0-s Factory Mutual Engineering Approved (FM) (3/4"(20mm)thru 8"(200mm)). 20od ,r f Conforms to Federal Specifications VWV-H-171 E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F(343°C) (:) „.., ! - Finish: Pre-Galvanized. Stainless Steel • materials will be supplied with (2) hex nuts .' n:, h, f n place of a knurl nut. �'� d 1 Order By: Part number and pipe size x c. s Note: For metric hanger rod sizes add the EC metric rod size to the figure number. :' Example: 200M8-11/2 or 200M10-11/2 ' Fig.200C Fig.200F Fig.200 Fig.200&Fig.200S t M8 rod size is not UL Listed or FM Approved 200C-1'/s shown 200E-11/s shown shown with captured nut shown with 1"thru 2"sizes only non-captured nut Pipe Size Rod Size A B D Max.Rec.Load Approx.Wt/100 Part No.' in. (mm) in. mm** in. (mm) in. (mm) in. (mm) lbs. (kN) lbs. (kg) 200-V3 '/2" (15) 3/8-l6 M8t or M10 31/B" (79.4) 25/3" (66.71 11y32'(34.1) 400 (1.781 11 (5.0) 200-'/4 3/4' (20) 3/8"-16 M8t or M10 3'/e" (79.4) 2'/2' (63.5) 11/16" (27.0) 400 (1.78) 11 (5.0) 200-1 1" (25) 3/u"-16 M8t or M10 33/e" (85.7) 25/B" (66.7) UN (28.6) 400 (1.78) 12 (5.5) 200-11/4 FA" (32) 3/a"-16 M8t or M10 33/4' (94.0) Vs" (73.0) 15/32" (29.3) 400 (1.78) 13 (5.9) 200.11/z 11/2" (40) 3/s"-16 Mt8 or M10 3'/e" (98.4) 2'/e" (73.0) 13/s" 130.2) 400 (1.78) 14 (6.4) 200-2 2" (50) 3/e°-16 M8t or M10 412" (114.3) 39/so" (80.8) 111s" (30.2) 400 (1.78) 15 (6.9) 200-2V2 21/2 (65) 3/8-16 M10 55/e' (142.9) 41/e" (104.7) 11/16" 136.5) 600 (2.67) 27 (12.3) 200-3 3" (75) 3/e-16 M10 57/8" (149.1) 4" (101.61 11/4" (31.7) 600 (2.67) 29 (13.3) 200-3'/2 372. (90) 3/a'-16 M10 73/a" (187.3) 5V4' (133.3) 23/is" (55.6) 600 (2.67) 34 (15.6) 200-4 4" (100) '/a"-16 M10 73/e" (187.3) 5" (127.0) 1'/e' (34.91 1000 (4.45) 35 (16.0) 200-5 5" (125) 1/2"-13 M12 91/8" (231.8) 6'/4" (158.7) 3'1/n' (84.9) 1250 (5.56) 66 (30.2) 200-6 6" (150) 1/2"-13 M12 101/s" (257.2) 63/a' (171.4) 2'/a2" (56.3) 1250 (5.56) 73 (33.4) 200-8 8" (200) 1/2"-13 M12 131/a" (333.4) 83/4' (222.2) 3'/n' (81.7) 1250 (5.56) 136 (62.3) All dimensions in charts and on drawings are ire inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Fire Protection Solutions 23 Eaton Bulletin 014 December 2021 CO Model Fl FR Series rielbitQuick Response s 'a Glass Bulb Sprinklerscp5' CT Model F1 FR56 Sprinkler Types Standard Spray Upright - ` • _ N Standard Spray Pendent ��j VIConventional Upright/Pendent Vertical Sidewall Horizontal Sidewall g -° YModel Fl FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent cn Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types x Standard Spray Pendent ea Model F1FR42, F1 FRXLH & F1 FR28 Sprinkler v Types Vertical Sidewall Horizontal Sidewall Recessed Standard Spray Upright ci Y Standard Spray Pendent Pendent/F1 F2 - Model F1 FR40 Sprinkler Types YStandard Spray Pendent `/ '+f NE, Model F1FR42, F1 FR40, F1 FRXLH & F1FR28 '' �* .. o Recessed Sprinkler Types t �r ` .� Standard Spray Pendent Model F1 FR56LL&F1 FR42LL Low Lead Sprinkler Recessed Concealed Recessed m Types Horizontal Sidewall Pendent Pendent/FP lti$ Standard Spray Pendent with less than 0.25% Lead Con- o tent y Listing &Approvalsgl el IP 9 The following organizations provide Listings or Approvals for 3 various Model F1 FR series sprinklers. See the Design and 2 Installation table in this Bulletin for information on specific XLH Upright XLH Pendent XLH Recessed listings and approvals applicable to each sprinkler. Pendent F1/F2 m 1. Underwriters Laboratories Inc.and Certified for Cana product Description tion a da (cULus) in accordance with ANSI/UL199. Reliable Model F1FR series sprinklers ui 2. FM Approvals (FM) P o 3. Loss Prevention Certification Board (LPCB) are quick-response automatic sprinklers c 4. VdS Schadenverhiltung GmbH (VdS) with a glass bulb thermal element. Model N F1 FR series sprinklers are Standard Spray cc, 5. Underwriters Laboratories Inc. and Underwriters Lab- c oratories of Canada Certified for Health Effects to NSF/ sprinklers,with the exception of the Model al ANSI Standard 61 Annex G (ULH) F1 FR56 Conventional sprinkler which is XLH Recessed 6. EC 0786-CPD-40239 0786- an Old-style/Conventional sprinkler. Pendent FP CPD-40251 Certificate: 078(RA1425), 0786-CPD-40252(RA1414), 5) The Model F1FR Series automatic sprinklers utilize a 3.0 (EC) mm frangible glass bulb. These sprinklers have demonstrated 7. (EC) ark certified. Certificate Number 23347.(WM) response times in laboratory tests which are five to ten times faster than standard response sprinklers.This quick response UL Listing Category enables the Model Fl FR Series sprinklers to apply water to a Sprinklers,Automatic&Open (VNIV) fire faster than standard-response sprinklers of the same tern- Quick Response Sprinkler perature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule.This glass bulb is specially constructed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in Model F1FR Series sprinklers must be installed with the Reli- both the liquid and vapor phases.The vapor phase can be seen able sprinkler installation wrench identified in the Design'and as a small bubble.As heat is applied,the liquid expands,forcing Installation Information table in this Bulletin.Any other wrench the bubble smaller and smaller as the liquid pressure increases. may damage the sprinkler. A leak tight sprinkler joint can be Continued heating forces the liquid to push out against the bulb, obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). Do not causing the glass to shatter,opening the waterway and allowing tighten sprinklers over the maximum recommended installation the deflector to distribute the discharging water. torque. Exceeding the maximum recommended installation Model F1FR Series sprinklers provide a wide range of options torque may cause leakage or impairment of the sprinkler. where quick-response,glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal side- Model F1FR Series Recessed sprinklers are to be installed wall, and vertical sidewall deflectors as shown in Fig. 1,Fig.2,or Fig.3,as applicable to the specific • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 model being installed.The Recessed Escutcheon Data table in metric), and 5.6 (80 metric) the Bulletin identifies the only recessed escutcheons that are • Flush, recessed, and concealed installations permitted to be used with each Model Fl FR Series Recessed See the Design and Installation Information table in this Bul- sprinkler.The use of any other recessed escutcheon will void all a� letin for information on the approvals and availability of specific approvals and negate all warranties. Model Fl FR series sprinkler configurations. Concealed Sprinklers 0_ Model F1FR Recessed Pendent and Recessed Horizontal Model Fl FR Series Concealed Pendent sprinklers are to Sidewall sprinklers are required to be used with Reliable Model be installed as shown in Fig. 4 or Fig. 5, as applicable to the X F1, F2, or FP recessed escutcheons. See the Recessed Es- selected cover plate. Model Fl FR56 Concealed Pendent and cutcheon Data table in this Bulletin for