Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (2)
FIRE ALARM RECEIVED SUBMITTAL GUIDE JN 7 2013 CITY OF TIGARD OFFICE COPY BUILDING DIVISION FPS zoZ3 — 00071 TIGARD LIBRARY FACP/ANN/SLC DEVICE REPLACEMENT 13500 SW HALL BOULEVARD TIGARD, OR 97223 Prepared By: ' ERFORMANCE SYSTEMS INTEGRATION 7324 SW Durham Road Portland, Oregon 97224 info(a psintegrated.corn (503) 641-2222 Phone (503) 641-1464 Fax 5/8/2023 • SUPPLIED EQUIPMENT DEVICE MANUFACTURER DESCRIPTION 1O1000RD EST FIRE ALARM CONTROL PANEL 10-SDC2 EST FACP EXPANSION MODULE RLCD-CR EST FIRE ALARM ANNUNICATOR PANEL SIGA-OSD EST SMOKE DETECTOR SIGA-HRD EST HEAT DETECTOR SIGA-SB4 EST DETECTOR BASE SIGA-270 EST MANUAL PULL STATION SIGA-CRH EST CONTROL RELAY MODULE MFC-A EST MULTI-FUNCTION ENCLOSURE (FIRE ALARM) SIGA-UIO6R EST UNIVERSAL INPUT/OUTPUT MODULE MOTHERBOARD SIGA-MCT2 EST DUAL INPUT MODULE-UIO MOUNT SIGA-MCR EST CONTROL RELAY MODULE-UIO MOUNT 051-90 VESDA OSID BEAM DETECTOR OSI-HPW VESDA OSID EMITTER OSI-INST VESDA OSID INSTALLATION KIT SAE10 SDI FIRE RECORDS STORAGE CABINET ELK-12180 ELK 12V 18AH BATTERY ' ` V."VM:M., "- 5 r a I Buddha Fire alarm Solutions '. aI ff. ,-ts ., ,, i Intelligent Fire ,._ma al. al.. -1....a 14, ,, [] 1 P1 ass 44° :- ,g Alarm Systems ° ° - ..... -44,,. .„....i,... , „,,,,,‘, - ,,,,,,...0 i064, I01 000 )_ 1 r. FDNY ag: a�f , r, " GOA 6227 ! ll •0 , fj i S, ,, I 4;72 7165-1657 , �- 0244 x#•r +u Yt P e J•5: s�8nai li S' x`b.,Sz,' V 4 sgu �33'•- LO 03000 Overview Features EDWARDS brand intelligent life safety systems offer the power • Auto-programming reduces installation time of high-end intelligent processing in configurations that deliver • Supports Signature Series intelligent modules and detectors uncomplicated solutions for small to mid-sized applications.With • intelligent detection,electronic addressing,automatic device Combines the Signature intelligent releasing module with mapping, optional Ethernet°connectivity,and a full line of easily- Signature rnultisensor detectors for reliable fire suppression configured option cards and modules,these flexible systems offer • Electronic addressing with automatic device mapping versatility that benefits building owners and contractors alike. • Optional Ethernet port(SA-ETH)for central station monitoring service,programming,diagnostics and a variety of system reports. The i064 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses,and two Class B Notifi- • Two programmable switches with LEDs and custom labeling cation Appliance Circuits(NACs). Optional Class A device wiring is • Supports Genesis horn silence over two wires, and UL available with the use of a module. 1971-compliant strobe synchronization The iO1000 provides one Class A or Class B intelligent device • Optional multi protocol Field Server Bridge for interface loop that supports up to 250 device addresses. Loop controller o 3rd party Building Management Systems. modules may be added in combination to expand total system • Ground fault detection by module capacity in 250-point increments to up to 1,000 device addresses. • Supports up to eight serial annunciators, (LCD, LED-only, The i01000 panel includes four NACs that may be wired for either and graphic interface) Class A or Class B operation. • Can use existing wiring for most retrofit applications The RZI16-2 module adds even more capacity to i0 installations • Upload/download remotely or locally by adding up to 16 conventional device circuits and two additional • Optional USB module for local printing or programming using notification appliance circuits. This makes them an ideal retrofit the configuration utility on a technician's laptop. solution that can accommodate new intelligent detectors.as well as existing conventional devices. • Two level maintenance alert reporting • 10 Series supports a wide range of high-end features, including: Pre-alarm and alarm verification by point • Supports 10-Year Carbon Monoxide detectors • Adjustable detector sensitivity • RSeries remote annunciators • 4 x 20 character backlit LCD display • SIGA-REL Releasing Modules • Optional earthquake hardening: seismic Importance Factor 1.5 • Standalone operation • Fully integrated CO detection using Signature Series detectors with or without audible signaling • Alarm ON command manually activates alarm condition • Form C contacts for alarm and trouble. Form A for supervisory Page 1 ot8 E85001-0135 Issue 2.0 Application EDWARDS i0 Series life safety systems are powerful intelligent Perfect for retrofits solutions for small to mid-sized buildings.Advanced intelligent EDWARDS i0 Series control panels are particularly well suited to technology delivers the benefits of flexible system installation, retrofit applications. All connections are made over standard wiring no shielded cable required.This means that in most situations while clean and easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. existing wiring can be used to upgrade a legacy control panel to i0 technology without the expense or disruption of rewiring the The smart choice entire building. i0 control panels also support the ingenious Signature Series electronic addressing eliminates the tedium of RZI 16-2 Zone Module,which adds up to 16 conventional circuits setting dipswitches,and automatic device mapping ensures that and two NACs.This combination easily accommodates new each device resides on the system at its correct location. Mean- ntelling i t detection alongside existing conventional circuits, while, innovative programming allows the designer to customize raking t an superior solution in the retrofit market. the system to precisely suit the needs of the building owner. Scalable IP and Cellular Communications Reliability you can count on Optional SA-ETH module supports IP connection to a central sta- The inherent fault-tolerant characteristics of Analog/Addressable lien's Sur-Gard receiver,meeting one of the methods of communi- Technology boosts the reliability of EDWARDS fire alarm systems, cation allowed by NFPA 72 as of the 2013 Edition.Several popular When combined with 10 Series smoke and heat detectors, these third-party IP/Cellular communicators have been tested with the i0 systems deliver a level of dependability not previously available for control panels and are compatibility listed to UL864.The IP/Cellular communicators meet Non pat 2013 edition requirements for sole small to mid-sized applications.All EDWARDS systems are built to exacting reliability benchmarks. or secondary transmission paths. Using IP/Cellular communicators can reduce the cost of ownership by eliminating POTS lines. Please Clear-cut remote annunciation see the i0 control panel compatibility documentation part number Remote annunciation is a strong suit of the i0 Series fire alarm 3102353-EN for a full list of compatible communicators. systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and Signals with a difference LCD models thatprovide zone or i0 system NACs are configurable to fully support the advanced point annunciation. as well as signaling technology of EDWARDS Genesis and Enhanced Integ- common control capabilities. iO control panels also supports rity notification appliances.These devices offer precision synchro- graphic annunciation with optional RA Graphic Annunciator nization of strobes to UL 1971 standards. For Genesis devices, interface modules. Each interface provides common control and 32 LEDs. enabling this feature allows horns to be silenced while strobes on the same two-wire circuit continue to flash until the panel is reset. Flexibility built right in Two fully-programmable front panel switch/LED combinations provide A complete line of accessories • an added measure of flexibility.Their slide-in labels take the mystery 0 Series life safety systems are supported by a complete line of out of custom applications,and present a clean finished appearance. analog/addressable detectors,modules and related equipment. Consult the Ordering Information section for details. Programming and remote diagnostics Dimensions EDWARDS i0 Series life safety systems are simple to set up, yet "1 offer advanced programming features that put these small building1`°�I °'� 3j panels into a class of their own. The auto programming feature 0 T'O 0 - 3,0 j °O °7-.1 quickly gets the panel operational using factory default settings, I` I t 0 O Basic zone and point settings can be programmed through the 1 i - O 0 front panel interface,so the system is up and running in no time. I _J I 1 j O For more advanced system configuration and correlation groups •,I 1 - L 1 . D< 0 1 O ' O 08 programming, i0 Series systems interface to a PC running corn-patible i0-CU software.This option offers full system configuration • O 0 in the familiar Windows''operating environment. Connection is ! made to a laptop through the panel's optional RS-232 communi- ! i . cations port,which can also be used to connect a system printer. yu -�— Among the many innovative features of i0 Series control panels D5 �� FO9� �oT� is the optional network card. This module provides a standard i1)Surface Mounting Holes (3)Backbox with Door Attached 10/100 Base T Ethernet5 network connection that permits access (2)Semi-lush mounting Holes (4)Backbox with door and trim kit attached. to the control panel from any remote location with the correct communications protocols. The connection can be used to Panel dimensions,in(cm) r download to the panel from the i0-CU.or upload and view model o, 02 oa I oa os oe 01 oa os ... 5J 2.__. system reports using the i0-CU. ,,,1t, „ • er 36s o zzo s s o2s e2 z (71 196) 1 (2281 55.8) , 1400,1 1260) '11.1) (716) 66.6) ,.. .. _.._.. 425 2.7 ..__._- Available system reports include: Correlation groups. Device 2' 3.65 15.510 64.6 (9.6) (190) i;3978 (362) (2626. 1 as �,7 01 I i11.4) 2351) (6.8) details, Device maintenance, History, Internal status. System .Add 1-1!2 in.(3.81 cm)to D1 and D5 dimensions for trim kit.The(rim kit configuration.System status,Walk test, Dialer, and CO runtime. provides 0./5 inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. Page 2 of 8 E85001-0135 Issue 2.0 a System Layout i0l000 d Any combination of two single-or dual Signature loop modules Standard Loop: 250 points(one expansion slot) D SDC2 Expander, Loop 1 of 2. 250 points tip w 125 sensors and'125 modules per loop (one expansion t•?. i0-SDC2 Expander. Loop 2 of P. 2E0points • rip to 20,000 feet of wiring per loop 1 ` r-r` -- a _A ••w-� 2 _ ? *' * �, r Via, V 1 3"' ) I ` t Optional 10 A or 6.5 A Booster E= n Ethernet(SA-FTH)' �'�, �.'rz`, 44 ( Yt DACT/Dialer(SA-DACT) ® --- Lrf; Up to eight remote annunciators RS-232(SA-232 or SA-USB)" d J, w* Sixteen Conventional IDCs, Relays,Two Form G,one Form A # two additional NACs with RZI16-2 module Each i01000 panel has room for up to two Signature loop controller modules in any combination of single or dual 250-device loops. i01000 loops support 125 detectors and 125 modules. Panel Layout .a p • �-x f; k R f Y. N C DE T IF 'gym:,,.;' ' ..:,.. 44(9.94 sr ' j [7 .r.r. ' C7' , ^,�Loop supports up to 64 intelligent devices of any o tip to 20,000 feet of wiring. : r ': ,..._e ] r ' „ .. tea--- p- e ------ - -.__. 3 Optional 10 A or 6.5 A Booster Power Supply 1-r , r . . ... „, „ , I _ I 1 Transformer '` 2..Main AC widng block&fuse holder 3 RS-232 card connector(J3) Ethernet(SA ETH) 4 Dialer card connect on(JS) DACT,Dialer(SA-CAGY) 5 Ethernet card connector(J1) 6 Main circuit board RS-232(SA-232 or SA-USBj' - — 7 Panel backbox enclosure Relays:Two Form C.one Form A 8 Operator interface Sixteen Conventional IDCs. 9 SLC card connector(J7) two additional NACs with 10 Class A card connector(J2) Each i064 panel ships with one Signature loop R7116-2 module 11 Tie wrap mounts controller that supports 64 devices of any type. 12 LED expander connector(J6) 13 Standby batteries This panel's device capacity cannot be expanded. 'SA-E Ila supports:(1)remote connoctidty for diagnostics&programming,(2)Central station monitoring to Sur-Gard IP Receivers. --RS-232 supports:(1)Printer.(2)Programming Interface,(3)Use of Field Server Briidge(SA-FSB)for 3rd party Building Management Systems interface. Page 3 of 8 E85001-0135 Issue 2.0 Wiring & Configuration Signature device loop Auxiliary&smoke power outputs(TB3) The system provides one Signature device loop circuit with a total The control panel provides two auxiliary power TB capacity of 125 detectors and 125 module addresses.The loop outputs that can be used for powering ancillary 0 circuit is supervised for opens, shorts, and grounds. equipment such as remote annunciators and two NO wire smoke detectors. Aux 2 can be software le NC Circuit i i01000 i064 selected to operate continuously.The circuit is specifications ' supervised for shorts and grounds. Device loops One Class B or A One Class B or A loop, (2) 0 NO loop,supporting 125 supporting 64 devices of Circuit specifications detectors and 125 any kind. - --- ------ - -- -- ----- ---- modules.Expandable to ran get voltage 21.9 to 28.3 V four loops range NC ------ Resettable circuit 24 VDC nominal at 500 mA 3) Communication Maximum 20 V peak-to-peak (Aux power 2) NO line voltage — Continuous circuit 24 VDC nominal at 500 rnA. Circuit current 0.5 A max (Aux power 1) Use this circuit for powering 0 Circuit 660 total,0.5 pF, max two wire smoke detectors. impedance -----. ------- ._._.-- ----- (4) --- ----- --- ---- - Note:Any current above 0.5 amp connected to both Aux Isolators f34 maximum 1 and 2 will reduce the total available NAC power by that Signal Supported on a system wide basis(all device loops) amount. Synchronization when using a SIGA-CC1S or SIGA-MCC1S module (1)Trouble and Genesis or Enhanced Integrity notification ap- Ilances. Alarm,trouble,and supervisory relay(TB3) (2)Supervisory �izRw;, Coss p The trouble relay is normally-open, held closed, (3)Alarm ,R Co,,,w,r;„g and opens on any trouble event or when the panel is de-energized. The supervisory relay is (4)Smoke Aux LOW,SEC -1 ' FDa,e Line tnt,SEC -6' normally-open,and closes on any supervisory Pni i0 �, event.The alarm relay changes over on any .nnp Loop 1 PRI •(Sr .® alarm event. Leap Loop Leen Loop La„p tad device device Loop.re dance „e„re 0„,, 4'"" specifications Alarm Trouble i Supervisory Type Form C Form A Notification appliance circuits(TB2) 24 VDC 1 A 1 PP Voltage 24 at 1 A resistive 24 VDC at 1 A resistive i01000 control panels come equipped with four notification ap- Relay circuits cart only be connected to power-limited sources. pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous,temporal, synchronized,and coded output. _ Annunciator loop(TB4) Specifications ' i01000 i064 The control panel provides a connection for up to eight serially Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A driven and supervised remote annunciators. with SA-CLA module _ Voltage 24 VFWR specifications -- -----'---------- Circuit s Current 6.0 A total,2.5 A max. 3.75 A total,2.5 A max. Device loops Class R(Style'or Class A(Style Z( per circuit at 120/230 . -------- ----------� per circuit at 120/230 Circuit voltage 255 V VAC 60 Flz, VAC 60 Hz. Circuit current 30 rrtA max ----- annunciators ---....._....__5.0 A total, 2.5 A max. 3.0 A total,2.5 A max. Circuit Up to 8 annunciators or 4000 feel per circuit at 230 VAC per circuit at 230 VAC impedance 50 I-Iz. 50 Hz npedance l 26 ft total,0.35 ph max Fot N 15 K O.1/2 W Class B Class A Synchronization Supported system-wide Channel 1 Channel 2 Channel 1 Channel 2 + — + — + — + — rvr. ® tow, + + C 0®C I54 C C 0 0 TB4 EOLR RACL. -� Chi i IN Hi i + H1 C xti � NACI \ , - { . Annunciator Annunciator �1 Nnc_-./ 1 + <I ® Nnca - Phi IN + 31. + ( ) — mil=0 CH1 H)IN 5) rr ,x NAc-,- 71— _/."```__[-LLL + + B —.