Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Report
FP5 2022. - 0013 Lt ADT Commercial 9350 S.W. Nimbus Ave RECEIVED Beaverton, OR 97008 503-235-4000 OCT 24 2022 CITY OF TIGARD BUILDING DIVISION Reference: Fire Alarm System Trader Joes T.I. at Tigard Towne Square 16200 S.W. Pacific Hwy Tigard, OR 97224 Device Data Sheets August 2022 Honeywell I FarenhytT' Series THE POWER OF CONNECTED IFP-300 / IFP-300B Intelligent Fire Alarm Control Panel The IFP-300(red)and IFP-300B(black)are intelligent analog/addressable fire alarm control panels(FACP)and are direct replacements for the IFP-100 FACP.The IFP-300 panel contains one built-in signaling line circuit (SLC),which can support 159(IDP/SK)System Sensor''sensors and 159 IDP/SK modules or 127(SD)Hochiki'devices per loop.Additional SLC loops can be added using the model 6815 SLC expander for SK/IDP devices to increase the overall point capacity to a maximum of 300 points per panel, or model 5815XL for SD devices to increase the overall point capacity to a maximum of 254 points per panel. The IFP-300 has the interconnection capability for up to 32 panels.The system has two modes of operation,multiple panels covering one larger building,or multiple independent buildings.The SK-NIC Network Interface Card is used to network panels together.Copper wire or fiber optic cable Fr' 3008 panel connectivity can be used within the same networked system. IFP-300 has a built-in dual phone tine,digital alarm communicator/ transmitter(DACT)with IP and optional cellular technologies,form-C trouble relay,and two programmable form-C relays.The IFP-300 has powerful features such as detector sensitivity,day/night thresholds,drift compensation,pre-trouble maintenance alert,and calibration trouble alert. The IFP-300 supports a variety of devices,including RA-2000,PA-1000 or RA-100 remote annunciators,5824 seriaVparallel printer interface modules (for printing system reports),RPS-1000 power modules,and IDP,SK,or SD devices. FEATURES & BENEFITS • Network support for • Can be surface or • Network card allows • JumpStart°auto • Supports Class B up to 32 Sites flush mounted copper network programming feature (Style 4)and Class A • Built-in support for up • Built-in USB interface connection with a for easy (Style 6 or Style 7) te1591DP/SK for convenient and multi-mode or single- programming configuration for SLC, detectors and 159 quick programming mode fiber • Supports up to four and SBUS IDP/SK modules or connection option SWIFT'wireless • Built-in NAC • Firmware can be 127 SD SLC devices upgraded in the field • Built-in duaL phone gateways.Each synchronization for • Four line LCD display line,digital alarm gateway can have up devices from with 40 characters per communicator/ to 49 wireless devices AMSECO'.Gentex". line transmitter(DACT) System Sensor',and with IP and optional Wheelock' • Available in a red or cellular technologies black cabinet IFP-300 Technical. Specifications PHYSICAL: ORDERING INFORMATION Ftexput',JumpStart`. Overall Dimensions:26.4"H x 16.4'W x 4.11"D IFP-300:Intelligent Fire Alarm Control Panel.Red Honeywell",System Weight:45 lbs. Cabniet. Sensor and SWIFT are Color:Red or Black IFP-3008:Intelligent Fire Alarm Control Panel and Farenhyt"'is a Black Cabinet. trademark of Honeywell ENVIRONMENTAL International.Inc. Operating Temperature:32°F to 120°F (0°C to SBUS ACCESSORIES 49°C) RA-2000,RA-1000,RA-1000R,RA-100, Arnseco"is a registered trademark of Potter Electric Humidity:0 to 93%relative humidity(non- RA-2000GRAY:Remote annunciators Signal Company,LLC. condensing) 6815:Signal Line Circuit(SLC)Expander for IDP or Gentex°is a registered SK devices trademark of Gentex ELECTRICAL: 5815XL:Signal Line Circuit(SLC)Expander for SD Corporation.Hochiki"is a IFP-300 Primary AC:120VAC Ce 60 Hz,3.3A Total devices registered trademark of Accessory Load:6A 24VDC power-limited RPS-1 Whhee000:Power Supply Heeioi Corporation. lock"is a trademark Standby Current:190mA 5496:NAC Expander of Cooper Technologies Alarm Current:250mA 5824:Serial/Parallel Module Company_ Battery Charging Capacity:17 to 55AH 5880:LED I/O Module This document is not Battery Size:18AH max.allowed in control panel 5865-3 or 5865-4:LED Annunciator intended to be used for cabinet.Larger capacity batteries can be housed in 5883:Relay Interface installation purposes.We RBB accessory cabinet ry to keep our product information up-to MISCELLANEOUS ACCESSORIES date and accurate.We AGENCY LISTINGS AND APPROVALS HFSS:Software Suite.Provides programming, cannot cover all specific NFPA 13,NFPA 15,NFPA 16,NFPA 70,&NFPA upload/download and event reporting applications or anticipate 72:Central Station;Remote Signaling;Local RBB:Remote Battery Box Cabinet.Use for backup all requirements.All Protective Signaling Systems;Auxiliary Protected batteries up to 35 AH.Dimensions:16'Wx 10"H x to changeiwit are subject e. Premises Unit;&Water Deluge Releasing Service 6"D to change without notice. UL Listed:S2766 SK-SCK:Seismic Compliance Kit For Technical Support, CSFM:7165-0559:0504 SK-NIC:Network Interface Card Please call 800-446-6444. FDNY:COA#6245 SK-NIC-KIT:Installation Accessory Kit FM approved SK-FML:Fiber-Optic Multi Mode. transmitter and receiver APPROVED RELEASING SOLENOIDS SK-FSL:Fiber-Optic Single Mode Asco T8210A107 24 VDC 3 A max 0 Hz CELL-MOD:Cellular Communicator in Plastic Asco 8210G207 24 VDC 3 A max 0 Hz Enclosure CELL-CAB-SK:Cellular Communicator in Metal Enclosure with lock and key COMPATIBLE DEVICES See the data sheets listed below for a complete listing of the IDP,SK,SWIFT or SD devices. 