Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Specifications
PATRIOT 4708 NE MINNEHAHA ST VANCOUVER,WA 98661 FIRE PROTECTION TEL(360)699-4403 FAX(360)699-4485 IcctricaI Equipment Submittal JOB # 31-1601 TACOMA,WA OFFICE www.patriotfire.com SPOKANE,WA OFFICE TEL(253)926.2290 pATRIFP099CF TEL(509)926-3428 FAX(253)922-6150 FAX(509)926-3708 P POTTER BELLS 6 The Symbol of Protection PBA-AC&PDC-DC Features • Listed for indoor and outdoor use ' 0 ) • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4"box • Low current draw • High dB output al _ • AC and DC models 0 • DC models are motor driven,polarized,and have built in transient protection for supervised alarm circuits • Available in 6",8"and 10"sizes 49* 4//t (16) (21) APPROVED r .t *ULC on PDC-DC Only Description Technical Specifications These vibrating type bells are designed for use as fire or general Dimensions 6"(150mm),8"(200mm)and 10"(250mm) signaling devices.They have low power consumption and high decibel Cover:Steel Finish:Red Powder Coat ratings.The unit mounts on a standard 4"(101mm)square electrical Base:non-corrosive composite material box for indoor use or on a model BBK-1 or HC-BB weatherproof Enclosure All parts have corrosion resistant finishes backbox for outdoor applications.Weatherproof backbox model BBK- Model BBK-I or He-BB weatherproof backbox(optional) 1 or HC-BB,Stock No. 1500001. 24VAC Voltages Available 120VAC Notes I2VDC(10.2 to 15.6)Polarized 24VDC(20.4 to 31.2)Polarized 1. Minimum dB ratings are calculated from integrated sound pressure Indoor or outdoor use(See Note 1) measurements made at Underwriters Laboratories as specified in Ei1vtronmental -40°to 150°F(-40°to 66°C) Limitations UL Standard 464. UL temperature range is-30°to I50°F(-34°to (Outdoor use requires weatherproof backbox.) 66°C) AC Bells-4 No.18 AWG stranded wires Termination DC Bells-18 AWG stranded wire 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels Service Use NFPA 13,72,local AHJ in an actual installation. 3. ULC only applies to PDC DC bells. *Specifications subject to change without notice. AWARNING ; Size inches Voltage Model Stock Current Typical dB at Minimum dB at z • ( ) Number Number (Max.) 10 ft.(3m)(2) 10 ft.(3m)(1) 6(150) I2VDC PDC-6-12 1750500 200mA 96 76 • Installation must be performed by qualified personnel and in accordance with all 8(200) I2VDC PDC-8-12 1750502 .200mA 96 77 national and local codes and ordinances. • Shock hazard.Disconnect power source before servicing.Serious injury or death 10(250) I2VDC PDC-10-12 1750504 .200mA 96 78 could result. 6(150) 24VDC PDC-6-24 1750501 .20mA 95 77 • Risk of explosion.Not for use in hazardous locations.Serious injury or death 8(200) 24VDC PDC-8-24 1750503 20mA 83 79 could result. 10(250) 24VDC PDC-10-24 1750505 20mA 85 80 :. ....,.,,... 6(I50) 24VAC PBA246 1806024* .17A 91 78 -�.:,. e a WAR N I N G 8(200) 24VAC PBA248 1808024. .17A 94 77 10(250) 24VAC PBA2410 1810024* .17A 94 78 In outdoor or wet installations,bell must be mounted with weatherproof backbox, 6(I50) 120VAC PBA1206 1806120" .05A 92 83 BBK-1 or HC-BB. Standard electrical boxes will not provide a weatherproof 8(200) 120VAC PBA1208 1808120* .05A 99 84 enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an electrical hazard. 10(250) 120VAC PBA12010 1810120* .05A 99 86 • All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 5400777-REV A • 12/20 PAGE I OF 2 P POTTER BELLS e The Symbol of Protection PBA-AC&PDC-DC Installation The bell shall be installed in accordance with NFPA 13,72,or local AHJ.The top of the device shall be no less than 90"AFF and not less than 6"below the ceiling. 1. Remove the gong. 2. Connect wiring(see Fig.3). 3. Mount bell mechanism to backbox(bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction). WARNING Weatherproof Backbox Dimensions _- Inches (mm) Failure to install striker down will prevent bell from ringing. MODEL BBK-I OR HC-BB Fig 2 Bell Dimension Inches (mm) fa Fig I I 0 5l/a" — 3 3/8" 5" (lab mm) (86mm) (127mm) 10" (250 mm)[ 1 ———— 1200 m T6,, L(1ntl3/g^(ISO m) _L—.j— (86mm) (al mm) 4114" (108 mm) 211/16"(68 mm) (' •I�. a /DWG0776-1 • D Wiring Rear View Fig 3 D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (IN) RED (OUT) WHITE (IN) WHITE (OUT) FROM CONTROL PANELtr, TO NEXT BELL FROM CONTROL PANEL101,11 OR OR END—OF—UNE OR PRECEDING BELL RESISTOR PRECEDING BELL BLACK (IN) _� BLACK (OUT) BLACK (IN) -�, BLACK (OUT) CAUTION' CAUTION' WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN- NOTES: NOTES: 1. OBSERVE POLARITY TO RING D.C. BELLS. 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY 2. RED WIRES POSITIVE (+). AFTER LAST BELL. 3. BLACK WIRES NEGATIVE (-). 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS . 4. EOL RESISTOR IS SUPPLIED BY FIRE ALARM CONTROL PANEL. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 5400777-REV A • 12/20 PAGE 2 OF 2 P P011ER VSR VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL,CUL and CSFM Listed,FM Approved,LPCBApproved,For CE Marked(EN12259-5)/VdS Approved model use VSR-EU Service Pressure: 450 PSI(31 BAR)-UL Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM)-UL Maximum Surge: 18 FPS(5.5 m/s) Contact Ratings: Two sets of SPDT(Form C) 10.0Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min.at 24VDC �F Conduit Entrances: Two knockouts provided for 1/2"conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F-120°F,(4.5°C-49°C)-UL • Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 Specifications subject to change without notice. • One or two family dwelling NFPA-13D Ordering Information Residential occupancy up to four stories NFPA-13R Nominal Pipe Size Model Part Number National Fire Alarm Code NFPA-72 2" DN50 VSR-2 11444 Q WAR N I N G 21/2" DN65 VSR-2 1/2 1144425 25 3" DN80 VSR-3 f 14440? • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. 3 1/2" - VSR-3 1/2 1144435 • Shock hazard.Disconnect power source before servicing.Serious 4" DN100 VSR-4 1144404 injury or death could result. • Risk of explosion.Not for use in hazardous locations.Serious 5" VSR-5 1144405 injury or death could result. 6" DNI50 VSR-6 1144406 8" DN200 VSR-8 1144408 CAUTION Optional: Cover Tamper Switch Kit,stock no.0090148 Waterflow switches that are monitoring wet pipe sprinkler systems shall Replaceable Components:Retard/Switch Assembly,stock no. 1029030 not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air,or short retard times. Important: This document contains important information on the installation and operation of the VSR waterflow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. General Information Enclosure The Model VSR is a vane type waterflow switch for use on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems.It is UL Listed for use on a steel pipe;schedules 5 through 40, die-cast housing. The cover is held in place with two tamper resistant sizes 2"-6"and is UL Listed and FM Approved for use on steel pipe; screws which require a special key for removal. A field installable schedules 10 through 40, sizes 2"thru 8"(50 mm thru 200 mm).LPC cover tamper switch is available as an option which may be used approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering to indicate unauthorized removal of the cover. See bulletin number Information chart. 5401 103 for installation instructions of this switch. The VSR may also be used as a sectional waterflow detector on large systems.The VSR contains two single pole,double throw,snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM(38 LPM)or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.#5401146-REV M PAGE 1 OF 4 11/15 P PC1fTER VSR VANE TYPE WATERFLOW e The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6"(15 cm)of a fitting which changes the direction of the waterflow or within 24" (60 cm)of a valve or drain. NOTE:Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill(see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole;do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow.Take care not to damage the non-corrosive bushing in the saddle.The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. I).The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle.Failure to follow these instructions may prevent the device from operating and will void the warranty.Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm.If an alarm is not desired,a qualified technician should disable the alarm system. Fig.I Retard Adjustment II% DO NOT LEAVE COVER OFF FOR I�� r ANExrENDEnrsRronoFruuE The delay can be adjusted by rotating the retard adjustment knob from ��.