Loading...
HomeMy WebLinkAboutReport (2) FP52422.- Oo(35- 7255 SW DRICTMOU7 S r Honeywell Addressable Fire Alarm Control Panels SILENT` ICNICHT 6808 RECEIVE .. OCT 26 2022 Addressable Fire Alarm Control Panel CITY OFTIGARD BUILDING DIVISION The 6808 is an addressable fire alarm control panel(FACP)that is a direct replacement for the 5808 FACP.The 6808 can be configured to achieve a point capacity of 198 points.It has one built-in signaling line circuit(SLC),which can support 99 System Sensor'(SK)sensors and 99 SK modules or 127 Hochiki'5(SD)devices per loop. A common communications and annunciation link allows up to 17 panels to he connected via copper or fiber optic cable.A designated panel is configured as the communicator for all panels in the link for convenient single-point communications.It also has a built-in,dual- line POTS and IP communicator with additional cellular options available. 6808 The 6808 system can be enhanced by adding modules such as the The supports a variety of devices,including the 6860 remote annunciator which also has four programmable function 6860,5860,and 6855 remote annunciators,5824 buttons to help automate tasks and reduce time spent at the panel. serial parallel printer interface module(for printing system reports),the 5496 NAC expander,5895XL SWIFT'wireless compatibility provides options for wireless detection power module,and SK or SD devices. through a Class A mesh network.It is ideal for hard-to-wire locations, buildings where new wiring is not allowed,or to provide an easy install fire system for new construction projects.SWIFT devices can be combined with other hard-wired 6808 compatible devices. The 6808 also has a form-C trouble relay,two programmable form-C relays,along with powerful features such as drift compensation,pre- trouble maintenance alert,a built-in sensor test to comply with NFPA 72 calibration testing requirements,and calibration trouble alert. H . A ( lR > & 47EN - i- l S • Capable of providing • Convenient • 6860 annunciator with • Programmable date • 125 software zones up to 198 points to field-upgradeable a 4 x 40 large display setting for automatic and 125 output satisfy smaller firmware . Four user- and convenient groups for ftexible installation needs , guilt-in dual path programmable buttons Daylight Saving Time design options • Connect up to 17 POTS and IP minimize tirne spent changes panels on one site with communications with executing complex or • JumpStart' auto convenient single- optional cellular routine tasks programming reduces point access using the models available for , guilt-in USB interface installation time SIC-MC Network reliable backup for convenient and Interface Card. reporting Connected panels can quick programming have mixed compatible FACP models OFFICE COP\ SIGNAL LINE CIRCUIT(SLC) PROGRAMMING ORDERING INFORMATION The 6808 SLC loop supports multiple The 6808 system offers several options 6808:Addressable Fire Alarm device types,maintenance alerts,and a to simplify and speed-up programming. Control Panel.(Red cabinet). built-in sensor test to comptywith NFPA JumpStart'auto programming 72 calibration testing requirements. minimizes programming required to start COMPATIBLE ANNUNCIATORS a new system.The built-in keypad,or the 6860:4x40 LCD remote fire INDICATOR LIGHTS 6860,5860 or 6855 remote annunciator(4 tines and up to • General Alarm(Red):Flashes if in annunciators give you on-site access to 160 characters)per system;four alarm:solid when alarm is silenced current system programming. programmable buttons • Supervisory(Yellow):Flashes if a Programming can also be accomplished 5860:4x20 LCD remote fire supervisory condition exists;solid using the Windowsro-based Honeywell annunciator.5860 is gray;5860R is red when supervisory is silenced Fire Software Suite(HESS)program. 6855:4x20 LCD remote fire • System Troubles(Yellow):Flashes annunciator SOFTWARE TOOLS if a trouble condition exists; 5865-3 or 5865-4:LED annunciators SKST:Silent Knight Selection Tool solid when trouble is silenced can display up to 30 LEDs(15 red and provides the installer or design architect 15 yellow).The 5865-4 has key switches • System Silenced(Yellow): with a Windows'software system for silence and reset,and a system On when an alarm,trouble or configuration tool to create a detailed Bill trouble LED. supervisory condition has been of Material MOM)and battery silenced but notyet cleared 5880: LED/10 module has 40 calculations. programmable LED outputs and eight • System Power(Green):Flashes HFSS:Honeywell Fire Software Suite supervised dry contact inputs which are for AC failure;solid when provides communication and panel useful for custom applications.You can power systems are normal programming,detector status,event use up to eight 5880 modules on one history and additional data.Requires a controlpanel for maximum flexibility. INTERFACE PC running Microsoft''Windows'. Its compact size allows mounting inside The 6808 built-in 4 x 20 annunciator with 80 character LCD display ADDITIONAL INFORMATION the annunciator,or in an accessory and large easy--to-use tactile Twisted-unshielded pair cabinet. touchpad can be used for system wire is recommended. 