350361:IDP Device Protocol data sheet 53623: SK Device Protocol data sheet 350360:SD Device Protocol data sheet 350615&350617: SWIFT devices data sheet Honeywell Farenhyt 12 Clintonville Road Northford,CT 06472 800-328-0103 3www.fdrenhyt.corn 20t8 Honneyww C I e/19 Honeywell 018 ell International Inc. Fire. Commercial Fire Alarm Cellular &/or IP StarLink COMMERCIAL FIRE CELLULAR&IP Fire Alarm .�iii Communicators • Universal full event sole&dual path cellular&/or IP UL and NFPA 72 Fire Code-Compliant,the StarLink commercial fire alarm reporting from any panel brand, Series Wireless Commercial Fire Alarm Sole Path&Dual virtually anywhere Path Communicators provide universal support for any brand 12V to 24V fire alarm control panel,reporting in • Code-compliant,replaces 2POTs lines per FACP saves Contact ID and 4/2. With broadest Verizon LTE coverage thousands of dollars per year over the leased landlines footprint available,via most extensively deployed LIE CAT1, • Supports 12V-24 control panels and FACPs that using proven StarLink circuitry,they are also available communicate using Contact ID and 4/2(such as on legacy in mercantile locking metal models.All provide the most economical solution for easy,versatile installation.Also panels),as primary or backup regional compliances,i.e.,CSFM, NYCFD,LAFD and more. • Full data Reporting to any Central Station nationwide, Easy,Universal Installation at Every Application;Panel- via Verizon® LTE Network,"The Nations largest and most powered Technology'''.StarLink Fire Communications are reliable LTE network.Rated#1 overall network, proven to easily connected to any panel or Fire Alarm Control Panel deliver consistently fast speeds ad i more places than any (FACP)standardly operating between 12V and 24V.Flexible other network"t in any application,StarLink Fire also comes in standard,or • Communicate critical life and safety alarm reports on Mercantile Models in metal housings,with code-compliant LTE(Long Term Evolution)10+year life,cyber-protected supervision,and choice of power options,Panel-Powered multi-billion dollar cellular network,for maximum life Technology'"(powered by the panel),or direct-connect 120VAC models.Signal Boost circuitry&dual diversity safety&liability protection antennae for maximum signal acquisition&null avoidance, • Easiest installation,powered by panel, NO extra power receiving signals simultaneously on both antennae. supply, NO conduit,self supervised on 4 wires Flexible Performance&Reporting Options.StarLink • Over-the-Air Upgradeable Communicator Firmware. Fire provides full data reporting,in sole and dual path,as Remote ability for critical/mandatory updates,without a a primary or backup,to any central station of your choice, truck-roll without requiring any special equipment on premises. Ultra-affordable plans are available to meet various codes • Cost-saving models and plans for any code requirement. and requirements,with supervisory check-ins from 200 Substantial savings over monthly dedicated landline charges. seconds,to 5 minutes,to an hour.The units are very easily And,$100 saving incentive for system upgrades from old activated,plans and options are selected,and 24/7 account radios(all makes)and old POTs landlines,as well as new management is provided all through www.napcocomnet.com. installations •„by Napco StarLink, Universal Fire Alarm verizOni Communicators • Sole Path Cellular and Dual Path Cellular&/or IP Models • Choice of plans(varies by model)-check-ins from 200 seconds to 5-minutes to 1 hour,Verizon LIE Network • Patented Signal Boost'"and Dual Diversity Antennae for maximum signal acquisition&null avoidance, receiving signals simultaneously on both antennae • Money-saving Tradeup incentive credit • Bonus:Full High-Speed Napco Panel remote uploading/downloading • COMPLIANCES:NFPA72 Editions:2016,2013,2010, 2007;UL 864,9th Ed.,UL1610,UL985,UL1023, NYCFD; CSFM;LAFD StarLink 0 V! Air N FM' • Code-compliant standard or mercantile metal models(right and left,respectively). StarLink FireCommercial Fire Alarm Cellular COMMERCIAL FIRE CELLULAR& IP Fire Alarm Li Communicators StarLink Fire Specifications Ordering Information STANDARD MODELS: COMMERCIAL FIRE SOLE PATH CELLULAR& • Advanced LTE Dual Diversity Antennae for optimized DUAL PATH CELLULAR&/OR IP(•'I"MODELS):* performance SLE-LTEVI-FIRE Dual Path Communicator,Cellular&/or IP, • Durable ABS plastic housing includes three keyhole slots for connected by Verizon LTE",ABS. Low current draw,panel- mounting(for commercial application,aligns with triple gang powered technology"(powered by control panel) boxes) SLE-LTEV-FIRE as above,but sole path cellular model • Panel Powered Technology"(powered by panel),Low current SLELTEVI-CFB Commercial Fire Dual Path Mercantile model draw,71mAstandby,200mA transmit in red metal housing on LTE,Verizon LTE Network, powered • Dimensions:5-3/8"x 7-7/8"x 1-7/8"(HxWxD) directly from control panel • Weight:13.5 oz SLETEVI-CFB-PS Commercial Fire Dual Path Mercantile model • 3 LED Indicators-Green,Signal Strength;Amber-Busy/ in red metal housing, LTE,Verizon LTE Network.Direct 120VAC Activation;Red-Trouble Powered(w/provisions for backup battery/charger).Or, • Patented Signal BoosVN signal amplification circuit and high- Optional TRF12 plug-in transformer may be used,where codes gain performance antennae permit • Operating Environment:0 to 49°C(32-120°F),up to 93% ACCESSORIES: humidity(non-condensing) 'dam ' .