� ,�IJ� 1 0 to the max setting(60-90 seconds).The time delay should be set at 1.�'$1 the minimum required to prevent false alarms .'Illr 7� \.`6l1� O. : TIGHTEN NUTS �r All /111� ALTERNATELY • `,. ��j-7L / CAUTION �� ill4€11 Hole must be drilled perpendicular to the pipe and vertically centered. 10 14400 -' Refer to the Compatible Pipe/Installation Requirements chart for size. /r MOUNT ON PIPE Correct Incorrect - . ARROW ON SADDLE N I POINTS IN DIRECTION d______ --EliO (3 "0, OF WATERFLOW VIII 1U1Ir WilliV ROADDLE IN DIRECTION OF OPPOLLSITEP DIRECTION ADAPTERADAPTER WATERFLOW OF WATERFDLOW% g water activates -...1 �- 20mm almm MAX device in one direction only.) DN50 ONLY 1 USE(2)4180162 ADAPTERS AS SHOWN ABOVE _v/ 111 aW61116-11 DWG u46.1r Compatible Pipe/Installation Requirements Model Nominal Pipe Nominal Pipe Pipe Wall Thickness Hole Size U-Bolt Nuts Size O.D. Lightwall Schedule 10(UL) Schedule 40(UL) BS-1387(LPC) DN(VDS) Torque inch mm inch nun inch mm inch mm inch mm inch mm inch mm inch mm ti-lb n-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25+.125/- VSR-2 1/2 2.5 - 2.875 73.0 .084 2.134 0.120 3.05 0.203 5.16 - - - - 33.0i2.0 .062 VSR-2 1/2 - DN65 3.000 76.1 - - - - - - 0.142 3.6 0.102 26 VSR-3 3 DN80 3.500 88.9 .083 2.108 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 VSR-3 1/2 3.5 - 4.000 101.6 - - 0.120 3.05 0.226 5.74 - - - - 20 27 VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 2.00+.125 50.8+2.0 VSR-5 5 - 5.563 141.3 - - 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DNB() 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 - - 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 NOTE:For copper or plastic pipe use Model VSR-CF. • PRINTED IN USA MFG.#5401146-REV M PAGE 2 OF 4 I1/15 P POTTER VSR VANE TYPE WATERFLOW ® The Symbol of Protection ALARM SWITCH WITH RETARD Fig.2 Fig.3 Fig.4 Switch Terminal Connections Clamping lb remove knockouts:Place screwdriver at Break out thin section of cover when Plate Terminal inside edge of knockouts,not in the center. wiring both switches from one conduit 01 entrance. - V*. :10, ,i,1 �I�,./ 6� .�-Ni 016 D _3166 r- 4440 IAA; �'ll �� `�� ;�/ !\ ��I�1 An uninsulated section of a single conductor should not be looped `� «. �y�l i�a`�- around the terminal and serve as two separate connections The j� y�� wire must be severed,thereby providing supervision of the NOTICE f4V40° connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device Do not drill into the base as this creates .�/!G, OWL.11.6-„ inoperable risking severe property damage and loss of life. metal shavings which can create ��10 Do not strip wire beyond 3/8"of length or expose an uninsulated electrical hazards and damage the conductor beyond the edge of the terminal block.When using device.Drilling voids the warranty. stranded wire,capture all strands under the clamping plate. CONNECTOR Fig.5 Typical Electrical Connections NEUTRAL FROM BELL _:; BREAKER NEUTRAL FROM BELL f.l n Ill )BREAKER 56. I ' Notes: UNE FROM BREAKER 8 ECL(End Of Line Resliser) 1. The Model VSR has two switches,one can be used to operate a central station,proprietary or remote signaling unit,while the other contact —1111 is used to operate a local audible or visual annunciator. - 2. For supervised circuits,see"Switch Terminal Connections" I�'�- I Iel drawing and warning note(Fig.4). �t ■ ■ NOTE.When connecting to a UL Listed control panel,use the panel's ., ei resistor value for circuit supesvhlon ��h Irk rim Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently). If provided,the inspector's test valve shall always be used for test purposes.If there are no provisions for testing the operation of the flow detection device on the system,application of the VSR is not recommended or advisable. A minimum flow of 10 GPM(38 LPM)is required to activate this device. NOTICE Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig.6 Mounting Dimensions 5 56 in Fig.7 3.50m 2.00m ' (1412 mm)—„ (89.0 min) (50.8 mm) " ' GREEN GROUND 2,34 in / SCREWS (59.4 n n) ■� II I'..,.. i a PI'EDIA. d e.(l�, UBOLT NUT __ '< a 1 5.25m WM U-BOLT WASHER s1��1 II I. (+ 33.4 min) :Ali II� I a p. 0 ) PIPE SADDLE i� T �I ���� 01,PIPE ■!`,' PLASTIC PADDLE , I IU—vS 9 DwG.nrr. U-BOLT NOMINAL PIPE DIA.+1.75 in(+44.5 MM)FOR DN 50-DN 652-2.5m '._� • NOMINAL PIPE DIA.+2.125 in(+54.0 MM)FOR ON 80-DN 2003-8 in . O,, o'.vc nAG+s PRINTED IN USA MFG.#5401146.REV M PAGE 3 OF 4 11/15 • P POTTER VSR VANE TYPE WATERFLOW ® The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found,replace the detector. The VSR waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable.In the unlikely event that either component does not perform properly,please order replacement retard switch assembly stock#1029030(see Fig.8).There is no maintenance required,only periodic testing and inspection. Retard/Switch Assembly Replacement(See Fig.8) NOTICE The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell(if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the(2)mounting screws holding retard/switch assembly to the base.Do not remove the(2)retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly.Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re-install the(2)original mounting screws. 8. Reconnect all wires.Perform a flow test and place the system back in service. Fig 8 REMOVE(2)ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE BREAKOUTTHIN SECTIONOFCOVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2)ORIGINAL MOUNTING / CREWS RETARD/SWITCH ASSEMBLY -��Ir l� \ t� I -- ,m, ��„ /J „,." ., �`� (2)LOCATING PMS I I � 7a.. (2)LOCATING PIN I DO NOT REMOVE I 1 BOSSES IN BASE\ (2)RETARD HOUSING I n, 1P I SCREWS L r�� „•- • 1, !'^'r "I BAS .■■ �,� * I 1 r-, r� , pc), Nu" DWG#1146-10 Removal of Waterflow Switch • To prevent accidental water damage,all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector,then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers,roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. PRINTED IN USA MFG.#5401146-REV M PAGE 4 OF 4 11/15 8/22/22, 12:14 PM 1 HP S175 Series HD I Fire Protection I C-Aire Compressors HOME/COMPRESSORS/ FIRE PROTECTION AIR COMPRESSORS/ HEAVY DUTY/1 HP S175 SERIES HD 0 I I 1111111111111111 0. C., ,. . . �4111 _ -- 'I "'+-_ ' 4 µ CC-ARE https://cairecompressors.com/product/1-hp-s 175-series-hd/ 1/5 8/22/22,12:14 PM 1 HP S175 Series HD I Fire Protection I C-Aire Compressors 1 HP S175 SERIES HD PRODUCT NUMBER S175H PRODUCT SPECS 1 Horse Power 3 Gallons 2.5 CFM @ 10 PSI Single or Three Phase 115 or 230 or 460 Volts Horizontal Tank or Floor Mount Standard 70-100PSI / Special Order 30-40PSI 1/2" NPT Outlet 27"x 12" x 22" 80 lbs Shipping Weight STANDARD FEATURES Fills 208-gallon system to 40 psi in less than 30 minutes Appropriate for single or multiple-valve systems Tank drain and full synthetic oil included Vibration absorbing feet included Compatible with all regulator air maintenance devices Great for older sprinkler systems https://cairecompressors com/product/1-hp-s175-series-hd/ 2/5 8/2222, 12:14 PM 1 HP S175 Series HD I Fire Protection I C-Aire Compressors ETL listed 12-month unit warranty Heavy Duty series includes a 3-year warranty on the pump CALCULATE CAPACITY CALCULATE LEAKS DESCRIPTION VIDEOS DOCUMENTS PARTS WARRANTY SIGN UP FOR PRODUCT UPDATES Email Industries Fire Protection Automotive/Other https://cairecompressors.com/product/1-hp-s175-series-hd/ 3/5 Lakeside Supply Company r 210_941_6800 Pipe Fittings 1Y3"'1VIWA* .-n 4':4n'''..., lopo.........i...4._4 C;; ,°4--....' 4.- ,..„ .............41I 4414: _,IOW CI)`„ - l,L, -„ ..1 Iz A 114 MALLEABLE IRON CLASS 150 (STANDARD) 90°Elbow Size A Weight(lbs) 45°Elbow Size C Weight(lbs) Figure 1101 (NPS) (in) black galv. Figure 1102 (NPS) (in) black galv. 1/8 11/16 .06 .07 1/8 11/16 .06 .08 1/4 13/16 .11 .12 1/4 3/4 .11 .11 4 WI 3!8 15/16 .17 .17 3/8 13/16 .16 .18 1/2 1-1/8 .26 .27 l 1/2 7/8 21 .24 3/4 1-5/16 .38 .43 3/4 1 .37 .39 1 1-1/2 .63 .65 1 1-1/8 .54 .57 1-1/4 1-3/4 .96 .94 1-1/4 1-5/16 .86 .87 1-1/2 1-15/16 1.30 1.34 1-1/2 1-7/16 1.13 1.17 2 2-1/4 2.06 2.01 2 1-11/16 1.71 1.85 I-'-AR 2-1/2 2-11/16 3.54 3.64 C> 2-1/2 1-15/16 2.78 2.90 3 3-1/16 5.20 5.35 s 3 2-3/16 4.48 4.58 ----i- 1- 3-1/2 3-7/16 7.10 7.19 .