6808 COMPATIBLE DEVICES AND operation, programming and The 6808 also has 13 preset notification ACCESSORIES maintenance.It has five LEDs for cadence patterns See the data sheets listed below for a alarm,supervisory,system trouble, complete listing of the SK,SD or SWIFT (including ANSI 3.41). devices. system silenced and system power. 53623:SK Devices Data Sheet AGENCY LISTINGS AND APPROVALS 5367.4:SD Devices Data Sheet System operations include silencing NPFA 13,NFPA 15,NFPA 16,NFPA 70, 350614,350616&350618:SWIFT alarms and troubles.resetting alarms NFPA 72:Central station;remote wireless devices and the display of alarm troubles and Signaling:Local Protective Signaling For a complete and current listing of memory.The system's non-volatile Systems;Auxiliary Protected Premises compatible devices and accessories,visit event historybuffer stores 1,000 www.silentknight.com. Unit;Water Deluge releasing service. Important:You cannot mix SK and SD events for viewing from the built- Suitable for automatic.manual, devices in the same fire alarm system. in or remote annunciator.System waterflow,sprinkler supervisory(DACT operations can be initiated with a non-coded)signaling services mechanical firefighter's key or a • UL Listed:52766 valid 4-to 7-digit operator's code. • CSFM:7165-0559:0502 • FDNY:COA#6246 • FM approved Page 2 of 4—351608:B 9/26/2018 ' SK COMPATIBLE ADDRESSABLE B200S-LF(-IV,-WH):Low-Frequency WSK-WGI:Wireless Gateway DEVICES intelligent sounder base WSK-PHOTO:Wireless Photoelectric smoke SK-ACCLIMATE:Multi criteria B200S-LF:Low-frequency intelligent detector photoelectric smoke detector with thermal sounder base WSK-PHOTO-T:Wireless Multi-criteria 135°F fixed temperature 8224RB(-IV,-WH):Relay base photoelectric smoke detector with thermal SK-BEAM:Reflected beam smoke detector 8224RB: Relay base detection(135°F fixed temperature)and withouttestfeature 622461(-IV,WH):Isolator base B510W4°base SK BEAM T:Reflected beam smoke B224BI: Isolator base WSK-HEAT:Wireless Heat,(135°F fixed detector with test feature temperature)and 8510W 4"base SK-CONTROL:Supervised control module SD COMPATIBLE ADDRESSABLE WSK-HEAT-ROR:Wireless heat,ROR SK-CONTROL-6:Six circuit supervised DEVICES (135°F fixed temperature)and 8510W 4" control module SD505-6AB:Addressable 6"base base SK-DUCT:Photoelectric duct smoke SD505-61B:Addressable 6°short circuit WSK-MONITOR:Wireless monitor module detector with extended air speed range isolator base WSK-RELAY:Wireless relay module SK-FIRE-CO:Four criteria fire and carbon SD505-6RB:Addressable 6"relay base W-USB:SWIFT Toots USB transceiver used monoxide detector SD505-6SB:Addressable 6"sounder base for communication with SWIFT devices SK-HEAT:Fixed thermal detector(135'F) SD500-AIM:Addressable input module SK-HEAT-W:Fixed thermal detector (switch input) SBUS ACCESSORIES (135°F),white SD500-ANM:Addressable notification 5496:A 6 amp notification power expander SK-HEAT-ROR:Fixed rate of rise detector module with four power-limited notification (135°F) SD500-ARM: Addressable relay module appliance circuit outputs. SK-HEAT-ROR-W:Fixed rate of rise SD505-DTS-K: Remote test switch and 5883:Relay Interface.Provides 10 Form C detector(135°F),white LED indicator for the SD505-DUCTR relays. SK-HEAT-HT:Fixed high temperature SD505 DUCT:Addressable Duct Smoke 5824:Serial/Parallel Printer Interface thermal detector(190°F) Detector. Module for printer connection. SK-HEAT-HT-W:Fixed high temperature "` SD505 DUCTR:Addressable Duct 5895XL:Power Supply with six Flexput thermal detector(190°F),white Detector housing with relay base. circuits,and two Form C relays.Max.16 per SK-ISO:Fault isolator module system. SK-MINIMON:Mini monitor module SD505 HEAT:Absolute temperature heat 5815RMK:Remote mountingkit. detector.Trip point range from SK-MONITOR:Monitor module 135°F-150°F(0°C-37°C). Dimensions:10 3/8"W x 10-3/16"H x 3''D SK-MONITOR-2:Dual input monitor SD500-LIM:Addressable Line isolator COMMUNICATION OPTIONS module module SK-MON-10:10 input monitor module SD500-MIM:Addressable