Permit Support Document (41) OFFICE COPY • + W YAT T FIRE PROTECTION , INC. 9095 S.W. Burnham Tigard, OR 97223 NW REGENERATIVE ORTHOPEDICS 16250 SW UPPER BOONES FERRY RD PORTLAND, OR 97224 PLEASE PROVIDE OPf ICE COPY COMPLETED NFPA 13 CITY OF TIGARII .r MATERIAL AND TEST REVIEWED FOR CODE COMPLIANCE CERTIFICATE AT Appmvcd• FINAL INSPECTION OTC: I l VALIDITY OF PERMIT PcrmIt#: Fps,yp 13- o 1 Q R 3 • THE ISSUANCE of A PERMIT Address: �� -� �, BASED ON CONSTRUCTION • I SSE Q l r 0: G DOCUMENTS AND OTHER Suite#: _30%0 _._ DATA SHALL NOT PREVENT By: ---y ) ` Date: j' '7_s THE CODE OFFICIAL FROM I REQUIRING THE CORRECTION OF ERRORS. OSSC Ins n FIRE PROTECTION EQUIPMENT SUBMITTAL PROVIDE EITHER FLEXIBLE SPRINKLER HEAD OR 2-INCH OVERSIZE RINGS OR. INTERP 10-01 tco. Worldwide www.tyco-fire.com Contacts Series TY-B, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage IMPORTANT The recessed version of the Series TY-B Pendent Sprinkler,where applica- - Refer to Technical Data Sheet ble, is intended for use in areas with a TFP2300 for warnings pertaining to finished ceiling.This recessed pendent t ` --- regulatory and health information. sprinkler uses one of the following: .> Always refer to Technical Data , Y A two-piece Style 15 Recessed � o Sheet TFP700 for the "INSTALLER Escutcheon with recessed adjust- , WARNING" that provides cautions ment up to 5/8 in.(15,9 mm)from the with respect to handling and instal- flush pendent position. AIM I lation of sprinkler systems and corn- ponents. Improper handling and • A two-piece Style 20 Recessed j installation can permanently damage Escutcheon with recessed adjust- -m--ipldr ;'} p ment u to 1/2 in.(12,7 mm from the "— 4-...,---.. a sprinkler system or its compo- P ) nents and cause the sprinkler to fail flush pendent position. to operate in a fire situation or cause The adjustment provided by the it to operate prematurely. Recessed Escutcheon reduces the accuracy to which the fixed pipe drops s Scan the OR code or enter the URL to the sprinklers must be cut. ate. } in a web browser to access the most Intermediate level versions of Series up-to-date electronic version of this TY-B Sprinklers are described in Tech- ; document. Data rates may apply. nical Data Sheet TFP352. Sprinkler guards and shields are described in . -, 0 7 1• • Technical Data Sheet TFP780. i „ t. '• NOTICE J The Series TY-B Sprinklers described " A' " I. } herein must be installed and main- ■ • tained in compliance with this docu- fment, as well as with the applicable Maximum Working Pressure „ standards of the National Fire Protec- 175 psi(12.1 bar) • r 25L3 psI(17 tion Association,in addition to the ., k,J The maximum workin ressure of 250 si 17.2 bar) 0 dards of any otheraUfhorities h.aaV only applies totltets ,fir i , toporafo- El c ■1 Jurisdiction.Failure tb•clo so may frfi ra ies,Inc.(UL). the performance of these devices. Discharge Cteffititry«''',,1 docs.jci.com/tycofire/tfp152 The owner is responsible for main- K=5.6 GPM/pfi'i=(80,6 Llitlpfiril taming their fire protection system and devices in proper operating con- Temperature Ratings r, General dition. Contact thaJrastalling contras SeeTableA «ii t • tor or product manufacturer with any Finishes .A, , Description qSprinkler :,, questions. S rinkler:SeeTa6'le B • The TYCO Series TY-B, 5.6 K-factor, Recessed Escutcheon:White Coated, Upright (TY315) and Pendent(TY325) Plated "` I Sprinkler Black Coated,Chrome Plated:OF brass Sprinklers described in this data sheet Identification are standard response, standard cov- Physical Characteristics erage, decorative 5 mm glass bulb Frame Bronze type spray sprinklers designed for use Numbers ( /Ns Button Brass/Copper in light,ordinary,or extra hazard,corn- TY315. . . . Upright 5.6K, 1/2 in. NPT Sealing Assembly...Stainless Steel w/TEFLON mercial occupancies such as banks, colt ronze 325nze hotels,shopping malls,factories, refin- TY325. . Pendent 5.6K, 1/2 in. NPT Compression Screw tor BBronze eries,and chemical plants. Technical Data - :rf a,, . ApprovalsF.:'.!':".;, .' t , ,.a..(1 f - See Table A - - '.`'' } } t.i.) kfr1,,,. Page 1 of 4 SEPTEMBER 2022 :; P152 TFP152 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 5 - 7/16" Ellt.