`- 4 2-5/8 7.20 7.36 4 3-13/16 8.95 9.37 1C 5 3-1/16 11.46 11.75 5 4.1/2 13.90 14.50 6 3-7/16 17.24 17.65 6 5-1/8 23.00 23.50 45°Street Elbow Figure 1104 90°Street Elbow Size A J Weight(lbs) Straight:Figure 1103 (NPS) (in) (in) black gale. �� Reducing:Figure 1103R , 1/8 11/16 1 .06 .06 1/4 13/16 1-3/16 .11 .12It -- -T- 3/8 15/16 1-7/16 .17 .18 - K .: 1/2 1-1/8 1-5/8 .24 .26 _i_ 3/4 1-5/16 1-7/8 .41 .42 -i 1 1-1/2 2-1/8 .62 .64 1-1/4 1-3/4 2-7/16 1.10 1.14 Size C K Weight(Ibs) (NPS) (in) (in) black gale. 1-1/2 1-15/16 2-11/16 1.44 1.55 1/8 11/16 7/8 .06 .07 2 2-1/4 3-1/4 2.85 2.73 1/4 3/4 15/16 .10 .11 2-1/2 2.11/16 3-7/8 4.00 4.05 3/8 13/16 1 .14 .14 i A--•1 3 3-1/16 4-1/2 6.06 6.26 1/2 7/8 1-1/8 .20 .21 4 3-13/16 5-11/16 9.87 11.07 3/4 1 1-5/16 .33 .34 1/2 x 3/8 1-1/16 1-9/16 .23 .25 1 1-1/8 1-7l16 .52 .53 3/4 x 1/2 1-3/16 1-3/4 .32 .36 1-1/4 1-5/16 1-11/16 .84 .87 M J 1 x 3/4 1-3/8 2-1/16 .54 .56 1-1/2 1-7/16 1-7/8 1.21 1.27 __� 1-1/4 x 1 1-9/16 2-5/16 .86 .89 2 1-11/16 2-1/4 1.94 1.95 - 1-1/4 x 3/4 1-7/16 2-1/4 .75 .77 1-1/2 x 1-1/4 1-13/16 2-9/16 1.18 1.31 First size 1-1/2 x 1 1-5/8 2-1/2 1.08 1.11 denotes female end 2 x 1-1/2 2 2-15/16 1.85 1.88 wwiw Jake idesu ply. m 93 Pipe Fittings Lakeside Supply Company 11 : 216-941-680 0110AISM.4; MALLEABLE IRON CLASS 150 (STANDARD) Size X Z Weight(Ibs) Reducing Elbow (NPS) (in) (in) black Figure 1101 R galvanized 1/4 1/8 3/4 3/4 0.10 0.1010 3/8 1/8 13/16 7/8 0.12 0.13 1/4 7/8 15/16 0.14 0.15 1/2 1/4 1 1 0.19 0.20 3/8 1-1/16 1-1/16 0.21 0.22 •it 3/4 1/4 1.1/8 1-1/8 0.26 0.28 °- 3/8 1.1/8 1-1/8 0.29 0.30 1/2 1-3/16 1-1/4 0.39 0.40 1 3/8 1-3/16 1-1/4 0.41 0.42 1/2 1-1/4 1-3/8 0.46 0.47 3/4 1-3/8 1-7/16 0.55 0.58 -->r1 1-1/4 1/2 1-3/8 1-9/16 0.62 0.64 3/4 1-7/16 1-5/8 0.71 0.73 1 1-9/16 1-11/16 0.86 0.9 -i -- 1-1/2 3/4 1-1/2 1-3/4 0.83 0.85 I 1 1-5/8 1-13/16 1.00 1.05 X 1-1/4 1-13/16 1-7/8 1.17 1.18 I 2 3/4 1-5/8 2 1.3 1.32 1 1-3/4 2 1.35 1.45 1-1/4 1-7/8 2-1/8 1.53 1.55 1-1/2 2 2-1/8 1.75 1.78 2-1/2 1.1/2 2-3/16 2-1/2 2.32 2.55 2 2-7/16 2-5/8 3.00 3.00 3 2 2-9/16 2-15/16 3.75 3.91 2-1/2 2-13/16 3 4.00 4.05 4 3 3-5/16 3-5/8 7.87 7.95 Straight Tee Size A Weight(Ibs) Extension Piece Figure 1105 Figure 1137 (NPS) (in) black galv. 1/8 11/16 .09 .10 1/4 13/16 .15 .16 3/8 15/16 .23 .24 - 1/2 1-1/8 .36 .37 (ig II -14 1-5/16 .56 .58 11-1/2 .90 .92 1-1/4 1-3/4 1.31 1.35 f- -A--,-I .-< 1-1/2 1.15/16 1.73 1.79 2 2.1/4 2.52 2.80 2-1/2 2-11/16 4.90 5.02 3 3-1/16 7.12 7.25 3-1/2 3-7/16 9.00 9.40 Size A Weight(Ibs) At4 3-13/16 11.31 12.30 (NPS) (in) black galv. N T 5 4-1/2 19.42 19.51 3/8 1-5/16 .10' .10' I IA 6 5-1/8 25.50 29.9 1/2 1-5/8 .14 .16 -� I - 3/4 1-15/16 .26 .26 1 2-1/16 .42 .41 I A 'POA l r j R 94 J supply.corn Lakeside Supply Company I. Pipe Fittings ',4 i as ...3-•cu,4 al i ; I1av F ,, ...oftm4** (A- r- .. _. i - . ,,r .. i'±'At!lx,li 4 oer.„ iAISIY3; MALLEABLE IRON CLASS 150 (STANDARD) Reducing Tee Figure 1105R 4 Z-)-1 Y X Size X Y Z Weight(Ibs) Size X Y Z Weight(Ibs) Size X Y Z Weight(Ibs) (NPS) (in) (In) (In) black galv. (NPS) (in) (in) (in) black gale. (NPS) (in) (in) (In) black gale. 1/8 1/8 1/4 3/4 3/4 3/4 .12 .14 1/2 1 1-9/16 1-3/8 1-11/16 .87 .94 1 1-8/4 1-5/8 2 1.58 1.61 1/4 1/4 1/8 3/4 3/4 3/4 .13 .14 1-1/4 1-3/4 1-9/16 1-3/4 1.04 1.07 1-1/4 1-7/8 1-13/16 2-1/8 1.76 1.83 3/8 5/16 15/16 7/8 .19 .20 3/4 1-7/16 1-5/16 1-5/8 .86 .86 2 1-1/21-1/2 2 1-15/16 2-3/16 1.95 1.95 1/4 7/8 13/16 15/16 .19 .20 3/4 1 1-9/16 1-7/16 1-11/16 .96 .88 2 2-1/4 2-3/16 2-1/4 2.24 2.39 1/4 3/8 15/16 15/16 15/16 .21 .22 1-1/4 1-3/4 1-5/8 1-3/4 1.09 1.10 1/2 1-1/2 1-1/2 1-7/8 1.65 1.70 3/8 1/2 1.1/8 1 1-1/8 .29 .29 1/2 1-3/8 1-1/4 1-9/16 .76 .79 3/4 1-5/8 1-5/8 2 1.87 1.90 3/8 1/4 7/8 7/8 15/16 .21 .22 1 3/4 1-7/16 1-3/8 1-5/8 .87 .92 1 1-3/4 1-3/4 2 1.79 2.00 1/2 1-1/16 1-1/16 1-1/16 .26 .29 1-1/4 1 1-9/16 1-1/2 1-11/16 1.11 1.13 2 1-1/4 1-7/8 1-7/8 2-1/8 2.35 2.55 1/4 1/2 1-1/8 15/16 1-1/8 .30 .31 1-1/4 1-3/4 1-11/16 1-3/4 1.13 1.19 1-1/2 2 2 2-3/16 2.55 2.65 3/8 3/8 1-1/16 1 1-1/16 .28 .29 3/8 1-1/4 1-1/4 1-7/16 .86 .89 2-1/2 2-5/8 2-5/8 2-3/8 3.50 3.59 1/2 1/4 1 1 1 .27 .29 1/2 1-3/8 1-3/8 1-9/16 .98 .98 2 2-3/8 2-3/16 2-5/8 3.43 3.51 1/2 1-1/16 1-1/16 1-1/16 .30 .32 1-1/4 3/4 1-7/16 1-7/16 1-5/8 1.06 1.10 1-1/2 2-1/2 2-11/16 2-1/2 2-11/16 3.80 3.80 3/4 1-1/4 1-1/4 1-3/16 .43 .45 1 1-9/16 1-9/16 1-11/16 1.18 1.22 2 2 2-3/8 2-1/4 2-5/8 3.28 3.32 1 1-3/8 1-3/8 1.1/4 .55 .57 1-1/2 1-7/8 1-7/8 1-13/16 1.45 1.40 2-1/2 2-11/16 2-5/8 2-11/16 3.65 4.10 1/4 3/4 1-5/16 1-1/8 1-5/16 .45 .46 2 2-1/8 2-1/8 1-7/8 1.70 1.82 3/4 1-3/4 1-3/4 2-5/16 2.82 2.80 3/8 1-1/8 15/16 1-1/8 .36 - 1/2 1-1/2 1-15/16 1-11/16 1-15/16 1.35 1.42 2-1/2 1 1-7/8 1-7/8 2-3/8 2.85 3.00 3/8 3/4 1-5/16 1-1/8 1-5/16 .46 .48 1-1/2 1-15/16 1-3/4 1-15/16 1.41 1.56 1-1/4 2-1/16 2-1/16 2-7/16 3.34 3.47 1/2 1/2 1-3/16 1.1/8 1-1/4 .43 .47 3/4 _ 3/4 1-1/2 1-5/16 1-3/4 1.00 1.03 2-1/2 1-1/2 2-3/16 2-3/16 2-1/2 3.46 3.57 3/4 3/4 1-5/16 1-1/4 1-5/16 .51 .51 1-1/2 1-15/16 1-13/16 1-15/16 1.50 1.54 2 2-3/8 2-3/8 2-5/8 3.65 3.75 1/4 1-1/16 1-1/16 1-1/8 .38 .40 1 1-1/4 1-13/16 1-11/16 1-7/8 1.30 1.44 3 3 3 2-13/16 5.82 6.00 3/8 1.1/8 1-1/8 1-1/8 .42 .46 1 1-5/8 1-1/2 1-13/16 1.15 1.18 2 2-1/2 2-1/4 2-7/8 4.10 4.30 3/4 1/2 1-3/16 1-3/16 1-1/4 .46 .49 1/2 1-7/16 1-3/8 1-11/16 1.03 1.10 2 3 3-1/8 2-7/8 3-1/8 6.07 6.53 1 1-7/16 1-7/16 1-3/8 .62 .66 3/4 1-1/2 1-7/16 1-3/4 1.08 1.10 2 2-1/2 2-3/8 2-7/8 4.80 4.85 1-1/4 1-5/8 1-5/8 1-7/16 .90 .93 1-1l2 1-1/4 1 1-5/8 1-9/18 1-13/16 1.26 1.27 2-1/2 2-1/2 2-13/16 2-11/16 3 5.80 5.91 1/4 1 1-1/2 1-5/16 1-1/2 .69 .71 1-1/4 1-13/16 1-3/4 1-7/8 1.52 1.42 3 3/4 1-7/8 1-7/8 2-5/8 4.02 4.22 1/2 1-1/4 1.1/8 1-3/8 .55 .55 1-1/2 1-15/16 1-7/8 1-15/16 1.50 1.55 1 2 2 2-5/8 4.15 4.36 1/2 3/4 1-3/8 1-1/4 1-7/16 .56 .62 1/2 1-7/16 1-7/16,1-11/16 1.19 1.25 3 1-1/4 2-3/16 2-3/16 2-3/4 4.68 4.67 1 1-1/2 1-3/8 1-1/2 .76 .73 3/4 1-1/2 1-1/2 1-3/4 1.29 1.40 1-1/2 2-5/16 2-5/16 2-13/16 5.11 5.26 1/2 1-1/4 1-3/16 1-3/8 .59 .62 1-1/2 1 1-5/8 1-5/8 1-13/16 1.44 1.49 2 2-1/2 2-1/2 2-7/8 5.79 5.81 3/4 3/4 1-3/8 1-5/16 1-7/16 .73 .75 1-1/4 1-13/16 1-13/16 1-7/8 1.45 1.47 2-1/2 2-13/16 2-13/16 3 6.09 6.22 1 1 1-1/2 1-7/16 1-1/2 .78 .81 2 2-3/16 2-3/16 2 1.86 2.01 3 4 3-13/16 3-5/8 3-13/16 11.80 11.00 1/4 1-1/8 1-1/8 1-1/4 .55 .55 1/2 2 2-1/4 1-7/8 2-1/4 2.14 2.25 _2 2-3/4 2-3/4 3-7/16 8.39 8.80 3/8 1-3/16 1-3/16 1-1/4 .60 .63 3/4 2 2-1/4 1-15/16 2-1/4 2.00 1.97 4 4 2-1/2 3-1/16 3-1/16 3-1/2 9.80 9.25 1/2 1-1/4 1-1/4 1-3/8 .70 .74 2 1 2 2-1/4 2 2-1/4 2.14 2.28 3 3-5/16 3-5/16 3-5/8 11.02 11.30 1 3/4 1-3/8 1-3/8 1-7/16 .82 .84 1-1/4 1-7/8 1-3/4 2-1/8 1.72 1.79 1-1/4 1-11/16 1.11/16 1-9/16 .92 .97 1-1/4 1-1/2 2 1-7/8 2-3/16 1.85 2.00 1-1/2 1-13/16 1-13/16 1-5/8 1.19 1.24 2 2-1/4 2-1/8 2-1/4 2.20 2.25 2 2 2 1-3/4 1.63 1.63 www,lakesidesupply.com 95 Lakeside Supply Company Pipe Fittings 216-941-6800 ; ( JA1! !!= MALLEABLE IRON FITTING (CLASS 150 STANDARD) Couplings Size M Weight(Ibs) Return Bends Center to Weight(Ibs) Figure 1125 (NPS) (in) black galv. open Pattern, Size Center 1/4 1/8 1 .07 .08 R.H.Flg:1119 (NPS) (in) black galv. 1/8 .11 .13 1/2 1-1/2 .36 - 3/8 1-1/8 1/4 .11 .12 3/4 2 .64 - 1/8 .14 .15 " 1 2-1/2 1.10 1.15 1/2 1/4 1-1/4 .15 .16 .. 1-1/4 3 1.77 - 3/8 .16 .18 u 1-1/2 3-1/2 2.55 - 1/8 .24 .25 2 4 4.00 4.25 3/4 3✓8 1-7/16 .25 .26 1/2 .26 .28 1/4 .35 .37 2 1-11/16 .39 .46 135 3/4 .42 .44 1/2 .60 .63 1-1/4 3/4 2-1/16 .64 .65 1 .68 .70 Cap Size Weight(Ibs) 1/2 .77 .80 Figure 1124 (NPS) black galv. 1-1/2 3/4 2-5/16 .90 .90 •1/8 .03 .04 1 •1/4 .06 .06 1-1/4 .90 .93 •3/8 .09 10. �_ 1/2 1.15 1.20 1/2 .12 .12 I�) M 314 1.34 1.34 _.. 3/4 .38 .38 2 1 2-13/16 1.401.40 1 .38 .38 1-1/4 1.53 1.53 1-1/4 .58 .61 1-1/2 1.55 1.57 1-1/2 .73 .75 1 2.12 2.20 2 1.13 1.20 1-1/4 2.09 2.14 2-1/2 3-1/4 2-1/2 1.75 1.80 1-1/2 2.09 2.11 3 2.59 2.75 2 2.50 2.56 3-1/2 3.16 3.24 1 3.16 3.24 4 4.54 4.61 1-1/4 3.22 3.05 5 6.44 6.89 3 1-1/2 3-11/16 3.30 3.47 6 10.00 9.98 2 3.23 3.38 2-1/2 3.31 3.40 •1/8,1/4,3/8 Made In Steel 2 4.32 4.40 3-1/2 2-1/2 4 4.72 4.80 3 4.99 5.15 1-1/2 4.90 5.00 Hex Locknut Minimum Dimensions Weight(Ibs) 2 5.10 5.00 Figure 1134 Size A B C D 4 2-1/2 4-3/8 5.93 5.95 (NPS) (in) (in) (in) (in) black galv. 3 6.55 6.62 -,a •1/8 .690 .500 .190 .040 .04 .04 3-1/2 6.30 6.45 /NN M\ 3 •1/4 .840 .660 .250 .060 .02 .03 Xtmil X 5 4 4-9/16 9.57 9.20 ` yyy x> 3/8 1.000 .770 .280 .060 .04 .04 6 4 4-13/16 10.30 10.70 ay 1/2 1.180 .970 .310 .060 .06 .06 N 3/4 1.430 1230 .340 .060 .12 .13 D(min) 1 1.750 1.500 .380 .060 .14 .16 C min Bdia.(min) 1 i 1-1/4 2.100 1.660 .420 .060 21 .19 1-1/2 2.350 2.120 .470 .060 .24 .25 Lakeside carries all \ + 2 2.880 2.630 .530 .090 .40 .47 NPSL Thread •1/8 81/4 Made In Steel malleable fittings in both black and galvanized finish. For nominal sizes larger than 2"see cast iron standard. 