— I 0 + 0CH2N)IN — Ili CH2N11N 0CH2(-)INNALJ + EOLR ( _ 0CH2(-)IN � + a a ¢ � + Tre T% Marking Indicates output signal polarity when the circuit is active.Polarity reverses when the ciicuil is not active.Wire notification appliances accordingly.Notification appliance polarity shown in active slate. Page 4 of 8 - - E85001 -0135 - Issue 2.0 • Option Cards EDWARDS 10 Series panels are supported by a complete line RZ116-2 Remote Zone Interface Module of modules and related equipment that enhance performance and extend system capabilities.Option cards plug directly into ., ,,... the control panel main circuit board or are connected to it with a L sr ",2, 6t° 'S[ •M ribbon cable.After installation,terminals remain accessible.The cabinet provides ample room for wire routing, keeping wiring neat at all times. ,,, :a,a,if a_ V s,a r:f Ma r , Single and Dual Loop Controller Cards The iO-SDC1 is a single loop controller card that can be used with The RZI16-2 Addressable Remote Zone Interface Module is an the i064 as a replacement for the standard 64-point loop,or with addressable device that provides connections for sixteen Class B the 101000 as a 250-point expansion module. Initiating Device Circuits and two Class B Supervised Output Circuits.The inputs and outputs can be configured individually The i0-SDC2 is a 500-point dual loop controller card for the for several device types. i01000 that provides two SLC circuits.each with 125 detector addresses and 125 module addresses. It requires 18 consecutive addresses on the Signaling Line Circuit (SLC).Addresses are assigned electronically. There are no address Specifications iO-SOC1 i0-SDC2 switches to set. 101000:one loop, The RZI16-2 incorporates two 8-segment DIP switches that 250 device addresses 101000:two loops, are used to select the Alarm or Supervisory default device type Device Addresses i064:64 addresses 500 device addresses for each of the 16 IDC circuits.The module also includes one Wiring Class R or Class A 4-segment DIP switch used to select the default Relay or NAC Operating Voltage 24 VDC output device type. Device types other than the default are Operating Current Standby:55 mA Standby:45 mA accomplished through programming. (fully loaded loop) Alarm:80 mA Alarm: 70 rnA Note These ratings do not include the use of two-wve smoke modules RZI16-2 Specifications Communication ---- ----___.._._ Voltage ---------- ----___ Line Voltage Max.20.6 V peak-to-peak 24V/Aux nominal: 24 VDC Terminal Rating 12 to 18 AWG(0 75to 2.5 min`) Supervisory current: 250 mA at 24 VDC nominal Alarm Current 1000 mA Circuit Current 0.5 A max. Max total loopresistance t 66 0 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC Max total loopcapacitance 0.5[IF NACi, NAC2 nominal: 24 VDC 64 isolators maximum per loop(total both __-- ---- - --- --------- Current Isolators isolator bases and modules) Standby current Ground Fault Impedance 0 to 5 kc� ... for 4.7 k EOL(U.S.) 48 mA/circuit 32 to 120°F(0 to 49°C) Standby current for Operating Environment 0 to 93%noncondensln at 90°F(32°C) 3.9 k Ea (Canada) 5.7 mA/circuit Alarm current at nominal voltage 31.1 if circuit Relay outputs SA-ETH Ethernet Interface Card/IP Communicator Quantity 2 The SA-ETH card provides a standard 10/100 Base T Ethernet Type Hating(pilot duty) Programmable 24 VDC at 2.5 A network connection for connecting to an intranet. a local network, nput circuit wiring 25 per wire resistance or the Internet.The card sup ports is IP connectivity for monitoring services by a supervising station to meet Initiating device circuits NFPA 72 Chapter 26. The Ethernet card uses Quantity 16 r 4"+ EOL.resistor 4.7 k0(U.S.);3.9 k4 Canada the FIBRO protocol to communicate with Lone voltage 22./8 V for 4.7 kQ(U.S.) Sur-Gard System receivers(see below).The 22.08 V for 3.9 kr)(Canada) Card can be used to download configuration Alarm current 31.1 mA/channel at nominal voltage vf r 1 programming from the 10-C11 tothe panel. Alarm impedance range <680 t Trouble impedance range >5.55 kO t The Ethernet card is installed on theplasticSupervised ut , .f, output urcw[s -- assembly and connects to the main circuit EOL resistor 15 kR board via a ribbon cable. Quantity 2 Short circuit detection <2.6 kO SA-ETH specifications Open circuit detection >61.9 kG Ethernet 10/100 Base T Contact ratings 24 VDC at 2.5 A(5 A for two NACs) Operating environment Compatible cabinets MFC A,101000 APS Temperature 32 to 120°F(0 to 49`C) Humidity 0 to 93%RH,noncondensing al 90°F(32°C)Compatible Sur-Gard Receivers SG-System I, II,Ill, IV and 5 Page 5 of 8 E85001-0135 Issue 2.0 • SA-DACT Dialer SA-232 RS-232 interface The SA-DACT provides communications between the control The SA-232 card provides an RS-232 panel and the central station over a telephone line system. It interface with i0 panels. It can be used transmits system status changes(events)to a compatible digital for connecting a printer to the control iii,ialarm communicator receiver over the public switched telephone panel to print system events.The card `_`i' network.The dialer is capable of single, dual,or split reporting also can be used for connecting a i)I,' of events to two different account and telephone numbers.The computer to download a configuration lII t .l modem feature of the SA-DACT can also be used for uploading program from the i0-CU to the and downloading panel configuration, history,and current status control panel. flee* to a PC running the i0-CU. The RS-232 card is installed on the 31 ,,,,.,„, Ph The dialer phone lines connect to connectors plastic assembly and connects to the °» on the dialer's main circuit hoard.Phone line main circuit board via a ribbon cable. 1 connects to connector J4 and phone line 2 .w connects to connector J1. SA-232 specifications Operating voltage Standard FIA 232 Cr Terminal rating 12 to18 AWG(0.75 to 2 5 sq mm) ` The SA-DACT queues messages and Operating environment ;" transmits them based on priority(alarm, Temperature 32 to 120°F 0 to 49°C ^�t�: P l 49°C) fib, supervisory,trouble,and monitor).Activa- Humidity 0 to 93%RH noncondensing at 90°F(32`C) tions are transmitted before restorations. 'Pg i"°.O i The SA-DACT is installed on the plastic assembly and connects to the main SA-CLA Class A Module(i064 only) circuit board via a ribbon cable. The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return SA-DACT specifications wiring.The card is required for annunciator Class A wiring even Phone line type One or two loop start lines on a public, though this wiring does not return to the SA-CLA card.The SA- switched network CLA is compatible with i064 control panels only. 01000 panels Phone line connector RJ 31/38X(C31/38X) are Class A Ready. The SA-CLA is installed directly to the control Communication formats Contact ID(SIA DC.05) panel circuit board using its plastic standoffs and plug connection. Operating environment Temperature 32 to 120°F(0 to 49°C) SA-CLA specifications Humidity 0 to 93%RH, noncondensing at 90°F O - - -- -- ------- Operating voltage 24 VFWR ------- ------ ---- — Operating current 3.75 A FWR total at 120/230 VAC 60I Iz 3.0 A FWR total at 230 VAC 50 Hz Compatible DACRs __—__- _ _ 2.5 A max per circuit Receiver Models Formats impedance- " __.._.__,,,,__ „_,___ _ _Cucud _ ohms,0 35uF Terminal rating 12 tot 8 AWG(0.75 to 2.5 sq mm) Ademco 685 Contact ID -�� —���� ------ _--� FBII CP229 Contact ID — en Operating environment Osborne-Rottman OH 2000 Contact ID Temperature 32 to 120°F(0 to 49`C) Bosch D6500 Contact ID Humidity 0 to 93%RH.noncondensing at 90"F 132°C) Silent Knight 9800 Contact ID - --- Sur-Gard SG-MLR1, MLR2 Contact ID D16L-iO LED Display Expander(i01000 only) The D16L-iO LED Display Expanders provide LED annunciation for up to 16 zones. It provides two LEDs for each zone.Iwo D16L-iO The SA-USB Interface Card LED display expanders can be installed in each i01000 panel. The SA-USB Interface Card provides a USB connection to a sup- ported printer or a connection to a PC.The card can be used for (3) tat connecting a printer to the control panel to print system events. zone 1 m , � OILED 1 (2)—1- (21 --'_- The card can also be used for uploading and downloading panel WHIM ;21 LED 2 configuration. historty.and current status to a PC running the iallani Li1111111.1 ,i LED Expander I • configuration utility(CU). i 41 LED Expander 2 i, Alarm non darn SA USB specifications o- hle zone;.CD:; oar Id DC Corr t Sl h / 2D n o ` Current Slandh /Alarm 13 mA,max 20mA Universal Serial Bus 1 USR Type A host port J3(printer connection) rIlliiini ,: MIN (USB)ports 1 USB Type B device port J4(CU connection) ( 11 Supported Printer P 1 1 S ' Lanni Printer Printer communication .( VOSI._ -.� (zone 29) heed 9600 baud K� AMP Operating environment M IMMO Temperature 3210 120`F(0 to 49°C) -nib. Humidity 0 to 93%RH,noncondensing Page 6 of 8 E85001-0135 Issue 2.0 Specifications i064 i01000 Device loops 1 loop Class B or Class A(Styles 4 6.7)supporting up to 1 loop,expandable to 4,Class A or B(Styles 4,6,7), 64 device addresses(any combination of detectors and each loop supporting up to 250 device addresses(125 modules) detectors and 125 modules max.).Addresses 1 to 125 are Maximum T-taps:63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance i 2 Class B(Style Y),Class A(Style Z)optional 4 Class B(Style Y)or 2 Class A(Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max.per circuit i 2.5 A FWR each max. per circuit Primary power 120 VAC,60 Hz, 1.3 A max. 120 VAC:60 I lz,2.0 A max. 230 VAC,50-60 Hz,0.62 A max i 230 VAC.50-60 Hz,0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 rnA Input zones 16 max. 32 max. Remote annunciator (8 drops max.,RS-485 Class B,Class A is optional 8 drops max.,RS-485 Class A or B 1 Data line length:4,000 ft.(1,219 rn) Data line length:4,000 tt.(1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1:500 mA,24 VDC(1 A possible if you reduce total available NAC power by 500 mA) circuit Aux power 2:500 mA,24 VDC Output:28.3 to 21.9 VDC,special application Note:For a list of compatible devices,see the i064 and iO1000 Series Compatibility List(P/N 3102353-EN) Loop circuit , Maximum loop resistance:66 0 i Maximum loop capacitance:0.5 uF Communication line voltage:Maximum 20.6 V peak-to-peak Operating current(fully loaded loop)Stand by:55 mA/45 rnA Alarm: 125 mA/115 mA(not including two-wire smoke modules) Circuit current:0.5 A Max.Style 4, 6,and 7 wiring Max. resistance between isolators:Limited only by overall wire run lengths 64 isolators maximum per loop(total both isolator bases and modules) Batteries Type:Sealed lead acid Voltage:24 VDC Charging current:2.47 A max.Amp hour capacity:26 Ah Standby operation:24 hour or 60 hour Placement:Up to two 10 Ah batteries will fit in the i064 control panel cabinet and two 18 Ah batteries will fit in the i01000 control panel cabinet. If larger batteries are required,use an EDWARDS battery cabinet. SA-DACT dialer Phone line type:One or two loop-start lines on a public,switched network Phone line connector:RJ-31/38X(COI/38X) Communication formats:Contact ID(SA DC-05) Operating current Standby/Alarm:41 mA Max.: 100 mA FCC registration number:GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number:0.1 B Ground fault impedance 0 to 5 k4 Alarm contact Form C N.O.24 VDC at 1 A(resistive load) Trouble contact Form C 24 VDC at 1 A(resistive load) Supervisory contact Form A N.O.24 VDC at 1 A(resistive load) Envi ronmental I Temperature:0 to 49`C(32 to 120 Relative humidity:0 to 93%noncondensing F) Terminal rating ? All terminals rated for 12 to 18 AWG(0.75 to 2.5 mm2) Pagel of 8 E85001 -0135 Issue 2.0 Ordering Information Part Description ""'""`"" 101000 Fire Alarm Systems .-m._ IOt UDDG four loop 101000G? Four loopinstalled.\Elsystem with one 250-point loop installed.230v,gray door. .� ID S. 101000E 2 PG Four loops stem with one 250-point loop installed.230v,gray door, Portuguese 101000E 2SP Four loop system with one 250-point loop installed.230v,gray door,Spanish. 101000E CA Four loop system one 250-point loop installed 110v,gray door, LED stress Canada. 10100.GD Four loop system one 250-point loop installed. 110v gray door,with dialer. Contact us 101900E F four loop system,one 250,point lopp 110v,gray door,LED strips,French Canada. Phone: 800-555.4497(Option 4) I01000G PG Four loop system with one 250-point loop installed. 110v,gray door, Portuguese Email: eda2:dsfire9c n co; ..-. - .. - ___ 101000E SP Four loop system with one 250-point loop installed. 110v,gray door,Spanish. Websito Pit v,.,dsfiresa`eI c ,n _ 101000R Four loop system with one 950pornt loop installed. 110v,red door. 8985 Town Center Pkwy 101000R 2 Four loop astern with one 250-point loop installed.230v,red door. Bradenton,FL 34202 1010.00RD Four loop system one 250-point 100p installed 110v red door,with dialer. SA-TRIM2 01000 Flush mount trim,black. 09021 Carrier -All Rights Reserved. i064 Fire Alarm Systems 1064E One loop system with one 64-point loop installed. 110v,gray door. 1064E 2 One loop system with one 64-point loop installed.230v,gray door 1064E? PG One loop system with one 64-point loop installed.230v,gray door,Portuguese. 1064E 2 SP One loop system with one 64-point loop installed,230v,gray door,Spanish. 1064GD One loop system,one 64-point loop installed. 110v,gray door,with dialer. 10640E One loop system,one 64-point loop installed. 110v,gray door,English Canada. 1064GL F One loop system,one 64-point loop installed. 110v,gray door,French Canada. 1064E PG One loop system with one 64-point loop installed. 110v,gray door, Portuguese. 1064G-SP One loop system with one 64 point loop installed. 110v,grpy door,Spanish_ 1064R One loop system with one 64-point loop installed 110v,red door. 1064R 2 One logy system with one 64-point loop installed.230v,red door. 1064RD One loop system,one 64 point loop installed. 110v,red door,with dialer. SA-TRIM1 i064 Flush mount trim,black Option Cards i0-SDC1 Expansion module,one 250-device loop. 10-SDC2 Expansion module,two 250-device loops,500 devices total.For i01000 only.- ' RZI16-2 Remote Zone Interface Module. 16 Class B IDCs,2 Class B Output.Includes bracket. SA"DACT _ Dual LineDialer/Modem,supports Contact ID,mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers&computers,mounts in cabinet. SA-ETH Ethernet Port. IP Communicator,mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs.Mounts in cabinet on main board i064 systems only. SA-FSB Field Server Bridge for connection to 3rd Party Building Management Systems. Supports BACnet and Modhus protocols. Mounts in the MFCA cabinet using the FSB-BRKf2 mounting plate.See separate SA-FSR datasheet E85010-0156 for additional information. SA USB RS-232 Serial port for connection to printers&computers mounts in cabinet D16L-i0-2 LED Annunciator module. 16 X 2-I ED zones(4 programmable for sup). Mounts in cabinet to right of LCD dfsplay for zones 17-32. For iO1000 only Diet i0-1 LED Annunciator module, 16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to tell of I CD display for zones 1-16.For iO1000 only. DBRY i0 2 Canada only: LED Annunciator module,two LEDs per zone,16 zones(4 alarm only. 8 supervisory only,4 alarm or supervisory).Mounts in cabinet For i01000 only. ---- DBRY,O-t Canada only:LED Annunciator module,two LEDs per zone, 16 zones(4 alarm only. 8 supervisory superytsory only,a alarm or supervisory). Mounts In cabinet For i01000 only. Accessories CTM Gfy Tie Moduli '2 gang.Connection to a local energy foe alarm box. MIC-A Multitunctlon Fire Cabinet, 6"x 14"x 3 5"-red. SIGA- Releasing Module PT-IS System Printer BC-1 Flattery Cabinet- 14.0"x 18.25"x 7.25".Holds two 12V24A batteries. BC-1 R Battery Cabinet Red. 14.0"x 18.25"x 7.25".Holds two 12V24A batteries. BC 1 EQ Seismic hardening Kt for 10 series panels. Includes battery hardening for BC 1 enclosure and components to harden panel internal components. Programming Tools 10-CU 10 Series configuration and diagnostics utility. 