-- -- --.. / — (11,1 mm) �iir„ 4 NOMINAL 2" ( h MAKE-IN (50,8 mm) 2any 2" ��V 1 3/8" ��� 3 (50,8 mm) (34,9 mm) WRENCH FLATS 1 1/2" NPT** DEFLECTOR* — 2-7/8"(73,0 mm)DIA. — CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-B UPRIGHT(TY315)AND PENDENT(TY325)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, STANDARD RESPONSE Es Design the sprinkler. Readjust the position of the sprinkler fitting to suit. Criteria Upright and Pendent Sprinklers WRENCH RECESS The Series TY-B Upright and Pendent .....y"..°/ (USE ONLY The TYCO Series TY-B, 5.6 K-factor, Sprinklers must be installed in accor- END"A") Upright (TY315) and Pendent (TY325) dance with the following instructions. Sprinklers are intended for fire protec- tion systems designed in accordance Step 1.Install pendent sprinklers in the FIGURE 2 with the standard installation rules pendent position; install upright sprin- W-TYPE 6 recognized by the applicable Listing or klers in the upright position. SPRINKLER WRENCH Approval agency. For example,the UL Step 2. With pipe-thread sealant Listing is based on the requirements applied to the pipe threads, hand- WRENCH of NFPA 13, and the FM Approval is tighten the sprinkler into the sprinkler RECESS based on the requirements of the FM fitting. Loss Prevention Data Sheets.Only the Step 3. Tighten the sprinkler into the Style 15 or Style 20 Recessed Escutch- sprinkler fittingonlythe e �f eon, as applicable, is to be used for using W-Type pendent installations.ill! t 6 Sprinkler Wrench as shown in Figure 2.Apply the W-Type 6 Sprinkler Wrench to the wrench flats as shown in Figure Installation 1.Torque the sprinklers 7 to 14 lb-ft(9,5 The TYCO Series TY-B, 5.6 K-factor, to 19,0 N•m). lz..�`� Upright (TY315) and Pendent (TY325) Recessed Pendent Sprinklers PUSH WRENCH Sprinklers must be installed in accor- The Series TY-B Recessed Pendent IN TO ENSURE dance with this section. Sprinklers must be installed in accor- ENGAGEMENT dance with the following instructions. WITH SPRINKLER General Instructions WRENCHING AREA Do not install any bulb type sprinkler Step A. After installing the Style 15 or FIGURE 3 if the bulb is cracked or there is a loss Style 20 Mounting Plate, as applica- W-TYPE 7 RECESSED of liquid from the bulb. With the sprin- ble,over the sprinkler threads and with SPRINKLER WRENCH kler held horizontally,a small air bubble pipe-thread sealant applied to the pipe should be present.The diameter of the threads,hand-tighten the sprinkler into air bubble is approximately 1/16 in. the sprinkler fitting. Operation (1,6 mm)for the 135°F(57°C)to 3/32 in. Step B. Tighten the sprinkler into the (2,4 mm)for the 360°F(182°C)tempera- sprinkler fitting using only the W-Type 7 The glass bulb contains a fluid which ture ratings. Recessed Sprinkler Wrench(Figure 3). expands when exposed to heat.When A leak-tight 1/2 in. NPT sprinkler joint Apply the W-Type 7 Recessed Sprinkler the rated temperature is reached, the should be obtained by applying a min- Wrench to the sprinkler wrench flats as fluid expands sufficiently to shatter imum-to-maximum torque of 7 to 14 shown in Figure 1.Torque the sprinklers the glass bulb, allowing the sprinkler lb-ft (9,5 to 19,0 N•m). Higher levels of 7 to 14 lb-ft(9,5 to 19,0 N-m). to activate and water to flow. torque may distort the sprinkler inlet Step C.After the ceiling is installed or and cause leakage or impairment of the finish coat is applied, slide on the the sprinkler. Style 15 or Style 20 Closure over the Do not attempt to compensate for Series TY-B Sprinkler and push the insufficient adjustment in the escutch- Closure over the Mounting Plate until eon plate by under- or over-tightening its flange contacts the ceiling. TFP152 Page 3 of 4 - Care and 2-7/8" DIA. Maintenance (73,0 mm) 2-1/4° DIA. The TYCO Series TY-B, 5.6 K-factor, FACE OF - (57,2 mm) Upright (TY315) and Pendent (TY325) SPRINKLER Sprinklers must be maintained and ser- FITTING 5/8"(15,9 mm) viced in accordance with this section. + \ FLUSH Before closing a fire protection system 3/8±5/16" main control valve for maintenance (9,5±7,9 mm) L„Z ,,,a 'r % !r work on the fire protection system f - ' that it controls, obtain permission to / �-� 1/8. J • shut down the affected fire protection MOUNTING (3,2 mm) system from the proper authorities SURFACE and notify all personnel who may be - affected by this action. CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) TY-B PLATE 3/4"(19,1 mm) Absence of the outer piece of an escutcheon, which is used to cover FIGURE4 a clearance hole, can delay sprinkler SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) operation in a fire situation. WITH TWO-PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 