listing and approval infor- Model F1 FR56LL Concealed Pendent sprinklers have a facto- mation with each specific Model F1FR series sprinkler. Model ry-installed Model CCP cup.A protective cap is installed at the Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are factory that should remain on the sprinkler until the sprinkler is d a friction fit assembly allowing for 3/4-inch (19mm) and 1/2- installed and should then be reinstalled on the sprinkler until the Y inch(12.7mm)of adjustment,respectively.Model FP recessed cover plate is installed.The concealed sprinkler assemblies are co. escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) completed by the installation of a Model CCP push-on/thread- threaded adjustment. off cover plate assembly.The cover plate and sprinkler cup as- Model F1 FR56 Concealed Pendent and Model F1 FR56LL semblies are joined using a cover plate skirt with flexible tabs Concealed Pendent sprinklers are required to be used with for threaded engagement. A choice of two Model CCP cover N Model CCP cover plates.A standard profile Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch plate is available that provides up to 1/2-inch(12.7mm)of cover (8mm) of cover adjustment. Do not install Model F1FR Series c plate adjustment. In addition, a low profile Model CCP cover Concealed Pendent sprinklers in ceilings which have positive plate is also available that provides up to 5/16-inch(8.0mm)of pressure in the space above. a cover plate adjustment. See the Design and Installation Infor- Model F1FR Series Concealed Pendent sprinklers require mation and Listed and Approved Temperature Ratings tables a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The in this Bulletin for further information on approved cover plate Model W4 wrench is used to engage the sprinkler wrenching sur- o options. faces and to install the sprinkler in the fitting.Remove the protective Application cap to install the sprinkler,then reinstall the protective cap until the a Model F1FR Series sprinklers are intended for use in ac- cover plate is installed.When inserting or removing the wrench from 0 cordance with NFPA 13, FM Property Loss Prevention Data the sprinkler/cup assembly,care should be taken to prevent dam- Sheets, and the requirements of the Authority Having Juris- age to the sprinkler.Do not wrench any other part of the sprinkler/ d diction. Care must be exercised that the k-factor, tempera- cup assembly.Installation is completed by removing the protective ture rating, deflector style, and sprinkler type are in accor- cap from the sprinkler and pushing the cover plate onto the cup. z dance with the requirements of the applicable design and Final adjustment is made by hand turning the cover plate until the N installation standards. In addition, Model F1FR Series sprin- skirt flange makes full contact with the ceiling.Cover plate removal o klers must be used in accordance with their listings and ap- requires turning the cover plate in the counter dockwise direction. provals, as well as the information provided in this Bulletin. After installation,inspect all sprinklers to ensure that there is a gap -) between the cover plate and ceiling and that the four cup slots are Installation Glass bulb sprinklers have orange bulb protectors or protec- open and free from any air flow impediment to the space above. tive caps to minimize bulb damage during shipping, handling Concealed cover plate/cup assemblies are listed only for use and installation. Reliable sprinkler installation wrenches are with specific sprinklers.The use of any concealed cover plate/ designed to install sprinklers with bulb protectors in place. Re- cup assembly other than the Reliable Model CCP with Model move the bulb protector at the time when the sprinkler system is F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed placed in service for fire protection.Removal of the bulb protec- Pendent sprinklers or the use of the Model CCP Concealed tor before this time may leave the bulb vulnerable to damage. cover plate assembly on any sprinkler with which it is not spe- Remove bulb protectors by undoing the clasp by hand. Do not cifically listed my prevent good fire protection and will void all use tools to remove bulb protectors. guarantees,warranties,listings and approvals. 2. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100a/o Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Nominal Nominal Nominal K-factor Orifice Deflector/ Sprinkler Installation Listings Approval Model Diameter Height SIN and Orientation Wrench Approvals Notes US Metric inches mm inches mm Pendent 2.25 57 W2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 W4 RA1411 cULus 2 a) Upright 2.25 57 W2 RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS a.. Recessed Pendent 2.25 57 W4 RA1418 VdS co i Pendent 2.25 57 W2 RA1413 cULus 2 x F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 c c Upright 2.25 57 W2 RA1423 cULus 1,2 m N F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus,ULH Y Recessed Pendent 2.25 57 W4 RA1410 cULus,ULH o F1FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 Y (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 co- with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 Y cULus, FM, o Pendent 2.25 57 W2 RA1414 LPCB,VdS,EC, 1,2,3,4 u) WM o cULus, FM, �' Recessed Pendent 2.25 57 W4 RA1414 LPCB,VdS,EC, 1,2,3,4 a) WM m F1FR56 5.6 80 1/2 15 cULus,VdS,EC, -ao Concealed Pendent 2.25 57 W4 RA1414 WM 5,6 rs 0 cULus,FM, o Upright 2.25 57 W2 RA1425 LPCB,VdS,EC, 1,2,3,4 a) WM a "Conventional LPCB,VdS,EC, 3 (Pendent or Upright)" 2.25 57 W2 RA1475 WM 4 a) Pendent 2.25 57 W2 RA1415 cULus,ULH 1 0) F1FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 W4 RA1415 cULus,ULH a) ca Concealed Pendent 2.25 57 W4 RA1415 cULus,ULH 6 a Horizontal Sidewall 2.63 67 W2 RA1435 cULus,FM 1,2,3,7 diF1 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 W4 RA1435 cULus,FM 8 l- Sidewall O Z Vertical Sidewall(Pen- cULus,FM, N F1FR56 5.6 80 1/2 15 dent or Upright) 2.25 57 W2 RA1485 LPCB 1,2,3,9 o (1)cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. m (2)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. 0)Available with FM approved Polyester coating in black or white. (4)Available with LPCB and VdS approved Polyester coating. psi VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F(68°C)temperature rated sprinklers only.VdS approved sprinklers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. i°Model Fl FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates,available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/16-inch(8.0 mm)of adjustment. p1 cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches(102mm to 305mm).FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. j)cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. M The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies.LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Deflector) 100°F(38°C)Max.Ambient 150°F(65°C)Max.Ambient 225°F(107°C)Max. Model Orientation Temp. Temp. Ambient Temp. 