Mini input CELL-CAB-SK:Cellular communicator, * SK-PHOTO:Photoelectric smoke detector monitor module(switch input) metal enclosure with lock/key SK-PHOTO-W:Photoelectric smoke SD505-PHOTO:Photoelectric smoke CELL MOD:Cellular communicator,plastic detector,white detector enclosure* SK-PHOTO-T:Photoelectric smoke detector SD500-PS/-PSDA:Addressable Single or Sole path,powered by panel. with thermal(135°F fixed temperature) dual action pull station IPGSM-4G:Dual path fire alarm SK-PHOTO-T-W:Photoelectric smoke SD500-SDM:Addressable smoke detector communicator,cellular and/or IP(primary or detector with thermal(135°F fixed module backup,selectable) temperature),white SK-IP-2:Remote reporting via the Internet. SK-PHOTOR:Photoelectric detector with AUDIBLE/VISIBLE DEVICES Requires a VisorAlarmv receiver at the central remote test capability These AV devices are all 2-wire.Color:"R" station SK-PHOTO-R-W:Photoelectric detector indicates red;"W"denotes white.For a MISC.ACCESSORIES with remote test capability,white complete listing of Silent Knight AV devices SK-NIC:Network Interface Card.Provides a SK-PULL-SA:Addressable single action go to www.silentknight.com, common communications link for the 6808. pull station CHSRL/CHSWL:Wall chime/strobe SK NIC KIT:Installation Accessory Kit SK-PULL-DA:Addressable dual action pull CHSCRL/CHSCWL:Ceiling chime/strobe station CHRL/CHWL:Wall chime SK-FML:Fiber-Optic Multi Mode, transmitter and receiver SK-RELAY:Addressable relay module H RL/HWL:Walt horn SK-FSL:Fiber-Optic Single Mode SK-RELAY-6:Addressable Six relay control P2RL/P2WL:Wall horn/strobe module RBB:Remote battery box accessory cabinet SK RELAYMON 2:Addressable Dual PC2RL/PC2WL:Ceiling horn/strobe for batteries that are too large to fit in the elay/monitor module SRL/SWL:Wall strobe FACP cabinet.Dimensions:16"W x 10"H x rSK-ZONE:Addressable zone interface SCRL/SCWL:Ceiling strobe 6"D(406mm W x 254mm H x 152mm D). module SPSCRL/SPSCWL:Ceiling speaker/strobe SK-SCK:Seismic Compliance Kit used to SK-ZONE-6:Six zone interface module SPSRL/SPSWL:Wall speaker/strobe securely fasten batteries to the fire panel. B300-6(-IV):6"base for SK-W Series SPRL/SPWL:Wall speaker B210LP:6"mounting base SPCRL/SPCWL:Ceiling speaker B501(-BL,-IV,-WHITE):4"flangeless base B501:4'Flangeless mounting base SWIFT WIRELESS DEVICES B200S(-IV,-WH):Intelligent sounder base SWIFT is only compatible with System B200S:Intelligent sounder base Sensor(SK)devices.It is not compatible with Hochiki(SD)devices. Page 3 of 4— 351608:B 9/26/2018 • • 6808 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS(NACs) Ftexpute,Honeywell", Overall Dimensions:.16.36"W x 26.37"H x 3.91"D Four programmable circuits which can be JumpStarte,Silent Knight". programmed individually as: SWIFT"",and System Shipping Weight:32 lbs. Sensor'=are registered Color:Red NACs:3A @ 27.4VDC per circuit,power-limited trademarks of Honeywell (with a maximum current of 6A) International Inc. ENVIRONMENTAL Auxiliary Power Circuits:3A(a 27.4VDC per circuit, Hochiki'is a registered Operating Temperature:32°F to 120°F (0°C to power-limited trademark of Hochiki 49°C) Corporation.Microsoft`' Humidity:0 to 930/0 relative humidity(non- Supports Class B(Style 4)and Class A(Style 6 or 7) and Windows"are condensing) configuration for the SLC registered trademarks of Microsoft Corporation. ELECTRICAL WIRING:See the product manual for wiring details This document is not 6808 Primary AC:120 VAC-.5,760Hz,3.3A Total intended to be used for Accessory Load:6A @ 27.4VDC power-limited installation purposes.We Standby Current:190m4 try to keep ourproduct information up-to Alarm Current:250mA date and accurate.We Battery Charging Capacity:7 to 35AH cannot cover all specific Battery Size:7AH to 18AH max.allowed in control applications or anticipate all.requirements.All panel cabinet.Larger capacity batteries can be specifications are subject housed in RBB accessory cabinet. to change without notice. Far-Technical Support,call 800-446-6444. Honeywell Silent Knight 12 Clintonville Road HOne3'well Northford,CT 06472 35.1608 I 8 I 09/18 raSILENT 800-328-0103 C U 2018 Honeywell Inte.nationanc. KNIGHT te - x Honeywell .. lr ®SILENT" 1" v.