96 www.lakesidesupply.corn Lakeside Supply Company r Pipe Fittings 210-941-6800 LT . _..or f.__- "' JAJ !YJI= MALLEABLE IRON CLASS 150 (STANDARD) Street or Service Tee Size A J Weight(Ibs) Cross Size A Weight(Ibs) Straight:Figure 1106 (NPS) (in) (In) black gale. Fig:1107 (NPS) (in) black galv. Reducing:Figure 1106R 1/4 1-3/16 1-3/16 .15 .16 1/8 11/16 .12 .13 = 3/8 1-5/16 1-7/16 .24 .26 - 1/4 13/16 .18 .19 1/2 1-1/8 1-5/8 .34 .34 ,~i 3/8 15/16 .27 .27 3/4 1.5/16 1-7/8 .54 .63 1/2 1-1/8 .41 .43 1 1-1/2 2-1/8 .96 .99 i 3/4 1-5/16 .69 .68 1-1/4 1-3/4 2 7/16 1.38 1.49 (i. 1 1-1/2 1.12 1.14 1-1/2 1-15/16 2-11/16 1.93 2.00 1-1/4 1-3/4 1.44 1.56 2 2-1/4 3-1/4 3.16 3.20 1-1/2 1-15/16 1.98 2.05 Size run outlet 2 2-1/4 3.30 3.29 r Ay( (NPS) Wt. 2-1/2 2-11/16 5.90 5.75 N female run x A J A (Ibs) L--A-±-A 3 3-1/16 7.93 8.10 male run x (in) (in) (in) black A outlet MM."-7 4 3-13/16 13.50 13.91 i 1 1-1/4 1 x 1-1/4 1-3/4 2-5/16 1-3/4 1.32 A i I-f- 1 1 A J 45'Y-branch Coupling or Lateral Right Hand Size W Weight(Ibs) (NPS) (in) black galv. Figure 1108 Figure 1121 Size T U V Weight(Ibs) 1/8 15/16 .06 .06 (NPS) (in) (in) (in) black galv. 1/4 1-1/16 .09 .09 ax 3/8 1/2 1-7/16 1.15/16 .27 .29 3/8 1-3/16 .13 .13 f"'r 1/2 5/8 1-11/16 2-5/16 .37 .39 Wit' r. 1/2 1-5/16 .29 .31 3/4 3/4 2-1/16 2-13/16 .62 .65 t 3/4 1-1/2 .29 .31 iii:t, 1 7/8 2-7/16 3-5/16 .86 .93 1 1-11/16 .48 .49 1-1/4 1 2-15/16 3-15/16 1.63 1.62 1-1/4 1-15/16 .74 .76 1-1/2 1-1/8 3-1/4 4-3/8 2.00 2.06 1-1/2 2-1/8 1.00 1.00 2 1-1/4 3-15/16 5-3/16 3.05 3.26 i i 2 2-1/2 1.45 1.55 2-1/2 1-1/2 4-3/4 6-1/4 5.86 6.06 W i 2-1/2 2-7/8 2.40 2.45 ��� 1 3 1-11/16 5-9/16 7-1/4 9.30 9.40 i 1 1 3 3-3/16 3.30 3.39 4 2 7 9 15.70 15.85 4 3-11/16 5.65 5.73 / YV /`\ {T l ALL ELBOWS&TEES 3/8"AND LARGER ARE 100%GAS TESTED AT A �;10�� MINIMUM OF 100 PSI. Floor Flange Size Dia.of Diameter No.of Dia.of Holes Weight(Ibs) Figure 1190 (NPS) Flange(in) of Bolt Circle(in) Holes (in) black garv. 1/46 2-3/16 1-7/8 4 1/4 .27 .43 3/86 3 2 4 1/4 .33 .48 1/2 3-1/2 2-1/2 4 1/4 .56 .60 3/4 3-1/2 2-1/2 4 1/4 .60 .58 1 4 3 4 1/4 .85 .88 1-1/4 4 3 4 1/4 .90 .90 1-1/2 4-1/2 3-1/2 4 5/16 1.20 1.25 2 5-1/2 4-1/4 4 5/16 2.03 2.05 6Cast Iron t <,1 ' 3 '. ,Eakesidesupply.com 97 Pipe Fittings Lakeside Supply Company 11511*1 2 10-94 1-6800 ... . . Aftinfl.k-: MALLEABLE IRON FITTINGS CLASS 300 (XS/XH) 90°Elbow Straight 90'Street Elbow Size A Weight(Ibs) Size A J Weight fibs) Figure 1161 Figure 1170 (NPS) (in) black galv. (NPS) (in) (in) black galv. 1/4 15/16 .20 .20 1/4 15/16 1-7/16 .17 .18 r.... - 3/8 1-1/16 .29 .32 3/8 1-1/16 1-5/8 .26 .27 . li4s, 1/2 1-1/4 .47 .48 1/2 1-1/4 2 .40 .42 3/4 1-7/16 .66 .68 3/4 1-7/16 2-3/16 .68 .71 1 1-5/8 1.16 1 19 • L jkk 1 1-5/8 2-9/16 1.06 1.10 1-1/4 1-15/16 1.88 1.93 1-1/4 1-15/16 2-7/8 1.60 1.61 " + 1-1/2 2-1/8 2.46 2.57 1-1/2 2-1/8 3-1/8 2.20 2.25 I-4--A-,-1. 2 2-1/2 4.17 4.27 1-.-A-.. 2 2-1/2 3-11/16 3.56 3.75 2-1/2 2-15/16 5.30 5.93 3 3-3/8 5-1/8 9.55' 9.88* 3 3-3/8 9.65 9.75 7 *P0A 4 4-1/2 16.00 16.25 J A 45"Elbow Figure 1162 Size C Weight(lbS) (NPS) (in) black galv. 90°Reducing Elbow Size A B Weight(lbs) 1/4 13/16 .19 .20 Figure 1161R (NPS) (in) (in) black galv. 3/8 x 1/4 1 1 .26* - 3/8 7/8 .28 .29 I.--B-'1 1/2 x 3/8 1-3/16 1-3/16 .41* - - 1/2 1 .43 .44 3/4 x 1/2 1-5/16 1-3/8 .621 .67* 3/4 1-1/8 .66 .68 1 x 1/2 1-7/16 1-1/2 .87 .89 1 1-5/16 1.00 1.01 1 x 3/4 1-1/2 1-9/16 1.00 - 1-1/4 1-1/2 1.67 1.70 r\c, 1-1/2 1-11/16 2.15 2.28 A 1-1/4 x 1 1-3/4 1-13/16 1.60* - s 2 2 3.40 3.50 , 2-1/2 I 3 2-1/4 2-1/2 5.51 8.10 5.59 8.50 1-1/2 x 1-1/4 2 2-1/16 2.15 - 2 x 1-1/4 , 2-1/8 2-5/16 3.12 - jJ T4 2-13/16 13.41 13.79 2 x 1-1/2 2-1/4 2-3/8 3.30 3.30 *P0A Cross Figure 1165 45°Street Elbow Figure 1160 i 1 ' Center to Size End Wei•ht fibs) 4 (NPS) A(in) black galv. Size C K Weight • 1/4 15/16 .36* (NPS) (In) (in) black(lbs) 3/8 1-1/16 .46* - . , ..-.- Ira 1/2 1 1-3/8 .36 3/4 1-7/16 1.25 1.32 4 3/4 1-1/8 1-9/16 .54 i 1 1-5/8 1.90 - 1 1-5/16 1-13/16 .85 -A-0-1-.--Al 1-1/4 1-15/16 3.23* 3.28* 1-1/4 1-1/2 2-1/8 1.52 I t 1-1/2 2-1/8 4.20* 6.40* 4.35* 1-1/2 1-11/16 2-5/16 2.06 A 2 2-1/2 6.60* 2 2 2-11/16 3.34 A c , ...... _ , 98 www.lakesidesuppiy.com Lakeside Supply Company Pipe Fittings 216-941-6 00 pan, `�•. l" m __ a.Rt i�'A` ..lT,� _ 1�Ni�r'��...,. _ Pr_(�a ..) .," ,.�" Ri4'�....i.. - j,r (IL" ANVIL .........a.,, ,.. MALLEABLE IRON FITTINGS-CLASS 300 Reducing Tee Center to End Weight(Ibs) Reducer End to Figure 1164R Size A B C Figure 1167 Size End Weight(Ibs) (NPS) (in) (in) (in) black galv. (NPS) M(in) black galv. 3/8 3/6 1/4 1 1 1 .37 - 3/8 1/4 1-7/16 .21 .22 1/4 1-1/16 1-1/16 1-1/8 .48' .52 1/4 1-11/16 .31 .31 1/2 1/2 3/8 1-3/16 1-3/16 1-3/16 .61' - 1/2 3/8 1-11/16 .34 .36 3/4 1-3/8 1-3/8 1-5/16 .80 - 1/4 1-3/4 .46' .49' 1/2 3/4 1-7/16 1-3/8 1-7/16 .93 - 3/4 3/8 1-3/4 .47' .48' 1/2 1-5/16 1-1/4 1-3/8 .78 - 1/2 1-3/4 .50 .52 3/4 1/4 1-3/16 1-3/16 1-1/4 .76' .80 1/4 2 .66 .68 1, -MOW," 3/4 3/8 1-1/4 1-1/4 1-5/16 .80 - = ..;- 3/8 2 .71 .73 'a""`'a' 1/2 1-5/16 1-5/16 1-3/8 .90 .88 t.#u 1 1/2 2 .71 .75 1/2 1 1-5l8 1-1l2 1-5/8 1.36 - `•le* : 3/4 2 .79 .82 3/4 3/4 1-1/2 1-7/16 1.9/16 1.27 - 1/2 2-3/8 1.12' 1.14' 1 1-5/8 1-9/16 1-5/8 1.38 - 1-1/4 3/4 2-3/8 1.16` 1.22' 11/4 1-1/4 1-1/4 1-3/8 1.09 - 1 2-3/8 1.29 1.25 1 1/2 1-7/16 1-7/16 1-1/2 1.26 1.29 TT I 1/2 2-11/16 1.51 1.54 3/4 1-1/2 1-1/2 1-9/16 1.33 1.43 7 3/4 2-11/16 1.57 1.60 I`A'i-6-1 1 1 1-3/4 1-5/8 1-13/16 1.92 - I 1-1/2 1 2-11/16 1.62 1.70 1/2 1-1/2 1-1/2 1-11/16 1.70 1.88 M IMF 1-1/4 2-11/16 1.61 1.86 C IN: 1-1/4 1-1/4 3/4 1-5/8 1-5/8 1-3/4 1.90 1.99 1/2 3-3/16 2.39` - a 1 1-3/4 1-3/4 1.13/16 2.10 2.13 3/4 3-3/16 2.44 2.50 1/2 1-5/8 1-5/8 1-13/16 2.27 2.32 2 1 3-3/16 2.53 2.58 1-1/2 1-1/2 3/4 1-11/16 1-11/16 1.7/8 2.46 2.47 1-1/4 3-3/16 2.66 2.72 1 1-13/16 1-13/16 2 2.60 2.70 1-1/2 3-3/16 2.72 2.88 1-1/4 2 2 2-1/16 3.05* 3.12* 2-1/2 1-1/2 3-11/16 4.09 4.30 1-1/2 2 2-1/2 2-3/8 2-1/2 4.50 - 2 3-11/16 4.32 4.54 1/2 1-3/4 1-3/4 2-1/16 3.35 3.54 1-1/2 4-1/16 5.79' 5.87' 2 3/4 1-13/16 1-13/16 2-1/8 3.56 3.60 3 2 4-1/16 5.75 5.50 2 1 2 2 2-1/4 3.97 4.00 2-1/2 4-1/16 6.45 6.60 1-1/4 2-1/8 2-1/8 2-5/16 4.21 4.40 4 2 4-3/8 9.50 9.60 1-1/2 2-1/4 2-1/4 2-3/8 4.60 4.70 3 4-3/8 10.00 10.60 2-1/2 2-1/2 1-1/2 2-7/16 2-7/16 2-5/8 6.35' 6.60' 'POA 2 2-11/16 2-11/16 2-3/4 7.59' 7.50' Coupling End to 3 3 2 2-13/16 2-13/16 3-1/8 9.60 10.10 Figure 1166 Size End Weight(Ibs) POA (NPS) W(NPS) black galv. 1/4 1-3/8 .17 .18 ' 3 3/8 1-5/8 .26 .27 1/2 1-7/6 .42 .43 `? t' 3/4 2-1/8 .65 .68 Straight Tee Center 1 2-3/6 .99 1.03 Figure 1164 Size to End Weight(Ibs) 1-1/4 2-7/8 1.64 1.67 (NPS) A(in) black galv. 1-1/2 2-7/8 2.04 6 2.08 s+6mew 1/4 1-5/16 .27 .30 6 W 2 3-5/8 3.24 3.30 m'4'6 3/8 1-1/16 6 .42 .43 2-1/2 4-1/8 5.45 5.65 Ak 1/2 1-1/4 .65 .69 3 4-1/6 7.30 7.40 3/4 1-7/16 1.07 1.10 Cap Size Height Weight(Ibs) ,6. 666 1 1-5/8 1.63 6 1.65 Figure 1163 (NPS) L(in) black gale. 1-1/4 1-15/16 2.53 2.59 1/4 25/32 .10 .11 1-1/2 2-1/8 3.40 3.49 3/8 13/16 .15 .15 2 2-1/2 5.20 5.40 7 1/2 1 .23 .24 I� A-- �A- I 2-1/2 2-15/16 7.98 8.04 too 3/4 13116 .15 .36 15 3 3-3/8 12.56 12.75 3000 1 1-1/4 .58 .58 __ ___ ___ __ 4 4-1/2 23.86 24.05 Ii 1-1/4 1-3/8 .94 .95 A 1-1/2 1-7/16 1.18 1.32 2 1-11/16 1.94 1.96 + FT_ 2-1/2 2-1/16 3.32 3.35 3 2-3/16 4.71 4.80 P. * 16.1'"M /`_. . 1* 1 "6.x. 161x:6"46 - .6f"fi i, --'rrrurr,,. .)/.- . ,::t' *Iv .It..,L:(" l t www.lakesidesupply.corn 99 Pipe Fittings Lakeside Supply Company 216-941-0800 '('.r 111 w!L MALLEABLE IRON UNIONS-CLASS 150; 250; 300 Copper to Iron Class 300 90"Elbow Co per or Copper Alloy to Iran pp Alloy Female Union P Copper or Co Unions Size End to Weight(Ibs) Figure 552 300 lb.wsp Size Ctr.to End(in) Wt.(lbs) (NPS) End(in) black gale. (NPS) Elbow Union black Class 150 Union 1/8 1-5/16 .15 .15 .: ,,;, 3/8 1-1/16 2-1/16 .51 Figure 463 1/2 1-1/4 2-5/16 .79 150 lb.wsp t1/4 1-13116 .46 .47 3/4 1-7/16 2-3/4 1.24 3D0 lb.wog t3/8 1-13/16 .42 .43 non-shock t1/2 1-15/16 .44 .45 l 1 1-5/8 3 1.68 tUL Listed t3/4 2-1/15 .60 .63 - `'''r ® "- t3/4 x 1/2 2-1/16 55 .59 - t1 2-7/16 .91 .94 t1-1/4 2.5/8 1.45 1.45 t1-1/2 2-3/4 1.69 1.72 y, t2 2-15/16 2.46 2.44 2-1/2 3-5/8 3.60 3.70 3 3-3/4 4.95 4.98 Class 250 Union 1/8 1-5/16 .14 .14 Figure 554 t1/4 1.13/16 .46 .47 250 lb.wsp All Iron Union 500 lb.wog t3/8 1-13/16 .42 .43 End to non-shock 1-1/2 2-1/16 .53 .54 Class3-3 Size End tUL ListedWeight(Ibs) Figure J3 t3/4 2-1/4 .80 .82 (NPS) (in) black galv. t1 2-9/6 1.28 1.30 1/8 1-1/2 .18 .19 t1.1/4 2-3/4 1.63 1.65 1. 1/4 1-5/8 .28 .29 t1.1/2 3 2.06 2.10 3/8 1-13/16 .36 .37 yr; t2 3-3/8 3.48 3.49 -1- 1/2 2-18 .56 .57 xs 2-1/2 3-7l8 5.30 5.38 $.. 