The owner must assure that the sprin RECESSED ESCUTCHEON klers are not used for hanging any objects and that the sprinklers are only 2-7/8" DIA. cleaned by means of gently dusting (73,0 mm) with a feather duster; otherwise, non- FACE OF operation in the event of a fire or road- SPRINKLER 2-1/4" DIA. vertent operation may result. FITTING (57,2 mm) Sprinklers which are found to be 5/16±1/4" leaking or exhibiting visible signs of 9±6,4 mm) 1/2"(12,7 mm) �'corrosion must be replaced. y - FLUSH Automatic sprinklers must never be =1 I ,7 +_i_ painted, plated, coated, or other- wise altered after leaving the factory. f / �� Modified sprinklers must be replaced. MOUNTING 1/8 J Sprinklers that have been exposed to SURFACE ��� (3,2 mm) corrosive products of combustion, but have not operated,should be replaced if they cannot be completely cleaned CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) by wiping the sprinkler with a cloth or TY-B PLATE 7/8°(22,2 mm) by brushing it with a soft bristle brush. FIGURE 5 Care must be exercised to avoid SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY(TY325) damage to the sprinklers before, WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 i during, and after installation. Sprin- RECESSED ESCUTCHEON klers damaged by dropping, striking, wrench twist/slippage,or the like,must Automatic sprinklers are recommended Sprinkler Assemblies with NPT be replaced. Also, replace any sprin- to be inspected,tested,and maintained Thread Connections kler that has a cracked bulb or that has by a qualified Inspection Service in Specify: Series TY-B Upright or lost liquid from its bulb. See Installa- accordance with local requirements Pendent (specify) Sprinkler, SIN tion Section. and/or national codes. (specify), K=5.6, Standard Response, Thereafter, annual inspections based IN (specify) temperature rating, (specify) on NFPA 25 are required; however, Linvted finish, P/N (specify, refer to Table B) ' instead of inspecting from the floor Recessed Escutcheon level, a random sampling of close-up Warranty Specify: Style 15 Recessed Escutch- visual inspections should be made. eon with(specify*)finish,P/N(specify*) The owner is for For warranty terms and conditions,visit The town testing,and responsibleenance the www.tyco-fire.com. Specify: Style 20 Recessed Escutch- Peon with(specify*)finish, P/N(specify') their fire protection system and devices Ordering compliance with this document, as Or g 'Refer to Technical Data Sheet TFP77D well as with the applicable standards procedure Sprinkler Wrench of the National Fire Protection Associ- Specify: W-Type 6 Sprinkler Wrench, ation such as NFPA 25, in addition to Contact your local distributor for avail- P/N 56-000-6-387 the havingstandarjurisdi of any other autthe install-nsies ability.When placing an order,indicate Specify: W-Type 7 Sprinkler Wrench, jurisdiction.Contact the the full product name and Part Number P/N 56-850-4-001 ing contractor or product manufacturer (P/N) with any questions. • TFP152 Page 4 of 4 Sprinkler Temperature Bulb Sprinkler Finish8 K-factor Liquid Type Rating Color Natural Chrome Polyester** Brass Plated 135'F(57°C) Orange Upright °°155F(68C (TY315) (68°C) Red and 175°F(79°C) Yellow Pendent 1,2,3,4,5,6,7 (TY325) 200°F(93°C) Green 5.6 Figure 1 286°F(141°C) Blue 1/2 in. 360°F(182°C) Mauve NPT 135°F(57°C) Orange Recessed 155°F(68°C) Red Pendent 1,2,3,4,7 (TY325)* 175°F(79°C) Yellow Figures 4 and 5 200°F(93°C) Green 286°F(141°C) Blue 1,2,7 NOTES: 1. Listed by Underwriters Laboratories,Inc.(UL) 2. Listed by Underwriters Laboratories,Inc.for use in Canada(C-UL) 3. Approved by FM Global(FM Approvals) 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/03) 5. VdS Approved(For details contact Johnson Controls,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377) 6. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/05) 7. EAC Approved 8. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers_ ' Installed with Style 15(1/2 in.NPT)5/8 in.Total Adjustment Recessed Escutcheon,as applicable Frame and deflector only N/A—Nat Applicable TABLE A SERIES TY-8 UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS P/N* 77 — XXX — X — XXX I i SIN SPRINKLER TEMPERATURE FINISH RATINGS 570 5.6K UPRIGHT(1/2 in.NPT) TY315 1 NATURAL BRASS 135 135°F(57°C) 571 5.6K PENDENT(1/2 in.NPT) TY325 3 PURE WHITE(RAL9010)'* 155 155°F(68°C) POLYESTER 4 SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER 5 JET BLACK(RAL9005) 200 200°F(93°C) POLYSTER 9 CHROME PLATED 286 286°F(141°C) 360 360°F(182°C) ' Use suffix"I"for ISO 7-1 connection;for example,77-570-4-175-I ^` Eastern Hemisphere sales only 000 OPEN"* "'OPEN indicates sprinkler assembly without Glass Bulb,Button,and Sealing Assembly TABLE B SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 1467 Elmwood Avenue,Cranston,RI 029101 Telephone+1-401-781-8220 02022 Johnson Controls.All rights reservod.All specifications end other information shown were current as of document revision date and are subject to change without notice. Johnson a��I NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are reaialered trademarks of Nall°ozl Fife Proleclion Asauclaliu, Con 4 r o l s TEFLON is trademark t The Chem°urs Company FC,LLC 11 Fire Sprinkler Pipe Schedule 10 and Schedule 40 Submittal Data Sheet FM Approved and Fully Listed Sprinkler Pipe SCHEDULE 10 SPECIFICATIONS Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL C-UL and FM Listed. NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm In. mm In. mm lbs./ft. kg/m CRR" Lift Approvals and Specifications Both products meet or exceed 11/4 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7,3 61 the following standards: 17S 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 • ASTM A135,Type E, Grade A(Schedule 10) 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 • ASTM A795,Type E, Grade A(Schedule 40) 2% 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 • NFPA13 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected 4 4.500 na.3 4.260 108.2 120 3.05 5.62 8.37 1.6 19 to the toughest possible testing protocols to 5 5.563 141.3 5.295 134.5 .134 340 7.78 11.58 1.5 13 ensure the highest quality and long-lasting performance. 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8,625 219.1 8.249 209.5 188 4.78 16.96 25.26 2.1 7 Finishes and Coatings All Wheatland black steel fire sprinkler pipe "Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. -The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. up to 6" receives a proprietary mill coating to Threaded Schedule 40 steel pipe Is used as the benchmark(value of 1.0). ensure a clean,corrosion-resistant surface that outperforms and outlasts standard lacquer - coatings.This coating allows the pipe to be SCHEDULE 40 SPECIFICATIONS easily painted,without special preparation. Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL black,or with hot-dip galvanizing,to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES - FM/UL requirements for dry systems that meet In. mm In. mm in. mm lbs./ft. kg/m CRR' Lift the zinc coating specifications of ASTM A795 or A53.All Wheatland galvanized material is 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 also UL Listed. 13/4 1.660 42.2 1.380 35.1 .140 3.56 227 3.39 1.00 51 Product Marking 1% 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 Each length of Wheatland fire sprinkler pipe is continuously stenciled to show 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 the manufacturer,type of pipe,grade,size •Calculated using Standard UL CRR formula,UL Fire Protection Directory,Category VIZY. and length.Barcoding is acceptable as a " The CRR Is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark(value of 1.0). supplementary identification method. OC ® APPROVED SUBMITTAL INFORMATION PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: ❑ BLACK ❑ HOT-DIP GALVANIZED Wheatland Tube 700 South Dock Street Sharon, PA 16146 Wheatland Tube P 800.257.8182 1 F 724.346.7260 1 info@wheatland.com I wheatland.com JMC STEEL GROUP Ductile Iron Threaded Fittings 44)/ �'• 7i ii SMITL _ CGOPER INTERNATIONAL Ductile Iron Threaded Fittings Specifications • < - branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 WSP C el US • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 11:* • Fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &physical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Working Pressure, Nonshock psiG Degrees F 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 ' _ 1 ucti a ron ittings- ass I I I ' � ,..1;,r t�1� C ® US 41114> APPROVED A Fig. 35E 3- 90°Elbow LISTED Size Part Number A Packing Weight n in Inner Master Ib _4 /2 35E3004 1.13 '00 200 . II �� 3/4 35E 3006 1.31 70 140 0.3 A 35E3010 1.50 40 80 0.5 0.8 1-114 35E 3012 1.75 25 50 2 0 1-1/2 35F 3014 194 18 36 1.1 2 35E 3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 32 Fig. 35RE3- 90°Reducing