£ . „ ": :.; 1 £' q,y 1 5 LL " r6 KNIGHT 111111 = ..... x .. J k o ltla,,- 't, .q 55 SK-RELAY Intelligent Relay Modulerv, „�;, �'r w tl , tom ;. . .a - e �' : The SK-RELAY is an addressable relay module for use with Honeywell Silent Knight Series fire alarm control panels(FAC:Ps).The SK-PEI_AY allows a Apl t Silent Knight FACPto switch discrete contacts by code command,The i relay contains two isolated sets of Form C contacts,which operate as a + DPDT switch.No supervision is provided for the notification appliance circuit. .i:. Honeywell SilltiE' The SK-RELAY contacts can be used for virtually any normally open or � �r„;� .alp a normally closed application.Each SK-REL AY is programmed wiii.h a unique signaling line circuit(SLC)loop address.When an event occurs that controls the SK-RELAY,the relay is triggered by the EAU. ry i INSTALLATION i The SK-RELAY mounts directly into a 4`scivare electrical box.The box must SK-RELAY have a minimum depth of 2-1/8".A surface mount electrical box(System Sensor'PN SMB500)is available from Sd:ent Knight. rEAT3U R ES & FENCE TS • Two sets of Form C • Panel controlled • Polling LED visible contacts status LED that through the cover • Rotary address flashes green in plate switches for fast normalstate and is • SEMS screws for easy installation solid red in alarm wiring • Contacts are rated for ' Relay programming is • UL Listed a variety of amps(see completely flexible- Specifications) can be mapped to zone conditions • SK-PELAY Technical Specifications For a complete listing of all. compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION wwwsitentknight.coght.cam. 4.675"H x 4.275'W x 1.4"U 5K-RELAY:Relay Module Shipping Weight:6.3 oz(196 g) Microsoft,Windows,and ACCESSORIES. the Windows Logo are registered trademarks ELECTRICAL SMB500:4"Square Surface Mount Electrical Box or trademarks of Operating Voltage:15-32 VDC CB500:Module Barrier Microsoft Corporation. End-of-Line Resistance:Not used SLC Standby&Alarm Current:.255mA max® COMPATIBILITY Silent p'K and H System 5ensci"and HoneywelC" 24VDC(one communication every 5 sec with LED The SK-RELAY is compatible with the following are registered enabled) Honeywell Silent Knight fire alarm control panels: trademarks of Honeywell 6820:Addressable fire alarm control panel International,Inc. ENVIRONMENTAL 6820EVS:Addressable fire alarm control panel This document is not Operating Temperature:32Eff-120 W(0( - with an emergency mass notification system. intended to he used for 49 Er) 6808:Addressable fire alarm control panel installation purposes.We Humidity:10%-93°/o non-condensing try to keep our product 6700:Addressable fire alarm control panel information up-to RELAY CONTACT RATINGS 5700:Addressable fire alarm control panel date and accurate,We 5808:Addressable fire alarm control panel cannot cover all specific 3.0A,®30VDC resistive applications or anticipate 0,9A @ 110VDC resistive 5820XL:Addressable fire alarm control panel all requirements.All 0.9A a.125VAC resistive 5820XL-EVS:Addressable fire alarm control panel specifications are subject with an emergency mass notification system. to change without notice. 0,5A 125VAC inductive(PF=.35) 0,7A p. 75VAC inductive(PF=.35) For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com H2 Clintonville Silentdight• Honeywell 12 Gntonvilie Road NOrthfOrd,CT 06472 Doc 3501271 Rev GI 11/17 � SILENT 800-328-0103 ©2017 Honeywell International Inc. KNIGHT Honeywell � h d Sol KNIGHT SK-MONITOR Intelligent Monitor Modules The SK-MONITOR is an addressable monitor module for use with Honeywell Silent Knight Series fire alarm control panels(FACks) The SK-MONITOR is intended for use in intelligent two-row e systems,where individual address of each module is selected using the built it rotary ors- switches. "• The SK-MONITOR supports Class A supervised or Class B supervised wiring to the load device.Conventional Li wire smoke detectors can be * monitored for alarm and trouble conditions.. - N INSTALLATION The SK-MONITOR mounts directly into a 4"square electrical box.The box must have a minimum depth of 2-1/8".A surface mount electrical box SK-MONITOR (System Sensor'PN SMB500)is available from Silent Knight. iy,a Y ATaPiE. `-; B . fN TITS • Single contact monitor • Panel controlled • UL Listed • Support for Class A status LED that • Rotary address and Class B wiring flashes green in switches for fast normal state and is installation • Fully supervised solid red in alarm • SEMS screws for easy wiring SK-MONITOR Technical Specifications For a complete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.sitentknight.com. Height:4.5"H x 4"W x 1.25°D(11.4 X 10,2 X 3cm) SK-MONITOR:Monitor Module Microsoft,Windows,and Shipping Weight:6.3 oz(196 g) the Windows Logo are ACCESSORIES. registered trademarks ELECTRICAL SM8500:4"Square surface mount electrical box or ti ademarks of Operating Voltage:15-32VDC Microsoft Corporation. COMPATIBILITY Current Draw(LED on):S.OrnA max Silent Knight,System The SK-MONITOR is compatible with the Sensor'and Honeywell' Operating Current(LED flashing):375µAy Standby Current:400 µA max;a 24 VDC(one following Honeywell Silent Knight fire alarm are registered communication every5 sec with 47K EOL);550 A control panels: trademarks of Honeywell µ 6820:Addressable fire alarm control panel International,Inc. max tl 24 VDC(one communication every 5 sec with E01..