3/4 2-7/16 .84 .87 3 4-1/4 7.60 7.76 1 2-3/4 1.27 1.31 4 4-7/8 17.50 17.86 1-1/4 3 2.04 2.10 Class 300 Union 1/8 1-5/16 .14 .14 1-1/2 3-3/16 2.74 2.82 Figure 459 1/4 1-13/16 .47 .48 2 3-1/2 4.16 4.28 300 lb.wsp 3/8 1-13/16 .43 .44 2-1/2 3-11/16 6.00 6.18 600 lb.wog non-shock 1/2 2-1/16 .53 .55 3 3-15/16 7.60 7.83 _ 3/4 2-1/4 .80 .82 �. 1 2-9/16 1.27 1.30 1-1/4 2-3/4 1.63 1.72 s 1-1/2 3 2.13 2.20 2 3-8/8 3.46 3.47 2-1/2 3-7/8 5.05 5.45 3 4-1/4 7.66 7.73 Dart Union 4 4-7/8 17.70 17.83 Bronze to Bronze Seat Class 300 Union Union Figure 551 1/2 3 .62 - Figure Size A B C D Weight(Ibs) 300 lb.wsp g (NPS) (in) (in) (in) (in) black galv. 600 lb.wog 3/8 1-3/4 15/16 1-1/2 1-3/4 0.41 0.43 non shock 3/4 3-3/16 .92 - _ 1/2 2-1/8 1-1/8 1-3/16 2 0.58 0.61 ,'= I� 3/4 2-5/16 1-3/8 2-3/16 2-1/2 0.82 0.86 �4s 1 2-5/8 1-11/16 2-9/16 3 1.31 1.37 1 3-5/8 1.54 - L = A ��1 1-1/4 2 13/16 2-1/16 3-1/16 3-1/2 1.91 2.03 ,,,,[. � � 1 1-1/2 3 2-3/16 3-3/8 4 2.32 2.44 ta 1-1/2 4-1/2 2.60 2.73 2 3-5/8 2-7/8 4-1/16 4-5/8 4.00 4.20 Oon C on FI � Flet •• 2 4-5/8 2.41 - 100 . +. a ply o Lakeside Supply Company r Pipe Fittings 210,-941-0800 " L. i moo 1 tir° i1 '(4,19,,), 'V' , .„„ „ , , -.-11.Y: 0,, , . --- , „/ \kilM . ..EEE .... (10ANS1111-: CAST IRON THREADED FITTINGS CLASS 125, (STANDARD) 90°Elbow Straight 22-1/2°Elbow Size A B Weight(Ibs) Figure 351 Figure 356A (NPS) (in) (in) black galv. 1/4 1/2 13/16 .16 .17 •- 3/6 9/16 15/16 .25 .26 .e' -).... Size A B Weight(Ibs) . .' 0°illit' 1/2 11/16 1-1/8 .40 .41 (NPS) (in) (in) black galv. 3/4 13/16 1-5/16 .60 .61 . 3/4 3/8 7/8 .52 • . 1 15/16 1-1/2 .92 .95 1 7/16 1 .80 • 1-1/4 1-1/8 1-3/4 1.44 1.46 1-1/4 1/2 1-1/8 1.40 • ..,4 1-1/2 1-5/16 1-15/16 1.95 2.00 1-1/2 5/8 1-1/4 1.64 • 2 1-9/16 2-1/4 3.13 3.21 84 : 2 3/4 1-7/16 2.50 •i 'r•-A-0-1 I 2-1/2 1-13/16 2-11/16 4.94 5.13 J4 2-1/2 3/4 1-5/8 3.95 • 3 2-3/16 3-1/8 7.21 7.40 * 4 2-11/16 3-13/16 12.17 12.67 A Not stocked Bl- 1 - 5 3-5/16 4-1/2 21.46 - 6 3-7/8 5-1/8 31.33 33.33 _i 8 5-3/16 6-9/16 64.56 67.14 45°Elbow Size A B Weigpt(lbs) Figure 356 (NPS) (in) (in) black galv. 1/4 7/16 3/4 .16 .17 90'Elbow ., Flanged and Threaded A k:',4 3/8 7/16 13/16 .23 - Figure 371 1/2 7/16 7/8 .37 .38 gir 3/4 1/2 1 .55 .56 1* 9/16 1-1/8 .83 .88 (NBPSe) (in) Wbellagchkt ) i Size (in)A B (lbS 2-1/2 1-13/16 2-11/16 10.22 01\ 1-1/4 5/9 1-1/4 1.33 1.36 1-1/2 13/16 1-7/16 1.79 1.83 2 1 1-11/16 2.89 2.96 "It 4 3 2-3/16 3-1/8 13.25 it / 2-1/2 1-1/16 1-15/16 4.29 4.35 4 2-11/16 3-13/16 21.56 3 1-3/16 2-3/16 6.44 6.56 5 3-5/16 4-1/2 28.13 6 3-7/8 5-1/8 40 50 BA 3-1/2 1-3/8 2-3/8 8.42 - 4 1-9/16 2-5/8 10.64 11.22 41 8 5-3/16 6-9/16 80.06 14- 5 1-7/8 3-1/16 16.96 17.38 *Nominal Pipe Sizes of 4"and larger have two holes tapped ' 6 2-3/16 3-7/16 26.02 26.19 for stud or tap bolts. i 9 2-7/8 4-1/4 50.17 52.00 f *1 NPS size available In 1 NPS x 1/2 NPS reducing size, r black or galvanized. 45'Elbow Flanged and Threaded Figure 372 Cast Iron Threaded Fittings Pressure-Temperature Ratings Size A B Weight(Ibs) Pressure,(psig) (NPS) (in) (in) black Temp.(°F) Class 125 ' Class 250 4 1-9/16 2-5/8 19.88 -20°M 150° 175 400 6 2-3/16 3-7/16 35.31 200° 165 370 law, 8 2-7/8 4-1/4 64.41 250° 150 340 300° 140 310 350° 125 300 400° 250 A B +-C . i'"'-"c-'-..t F. !F ' -.0 Oi.'' 1 '' A Ai a-AS , At ,„„.., iitelli-'oi,,'i - _ ".. ,,',:t\,z• • - * - '10,0. -1- -1'. -"'.'° witm,haketkidesit!.. , ACOM 10 1 Pipe Fittings Lakeside Supply Company d 1. 216-941-6800 r ,A L CAST IRON THREADED FITTINGS CLASS 125, (STANDARD) 90°Reducing Size A B C D Weight Elbow-Figure 352 abs) ) (NPS) (in) (in) (in) (in) black 1/2 1/4 5/8 3/4 1-1/16 1-1/16 .40 1/2 3/8 5/8 11/16 1-1/16 1-1/16 .34 3/4 1/2 11/16 13/16 1-3/16 1-1/4 .51 1 1/2 11/16 15/16 1-1/4 1-3/8 .67 1 3/4 13/16 15/16 1-3/8 1-7/16 .76 1-1/4 1/2 11/16 1-1/16 1-5/16 1-1/2 1.07 1-1/4 3/4 13/16 1-1/8 1-7/16 1-5/8 1.02 1-1/4 1 15/16 1-1/8 1-9/16 1-11/16 1.21 1-1/2 1/2 3/4 1-1/4 1-3/8 1-5/8 1.53 1-1/2 3/4 7/8 1-5/16 1-1/2 1-13/16 1.55 ........:� 1-1/2 1 1 1-1/4 1-5/8 1-13/16 1.44 1-1/2 1-1/4 1-3/16 1-1/4 1-13/16 1-7/8 1.74 4 2 1/2 1-3/16 1-7/18 1-1/2 1-3/8 2.22 lit 2 3/4 1-5/16 1-1/2 1-5/8 2 2.20 2 1 1-1/16 1-7/16 1-3/4 2 208 2 1-1/4 1-3/16 1-7/16 1-7/8 2-1/16 2.33 2 1-1/2 1-5/16 1-1/2 2 2-1/8 2.59 2-1/2 2 1-9/16 1-7/8 2-7/16 2-9/16 4.01 "-Cl-,- 2-1/2 1 1-3/16 1-3/4 1-15/16 2-5/16 2.93 13-.-1_ 2-1/2 1-1/4 1-3/16 1-3/4 2-1/16 2-3/8 3.41 2-1/2 1-1/2 1-5/16 1-13/16 2-3/16 2-7/16 3.68 '-f"?-- ---"�---""" 3 1-1/4 1-5/8 2-5/16 2-9/16 2.15/16 5.98 C p' 3 1-1/2 1-5/8 2-5/16 2-9/16 2-15/16 5.65 3 2 1-5/8 2-1/4 2-9/16 2-15/16 5.65 3 2-1/2 1-7/8 2-3/16 2-13/16 3-1/16 6.44 3-1/2 3 2-3/16 2-7/16 33/16 3-3/8 8.95 4 2 2-3/16 2-15/16 3-1/4 3-5/8 11.89 4 2-1/2 2-3/16 2-3/4 3-1/4 3-5/8 11.27 4 3 2-3/16 2-11/16 3-1/4 3-5/8 10.63 4 3-1/2 2-7/16 2-11/16 3-1/2 3-11/16 11.89 5 4 2-13/16 3-5/16 4 4-3/8 16.47 5 2-1/2 2-13/16 3-1/2 4 4-3/8 19.88 5 3 2-13/16 3-7/16 4 4-3/8 19.00 6 3 2-5/16 3-13/16 3-9/16 4-13/16 19.43 6 4 2-13/16 3-7/8 4-1/16 4-15/16 23.53 6 5 3-3/8 3-13/16 4-5/8 5 26.66 8 6 4-3/16 5-1/8 5-9/16 6-3/8 51.11 Straight Tee Size A B Weight(Ibs) Figure 356 (NPS) (in) (In) black galv. 1/4 1/2 13/16 .22 .23 3/8 5/8 1 .35 .36 1/2 11/16 1-1/B .56 .58 Jar# MI3/4 13/16 1-5/16 .84 .85 1 15/16 1-1/2 1.25 1.31 ---.. E - 1-1/4 1-1/8 1-3/4 2.03 2.07 1-1/2 1-5/16 1-15/16 2.70 2.72 2 1-9/16 2-1/4 4.23 4.33 h8-H.-8-1 2-1/2 1-13/16 2-11/16 6.67 6.79 3 2-3/16 3-1/8 10.00 10.16 3-1/2 2-7/16 3 /8 16.33 16.99 -- 4 2-11(1/16 3-3/4 16.33 16.99 5 3-5/16 4-1/2 27.33 27.67 6 3-7/8 5-1/8 40.85 41.40 8 5-3/16 6-9/16 79.00 81.25 102 www.lakesidesupply.com Lakeside Supply Company r 216-941-6800 Pipe Fittings 74fi:,�..L..iSi""1 i 1-''."t1 a 5frtaR" t xr 1..b; (:'z �� ! CAST IRON THREADED FITTINGS CLASS 125, (STANDARD) Reducing Tee Figure 359 4 D-�-0-E-1{ 4- - a- , Reducing Tee:Figure 359 Reducing Tee:Figure 359 Size(NPS) A B C D E F Wt.(Ibs) Size(NPS) A B C D E F Wt.(Ibs) s x t x u (in) (in) (in) (in) (in) (in) black galv. s x t x u (In) (in) (in) (in) (in) (in) black galv. 1/4 11/16 11/16 13/16 1-1/8 1-1/8 1-1/8 0.57 - 1/2 1-1/8 13/16 1-1/8 1-1/4 1-13/16 1-9/16 1-7/8 1.93 - 3/6 11/16 11/16 3/4 1-1/8 1-1/8 1-1/8 .057 - 1-1/2 15/16 1-1/4 15/16 1-15/16 1-11/16 1-15/16 2.14 - 1/2 1/2 3/4 1-1/2 15/16 1-1/4 15/16 1-15/16 1-3/4 1-15/16 2.18 - 3/4 13/16 13/16 11/16 1-1/4 1-1/4 13/16 0.68 - 1/2 13/16 3/4 1-1/4 1-7/16 15/16 1-11/16 1.75 - 1 1 1 13/16 1-7/16 1-7/16 1-3/8 1 - 3/4 7/8 13/16 1-1/4 1-1/2 1-3/8 1-3/4 1.7 - 1/4 3/4 13/16 15/16 13/16 15/16 1-1/4 15/16 0.79 - 1 1 1 15/16 1-1/4 1-5/8 1-1/2 1-13/16 1.72 - 1/2 11/16 11/16 13/16 13/16 1-1/8 1-1/4 0.64 - 1-1/8 13/16 1-1/8 1-1/4 1-13/16 1-11/16 1-7/8 2.08 - 1/2 1-1/2 15/16 1-1/4 15/16 1-15/16 1-13/16 1-15/16 2.29 - 3/4 13/16 13/16 13/16 15/16 1-1/4 15/16 0.75 - 2 1-1/2 1-7/16 15/16 2-1/8 2 2 2.91 3/4 1/4 9/16 9/16 7/8 11/16 11/16 13/16 0.62 - 1/2 13/16 11/16 1-1/4 1-7/16 15/16 1-11/16 1.67 1.73 3/4 3/8 11/16 11/16 15/16 13/16 13/16 1-1/4 0.75 - 1-1/2 3/4 7/8 13/16 1-1/4 1-1/2 1-7/16 1-3/4 1.79 - 1/2 11/16 11/16 13/16 13/16 13/16 1-1/4 0.76 - 1-1/8 1 1 15/16 1-1/4 1-5/8 1-9/16 1-13/16 1.97 2.05 1 15/16 15/16 13/16 1-7/16 1.7/16 1-3/8 0.99 - 1-1/8 13/16 1-1/81-1/4 1-13/16 1-3/4 1-7/8 2.28 - 1-1/2 15/16 1-1/4 15/16 1-15/16 1-7/8 1-15/16 2.5 - 1/4 1 15/16 15/16 15/16 1-1/2 1-1/4 1-1/2 1.08 - 2 1-1/2 1-7/16 15/16 2-1/8 2-1/16 2 3.07 - 1/2 11/16 3/4 15/16 1-1/4 13/16 1-3/8 0.9 - 1/2 13/16 13/16 1-1/4 1-7/16 1-7/16 1-11/16 1.84 - 1/2 3/4 13/16 13/16 15/16 1-3/8 1-1/4 1-7/16 0.91 - 3/4 7/8 7/8 1-1/4 1-1/2 1-1/2 1-3/4 1.95 - 1 15/16 15/16 15/16 1-1/2 1-3/8 1-1/2 1.08 - 1-1/2 1 1 1 1-1/4 1-5/8 1-5/8 1-13/16 2.13 2.17 1/2 11/16 11/16 15/16 1-1/4 13/16 1-38 0.89 - 1-1/813/16 13/16 1-1/4 1-13/16 1-13/16 1-7/8 2.44 - 3/4 3/4 13/16 13/16 15/16 1-3/8 15/16 1-7/16 1 2 1-1/2 1-1/2 15/16 2-1/8 2-1/8 2 3.23 - 1 - 2-1/2 1-13/16 1-1316, 15/16 2-7/16 2-7/16 2-3/16 4.15 - 1 15/16 15/16 15/16 1-1/2 1-7/16 1-1/2 1.13 - 1/2 1-1/2 15/16 1-3/8 1-1/2 2 1-13/16 2-1/8 2.95 - 1/4 11/16 11/16 1-1/8 1-1/8 1-1/4 1-38 1.01 - 2 1-9/16 1-7/16 1-9/16 2-1/4 1-7/8 2-1/4 3.3 - 1/2 11/16 11/16 15/16 1-1/4 1-1/4 1-3/8 1.01 1.03 1-1/8 13/16 1-1/8 1-7/16 1-7/8 1-3/4 2-1/16 2.5 - 1 3/4 13/16 13/16 15/16 1-3/8 1-3/8 1-7/16 1.11 - 3/4 1-1/2 15/16 15/16 1-1/2 2 1-13/16 2-1/8 3.4 - 2 1-9/16 1-7/16 1-9/16 2-1/4 1-15/16 2-1/4 3.31 - 1-1/8 1-1/8 1-1/8 15/16 1-11/16 1-11/16 1-9/16 1.49 - 1 11/16 11/16 1-7/16 1-3/4 1-5/8 2 2.7 - 1-1/2 1-1/4 1-1/4 1 1-13/16 1-13/16 1-5/8 1.84 - 1-1/8 13/16 1-1/8 1-1/2 1-7/8 1-3/4 2-1/16 