Elbow B ' Size Part Number A B Packing Weight in in Inner Master lb ant I 3/4 x 1/2 358E3006004 20 22 80 160 0.3 ,y 1 x 1/2 35RE3010004 1.26 1.36 140 0.4 'i in 1 x 3/4 35RE3010006 138 1.45 50 70 100 0.4 a' A 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1 1/4 x 3/4 35RE3012006 1.45 1.6 3 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 351-3E3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1,75 25 50 0.7 1-1/2x 1 35RE3014010 1.65 1,80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RF3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 202 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1_5 2-1/2 x 1-1/2 35RE3024014 2.16 2,51 6 12 2.2 2-1/2 x 2 358E3024020 2.39 2,60 6 12 2.5 Fig. 35F 3-45° Elbow Size Part Number A Packing Weight �A in in Inner Master lb 1/2 35F 3004 0 88 150 300 0.2 tk 3/4 35F 3006 0.98 80 160 0.3 1 35E 3010 1.13 40 80 0.5 1-1/4 35F3012 1.29 25 50 0.7 En IA 1-1/2 35F 3014 1 44 20 40 1.0 2 35F 3020 1.69 10 20 1.6 1 2-1/2 35F 3024 1.95 a 8 2.7 Fig. 35T 3- Tee Size part Number A Packing Weight in in Inner Master lb 'iin A 1/2 35T3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 I III 1 35T 3010 1.50 25 50 0.7 1-1/4 35T 3012 1.75 10 20 1.1 1-1/2 35T3014 1.94 '0 20 1.5 A da A 2 35T 3020 2.25 6 12 2.4 2-1/2 351 3C24 2.70 4 8 4.3 111 S\II'I'II-(;OOPF..R I\1'RRN,WON\I-'' • TO1,I, FREE 1-800-766-0076 • FAX 343) 890-1-156 • uwv,.smithcooper.com •-�� 4`'' Ductile Iron Fittings - Class 300 UL/FM c ® us APPROVED Fig. 35RT3-Reducing Tee LISTED Size Part Number A B C Packing Weight in in in in Inner Master lb C 3/4 x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0,4 1 x 1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 a _ 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1 x 3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 B 1 x 3/4 x 3/4 35R13010006006 1.38 1.31 1.45 35 70 0.6 A 1 x 3/4 x 1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4 x 1/2 x 1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4 x 3/4 35R13012006 1.45 1.45 1.62 15 30 0.9 1-1/4 x 3/4 x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4 x 1 3513T3012010 1.58 1.58 '.67 15 30 1.0 1-1/4 x 1 x 1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4 x 1 x 3/4 35RT30120'.0006 1.45 1.38 1.63 20 40 0.8 1-1/4 x 1 x 1 35RT3012010010 1.58 1,50 1.69 20 40 0.9 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2 x 1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2 x 1/2 x 1-1/4 35R13014004012 1.81 1.56 1.88 24 48 1.1 1-1/2 x 1/2 x 1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1-1/2 x 3/4 35RT3014006 1 52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2 x 1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0 8 1-1/2 x 1 x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1 1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1 x 1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x 1 x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 _ 1-1/2 x 1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2 x 1-114 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-112 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.ao 16 3? 1 1 1-1/2 x 1-1/4 x 1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 356T3014012014 1.94 1.88 1.94 14 28 1.4 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 20 1.5 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2 02 2.25 8 16 1 9 2 x 1-1/4 35RT3020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 35R73020012020 2.25 2.10 2.25 8 16 2.0 2 x 1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1 88 10 20 1.3 2 x 1-1/2 x 3/4 35RT3020014006 1.60 1.52 1.97 10 20 1.4 2x 1-1/2 x 1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2 x 1-1/2 x 1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee Size A B C Packing Weight JIMM;_ lc in Part Number in in in Inner Master lb 3/4 x 1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 20 40 0.9 �y�.