-' Free Commercial Fire Tradeup Trifold • 12V-24V Universal FACP Support,auto-current sensing. Brochures/Mallers/Stuffers(A720)for new Support all brands communicating in Contact ID and 4/2 and existing fire accounts SLE-ANTEXT75 Optional extended antenna with - ' MERCANTILE MODELS(similar to above,with): 75'cable(new conical shape) x,.:.• . • Locking Metal Enclosure with Hinged door& 2 key-slots for SLE-ANTEXT50 As above,with 50'cable - wall mounting(LED indicators,inside) SLE-ANTEXT30 As above,with 30'cable • Dimensions: 9-5/8"x 11-3/4"x 3-3/8"D(HxWxD) SLE-DLEXT Optional,as above,for downloading,extends distance • Weight:8 lbs(max.,power supply models) to Napco panel up to 100' • Electrical Ratings for 120VAC,60Hz TRF12 Optional Plug in AC Transformer,16.5V/20VA(use is • For Models with Power Supply: subject to local code compliance) • Input Voltage: 120VAC Nominal SLE-DLCBL Optional High-Speed Napco Panel Up/download cable • Input Current:400mA maximum • Maximum Charging Current: 200mA • Electrical Ratings for+12V New! FireLink" Integrated Fire Alarm Control • For Models without Power Supply: Panel w/StarLink Fire LTE Built In • Input Voltage: 11-15VDC(power-limited output from listed Award Winning FL-FACP-LTEVS control panel) mix Firewolf 8 Zone 24V Conventional • Input Current:71 mA with peak RF transmission current of aO1 Commercial Fire Alarm Control I; Panel with onboard StarLink Fire Sole Path,Verizon LTE Cellular • Electrical Ratings for the IN 1 Burg/Fire Input: Alarm Communicator and integral menu-driven LCD annunciator,w/ • Input Voltage:9-15VDC s 4amp,24V power supply.Optionally expandable up to 32 points/zones via • Maximum Input Current:Up to 2mA from FACP NAC circuit commercial addressable,wireless or • Electrical Ratings for IN 2 and IN 3: A conventional fire devices(2 onboard NACs providing up to 4A notification • Maximum Loop Voltage:15VDC -` power).Locking,mercantile red • Maximum Loop Current: 1.2mA enclosure,(surface or flush mount') removable 16"x17"door with • Electrical Ratings for 3 PGM Outputs: 14.25"x16"base.Houses 16Ah battery backup • Open Collector Outputs: Maximum voltage 3V when active; 15V maximum when not active • Maximum PGM Sink Current:50mA mount n StarLl.1ink Fire €° • Operating Environment 0 to 49°C(32-120 F),up to 93% COMMERCIAL FIRE CELLULAR&IP humidity(non-condensing) in • 12V-24V Universal FACP Support,auto-current sensing. 333 800-645ew Ave.,4Amityville,1l6, 1-NY 1 not USA PP g 1-800 645-9445 •Fax:1-631-789-9292 NFPA' Support all brands communicating in Contact ID and 4/2 www.napcosecurity.com SOON,Staitok Fire,FreboNSignalBoosA Panel-PovvekTeMplow,,Gemini AGemii Commeroal are trademarks of Napa Verhan,LTE,et aretrademaksof their respect*companies."StarUnkdfeisful datacoverage in US km vnaINall panel brands reporting in(Mad 1)or4/2. faNdeWsonheSizlinkAadepnrenNeseeorine under htp//vmw.ruposeeAkonVONinWSarlink ade/tPromosubleitotarroloprionme LTEikspandansarebasedanthoRdtarres tVeriinnw rankings based m the Rnop/e is USNauaal Rodkme®Aept 1H2O17. ©NAPCO,NAPCO Security Technologies Inc(NASDAQ:NSSC) A7342018.9 Honeywell Farenhyt'" Series THE POWER DF CONNECTED RA-1000 / RA-1000R Remote Annunciator The RA-1000 is a remote annunciator used to operate and program IFP-series fire alarm control panels(FACP's).The RA-1000's keypad and display match the built-in annunciator of the IFP-1000 control panel. o� The remote annunciator connects to the control panel via the RS-485 • Wm seas system bus.When the system is in normal operation and has AC power,the sum 1 Power LED is lit and all other LEDs are off.The other LEDs turn on as II we alarms,supervisories,troubles,system silenced and AC power losses occur. ' �•• rr 7 INSTALLATION The RA-1000 can be surface or flush mounted.Use the optional trim ring for surface mounts.When flush mounting an electrical box is optional.If RA-1000R/RA-1000 using an electrical box,use a 4S,single-gang,or double-gang box. COMPATIBILITY The RA-1000 is compatible with the following Farenhyt Series FACPs: • IFP-2100/IFP-2100ECS • IFP-1000/ECS • IFP-100/ECS • IFP-300/IFP-300ECS • IFP-75 • IFP-50 BEN [ TS, • 80-character backlit • Initiate and end fire • Five Status LEDs for: • Support for LCD display(4 lines drills with a single key alarms,supervisory, simultaneous use of with 20 characters on press trouble silence and AC multiple RA-1000s each line) • View current status by power indications • Wiring lengths up to • Tactile/audible alarms.supervisories. • Available in red or gray 6000 ft from the feedback or troubles color FACP(depending on • R5-485 SBUS • On-board piezo • 11L listed.complies wire gauge and interface to panel sounder audibly with NFPA 72 number of devices on indicates alarms, SBUS) • Larger keypad buttons • Accepts user codes or for system reset and troubles.and fire fighter's key silence supervisories RA-1000 Technical Specifications IFP-2100 FACP For a complete listing of all compliance approvals and "-" --- certifications,please visit " - www.farenhyt.com. MIN Microsoft,Windows,and the Windows Logo are moo registered trademarks •/�!!l ortrademarks of • Microsoft Corporation. Honeywell°is a RA-1000 RA-1000 RA-1000 registered trademarks of and Farenhyt"is a Ir trademark of Honeywell • ® ® •• International,Inc. A t•= • - a v• This document is not intended to be used for installation purposes.We try to keep our product •Up to 31 RA-1000s per system for IFP-2100 or •80-character backlit LCD display information up-to IFP-2100ECS (4 lines with 20 characters each) date and accurate.We cannot cover all specific •Up to 16 RA-1000s per system for lFP3DWECS •Wiring lengths up to 6000 ft.from applications or anticipate •Up to 12 RA-1000s per system for IFP-1000, the control panel all requirements.All IFP-1000ECS,IFP-100&IFP-100ECS specifications are subject to change without notice. •Up to 8 RA-1000s per system for IFP-50 or IFP-75 For Technical SPECIFICATIONS ORDERING INFORMATION Support,Please call Dimensions:9.1"W x 7.4"H x 1.5"D(23.1W x 18.8H x RA-1000R:Remote Annunciator.Four line LCD 800-446-6444. 3.8D cm) annunciator with 20 characters per line.Red. RA-1000:Remote Annunciator.Four tine LCD ENVIRONMENTAL annunciator with 20 characters per line.Gray. Operating Temperature:32°F to 120°F (0°C to 49°C) OPTIONAL ACCESSORIES Humidity:10%to 93%relative humidity(non- 5860TR:Red Trim Ring.For surface mounting. condensing) 5860TG:Gray Trim Ring.For surface mounting. ELECTRICAL: AGENCY LISTINGS AND APPROVALS Operating Voltage:24VDC • MEA Approved Standby Current:20mA • CSFM Approves Alarm Current: 25mA Wiring Distance: 6,000 ft max.from FACP • FM Approved (depending on wire gauge and number of devices • UL listed on the SRUS) Max per System:IFP-50 or IFP-75(8);IFP-100/ ECS or IFP-1000/ECS(12);IFP-300/ECS(16); IFP-2100/ECS(31) For more information Learn more about Honeywelfs Farenhyt Series and other products available by visiting www.farenhyt.com> Honeywell Security&Fire 12 Clintonville Road Northford.CT 06472 Doc 3500711 Rev FI 12/17 Honeywell 800-328-0103 ©2017 Honeywell International Inc. Honeywell Farenhyt" Series THE POWER OF CONNECTED Intelligent Photoelectric Smoke Detector & Photoelectric Smoke with Thermal IDP-Photo. IDP-Photo-T and IDP-Photon Ate , The IDP-Photo is a photoelectric smoke detector and the IDP- Photo-T is a photoelectric smoke detector with thermal.These plug in smoke detectors,with integral communication,provide IDP-PHOTO(BASE NOT INCLUDED) features that surpass conventional detectors and are for use with the Farenhyt Series fire alarm control panels(FACPs). Compatibility The IDP-Photo.IDP-Photo-T and IDP- Detector sensitivity can be programmed from the FACP software. Photon are compatible with the following IDP series detector bases: Sensitivity is continuously monitored and reported to the FACP.Point ID capability allows each detector's address to be set with rotary address • B210LP 6"Mounting Base switches,providing exact detector locations for selective maintenance • B501 4"Mounting Base when chamber contamination reaches unacceptable levels. • 3224B1 6"Isolator Base IDP-Photo and IDP-Photo-T have a unique optical sensing chamber • B224R8 6"Relay Base that is engineered to sense smoke produced by a wide range of • B200SR 6"Sounder Base combustion sources.In the IDP-Photo T,dual electronic thermistors The IDP-Photo,IDP-Photo-T and add 135°F(57°C)thermal technology to maximize detection. IDP-PhotoR are compatible with the following Farenhyt Series FACPs: The IDP-PhotoR is a remote test capable detector for use • IFP-2100/IFP-2100ECS/RFP-2100 with the DNR(W)duct smoke detectors.It is UL 268A listed • IFP 2000/IFP 2000ECS/RPS-2000 when used with the DNR(W)duct smoke detector. • IFP-1000/IFP-1000ECS • IFP-300/IFP-300ECS Installation • IFP-100/IFP-100ECS The IDP-Photo and IDP-Photo-T plug into a compatible IDP- series detector base.The IDP-PhotoR is a remote test capable • IFP 75 detector for use with the DNR(W)duct smoke detector. • IFP-50 • Sleek,tow-profile • Superior EMI • Detector transmits • Tamper-proof feature • MEA Listed 225-02-E design resistance for signal to indicate available on mounting Vol.V • Reliable analog reliability maintenance is bases communications for • Simple field cleaning required • Listed for use in duct trouble-free operation for code compliance • Optional remote LED applications • Age resistant polymer • Variety of mounting annunciator(System • Rotary address housing options to meet any Sensor"PN RA100Z) switches for fast • Dual electronic application • Plug-in mounting installation thermistor design on • Dual LED indicators provides ease of • UL Listed the IDP-Photo-T for 360°visibility installation • FM Approved • CSFM Listed IDP-Photo, IDP-PhotoR and IDP-Photo-T Technical Specifications Fora complete listing of all compliance approvals and certifications,please visit www.farenhyt.com. canp."t,ieFAcp Microsoft.Windows,and the Windows Logo are -� - - « - registered trademarks i or trademarks of RAIOEZ(Optional) Microsoft Corporation. I 1 'I i f Honeywell e is a LIMINregistered trademark of and Farenhyf"is a / t trademark of Honeywell 3 I 1 �,�. I` .Itit International.Inc. t r i■� ��/ This document is not intended to be used for installation purposes.We I l f I try to keep our product i ..._._..._...._..