<1K) 6820EVS:Addressable fire alarm control panel This document is not 5.5 mA(with LED latched on) with an emergency mass notification system. intended to be used for LED Current:5.5 mA(with LED latched on) 6808:Addressable fire alarm control panel installation purposes.We End-of-Line Resistance:47KS2 6700:Addressable fire alarm control panel try to keep our product information up-to Initiating Device Circuit Wiring Resistance:1,500 5700:Addressable fire alarm control panel date and accurate.We S2 max 5808:Addressable fire alarm control panel cannot cover all specific SLC Loop Resistance:40 C2 max. 5820XL:Addressable fire alarm control panel applications or anticipate all requirements.All 5820XL-EVS:Addressable fire alarm control panel specifications are subject ENVIRONMENTAL with an emergency mass notification system g y y to change without notice. Operating Temperature:32e, -120EfF(0W- 49M) For Technical Support, Humidity:10°/a-93%non-condensing call800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell N orthford,CT 06472 Doc 3501311 aev G 1 11/17 ®SILENT" 800-328-0103 @2017Honeywell International Inc. KNIGHT • SYSTEM `.$ SENSOR Indoor Selectable- 0- Output Strobes and Horn Strobes for --- Ceiling Applic ations 1a OuyuGmM f d} � • System Sensor L-Series audible visible notification41, products are rich with features guaranteed to cutf rr installation times and maximize profits with lower w It current draw and modern aesthetics. Features The System Sensor 4Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela The entire L-Series product line of ceiling-mount strobes and horn • Field-selectable candela settings on ceiling units: 15,30, 75,95, 115, 150, and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring, installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. • Agency Listings SIGNAUNG LISTED Amp `_ I $5512 FM approved except 7125-16530504 $4011 for ALER1 models 7135-10.5311503 300/333 AVD6868.02.12/01/2017•Pago 3 L-Series Specifications ArchitecVEngineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11 -inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17B-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit`°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115, 150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also.while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mrn diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. Avos868-o2.12.1 V217•?ape 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 _ 95 N/A 134 164 Non-Temporal Low 29 32 54 .115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Terporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS860.02.12/01/201 7•Page 3 L-Series Dimensions 2.47*(62.7 mm) ---- - -n 1.3T(34.8 mm) - - ----°- 6.92'diam. , 6.83°diam.—. 1 (175.77 mm) (64 mm) (173 mm) ; ',. 1 y ••tin`_— , .—, I I I 4R- o O c - ' ir I 1 1 IC 0 i , o_/4.-;'__ // A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box 0 g o 1 ���� c=, / / /� s a'tr K 0YA S\ 1 ® I'— �a'b'�' r i g' \ N Y,%'4,ros ;+�,0%;,°tt VaI /�,p� yryzyxi 2s\/\1 ,.Z--.-:.-,-'--'i.-.'----7--,.-.' ',.,----'-,, \ \\ `® �\i // / , 1pwYY trail 1 Y II • /1Y 0, \ / • �' it '•i Otti I Mrrtitil 7tll, ' l ��J'ti' o9r \--_._ —% Aoasa.ol - A0531 of 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". Wo, SYSTEM ®2017 System Sensor SENSOR" 3825 Ohio Avenue•St. Charles, IL 60174 Product specifications subject to change without notice.visit systemsens;r.cam Phone:800-SENSOR2•Fax:630-377-6495 far cmront product inhumation,including the latest version of this&Ca sheet AVnS886-02•12/01)2017 SYSTE S #I. ,1 Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications ;1t . System Sensor L-Series audible visible notification products are rich with features guaranteed to cutj installation times and maximize profits with lower current draw and modern aesthetics. Features ` .fr.. • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings, standard and compact devices,and plain,FIRE, and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30, 75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+d8A at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNAUNG LISTED APPROVED S5512 FM approved except 1123-1613'1a0A S4011 for ALERT models 7135-1633WIT 