2.94 - 1/2 13/16 13/16 1-1/8 1-7/16 15/16 1-5/8 1 - 1 1-1/2 15/16 1-1/4 1-1/2 2 1-13/16 2-1/8 2.85 - 1/2 1 15/16 15/16 1-1/8 1-9/16 1-3/8 1-11/16 1.38 - 2 1-9/16 1-7/16 1-9/16 2-1/4 2 2-1/4 3.46 - 2-1/2 1-7/8 1-13116 1-9/16 2-9/16 2-3/8 2-7/16 4.88 - 1-1/8 1-1/8 1-1/8 1-1/8 1-3/4 1-9/16 1-3/4 1.64 - 1/2 11/16 1 1-7/16 1-3/4 1-5/8 2 2.48 - 3/4 13/16 13/16 1-1/8 1-7/16 15/16 1-5/8 1.27 - , 3/4 7/8 7/8 1-7/16 1-9/16 1-1/2 1-15/16 2.5 - 3/4 1 15/16 15/16 1-1/8 1-9/16 1-7/16 1-11/16 1.43 - 1 11/16 1 1-7/16 1-3/4 1-5/8 2 2.73 - 1-1/8 1-1/8 1-1/8 1-1/8 1-3/4 1-5/8 1-3/4 1.73 - 1-18 1-1/8 13/16 1-1/8 1-7/16 1-7/8 1-3/4 2-1/16 2.9 - 1/2 11/16 11/16 1-1/8 15/16 1-1/4 1-9/16 1.27 1.31 1-1/2 15/16 1-1/4 1-1/2 2 1.718 2-1/8 3.13 - 2 2 1-9/16 1-7/16 1-9/16 2-1/4 2-1/16 2-1/4 3.71 - 3/4 13/16 13/16 1-1/8 1-7/16 1-3/8 1-5/8 1.36 - 2-1/2 1-7/8 1-3/4 1-9/16 2-9/16 2-3/8 2-7/16 4.54 - 1-1/8 1 1 15/16 15/16 1-1/8 1-9/16 1-9/16 1-11/16 1.53 1.56 1/2 13/16 13/16 1-7/16 1-1/2 1-7/16 1-7/82.34 2.38 1-1/8 1-1/8 1-1/8 1-1/8 1-3/4 1-11/16 1-3/4 1.79 - 3/4 7/8 7/8 1-7/16 1-9/16 1-1/2 1-15/16 2.46 - 1-1/2 1-1/4 1-1/4 13/16 1-7/8 1-13/16 1-13/16 2.07 - 1 11/16 1 1-7/16 1-3/4 1-5/8 2 2.66 - 2 1-7/16 1-7/16 13/16 2-1/16 2 1-7/8 2.66 - 1-1/2 1-1/8 13/16 13/16 1-7/16 1-7/8 1-13/16 2-1/16 2.98 - 1-1/2 15/16 15/16 1-1/2 2 1-15/16 2-1/8 3.24 - 1/2 11/16 11/16 1-1/8 15/16 15/16 1-9/16 1.47 - 2 1-9/16 1-1/2 1-9/16 2-1/4 2-1/8 2-1/4 3.7 3/4 13/16 13/16 1-1/8 1-7/16 1-7/16 1-5/8 1.57 - 2-1/2 1-7/8 1-15/16 1-9/16 2--9/16 2-9/16 2-7/16 5.46 1-1/8 1 15/16 15/16 1-1/8 1-9/16 1-9/16 1.11/16 1.73 - 1/2 13/16 13/16 1-7/16 1-1/2 1-1/2 1-7/8 2.74 2.81 1-1/2 1-1/4 1-1/4 13/16 1-7/8 1-7/8 1-13/16 2.29 - 3/4 7/8 7/8 1-7/16 1-9/16 1-9/16 1-15.16 2.86 - 2 1-7/16 1-7/16 13/16 2-1/16 2-1/16 1-7/8 2.81 - 1 11/16 11/16 1-7/16 1-3/4 1-3/4 2 3.05 3.14 2 1-1/8 13/16 13/16 1-7/16 1-7/8 1-7/8 2-1/16 3.38 1-1/2 15/16 15/16 1-1/2 2 2 2-1/8 3.59 3.74 2-1/2 1-7/8 1-7/8 1-9/16 2-9/16 2-9/16 2-7/16 5.17 5.38 4 3 3 2-7/16 3-11/16 3-11/16 3-1/2 16.07 - 1 ' ' �. M - I 11h. . ._iM�( 1 L `, W Wslakesi Sapp c 103 Pipe Fittings Lakeside Supply Company .7 ,.: 216-941-6800 v/4= CAST IRON THREADED FITTINGS CLASS 125, (STANDARD) Reducing Tee:Figure 359 Reducing Tee:Figure 359 Size(NPS) A 6 C D E F Wt. Ibs 1 Size(NPS) A B C D E F Wt.(Ibs) s x t x u (In) (in) (in) (in) (in) (in) black galv. s x t x u (in) (in) (in) (in) (in) (in) black galv. 1/22 1-9/16 1-11/16 1-7/8 2-7/16 2-1/8 2-9/16 5.29 - 1-1/8 3 2.3/16 2-1/2 2-3/8 3-3/16 3-1/8 3-3/8 12.54 - 2-1/2 1-13/16 1-13/16 1-13/16 2-11/16 2-1/4 2-11/16 5.2 - 2 3-1/2 2-7/16 2-7/16 2-7/16 3-7/16 3-5/16 3-7/16 12.93 - 3/4 2-1/2 1-13/16 1-3/4 1-13/16 2-11/16 2.1/4 2-11/16 5.1 - 2-1/2 1-15/16 1-15/16 2-3/8 2-7/8 2-13/16 3-5/16 10.69 - 1 2 1-9/16 1-9/16 1-7/8 2-7/16 2.1/8 2-9/16 5.03 - 3 2-3/16 2.1/16 2-3/8 3-3/16 3 3-5/16 11.77 - 2-1/2 1-13/16 1-3/4 1-13/16 2-11/16 2.5/16 2-11/16 5.36 - 2-1/2 3-1/2 2-7/16 2-3/8 2-7/16 3-7/16 3-5/16 3-7/16 12.56 - 1-1/2 15/16 15/16 1-13/16 2-3/16 1-15/16 2-7/16 4.28 - 4 2-11/16 2-5/8 2-1/2 3-11/16 3-11/16 3-1/2 15.27 - 1-1/8 2 1-9/16 1-1/2 1-7/8 2-7/16 2-1/8 2-9/16 4.96 - 1-1/2 1-3/8 1-3/8 2.7/16 2-3/8 2-5/16 3-1/16 8.33 - 2-1/2 1-13/16 1-3/4 1-13/16 2-11/16 2-3/8 2-11/16 5.4 - 2 1-5/8 1-9/16 2-706 2-5/8 2-9/16 3-3/16 8.66 - 1-1/2 15/16 15/16 1-13/16 2-3/16 1-15/16 2-7/16 4.23 - 2-1/2 1-15/16 1-7/8 2-3/8 2-7/8 2-13/16 3-5/18 10 - 1-1/2 2 1-9/16 1-1/2 1-7/8 2-7/16 2-1/8 2-9/16 4.85 - 3 3 2-3/16 2-1/8 2-3/8 3-3/16 3-1/8 3-3/8 11.33 - 2-1/2 1-13/16 1-13/16 1-13/16 2-11/16 2.7/16 2-11/16 5.82 - 3-1/2 3-1/2 2-7/16 2-3/8 2-7/16 3-7/16 3-7/16 3-7/16 13.95 - 1/2 3/4 13/16 1-3/4 1-11/16 1-1/2 2-3/16 3.57 - 4 2-11/16 2-11/16 2-1/2 3-11/16 3-11/16 3-1/2 15.23 - 2-1/2 3/4 7/8 7/8 1-3/4 1-3/4 1-9/16 2-1/4 3.62 - 5 3-5/16 3-5/16 2-9/16 4-5/16 4-5/16 3-3/4 20.28 - 1 1 11/16 1-3/4 1-15/16 1-3/4 2-5/16 3.92 - 1 11/16 11/16 2-3/8 2-1/8 2-1/8 2-15/16 8 - 2 1-1/8 13/16 13/16 1-3/4 2-1/16 1-7/8 2-3/8 4.26 - 1-1/8 1-1/4 1-1/4 2-3/8 2-1/4 2-1/4 3 8.63 - 1-1/2 1-3/8 1-3/8 2-7/16 2-3/6 2-3/8 3-1/16 8.87 - 1-1/2 15/16 15/16 1-13/16 2-3/16 2 2-7/16 4.42 - 2 1-9/16 1-9/16 1-7/8 2-7/16 2-1/4 2-9/16 5.17 - 3-1/2 2 1-5/6 1-5/8 2-7/16 2-5/8 2-5/8 3-3/16 9.94 - 2-1/2 1-15/16 1-15/16 2-3/8 2-7/8 2-7/8 3-5/16 10.95 - 2-1/2 1-13/16 1-7/8 1-13/16 2-11/16 2-9/16 2-11/16 6 - 3 2-3/16 2-3/16 2-3/8 3-3/16 3-3/16 3-3/8 12 1/2 3/4 3/4 1-3/4 1-11/16 1-11/16 2-3/16 4 - 4 2-11/16 2-11/16 2-1/2 3-11/16 3-11/16 3-1/2 14.25 - 3/4 7/8 7/8 1-3/4 1-3/4 1-3/4 2-1/4 4.29 - 5 3-5/16 3-5/16 2-9/16 4-5/16 4-5/16 3-3/4 19.66 - 1 1 1 1.3/4 1-15/16 1-15/16 2-5/16 4.48 - 3/4 4 2-3/4 3 2-3/4 3-3/4 3-1/2 3-3/4 13.2 - 2-1/2 1-1/8 13/16 13/16 1-3/4 2-1/16 2-1/16 2-3/8 4.83 - 1 4 2-3/4 2-15/16 2-3/4 3-3/4 3-1/2 3-3/4 13.52 - 1-1/2 15/16 15/16 1-13/16 2-3/16 2-3/16 2-7/16 5.14 - 1-1/8 4 2-3/4 2-7/8 2-3/4 3-3/4 3-1/2 3-3/4 14.35 - 2 1-9/16 1-9/16 1.7/8 2-7/16 2-7/16 2-9/16 5.88 6.02 1-1/2 4 2-3/4 2-7/8 2-3/4 3-3/4 3-1/2 3-3/4 13.47 - 4 2-3/4 2-13/16 2-7/16 3-1 1/16 3-1 1/16 3-1/2 14.03 - 2 1-11/16 1-7/8 2-3/4 2-11/16 2-9/16 3-1/2 11.34 - 1/2 3 2-1/8 2-1/4 2-1/8 3-1/8 2-11/16 3-1/8 7.6 - 2 2-1/2 1-7/8 1.7/8 2-5/8 2-15/16 2-13/16 3-9/16 11.6 - 3/4 3 2-1/8 2-1/8 2.1/8 3-1/8 2-11/16 3-1/8 8.25 - 3 2-1/4 2-7/16 2-11/16 3-1/4 3-1/8 3-5/8 13.44 - 1 3 2-1/8 2--1/8 2-1/8 3-1/8 2-11/16 3-1/8 8.3 - 4 2-3/4 2-3/4 2-3/4 3-3/4 3-1/2 3-3/4 13.19 - 1-1/8 3 2-1/8 2-1/8 2-1/8 3-1/8 2-13/16 3-1/8 8.46 - 2-1/2 1-7/8 1-13/16 2-5/8 2-15/16 2-13/16 3-9/16 11.78 - 1-1/2 2-1/2 1-7/8 1-7/8 2-1/8 2-13/16 2-9/16 3-1/16 7.67 - 2-1/2 3 2-1/4 2-1/8 2-11/16 3-1/4 3-1/8 3-5/8 13.06 - 1-1/2 3 2-1/8 2-3/16 2-1/8 3-1/8 2-13/16 3-1/8 8.13 - 4 2-3/4 2-3/4 2-3/4 3-3/4 3-5/8 3-3/4 15.75 - 1-1/2 1-3/8 1-1/2 2-3/16 2-5/16 2-3/16 2-13/16 6.83 - 5 3-3/8 3-1/2 2.13/16 4-3/8 4-3/8 4 22.37 - 2 1-9/16 1-9/16 2-3/16 2-9/16 2-1/4 2-15/16 7.29 - 1-1/8 15/16 15/16 2-5/8 2-5/16 2-1/4 3-5/16 9.7 - 2 2-1/2 1.7/8 1-15/16 2-1/8 2-13/16 2-9/16 3-1/16 7.1 - 1-1/2 1-7/16 1-7/16 2-11/16 2-7/16 2-3/8 3-5/16 10.2 - 3 2-1/8 2-3/16 2-1/8 3-1/8 2-15/16 3-1/8 8.79 - 3 2 1-11/16 1-9/16 2-3/4 2-11/16 2-9/16 3-1/2 10.21 10.67 2-1/2 1-7/8 1-7/8 2-5/8 2-15/16 2-13/16 3-9/16 11.25 - 1 1 15/16 2-1/8 2-1/16 1-15/16 2-11/16 5.51 3 2-1/4 2-1/6 2.11/16 3-1/4 3-1/8 3-5/8 12.5 1-1/8 1-1/4 13/16 2-1/8 2-3/16 2-1/16 2-3/4 5.92 - 4 4 2-3/4 2-11/16 2-3/4 3-3/4 3-5/8 3-3/4 15.04 - 3 2-1/2 1-1/2 1-3/8 15/16 2-3/16 2-5/16 2-3/16 2-13/16 6.23 6.33 1-1/2 1-7/16 1.3/8 2-11/16 2-7/16 2-3/8 3-5/16 10.09 - 2 1-9/16 1-1/2 2-3/16 2-9/16 2-7/16 2-15/16 6.81 - 2 11/16 1-5/8 2-3/4 2-11/16 2-5/8 3-1/2 10.9 - 2-1/2 1-7/8 1-13/16 2-1/8 2-13116 2-11/16 3-1/16 7.66 - 2-1/2 2 1-15/16 2-5/8 3 2-7/8 3-9/16 11.84 - 3 2-1/8 2-1/8 2-1/8 3-1/8 3-1/16 3-1/8 9.13 - 3-1/2 3 2-1/4 2-3/16 2-11/16 3-1/4 3-1/4 3-5/8 14.63 - 1/2 15/16 15/16 2-3/16 1-7/8 1-7/8 2-5/8 6.08 6.17 3-1/2 2-1/2 2-7/18 2-11/16 3-1/2 3-7/16 3-11/16 14.38 - 3/4 15/16 15/16 2-1/8 1-7/8 1-7/8 2-5/6 6.06 6.17 4 2-3/4 2-11/16 2-3/4 3-3/4 3-3/4 3-3/4 17.23 - 1 1 1 2-1/8 2-1/16 2-1/16 2-11/16 6.27 6.54 5 3-3/8 3-5/16 2-13/16 4-3/8 4-3/8 4 20.57 - 1-1/8 1-1/4 1-1/4 2-1/8 2-3/16 2-3/16 2-3/4 6.75 - 3/4 1-1/4 1-1/4 2-13/16 2-5/16 2-5/16 3-5/16 10.58 - 3 1-1/2 1-3/8 1-3/8 2-3/16 2-5/16 2-5/16 2-5/16 7.1 7.27 1 13/16 13/16 2-3/4 2-5/16 2-5/16 3-5/16 10.4 10.81 2 1-9/16 1-9/16 2-3/16 2-9/16 2-9/16 2-7/8 7.75 7.83 1-1/8 15/16 15/16 2-5/8 2-5/16 2-5/16 3-5/16 10.38 10.54 2-1/2 1-7/8 1-7/8 2-1/8 2-13/16 2-13/16 3-1/16 8.92 8.96 1-1/2 1-7/16 1-7/16 2-11/16 2-7/16 2-7/16 3-5/16 10.75 11.18 3-1/2 2-3/8 2-3/8 2-3/16 3-3/8 3-3/6 3-3/16 11.1 - 4 2 1-11/16 1-11/16 2-3/4 2-11/16 2-11/16 3-1/2 11.63 11.73 4 2-11/16 2-11/16 2-7/16 3-11/16 3-11/16 3-1/2 12.8 - 2-1/2 2 2 2-5/8 2-15/16 2-15/16 3-9/16 12.85 12.96 5 3-3/8 3-5/16 2-9/16 4-5/16 4-5/16 3-3/4 20.25 - 3 2-1/4 2-1/4 2-11/16 3-1/4 3-1/4 3-5/8 14.12 14.69 5 3-3/8 3-3/8 2-13/16 4-3/8 4-3/8 4 20.88 - 6 3-7/8 3-7/8 2-7/8 4-15/16 4-15/16 4-1/16 26.36 - 104 www.lakesidesupply.com Lakeside Supply Company rPipe Fittings 216-941-6800 / RI; CAST IRON THREADED FITTINGS CLASS 125, (STANDARD) Reducing Tee:Figure 359 Reducing Tee:Figure 359 Size(NPS) A B C D E F Wt(lb) Size(NPS) A B C D E F Wt.