__..___.., _._..__..___._......_.._...__..._...__..__ I _..__.._. ...._...... information up-to [.._..__...___...__.. ...._...._..._......_...__.._° '°a Optional.Wiring .._______...._.._..__.__.._.__ date and accurate.We cannot cover alispecific Wiring IOP•Series Detector Mounting eases applications or anticipate all requirements.All specifications are subject SPECIFICATIONS* ORDERING INFORMATION to change without notice. Physical: IDP-Photo:Photoelectric Smoke Detector For Technical Height:2.0"(5.08cm)less sensor IDP-Photo-T:Photoelectric Smoke Detector with Support,Please call Diameter:4.1"(10.4CM)installed in B501 base Thermal(135°F) 800-446-6444. IDP-PhotoR:Photoelectric Smoke Detector, ENVIRONMENTAL remote test capable,for use with ONR(W)duct Operating Temperature: smoke detector IDP-Photo:32°F-120°F(0°C-49°C) IDP-Photo-T:32°F-100°F(0°C-38°C) ACCESSORIES RA100Z:Remote LED Annunciator. Humidity.10 to 93%non-condensing) XR2B:Detector Removal Tool.A removal and ELECTRICAL RATINGS replacement tool for IDP plug-in detectors. Operating Voltage:15-32VDC Includes the T55 127 000. SLC Standby and Alarm Current:300 µA M02 04 O1:Detector Test Magnet M02-09-00:Test Magnet with Telescoping Handle OTHER RATINGS XP-4:Extension Pole for XR2B.Extends from 5- IDP-Photo-TThermal:Fixed temperature set point 15 ft. 135°F(57°C) T55-127-000:Detector Removal Head. Velocity:0-4000 fpm(0-20 m/sec)(suitable for BCK-200B:Black Detector Kit For IDP-series installation in ducts) detectors. IDP-Photo Insect Screen Hole Size:0.016"(0.41 *Unless otherwise noted,specifications apply to mm)nominal IDP-Photo and IDP-Photo For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Security&Fire 12 Clintonville Road Honeywell Northford.CT 06472 Doc 3502801 RevJ I08/17 THE POWER OF CONNECTED 800-328-0103 ©2017 Honeywell International Inc. Honeywell Farenhyt Series THE POWER OF CONNECTED Addressable Single Action and I R Dual Action Pull Stations IDP-Pull-SA & PULL lDP-Pull DA DOWN 1 V I The IDP-PulI-SA is a single action pull station requiring only one motion to activate the station.The IDP-Pull-DA is a dual action putt station requiring two motions to active the station.Both pull stations are designed to ti Hasa;wen work with Honeywell Farenhyt series fire alarm control panels(FACPs). IDP-PULL.-SA Installation The IDP-Pull-SA and IDP-Pull-DA can be surface mounted to an SB-I/O FIRE surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm)or double gang or 4"(10.61 cm) ' square electrical box.You can also use the optional(System Sensors LIPULL DOWN PUSH IN I� PN BG-TR)trim ring if the station is being semi-flush mounted. Compatibility The IDP-Pull-SA and IDP-Pull-DA are compatible -z with the following Farenhyt Series FACPs: a - • IFP-2100/IFP-2100ECS/RFP-2100 IDP-PULL-DA • IFP-2000/IFP-2000ECS/RPS-2000 • IFP-1000/IFP-1000ECS • IFP-300/IFP-300ECS • IFP-100/IFP-100ECS • IFP-75 • IFP-50 • Installer can open • Key operated test and • Meets the Americans • Reliable analog • Handle latches in station without reset lock using lock with Disabilities Act communications for down position and the causing an alarm plate actuator Accessibility trouble-free operation word Activated condition Guidelines(ADAAG) appears.clearly • Key matches • Braille text on station • Dual-color LED is compatible FACP controls and operating handle indicating the station visible through handle locks mechanisms has been pulled guidelines(Section • Rotary address of station blinks green , Meets ADA 4.1.3[13]) switches for fast • UL Listed,including to indicate normal UL 38.Standard of requirement for 5 lbs installation operation and remains • Shell.door,and handle Manually Actuated maximum pull force to steady red in an alarm active molded from durable Signaling System condition LEXAN • CSFM Listed • MEA Listed IDP-Pull-SA and IDP-PUtt-DA Technical Specifications Fora complete listing of all compliance approvals and certifications.please visit www.farenhyt.com. Clow Microsoft,Windows,and the Windows Logo are Gass e registered trademarks I or trademarks of cenpam.r>GP `" ( Microsoft Corporation. r I.• ::• Honeywell and r System Sensor'are • registered trademarks • of and Farenhyt'is a Clax.AWlam;,Map:„_ trademark of Honeywell International,Inc. vnnng ior.vnsaa i°rrw.°n ran s,ntr,ri• This document is riot intended to be used for installation purposes.We SPECIFICATIONS* ORDERING INFORMATION try to keep our product Physical:5.5'H x 4"D(14cm x 10.2cm) !DP-Putt-SA:Single Action Putt Station information up-to Shipping Weight:5.4oz DP-Putt-DA:Dual Action Pull Station date and accurate.We Housing Material:LEXAN polycarbonate resin cannot cover all specific Bi-Colored LED: ACCESSORIES applications or anticipate all requirements.All Blinking Green:Normal BG TR:Optionaltrim ring. specifications are subject Steady Red:Alarm SB-I/O:Surface backbox,indoor/outdoor. to changewithout notice. Switch:Single pole,single throw(SPST)normally *Unless otherwise noted,specifications apply to For Technical open(N/O)switch which closes upon activation of IDP Pull SA and IDP Pull DA Support,Please call the pull station 800-445-6444. ELECTRICAL RATINGS Operating Voltage: 15-32VDC SLC Standby and Alarm Current:350pA Wire Gauge:Up to 12AWG(3.1 mm2) ENVIRONMENTAL Operating Temperature:32°-120°F(0°C-49°C) Humidity:10 to 93%non-condensing) • For