260097 RS232 cable,4 conductor,DB9 PC interface Page 8 of 8 E85001-0135 Issue2.0 ffil- A - Series Remote Ser r4x aa,..,.....,, o� M� xp s� au Annunciators ., dr 6 t�+ab' v t. qx,. ,. RLCD, RLCD-C, RLED, RLED-C, tI. ,tr RLED24, GCI i. ° rD4 , FDNY immi @ COA 6020 7120-7657: Overview COA 6087 0254 S3424 Features EDWARDS R-Series Annunciators are high-performance remote • LCD models feature large 4 x 20 character backlit LCD display annunciators that provide status indication and common controls • LED models provide 16 pairs of LEDs for zone annunciation for compatible fire alarm control panels, including i0-Series small analog fire alarm systems.This family of annunciators offers LCD • Available expander extends capability with 24 pairs of LEDs or LED annunciation. Models are available with and without com- • Up to two expanders may be wired to each annunciator mon controls. • Status LEDs and internal buzzer standard on all models l here are three R-Series annunciator models, plus an LED-based expander. Up to two expanders can be connected to any annun- • Common controls available for LED and LCD display models ciator.The expander includes 24 pairs of LEDs that extend the • Available keyswitch for disabling common controls capabilities of any of the annunciators. • Standard 4-inch square electrical box mounting Ali annunciator models include status LEDs and an internal buzzer. Two models have an LCD text display,and one has 16 pairs of • Class B or Class A RS485 wiring standard LEDs for zone annunciation. LCD models feature a large back-lit, • One-, two-,and three-position enclosures available four by twenty character per line,super-twist liquid crystal display. • Graphic Annunciator interface. includes common control, indi- R-Series annunciators and expanders are mounted on a standard cators and 32 LEDS 4-inch square electrical box. using the included mounting ring. • No programing required, set the address and unit receives all They can also be surface mounted in locking steel enclosures. information from panel three different enclosures are available. A keyswitch and graphic annunciator interface is available for R-Series annunciator applications.The keyswitch enables or dis- ables common controls. The graphic annunciator interface cards supports 32 LEDs and 16 switches on the graphic panel display. Page 1 of E85005-0128 Issue 1.1 Application Annunciator Wiring R-Series annunciators communicate with the FACP on the RS-485 Annunciator, Class A data riser.This can be configured for Class A or Class B commu- nication.Annunciators do not provide ground fault isolation. ACP """°"a'°' Annunciator RS 485 I L Cell(,)IN I 0CHI 1•)IN These annunciators are stand-alone units that can be powered by CH1• I78 CHI HIE 0 CR1(-I IN the FACP or by an approved power supply. a CHI(,four CHI I.)OUT CH2 Q CR1 I IOUT !J CH11 LOUT . - ISCH2 i 3CI12'f IN I 0CH21.11N- 'CH21-1N 3 CH21-1 IN L- J L_ I e -^ � TED24VOC-' 4 CH2 p)OUT a cnz()o u r SUPPLY 0CH2(-1 Our -C2(-I OUT-�dC ___ Jc °1 1 24 voc• CI.24V(-DIN 24V DIM C I L- b ry 100 .°. �J C I� 24 vpc r �24v 1—IIN 4v{-)IN Cr ""^ —7 4L J e��«M �00 2ev v Q° °L I o)- �. (o our C,z4v Pl our . ,- C_ 1°r Ci 24V(-)OUT C24VI)Our -__ �� --- 1 /GROUND ll �% 1 �Q - (T GROUND RLCp-C RIEp-C - -- - --- Annunciator, Class B 1 -I I J -r-'—__ .,: t J L__-., - Annunciamr Ann°ncialor L -1 CI- FACP r µ I L RS-085 0 CHI l•)IN �'l �, L__-M = 000 rH, IN 1.1 cHt. (, I I L�GH1(-)IN HI(-)IN L J r-- C o I I -- cHt- L: k9WnetMT M 0 GH1(.]OVT -.. nn. - ( i r. C1111-)OUT I a CHI(-I our F_Q- - _ _ _I _ 0cn2(•)m OCRz(,)IN CcR2(-IIN CH2(-)IN RLCO RI E029 LISTED 24 UDC 0CH2(+)OUT CCH2(n)OLD Features by RLCD RLCD-C RLED-C RLED24 ISUPPLY 0CH2(-)OUT 0CH21-LOUT model 24 Vac•(' - 24V(-DIN ,024V(+)IN 24 V°C-(-- 2V()IN - -�24V )O Reset ✓ ✓ ✓ - 2 - -- 29V(+)OUT 029V 1 1+I OUT AcWSiience ✓ ✓' ✓ _ (224v HOLD I ©24V 1-)our Fire Alarm ✓ ✓ ✓ _ .GROUND .GROUND SU1DBEVISOFy ✓ ✓ ✓ _ - Ground Fault ✓ ✓ ✓ -_ Trouble ✓ ✓ ✓ _ Controls Enabled ✓ ✓ ✓ Expander ........ Annunciator 1 F rsl Expander Second Expander Wesel ✓ ✓ - ., ________ __� _____ -___ -- OUT IN OUT IN OUT Signal Silence - ✓ ✓ _ -...� VI); I -_N V11 of-)? { v(-1 VI-)C I v1•). ' 6V(•) vb)C C)v1+) I V1+)Cr LCD Display ✓__ I E -F F C. _--- I/ F _._ � E EEC ---- -I-t' Lam Test ✓ ✓ ✓ C C C Ir . r.._ -_ 1 E E i2 Zone Active LEDs 16 24o p a 0 l 0 0 Zone Trouble LEDs 16 24 - U - I r, c r. 'zones 13-16 may be selected as Supervisory on 1064 1 : ' .. _.._.. .--A A)21.r. (•A A.2 1 11 1 zones 1 o 76 and 29-32 maybe selected'as Supervisory on 10100d Graphic Annunciator Interface The GCI Graphic Annunciator Driver is an interface card that connects the fire alarm control panel to the display panel of an Remote <eyswitch LED-based graphic annunciator. o, LSRA-RS The annunciator card supports 32 LEDs and 16 switches on the 8E8 SW ITCH() j T81.1 graphic panel display- It includes status LEDs and an internal KEYs•,TCH I-I - a2_1 1 , buzzer. J' ;=j. The graphic interface is supplied with snap track mounting. It is Keyswitch Specifications c, r''0 1,N, attached to a plastic mounting rail that requires two EIA panels. Maximum 5 Vdc , I he annunciator communicates with the FACP on the RS-485 voltage Maximum 200 mA _- data riser.This can be configured for Class A or Class B commu- current ,. I „ nication.The annunciator does not provide ground fault isolation. Mounting 2 1i2 in(64 mm) r 'I It is a stand-alone unit that can be powered by the FACP or by an deep 1-gang box .r t 1 .. approved power supply. Termination Screw terminals i( C)"' e Contact Normally malty open t Graphic Annunciator Interface Specifications wire ,I -- Al rm current 146 mA at 24 Vdc(with 36 LEDs ON) Standby current 36 mA at 24 Vdc(with no LEDs ON) configuration �I- � Maximum current 10 mA per LED --" � Page 2 of 4 E85005_O1 28 Issue 1.1 - 4 Annunciator Connections Annunciator Mounting Annunciator _ ANNUNCIATOR RS-485 RISER - Mounting slot o [_ ti-r r_.j c, ' �( I J11 DIP switch - -H09 1 S 88999r a RS-485 riser Remote keyswitch /---5‘ terminals terminals (` Power terminals Expander cable == \ � terminals �� Communication -c �- LEDs o (Do J 0 Expander 0 Mounting slot -t O II - //�� EXPANDER CABLE ' Expander cable _ �I - Gt-' P Expander cable 1 terminals ' 4., - terminals I O O o ° DIP switch settings \ O Switch Description and values Si to S5 The annunciator network address(in binary). Th Network The factory setting is for address 2. a dress les: ft) S66 S8 OF used (f 1(factory 2 11000 3 00100 4 - —� MOUNTINGes S6 Network OFF 9600 baud(factory default setting) C J I� baud rate ON 38,400 baud RING EXPANDER ELECTRICAL BOX Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure, surface mounted protection for annunciators and extenders. Each con- sists of a back plate, hinged cover, and key lock. - The enclosures are 16-gauge welded steel with a white, painted 6.0 in finish. Each enclosure includes a security lock and two keys.The 15.2 cm two-and three-position enclosures have wiring channels for cor- - rect routing of interconnections. - H The enclosures attach to a standard electrical box,and provide a mounting hp that takes the place of the integral mounting ring sup- O-i plied with the annunciators and expanders. 0.9 in 2.3 cm I — I i -- - - - _ . .9998 j RA-ENC1 ----.. - 9.5 in I 24.1cm f 2.Oin -- 9.8 in 1 5.1 cm 24.9 cm Dimensions(H x W x D) J i RA-ENC1 6.3x98x 2.0 in(16.Ox24.9x5.1 cm) j _- RA-ENC2 12.0x9.8x2.0in(30.5x24,9x5.1cm) --- I RAFNC3 17.7 x 9.8 x 2.0 in(45.0 x 24.9 x 5.1 cm) _.., RA-ENC3 Note:Allow approximately 2 inches(50 cm)clearance on both sides of the ___ enclosure,to permit inserting and removing the key,and opening the door RA-ENC2 through 90 degrees. Page 3 of 4 E85OO5-0128 Issue 1.1 Specifications E. DINAR RLCD-C RLCD RLED-C RLED24 Operating voltage 24 VDC,continuous. Standby current 99 mA 98 mA 28 mA 6 mA Alarm current 115 mA 113 rnA 62 mA 34 rriA Contact us RS-485 communications Class A or Class B,9600 baud Phone: 800-655 4497(Option 4) - .. is. Email: i i r ri tin� �� 2 e, Data wiring 18 to 14 AWG(1 0 to 5 sq mm)twisted pair(6 twists per foot Website: i ti irr' 'rre.n, ,r minimum). Maximum wire run is 4,000 It. (1,219 m) 8985 Town Center Pkwy Remote key switch circuit 5 VDC at 1 mA,power-limited unsupervised -- Bradenton,FL 34202 Ground fault impedance 0 _ -- ©2020 Carrier Power wiring 18 to 14 AWG(1.0 to 2.5 sq.mm)All rights reserved. Display area 4 lines of 20 characters each Dimensions(H x W x D) 5-5/8 x 8-1/2 x 1-1/2 in.(14.3 x 21.4 x 3.6 urn) Mounting North American 4-inch square electrical box or listed enclosure Agency Listing Y UL,ULC Operating environment Temperature:32 to 120`F(0 to 49°C)Humidity:0 to 93%RH, noncondensing at 90°F(32°C) Ordering Information Part Description Remote Annunciators RLCD LCD text annunciator without common controls. English. RLCD-R LCD text annunciator without common controls. English.Red. RE CDF LCD text annunciator without common controls.French. - - - - RLCD-C LCD text annunciator with common controls.English. RLCD CR LCD text annunciator with common controls. English. Red. RI.CD-CF LCD text annunciator with common controls.French. RLED C 16-pair LED zone annunciator with common controls. English RLED-CR 16-pair LED zone annunciator with common controls.English, Red. RLED-CF 16-pair LED zone annunciator with common controls. French. Remote Expanders RLED24 24-pair LED zone expander with expander cable and zone card insert. RLED24R 24 pair LED zone expander with expander cable and zone card insert Red.- - Enclosures RA-ENC1 One position enclosure for Remote Annunciator. RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander. including one interconnection cable. RA-FNC3 Three-position enclosure for Remote Annunciator and two Remote Expanders. including two interconnection cables. LSRA-SB Surface Mount Box- for single R Series annunciator Graphic Annunciator Drivers ......._._.___........ ......... . . GCI Graphic Annunciator Driver, provides outputs for common indicators and 32 alarm! supv zones as well as inputs for common switches. Provided with a snap track for mounting in custom graphic enclosures. Accessories _....... _. .. .... .. ... RKEY Remote key switch on plate for enabling or disabling common controls(Lock' Unlock). 27193-16 Electrical box,surface mount,white single-gang,for RKEY. 0 Page 4 of 4 E85005-0128 issue 1.1 Intelligent Initiating Devices a<` :, r' r` yrz ��� InteIhgent Smok Detector 4,,, 111111.ft 4111% SIGA-OSD �r•: ... .•, `\, F 12M5 ® 7272.1657: 0511 Overview Standard Features The Signature Optica Series SIGA-OSD smoke detector • Multi-criteria optical smoke sensing technology brings advanced optical(photoelectric)technology to a practical • Wide 0.5 to 4.36%/ft.(1.6 to 13.6%/m)smoke obscuration design that increases efficiency,saves installation time, cuts costs,and extends life safety and property protection • Uses Existing Wiring capabilities.Continuous self-diagnostics ensure reliability • Integrated nuisance resection reducing unwanted alarms over the long-haul,while environmental compensation helps from general cooking particulates reduce maintenance costs. • Listed to UL 268 7th edition Like at Signature Optica Series detectors,the SIGA-OSD is an intelligent device that gathers analog information from multiple • Automatic Device Mapping optical sensors, converting this data into digital signals. Utilizing • Up To 250 Total Signature Addresses Per Loop dual optical wavelengths combined with multiple detection angles, the SIGA-OSD differentiates particles that are not representative • Two Levels of Environmental Compensation of actual smoke. Particle data is input into digital filters which • Two Levels of Dirty Detector Warning feed a series of ratios removing signal patterns that are typical of • Twenty Pre-Alarm Settings nuisance sources,thus reducing unwanted alarms.To make an alarm decision,the detector's on-board microprocessor measures • Five Sensitivity Settings and analyzes all optical sensor readings and compares this • Non-Volatile Memory information to preprogrammed settings. • Electronic Addressing • Automatic Day/Night Sensitivity Adjustment • Bicolor(Green/Red)Status LED • Standard, Relay, Fault Isolator, and Audible Mounting Bases • Sensor Markings Provide Easy Testing Identification Note:Some features described here may not be supported by all control systems.Check your control panel's Installation and Operation Guide for details. Page i of 4 ...____ E85OO1-1 001 L v Issue 1.4 • Application Testing & Maintenance The SIGA-OSD detects particles from a wide range of combustion Each detector automatically identifies when it is dirty or defective sources and will trigger an alarm when smoke density in the and causes a "dirty detector"message.The detector's sensitivity chamber reaches preprogrammed level.Thanks to its high- measurement can also be transmitted to the loop controller. performance reflective response technology. the smoke sensor A sensitivity report may be printed to satisfy NFPA sensitivity responds quickly and reliably to a wide range of fire types, measurements, which must be conducted at the end of the first including both fast and slow burning fires fueled by combustibles year and every two years thereafter. typically found in modern multi-use buildings. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors Compatibility may be turned off temporarily from the control panel.Availability of maintenance features is dependent on the fire alarm system used. The SIGA-OSD detector is compatible only with control panels using a Signature Loop controller. Accessories Installation Detector mounting bases have wiring terminals that are accessible from the"room-side"after mounting the base to the Signature Series detectors mount electrical box. The bases mount to North American 1-gang boxes to North American 1-gang boxes .' and to 31/2 inch or 4 inch octagon boxes, 1 Y inches(38 mm) 3-1/2 inch or 4 inch octagon deep.They also mount to European BESA and 1-gang boxes with boxes, and to 4 inch square °"""" 4'r' 60.3 mm fixing centers.The SIGA-SB4, SIGA-RB4, and SIGA-IB4 electrical boxes 1-1/2 inches 2J mount to North American 4 inch sq. electrical boxes in addition to (38 mm)deep.They mount to the above boxes.They include the SIGA-TS4 Trim Skirt,which is European BESA and 1-gang r used to cover the"mounting ears"on the base. The SIGA-AB4G t.r boxes with 60.3 mm fixing � ;�� E,,,,,,;Cb,er mounts to a 4 inch square box only. centers. See mounting base installation and wiring for more information. // g Sensing and reporting technology SIGA-AB4G/T/LF SIGA-SB SIGA-IB SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED The microprocessor in each detector provides additional benefits-Self-diagnostics and History Log,Automatic Device Remote LED SIGA-LED-The remote LED connects to the Mapping, and Fast,Stable Communication. SIGA-SB or SIGA-SB4 Standard Base only. It features a North Self-diagnostics and History Log - Each Signature Series American size 1-gang plastic faceplate with a white finish and detector constantly runs self-checks to provide important red alarm LED. maintenance information.The results of the self-check are SIGA-TS4 Trim Skirt-Supplied with 4 inch bases, it can also automatically updated and permanently stored in the detector's be ordered separately to use with the other bases to help hide non-volatile memory surface imperfections not covered by the smaller bases. Automatic Device Mapping -The loop controller learns where Sounder Bases- Signature Series sounder bases are designed each device's serial number address is installed relative to other for use where localized or group alarm signaling is required. devices on the circuit.The mapping feature provides supervision of each device's installed location to prevent a detector from being • SIGA-AB4G bases provide sounder capability to Signature reinstalled(after cleaning,etc.)in a different location from where it Series to heat and smoke detectors.They are not intended was originally. for use with combination carbon monoxide detectors in Fire-plus-CO mode. Fast Stable Communication On-board intelligence means • SIGA-AB4GT bases provide sounder capability to Signature less information needs to be sent between the detector and the Series smoke and heat detectors. as well as carbon loop controller. Other than regular supervisory polling response. monoxide detectors when used with a SIGA-TCDR Temporal the detector only needs to communicate with the loop controller Pattern Generator. when it has something new to report. • SIGA-AB4G-LF bases provide 520 Hz low frequency sounder capability to Signature Series smoke and heat detectors, as well as carbon monoxide detectors when used with a SIGA-TCDR Temporal Pattern Generator.The SIGA-AB4G-LF is suitable for applications requiring low frequency audible tones. Page 2 of 4 E85001-1 OO1 .. Issue 1.4 Typical Wiring The detector mounting bases accept#18 AWG(0.75mm2), #16 Audible Sounder Bases, Fire Mode (1.0mm%),#14 AWG(1.5mm2),and #12 AWG(2.5mm2)wire sizes. AB4GT.AB4G.AB4G-LF sounder bases Sizes 416 AWG(1.0mm')and 418 AWG(0.75mm2)are preferred for ease of installation, Standard Detector Base,SIGA-SB, SIGA-SB4 SIGA-AB4G" T, o SIGA-AB4G-LF; SIGA-AB4G, ® ® Output Mode This is the basic mounting SIGA-AB4G-LF: Jumper OilS Default=Fire base for EDWARDS Signature Remote LED Volume Setting Cu/remove jumper g Default=High for Fire plus CO Series detectors.The SIGA- Mox resistance Cut/remove per wire jumper for SIGA-AB4G: LED Remote LED is supported _ + must not exceed low dB ® ® Tone Setting by this Base. -- 10 Ohms Default=Temporal DATA-D Dal, a sio SIG. is ,uwUT Cut/remove jumper lam =cnpton I for Steady I hot Used r \), j III @ 1 III rN N()U I') 1. 