Permit v CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT • COMMUNITY DEVELOPMENT Permit#: FPS2023-00089 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 8/15/2023 TIGARD Parcel: 1 S 127DD01200 Jurisdiction: Tigard Site address: 9875 SW CASCADE AVE Project: BMW of Tigard Subdivision: None Lot: None Project Description: Fire sprinkler:Add(925)sprinkler heads(wet and dry)for a 262,000 sq.ft.automotive dealership building. Contractor: HOWARD S WRIGHT Owner: HOLMAN TIGARD REAL ESTATE LLC 1455 NW IRVING STREET#400 17800 SE MILL PLAIN BLVD#190 PORLAND,OR 97209 VANCOUVER,WA 98683 PHONE: 503-601-9939 PHONE: FAX: FEES Description Date Amount Specifics: Permit Fee-COM 08/14/2023 $3,970.38 12%State Surcharge-Building 08/14/2023 $476.45 Type of Use: COM Plan Review-Fire Life Safety-COM 08/14/2023 $1,588.15 Class of Work: NEW Type of Const: IA Info Process/Archiving-Lg$2.00(over 08/14/2023 $30.00 Occupancy Grp: B Height: 50 ft 11x17) Stories: 4 Info Process/Archiving-Sm$0.50(up to 08/14/2023 $127.00 11x17) Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Wet Standpipe Required: Yes Hazard: ORD1 Density: 0.1 Design Area: 1500 K Factor: 5.6 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $6,191.98 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $804,000.00 1 Special Inspection(see plans) Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules Issued Ey: Permittee Signature: Call 503.639.4175 b :00 a.m.for the next available inspection date. This permit card shall be kept i conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. RECEIVED JUL 1 0 2023 Walter L. Cook PE / PRpCITY OF TIGARD Fire Protection Engineering Since 1991;TV — ossBUILDING DIVISION �cGINe- ogliooy signed q'Wan cook Jul 6 2023 �� 10001 � < o°_°s. y / / E• Meling'.dJoA�+k.u6, —Walt Cook PE awe`R.l,e.,cn.wmcooe Mr. Patrick Nelligan, ET °� °"°'°° �s es:�am'go McKinstry OREGON 16790 NE Mason St S200 O �� Portland, OR 97230 , 15,19, OJ RE: Engineering Review Approval—automatic sprinkler system` �TFR L GO BMW Dealership,Tigard OR Dear Patrick, EXPIRES: 12/31 / 2023 Enclosed under cover of this letter are the following document sets; • 15 Shop Drawings, • Hydraulic Calculations, • Seismic Calculations • Material Data Submittals I find that this design package, prepared by McKinstry, is in general conformance with the intended project design. The submittal has been reviewed only for the limited purpose of checking for general conformance with the design concept as expressed in the Contract Documents, subject to the requirements of the Contract Documents. For the above referenced document sets I have reviewed the drawings, hydraulic and seismic calculations referenced above. I find that the documents appear to be compliant with codes including in part 2016 NFPA 13,ASCE 07, 2019 OSSC,2019 OFC as well as specific requirements of the City of Tigard; including the following notations. • The applicable codes are based on the date of the initial building permit application, • Seismic brace calculations were prepared using TOLCO Calculator, spectral acceleration for actual building location and highest floor were evaluated. The pre- cast building structural system was not evaluated for attachment and bracing of sprinkler piping, • The scope the PE Seal on this letter is limited to the documents and calculations referenced above. The drawings and calculations were prepared under my supervision and control in accordance with OSBEEL standards. The Oregon PE seal on this letter encompasses the drawings and calculations referenced above, subject to the conditions stated herein and approval from McKinstry and city of Tigard. Please contact me at your convenience if you need any further assistance during the approval and permit process. Sincerely Walter L.Cook PE Cc Ken Thackery PHONE (503)333-3470 13467 SW Summerwood Dr WER-I E-MAIL ENGINEERING@WALTCOOK.US Tigard,OR 97223