-.... �--� 1 x 1 1/2 35B13010014 1.80 1.80 1.65 15 30 1.0 A +i B > 1-1/4 x 1 x 1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1.2 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4 x 2 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2 10 2.02 10 20 1.8 - 1-1/2 x 2 35BT3014020 2.16 2.16 2.02 8 16 1.8 SMLITII-COOPER IN'1'ERNATIONAI." • 'L'OLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 112 'r Ductile Iron Fittings - Class 300 UL/FM ou.11,1Fri.2883 c ® us APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LISTED Size part Number A Packing Weight . .7 in in Inner Master lb 2 35C83004 38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 350P3024 300 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling Size Part Number A Packing Weight - in in Inner Master Ih A 1 x 1/2 35RC3010004 1.69 80 160 0,3 1 x 3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size Part Number A Packing Weight B in in Inner Master lb f 1 x 1/2 35H63010004 1.06 180 360 0.2 It i t 1 1 x 3/4 35HB3010006 1.06 180 360 0,1 -A 1-114 x 1 35HB3012010 1.19 90 180 0,2 1-1/2 x 1 35HB3014010 1.25 75 150 0.4 1-1/2x 1-1/4 35H133014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 351-183020012 1.38 40 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 -Square Head Plug Size part Number A Packing Weight in in Inner Master lb _Jill- - " 1/2 35SP3004 0.94 690 1200 0 07 3/4 35SP3006 1.12 350 700 0.1 III r- ) A1 35SP3010 25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP30'4 1.44 80 160 0.4 2 35SP3020 1,50 45 90 0.6 Fig. 35U 3- Union with Brass Seat A Size A Packing Weight Part Number in in Inner Master lb ' " �a 1 35U hass 3010 219 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 I �I 1-1/2 35U3014 2.62 10 20 1,7 °®��_1.r° 2 35U 3020 3.12 6 12 2.4 113 SNI1111-CooP1?R INTERN, ATION.1I1 • '1'01,1,FREE I-800-766-0076 • FAX (3231 890-436 • w o'.srnithcouper.com ,_ I ucti e ron fittings - ass I I I ' c0us APPROVED Fig. 35X 3— Cross LISTED A E AF'1 '' Size A Packing Weight MP�m1 A Part Number in in Inner Master lb mow -• 1 35X 3010 ' 50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4 �_ I �� 1-1/2 35X 3014 1.94 8 16 1.8 nIp` 2 35X 3020 2.25 6 12 2.8 I 8 B B Fig. 35RX3—Reducing Cross H H Size Part Number A B Packing Weight a.1 .. I n n nInner Master Ib ,IA 4 x 1 35RX3012010 67 58 5301.2 1-1/2x1 35RX3014010 1.80 1.65 12 24 1.4 ,I �A 2 x I 35RX3020010 2.02 1,73 8 6 2.0 near Fig. 35C 3— Cap Size part Number A Packing Weight - in in Inner Master lb I A 1/2 350 3004 0.87 300 600 0.1 3/4 350 3006 0.97 200 400 0.1 a I I 1 35C 3010 1_16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1-1/2 35C 3014 1.33 50 100 0,5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1 6 Fig. 35BC3—Beam Clamp Size A Packing Weight a �1 Part Number A in in Inner Master lb _ III ® 3/8 35BC3003 0.75 00 200 0.3 !N 111 1/2 35BC3004 0.75 80 160 0.5 ra SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 114 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS , 52 FireLock® Outlet-T C®US ® (vds] L9PCB SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating/,3/4, and 1715,20 and 25mm outlets for directly connecting sprinklers, drop nipples,sprigs,gauges,drains and other outlet products.Available for 11/4 through 76.1 mm/32 to 76.1mm piping systems,Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe.When tightened,the assembly compresses the gasket onto the OD of the pipe.The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall,Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. -Gasket: • Grade"E" EPDM-Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services up to the rated working pressure using the Grade "E"Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: • Orange enamel(North America, Latin America,Asia Pacific) • Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para_ Location Date Approved Date www.victaulic.com .ntni d.n IPS CARBON STEEL PIPE- HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 DIMENSIONS Nominal Size Hole Approx. inches/rpm Diameter Dimensions-inches/millimeters Weight Each 11" Ron XBranch +0.061+1.5 Y _Z t; FM- 0.001.0.0 1"° V W 'cv 1 Na X 1 3/16 1.30 1.83 1.10 3.87 2.56 1.0 1 32 5 _J 30.2 33.0 46.5 27.9 98.3 65.0 0.45 - v ��� 10 _ _ �\ T1 3/< ! 1 3/16 1.28 1.83 1.10 3.87 2.56 1.1 `. I 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 ,,244........• o�•r Wr ��V•����� 1 i 1 3/16 1.52 2.18 1.10 3.87 2.56 1.2 (VI 25 1 30.2 38.6 55.4 27.9 98.3 65.0 0.54 1�h _._-�.