1 1, 1. 1:•24.il (l DATA INI) 'ra l t 1'•`1 1"1' il 9 Resole ED I-) �. ResoleDATA OUT Id �'� ' I FD(.1 I. Not UsedDATA IN Int DATA OUT(s( 24 Vtic in DATA OLJ7 I1 From Signature Controller To Next Device From power supply + Emma -----•- 24 Vdc out or Previous Device or previous base II To next base or EOL relay -Data in Data nut Isolator Detector Base,SIGA-IB,SIGA-164 From Signature Controller 1 to next Signature device or previous device • e This base includes a built-in line fault isolator for use on Class A circuits.A detector must be installed for it to operate.The isolator base does not support the SIGA-LED Remote LED. Warnings & Cautions The isolator operates as follows: • This detector does not operate without electrical power. - a short on the line causes all vz As fires frequently cause power interruption, discuss isolators to open within 23 msec. /�0t o�:e _ 0 further safeguards with the local fire protection specialist. -at 10 msec intervals,beginning r °r ` ' - ;� • This detector does not sense fires in areas where smoke on one side of the Class A �► a A-- cannot reach the detector.Smoke from fires in walls, circuit nearest the loop DATA IN(- Gi zv` roofs, or on the opposite side of closed doors may controller, the isolators DATA OUT O PP not close to provide the - reach the detector. next isolator down DATA IN(+) DATA OUT TT-) • In Canada, install according to CAN/ULC-S524 Standard for the line with power. From Signature Controller To Next Device or Previous Device the Installation of Fire Alarm Systems,CSA C22.1 Canadian - when the isolator next rent) Dexe"p°p" Electrical Code,and the local authority having jurisdiction. 1 Nol Used to the short closes,it 2 DAM IN/out In) reopens within 10 msec. s DATA IN(-) 4 Not Used d Theprocess repeats beginning on 5 DA1Not Use p g� 9 Cr DATA OUT 0) � the other side of the loop controller. 7 Not Used Relay Detector Base, SIGA-RB,SIGA-RB4 This base includes a relay. Normans-No:warp Common Closed Opp en Normally Open or Normally Closed operation is selected during installation.The dry contact is rated for 1 amp ^ (pilot duty)@ 30 Vdc.The r relay's position is supervised to avoid accidentally jarring it DATA INO iviiii, :b DATA oaTr-, out of position.The SIGA-RB can be operated as a control DATA iNtot DATA r+, from signoture Controller To Next Device relay if programmed to do so or Previous Device T1N,D rx5],pliln I at the control panel.The relay __ I Nplmely OpenI_ base does not support the , ,iNtAl IT 0ATIN0 1 oAIA IN,TIUI(rI T 3 Awe tet 30 VD() 1 Common SIGA-LED Remote LED. L ,Past mw 4 y) DATA IN(-) Not Used Ii Nor:naliy itetu ed DATA 011(I Page 3 of 4 .. E85001 -1 001 Issue 1.4 • Dimensions R , C y✓ •-- r Contact us Phone: 800 655 4497(Option 4) k � iwlvd lOiu Os) (�� I Enail: F ri v rd rk r r� < �� I -r I Website <<Iyardsliresatet,.cornorm 4 8985Town Center Pkwy Bradenton,FL 34202 ©2021 Carrier All rights reserved. Specifications Operating voltage 15 20 to 19.95 VDC Normal operating current 32 pA Alarm current 45 pA Smoke Sensitivity Range UL/ULC:0.5 to 4.36%/ft.(1.6 to 13.6%/m)obscuration Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft./min(0 to 20 m/s) Wall mounting 12 in.(305 mm)max from ceiling Compatible bases See Ordering Information --------------- Compatible detector testers Testifire 1000.Testifire 2000 Operating environment 32 to 120°F(0 to 49°C),0 to 93%RH,noncondensing Construction High Impact Engineering Polymer,White Storage temperature -4 to 140°F(-20 to 60'C) Environmental compensation Automatic Agency Listings CAN/ULC-S529,UL 268-7,UL 268A,CSFM Ordering Information Catalogp Wt. NumberDescriptionbs(kg) SIGA OSD Intelligent Optical Smoke Detector 0.4(0,16) Accessories SIGA-SB Detector Mounting Base-Standard SIGA-SB4 4 inch Detector Mounting Base c/w Trim Skirt SIGA-RE Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Relay,c/w Trim Skirl 0.2(.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4 inch Detector Mounting Base w/Fault Isolator c/w Trim Skirt SIGA-LED Remote Alarm LED(not for EN54 applications) ase for Fire SIGA AB4G LE Low Frequency Audible(Sounder)Base for Detectors CO and/or Fire Detectors 00 ).3(0.15) SIGA AB4GT Audible(Sounder)Base for CO and/or Eire Detectors 0.3(0.15) SIGA TS4 Trim Skirt(supplied with 4-inch bases) 0,1 (0.04) SIGA-FS Trim Skirt (optional for non 4-inch bases) 0.1 (0.04) SIGA-DMP Detector Mounting Plate 3.0(1.4) SIGA-RTA Detector Removal Tool ---_ SIGA-VA Detector Cleaning Tool 0 Ca C p C t11 -1 1 Page 4 of 4 E8500 1 - 1 00 t Issue 1,4 t Intelligerr rF tiatil y Bev Intelligent Heat DetectorsAnwasoir SIGA-HRD, SIGA-HFD '`► "No N. . \N. S.953 Overview Standard Features The Signature Series smoke detectors bring advanced sensing Note:Some features described here may not be supported by technology to a practical design that increases efficiency, saves all control systems. Check your control panel's Installation and installation time,cuts costs, and extends property protection Operation Guide for details. capabilities.Continuous self-diagnostics ensures reliability over • Next Generation Heat Sensing Technology the long-haul,while the latest thermister technology makes these detectors ideal wherever dependable heat detection is required. • 135°F(57°C)fixed temperature alarm point(HRD and HFD) The SIGA-HRD is an intelligent fixed temperature/rate-of-rise fire • 15°F(9°C)per minute rate-of-rise alarm point(HRD) detector. tt monitors the temperature of the surrounding air and • Uses existing wiring analyzes the data from the sensor to determine whether to initiate an alarm.The rate-of-rise heat function quickly detects a fast, • Automatic device mapping flaming fire.The fixed-temperature heat function detects fire when • Sensor Markings Provide Easy Testing Identification the air temperature near the detector exceeds the alarm point. • Up To 250 Total Signature Devices Per Loop The SIGA-HFD is an intelligent fixed-temperature heat detec- tor that contains a fixed-temperature heat sensor rated at 135°F • Non-volatile memory (57.2°C). It does not have a rate-of-rise function.The heat sensor • Electronic addressing monitors the temperature of the air in its surroundings and the detector analyzes the data to determine when the air temperature • Bicolor(green/red)status LED near the detector exceeds the device's alarm point. • Standard, relay,fault isolator,and audible mounting bases • 50 foot(15.2 meter)spacing Page 1 of 4 - - E85001 -0647 Issue Z_2 Apclication Accessories The SIGA-HRD combination fixed temperature/rate-of-rise heat Detector mounting bases have wiring terminals that are acces detector provides a 15°F(9°C)per minute rate-of-rise heat sen- sible from the"room-side"after mounting the base to the electrical sor for the detection of fast-developing fires, as well as a 135°F box.The bases mount to North American 1-gang boxes and to (57°C)fixed temperature sensor for slow building-fires.The SIGA- 3 inch or 4 inch octagon boxes, 1 inches(38 aim)deep.They also mount to European BESA and 1-gang boxes with 60.3 min HFD fixed temperature detector provides a 135°F(57°C)fixed fixing centers.The SIGA-SB4,SIGA-RB4. and SIGA-IB4 mount to temperature sensor for slow building-tires. North American 4 inch sq.electrical boxes in addition to the above boxes.They include the SIGA-TS4 Trim Skirt, which is used to cover the"mounting ears'on the base.The SIGA-AB4G mounts Compatibility to a 4 inch square box only. , ,. Signature Series heat detectors are compatible only with the Sig- nature Loop Controller. /j _, • '" rp f 'y ' \ y , SIGA-AB4G/T/LF $IGA•SB SIGA-IB SIGA-RB SIGA-LED Installation Audible Base Standard Base Isolator Base Relay Base Remote LED Signature Series detectors mount Remote LED SIGA-LED-The remote LED connects to the to North American 1-gang boxes 5 SIGA-SB or SIGA-SB4 Standard Base only. It features a North 3-1/2 inch or 4 inch octagon =a American size 1-gang plastic faceplate with a white finish and red boxes, andto4 inch - self lockinglab c square elec ,. alarm LED. trical boxes 1-1/2 inches(38 mm) SIGA-TS4 Trim Skirt-Supplied with 4 inch bases, it can also deep. They mount to European ti be ordered separately to use with the other bases to help hide BESA and 1-gang boxes with 60.3 t , surface imperfections not covered by the smaller bases. mm fixing centers. See mounting y ,E Indra,e, base installation and wiring for w- Sounder Bases- Signature Series sounder bases are designed for use where localized or group alarm signaling is required. more information. • SIGA-AB4G bases provide sounder capability to Signature Series to heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire- Sensing and reporting technology plus-CO mode. The microprocessor in each detector provides additional benefits- • SIGA-AB4GT bases provide sounder capability to Signature Self-diagnostics and History Log,Automatic Device Mapping, and Series smoke and heat detectors, as well as carbon monox- Fast,Stable Communication. ide detectors when used with a SIGA-TCDR Temporal Pattern Generator. Self-diagnostics and History Log- Each Signature Series • SIGA-AB4G-LF bases provide 520 Hz low frequency detector constantly runs self-checks to provide important mainte- sounder capability to Signature Series smoke and heat detec- nance information. The results of the self-check are automatically tors,as well as carbon monoxide detectors when used with a updated and permanently stored in the detector's non-volatile SIGA-TCDR Temporal Pattern Generator.The SIGA-AB4G-LF memory. is suitable for applications requiring low frequency audible Automatic Device Mapping -The loop controller learns where tones. each device's serial number address is installed relative to other devices on the circuit.The mapping feature provides supervision of each device's installed location to prevent a detector from being Warnings & Cautions reinstalled(after cleaning etc.)in a different location from where it • This detector does not operate without electrical power.As was originally. fires frequently cause power interruption. discuss further safe- Fast Stable Communication -On-board intelligence means less guards with the local fire protection specialist. information needs to be sent between the detector and the loop • This detector does not sense fires in areas where heat cannot controller. Other than regular supervisory polling response, the reach the detector. Heat from fires in walls, roofs,or on the detector only needs to communicate with the loop controller when opposite side of closed doors may not reach the detector. it has something new to report. This heat detector byitself does notprovide life• ' safety protec- tion Use this detector with ionization and/or photoelectric smoke detectors. • This detector does not detect oxygen levels, smoke, toxic gases, or flames. Use this device as part of a broad-based life safety program which includes a variety of information sources pertaining to heat and smoke levels. extinguishment systems,visual and audible devices. and other safety mea- sures. • Independent studies indicate that heat detectors should only be used when property protection alone is involved. Never rely on heat detectors as the sole means of fire protection. Page 2 of 4 E85001-0647 Issue 2.2 Typical Wiring The detector mounting bases accept#18 AWG(0.75mm2). #16 Relay Detector Base,SIGA-RB, SIGA-RB4 Normally-Narmolly- (1.0mm2), #14 AWG(1.5mm2),and #12 AWG(2.5mm2)wire sizes. This base includes a relay. Nor- `ammo Cloyed open Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred mally Open or Normally Closed for ease of installation. operation is selected during in- stallation. The dry contact is rated ,s 6., \ Standard Detector Base,SIGA-SB,SIGA-SB4 for 1 amp(pilot duty)©30 Vdc. fin. The relay's position is supervised This is the basic mounting base Remote LED to avoid accidentally jarring it out \" ' 4' . for EDWARDS Signature Series - Max resistance of position.The SIGA-RB can be DAIAINe-) \ r.' i DATA OUT I-) detectors.The SIGA-LED Re- per wire operated as a control relay if pro- + must not exceed DATA OUT(H mote LED is supported by this _ iD ohms grammed to do so at the control DATA NV(+> o NeM Device From Signature Controller Base. panel.The relay base does not or Previous Device term Description support the SIGA-LED Remote Term Description 1 Not Used 1 Norm*Open 2 DATA IN/OUT iv) l LED. CONTACT HAI ING 2 DATA IN/OUT I+) 3 Not Used I I'thy 1.0 Amp @ 30 VDC 3 Common 4 DATA IN i(-) 7 (Pot Duty) 4 DATA IN(-) 4 Remote I Et)(-) DATA IN I- '_ v DATA DUI I-! 5 Not Wed 5 Demote LED(+) -- 6 Normally-Closed 6 Not Used ) — I 7 DATA OUT(-) 7 DATA OUT(-) DATA IN(+) DATA OUT TO From Signature Controller To Next Device or Previous Device Audible Sounder Bases, Fire Mode Isolator Detector Base,SIGA-IB, SIGA-IB4 AB4GT,AB4G,AB4G-LF sounder bases This base includesttoa bmust rose fault orisolatorittofor use.on Class A circuits.A detector must be installed for it to operate. The isolator --Thi r base does not support the SIGA-LED Remote LED. SIGA-AB4Gr, o O SIGA-AB4G-LF. SIGA-AB4G. ® ® Output Mode The isolator operates as follows: SIGA-AB4G-LF: Jumper cuts Default=Fire - a short on the line causes all iso- -° ? 0 Volume Setting Default=High Cut/remove jumper for G OFire plus CO lators to open within 23 msec - a a7 Cut/remove - at 10 msec intervals, oo jumper for SIGA-AB4G: beginning on one side •\ ®�.y_ ow dB ® al Tone Settingof the Class A DATA IN DATA-AUTO-DATA, Default=Temporal O l ' ° DATA OUT(-) SIG. SIG. OUT n ISTOUT Cutremove jumper for circuit nearest the loop ___� I I 'I I I I I A Steady > i�.I�.I..i..1 controller,the isolators DATA OUT(+) t,.ILL,4t. t SIGA-AB4GT: close to provide the DATA IN(+) to NextDevice IC+gI ig#Ig�I r+gI IWI Not Used next isolator down the From Signature Controller I t ICI I t or Previous Device 1'11111I line with power WOO De cripron 1 Not Used 24 Vdc in - when the isolator next - MIMEO - 24 vec out 2 DATA IN/OUT(-) From power supply to the short closes,it reopens within 10 3 DATA IN(-I or previous base + .,' + To next base or EOL relay 4 Not Used msec. N°l Used - F. DA;A OUT') Data in Data out The process repeats beginning on the 7 Nol Used From Signature Controller - to next Signature device other side of the loop controller. or previous device + Li Page 3 of 4 . . E85001-0647 Issue 2.2 " Dimensions ,. . /* _- / <� � Contact us I ll� �� Phone: 800 655 4497(Option 4) �tt (- i pp dIN@a1ou00 I� � �� 11' Email ec �i re. nrl;ra \ ?