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) 286°F(141°C)Temp. Temp.Rating Temp.Rating Temp.Rating Temp.Rating Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus FIFR28 Recessed Pendent cULus Upright cULus FIFR40 Pendent VdS Recessed Pendent VdS Pendent cULus F1FR42 Recessed Pendent cULus co Upright cULus Y Pendent cULus,ULH c F1FR42LLE. Recessed Pendent � :� cULus,ULH co � Pendent cULus = FIFRXLH Recessed Pendent cULus x Upright cULus c Pendent cULus,FM,LPCB,VdS,EC,WM c m Recessed Pendent cULus.FM, LPCB,VdS, EC,WM `\l cULus,VdS,EC, Y F1FR56 Concealed Pendent* cULus,WM WM cULus,WM c Upright cULus,FM,LPCB,VdS,EC,WM Y "Conventional ozi Pendent or U.ri.ht " LPCB,VdS,EC,WM rNi Pendent C#1- H* ✓". �� ". cULus,ULH oFIFR56LL Recessed Pendent to. `° ,�, cULus,ULH co Concealed Pendent* -*ix ' »fir cULus,ULH o Horizontal Sidewall cULus,FM F1FR56 Recessed Horizontal cULus,FM > Sidewall Vertical Sidewall(Pen- a> F1FR56 dent or Upright) cULus,FM,LPCB $ * Model Fl FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP o cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For In- :-' termediate Temperature Classification sprinklers use a 165°F (74°C)temperature rated cover plate. CO aa>i Recessed Escutcheon Data a> w Listed and Approved Recessed Escutcheons N Model F1 Model F2 Model FP as Deflector/ d Model Orientation (Fig. 1 &3) (Fig. 1 &3) (Fig.2) SIN w 3/4-inch(19mm) 1/2-inch(12.7mm) 1/2-inch(12.7mm) 1— adjustment adjustment adjustment z z FIFR28 Recessed Pendent cULus cULus cULus RA1411 NI FIFR40 Recessed Pendent VdS VdS VdS RA1418 o F1FR42 Recessed Pendent cULus cULus cULus RA1413 c FIFR42LL Recessed Pendent cULus, ULH cULus,ULH cULus,ULH RA1410 1 FIFR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus,LPCB,VdS, cULus, FM, LPCB, cULus,VdS,EC,WM RA1414 EC,WM VdS,EC,WM FIFR56LL Recessed Pendent cULus, ULH cULus,ULH cULus,ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus,FM cULus RA1435 4. 7" x 7/2" REDUCING TEE OR ELBOW - - TP Th.— — 11 I 2 5/8" DIA. 2 5/16" DIA '� __ �' HOLE IN CEILING CUP _.�4m f, 1 III�II[ 11-11FI 1 1/2 MAX,,, FACE OF FITTING I I " " TO FACE OF CEILING .4_,./ r. I " " !�� i�l """" DIMENSION III iiiiii. CEILING " " iiiil - -' - m. P 5/16" MAX. �� 3/4" m COVER ADJUSTMENT �� c fa. COVER PLATE— u) ASSEMBLY I - 3 5/16" DIA. - X SPRINKLER / a c as CONCEALED, 5/16" ADJUSTMENT onroozn C‘i Y Fig. 5-Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16- cir inch(8.0mm) adjustment-Model CCP cover plate v Maintenance Material Data Y The Model F1FR Series sprinklers should be inspected and Frame: DZR Brass,QM Brass,or Low Lead Brass o the sprinkler system maintained in accordance with NFPA 25. In c Do not clean sprinklers with soap and water, ammonia or any Deflector: CDA Alloy 220,260,or 510 N other cleaning fluids.Remove dust by using a soft brush or gen- Load Screw\Pintle: CDA Alloy 360 or 544 > tIe vacuuming. Replace any sprinkler which has been painted Cup: CDA Alloy 651 or 693 O (other than factory applied)or damaged in any way.A stock of Washer: Nickel Alloy 440 or 360,coated with PTFE n spare sprinklers should be maintained to allow quick replace- Adhesive Tape m ment of damaged or operated sprinklers. Bulb: Glass Finishes (1)(2) w .N Standard Finishes OrderingInformation sa Sprinkler Escutcheon Cover plate 3 Bronze Brass Chrome Specify: ci) Chrome Chrome White . 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] co White Polyester(3)(6)(7) White a) Special Application Finishes [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] m Sprinkler Escutcheon Cover plate 2. Sprinkler Deflector/Orientation: [Pendent][Recessed a Electroless Nickel Electroless Nickel Pendent][Upright][Conventional][Horizontal Sidewall] Bright Brass w PTFEj3 4 PTFE g [Recessed Horizontal Sidewall][Vertical Sidewall] l- Black Polyester(3)(6)(7) Bright Brass Black O Bright Brass(5) Black Off White 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] z Off Whitej6N'> Off White Satin Chrome 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F o Satin Chrome Satin Chrome (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] rNi ("Other finishes and colors may be available on special order. Consult the 5. Sprinkler Finish factory for details. 6. Escutcheon Model: [F1][F2][FP] (2)Paint or any other coating applied over the factory finish will void all approvals and warranties. 7. Escutcheon Finish (where applicable) f3i cULus Listed as Corrosion Resistant. 8. Cover plate Model: [standard profile CCP 1/2-inch (4) FM Approved as Corrosion Resistant for SIN RA1414,RA1425, RA1435, (12.7mm) adjustment][low profile CCP 5/16-inch and RA1485. (8.0mm) adjustment] (5) 200°F(93°C)maximum temperature rated sprinkler only. i">VdS Approved for RA1425,RA1414,RA1418,and RA1475. 9. Cover plate Temperature Rating: [135°F (57°C) for use a> LPCB Approved for RA1425,RA1414,and RA1475. with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note:When Model F1FR Series Recessed sprinklers are ordered,the sprin- klers and escutcheons are packaged separately. 7. Bulletin 013 November 2019 W. Reliable 0 Models Fl Series p Standard Response w Sprinklers o n C il?Model F156 Sprinkler Types o Standard Upright Standard Pendent 78 Conventional ,rg 1, II Vertical Sidewall Horizontal Sidewall =s Model F156 Recessed Sprinkler Types Upright Pendent Conventional Pendent/F1/F2/FP Horizontal Sidewall Model F142, F1XLH & F128 Sprinkler Types q ....4i 0 Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Vertical Sidewall Horizontal Sidewall Recessed Types Pendent/F1/F2 Pendent/F1/F2/FP Approval Organizations 1. Underwriters Laboratories Inc. and certified for 4 V1� Canada (cULus) ill 2. Factory Mutual Approvals(FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhi tung GmbH Recessed Recessed XLH Upright 5. EC Certificate: 0786-CPD-40237 (RA1314) Horizontal Sidewall Pendent/FP 0786-CPD-40253 (RA1325) 0786-CPD-40254 (RA1375) UL Listing Category Sprinklers,Automatic&Open (VNIV) tilD --k4, , Product Description XLH Pendent XLh Recessed XLH Recessed The F156, F142, F1XLH & F128 Series Glass Bulb PendentFl/F2 Pendent FP Sprinkler combines the durability of a standard sprinkler The F156, F142, F1XLH&F128 Series Automatic Sprin- with the attractive low profile of a decorative sprinkler. kler utilizes a 5.0 mm frangible glass bulb.The glass bulb Whether installed on exposed piping or in an office ceil- consists of an accurately controlled amount of special ing, it is functional and attractive. fluid hermetically sealed inside a precisely manufactured Beautifully versatile is the description for the Reliable glass capsule.This glass bulb is specially constructed to Models F156, F142, F1XLH & F128 Series Recessed provide fast thermal response. glass bulb sprinkler. Recessing the F156, F142, F1XLH& At normal temperatures, the glass bulb contains the F128 Series enhances its already low profile decorative fluid in both the liquid phase and in the vapor phase.The appearance, and facilitates a rapid and perfect installa- vapor phase can be seen as a small