(Ibs) s x t x u (in) (in) (in) (in) (In) (in) black galv. s x t x u (in) (In) (in) (in) 2 5 3-5/16 3-9/16 3-5/16 4-1/2 4-1/4 4-1/2 22.41 - (in ) (in) black galv. 1-1/2 6 3-7/8 4-1/16 3-7/8 5-1/8 4-11/16 5-1/8 34.67 - 2-1/2 5 3-5/16 3-3/8 3-5/16 4-1/2 4-1/4 4-1/2 22.12 - 2 6 3-7/8 4 3-7/8 5-1/8 4-11/16 5-1/8 35.21 - 3 4 2-3/16 2-3/16 3-3/8 4 3-3/4 4-3/8 23.53 - 2-1/2 6 3-7/8 3-13/16 3-7/8 5-1/8 4-11/16 5-1/8 34.57 - 6 3-13/16 4-1/16 3-3/8 5 5 4-5/8 31.13 - 3 4 2-13/16 3 3-7/8 4-1/16 4 4-15/16 32.25 - 3 2-5/16 2-1/2 3-1/4 3-1/2 3-1/2 4-1/4 23.22 - 3-1/2 6 3-7/8 3-7/8 3-7/8 5-1/8 4-15/16 5-1/8 35.31 - 3-1/2 4 2-13/16 2-11/16 3.3/8 4 3-3/4 4-3/8 22.76 - 3 2-5/16 2-1/2 3-7/8 3-9/16 3-9/16 4-13/16 31.75 - 6 3-13/16 4 3-3/8 5 5 4-5/8 29.26 - 4 4 2-7/8 2-15/16 3-7/8 4-1/16 4 4-15/16 30 - 2-1/2 2-1/16 2 3-3/16 3-3/16 3-1/16 4-1/4 21.81 - 6 3-7/8 3-7/8 3-7/8 5-1/8 4-15/16 5-1/8 34.22 - 3 2-5/16 2-7/16 3-1/4 3-1/2 3-1/2 4-1/4 24.05 - 1-1/2 1-5/8 1-9/16 3-7/8 2-3/4 2-3/4 4-1/2 25.81 - 5 4 4 2-13/16 2-3/4 3-3/6 4 3-3/4 4-3/8 20.58 - 6 3-1/2 2-5/8 2-9/16 3-13/16 3-7/8 3-3/4 4-7/8 30.34 - 5 3-5/16 3-3/8 3-5/16 4-1/2 4-3/8 4-1/2 26.33 - 5 6 3-7/8 3-15/16 3-7/8 5-1/8 5-1/8 5-1/8 43.31 - 6 3-13/16 3-7/8 3-38 5 5 4-5/8 33.51 - 8 5-1/8 5-3/16 4-3/16 6-3/8 6-3/8 5-9/16 65.79 - 1-1/2 1-9/16 1-9/16 3-5/16 2-11/16 2-11/16 4 16.21 - 1-1/8 1-3/8 1-3/8 3-13/16 2-5/8 2-5/6 4-7/16 22.36 - 2 1-3/4 1-3/4 3-7/16 2-15/16 2-15/16 4-1/8 17.43 - 2 1-13/16 1-13/16 3-7/8 3 3 43/6 24.65 - 2-1/2 2-1/16 2-1/16 3-3/8 3-3/16 3-3/16 4-1/4 18.84 - 2-1/2 2 2 3-13/16 3-1/4 3-1/4 4-3/4 25.67 27 5 3 2-5/16 2-5/16 3-1/4 3-1/2 3-1/2 4-1/4 20 - 6 3 2-3/8 2-3/8 3-13/16 3-9/16 3-9/16 4-13/16 27.46 28.56 4 2-13/16 2-13/16 3-3/8 4 4 4-3/8 23.83 - 4 2-7/8 2-7/8 3-7/8 4-1/16 4-1/16 4-15/16 32.44 33.74 6 3-13/16 3-13/16 3-3/8 5 5 4-5/8 32.91 - 5 3-38 3-3/8 3-13/16 4-5/8 4-5/8 5 37 - 8 5-3/16 5-3/16 4-3/16 6-3/8 6-3/8 5-9/16 67.92 - 8 5-1/8 5-1/8 4-3/16 6-3/8 6-3/8 5-9/16 58.05 - 2 8 5-3/16 5-7/8 5-3/16 6-9/16 6-9/16 6-9/16 64 - 4 8 5-3/16 5-1/2 5-3/16 6-9/16 6-9/16 6-9/16 67 - 5 5 4-3/16 4-3/8 5-3/16 5-9/16 5-9/16 6-3/8 77.58 - 5 4-3/16 4-5/16 5-3/16 5-9/16 5-9/16 6-3/8 76.6 - Most cast iron fittings are 6 6 4-3/16 4-5/16 5-1/8 5-9/16 5-9/16 6-3/8 73.72 - 8 5-3/16 5-1/8 5-3/16 6-9/16 6-9/16 6-9/16 91.5 - available in galvanized finish. 8 2 2-1/16 2-1/16 5-1/8 3-7/16 3-7/16 5-7/8 44.49 - 2-1/2 2-5/16 2-5/16 5-1/16 3-11/16 3-11/16 6 45.23 - Ask your salesperson for details 3 3-1/8 3-1/8 5-1/8 4-1/2 4-1/2 6-1/8 54.97 - 8 3-1/2 3-1/8 3-1/8 5-1/8 4-1/2 4-1/2 6-18 54.21 - and lead time. 4 3-1/8 3-1/8 5-1/8 4-1/2 4-1/2 6-1/8 53.62 - 5 4-3/16 4-3/16 5-3/16 5-9/16 5-9/16 6-3/8 67.81 - 6 4-3/16 4-3/16 5-1/8 5-9/16 5-9/16 6-3/8 66.22 - Straight Cross Figure 360 I F lj- Size A B Weight(Ibs) Size A B Weight(Ibs) (NPS) (in) (in) black (NPS) (In) (in) black 1/2 13/16 9/16 2.80 2-1/2 2-11/16 1-13/16 8.07 3/4 1-5/16 13/16 1.03 3 3-1/8 2-3/16 11.84 1 1-1/2 15/16 1.59 4 3-13/16 2-3/4 19.63 1-1/4 1-3/4 1-1/8 2.42 5 4-1/2 3-5/16 31.16 1-1/2 1-15/16 1-5/16 3.21 6 5-1/8 3-7/8 47.67 2 2-1/4 1-9/16 5.08 www.lakesidesvpply.com 105 Pipe Fittings Lakeside Supply Company . ) 210-9416800 . AiwIL CAST IRON THREADED FITTINGS CLASS 125, (STANDARD) Reducing Cross Figure 361 I PIERM=1-FT 2 NPS f .- 11111.4r ? H 3 NPS ± 2-1/2NPS 1-1/4 NPS A ,.. 13 -ti Read as; 3 z 2-1/2 z 2 z1-1/4 1 Size(NPS) A B C D E,F G,H Wt.(Ibs) (in) (in) (in) (in) (in) (in) black 1 1 3/4 3/4 13/16 13/16 15/16 15/16 1-3/8 1-7/16 1.30 1-1/4 1-1/4 1 1 15/16 15/16 1-1/8 1-1/8 1-9/16 1-11/16 2.04 1 1 1 1 1-1/8 1-1/4 1-1/4 1-5/8 1-13/16 2.74 1-1/4 1 1 1 1 1-1/4 1-1/4 1-5/8 1-13/16 2.67 1-1/2 1 1 1 1 1-1/4 1-1/4 1-5/8 1-13/16 2.51 1-1/2 1 1-1/8 1-1/8 13/16 15/16 1-13/16 1-7/8 3.90 1-1/4 1-1/4 1-1/8 1-1/8 1-3/8 1-3/8 1-13/16 1-7/8 3.95 1 1 11/16 1-1/8 1-7/16 1-7/16 1-3/4 2 3.57 1-1/2 1-1/4 1 1-1/8 13/16 1-1/2 1-7/16 1-7/8 2-1/8 4 25 1-1/4 1-1/4 13/16 13/16 1-1/2 1-1/2 1-7/8 2-1/16 4.18 2 1 1 11/16 11/16 1-7/16 1-7/16 1-3/4 2 3.22 2 1-1/4 1-1/4 1-1/8 1-1/8 1-7/16 1-7/16 1-7/8 2-1/8 4.00 1-1/2 1-1/2 1-1/4 1-1/4 1-7/16 1-7/16 2 2-1/8 4.08 1-1/4 1-1/4 1-1/8 13/16 1-13/16 1-13/16 2-1/16 2-3/8 6.01 1-1/2 1-1/2 1 15/16 1-9/16 1-7/8 1-13/16 2-3/16 2-7/16 6.51 1 1 1 11/16 1-13/16 1-13/16 1-15/16 2-5/16 5.11 1 1-1/8 13/16 1-13/16 1-13/16 2-1/6 2-3/8 5.86 1-1/4 2 1-1/4 1-1/8 13/16 1-13/16 1-13/16 2-1/16 2-3/8 5.88 1-1/2 1-1/2 1-1/4 15/16 1-7/8 1-7/8 2-3/16 2-7/16 6.13 2-1/2 2 2 1-1/2 1-3/4 1-7/8 1-7/8 2-7/16 2-9/16 7.23 1 1 1 1 1-13/16 1-13/16 1-15/16 2-5/16 5.06 1 13/16 13/16 1-3/4 1-13/16 2-1/16 2-3/8 5.39 2-1/2 1-1/41-1/4 1-1/8 1-1/8 1-13/16 1-13/16 2-1/16 2-3/8 5.26 1-1/4 1-1/4 1-1/4 1-13/16 1-13/16 2-3/16 2-7/16 5.56 1-1/2 1-1/2 1-1/4 1-1/4 1-7/8 1-7/8 2-3/16 2-7/16 5.68 2 2 1-9/16 1-9/16 1-15/16 1-15/16 2-7/16 2-9/16 6.82 1 1 11/16 1-1/8 2-1/8 2-1/8 2-1/16 2-11/16 7.47 2-1/2 1-1/2 1-1/2 1-3/8 1-7/16 2-3/16 2-3/16 2-5/18 2-13/16 8.37 2 2 1-5/8 1-11/16 2-1/4 2-1/4 2-9/16 2-15/16 9.62 1 1 11/16 11/16 2-1B 2-1/8 2-1/16 2-11/16 6.70 1-1/4 1-1/4 13/16 13/16 2-1/8 2-1/8 2-3/16 2-3/4 7 21 3 1-1/4 1-3/8 1-3/8 2-3/16 2-3/16 2-5/16 2-13/16 7.92 1-1/2 3 1-1/2 1-3/8 1-3/8 2-3/16 2-3/16 2-5/16 2-13/16 7.91 1-1/2 1-5/8 1-5/8 2-3/16 2-3/16 2-9/16 2-15/16 9.25 2 2 1-5/8 1-5/8 2-3/16 2-3/16 2-9/16 2-15/16 8.85 2-1/2 2-1/2 1-7/8 1-7/8 2-3/16 2-3/16 2-13/16 3-1/16 9.96 1-1/2 1-1/2 1-3/8 1-7/16 2-7/16 2-7/16 2-3/8 3-1/16 10.28 3 2-1/2 2-1/2 1-7/8 1-15/16 2-7/16 2-7/8 2-7/8 3-5/16 13.07 3-1/2 1-1/4 1-1/4 1-1/4 1-1/4 2-3/8 2-3/8 2-1/4 3 9.09 3-1/2 1-1/2 1-1/4 1-3/8 1-3/8 2-7/16 2-7/16 2-3/8 3-1/16 9.75 3 1-1/2 1-1/2 1-3/8 1-7/16 2-11/16 2-5.8 2-7/16 3-5/16 13.50 3 2 2 1-5/8 1-11/16 2-13/16 2-13/16 2-11/16 3-1/2 13.50 3-1/2 1-1/4 1-1/4 1-1/4 15/16 2-11/16 2-11/16 2-5/16 3-5/16 11.47 1 1 1-1/4 1-1/4 2-3/4 2-3/4 2-5/16 3-5/16 11.09 1-1/4 1-1/4 1-1/4 1-1/4 2-11/16 2-11/16 2-5/16 3-5/16 10.75 1-1/2 1-1/2 1-3/8 1-3/8 2-11/16 2-11/16 2-7/16 3-5/16 11.82 4 1-1/2 2 2 2-7/8 2-11/16 2-15/16 3-9/16 14.38 4 2-1/2 2 1-7/8 1-7/8 2-11/16 2-7/8 2-15/16 3-9/16 14.88 2-1/2 2 2 2-11/16 2-11/16 2-15/16 3-9/16 14.07 3 3 2-3/16 2-3/16 2-11/16 2-11/16 3-1/4 3-5/8 15.51 3-1/2 3-1/2 2-11/16 2-11/16 2-3/4 2-3/4 3-3/4 3-3/4 21.44 4 2 1-11/16 1-11/16 2-11/16 2-11/16 2-3/4 3-7/16 12.00 106 wvvw.lakesidesupply.com Lakeside Supply Company Pipe Fittings (JrAISIV1U CAST IRON THREADED FITTINGS CLASS 125, (STANDARD) �E� -F_ 2 NPS Reducing Cross Tr Figure 361 11 . �� 40 lifleisami H 3 NPS 2-1/2 NPS -- A 6 - - - 1-1/4NPS i Read as: ; --ice; 3 x 2-1/2 x 2 x 1-1/4 i A B C D E,F G,H WI.(Ibs) Size(NPS) (in) (in) (in) (in) (in) (In) black 4 1-1/2 1-1/2 1-1/2 1-5/8 3-3/8 3-3/8 2.11/16 4 18.81 5 2-1/2 2 2 2-1/8 3-5/16 3-9/16 3-3/16 4-1/4 22.47 5 2 2 1-3/4 1-3/4 3-7/16 3-7/16 2-15/16 4-1/8 18.25 3 3 2-5/16 2-5/16 3-5/16 3-5/16 3-1/2 4-5/16 22.91 1-1/2 1-1/2 1-1/2 1-9/16 3-7/8 3-7/8 2-3/4 4-1/2 25.75 5 2 2 1-3/4 1-13/16 3-15/16 3-15/16 3 4-5/8 28.44 3 3 2-5/16 2-3/8 3-7/8 3-7/8 3-9/16 4-13/16 32.88 6 1-1/4 1-1/4 1-3/8 1-3/8 3-13/16 3-13/16 2-5/8 4-7/16 22.88 6 2-1/2 2-1/2 2 2 3-7/8 3-7/8 3-1/4 4-3/4 26.44 4 4 2-13/16 2-13/16 3-7/8 3.7/8 4-1/16 4-15/16 33.4 5 5 3-3/8 3-3/8 3-13/16 3-13/16 4-5/8 5 39.25 8 8 4 4 3-1B 3-1/8 5-1/16 5-1/16 4-1/2 6-1/8 55.56 5 5 4-3/16 4-3/16 5-3/16 5-3/16 5-9/16 6-3/8 80.44 Lateral Weight Figure 373 Size A B C D (Ibs) (NPS) (in) (in) (in) (in) black g 3/4 1/4 1-3/4 3/4 2-1/4 1.00 Return Bends Center to N 1 3/16 2-3/16 3/4 2-3/4 1.62 Open Size Center Weight(Ibs) 1-1/4 3/8 2-5/8 1 3-1/4 2.63 Figure 376 (NPS) (in) black 1-1/2 7/16 3-3/16 1-1/16 3-13/16 3.57 1/2 1-1/2 - 2 9/16 3-13/16 1-1/4 4-1/2 5.75 3/4 1-7/8 .98 : ••-- _* 2-1/2 5/8 4-5/16 1-1/2 5-3/16 8.991.17H 1 2-1/2 1.48 3 13/16 5-3/16 1-3/4 6-1/8 13.54 w (~ # 1-1/4 3 2.41 4 1-1/16 6-9/16 2-1/8 7-5/8 21.30 9 : 1-1/2 3-1/2 3.33 MIPM1111111\ DI Dif, 2 CTmuq Special Wide Pattern Center to Wei ht lbs TA Figure 377 Size Center g ( ) (NPS) (In) black galv. 1 4 2.20 ,. 1-1/4 4 3.50 Return Bends 1-1/4 6 3.74 • Close Pattern,R.H. Center to Size Center Weight bs) if: tt Figure 375 (NPS) (in) black •Not Stocked in 1/2 1-1/4 .65 _..:.. ... 3/4 1-1/2 1.10 1 1-3/4 1.71 - 41-1/4 2-1/4 2.39 1-1/2 2-1/2 3.46 .... m, ---_-, www.fakesdesupply.cam 107 Pipe Fittings Lakeside Supply Company 216-941-6800 " �.0 CAST IRON THREADED FITTINGS CLASS 125, (STANDARD) Flange Union Eccentric Reducer Gasket Type Fla of Weight(Ibs) Figure 368 Size A B Weight(Ibs) Figure 487 Size Flangng of No.of (NPS) (in) (in) black galv. (NPS) (in) bolts black gals. 3/4 1/2 9/16 1-1/2 .45 - Assembled with gaskets 1/2 2-15/16 3 1.75 1.80 1/2 1/2 1-7/16 .57 - 3/4 3 3 2.00 2.05 1 3/4 7/16 1-1/2 .61 - 1 3-1/4 3 2.25 2.30 1/2 9/16 1-5/8 1.00 - 1-1/4 4-3/16 4 4.75 4.85 1-1/4 3/4 1/2 1-5/8 .90 - 1-1/2 4-3/8 4 5.00 5.10 1 1/2 1-11/16 1.00 - 2 5 4 6.50 6.65 1/2 11/16 1-3/4 1.11 - „ . + - 2-1/2 5-5/8 4 8.50 8.65 3/4 9/16 1-11/16 1.17 - 3 6-3/8 4 11.00 11.20 11/2 1 9/16 1-3/4 1.21.€ - .... 