3057383,3057072 AVDS865-05•2/2212018•Page 1 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1'1/R-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit`"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts,When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4t1/18 x 411/18 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to I20°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6""L x 4.7""W x 1.91"D(143 mm L x 119 rnrn W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 rnm D) Horn Dimensions 5.6"L x 4.7"'W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1, Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVD5885 05•2.'22,2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern _ dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3 1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1 K Temporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9' Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 'Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865.05•2/22/2018•Page 3 L-Series Dimensions 4A5 mm Nmm " ',—! --_.1.25' 3.57•-- N mm 1.25' 89 mm — f 32 mm (A7 and \\ (3.9 cm) eigm I 1 4IL i° ° ' ; C S.Y7^ maw, °o °n°°°u a � 5'39' 133.9 mm NII A77• °° °°OO°I tlA7 an) MOO 1°s44.14t ] 1•0001s0 Al V A0548-04 A0547-00 A0557-40 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL (11.84 cm) 1.91' (4.85 cm) 9.T .. 1.25' ///�'`118 mm i 31 mm (1224 cm) 0.N°m cl! _ , (3.18 mm) ( I slit SST' •++++•• 5.97" x i ;1e e9 an) "AM 0 VI a1V 111° Mtt°1 ' i°iititi°i ! 00550 00 A0555-00 A0554 DI Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRL/SBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes Horns* P2RL 2-Wire,Horn Strobe,Red HRL* Horn,Red P2WL 2-Wire,Horn Strobe,White HWL* Horn,White P2GRL 2-Wire,Compact Horn Strobe.Red HGRL* Compact Horn, Red P2GWL 2-Wire,Comp 2 fils act Horn Strobe,White HGWL° Compact Horn,White P2RL-P 2-Wire.Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White SBBGRL Compact Wall Surface Mount Back Box, Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red, FUEGO SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover), All-SP models have"FUEGO'marking on cover. All-ALERT models have"ALERT"marking on cover. 'Horn-only models are listed for wall or ceiling use. *� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ®218 System Sensor. I l Phone: 800-SENSOR2•Fax:630-377-6495 Product° 6cationssueiee'tochangswnn�notice_v's'tsystemsenso,emn SENSOR' E .SOR 1n canon product infvmation,in'A,d'mg the latest Vrersien of this data sheet. /�( www.systemsensor.corn AVtS865-05.2/02;2016 5K- PH SERIES Addressable Photoelectric Smoke Detectors The Silent Knight'' SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and (r maintenance efficiency. � rzP The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both , ll performance and aesthetics,and are direct replacements for the SK-PHOTO Series detectors.A new modern,sleek,contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel.Point ID capability allows each detector's address to be set with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level.Dual electronic thermistors add 135°F(57°C)fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector housings. FEATURES AND BENEATS • Designed to meet UL 1268 7th Edition steady red in Alarm • Sealed against back pressure • Sleek and stylish contemporary design • Integral communications and built-in • Plugs into separate base for ease of • Stable communication technique with device-type identification installation and maintenance noise immunity • Remote test feature from the panel • Expanded color options • Addressable by device • Built-in functional test switch activated by • SEMS screws for wiring of the separate base • Rotary,decimal addressing(Refer to the external magnet • Optional remote,single-gang LED Silent Knight panel manuals for device • Walk test with address display(an address accessory capacity) of 121 will blink the detector LED 12- • Optional sounder,relay,and isolator bases • Two-wire SLC connection (pause)-1) • LEDs blink every time the unit is polled • Low standby current • 360°-field viewing angle of the visual alarm • Built-in tamper-resistant feature indicators(two bi-color LEDs);LEDs blink • Designed for direct-surface or electrical- HoneyWGll green in Normal condition and turn on box mounting ®SILENT' KNIGHT • INSTALLATION B200SR-LF-WH:White,Low Frequency Intelligent sounder base The SK-PHOTO-W Series plug-in intelligentthermaldetectors use a for retrofit applications separate base to simplify installation,service,and maintenance. B200SR-LF-IV:Ivory,Low Frequency