- 0 1' ,fINl ..i �� '��‘ --1:‘,,,„',j. ,i Website ..ard;7esn __ ( i- 8985 Town Center Pkwy y,)'' ---- ' ---- - Bradenton,FL 34202 O 2020 Carrier All rights reserved. Specifications SIGA-HRD 1 SIGA-HFD Operating voltage 15.20 to 19.95 VDC ..-................ Normal operating current 32 pA Alarni current 32 pA --- _- - Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Rate-of-rise rating - --- -_ __.._...__..__.._ 5°F/min(8°C/min) i NA Fixed temperature rating 135°F(57.2°C).Actual alarm point 129 to 141°F(53.9 to 60.6°C). Maximum spacing 50 ft.(15.2 m)centers Compatible bases See Ordering Information Compatible detector testers Testifire 1000,Testifire 2000 Operating environment Construction Storage temperature Testifire 2000 32 to 100°F(0 to 35°C),0 to 93%RH,noncondensing ----- ---- _ - High Impact Engineering Polymer,White -4 to 140°F(-20 to 60°C) Agency Listings CAN/ULC-S530,UL 521 , CAN/ULC-S530-M91, UL 521 Ordering Information Catalog Description Ship Wt. Number lbs k ( 9) SIGA HRD Intelligent fixed terperature/Rate of rise heat detector - - __- SIGA HFD Intelligent fixed temperature heat detector 0.4(0.16) Compatible Bases SIGA-SB, Detector Mounting Base -Standard - -_- _-e SIGA-SB4 4 inch Detector Mounting Base c/w Trim Skirt -- SIGA-RB Detector Mounting Base w/Relay SIC.3A RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt 0,2(.09) SIGA-IB Detector Mounting Base w/Fault Isolator -__-- SIGA 184 4-inch Detector Mounting Base w/Fault Isolator,c/w Trim Skirt SICA-AR4G Audible(Sounder)Base for Fire Detectors - - SIGA A 4G-LF I ow Frequency Audible(Sounder)Base for CO and Fire Detectors 0-3 10.15) SIGA A[34Gi Audible(Sounder)Base for CO and Fire Detectors SIGA-LED Remote Alarm LED(riot for EN54 applications) -- SIGA S4 Trim Skirt(supplied with 4 inch bases) --- _._.. .__ -- _ 0 1 {0.04) SIGA-TS Trim Skirt(optional for non 4-inch bases) - SIGA-RTA Detector Removal Tool 0 P Page 4 of 4 E85001-0647 o I Issue 2.2 ,..v °''''�`t",."`°`"""'-. I.ntelligent I iilat:ng -4:1 i ti,lf) 1 H 13 Manual Full I I. Stations Lll., 1,,,„,„; FIRE Sul- tiAraO; r SIGA-270, SIGA-270P, . . SIGA-278 ,„ k. , DWARp$ 33,,,'" .., ,, SIGA-270 SERIES 1' -•r. '',,, Patented U1 SIGA 278 MEA ® 7150-1657: 0129 S2318 Overview • Break glass operation An up-front visible glass rod on the SIGA-270 discourages The SIGA-270 and SIGA-278 series Manual Pull Stations are part tampering. of EDWARDS's Signature Series system.The SIGA-270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape.They • Intelligent device with integral microprocessor are made from die-cast zinc and finished with red epoxy powder- All decisions are made at the station allowing lower corn- coat paint complemented by aluminum colored stripes and mark- munication speed while substantially improving control panel ings. With positive pull-lever operation,one pull on the station response time. Less sensitive to line noise and loop wiring handle breaks the glass rod and turns in a positive alarm,ensuring properties;twisted or shielded wire is not required. protection plus fool-proof operation.Presignal models(SIGA-270P) . ADA Compliant are equipped with a general alarm(GA)keyswitch for applications Meets ADA re quirements for manual pull stations. where two stage operation is required.The up-front highly visible glass rod discourages tampering, but is not required for proper • Electronic Addressing with Non-volatile memory operation. Permanently stores programmable address,serial number, type of device,and job number.Automatically updates historic EDWARDS's double action single stage SIGA-278 station is a information including hours of operation,last maintenance contemporary style manual station made from durable red colored date, number of alarms and troubles,and time and date of last lexan. To initiate an alarm,first lift the upper door marked"LIFT alarm. THEN PULL HANDLE", then pull the alarm handle. • Automatic device mapping Each station transmits wiring information to the loop control- Standard Features ler regarding its location with respect to other devices on the Note:Same features described here may not be supported by all control sys- circuit. tems.Check your control panel's Installation and Operation Guide for details. • Diagnostic LEDs • Traditional familiar appearance Status LEDs;flashing GREEN shows normal polling; flashing SIGA-270 models feature our familiar teardrop design with RED shows alarm state. simple positive pull action and sturdy die-cast metal body. • Designed for high ambient temperature operation • One stage GA,two stage Install in ambient temperatures up to 120"F(49°C). g ( ) g (pre-signal),and double action models SIGA-270 models are available for one or two stage alarm systems.The single stage double action SIGA-278 features a rugged Lexan housing with keyed reset mechanism. Page 1 of 4 E85001-0279 Issue 1.1 Application Typical Wiring The operating characteristics of the fire alarm stations are deter- The fire alarm station's terminal block accepts#18 AWG(0.75mmt) mined by their sub-type code or"Personality Code". NORMALLY- to 412 AWG(2.5mm')wire sizes, See Signature Loop Controller OPEN ALARM-LATCHING(Pesonality Code 1) is assigned by the catalog sheet for detailed wiring requirement-specifications. factory; no user configuration is required. The device is configured for Class B IDC operation.An ALARM signal is sent to the loop Wiring Notes controller when the station's pull lever is operated.The alarm con n Refer to Signature Loop Controller manual for maximum dition is latched at the station. wire distance. 2. All wiring is power limited and supervised. Compatibility REAR VIEW of 278 Signature Series manual stations are compatible only with ED- WARDS's Signature Loop Controller. 0 lest Warnings & Cautions This device will not operate without electrical power.As fires fre- quently cause power interruption,we suggest you discuss further Rea LED Green LED (Alarm/Active) (Normal) safeguards with your local fire protection specialist. orBT ; Testing & Maintenance 61■IU1111 To test(or reset)the station simply open the station and operate l DATA IN CO , DATA OUT(n)ll the exposed switch.The SIGA-270 series are opened with a tool; , DATA IN(-) DATA OUT(-)f the SIGA-278 requires the key which is supplied with that station. From Signature Controller q To NextDevae or Previous Device L The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message.The user-friendly maintenance Figure 4. Single Stage Systems program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily, from the control panel.Availability of maintenance features is dependent on the fire alarm system used. REAR VIEW of Scheduled maintenance(Regular or Selected)for proper system 270P.27oPa ® o0 operation should be planned to meet the requirements of the Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and o 0 ULC CAN/ULC 536 standards. BZ A / 6 5 Red LED Green LED (Alarrn/Active) —• c 't (Normal) 0 h f DATA IN , DATA OUT).)} DATA IN(-) - DATA OUT(-)1} From Signature Controller To Next Device or Previous Device A\ Figure 5. Two Stage Systems Page 2 of 4 E85001-0279 issue 1.1 Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 21/2 inch(64 mm)deep 1-gang boxes. Two stage presignal(270P)models require 11/2 inch (38 mm)deep 4-inch square boxes with 1-gang, 1/-inch raised covers. Openings must be angular.Rounded opernngs are not acceptable. Recommended box:Steel City Model 52-C-13; in Canada, use Iberville Model CI- 52-C-49-1/2. All models include terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. EDWARDS recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station,saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory.The loop controller identifies each device on the loop and assigns a"soft"address to each serial number. If desired, the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Latch Compatible Electrical Box Compatible Electrical Box Cover Release tt Cover • s.l I I -- ai ;.et4 Release J,..,' I v. t Screw p0,ytIat I \ çoo • 20 00 0 5 Toggle i 0 Toggle it -4If 1s %� V o R Glass Rod 0 '. ' Glass Rod \ - Release Lever OPEN 141\s...,.. Figure 1. SIGA-278 installation Figure 2. SIGA-270,SIGC-270F,SIGC-270B installation Cave,Release 5cr 0 O A—Compoilble O Syr+2 Ele't aI Box to sed covers--1. —' \ ©na ) gt 1 CP Back‘ plate 1� Toggle witch o 3Ea �®fi bo % � Glass Pod - Release to°er not use bones with rounded openings. ' Figure 3. SIGA-270P,SIGC-270PB installation Page 3 of 4 E85001-0279 Issue 1.1 Specifications SIGA-270 SIGC SIGA-270P, Catalog Number _ : 270E SIGC 2706 I SIGC-270PB SIGA 278 Description Single Action Single Action-Two I Double Action -One Stage Stage(Presignal) -One Stage _ .-..._..__._..-- Contact us Addressing Uses 1 Module Uses 2 Module I Uses 1 Module Phone: 800-655-4497(Option 4) Requirements Address Addresses Address Email: ec and eAcs ccm Operating Current Standby=2500A Standby-396pA - Standby=2b0pA Website: r< ar,lsfiro ar t, m Activated=400pA Activated-680pA - Activated=400pA 8985 Town Center Pkwy Diecast Zinc-Red Epoxy Lexan Red with Bradenton,FL 34202 Construction&Finish with aluminum markings I white markings Type Code Factory Set ©2020 Carrier -- «.- _..... ..._ All rights reserved. Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Storage and Operating Operating Temperature: 32 F to 120°F(0°C to 49°C) Environment Storage Temperature: -4°F to 140`F(-20°C to 60°C)Humidity:0 to 93% RH LED Operation On-board Green LED-Flashes when polled On-board Red LED-Flashes w hen in alarm Compatibility Use With:Signature Loop Controller Agency Listings UL,ULC(note 1), MEA,CSFM,FM Note:SIGC-270F,SIGC-270B and SIGC-270P8 are ULC listed only.Suffix"F"indicates French markings. Suffix"B"indicates English/French biting ual markings. Ordering Information Catalog Ship Wt. Number Description lbs(kg) , SIGA-270 One Stage Fire Alarm Station, English Markings UL/ULC Listed SIGC-270F One Stage Fire Alarm Station, French Markings- ULC Listed SIGC-270B One Stage Fire Alarm Station, French/English Markings-ULC Listed SIGA-270P Two Stage(Presignal)Fire Alarm Station, English Markings-11UULC Listed 1 (0.5) SIGC- Two Stage(Presignal)Fire Alarm Station, French/English Markings 270PB -ULC Listed SIGA-278 Double Action(One Stage)Fire Alarm Station, English Markings ..-._..__............ UL/ULC Listed Accessories • 32997 GA Key w/Tag for pre signal station(CANADA ONLY) 276-K2 GA Key-for pre-signal station (USA ONLY) 276 K1 Station Reset Key Supplied with all Key Reset Stations 27165 12 Glass Hods-for SIGA-270 series(CANADA ONI Y) 0.1 (.05) 270-GLR 20 Glass Rods-for SIGA-270 series (USA ONLY) 276-GLR 20 Glass Pods for SIGA-278 series - 276B-RSR Surface Mount Box, Red-for SIGA pull stations 1 (0.6) 0 Page 4 of 4 E85001_0279 issue 1.1 Intelhaentnpu,tOutput � H r = *pay sry,� • Nigh Power . . . ; ontrol Relay • • Module nom SIGA-CRH Description Standard Features The SIGA-CRH High Power Control Relay Module is an address- • High Power Rating able device designed for interface applications that require a high 120/240 VAC or 24 VDC rated contact can be used to control voltage, high current relay.Two identical sets of relay terminals are external appliances such as door closers,fans,dampers etc. provided. Both sets of relay contacts transfer when the module • Provides one relay with two Form C contacts is activated or restored.The state of the output terminals is not Relay accepts 12 to 18 AWG(1.0 to 4.0 mm2)wiring from two supervised. sources The module requires one address on the signaling line circuit • Automatic device mapping (SLC).The address is assigned electronically.There are no ad- Signature modules transmit information to the loop controller dress switches to set. regarding their circuit locations with respect to other Signature devices on the wire loop. • Removable terminal blocks Easy wiring and module replacement. • Electronic addressing Programmable addresses are downloaded from the loop con- troller or PC;there are no switches or dials to set. • Intelligent device Distributed intelligence allows lower communication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties;twisted or shielded wire is not required. Paget of 4 E85OO1-0644 sue 1.1 Apalication Installation Personality code Compatible electrical box Use Personality Code 8 to configure the SIGA-CRH module: Personality code 8:Signal- dry contact output. Configures % '�-� SIGA-CRI I the module as a dry relay contact to control external appli- � �_ ances(door closers,fan controllers, dampers)or equipment d ° ( Wall plate shutdown. 0 %VI' �� Indication �> r oI --„, ,'czy The status LED shows the state of the module through the cover P 0 plate: '-„�\ 0 ° • Normal: Green LED flashes , ° - °g° • Alarm/active: Red LED flashes ,� (/ Compatibility The SIGA-CRH is part of the Signature Series intelligent process- ing and control platform. It is compatible with EST3, EST3X,and Consult the SIGA-CRH High Power Control Relay Module Installa- iO Series control panels. tion Sheet for details. Warnings&Cautions The SIGA-CRH will not operate without electrical power.As fires Wiring frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. O o 0 � (1) Co EDWARDS recommends that this module be installed according -+ to latest recognized edition of national and local fire alarm codes. o ' -- i edmi _ Nil N ^I (4) 411110 (3) cz (5) -(7) Testing&Maintenance 11"1#1�l ' Noz MI) (6) SIGA-CRH automatic self-diagnosis identifies when it is defective �'I if Nc1 a (4) and causes a trouble message.The user-friendly maintenance M- c1 gal, (5) —(8) program shows the current state of each module and other per- ,,- No; MITI' (6) tinent messages. Single modules may be turned off(deactivated) II_, vJ — temporarily,from the control panel.Availability of maintenance o l=-_ I _t features is dependent on the fire alarm system used.Scheduled (2) maintenance(Regular or Selected)for proper system operation 0 a 0 should be planned to meet the requirements of the Authority Hav- ing Jurisdiction(AHJ). Refer to current NFPA 72 and ULC CAN/ (1) Signaling line circuit(SLC)Irom previous device ULC 536 standards. (2) Signaling line circuit(SLC)to next device (3) Power-limited and supervised Electronic Addressing (4) Normally closed contact(NC) The loop controller electronically addresses the SIGA-CRH, saving (5) Common contact(C) valuable time during system commissioning. Setting complicated (6) Normally open contact(NO) switches or dials is not required.l he module has its own unique (7) Relay terminal set 2. serial number stored in its on-board memory. Not supervised.Power-limited unless connected to a nonpowerinnited source. If the source is nonpower-limited,eliminate the power-limited mark and maintain a minimum of 0.25 in. (6.4 mm)space from power-limited wiring.For other mounting methods,see enclosure and bracket installation sheets to maintain separation of power-limited and nonpower-limited wiring.The wire size must be capable of handling fault current from a nonpower-limited source. — or— Use type FPL, [PLR, FPLP,or permitted substitute cables,provided these power-limited cable conductors extending beyond the jacket are separated by a minimum of 0.25 in.(6.4 rnr))space or by a nonconductive sleeve or nonconductive barrier from all other conductors.Refer to the NFPA 70 National Electrical Code for more details. (8) Relay terminal set 1. Identical to(7). Page 2 of 4 E85001-0644 issue 1.1 Specifications Orcering Information SLC operating voltage 15.20 to 19.95 VDC Catalog Ship Weight .._... Description Si.C current Number Ibs(kg) Standby 75 pA max. v SIGA-CRH I ligh Power Control Relay Module 0.4(0.15) Activated 75 pA max. _..... _. .... .