bubble. As heat is tion. applied, the liquid expands forcing the bubble smaller The recessed escutcheon of the Models F156, F142, and smaller as the liquid pressure increases. Continued F1XLH & F128 are highly adjustable. The two piece con- heating forces the liquid to push out against the bulb, struction makes field installation a very easy and rapid causing the glass to shatter, opening the waterway and task. This also allows ceiling panels to later be removed allowing the deflector to distribute the discharging water. without shutting down the fire protection system, thus fa- The F156, F142, F1XLH & F128 Series Sprinkler tern- cilitating maintenance of above ceiling services, perature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F156, Upright, Pendent & Conventional Sprinklers Model F142, F1XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench Installation Data: Nominal Thread Nominal K-Factor Sprinkler Approval Sprinkler Identification Number Orifice Size US i Metric Height Organization Upright (SIN) Pendent Standard-Upright(SSU)and ndent Deflectors Marked to Indicate Position Y"(15mm)(1) Y2"NPT(R1/2) 5.6 80 �2.25"(57mm) 1,2,3,4,5 RA1325(2)(3)r5Xi6r RA1314(2)(3)(51(6) 7/6"(10mm) ' "NPT(R1/2) 4.2 60 2.25"(57mm) 1 RA1323(2)(6) RA1313(6) 3/a"(10mm) Y2"NPT(R1/2) 2.8 40 2.25"(57mm) 1 RA1321(S)(0) RA1311(6) Conventional-Install in Upright or Pendent Position 15mm(1) 1/2"NPT(R1/2) 5.6 80 I 57mm 3,4,5 RA1375(5) r'1 Refer to Bulletin 024 for Special Response Sprinklers(F1S5-56) (2)cULus Listed corrosion resistant(Polyester coated)sprinkler. P)Polyester coated FM Approved sprinkler. ai (6)Polyester coaled LPCB&VdS approved sprinkler RA1325,RA1314&RA1375. (6)Electroless Nickel PTFE Plated -UL listed Corrosion Resistant 0 _, '... Upright Pendent Conventional Model F156, F142, F1XLH & F128 Recessed Pendent Sprinklerst'I Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread Nominal K-Factor Sprinkler Sprinkler Identification Number Orifice Size US Metric Height (SIN) 1/2"(15mm) 1/2"NPT(R1/2) 5.6 80 2.25" (57mm) RA1314(2) 7/,611(10mm) 1/2"NPT(R1/2) 4.2 60 2.251E (57mm) RA1313(2) 3/"(10mm) 'h"NPT(R1/2) 2.8 40 2.25"(57mm) RA1311(2) 1'1 Refer to escutcheon data table for approvals&dimensions (2)Electroless Nickel PTFE Plated -cULus listed Corrosion Resistant —'I/n.-NIXE d4 mJ L 1'A'r/I REDUCER Frs--I-� l T 5/B'0/l[6G)mm7 ' MdN P MOLE IN MENG ERERNT NAN Caton Y \ FAO(or rarue z s/+a'ON.Cu Ise rm„N7 -- To FACE of MIRO DANENERN Crm I I _I/i Erlm f -� i ''A' mwow"Aasrss-rTt';,^ ��///�� - /eTas...mJ muN6 'tom_ Ty �Y/I J To ESXEMNEav y rOEF"�CC OF CEILING - 1 AiRECESS MONISM �,-✓/,71vmm1 Illlll[-1]'L♦IIIIIII DIMENSION i/] rvmmJ A i��1� /jjl�� AT MVANN RECESS I-r/T7mmm] At u sn w •r Em�ZOwm" AT MM/MUM RECESS- r 7zsa„m,] or r ww REcrss-F/W7n zmml Ifl%�/Y// IJ1 Ar M Ncccss.'-vat"a..�,r n svnncrroa e p AT MUNSON RECESS-'TSR. E.amm] Ar=rgl-r-V"Pe sm 1 '7soamml JJ �. l:. AT ANERfuM access- 1725 MI] Ar MLvruuu arcEAS-r-s/e�r�mmmm,"J AwusTMEMM z iiia ON2DIL feiam,gl RECESSED PENDENT W/F1 OR F2 ESCUTCHEON RECESSED PENDENT W/FP ESCUTCHEON P„Pau,R 'SPRINKLER NO)RN APPROVED wan F:[5CNCFFON 'SPRINKLER NOT FM APPROVED WEN FP ESCUTCHEON Model F156,F142,F1XLH&F128 F1 or F2 Model F156,F142, F1XLH&F128 FP 3. Application Maintenance Model F156,F142,F1XLH,F128&Model F156,F142,F1XLH& The Model F156, F142, F1XLH&Model F156, F142, F1X- F128 Recessed sprinklers are used in fixed fire protection systems: LH & F128 Recessed Sprinklers should be inspected and Wet,Dry Deluge or Preaction. Care must exercised that the orifice the sprinkler system maintained in accordance with NFPA size,temperature rating,deflector style and sprinkler type are in ac- 25. Do not clean sprinklers with soap and water, ammonia cordance with the latest published standards of the National Fire or any other cleaning fluid. Replace any sprinkler which has Protection Association or the approving Authority Having Jurisdic- been painted (other than factory applied) or damaged in tion Installation. any way. A stock of spare sprinklers should be maintained Installation to allow quick replacement of damaged or operated sprin- Model F156, F142, F1XLH & F128 Series sprinklers are stan- klers. Prior to installation, sprinklers should be maintained dard response sprinklers intended for installation as specified in in the original cartons and packaging until used to minimize I NFPA 13.They must also be installed with the Model W2 Sprinkler the potential for damage to sprinklers that would cause im- Wrench specifically designed by Reliable for use with these sprin- proper operation or non-operation. klers, Temperature Ratings The Model F156, F142, F1XLH & F128 Recessed Sprinklers I Sprinkler Max.Ambient Bulb are to be installed with a maximum recess of 3/4 inch(19mm).The Classification TeCmperatuF Temp. Color Model F1,F2,and FP Fscutcheon illustrated are the only recessed Ordinary 57 135 100°F(38°C) Orange escutcheon to be used with the Model F156,F142,F1XLH&F128 Ordinary 68 155 100°F(38°C) Red Recessed Sprinklers.The use of any other recessed escutcheon Intermediate 79 175 150°F(66°C) Yellow will void all approvals and negate all warranties. When installing Intermediate 93 200 150°F(66°C) Green Model F156, F142,F1XLH&F128 Recessed Sprinklers use the Highltl 141 286 225°F(107°C) Blue Model GFR2 Sprinkler Wrench. Myothertype of wrenchExtraa HHigh (1)(2) 182 500 4730 °F(146°C) Mauve may Ultra High(1112) 260 500 475°F(246°C) Black damage these sprinklers. 111 Not available for recessed Sprinklers. Nate:A leaktight 1/2"NPT(R1/2)sprinkler joint can be obtalned with (2)cULus listed for SIN RA1325 and RA1314 only. a torque of8-18ft-Ibs(11-24N-m). Do not tighten sprinklers over Maximum Working Pressure maximum recommended torque. It may(al ise leakage or impair- 175 psi (12 bar) ment of the sprinklers. SIN RA1325& RA1314 cULus listed for 250 psi (17 bar) Glass bulb sprinklers have orange covers to protectthe bulb dur- 100% Factory tested hydrostatically to 500 psi (34.5 bar) ing the installation process. REMOVE THIS PROTECTION ONLY Finish11 AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED Standar Finishes AND,WHEN APPLICABLE,THE ESCUTCHEONS HAVE BEEN Sprinkler Escutcheon INSTALLED. RASCO wrenches are designed to install sprinklers Bronze Brass Chrome Chrome when covers are in place. Polyester Coated(6)17X91 White Painted Ordering Information Special Application Finishes Sprinkler Escutcheon Specify: Electroless Nickel PTFE3r101 Electroless Nickel FIFE 1. Sprinkler Model Bright Brassl21 Bright Brass 2. Sprinkler Type Black Plated Black Plated 3. Nominal K-Factor Black Paint13X91 Black Paint 4. Temperature Rating Off Whitel3X9l Ott White 5. Sprinkler Finish Chrome Dull Chrome Dull 6. Thread Type: [1/2" NPT] [ISO 7-1R1/2] Lead Plated13X^X81 7. Escutcheon Finish (where applicable) Wax Coatedl3814115gel Note:When Models F156, F142, F1XLH & F128 Recessed Sprinklers Wax Over Leadl3Xat5381 are ordered,the sprinklers and escutcheons are packaged separately. rn Other colors and finishes are available on special order.Consult factory for Escutcheon Data(1) details.Custom color painted sprinklers may not retain their UL Corrosion resistance listing. SIN:RA1335-cULus and FM permits use with Fl or F2 escutcheons for light (2)200°F(93°C)maximum. hazard only tat UL and ULC listed only. 01155°F to 200°F(68°C to 93°C)ratings only. 15)286°F(141°C)sprinklers may be coated for ambient conditions not exceeding 150°F(66°C). l61 cULus listed"corrosion resistant"applies to SIN Number RA1325(Upright) RA1323 (upright), RA1321(Upright), RA1325 (HSW), RA1385(VSW) and RA1314(Pendent)in standard black or white.Corrosion resistance in other polyester colors is available upon request. m FM Approved finish as"Polyester Coated"applies to SIN number RA1314, RA1335&RA1325 in standard black or white. (8)FM Approved finish applies only to SIN number RA1335&RA1385. (9)LPCB and VdS Approved finish applies only to RA1325,RA1314 and RA1375. 