Intelligent sounder base for Installation instructions are shipped with each detector. retrofit applications Mount base(all base types)on an electrical backbox which is at B224RB-WH:White,plug-in System Sensor®relay base least 1.5"(3.81 cm)deep.For a chart of compatible junction boxes, B224RB-IV: Ivory,plug-in System Sensor relay base see SK-61045. B22481-WH:White,plug-in System Sensor isolator detector base Note:Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required.Wiring"T-taps"or branches B224B1-IV:Ivory,plug-in System Sensor isolator detector base are permitted for Style 4(Class"B")wiring. ACCESSORIES Note:When using relay or sounder bases,consult the SK-ISO TR300:White,replacement flange for B210LP or B300-6 bases installation sheet 156-3627 for device limitations between isolator TR300-IV:Ivory,replacement flange for B210LP or B300-6 bases modules and isolator bases. RA100Z(A):Remote 3-32 VDC LED annunciator,mounts to a U.S. OPERATION single-gang electrical box,for use with B501 and B300-6 bases Each SK-PHOTO-W Series detector uses one of the panel's addresses only (total limit is panel dependent)on the Signaling Line Circuit(SLC).It M02-04-00:Test magnet responds to regular polls from the control panel and reports its type and the status.If it receives a test command from the panel(or a local M02-09-00:Test magnet with telescoping handle magnet test),it stimulates its electronics and reports an alarm.It blinks CK300:White,detector color kit,pack of 10 its LEDs when polled and turns the LEDs on when commanded by the CK300-I11:Ivory,detector color kit,pack of 10 panel.The SK-PHOTO-W Series offers features and performance that CK300-BL:Black,detector color kit,pack of 10 represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note:"-IV"suffix indicates ivory color. SK-PHOTO-W:White,low-profile photoelectric sensor SK-PHOTO-T-W:White,same as SK-PHOTO-W but includes a built-in 135°F(57°C)fixed-temperature thermal device SK-PHOTO-R-W:White,low-profile intelligent photoelectric sensor, remote test capable,for use with DNR/DNRW B300-6:White,standard flanged low-profile mounting base B300-6-13P:Bulk pack of B300-6,package contains 10 B300-6-IV:Ivory,standard flanged low-profile mounting base B501-WHITE:White,standard European flangeless mounting base B501-BL:Black,standard European flangeless mounting base B501-IV:Ivory,standard European flangeless mounting base 6501-WHITE-BP:Bulk pack of B501-WHITE,contains 10 B200S-WH:White,Intelligent,programmable sounder base B200S-IV:Ivory,Intelligent,programmable sounder base B200SR-WH:White,Intelligent sounder base for retrofit applications B200SR-IV:Ivory,Intelligent sounder base for retrofit applications B200S-LF-WH:White,Low Frequency Intelligent,programmable sounder base B200S-LF-IV:Ivory,Low Frequency Intelligent,programmable sounder base Page 2 of 3—351634:B•7/1/2019 SK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL DETECTOR SPACING AND Sensitivity: APPLICATIONS Silent Knight'and System Sensor' are registered trademarks of - UL Applications:0.5%to4.0%per foot Silent Knight recommends spacing Honeywell International,Inc. obscuration. detectors in compliance with NFPA 72.In - ULCApplications:0.5%to3.5%perfoot lowairflowapplicationswithsmoothceiling, This document is not intended to be =p obscuration space detectors 30 feet(9.1m).For specific used for installation purposes.We Size:2.0"(5.3 cm)high;base determines information regarding detector spacing, try to keep our product information placement,and special applications refer to up-to-date and accurate.We cannot `. diameter p NFPA 72.A System Smoke Detector cover all specific applications or - B300-6:6.1"(15.6 cm)diameter Application Guide,document A05-1003,is anticipate all requirements.All - B501:4"(10.2 cm)diameter available at www.systemsensor.com. specifications are subject to change For a complete list of detector bases,see without notice. AGENCY LISTINGS AND SK-61045. Shipping weight 3.4 oz.(95 g) APPROVALS Country of origin;Mexico These listings and approvals apply to the Operating temperature range: modules specified in this document.ln some • SK-PHOTO-W:32°Fto 122°F(0°C to 50°C) cases,certain modules or applications may ° gam-= " • SK-PHOTO-T-W:32°Fto100°F(0°Cto not be listed bycertain approval agencies,or 38°C) listing may be in process.Consult factory for • SK-PHOTO-R-W installed in a DNR/DNRW: latest listing status. -4°F to 158°F(-20°C to 70°C) • UL Listed:S6173 UL/ULC Listed Velocity Range:0-4000 ft/ • FM Approved min.