more information Learn more about Honeywells Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Security&Fire 12 Clintonville Road Honeywell NOrthford,CT 06472 Doc 3502861 Rev H 108/17 THE POWER OF CONNECTED 800-328-0103 02017 Honeywell International Inc Honeywell THE POWER OF CONNECTED Farenhyt' Series IDP-MINIMON Addressable Monitor Module The IDP-MINIMON is a compact and lightweight addressable monitor s module for use with Honeywell Farenhyt Series fire alarm control panels (FACPs).The IDP-MINIMON acts as an interface to contact devices,such as waterflow switches and pull stations. The IDP-MINIMON supports Class B supervised wiring to the load device. `� � Conventional 4-wire smoke detectors can be monitored for alarm and �6 trouble conditions. INSTALLATION The IDP-MINIMON can be mounted in a single gang junction box directly IDP-MINIMON behind the monitored device.Its small size and light weight allow it to be installed without rigid mounting requirements. COMPATIBILITY The IDP-Minimon compatible with the following FarenhytSeriesFACPs: • IFP-2100/IFP-2100ECS/RFP-2100 • IFP-2000/IFP-2000ECS/RPS-2000 • IFP-1000/IFP-1000ECS • IFP-300/IFP-300ECS • IFP-100/IFP-100ECS • IFP-75 • IFP-50 I 1 , ' • Single contact monitor • Rotary address • ULApproved • Small and lightweight swllches for fast • CSFM Listed size allows for flexible installation • MEA Listed 457-99-E mounting options • Arising Vol.V • Support for Class 6 communications wiring • Fully supervised • IDP-MINIMON Technical Specifications For a complete listing of all compliance approvals and PHYSICAL ORDERING INFORMATION certifications.please visit Dimensions:1.3"H x 2.8°W x.5"D(3.3 x 7x 1.3 cm) IDP-MINIMON:Mini monitoring module www.farenhyt.com. Shipping Weight:1.2oz(37 g) Microsoft,Windows,and the Windows Logo are ENVIRONMENTAL registered trademarks Operating Temperature:32°F-120°F(0°C- or trademarks of 49oC) Microsoft Corporation. Humidity:10 to 93%non-condensing) Honeywell°and System Sensor"are ELECTRICAL RATINGS registered trademark of and Farenhyt'"is a Operating Voltage:15-32VDC trademark of Honeywell SLC Standby and Alarm Current:350µA International,Inc. End-of-Line Resistance:47K S2 This document is not Initiating device circuit wiring resistance:1,500E2 intended to be used for max installation purposes.We SLC loop resistance:40S2 max. try to keep our product Wire Length:6'min. information up-to date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For Technical Support,Please call 600-446-6444. For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Security Si Fire 12 Clintonville Road Honeywell Northford,CT 06472 Doc a5oz7sl Rev HI 08/17 THE POWER Or CONNECTED 800-328-0103 ©2017 Honeywell International Inc. Honeywell Farenhyt" Series THE POWER OF CONNECTED Addressable Dual Monitor Module =1 � IDP-Monitor-2 The IDP-Monitor-2 is an addressable monitor module with two r• initiating circuits for use with Honeywell Farenhyt Series fire alarm control panels(FACPs).The IDP-Monitor-2 acts as an interface to contact devices,such as waterftow switches and pull stations. IDP-MONITOR-2 The IDP-Monitor-2 supports Class B supervised wiring to the load device.Conventional 4-wire smoke detectors Compatibility can be monitored for alarm and trouble conditions. The IDP-Monitor-2 is compatible with Because the IDP-Monitor-2 is capable of monitoring two separate Class B the following Farenhyt Series FACPs: circuits,it is ideal for waterfiow tamper switch and flow switch monitoring. • IFP-2100/IFP-2100ECS/RFP-2100 • IFP-2000/IFP-2000ECS/RPS-2000 Installation • IFP-1000/IFP-1000ECS The IDP-Monitor-2 mounts directly into a 4"square electrical box.The • IFP-300/IFP-300ECS box must have a minimum depth of 2-1/8".A surface mount electrical • IFP-100/IFP-100ECS box(System Sensor°PN SMB500)is available from Honeywell. • IFP-75 • IFP-50 • • Monitor two circuits, • Attractive ivory cover with unique plate addresses, • Rotary address simultaneously switcnes for fast • Support for Class B installation wiring • SEMS screws for easy • Fully supervised wiring • Panel controlled • UL Listed status LED that • CSFM Listed flashes green in normal state and is • MEA Listed 457-99-E solid rod in alarm Vol.V IDP-Monitor-2 Technical Specifications For a complete listing of all compliance approvals and certifications,pleasevisit TO NEXT (-) (-) www.farenhyt.com. DEVICE (') (.) FROM PANEL OR TWO INITIATING DEVICE CIRCUITS(L&H),EACH MONITOR `' PREVIOUS DEVICE Microsoft,Windows,and POWER LIMITED TO 240 µA l 11 VDC MAX. - MODULE i the Windows Logo are , registered trademarks 47k EOL • �= � CONNECT MODULES TO LISTED or trademarks of RESISTOR A •' I_) COMPATIBLE MODULES PANELS ONLY Microsoft Corporation. lob�L w �_, SIGNAL LINE CIRCUIT(SLCI Hone and 32 VDC MAX. Systemm Sen Sensor"are 47k EOL ir �- TWISTED PAIR IS RECOMMENDED registered trademarks RESISTOR f of and Farenhyf"is a ���� trademark of Honeywell ALL WIRING SHOWN IS International,Inc. UL LISTED CONTACT CLOSURE DEVICES MAY SUPERVISED AND POWER LIMITED BE USED.DO NOT MIX FIRE ALARM INITIATING, This document is not SUPERVISORY,OR SECURITY DEVICES ON THE L SAME INITIATING DEVICE CIRCUIT MONITOR (TERMINALS 6 8 7)RESPONDS AT ADDRESS intended to be used for SET ON CODE SWITCHES.MONITOR H(TERMINALS 88 installation purposes.We INSTALL CONTACT CLOSURE DEVICES PER 9)RESPONDS