1101 cULus listed Corrosion Resistant applies to SIN RA1325,RA1314,RA1323, RA1313,RA1321,FA1311,RA1385 and RA1335 5. Worldwide www.tyco-fire.com t11c1.:7 Contacts Series DS-2 Dry-Type Sprinklers 11.2K Pendent Standard and Quick Response, Standard Coverage General Series DS-2 Dry-Type Sprinklers must only be installed in fittings that meet Description the requirements of the Design Crite- ria section. TYCO Series DS-2 Dry-Type Sprin- f j klers, 11.2K Pendent, Standard (5 mm Sprinkler bulb)and Quick Response(3 mm bulb), and Standard Coverage are decorative Identification glass bulb automatic sprinklers typi- cally used where: • pendent sprinklers are required on TY5255—Standard Response dry pipe systems that are exposed TY5235—Quick Response ./ ,' to freezing temperatures(e.g.,sprin- j kler drops from unheated portions of Technical buildings) k r • sprinklers and/or a portion of the Data - connecting piping may be exposed to freezing temperatures(e.g.,sprin- Approvals `♦ J kler drops from wet systems into UL and C-UL Listed * %.- fit. ./ freezers) NYC Approved under MEA 173-02-E NOTICE See Table A. Series DS-2 Dry-Type Sprinklers Maximum Working Pressure described herein must be installed 175 psi(12,1 bar) Operation and maintained in compliance with this Inlet Thread Connections When TYCO Series DS-2 Dry-Type document,as well as with the applica- 1 in.NPT Sprinklers, 11.2K Pendent, Standard ble standards of the NATIONAL FIRE ISO 7-R 1 5 mm bulb)and Quick Response(3 mm PROTECTION ASSOCIATION (NFPA), bulb), and Standard Coverage are in in addition to the standards of any other Discharge Coefficient service,water isprevented from enter- authorities having jurisdiction. Failure See Table C. ing the assembly y the Plug with Gas- to do so may impair the performance Temperature Ratings keted Spring Plate Seal (see Figure 1) of these devices. See Table A. in the Inlet of the sprinkler. The owner is responsible for main- Finishes The glass bulb contains a fluid that taining their fire protection system Sprinkler:See Table D. expands when exposed to heat.When and devices in proper operating con- Escutcheon:See Table D. the rated temperature is reached, the dition. Contact the installing contrac- tor or product manufacturer with any Physical Characteristics fluid expands sufficiently to shatter questions. Inlet Copper released Copper the s bulb, and the Bulb Seat is Yoke Stainless Steel Casing Galvanized Carbon Steel The compressed Spring is then able IMPORTANT Insert Bronze to expand and push the Water Tube as Bulb Seat Bronze well as the Guide Tube outward. This Refer to Technical Data Sheet Bulb Glass action simultaneously pulls inward on TFP2300 for warnings pertaining to Compression Screw Bronze the Yoke, withdrawing the Plugwith regulatory and health information. Deflector Bronze Gasketed Spring Plate Seal fro the Frame Bronze p g Always refer to Technical Data Guide Tube Stainless Steel Inlet, allowing the sprinkler to activate Sheet TFP700 for the `INSTALLER Water Tube Stainless Steel and flow water. WARNING"that provides cautions Spring Stainless Steel Gasketed Spring with respect to handlingand instal- Plate Seal Beryllium Nickel w/TEFLON p Pin Stainless Steel lation of sprinkler systems and corn- Button Spring Stainless Steel ponents. Improper handling and Escutcheon Carbon Steel installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 SEPTEMBER 2021 TFP530 TFP53O • Page 2 of 8 TY5255 Design Standard Response TY5235 Criteria Quick Response TYCO Series DS-2 Dry-Type Sprinklers, 11.2K Pendent, Standard (5 mm bulb) with Flush Escutcheon and Quick Response(3 mm bulb),and (Figure 2) Standard Coverage are intended for with Recessed Escutcheon use in fire sprinkler systems designed Temperature Bulb (Figure 3) in accordance with the standard Rating Color Code coverage installation rules recog- with Extended Escutcheon nized by the applicable listing agency (Figure 4) (e.g., UL Listing is based on NFPA 13 without Escutcheon requirements). (Figure 5) Sprinkler Fittings Install 1 in. NPT Series DS-2 Dry-Type SPRINKLER FINISH Sprinklers in the 1 in.NPT outlet or run of the following fittings: Natural Chromed Signal Brass Plated White • malleable or ductile iron threaded 135°F(57°C) Orange tee fittings that meet the dimensional requirements of ANSI 816.3 (Class 155°F(68°C) Red 150) • cast iron threaded tee fittings that 175°F(79°C) Yellow 1,2,3 meet the dimensional requirements 200°F(93°C) Green of ANSI B16.4(Class 125) Do not install Series DS-2 Dry-Type 286°F(141°C) Blue Sprinklers into elbow fittings.The Inlet Notes: of the sprinkler can contact the interior 1. Listed by Underwriters Laboratories,Inc.(UL),maximum order length of 48 inches of the elbow. 2. Listed by Underwriters Laboratories for use in Canada(C-UL).maximum order length of 48 inches The unused outlet of the threaded tee is 3. Approved by the City of New York under MEA 173-02-E TABLE A plugged as shown in Figure 9. SER/ES DS-2 STANDARD& QUICK RESPONSE, STANDARD COVERAGE You can also install Series DS-2 Dry- DRY-TYPE PENDENT SPRINKLERS Type Sprinklers in the 1 in. NPT outlet LABORATORY LISTINGS AND APPROVALS of a GRINNELL Figure 730 Mechanical Tee.However,the use of the Figure 730 q�,��y� Tee for this arrangement is limited to PLUG WITH ._ �', --- INLET wet pipe systems. n GASKETED SPRING 1 PLATE SEAL IIIP The configuration shown in Figure 8 is PIN only applicable for wet pipe systems i �_.f where the sprinkler fitting and water- SPRING �Y -` filled pipe above the sprinkler fitting 7' _li �V YOKE are not subject to freezing and where ('�, the length of the dry-type sprinkler has INLET BAND 14 PLUG the minimum exposure length depicted Z SPRING in Figure 10. See the Exposure Length WATER TUBE 1 section. f�/t i For wet pipe system installations of 1 el CASING in. NPT Series DS-2 Dry-Type Sprin- GUIDE li klers connected to CPVC piping, use TUBE 41 � INSERT only the following TYCO CPVC fittings: t� tt • 1 in.x 1 in.NPT Female Adapter(P/N VENT HOLE :I MO I�O SEAT 80145) • 1 in.x 1 in.x 1 in.NPT Sprinkler Head illall ��l Adapter Tee(P/N 80249) FRAME 3 or 5 mm For dry pipe system