__._... Contact ratings[1][2] 240 V 50/60 Hz 7 A(PF 0.75), 1.5 A(PF 0.35) 120 V 50/60 Hz 7 A(PF 0.75),3.0 A(PF 0.35) 24 VDC 6 A resistive Audio switching 0 to 20 kHz 13] Relay type 2 Form C,programmable Relay ready delay 30 s max.(includes initial state set) From power up • From previous activation 5 s max.(one activation) 8 s max.(two activations,1 s apart) Circuit designation Signaling line circuits Class A,Style 6 or Class 8,Style 4. Refer to the control panel technical publications for SLC wiring details. Relay circuits Class E Number of SIGA-CRH per SLC 60 max. Wire size 12 to 18 AWG(1.0 to 4.0 mm2) North American double-gang x 2-1/8 Compatible electrical boxes in.(54 min)deep box North American standard 4 in.square x 2-1/8 in.(54 mm)deep box Agency Listings CAN/ULC-S527, UL 864 Operating environment Temperature 32 to 120°F(0 to 49°C) Relative humidity 0 to 93%,noncondensing Storage temperature -4 to 140°F(-20 to 60°C) 111 Provide external fusing and back-EMF mitigation as required by your application.Do not use the SIGA-CRH in a mixed application, where one set of relay terminals has high-power requirements and the other set carries a low-power signal,as this may result in physical contamination of the low-power signal contacts. [2] The minimum load required in order to avoid long-term contact oxidation is 100 mA and 12 V. [3] Power must not exceed the contact ratings shown for a given PF (power factor). Page 3 of 4 E85001-0644 issue 1.1 Universal I npu `- ,,y SIGA-U10612 Output Mcut FAA � � � f P yy�gi Motherboardskt .bra. / �� �: i �� SIGA-UI02R, SIGA-UI06R .` �M... 7300ae5r_ • 5 = ' v 0121 ti UL SIGA-U102R S3424 Overview Standard Features Signature Series Universal Input-Output Module Motherboards • Modular flexibility provide mounting and wiring terminations for up to six Signature Wide assortment of multi-function plug-in modules provides Series plug-in UIO(SIGA-"M"series)modules. UIO motherboards total flexibility. slide into a rigid extruded track(included)with mounting pads • for convenient mounting into a variety of equipment enclosures. Minimum wiring requirements U10 modules plug into the board and are held securely in place Integral jumpers between modules allow sharing of risers to with captive machine screws.All field wiring connects to terminal educe installation wiring. blocks on the motherboard,which permits rapid removal and • Easy installation replacement of modules for troubleshooting. #12 AWG(2.5 mm2)terminal blocks and sturdy mounting pads The SIGA-UIO2R provides mounting and wiring terminations for ensure quick installation into EDWARDS enclosures. up to two UIO modules, and the SIGA-UIO6R provides mounting • Supports automatic device mapping and wiring terminations for up to six U1O modules. Both mother- All compatible UIO modules transmit information to the loop boards feature a riser#1 input and a riser#2 input bus. Jumpers controller regarding their circuit locations with respect to other on riser#1 input, between modules,facilitate sharing a single riser Signature devices on the wire loop. among more than one module.This significantly reduces wiring requirements. Removing the jumpers provide separate riser inputs • Supports intelligent devices to each adjacent module. Riser 42 input is fixed to each module On-board modules make decisions and input an alarm from position and cannot be split. initiating devices connected to them even if the loop controller's The SIGA-UIO6 provides mounting and wiring terminations for up polling interrogation stops. to six U10 modules.This motherboard provides two riser inputs • Twisted or shielded wire not required that are common to all modules. Because all decisions are made at the on-board modules, lower communication speeds are possible.This results in substantially improved control panel response time and less sensitivity to line noise and loop wiring properties. • Supports electronic addressing Programmable addresses are downloaded to compatible UIO modules from the loop controller, a PC,or the SIGA-PRO Signature Program/Service Tool.There are no switches or dials to set. Page' of 4 E85001-0365 Issue 1.1 Mounting and Installation Mount the UIO motherboard inside a EDWARDS MFC-A cabinet or other suitable electrical enclosure with screws and washers provided. Each MFC-A will hold one U102R motherboard or one U106 or U106R motherboard complete with their full complement o of modules. fc �� . Plug a Signature Series U10 module into any available position on the motherboard and secure the module to the motherboard with the captive screws.Wiring connections are made to the terminals the MFC-A cabinet rs UL listed for use with UI0 moth rssr on the motherboard(see wiring diagram). UIO motherboard erboards and meets requirements[or spacing and clearance around the components. terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2) wire size. EDWARDS recommends that all boards and modules be installed according to latest recognized edition of national and local fire alarm codes. UiO Motherboard Testing & Maintenance i Plug-in(U10) The module's automatic self-diagnosis identifies when it is Module defective and causes a trouble message. The user-friendly n _wit maintenance program shows the current state of each module u and other pertinent messages. Single modules may be turned off e --- (de-activated)temporarily, from the control panel. Scheduled maintenance(Regular or Selected)for proper system operation should be planned to meet the requirements of the _ Cabinet or electrical enclosure Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Compatibility Signature Series Universal Input/Output Module Boards are compatible only with SIGA-"M"Series I/O Modules,which require a Signature Data Controller.They are compatible with EST3, EST3X and i0 Series control panels. Warnings & Cautions Signature devices will not operate without electrical power.As fires frequently cause power interruption. we suggest you discuss further safeguards with your fire protection specialist. Page 2 of 4 E85001 -0365 Issue 1.1 Typical Wiring Signature Series Universal Input/Output Motherboards have terminal blocks to accept#18 AWG(0.75mm2), #16 AWG(1.0mm7), #14 AWG(1.5mm7),and#12 AWG(2.5mm2)wire sizes. See Signature Data Controller catalog sheets for detailed wiling requirements and specifications. SIGA//-U102R SIGA-U106R odunsllahe(Refer to individu Module Input/Output t or wiring detalis - Moduieinput/Outputwiring mazy I ,e Taz DIM tiff Data In + B, Bata n + 9. Dollre a rein T91 Data Circuit common emes pd, sgnurure t 1- 1 Dow --- T815 nu„or M ser es z Input/Output+ Cur°I pu put Bust Dole out — modules � �t t 7 r l i , s r Cn ntooll + I i t t r _f� Mserres Jot°om modules lmaamum TB6 dIE�i•TM current _ JumpSr connect mmnon sBAmpsl inputs/outputs between n yf MOEulelnput,Csiput Wiring , duds rompers connect , ,e ,z, rzra A A common inputs __ — .. outputs between L- I Notes modules. Module Input/Output Wiring Imovimum Current is B Amps) Refer to individual elodu4 instellotion sheet for wiring details. A Jumpers may be used to make the inputs/outputs between modules common. 2) Not all modules use the SIGA-UIO2R terminals for the same SIGH-UI06 functions. Module u Input/Output Wiring Refer Co individual module installation sheet for wiring details. Q Refer to individual SIGA-M series installation sheets for jumper F— - - I settings and wiring information.Installations with multiple - -irisiri7 woe SIGA-UIO motherboards or enclosures(which include other y4 yyyy wiring)require FPL.FPLR,FF LP,or equivalent NEC-approved m n 4- Da m __ m'" rain Inpavo°,par eas t Common w all wire for all power limited wiring.Observe the details of M te;e. mode,e.lma,mam supervision and power limited versus non-power limited sq..re L, . ca,mn,e BAmps circuits.Refer to the SIGA-M series installation sheets. :roan r; � iB1S, Input/output Bus iI Tap I 1 I t Comment°on 4) Do not mix incompatible signals. Sato Oui ' modvbslma.imum "men)is Bnmpsl Q Maximum current is 8 Amps. 7) Refer to Signature Data Controller Installation Sheets for wiring specifications. Page 3 of 4 E85001 -0365 Issue 1.1 Specifications cWARDS Catalog Number SIGA-UIO2R SIGA-UIO6R SIGA-Ul06 '" Module Capacity ! Two Six Six 5.4 inch L(across Dimensions(with 9.56 inch L(across mounting feet)x 4 3 inch W mmodule installed) n�hnW g 3.2t 2tinch H x 3.2 inch H Contact us Phone: 800-655-449/(Option 4) Address Requirements no address required Email: ec a. silrc Type Code none Website: Compatible Modules _ All SIGA-Mxxx Signature Series 8985 Town Center Pkwy Operating Voltage ( 15.2 to 19.95 Vdc(19 Vdc nominal) Bradenton,FL 34202 Mounting(cabinets) 1 ,; Directly into suitable enclosures(e.g.:MFC-A) Notes 1 2 3. Wiring Terminals #12 AWG(2 5mm5)to#18 AWG(0 75mm5) ©2020 Carrier .....-- �...._�, _.._.. __ All rights reserved Operating Temperature.32°F to 120°F(0°C to 49°C) 9 Storage and Operating Storage Temperature.-4°F to 140°F(-20°C to 60°C) Environment ! Operating and Storage Humidity:0 to 93%RH Agency Listing _ UL,ULC,MEA CSFM Notes: 1. Allow a minimum clearance of one inch around all sides of the UIO motherboard. 2. On-site drilling of mounting holes may be required.Self-tapping mounting screws are provided. 3. Suitable cabinets:MFC-A,CAB2,3-CAB5,3-CAB7,3-CAB14,3-CAB21, 3-RCC series,RACC series. Ordering Information Catalog Description Ship Wt.-lb Number (kg) SIGA-U102R Universal Input-Output Module Board w/Riser Inputs 0.32(0.15) -Two Module Positions SIGA-U106R Universal Input-Output Module Board w/Riser Inputs -Six Module Positions 0.62 0.28) SIGA-U106 Universal Input-Output Module Board 0.56(0.25) Six Module Positions UL listed cabinet for mounting UIO motherboards,red with MFC-A white"FIRE"8 inch H X 14 inch W X 3.5 inch D(203 mrnH 7.0(3.1) X 356 mm W X 89 rnm D) 0 Page 4 of 4 E85001 -0365 0 Issue 1.1 c igent I^p,t, :.):put �� Input Modules , » � „:, t::,, SIGA-CT1 , SIGH-CT1 HT, SIGA-CT2, SIGA-MCT2 . .� t i� i 1;Y ; (a:,irij 4$,$ t il i if . i - ., ' " ""i" SIGA-CT1/2 SIGA-MCT2 �L I► MEA !_C 73001657 p121 $3424 Overview Standard Features The SIGA-CT1 Single Input Module,SIGA-CT1 HT High • Multiple applications Temperature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Including Alarm,Alarm with delayed latching (retard)for Input Modules are intelligent analog addressable devices used to waterflow applications,Supervisory,and Monitor.The installer connect one or two Class B normally-open Alarm,Supervisory,or selects one of four"personality codes"to be downloaded to Monitor type dry contact Initiating Device Circuits(IDC). the module through the loop controller. The actual function of these modules is determined by the • SIGA-CT1 HT rated for high temperature environments "personality code"selected by the installer This code is downloaded Suitable for attic installation and monitoring high temperature to the module from the Signature loop controller during system heat detectors. configuration. • Plug-in(U10)or standard 1-gang mount UIO versions allow quick installation where multiple modules The input modules gather analog information from the initiating are required.The 1-gang mount version is ideal for remote devices connected to them and convert it into digital signals. locations that require a single module. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. • Automatic device mapping Signature modules transmit information to the loop controller The SIGA-CT1, SIGA-CT1HT and SIGA-CT2 mount to standard regarding their circuit locations with respect to other Signature North American 1-gang electrical boxes, making them ideal for devices on the wire loop. locations where only one module is required. Separate VO and • Electronic addressing data loop connections are made to each module. Programmable addresses are downloaded from the loop The SIGA-CT1I-IT module operates at an expanded temperature controller, a PC,or the SIGA-PRO Signature Program/Service range of 32°F to 158°F(0°C to 70°C)for those applications Tool.There are no switches or dials to set. requiring more extreme environmental temperature variation. • Ground fault detection by address The SIGA-MCT2 is part of the UIO family of plug-in Signature Detects ground faults right down to the device level. Series modules. It functions identically to the SIGA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules.Two-and six-module UIO motherboards are available.All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Page 1 of 4 E8500 i-0241 Issue 1.1 Signature Series Overview _ The Signature Series intelligent analog-addressable system •--wo Motherboard from EDWARDS Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and o =•=0_ output modules, network and non-network control panels, and --C, d- -4 user-friendly maintenance and service tools.Analog information Pwg-in(uio) from equipment connected to Signature devices is gathered Module and converted into digital signals.An onboard microprocessor -a--`°°t in each Signature device measures and analyzes the signal and t 1 decides whether or not to input an alarm. The microprocessor in each Signature device provides four additional benefits-Self- —Cabinet or aiearical enclosure diagnostics and History Log,Automatic Device Mapping,and Fast, Stable Communication. Self-diagnostics and History Log-Each Signature Series Electronic Addressing -The loop controller electronically device constantly runs self-checks to provide important addresses each module, saving valuable time during system maintenance information.The results of the self-check are commissioning. Setting complicated switches or dials is not automatically updated and permanently stored in its non-volatile required. Each module has its own unique serial number stored memory. This information is accessible for review any time at the in its on-board memory.The loop controller identifies each device control panel, PC,or using the SIGA-PRO Signature Program/ on the loop and assigns a"soft"address to each serial number. Service Tool. If desired, the modules can be addressed using the SIGA-PRO Automatic Device Mapping-The Signature Data Controller Signature Program/Service Tool. (SDC)learns where each device's serial number address is EDWARDS recommends that this module be installed according installed relative to other devices on the circuit.The SDC keeps a to latest recognized edition of national and local fire alarm codes. map of all Signature Series devices connected to it.The Signature Series Data Entry Program also uses the mapping feature.With interactive menus and graphic support,the wired circuits between Application each device can be examined. Layout or"as-built" drawing The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is information showing branch wiring(T-taps), device types and their determined by their sub-type code or"Personality Code".The address are stored on disk for printing hard copy. code is selected by the installer depending upon the desired application and is downloaded from the loop controller. Installation One personality code can be assigned to the SIGA-CT1.Two SIGA-CT1,SIGA-CT1HT and SIGA-CT2:modules mount to personality codes can be assigned to the SIGA-CT2/MCT2. North American 21 inch(64 mm)deep 1-gang boxes and 11 inch Codes 1, 2,3 and 4 can be mixed on SIGA-CT2/MCT2 modules (38 mm)deep 4 inch square boxes with 1-gang covers and SIGA- only. For example, personality code 1 can be assigned to the first MP mounting plates.The terminals are suited for#12 to#18 AWG address(circuit A)and code 4 can be assigned to the second (2.5 mm2 to 0.75 mm2)wire size. address(circuit B). mil NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) comparbie eiectncei box -Assign to one or both circuits. Configures either circuit A or B or l'illAP----111 ------- both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc.An ALARM signal is sent to the loop controller when the input contact is closed. The