AT NEXT HIGHER ADDRESS. try to keep our product MANUFACTURER'S INSTALLATION INSTRUCTIONS. information up-to date and accurate.We cannot cover all specific applications or anticipate Typical Wiring for I DP-Monior-2 Module,NFPA Style B all requirements.All specifications are subject to change without notice. For Technical Support,Please call SPECIFICATIONS" ORDERING INFORMATION 800-446-6444. Physical:4.5"H x 4"W x 1.3 D(11.4 x 10.2 x 3.2cm) IDP-Monitor-2: Dual Monitoring Module Shipping Weight:6.3oz(196g) ACCESSORIES ELECTRICAL RATINGS SMB500:4"Square Surface Mount Electrical Box Operating Voltage: 15-32VDC Maximum Current Draw:6.4mA(LED on) SLC Standby&Alarm Current:750pA max t 24 VDC(one communication every sec with 47k EOL) End of Line Resistance:47k0 ENVIRONMENTAL Operating Temperature:32°-120°F(0°C-49°C) Humidity:10 to 93%non-condensing) For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Security&Fire 12 Clintonville Road Honeywell Northford,CT 06472 Doc 350269 I Rev GI 09/17 THE POWER OF CONNECTED 800-328-0103 ©2017 Honeywell International Inc. Honeywell Farenhyt" Series -HE POWER OF CONNECTED L-Series Indoor Horns, Strobes, and Horn Strobes The L-Series audible visible notification products offers the most versatile and easy-to-use line of horns,strobes,and horn strobes 1,40,1,0 ' in the industry with lower current draws and modern aesthetics. 10.1.1.1 ':tr, F � r � i- With white and red plastic housings,standard and compact devices,and plain,FIRE,and FUEGO-printed devices,System Sensor L-Series can meet virtually any application requirement. E _ E The L-Series line of wall-mount horns,strobes,and horn strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature plug-in designs with minimal intrusion into the back box,making installations fast and foolproof •l «kl t i while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage,the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring,so installers can test wiring continuity before the device is installed. INDOOR SELECTABLE-OUTPUT HORNS, STROBES,AND HORN STROBES FOR WALL Installers can also easily adapt devices to a suit a wide range APPLICATIONS of application requirements using field-selectable candela settings,automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. AI '.. Hf F ' I • Updated Modern • Meets DoD • Automatic selection of • Mounting plate • Compatible with Aesthetics specification 12-or 24-volt shorting spring checks System Sensor • Offers small profile requirements operation at 15 and 30 wiring continuity synchronization devices for horns and • Features a plug-in candela before device protocol horn strobes design with minimal • Uses field-selectable installation • Listed for wall • Color lens intrusion into the back candela settings on • Supports electrically mounting only attachments for use box wall units:15.30,75. compatible with with clear lens wall or • Horn rated at 88+dBA 95,110.135,185 existing SpectrAlert ceiling strobe al 16 volts • Mounting plate for all and SpectAlert • Designed with • Supports rotary switch standard and all Advance devices tamper-resistant for horn tone and two compact wall units construction volume selections L-SERIES SPECIFICATIONS ARCHITECT/ENGINEER SPECIFICATIONS GENERAL L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box,4 x 4 x 11-inch back box, 4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 1 7/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit""Module accessory,shall be powered from a non- coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110,135,and 185. STROBE The strobe shall be a System Sensor L-Series Model______listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. HORN STROBE COMBINATION The horn strobe shall be a System Sensor L-Series Model_ _listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. SYNCHRONIZATION MODULE The module shall be a System Sensor Sync•Circuit model MD L3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 2 1/8-inch back box.The module shall also control two Style Y(class 8)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. PHYSICAL AGENCY LISTINGS AND APPROVALS Wall-Mount Dimensions(including lens):5.6"L x 4.7"W x 1.25" D UL:Listed (143 mm L.119 mm W x 32 mm 0) FM:Approved Compact Wall-Mount Dimensions(including lens):5.26"Lx 3.46"W CSFM:Listed x 1.93"D(133 mm L x 88 mm Wx 49 mm D) Horn Dimensions:5.6" L x 4.7"W x 1.25" D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions:5.25"L x 3.45"W x 1.25"D(133mm L x 88mm Wx 32mm D) ELECTRICAL SPECIFICATIONS Strobe Flash Rate:1 flash per second Nominal Voltage Regulated:12VDC or regulated 24DC/FWR1 Operating Voltage Range2:8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3)Sync Module:8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge:12 to 18 AWG ENVIRONMENTAL Standard Operating Temperature:32°F to 120°F(0°C to 49°C) Humidity Range:10 to 93%non-condensing Notes: 1.Full Wave Rectifi ed(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P.S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. UL MAX HORN CURRENT DRAW(mA RMS) UL MAX STROBE CURRENT DRAW(mA RMS) SOUND PATTERN DB 8-17.5V 16-33V CANDELA 8-17.5V 16-33V DC DC FWR DC DC FWR Temporal High 39 44 54 CANDELA 15 88 43 60 Temporal Low 28 32 54 RANGE 30 143 63 83 Non-Temporal High 43 47 54 75 N/A 107 136 Non-Temporal Low 29 32 