installations, BULB use only the side outlet of maximum COMPRESSION /I�cy'� 2 1/2 in. reducing tee when locat- SCREW 0° DEFLECTOR ing Series DS-2 Dry-Type Sprinklers -•-1111,--- directly below the branchline. Oth- FIGURE 1 erwise, use the configuration shown SERIES DS-2 STANDARD& QUICK RESPONSE in Figure 9 to assure complete water DRY-TYPE PENDENT SPRINKLER drainage from above Series DS-2 Dry- ASSEMBLY Type Sprinklers and the branchline. Failure to do so may result in pipe freezing and water damage. . TFP53O Page 3 of 8 Clearance Space Temperatures for Heated Areal In accordance with Section 8.4.9.2 of the 2010 edition of NFPA 13,when con- Ambient Temperature 40°F 50°F 60°F necting an area subject to freezing and Exposed to (4°C) (10°C) (16°C) p an area containing a wet pipe sprinkler Discharge End of Sprinkler Minimum Exposed Barrel Length2, system, the clearance space around Inches the sprinkler barrel of dry-type sprin- (mm) klers must be sealed. Due to tempera- ture differences between two areas,the 40°F 0 0 0 potential for the formation of conden- (4°C) sation in the sprinkler and subsequent 30°F ice build-up is increased. If this con- (-1°C) 0 D 0 densation is not controlled,ice build-up can occur that might damage the dry- 20°F 4 0 0 type sprinkler and/or prevent proper (-7°C) (100) operation in a fire situation. 10°F 8 1 Use of the Model DSB-2 Dry Sprin- (-12°C) (200) (25) 0 kler Boot, described in Technical Data Sheet TFP591 and shown in Figure 11, 0°F 12 3 0 can provide the recommended seal. (-18°C) (305) (75) -10°F 14 4 1 (-23°C) (355) (100) (25) -20°F 14 6 3 (-29°C) (355) (150) (75) -30°F 16 8 4 (-34°C) (405) (200) (100) -40°F 18 8 4 (-40°C) (455) (200) (100) -50°F 20 10 6 (-46°C) (510) (255) (150) -60°F 20 10 6 (-51°C) (510) (255) (150) Notes: 1. For protected area temperatures that occur between values listed above,use the next cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph(18.6 kph). TABLE B EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS NOTICE Exposure Length Do not install Series DS-2 Dry-Type When using dry sprinklers in wet pipe Sprinkler into any other type fitting. sprinklerto systemsree to temperatures,protect areas Failure to use the appropriate fitting subject freezingins pink use may result in one of the following: Table B to determine a sprinkler's appropriate exposed barrel length to • failure of the sprinkler to operate prevent water from freezing in the con- properly due to formation of ice netting pipes due to conduction. The over the Inlet Plug or binding of the exposed barrel length measurement Inlet Plug must be taken from the face of the • insufficient engagement of the sprinkler fitting to the surface of the structure or insulation that is exposed Inlet pipe-threads with consequent to the heated area. See Figure 10 for leakage an example. Drainage For protected area temperatures In accordance with the minimum between those given above, the requirements of the NATIONAL FIRE minimum recommended length from PROTECTION ASSOCIATION for dry the face of the fitting to the outside of pipe sprinkler systems, branch, cross, the protected area may be determined rmined and feed-main piping connected to dry by interpolating between the indicated sprinklers and subject to freezing tern- values. peratures must be pitched for proper drainage. • TFP530 Page 4 of 8 K-factor K-factor, r -1 Length, GPM/psi% I Inches(mm) (LPM/bar'=) SPRINKLER FITTING 2-1/2 to 6-1/4 11.2 FACE OF (REFER TO DESIGN SPRINKLER I I CRITERIA SECTION) (63 mm to 159 mm) (161,3) FITTING 6-1/2 to 10-1/2 11.1 (165 mm to 267 mm) (159,8) ORDER LENGTHS: 3-5/8"DIA. 10-3/4 to 14-3/4 11.0 3"to 48" (92,1 mm) (273 mm to 375 mm) (158,4) (76,2 to 1219,2 mm) I I IN 1/4"(6,4 mm) 2-3/4"DIA. 15 to 18-3/4 10.9 INCREMENTS ~(69,9 mm) ' (381 mm to 476 mm) (157,0) 19 to 23 10.8 (483 mm to 584 mm) (155,5) FACE OF 23-1/4 to 26-3/4 10.7 CEILING (591 mm to 679 mm) (154,1) %� I. 27-1/4 to 31-1/4 10.6 (692 mm to 794 mm) (152,6) 2-1/4±1/8"* 31-1/2 to 35-1/4 10.5 (800mmto695mm) (151,2 (57,2±3,2 mm) 1ini *ESCUTCHEON ) '■/ WILL PERMIT 35-1/2 to 39-1/2 10.4 ±1/4"(6,4 mm)ADJUSTMENT (902 mm to 1003 mm) (149,8) .__�._. 39-3/4 to 43-1/2 10.3 FIGURE 2 (1010mm to 1105 mm) (148,3) SERIES DS-2 DRY-TYPE PENDENT WITH FLUSH ESCUTCHEON 43-3/4 to 48 10.2 STANDARD RESPONSE(TY5255)OR QUICK RESPONSE(TY5235) (1111 mm to 1219 mm) (146,9) Notes: K-factor Length is determined as follows: (� • Flush:Order Length from Figure 2 plus 1/2 in. 1 I (12,7 mm) ' `- -� • Recessed:Order Length from Figure 3 plus 1/4 SPRINKLER FITTING in.(6,3 mm) • Fd:Order Length front Figure 4 plus 3-1/4 FACE OF (REFER TO DESIGN in..(82,6(82,6 mm) SPRINKLER I CRITERIA SECTION) • Without Escutcheon:Order Length from Figure 5 FITTING minus 2-1/4 in.(57,2 mm) TABLE C ORDER LENGTHS: 3-5/8"DIA. DISCHARGE COEFFICIENTS 3-1/2"to 48" (92,1 mm) (88,9 to 1219,2 mm) I I IN 1/4"(6,4 mm) f 2-3/4"DIA. INCREMENTS (69,9 mm)— FACE OF ■ CEILING * �en *ESCUTCHEON 1 5 WILL PERMIT (41,3±3,21 mm) /.t■'Ns ±3/8"(9,5 mm) 1 ._.�._. ADJUSTMENT FIGURE 3 SERIES DS-2 DRY-TYPE PENDENT WITH RECESSED ESCUTCHEON STANDARD RESPONSE(TY5255)OR QUICK RESPONSE(TY5235) TFP53O Page 5 of 8 I -'� SPRINKLER FITTING . SPRINKLER FACE OF (REFER TO DESIGN WRENCHING ORDER LENGTHS: SPRINKLER I I CRITERIA SECTION) AREA 1"to 45-1/4" FITTING 3-5/8"DIA. (25,4 to 1149,4 mm) (92,1 mm) WRENCH RECESS INCREMENTS FACE OF I- 2-3/4"DIA. All �O CEILING I (69,9 mm)1 ilt• ■� I -%� I\1`II PUSH WRENCH I�� INTO ENSURE FOR ORDER LENGTHSI ENGAGEMENT <3-1/4"(82,6 mm): W*ESCUTCHEON WITH SPRINKLER �� 4-7/8±1/8"(123,8±3,2 mm)* WILL PERMIT WRENCHING AREA -or- ±5/8"(15,9 mm) FIGURE 6 FOR ORDER LENGTHS ADJUSTMENT W-TYPE 17 >_3-1/4"(82,6 mm): SPRINKLER WRENCH 5-5/8±1/8"(142,9±3,2 mm)** ** ESCUTCHEON / W. WILL PERMIT ±1-3/8"(34,9 mm) � _ ADJUSTMENT FIGURE 4 SERIES DS-2 DRY-TYPE PENDENT WITH EXTENDED ESCUTCHEON cS \ STANDARD RESPONSE(TY5255)OR QUICK RESPONSE(TY5235) I MI I SPRINKLER FITTING ' � FACE OF (REFER TO DESIGN ��I'l SPRINKLER CRITERIA SECTION) G FITTING Elf DO NOT FIGURE 7 ORDER LENGTHS: DO NOT GRASP DEFLECTOR 5"to 48" (127,0 to 1219,2 mm) IN 1/4"(6,4 mm) INCREMENTS 1 MINIMUM 2-1/4"(57,2 mm) DEFLECTOR TO CEILING FIGURE 5 SERIES DS-2 DRY-TYPE PENDENT WITHOUT ESCUTCHEON STANDARD RESPONSE(TY5255) OR QUICK RESPONSE(TY5235) TFP53O Page 6 of 8 eon Plate by under or over-tightening TO WET i SIDE FACE OF the sprinkler. Re-adjust the position of the sprinkler fitting to suit. SYSTEM OUTLET SPRINKLER PLUGGED FITTING Note:Install pendent sprinklers only in the pendent position. The Deflector of HEATED BIB EXPOSURE a pendent sprinkler must be parallel to AREA HEATED LENGTH the ceiling. AREA (SEE DESIGN Step 1. With a non-hardening pipe- SPRINKLER CRITERIA thread sealant such as TEFLON applied DSB-2 , FITTING DSB-2 SECTION) to the Inlet threads, hand-tighten the BOOT (SEE DESIGN BOOT sprinkler into the sprinkler fitting. Do CRITERIA not grasp the sprinkler by the Deflec- SECTION) tor,see Figure 7. EctStep 2. Wrench-tighten the sprinkler using either: • a pipe wrench on the Inlet Band or the Casing,see Figure 1 c • the W-Type 17 Sprinkler Wrench on FIGURE 8 FIGURE 10 the Wrench Flat,see Figure 2 SPRINKLER FITTING EXPOSURE LENGTH HEATED AREA Apply the Wrench Recess of the W-Type 17 Sprinkler Wrench to the STRAP TIES Wrench Flat. _ RUN . (ENDS ON O�_ OUTLET OPPOSING Note: If sprinkler removal becomes —PLUGGED SIDES OF necessary, remove the sprinkler using BOOT) the same wrenching method noted SPRINKLER above.Sprinkler removal is easier when TO DRY FITTING — DSB-2 BOOT a non-hardening sealant was used SYSTEM (SEE DESIGN ADHESIVE and torque guidelines were followed. CRITERIA After removal,inspect the sprinkler for AREA SECTION) 2(-3/4"DIA. damage. r � ( (69,9Step 3.After installing the ceiling and SUBJECT CETO DSB-2 III HOLE applying a ceiling finish, slide on the FREEZING BOOT outer piece of the escutcheon until INSULATEDit comes in contact with the ceiling. FREERDo not lift the ceiling panel out of its 7777 y _ STRUCTURE 51normal position. 