alarm 'I condition is latched at the module. Wall plate wane NORMALLY-OPEN ALARM - DELAYED LATCHING Ilk, 1 (1-gang) �9% (Personality Code 2)-Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiating devices such as Waterflow Alarm Switches.An ALARM signal is sent to the loop controller when the input contact is � 4, closed for approximately 16 seconds.The alarm condition is • latched at the module. Status LEDs • NORMALLY-OPEN ACTIVE- NON-LATCHING (Personality LED viewing ports . '• Code 3) -Assign to one or both circuits. Configures either circuit o •Jj A or B or both for Class B normally-open dry contact monitoring ji input such as from Fans, Dampers, Doors, etc.An ACTIVE signal is sent to the loop controller when the input contact is closed.The SIGA-MCT2:mount the UIO motherboard inside a suitable ED- active condition is not latched at the module. WARDS enclosure with screws and washers provided. Plug the NORMALLY-OPEN ACTIVE - LATCHING(Personality Code SIGA-MCT2 into any available position on the motherboard and 4)-Assign to one or both circuits. Configures either circuit A or secure the module to the motherboard with the captive screws. B or both for Class B normally open dry contact monitoring input Wiring connections are made to the terminals on the motherboard such as from Supervisory and Tamper Switches. An ACTIVE signal (see wiring diagram). UIO motherboard terminals are suited for#12 is sent to the loop controller when the input contact is closed.The to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. active condition is latched at the module. Page 2 of 4 _ E85001 -0241 issue 1.1 Typical Wiring Modules will accept #18 AWG(0.75mm2), #16(1.0mm2), and #14AWG(1.50mm2). and#12 AWG(2.50mm')wire sizes. Note: Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating(Slave)Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms(25 ohms per wire)per Circuit Maximum Allowable Wire Capacitance 0.11IF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG(0.75 mm') #16 AWG(100mm2) #14 AWG(1.50 mm� 4,000 ft(1,219 rnj #12 AWG(1.50 mrn2) Typical N.O.Initialing Device Typical N.O.Initiating Device ♦ Jr INPUT 1 INPUT 2 A I, Style B(Gloss 8) T32 X B2 8 7 i.j UL/ULC Listed Style B(Class B) e • • 4701 EOL Ul7ULC Listed 8 7 6 5 f UL/ULC Listed ai 47Kr1'EOL L1\ • • m 47KS1 EOL l Red LED Green LED (Alarm/Active) ••' ii2-4 (Normal) Red LED 4, G I Green LED ' 4 3 2 7 (AlarmlAcIRe) 4 3 2 1 (Normal) TB1 i iT: TBI I MIMI 1OUTf DATADATA INN (-)t) I DATA OUI(ell (( DATA IN(4) 'DATA (v)lr ` DATA OUT(-)1 l DATA IN(-) ►DATA OUT(-)1 To Next Device From Signature Controller To Next Device From Signature Controller or Previous Device Q or Previous Device A 3 SIGA-CT1. SIGA-CT1 HT SIGA-CT2 NOTES 1 1 1 1 OMEai�: s nm, ;.°aor nMaximum 25 Ohm resistance per wire. 2\Maximum#12 AWG(2.5 mm2)wire;Minimum#18 AWG(0.75 mm2). AAA. n� Refer to Signature controller installation sheet for wiring specifications. /4\Maximum 10 Vdc @ 350 pA /� „r r / \The SIGA-V106R and the SIGA-U102R do not come with 7B14. 6 All wiring is supervised and power-limited. o° ". . • j LL 7 These modules will not support 2-wire smoke detectors. � i ' Data r - 1 Iglu p' °,n' 8) xoeoe+ 1)i i V g - �... .,. Wnrnin s & Cautions I ') ' u�°rro om m°n L' ,}1 l' , This module will not operate without electrical power.As fires fre- w j r I quently cause power interruption.we suggest you discuss further safeguards with your local fire protection specialist. ",°,° ,— ""'°°""'"'"` Compatibility slGA-M`T These modules are part of EDWARDS's Signature Series intelligent processing and control platform.They are compatible with EST3, EST3X and i0 Series control panels. Page 3 of 4 E85001-0241 Issue 1.1 Specifications ANZEDWARDt,- Catalog Number SIGA-CT1HT SIGA-CT1 SIGH CT2 SIGA-MCT2 Description � Single Input Module Dual Input Module Type Code 48(factory set)Four sub-types 49(factory set)Four sub types (personality codes)are available (personality codes)are available Contact us Address Requirements Uses One Module Addicss Uses Two Module Addresses ---- — ----_ -_..._Phone: 800 655-4497(Option 4) Operating Current Standby=2500A; Standby=396pA; Email: c nnfs.ig aS lnr.cc,n1., Activated=400pA Activated=680pA Website r cis:1_;irr =0_ ._i. Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) 8985 Town Center Pkwy Construction High Impact Engineering Polymer Bradenton,FL 34202 —,,.. _..... Mounting North American 21/2 inch(64 mm)deep one-gang box- U102R/6R/6 ©2020 Carrier es and 1 Y inch (38 mm)deep 4 inch square boxes Motherboard Alt rights reserved. with one-gang covers and SIGA-MP mounting y 9 plates Operating Environment 32°F to 158`F 32 F to 120°F(0°C to 49°C) (0°C to 70°C) Storage Environment -4°F to 140°F(-20°C to 60"C) Humidly.0 to 93%RH RH LED Operation On-board Green LED Flashes when polled;On-board Red LED- Flashes when in alarm/active. Compatibility Use with Signature Loop Controller Agency Listings UL,ULC,MFA CSFM Ordering Information Catalog Description Ship Wt. Number lbs(kg) SIGA-CT1 Single Input Module UUULC Listed 0.4(0.15) SIGA CT1 HT Single Input Module High Temperature Operation UUULC Listed 0.4(0.15) SIGA-CT2 Dual Input Module— UUULC Listed 0.4(0.15) _ SIGA-MCT2 Dual Input Plug-in(1110)Module UL ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box-Red 1-gang 1.0(0.6) 27193-16 Surface Mount Box-White, 1 gang 1 0(0.6) SIGA-UIO2R Universal Module Positions Board w/Riser Inputs Input-Output 0.32(0.15) SIGA-U106R Universal Input-Output Module Board w✓/Riser Inputs 0.62(0.28) — Six Module Positions �.T. SIGA-U106 Universal Input Output Module Board Six Modulo Positions 0.56(0.25) MFC-A Multifunction Fire Cabinet — Rod.supports Signature Module 7.0(3.1) Mounting Plates ......_._.._..............._ SIGA-MB4 Transponder Mounting Bracket(allows for mounting two 1-gang modules in a 2-gang box) 0.4(0.15) SIGA-MP1 Signature Moduie Mounting Plate. 1 footprint 1.5(0.(0) SIGA MP2 Signature Module Mounting Plate. 1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mo unting ounting Piate 1/2 extended footprint 1.02(0 46) 0 Page 4 of 4 E85001-0241 Issue 1.1 - L ^Y---. Ir elfl c„r,t Ini t .mrg iiik, . u .� of ,s1 Illr , zi4l�.*v6�R ,,A('v l r Control Relay e e, Modules ,,; , ,, , jH SIGA CR SIGA MCR, SIGA iI CAR, SIGA—MCRR }` grI3 I _..... -i 4 G' I'''''4C Sq* R- I SIGA CR SIGA-MCR rm MEA 73000-57' S3® Overview Standard Features The Control Relay Module and the Polarity Reversal Relay Module • Provides one no/nc contact(SIGA-CR/MCR) are part of the Signature Series system.They are intelligent analog Form"C"dry relay contact can be used to control external addressable devices available in either plug-in(UIO)versions,or appliances such as door closers,fans,dampers etc. standard 1-gang mount versions. • Allows group operation of sounder bases The SIGA-CR/MCR Control Relay Module provides a Form The SIGA-CRR/MCRR reverses the polarity of its 24 Vdc "C"dry relay contact to control external appliances such as output,thus activating all Sounder Bases on the data loop. door closers,fans,dampers etc.This device does not provide • Plug-in (UIO)or standard 1-gang mount supervision of the state of the relay contact. Instead,the on-board UIO versions allow quick installation where multiple modules microprocessor ensures that the relay is in the proper ON/OFF are required.The 1-gang mount version is ideal for remote state. Upon command from the loop controller,the SIGA-CR/MCR locations that require a single module. relay activates the normally open or normally-closed contact. • Automatic device mapping The SIGA-CRR/MCRR Polarity Reversal Relay Module provides Signature modules transmit information to the loop controller a Form"C"dry relay contact to power and activate a series of regarding their circuit locations with respect to other Signature SIGA-AB4G Audible Sounder Bases. Upon command from the devices on the wire loop. Signature loop controller,the SIGA-CRR reverses the polarity of its • Electronic addressing 24 Vdc output,thus activating all Sounder Bases on the data loop. Programmable addresses are downloaded from the loop Standard-mount versions(SIGA-CR and SIGA-CRR)are controller, a PC,or the SIGA-PRO Signature Program/Service installed to standard North American 1-gang electrical boxes, Tool; there are no switches or dials to set. making them ideal for locations where only one module is • Intelligent device with microprocessor required. Separate I/O and data loop connections are made to All decisions are made at the module to allow lower each module. communication speed with substantially improved control panel Plug-in UIO versions (SIGA-MCR and SIGA-MCRR)are response time and less sensitivity to line noise and loop wiring pad of the UIO family of plug-in Signature Series modules properties;twisted or shielded wire is not required. They function identically to the standard mount versions, but take advantage of the modular flexibility and easy installation that characterizes all UIO modules.Two- and six-module UIO motherboards are available.All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. Page 1 of 6 E85001-0239 Issue 1.1 • Installation Application SIGA-CR and SIGA-CRR:modules mount to North American The operation of Signature Series control relays is determined by 2/ inch(64 mm)deep 1-gang boxes and 11/2 inch(38 mm)deep their sub-type code or"Personality Code." 4 inch square boxes with 1-gang covers and SIGA-MP mounting plates.The terminals are suited for#12 to#18 AWG(2.5 mm2 to Personality Code 8:CONTROL RELAY(SIGA-CRIMGR) 0.75 mm2)wire size. Dry Contact Output. This setting configures the module to provide one Form "C" DRY RELAY CONTACT to control Door OP Closers, Fans, Dampers,etc. Contact rating is 2.0 amp @ 11111014111 Compatible electrical box 24 Vdc;0.5 amp @ 120 Vac(or 0.25A @ 220 Vac for non-UL applications). Personality Code 8 is assigned at the factory. No �l I user configuration is required. 0Personality Code 8: POLARITY REVERSAL RELAY MODULE I��I\ (SIGA-CRR/MCRR).This setting configures the module to`' reverse the polarity of its 24 Vdc output. Contact rating is 2.0 Wall plate.white A 1 gang) amp @ 24 Vdc(pilot duty). Personality Code 8 is assigned at the (( \\ factory. No user configuration is required. Vv a 1 Compatibility These modules are pad of EDWARDS's Signature Series intelligent Status LEDs = processing and control platform. They are compatible with EST3, a LED viewtn EST3X and i0 Series control panels. g ports 0l Warnings & Cautions This module will not operate without electrical power.As fires SIGA-MCR and SIGA-MCRR:mount the UIO motherboard frequently cause power interruption,we suggest you discuss inside a suitable EDWARDS enclosure with screws and washers further safeguards with your local fire protection specialist. provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard(see wiring diagram). UIO motherboard terminals Testing & Maintenance are suited for#12 to 418 AWG(2.5 rnm2 to 0.75 mm9)wire size. The module's automatic self-diagnosis identifies when it is defective and causes a trouble message. The user-friendly maintenance program shows the current state of each module --ulo Motherboard other pertinent messages.Single modules may be turned off(deactivated)temporarily,from the control panel.Availability of ®- _ maintenance features is dependent on the fire alarm system used. -- '--0---0 Scheduled maintenance(Regular or Selected)for proper system Plug-In(ulo) operation should be planned to meet the requirements of the Module Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and , 0. fl -44 ULC CAN/ULC 536 standards. . • _ Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically addresses each module. saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. [he loop controller identifies each device on the loop and assigns a"soft"address to each serial number. If desired,the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Page 2 of 6 E85001-0239 - .. -- Issue 1.1 • Typical Wiring Modules will accept #18 AWG(0.75mm2), #16(1.0mm2), #14 AWG(1.50mm2)and #12 AWG(2.5mm2)wire sizes. Note.Sizes#16 AWG(1.0mm2)and #18 AWG(0.75mm2)are preferred for ease of installation.See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Normally- Normally- Open Common Closed TB2 111 8 76 - , ..-- • • • Red LED (01) Green LED (Alarm/Active) 4 3 2 1 (Normal) TB1 III®al(Dal Notes DATA OUT(+)DATA IN(+) Refer to Signature Loop Controller Installation Sheet for wiring specifications. ' 0 NFPA 72 requires that the SIGA-CR/SIGA-MCR DATA IN(-) DATA OUT(-) be installed in the same room as the device it is From Signature Controller To Next Device controlling.This requirement may not apply in all or Previous Device markets.Check with your local AHJ for details. Q The SIGA-U106R and the SIGA-U102R do not SIGA-CR Control Relay come with TB14. 40 The SIGA-UIO6 does not come with TB8 through TB13. Supervised and power-limited. Normally Open Common Normally Closed Q If the source is nonpower-limited,maintain a space of 1/4 inch from power-limited wiring or use FPL,FPLP, FPLR,or an equivalent in accordance � with the National Electrical Code. /'\ n Maximum#12 AWG(2.5mm')wire. A2 3 4 Min.#18(0.75mm'). Data In+ 700, A 3 2 • 2 t • 1 TB7 TB14 No connections required for Data Out MCR.Other modules may require connections. • 4 6L 3 2 Green LED(Normal) 1 Red LED!Active) T*TiTB15 1,2 3 4,., A No connections required for MCR Other modules may require connections. SIGA-MCR Control Relay Page 3 of 6 E85001-0239 Issue 1.1 Typical Wiring Modules will accept#18 AWG(0.75mm'). 416(1.0mm2), #14 AWG(1.50mm2)and#12 AWG(2.50mm2)wire sizes. Note: Sizes#16 AWG(1.0mm2)and #18 AWG(0.75mm2)are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. AB4G AB4G AB4G Audible Base Audible Base Audible Base r i 6254A-003 EOL Relay I Listed 24 VDC + Nominal Power lilt II II II II II 0 II it II II Supply _ _ p L_ A I A A 4 r— I P JL_. A A L— _f li CR a CRR A SIGA-CRR CT1 a c o I1_Ml 1 E A Signature Controller © A Optional CR for disabling/disconnecting sounder base SIGA-MCRR SIGA-CRR Schematic SIGA-MCRR Schematic ' ® 0 0 Power h rower Out Eblanly Reverses Power in Power Our r + VAtc-a xtNOP;o Polarity reverses F O 6254A-003 ''i — + C when activated. m = G� q EOL Relay r f "I 1 Audible O — EN ct� required far Bases S supevision �8 �5 r s '¢ ¢ 'A 1� r: .41 l Jn v�i .�i. o a a I - llarl l bB. t1 Iti+.l+4l +il.f:.4: {i 4 3 '1 11111 ilii��� t ::: I--1rt Signature e L 7 Notes oats Dots Out + 1-1.1111111, _ • e Circuit O Refer to the Signature controller installation sheet for !Mr. For normal operationCT1 wiring. A dim roe General rive Alarm OPerotion • '• 0 One Pair of Wires(24 Vdc power). utuuLc listed +� 3 2 I 24 Vdc power — A, One Parr of Wires(Signature Data) sepsis or /1 11II. Single Wire(24 Vdc power). —� ' 1 t 234 ,1234 Q The SIGA-U106R and the SIGA-U102R do not come I Iel- ■u� ncpa with TB14. ern Ott U101a1 series motherboord �I W The SIGA-U106 does not come with TB8 through onto out+ •Lm f`��� =4 TB13. l krz Slgnvture a �: A 1 • A No mnnther m required for Supervised and power-limited. Data - *et4 MCRR.other modules may Circuit a ' i\ require connections. If the source;s nonpower-limited.maintain a space of 1/4 inch from power-limited wiring or use FPL. +� FPLP,FPLR,or an equivalent in accordance with theit ,onto�a_ - - \ Green LED Normal) National Electrical Code. y')� Red LED'Active/ 9 Maximum#12 AWG(2.5 male I wire:Minimum #1 R WM }.'