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL MAX CURRENT DRAW(mA RMS),2-WIRE HORN STROBE,CANDELA RANGE(15-115 CD) 8-17.5V 16-33V DC INPUT 15CD 30CD 15CD 30CD 75CD 95CD 110CD 135CD 185CD EMTempHi 98 158 54 74 121 142 162 196 245 EM Temp Low 93 154 44 65 111 133 157 184 235 EM Cont Hi 106 166 73 94 139 160 182 211 262 EM Cont Low 93 156 51 71 119 139 162 190 239 3.1K Temp Hi 93 156 53 73 119 140 164 190 242 3.1K Temp Low 91 154 45 66 112 133 160 185 235 3.1K Cont Hi 99 162 69 90 135 157 175 208 261 3.1K Cont Low 93 156 52 72 119 138 162 192 242 16VFWR SWITCH POSITION 15CD 30CD 75CD 95CD 110CD 135CD 185CD EM Temp Hi 83 107 156 177 198 234 287 EM Temp Low 68 91 145 165 185 223 271 EM Cont Hi 111 135 185 207 230 264 316 EM Cont Low 79 104 157 175 197 235 283 3.1K Temp Hi 81 105 155 177 196 234 284 3.1K Temp Low 68 90 145 166 186 222 276 3.1K Cont Hi 104 131 177 204 230 264 326 3.1K Cont Low 77 102 156 177 199 234 291 HORN AND HORN STROBE OUTPUT(DBA) 8-17.5V 16-33V FWR SWITCH POSITION SOUND PATTERN DB DC DC 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9 Coded High 85 90 90 10 3.1 KHz Coded High 84 89 89 L-SERIES DIMENSIONS - 3.46 H-- 1.91 ---- 3.46 --- Fora complete listing of all compliance approvals and a - ----1.25 1.25 certifications,pleasevisit 7 I,i' ,' ( www.farenhyt.com. 1!'� Microsoft,Windows,and ,� y ^: the Windows Logo are 5.27 ill t registered trademarks Ai ah' ,, a�a�r4ti�a or trademarks of &Lill 11111 . :,:,:,:,:,: Microsoft Corporation. t„ �� a eta=�� ` n /� 111� Honeywell nand ------- ,� - System Sensor are registered trademark compact Strobe rflom Strobe Compact Horn of and Farenhyt"is a trademark of Honeywell International,Inc. This document is not intended to be used for 4.70 installation purposes.We try to keep our product 1.91 —4.70 --�-{ information up-to 1.25 date and accurate.We 1.25 cannot cover all specific �1' applications or anticipate all requirements.All 5.67 5.67 specifications are subject to change without notice. 'ti tir For Technic al - •` � ! Support,Please call 800-446-6444. Strobe!Horn Strobe Horn L-SERIES ORDERING INFORMATION WALL HORN STROBES HORNS P2RL:2-Wire.,Horn Strobe,Red HRL:Horn,Red P2WL:2-Wire,Horn Strobe.White HWL:Horn,White P2GRL:2-Wire,Compact Horn Strobe,Red HGRL:Compact Horn,Red P2GWL:2-Wire,Compact Horn Strobe,White HGWL:Compact Horn,White • P2RL-P:2-Wire,Horn Strobe,Red,Rain P2WL-P:2-Wire,Horn Strobe,White,Plain ACCESSORIES P2RL-SP:2-Wire,Horn Strobe,Red,FUEGO TR-2:Universal Wall Trim Ring Red P2WL-SP:2-Wire,Horn Strobe.White,FUEGO TR-2W:Universal Wall Trim Ring,wht SBBRL:Wall Surface Mount Back Box,Red WALL STROBES SBBWL:Wall Surface Mount Back Box,White SRL:Strobe,Red SBBGRL:Compact Wall Surface Mount Back Box, SWL:Strobe,White Red SGRL:Compact Strobe,Red SBBGWL:Compact Wall Surface Mount Back Box, SGWL:Compact Strobe,White White SRL-P:Strobe,Red,Plain Note: SWL P:Strobe,White,Plain ALL-P models having a plain housing(no"FIRE SRL-SP:Strobe,Red,FUEGO marking on cover. SWL-CLR-ALERT:Strobe,White,ALERT All SP models have"FUEGO°marking on cover All-ALERT models have°ALERT°marking on cover For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Security&Fire 12 Clintonville Road Northford,CT 06472 Doc 3515741 Rev 8I 02/18 800-328-0103 ©2018 Honeywell International Inc. ■■�y■■oneQ�/��� y rYe" SYSTEM �$ SENSOR ti,. Indoor Selectable- �? ;, Output Strobes and • Horn Strobes for == Ceiling Applications System Sensor L-Series audible visible notification J products are rich with features guaranteed to cut `{ installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela The entire L-Series product line of ceiling-mount strobes and horn • Field-selectable candela settings on ceiling units: strobes include a variety of features that increase their application 15,30,75,95, 115, 150,and 177 versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING F-� LISTED APPROVED 55512 FM approved except 7125-16530504 54011 far ALERT models 7135-16530503 3057383 AVDS568-02•12/01/2017•Page 3 • L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17,8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75.95, 115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120'F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8'diameter x 2.5'high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9'diameter x 3.4'high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 Cd. • AVDS868-02.12/01/2017•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RM/ISi 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS).Ceiling Horn Strobe.Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02.12/01/2019•Page 3 L-Series Dimensions 2.4T(62.7 mm) 1.3T(34.8 mm) 6.92'dam. ,- 2.5' -�. 6.83'diam. (175,77 mm) (64 mall �1 (173 mm) - _ \ I- II'11Fr(.-- 1.____;,/ .f A0545-00 A05<6 00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box Aor ,/ CZ) 0 6 /6� S is T:=----"-''"eng'' mac, ��.a� :111;71:11p-ifilaM,f°14. "�r'.11 / j II_. + P% ( //Ai') �� :::ANf tr 1 �> ` c 1111.1111 A0404 DI AJi::l-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". STEM ®2a 17 System Sensor � J 1tr 3825 Ohio Avenue•St.Charles, IL 60174 Product specncatons subject Is mange willve notce.Von zystemsereorcorn `4 SEJtJ5 3f Phone:800-SENSOR2•Fax:630-377-6495 for current product information including the west version of this data sheet. AVOS868.02.12 01/2017