1e 1 I DS-2 When using the Deep Escutcheon, SHOWN hold the outer piece in contact with the WITH FLUSH mounting surface(ceiling or wall).Then ...O ESCUTCHEON rotate the inner piece approximately 1/4 FIGURE 9 FIGURE 11 turn with respect to the outer piece, SPRINKLER FITTING MODEL DSB-2 DRY SPRINKLER to hold the Deep Escutcheon firmly UNHEATED AREA BOOT WITH SERIES DS-2 together. DRY-TYPE PENDENT SPRINKLER Care and Installation Do not install any bulb-type sprinkler Maintenance TYCO Series DS-2 Dry-Type Sprinklers, if the bulb is cracked or there is a loss 11.2K Pendent, Standard (5 mm bulb) of liquid from the bulb. With the sprin- TYCO Series DS-2 Dry-Type Sprin- and Quick Response(3 mm bulb),and kler held horizontally,a small air bubble klers, 11.2K Pendent, Standard (5 mm Standard Coverage must be installed in should be present.The diameter of the bulb)and Quick Response(3 mm bulb), accordance with this section. air bubble is approximately 1/16 in. and Standard Coverage must be main- General Instructions (1,6 mm)for the 135 F(57 C)rating to tained and serviced in accordance with Series DS-2 Dry Type Sprinklers must 1/8 in. (3,2 mm) for the 360°F(182°C) this section. only be installed in fittings that meet rating. the requirements of the Design Cri- A leak-tight 1 in. NPT sprinkler joint Before closing afire protection system teria section. See the Design Criteria should be obtained by applying a min- main control valve for maintenance section for other important require- imum-to-maximum torque of 20 to work on the fire protection system ments regarding piping design and 30 lb-ft (26,8 to 40,2 N•m). Higher that it controls, obtain permission to sealing of the clearance space around levels of torque may distort the sprin- shut down the affected fire protection the sprinkler Casing. With reference kler Inlet with consequent leakage or systems from the proper authorities to Figure 7, do not grasp the sprinkler impairment of the sprinkler. and notify all personnel who may be by the Deflector. Failure to follow this affected by this action. instruction may impair performance of Do not attempt to compensate for Absence of the outer piece of an the device. insufficient adjustment in an Escutch- escutcheon, which is used to cover a • TFP530 Page 7 of 8 clearance hole, may delay the time to Limited Ordering sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat Warranty Procedure (Figure 1)to indicate if the Dry Sprinkler is remaining dry. Evidence of leakage For warranty terms and conditions,visit Contact your local distributor for from the Vent Hole indicates potential www.tyco-fire.com. availability. When placing an order, leakage past the Inlet seal and the need indicate the full product name and part to remove the sprinkler to determine number(P/N). the cause of leakage(e.g.,an improper installation or an ice plug). Close the Dry-Type Sprinkler fire protection system control valve and When ordering Series DS-2 Dry Type drain the system before removing the Sprinklers, 11.2K Pendent,Standard(5 sprinkler. mm bulb) and Quick Response(3 mm bulb),and Standard Coverage,specify Sprinklers which are found to be the following information: leaking or exhibiting visible signs of corrosion must be replaced. • SIN: TY5255-Standard Response Automatic sprinklers must never be TY5235-Quick Response painted, plated, coated, or other- • Order Length: wise altered after leaving the factory. Dry-Type S rinklers are furnished Modified sprinklers must be replaced. p Sprinklers that have been exposed to based upon Order Length as corrosive products of combustion, but measured from the face of the have not operated,should be replaced ceiling to the face of the sprinkler if they cannot be completely cleaned fitting see Figures 2 through 5.After by wiping the sprinkler with a cloth or the measurement is taken, round it by brushing it with a soft bristle brush. to the nearest 1/4 in. increment. • Inlet Connections: Care must be exercised to avoid 1 in. NPT damage to the sprinklers - before, (Standard) during, and after installation. Sprin- klers damaged by dropping, striking, ISO 7-R 1 wrench twist/slippage,or the like,must (For information on ISO Inlet Thread be replaced. Also, replace any sprin- Connections,contact your Johnson kler that has a cracked bulb or that has Controls Sales Representative.) lost liquid from its bulb,see Installation • Temperature Rating Section. The owner is responsible for the • Sprinkler Finish inspection,testing,and maintenance of • Escutcheon Type and Finish, as their fire protection system and devices applicable in compliance with this document, as • Part Number from Table D well as with the applicable standards of the NATIONAL FIRE PROTECTION Replacement Escutcheons ASSOCIATION, such as NFPA 25, in Order replacement escutcheons addition to the standards of any other separately. authorities having jurisdiction.Contact Specify:(specify type),(specify)finish, the installing contractor or product P/N(specify): manufacturer with any questions. Flush and Recessed Automatic sprinkler systems are rec- White Color 854902 ommended to be inspected, tested, Chrome Plated 854912 and maintained by a qualified Inspec- Brass Plated 854922 tion Service in accordance with local Deep requirements and/or national codes. White Color 854802 Chrome Plated 854812 Brass Plated 854822 Sprinkler Wrench Specify W-Type 17 Sprinkler Wrench, P/N 56-010-4-118 Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This Part Number includes one (1) Boot, two (2) Strap Ties, and 1/3 oz of Adhesive (a quantity sufficient for installing one boot). TFP530 Page 8 of 8 P/NE 61 — XXX — X — XXX I ORDER LENGTH2 SIN SPRINKLER ESCUTCHEON 055 5.50 in. FINISH FINISH1 10 Standard Response Pendent TY5255 0 CHROME SIGNAL WHITE 082 8.25 in. with Flush Escutcheon (Figure 2) PLATED (RAL9003) • 11 Standard Response Pendent TY5255 1 NATURAL SIGNAL WHITE 180 18.00 in. with Recessed Escutcheon (Figure 3) BRASS (RAL9003) • 12 Standard Response Pendent TY5255 q SIGNAL WHITE SIGNAL WHITE 187 18.75 in. with Extended Escutcheon (Figure 4) (RAL9003) (RAL9003) 13 Standard Response Pendent TY5255 5 NATURAL BRASS 372 37.25 in. without Escutcheon (Figure 5) BRASS PLATED y CHROME CHROME 480 48.00 in. PLATED PLATED 30 Quick Response Pendent TY5235 with Flush Escutcheon (Figure 2) TEMPERATURE Quick Response Pendent TY5235 RATING 31 with Recessed Escutcheon (Figure 3) 0 135°F(57°C) 32 Quick Response Pendent TY5235 with Extended Escutcheon (Figure 4) Quick Response Pendent TY5235 1 155°F(68°C) 35 without Escutcheon (Figure 5) 2 175°F(79°C) Notes: 1. Escutcheon Finish applies to sprinklers with escutcheons. 