. No connections required for AWG(0.75 male). Green LEo[Normal) I y-41 e a '1.11 MCRR.Other modules may 10 Fnd-Of-L me Relay must monitor and report power Red LED'Aaivet 4 require connections. supply trouble to control panel. A , A 11 Class B Data wiring may be'T-tapped" Optional rsRR or nca for No connections required for MCRR.Other disobling/disconn ecting an audible base. modules may require connections. Page 4 of 6 E85001-0239 Issue 1.1 - Specifications Catalog Number SIGA-CR • SIGA-MCR SIGA-CRR SIGA-MCRR Description Control Relay Polarity Reversal Relay • Type Code Personalty Code 8(Factory Set) Personality Code 8(Factory Set) Address Requirements Uses 1 Module Address Operating Current Standby- 75 pA Activated=75 pA Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Relay Type and Rating Form C,2 Amps 24 Vdc(pilot duty),0.5 Amps© 120 Vac and 0.25 Amps©220 Vac(220 Vac is non-UL) Not rated for capacitive loads. Mounting North American 21 inch i Plugs into U102R,UIO6R or ' North American 2/ inch Plugs into UIO2R,UI06R or (64 mm)deep 1-gang boxes I U106 Motherboards 1 (64 mm)deep 1-gang boxes U106 Motherboards and 1%z inch(38 rum)deep j and 11/2 inch(38 mm)deep 4 inch square boxes with ! 4 inch square boxes with 1-gang covers and SIGA- 1-gang covers and SIGA- MP mounting plates i MP mounting plates Construction&Finish High Impact Engineering Polymer Storage and Operating Operating Temperature:32°F to 120°F(0°C to 49°C) Environment Storage Temperature:-4°F to 140°F(-20°C to 60`C)Humidity:0 to 93%RH LED Operation On-board Green LED-Flashes when polled On-board Red LED-Flashes when in alarm/active Compatibility Use With:Signature Loop Controller Agency Listings UL,ULC,CSFM,MEA Ordering Information Catalog Number Description Ship Weight-lbs (kg) SIGA CR Control Relay Module(Standard Mount) 0.410.15) SIGA MCR Control Relay Module(U10 Mount) 0.18(0.08) SIGA-CRR Polarity Reversal Relay Module(Standard Mount) 0.4 10.15) SIGA-MCRR Polarity Reversal Relay Module(UIO Mount) 0.18(0.08) Related Equipment 27193-11 Surface Mount Box-Red, 1-gang 1 (0.6) 27193-16 Surface Mount Box-White, 1-gang 1 (0.6) SIGA UIO2R Universal Input-Output Module Board w/Riser Inputs-Two Module Positions 0.32(0.15) SIGA UIO6R Universal Input Output Module Board w/Riser Inputs Six Module Positions 0.62(0.28) SIGA U106 Universal Input-Output Module Board Six Module Positions 0.56(0.25) SIGA-AB4G Audible(Sounder)Detector Base 0.3(0.15) Accessories _r-►- MFC-A Multifunction Fire Cabinet-Red,supports Signature Module Mounting Plates 7.0(3.1) SIGA-MB4 Transponder Mounting Bracket(allows for mounting two 1-gang modules in a 2 gang box) 0 4(0.15) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.10) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) Page 5 of 6 E85001 -0239 Issue 1.1 Signature Series Overview r The Signature Series intelligent analog-addressable system from EDWARDS is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels,and user-friendly maintenance and service tools.Analog information from equipment connected to Signature devices is Contact us gathered and converted into digital signals.An onboard microprocessor in each Signature Phone: 800-655-4497(option 4) device measures and analyzes the signal and decides whether or not to input an alarm. Email: erivrards.tirmtticita ercom The microprocessor in each Signature device provides four additional benefits-Self- Website EtivvorrNiresareltio diagnostics and History Log,Automatic Device Mapping, and Fast, 8985 Town Center Pkwy Stable Communication. Bradenton,FL 34202 Self-diagnostics and History Log-Each Signature Series device constantly runs self- © 2020 Carrier checks to provide important maintenance information.The results of the self-check are All rights reserved. automatically updated and permanently stored in its non-volatile memory.This information is accessible for review any time at the control panel, PC,or using the SIGA-PRO Signature Program/Service Tool.The information stored in device memory includes: •Device serial number,address,and type •Time and date of last alarm • Most recent trouble code logged by the detector - 32 possible trouble codes may be used to diagnose faults. Automatic Device Mapping-The Signature Data Controller(SDC)learns where each device's serial number address is installed relative to other devices on the circuit.The SDC keeps a map of all Signature Series devices connected to it.The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support.the wired circuits between each device can be examined. Layout or"as-built" drawing information showing branch wiring(f-taps), device types and their address are stored on disk for printing hard copy.This takes the mystery out of the installation.The preparation of as-built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: • Unexpected additional device addresses • Missing device addresses •Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configuration and are indicated during device mapping. 0 Page 6 of 6 E85001-0239 Issue 1.1 Open-area Smoke Imaging Detection Features (OSID)by Xtralis is a new innovation in projected beam smoke detection Maximum detection range of 200 m technology. By using advanced dual (656 ft)for the OSI-1 D wavelength projected beams and optical Dual wavelength LED-based smoke imaging technology for early warning t i detection smoke detection,OSID provides a low- • Optical imaging with CMOS imaging cost, reliable and easy-to-install solution chip that overcomes typical beam detection • On-board event log for fault and alarm issues such as false alarm incidents and diagnostics alignment difficulties. r u • High tolerance to false alarm due to Unique Detection Technology building movement • The OSID system measures the level of smoke entering beams of light projected over High tolerance to transient dust,steam an area of protection.A single OSID Imager can detect up to seven Emitters to provide and intrusion of solid objects a wide coverage area.Two innovations in smoke detection technology have been • Easy alignment with large adjustment developed for the revolutionary OSID smoke detector: and viewing angles Dual Wavelength Particle Detection • No need for precise alignment • Tolerant of alignment drift The beam projected from each Emitter contains a unique sequence of ultraviolet(UV) • Automatic commisioning in under ten and infrared(IR)pulses that are synchronised with the Imager and enable the rejection minutes of any unwanted light sources. • Simple DIP switch configuration By using two wavelengths of light to detect particles,the system is able to distinguish • between particle sizes. The shorter UV wavelength interacts strongly with both small Simple and easy maintenance and large particles while the longer IR wavelength is affected only by larger particles. requirements Dual wavelength path loss measurements therefore enable the detector to provide • Three selectable alarm thresholds repeatable smoke obscuration measurements,while rejecting the presence of transient • Status LEDs for Fire,Trouble and Power dust particles or solid intruding objects. • Conventional alarm interface for Optical Imaging with a CMOS Imaging Chip straightforward fire system integration An optical imaging array in the OSID Imager provides the detector with a wide viewing angle to locate and track multiple Emitters Consequently, the system can tolerate a Listings/Approvals much less precise installation and can compensate for the drift caused by natural shifts in building structures • UL • Optical filtering, high-speed image acquisition and intelligent software algorithms also ULC enable the OSID system to provide new levels of stability and sensitivity with greater • FM immunity to high level lighting variability. • CSFM Operation • NF-SSI(AFNOR)* • CE—CPR&EMC Status information(Fire Alarm,Trouble and Power)is communicated through the • VdS Imager via Status LEDs,dedicated Trouble and Alarm relays, and the Remote Indicator interface.Specific Trouble(Fault)conditions are identified through coded flashes of the • BOSEC Trouble LED • CCCF An internal heating option is also provided on the Imager to prevent condensation on • ActivFire the optical surface, and a reset input enables an external signal to reset the device. • VNIIPO Simple Installation and Maintenance The OSID system consists of up to seven Emitters for the 90° Imager unit, located ' For more information on the NF SSI mark along the perimeter of the protected area. and an Imager mounted o (Fire Safety System), you can consult g opposite Each the AFNOR Certification website:www. component can be mounted directly to the surface or can be secured with the supplied mountingbrackets. Batterymarque-nf corn powered Emitters with three or five years battery life are also available to reduce installation time and cost. On the Imager, a termination card provides all field wiring terminals, and DIP switches enable the user to configure the detector for particular applications. _ ,_ , � x f � .)* a r T ' ug r.F� t '"�) ' .�� U2 k� H4If' s� i 0M . �k�{ 4 . n r : a' C >e , i d x. k r cayt1r4, r116, � y� { t �.t,Itia v xi : sk -7" a -A � «1*' 3 As ,--- fi 9 ,-"4' r - ti �: a 00V 0,1 � Alignment of the Emitter is simply achieved using a laser alignment tool to rotate the Specifications optical spheres until the laser beam projected from the alignment tool is close to the Imager. Supply Voltage 20nal) The Imager is aligned in a similar way so that its Field of View(FOV)encompasses Imager to CurrentDC(2 VDC mnoption all Emitters.A Trouble or Fault will be indicated if an Emitter is missing or outside the consumption Imager field of view. Nominal(at 24 VDC). 8mA(1 Emitter) The OSID system is highly tolerant to transient dust and dirt and requires little 1OrnA(7 Emitters) maintenance in practice. Preventative maintenance is limited to occasionally cleaning Peak(at24 VDC)during training mode 31mA the optical faces of the detector components. Emitter Current Consumption The Imagers are equipped with an onboard event memory for diagnostic purposes. Wired Version(at 24 VDC)' 350pA Std Power,800pA High Power Connecting the OSID Diagnostic tool allows users to download this memory log for Battery Version(1 9-3.2 VDC) further alarm and fault analysis and troubleshooting. OSE-RBA Built-in Battery: -SP Version:5-year battery life Configuration Options for EN54-12 Installations -HP Version:3-year battery life OSID systems may be configured to suit a range of detection spaces by selecting the Battery life time only valid for use at room number of Emitters and type of Imager. Each type of Imager differs by the lens used in temperature. the unit,which determines the field of view and range of the system. Field Wiring Y -h Field of View Detection Range .... Max. Cable Guage:0.2-4mm`(26-12 AWG) Alarm Threshold Levels: Imager Standard Power High Power Number Low-Highest sensitivity/earliest alarm: Horizontal Vertte al — of 20%(0.97 dB) Mu1 Max Min Max Emitters Medium-Medium sensitivity. t 30 w 00 I:, 'a0111 01.02 L 10L w 200 in tg5ote I I 35%(1.87 dB) (328 ft) 169 m(5901)"' I High-Low sensitivity. 96' 80' 48 3 6 rn ft) 1 °34 m(111 ft) 12 m 66 m/50 m' 7 50%(3.01 dB) -+.__ !i ,-„ __, (39 ft) (223 ft/164 ft) Highest-Lowest sensitivity,Industrial Mode: 'Distance with OSE-HP-01. 65%(4.56 dB) "Maximum Distances measured for the Center Field of View of the Imager.For more details on distances for the Do not use Heater nor Dust Rejection if OSI-90 is set Imager.see the Oslo Product Guide. a165%sensitivity. —180m(590 ft.)for VdS approved installations- Adjustment Angle ±60°(horizontal) Emitter/ Imager Dimensions ±15°(vertical) Maximum Misalignment Angle ±2° Dimensions(WHO) '30 L091'2. mIG t6] IL7 Emitter I Imager: _! - 208mm x 136mm x 96mm ). 1--) I ry� tid �j' (8.19 in.x 5.35 in.x 3.78 in.) - el �� .q - L Operating Conditions* JI F Temperature' et -10°C to 55`C(14°F to 131 °F)- 1 -" _ �� � Humidity:10 to 95%RH(non-condensing) cg mp.e., 1`—_us mm(s xJ ' --) Please consult your Xtraus office for operation outside these parameters. , --,- Storage Conditions(non-operational) ‘, '1 i Humidity'Dry(<95%) c �� Temperature:0`to 85'C EMust not exposed to sunlight or other radiation sources. �� :.:�_ I IP Rating -- -_i IP 44 for Electronics IP 66 for Optics Enclosure Ordering Codes Status LEDs OSh10 Imager-7"coverage RTS751KIT Imager Reset Station Mount SurfaceFire Alarm(Red) y OSI-90 Imager-80°coverage RTS151KEY linger Reset Station Flush Mount Trouble/Power(Br-color Yellow!Green) OSE-SP.01 Emitter.Alkaline hattery OSP-001 ETD!Cable 1.5 m Event log OSE-SPW Emitter-Standard Power.VNred OSP-002 Laser Alignment tool 10,000 events OSE-HP.01 Emitter-High power alkaline battery DSP-003 Acrylic test filler-pack of 10 Color - , OSE.HPW Emitter.I Loh Power Wired OSP-003-200 Acrylic test filter-bulk pack(200 units) White.RAL9003 OSID-EHI Imager environmental housing IP66 OSE-RBA Emitter.Spare alkaline battery pack OSIO.EHE Emitter environmental housing l P66 OSE-RBL Replacement Lithium Ion Kit Approvals Compliance OSE-ACF Asti-concensation film for Emitters g). OSID-INST OSID Installation Kit Please refer to the Product Guide for details OSEH-ACE Anti-condensation film for OSID-EHE and VKT-301 Presentation Kit regarding compliant design,installation and OSID-EHI environmental housings OSID-WO Wre Guam commissioning. Pme°a�t u=eo mr°se barn a°<ro n ec t z n°'co r sire)ratz,:aftsre wt ;-tos ? ., xto--'fatifs6craMag,gytyttftrgYrr" 1 e!,:tst31 www.xtralis.com UK and Europe-44 1442 242 330 The Americas s 1 800 229 4434 Middle East-962 6 588 5622 Asia st36 10 56697101 Australia and New Zealand+61 3 9936 7000 T- o o 'o r g e ly P r of a 1 tM1 1te r re,o reltatAtt :he Il t i docLment f t t aat to ehaeaedesigos Ot IFor,,,ette, tln blp r m r t E or F d tl Il C pl a J. N 1f t l P[ed t r -to .S Ir ,g"Tr S YF E C C(`C aS p ! 1 d k a gt pt d -k t r,t.," r+. x. 1 r Ir v a rna t o- b e t b e pec..E roI..F .1 Yo. °Sr I1 d.c. cC ,.l cpnst.°tt. tit^ tend OlFeplot Fp 5ethe nvmf ana k .d , Thug _b,. 0y I" ob %.. terorn.ep blic maul.dstnbuto lianster sell enHtry of pyhli 1 o rr. O accrner Ib lh -rp,e-.oro �r _.-enla ..o- itcwnbar 2a'.� Part too.295T3 � xrµ", " `" SAE 10 — FDB FIRE ALARM ,. DOCUMENTS BOX SD Fire has you covered When it comes to your fire protection accessories.Our Fire Alarm Documents Box is top of the line. Programs • CAT 30 secured locking door • Door with notes sticker #:• • Removable document holder • Embossed: ti 'xi —Key ring hooks —Business card holder U , x s r r,-0..N„n —CD case slot ; � m,. • Space for can of detector test gas b e • • t • RECHARGABLE SEALED LEAD ACID BATTERY PRODUCTS DATA t i,it:: `. ELK=1 2 180e 12V, 18Ahr FEATURES • Valve regulated,non-spillable construction • UL recognized component • Two year over-the-counter warranty UL Recognized Component APPLICATIONS gpn • Back-up battery for security alarm systems,fire alarm systems and access control systems wr • Emergency lights ; `, • Lighted exit signs �- ?4. • Uninterruptible power supplies• Other general purpose use SPECIFICATIONS DIMENSIONS Nominal Voltage 112 Volts Terminals Rated Capacity 18 Ah(20 hour rate) 7711 t^ 12,-,,- z l Nominal Capacity(77°F,25°C) ; ® N 'MI 1 { 20 hour rate(0.9A) 18 Ah 10 hour rate(1.67A) 16.74 Ah 5 hour rate(3.1 A) 15.5 Ah n 1 hour rate(10.4 A) 10.4 Ah t Effect of Temperature on Note:Prolonged exposure to extreme temperatures can Capacity(20hourrate) hove long torso effects on lottery performance 104°F(40°C) 102% 77"F(25"C) 100% 167 as 32"F(0"C) 85% 5°F(-15°C) 65% Charge Constant Voltage Cycle 14.4V-14.8V at 77°F(25°C) Initial Charging Current 5.1 A Max [• 181 xi Urns s=mm Standby 13.5V-13.8V at 77"F(25°C) Weight(Approximate) 11.44 lbs(5.2 kg) Length 7.13"(181 mm) Height 6.57"(167mm) Terminals Ri-MS bolt&nut Width 3.03"(77 mm) CAPACITY RETENTION CHARACTERISTICS DISCHARGE CHARACTERISTICS(68°F,20°C) (41 ` "''__►` (4t°F). C,.arging before use p rammmenneo. 13 II :: i i (68F)t' u • "„ 0 10 _.. o..c aorc oosc_ s .p, - - , a25C .5 N, 4i 3 a recommended a9eisnot C 9 ._. s __ _ __ } 1..___.___ recomme�ae°arq:an o. 40 > ,� it p°f' y" resin!�n toss or wu.capza!y. E i r e —_ T i ac 2c t lc �� 0 2 4 6 8 10 12 U I 1 2 3 5 10 20 30 60 2 3 5 10 20 Storage Period(Months) MINI - HOURS . Discharge Time For more information,including details on recycling ELK batteries and MSDS for this product,please visit www.elkproducts.com or call us at(828)397-4200.