�._yx 13/16 142 1.95 1.22 4.08 2.56 1.2 40 X _ 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3 1 1 3/16 1.40 1.95 1.22 4.08 2.56 1.2 20 1 30.2 35.6 495 31.0 103.6 65.0 0.54 1 1 13/16 1.64 2.30 1.22 4.08 2.56 1.3 25 i 30.2 41.7 58.4 31.0 103.6 65.0 0.59 2 X 1/21 13/16 1.66 2.19 1.46 4.60 2.56 1.3 50 15 1 30.2 42.2 55.6 371 116.8 65.0 0.59 3/4 1 13/16 1.64 2.19 1.46 4.60 2.56 14 20 a 30.2 41.7 55.6 371 116.8 65.0 0.64 1 I 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 1 30.2 47.8 64.5 371 116.8 65.0 0.68 21/2 %x I 13/16 1.91 2.44 1.71 5.40 2.56 1.6 65 X 15 i 30.2 48.5 62.0 43.4 137.2 65.0 0.73 i 3k 1 13/16 1.89 2.44 1.71 5.40 2.56 1.6 20 1 30.2 48.0 62.0 43.4 137.2 65.0 0.73 ._._ 1 �� 13/16 2.13 2.79 1.71 5.40 2.56 1.6 25 j 30.2 54.1 70.9 43.4 137.2 65.0 0.73 1/2 1 1 3/16 1.91 2.44 1 71 5.50 2.56 1.6 761 mm X 15 i 30.2 48.5 62.0 43.4 139.7 65.0 0.73 34 j 13/16 1.89 2.44 1.71 5.50 2.56 1.6 20 1 30.2 48.0 62.0 434 139.7 65.0 0.73 1 1 13/16 2.13 2.79 1.71 5.50 2.56 1.7 25 1 30.2 54.1 70.9 434 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT(optional) male pipe threads only.Use of male threaded products with special features,such as probes,dry pen- dent sprinklers,etc.,should be verified as suitable for use with this Victaulic product.Failure to verify suitability in advance may result in assembly problems or leakage. *Center of run to engaged pipe end for NPT threads(dimensions are approximate). www.victaulic.com ir_tflg dire IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Eymvalent Length o1 1 inch Schedule do Steel Pipe Ipur UL Run Size e Jut e:Soe 213.Scclinn 16111 120)'.FT !niches/run Feet/meters 1/ X 1 8.5 32 25 2.6 1%x X 1 8.5 40 25 2.6 2 X 1 8.5 50 25 2.6 21/2 X 1 8.5 65 25 2.6 76.1 mm X 1 8.5 25 2.6 *Hazen-Williams coefficient of friction is 120 www.victaulic.com STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 \ /i 4 i dirt Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B3170NF) OTDLCQ • Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B317ONFF) cC) US Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) USTEG Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Ina Function: For fire sprinkler and other general piping purposes. Knurled ••••r swivel nut design permits hanger adjustment after installation. /" �! Features: • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe " types and protect CPVC plastic pipe from abrasion. Captured design , I keeps adjusting nut from separating with hanger. Hanger is easily a B f. installed around pipe. - For hanger with non captured nut order Fig. 200S. l'' • (21/2" (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in 1 i .. hanger before installation.Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" 115mml thru 8" (20omm1) Fig 200-1/2.200-3/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and ,! Fig.200-1 to 200-2 Fig.200-21/2 to 200-9 Factory Mutual Engineering Approved (FM) (3/4" (20mrn)thru 8" (2oomm)). Conforms to Federal Specifications VVW-H-171 E &A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 &SP-58, Type 10. Maximum Temperature: 650°F (343°C) iiii Finish: Pre-Galvanized. Stainless Steel d , . 1: materials will be supplied with (2) hex nuts 't in place of a knurl nut. Order By: Figure number and pipe size ` Designed to meet or exceed requirements of 1110 FM DS 2-0. ... 'a Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (15) 3/8"-16 31/a" (79.4) 25/8' 166.7) 11 (5.0) 200-3/4 3/4' (20) 3/8"-16 31/8' (79.4) 21/2' 163.5) 11 15.0) 200-1 1" (25) 3/a"-16 33/a" (85.7) 25/a' (66.71 12 (5.5) 200-11(4 11/4" (32) 3/8'-16 33/4" (94.0) 27/a' (73.0) 13 (5.9) 200-11/2 11/2° (40) 3/8"-16 37/e (96.4) 27/8" (73.01 14 16.4) 200-2 2" 150) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2' (65) 3/a"-16 55/a" (142.9) 41/a' 1104.7) 27 (12.3) 200-3 3" (75) 3/8"-16 57/a" 1149.1) 4" (101.6) 29 113.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8° (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (1001 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (1251 1/2%13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/a" (257.2) 63/4' (171.4) 73 (33.4) • 200-8 8" (200) 1/2'-13 131/8' (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 by E:1*N Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (rolco Fig. 103) B3205L - Threaded Rod (right& left hand threads) TL i' Specify Length Size Range: 3/8"-16 thru 3"-4 rod •L• -)j) Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL ,.11 Rod is threaded on both ends with right hand threads of the length shown.Also � � A available with left and right hand threads-specify Fig. B3205L when ordering. ��\ g p y Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/a"-16 21/2' 1 (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'1..' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) 93205-5/8X'L' 5/8"-11 21/2' (63.5) 2160 (9.61) 1692 (7.52) 93205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) 93205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) 93205-1 x'L' 1"-8 (101.6) 5900 (26.24) 4620 (20.55) 83205-11/4x'L' 11/8"-7 (114.3) 7450 (33.14) 5830 (25.93) 133205-11/4x'L' 11/4"-7 (127.0) 9500 (42.25) 7440 (33.09) 93205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.381 10807 (48.07) • 93205-13/4 x'1' 13/4"-5 7° (177.8) 18600 (82.73) 14566 (64.79) 83205-2 x'1' 2%41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 I (143.67) 25295 (112.51) B3205-21/2 x'12 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L' 21/a"-4 11" - (279.4) 49400 (219 73) 38687 i (172.08) 93205-3 x L 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length Material: Steel -" -. to) v Maximum Temperature: 750°F(399°C) - a o Finish: Plain. Contact B-Line for alternative finishes and materials. d d ..c V' Order By: Part number, rod diameter and finish 1.-Q Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"x length 20 240 (1.07) 12 (5.44) ATR 3/8"x 120 99-3/e"x length 16 730 (3.24) 29 (13.15) ATR 1/2"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 5/a"x 120 99-5t8"x length 11 2160 (9.60) 89 (40.37) ATR 3/4"x 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) • ATR 7/8"x 120 99-7/a"x length 9 4480 (19.93) 170 (77.11) AIR 1"x 120 99-1"x length 8 5900 (26.24) 225 (1o2A6) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B- Pipe Hangers&Supports 236 Revised 4/28/Z014 by E _T' e AlN VERTICAL MOUNT SAMMYS SAMMYS® for Steel insta Product Features �_ii1MIA_ n0 •Made with Tekse self-drilling fasteners- r pre"drI,'u required no pre-drilling required. req e •Install into steel range from 22 gauge-1/2°thicknesses. 41F " >" •Saves lime from traditional methods. +r1i 1 •Reduces installation cost- 'T K' •Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. 1 r g Approvals Rod Part Screw UPomate UL Test Load Min Max Box Case °' - *^ - ^* ;° fibs) Load fibs) Iba Thick Thick f J 1/4" 8024957 DSTR100- 1/4-20 x1"TEKS 3 1510 (20ga.) .036'-20ga 3116° ° 25 '12,5 1/4" 8025957 DST 100 1/4-14x 1"TEKS 3 446 (20 ga.) 036"-20 ga 3/16' 25 125 1/4" 8026957 DST 150 114-14 x 1-1/2"TEKS 3 970 (16 ga.) .036°-20 ga 3/16' 25 125 T; 114" 8027957 DST 200 11414 x 2"TEKS 3 446 (20 ga.) .036"-20 ga 3116" 25 125 1/4" 8030957 TEK 500 12-24 x 1-1/2"TEKS 5 3125(3/16") .187"-3/16° 1/2' 25 125 u '�" / L 2" 3/8" 8038957 DSTR 1' 11420 x 1''TEKS 3 1510 (20 ga.) 1500 1475 036"-20 ga 3116" 25 125 — 3/8° 8037957 DSTR 1-10* 12-24 x 1-1/2"TEKS 5 1510(3/16") 1500 1475 .060'-16 ga 1/2'. 25 125 tc2.,<> 3/8" 8039957 DSTR 516' 5/16-18 x 1-1/4"TEKS 3 2200 (20 ga.) 1500 1475 036"-20 ga 1/8" 25 125 446 (20 g a.) Black 3/8" 8040957 DST 10 1/4-14x 1"TEKS 3 .036"-20 ga 3/16" 25 125 970 (16ga) Nut Nut Driver uq- ga.) Part#8113910 3/8' 8077925 DST 10-SS 114-14 x 1"TEKS 3 970 (16 ga.) 036"-20 ga 3116" 25 125 //:7 446 (20 ga.) 3/8" 8041957 DST 15 1/4-14 x 1-1/2"TEKS 3 .036"-20ga 3/16" 25 125 970 (16ga.) k, 3/8' 8078925 DST 15-SS 11414 x I-112"TEKS 3 B70 (20 ga.) .036"-20 ga 3/16' 25 125 • T' . 318" 8042957 DST 20 11414 x 2 TEKS°3 970(446 �6 ga.) .036"-20 ga 3/16" 25 125 ''^ 446 (20 ga.) a 3l8" 8043957 DST 25 1/414 x 2-112"TEKS 3 970 (16 ga.) .036"-20 ga 3116' 25 125 3/8" 8044957 DST 30 1/4-14 x 3"TEKS 3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16ga.) Q.,Q 3/8" 8045957 DST 516 5/16.18x 1-1/4"TEKS 3 1500 (3/161 1500 1475 125"-1/8" 1/8" 25 125 v(„9 3/8" 8046957 TEK 50 12-24x1-1/2'TEKS 5 3125 (3/16") 1500 1475 .187°-3/16° 1/2" 25 125 112" 8031925 DST 2,0 11414 x 2"TEKS 3 446 (20 ga.) 188"-3/16" 1/4' 25 125 __. 970 (16 ga.) 1/2' 8033925 DSTR1.0" 1/4-20 x 1"TEKS 3 1510 (20 ga.) - .036"-20ga 3/16" 25 125 �""' 112" 8034925 DSTR 5.16* 5/16-18 x 1-114"TEKS 3 2220 (20 ga) 036"-20 ga 1/8" 25 125 '.1 1/2' 8035925 DST 5.16 5116-18x 1-1/4"TEKS 3 1500 (3/16") .125"-1/8" 1/8" 25 125 £ 1/2' 8036925 TEK 5.0 12-24 x 1-1/2"TEKS 5 3125 (3/16") 187"-3/16" 112" 25 125 #14 SW Red °: Nut Driver `Includes retaining nut Part#8114910 '''''' SAMMY Swivel Head for Steel 1'and swivels up to 1 in steel structure r Product Features illpP Eliminates distortion of threaded rod in •Installs into angled Z-Purlin;Allows sloped roof applications. threaded rod to hang plumb. •Accommodates 3-112 x 12 pitch. •Allows 17°deflection from vertical. r t` Rod Part Screw Ultimate ULTeat FM Test Min Max Box Case 4ii ° 318" 8132'957 SH-OS I61 1" '4 20 x 1 32201 3316") -500 1,175 035 3i16 25 125 'Includes retainingnut poesnof campy with ROHS requirements) #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.sammysuperscrew.com 6 0 111/- HS waewuarr `