3 200°F(93°C) 2. Dry-Type Sprinklers are furnished based upon"Order Length"as measured per Figures 2 through 5,as applicable,end for each individual sprinkler where it is to be installed.After the measurement Is taken, round it to the nearest 1/4 inch increment. 141°C Use Prefix"I"for ISO 7-R1 Connection(e.g.,I-61-101-1-180). 4 286°F(141°C) TABLE D SERIES DS-2 STANDARD AND QUICK RESPONSE, STANDARD COVERAGE, DRY-TYPE SPRINKLERS PART NUMBER SELECTION • 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 C 205 Johnson Controls.All rights reserved.All specifications and other Information Mown were current as of document revision date and are subject to donee without notice. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPAarr registered va°emaAs of National Flee Protection Association, TEFLON is atred at M Controls ameda The C mours Company FC.LLC • CEI Worldwide I www.tyco-fire.com NContacts TFP53O Change History Appendix ISSUE DATE NOTES 09-21 Added Replacement Escutcheons to Ordering Procedure. 11-19 Removed consulting Technical Services Department statement from Sprinkler Fittings subsection Notice. Updated Tyco®branding and document format;Added Johnson Controls copyright;Added disclaimer 08-18 stating specifications and information subject to change without notice;Added reference to Regulatory and Health Warning Technical Data Sheet TFP2300. 01-14 Removed note from Table D Part Number Selection limiting sprinklers having 286°F(141°C)temperature rating to non-recessed assemblies only. 06-13 Clarified Sprinkler with Extended Escutcheon order length specification to lengths greater than 3-1/4a (82.6 mm),formerly lengths equaling 3-1/4" (82.6 mm); Updated and standardized RAL color finishes. 05-11 Clarified NYC Approved;Updated minimum order and exposed barrel lengths;Improved Design Criteria section;Updated patent information. Added Model DSB-2 Dry Sprinkler Boot;Added NFPA 13 requirements for use of DSB-2;Added illus- 12-07 trations providing guidance on alternative piping connections to dry type sprinklers for freeze protection or system drainage;Added Natural Brass sprinkler with Brass plate escutcheon finish option. 07-04 Clarified sprinkler is not to be installed by grasping deflector. 04-04 Added reference to Installer Warning data sheet TFP700;Added NYC Approved;Added guidance on use of compatible CPVC fittings. 01-03 Added new Tyco Fire&Building Products masthead. 02-02 New Technical Data Sheet for Series DS-2 Dry Type Standard Coverage Pendent Sprinklers. 1467 Elmwood Avenue,Cranston,RI 029101 Telephone+1-401-781-8220 Johnson 44(� C 2022 Johnson controls.All rights reserved.All speclficatione and other Information shown were current as of document revlsion date and are subject to change without notice. Controls f/it if 41P } r 2-pc Adjustable :s t Sprinkler Escutcheon F Description The two-piece adjustable sprinkler escutcheon (canopy) has Specifications been designed to provide an aesthetically pleasing concealment of the sprinkler piping, servicing the individual sprinkler head. Type: 2-pc Adjustable w/ weep hole The sprinkler escutcheon (canopy) has a full 2" of field adjust Standard threads: ment, making it possible to accommodate minor irregularities in 1/2"or 3/4" IPS ceiling to sprinkler head location. This assures complete conceal- ment of the ceiling penetration allowing only the sprinkler to be Material: exposed. Additionally the skirt is manufactured with two raised .020"cold rolled steel reliefs allowing for increased friction between the two parts when installed. This sprinkler escutcheon (canopy) is available in two Standard finishes: standard thread sizes and four standard finishes. Special threads Chrome Brass (openings) and finishes are available. White Off white Installation Proper installation of the sprin- install the sprinkler into the Depth: kler escutcheon can be ac- reducing coupling using the Min. 2" complished with tools ordinar- manufacturers sprinkler instal- Max. 3" ily found on the job site. The lation instructions. After the fin- Base coverage: installer must make sure that ished ceiling is installed, push 3.5" the reducing coupling on the the skirt over the cup so that drop nipple does not exceed it is flush against the ceiling. 2" outside diameter. The face Upon system activation, leaks of the coupling must extend at can be detected by observing least 1.85" but not more than accumulation of moisture at the 2.85" past the finished ceil- "weep" hole. ing. Turn the escutcheon cup onto the sprinkler threads then Fire Protection Products, Inc 6241 Yarrow Dr..Suite A, Carlsbad,CA 92011-1541 ©1989-2008 Fire Protection Products,Inc(FPPI) F„e P„„P,,, For questions. 1 800 344-1822•1 800 344-3775 fax•www.fppi.corn • Recessed Canopy Coverage Extension Description Recessed Canopy Coverage Extensions provider increased cov- Specifications erage of the recessed canopy flange against the ceiling or wall material where it is installed. The primary purpose is to allow for Material: increased distance between the finished surface .020"cold rolled steel of the building interior and the recessed sprinkler assembly. AHJ's within certain earthquake zones require a minimum of Standard finishes: Chrome 1" space between the sprinkler or sprinkler drop and the material White it penetrates. Can also be used to provide coverage for over- sized holes cut in finish material from previous sprinkler place- Coverage: ments. Fits most existing recess sprinkler canopies and is corn- 4" or 5"x 1 15/16" ID patible with all FPPI Recessed Canopy's. Item Numbers: Installation 01-490 4" Coverage Chrome No tools are required for the sprinkler penetrates with 01-491 5"Coverage Chrome installation of the Recessed out causing the interior sur- 01-492 4"Coverage White Canopy Coverage Extension. face to be moved or lifted by 01-493 5"Coverage White Simply slide the recessed the recessed skirt/coverage escutcheon skirt through the extension. Follow sprinkler ID of the coverage extension manufacturers instructions then install or re-install the regarding the installation of recessed escutcheon skirt on sprinklers in recessed appli- to the retainer. Press the re- cations. May be used either cessed skirt firmly into place horizontally or vertically. against the interior surface ` - Fire Protection Products, Inc 6241 Yarrow Dr.,Suite A, Carlsbad. CA 92011-1541 „©2006-2007 Fire Protection Products,Inc(FPPI) F„o P„ P,„I. For questions: 1 800 344-1822•1 800 344-3775 fax•www.fppi.com