(1219.2 m/min.),suitable for • CSFM:7272-0559:0512 installation in ducts Relative humidity:10%-93%non- condensing Thermal ratings:fixed-temperature set point 135°F(57°C),rate-of-rise detection 15°F(8.3°C)per minute,high temperature heat 190°F(88°C) ELECTRICAL SPECIFICATIONS Voltage range:15-32 volts DC peak Standby current(max.avg.):200pA®24 VDC(one communication every 5 seconds with LED enabled) Max current:4.5 mA i 24 VDC("ON") Honeywell Silent Knight 12 Clintonville Road Honeywell Northf°rd,CT 06472-1610 203.484.7161 351634 I a 107/19 ®SILENT www.silentknight.com ©2019 Honeyveuinternauonaun°. KNIGHT -.141111 ' Honeywell DSILENrf KNIGHT SK-PULL-SA / SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull stat on rego:rring Unty one motion Lo ,-ri,PfteirlINV. activate the station.1 he SK-PULL-DA is a dual adion putt I. Lon roqu;ring two motions to active the station.The SK- .'iiLL SA and SK-PULL-DA are for use with with Honeywell Silent Knight Series fire control panel -AC PULL PULL DOWN 4, :,!!:i;VAilpipillt Extremely easy to operate,the SK-PULL-DA and SK-PULL-SA provide a fast r-Art.4344',1051 and practical means of manually initiating a fire alar ril signal, The FACP r recognizes each manual pull station by its t,peufic agriress saving preg,ous 1 'f/...:,7 rtittrO.VyiL seconds in determining the location of,.. r-1 g'.arrn. Honeywell - •1. -21,--_i,r.,,',,..' r':',.,i11 C.1;:!:1,),, . a INSTALLATION The SK-PULL-SA and SK-PULL-DA can bo sur`acc mo to unted an SB I/O SK-PULL-SA surface back box or semi-flush mounted nn a star dard s Ingle gang with minimum depth of 2.13 (5.40 cm)ordouble gang or 4'(10.61 cm)square electrical box.You can also use the optional(System Sensor' PN OG TR) trim ring if the station is being semi-flusli IT-wonted - -- -1, [ PUSH IN PULL DOWN i Honeywell - .1. 0 Z.',',1s,;', a SK-PULL-DA EFATUPTS F). BENE7ITS • Installer can open • Key operated test and • Meets the Americans • Reliable analog • Handle latches in station without reset lock using lock with Disabilities Act communications for down position and the causing an alarm plate actuator Accessibility trouble-free operation word Activated appears,clearly Key matches condition Guidelines(ADAAG) • Braille text on station • indicating the station controls and operating • Dual-color LED is compatible FACP mechanismshandle has been pulled visible through handle locks • Rotary address guidelines(Section • Ul..Listed,including of station blinks green • Meets ADA 4 1 3[1,3il switches for fast to indicate normal installati on UL 38,Standard of requirement for 5 lbs operation and remains . Shell,doer,and handle Manually Actuated maximum pull force to Signaling System molded from durable steady red in an alarm active condition LEXANC • CSFM listed • MEA Listed SK-PULL-SA / SK-PULL-DA Technical Specifications For a complete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Dimensions:5.5"H x 4"W x 1.45°D(14 x 10.2 x SK-Putt-SA:Single Action Pull Station 3.7cm) Microsoft,Windows,and SK-Pull-DA:Dual Action Pull Station the Windows Logo are Housing Material:LEXAN polycarbonate resin registered trademarks Bi-Colored LED: ACCESSORIES or b ademarks of Blinking Green:Normal BG-TR:Optional trim ring. Microsoft Corporation. Steady Red:Alarm SB-I/0:Surface backbox,indoor/outdoor. Silent Knight",Systern Switch:Single pole.single throw(SPST)normally *Unless otherwise noted,specifications apply to Sensor'and Honeywell' open(N/O)switch which closes upon activation of SK-Pull-SA and SK--Pull-DA are registered the pull station trademarks of Honeywell COMPATIBILITY International,Inc. ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage:15-32VDC compatible with the following Honeywell Silent intended to be used for SLC Standby and Alarm Current:350µA Knight fire alarm control panels: installation purposes.We 6820:Addressable fire alarm control panel try to keep our product Wire Gauge:Up to 12AWG(3.1 mm2) information up-to 6820EVS:Addressable fire alarm control panel date and accurate.We ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature:3212F-120ff(02E- 6808:Addressable fire alarm control panel applications or anticipate 49 ;) 6700:Addressable fire alarm control panel all requirements.Alt specifications are subject Humidity:10%--930/o non--condensing 5700:Addressable fire alarm control panel to change without notice. 5808:Addressable fire alarm control panel For Technical Support, 5820XL:Addressable fire alarm control panel call 800-446-6444, 5820XL-EVS:Addressable fire alarm control panel with an emergency voice system • • For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 350135 I Rev E 111/17 - 111611 SILENT 800-328-0103 ©2017 Honeywell International Inc KNIGHT