3-1/2 6-7/8 4 12.75 13.00 1-1/4 5/8 1-7/8 1.26 - 4 7-11/16 5 18.00 18.50 .,; 1/2 3/4 1-15/16 1.80 - 5 8-15/16 5 22.00 22.75 + .l ; 3/4 3/4 2 1.83 - 6 10-1/4 6 30.00 31.00 '-' - + 2 1 11/16 2-1/16 1.86 - 8 12-15/16 8 51.00 52.50 1-1/4 13/16 2-1/8 1.87 - 1-1/2 7/8 2-3/16 1.93 - 1 13/16 2-1/4 2.74 - 2-1l2 1-1/4 7/8 2-3/8 2.80 - B 1-1/2 7/8 2-3/8 2.94 2 1 2-9/16 2.95 Concentric ReIN ducers Size A B Weight Ibs ' 1 7/8 2-7/16 3.95 - Figure 367 g ( ) 1-1/4 15/16 2-9/16 3.80 = (NPS) (in) (in) black 3/4 1/2 5/8 1-9/16 .40 3 1-1/2 15/16 2-9/16 4.16 1/2 11/16 1-11/16 .54 2 1-1/16 2-3/4 4.61 - 1 2-1/2 15/16 2-13/16 4.80 - 3/4 7/16 1-1/2 .63 2 1-1/16 2-3/4 5.23 - 1/2 9/16 1-5/8 .84 3-1/2 3 15/16 2-15/16 6.04 ■ 1-1/4 3/4 1 2-1/8 1.07 1 1-1/16 2-11/16 6.83 - 1 15/16 2-1/8 1.07 1-1/4 1-1/16 2-3/4 6.58 - 1/2 1/2 1-5l8 1.00 1-1/2 1-1/8 2-13/16 6.61 - 1-1/2 3/4 1/2 1-5/8 1.20 4 2 1-3/16 2-15/16 6.91 - B 1 1/2 1-3/4 1.50 2-1/2 1-1/8 3-1/16 7.26 qy 1-1/4 1 2-1/4 1.45 3 1-1/16 3-1/8 7.64 1/2 5/83/4 2 2.00 2-1/2 1-1/8 3-3/16 11.38 - 2 3/42 3/4 2 1.90 1-1/4 13/16 2-1/8 1-1/2 7/8 2-3/16 1.83 1.78 5 3 1-1/16 3-1/4 11.44 - 4 1-1/16 3-5/16 11.19 - 3 1-1/16 3-5/16 14.66 - 1.98 1-1/2 3/4 2 3.10 6 4 1-1/8 3-7/16 15.36 - 2-1/2 2 1 2-9/16 2.98 5 1-1/8 3-9/16 18.00 - 3/4 15/16 2-1/2 4.31 8 5 1-5/16 3-3/4 28.14 - 6 1-1/4 3-7/8 28.04 - 3 2 1-1/16 2-3/4 3.96 2-1/2 15/16 2.13/16 4.40 2 1-3/16 2-15/16 6.50 4 2-1/2 1-3/16 3-1/8 7.78 3 1-1/16 3-1/8 7.01Or ders 4 1-1/16 3-5/16 10.48 we receive for UPS 6 4 1-1/8 3-7/16 13.83 5 1-1/8 3-9/16 15.53 delivery by 3:30 P.M. will be 8 6 1-1/4 3-7/8 29.10 shipped the same day. Ask your salesperson for other delivery options. 108 www.lakesidesupply.com lakeside Supply Company pipe Fittings 216-941-6800 �.--•.:''--.... ' ' f- k'111 / ,.,� .4 CAST IRON THREADED FITTINGS CLASS 125, (STANDARD) Hex Bushing Size Weight(Ibs) Hex Bushing Size Weight(Ibs) Figure 383 (NPS) black galv. Figure 383 (NPS) black galv. 1/4 1/8 .021 .022 2 5.12 5.24 3/81/8 .045 .047 2-1/4 4.87 5.06 1/4 .038 .039 5 3 4.83 4.93 1/8 .060 .062 3-1/2 4.00 4.30 1/2 1/4 .070 .073 4 3.94 4.10 3/8 .050 .053 2 8.00 8.32 1/8 .090 .093 2-1/2 7.72 7.78 1/4 .100 .105 Continued from 3 7.75 8.06 3/4 3/8 .119 .121 previous column. 6 3-1/2 7.13 7.40 1/2 .103 .105 4 6.83 7.11 1/8 .208 .216 5 5.24 5.45 1/4 .186 .192 3 15.50 15.8 1 3/8 .182 .188 4 13.93 15.0 1/2 .215 .220 8 5 13.65 14.0 3/4 .170 .174 6 13.19 13.5 1/4 .290 .300 4 27.5 - 3/8 .290 .295 5 - - 1-1/4 1/2 .300 .305 10 6 24.5 - 3/4 .385 .393 8 22.0 - 1 .296 .302 4 32.5 - 1/4 .470 .490 12 10 32.5 33.0 3/8 .470 .500 1-1/2 1/2 .420 .470 3/4 .470 .500 Size Weight(Ibs) 1 .500 .520 (NPS) black galv. 1-1/4 .327 .334 1/4 1/8 .009 - r' 1-1/4 .810 .830 3/8 114 .015 - 1-1/2 .667 .680 Face Bushing 1/2 1/4 .040 - -, , 1/4 .750 .800 Figure 385 3/8 .030 - 2 3/8 .750 .780 3/4 3/8 .065 .065 1/2 .770 .780 1/2 .055 .055 3/4 .710 .750 1 1/2 .120 .125 1 .730 .760 •+ 3/4 .085 .090 1-1/4 .810 .830 1/2 .245 - I 1/2 1.280 - 1-1/4 3/4 .268 - 3/4 1.250 1.290 1 .160 .165 2.1/2 1 1.160 1.230 1/2 .320 .330 1-1/4 1.240 1.250 1-1/2 3/4 .391 .398 1-1/2 1.290 1.340 1 .339 .346 2 .920 .950 1-1/4 .145 .150 1/2 1.93 2.01 1/2 .695 - 3/4 1.92 1.95 2 1 .525 .535 1 1.90 1.92 1-1/4 .540 .549 3 1-1/4 1.77 1.80 1-1/2 .345 .350 1-1/2 1.79 1.83 1-1/4 .935 .960 2 1.90 1.94 2-1/2 1-1/2 .850 .870 I 2-1/2 1.63 1.66 2 .615 .620 1 2.65 2.75 1-1/4 1.540 - 1-1/4 2.54 2.64 3 1-1/2 1.500 1.560 3-1/2 1-1/2 2.32 2.38 2 1.330 1.380 2 2.42 2.48 2-1/2 .970 1.020 2-1/2 2.56 2.61 3-1/2 2-1/2 1.760 - 3 1.96 1.98 1 3.59 3.63 1-1/4 3.54 3.60 Note:Hexagon head or octagon head bushings 2-1/2 NPS and smaller reducing one 1-1/2 3.44 3.50 size may be made o1 malleable Iron,ductile iron or steel.Other sizes may be made 4 2 3.11 3.24 01 cast iron,ductile iron,malleable iron or steel.Face busing 2-1/2 NPS and smaller may be made of malleable iron ductile iron or steel.Face bushings 3 NPS and larger 2-1/2 3.29 3.33 reducing one size may be made of malleable iron,ductile iron or steel.Face bush- 3 3.15 321 ings 3 NPS and larger reducing two sizes or more may be made of cast or malleable 3-1/2 2.50 2.58 iron,ductile iron,or steel. According to specifications,hex bushings and cored plugs should be used with 150# malleable iron and 125#cast iron.Solid plugs and face bushings should be used with #250 and#300 fittings. _e ... n �n rn fir.. if -- n - t . akesidesupply.com 109 Pipe Fittings Lakeside Supply Company ,,..-K ; ..----, .r : ,..,,.k,I•,,' _ 216-941-6800 v')AInw!L CAST IRON THREADED FITTINGS CLASS 125, (STANDARD) Square Head Size Weight Ibs Countersunk Plugs(Cored) g ( ) Plugs Size Weight(Ibs) Figure 387 (NP1/S) black galv. Figure 390 (NPS) black galv. 1/2 .050 .053 3/4 .132 .135 3/4 .090 .100 1 .250 .281 1 1 .195 .200 5 1-1/4 .391 .407 1-1/4 .320 .340 -=' 1-1/2 .500 .515 2 .815 .833 - 2 .840 1.3 2-1/2 1.320 1.340 2-1/2 1.400 2.0 3 1.870 1.910 3 2.250 3.0 3-1/2 2.500 2.600 3-1/2 3.020 - 4 4.00 4.000 4 3.760 3.9 Cap Size Weight(Ibs) Figure 381 (NPS) black galv. 2-1/2 2.55 - 3 4.10 - Square Head Size Weight(Ibs) 4 6.40 Plugs(Solid) Figure 388 (NPS) black galv. 5 10.70 - 1/2 .100 .104 6 14.20 14.60 .qr 3/4 .169 .175 8 27.23 28.35 ('- " 1 .320 333 . ' -- 1-1/2 .760 .770 2 1.230 1.250 2-1/2 2.000 2.080 3 3.180 3.310 3-1/2 4.380 - Locknut Min.Dimensions Weight(Ibs) Figure 370 Size A B C D (NPS) (in) (in) (in) (in) blk. galv. 2-1/2 3.500 3.180 .590 .090 1.13 1.16 3 4.270 3.840 .670 .090 1.60 1.70 4 5.380 5.000 .800 .130 3.50 - Bar Plugs(Cored) Size Weight(Ibs) Figure 369 (NIPS) black galv. 4 3.82 3.97 v 5 6.50 6.83 '.` 6 9.94 10.34 Floor Flange dia.of dia.of Weight 8 20.26 21.00 Bolt Holes Cored Size flange no.of holes (Ibs) Size Weight(Ibs) Figure 1006 (NPS) (in) holes (in) black galv. Bar Plugs(Cored) (NPS) black galv. 1/4 2-13/16 4 1/4 .39 .40 Figure 380 4 5.68 - 3/8 3 4 1/4 .43 .45 5 9.60 - ` ' 1/2 3-1/2 4 1/4 .73 .74 6 14.78 - .-, 3/4 3-1/2 4 1/4 .80 .81 8 - - r -T" 1 4 4 1/4 1.13 1.14 1-1/4 4 4 1/4 1.14 1.15 1-1/2 4-1/2 4 5/16 1.55 1.56 2 5-1/2 4 5/16 2.40 2.43 We also stock hex head and magnetic pipe plugs. Your salesperson will be happy to fulfill your requirements. I i 7 70 wwvv.takesidesupply.com 1,akeside Supply Company *1- Pipe Fittings 216-941-6800 *-- -' l-m`7:7117:74.-ACPC'PP 7 PP '' - ` )# '!),- 1"--41 "MPSA .#0._ ‘. A A - A .„-,.. M4AMMNIA-: CAST IRON THREADED FITTINGS CLASS 250 (EXTRA HEAVY) 90°Elbow 45'Elbow Fi Size A B Weight(Ibs) Size A B Weight(Ibs)gure 421 ure 424 (NPS) (in) (in) black Fig (NPS) (in) (in) black 1/4 5/8 15/16 .37 1/2 9/16 1 .66 3/8 11/16 1-1/16 .50 3/4 5/8 1-1/8 1.04 1/2 13/16 1-1/4 .75 1 3/4 1-5/16 1.56 ' 2(Sici 3/4 15/16 1-7/16 1.13 1-1/4 7/8 1-1/2 2.70 .., 1 1-1/16 1-5/8 1.79 1-1/2 1-1/16 1-11/16 3.55 1-1/4 1-5/16 1-15/16 3.00 2 1-5/16 2 6.07 I-1-B-P-I 1-1/2 1-1/2 2-1/8 4.05 2-1/2 1-5/16 2-1/4 9.79 2 1-13/16 2-1/2 6.76 s</?\1 3 1-9/16 2-1/2 13.83 2-1/2 2 2-15/16 10.56 4 1-3/4 2-13/16 22.60 13jt A /3 2-3/8 3-3/8 15.25 A 6 2-1/4 3-1/2 50.20 3-1/2 2-3/4 3-3/4 20.20 / 4 3-1/16 4-1/8 26.15 B 1 e 5-5/8 7 122.00 Straight Tee Reducing Tee Size A B Weight(Ibs) Size A,B C D,E F Weight(lbs) Figure 425 Figure 426 (NPS) (in) (in) black (NM (in) (in) (in) (In) black 1/4 5/8 15/16 .47 3/4 3/4 1/2 3/4 7/8 1-5/16 1-3/8 1.37 3/8 11/16 1-1/16 .70 1 1 1/2 3/4 1 1-3/8 1-1/2 2.03 1/2 3/4 1-1/4 1.20 _ ''. 3/4 7/8 1 1-1/2 1-9/16 2.19 3/4 7/8 1-7/16 1.57 3/4 15/16 1-1/8 1-5/8 1-11/16 3.21 1 1 1-5/8 2.43 -1, 1-1/4 1-1/4 1 1-1/16 1-3/16 1-3/4 1-13(16 3.49 1-1/4 1-3/16 1-15/16 3.94 f ...,.. 1-1/4 1-5/16 1-3/8 2 2-1/16 4.98 1-1/2 1-7/16 2-1/8 5.31 ' 41--;(-1 1 1-1/8 1-5/16 1-13/16 1-15/16 426 2 1-3/4 2-1/2 9 01 1-1/2 1-1/2 3/4 1 1-1/4 1-11/16 1-7/8 4 02 I--B-P-k-B--%1 1--D-Pr-E-I 2-1/2 1-15/16 2-15/16 14.23 1-1/2 1-1/2 1-5/8 2-5/16 2-5/16 7 69 A%PHA 3 2-5/16 3-3/8 20.95 A ' B 3/4 1-1/8 1-7/16 1-7/8 2 6.24 -T 4 2-15/16 4-1/8 33.98 -4-1--- f- 2 2 1 1-1/4 1-1/2 2 2-1/8 6.57 - --- A B C 1 F 1-1/4 1-3/8 1-9/16 2-3/16 2-1/4 7.11 1 J_ 1... I' D Safety valve discharge Elbow-Cast iron T i IIIIIMIall C Threaded inlet:Figure 1538 L Gd Flanged inlet:Figure 1538F iiiMpf ' i Mgr F/i IVI-31 . Pipe TapJ Elbow Riser Pipe Pipe Weight Weight Size Size B C D E F G H J K L Figure Figure (NPS) A(In) On) (in) (in) (in) (in) (in) (in) (in) (In) (in) 1538 1538F 2-1/2 3-1/2 2-11/16 4-5/16 8-1/2 1-5/8 _ 1-15/16 2-1/8 2-3/4 3/4 - - 12.00 - 3 4 3-1/8 4-7/8 9-1/2 1-5/8 2-5/16 2-9/16 3-1/8 3/4 - - 15.00 3-1/2 5 3-7/16 5-5/16 10-1/4 1-3/4 2-5/8 2-7/8 3-7/16 3/4 - - 24.00 - 4 5 3-3/4 5-3/4 11 1-3/4 2-15/16 3-3/16 3-3/4 3/4 - , - 27.00 - 5 6 4-1/2 6-3/4 12-1/2 1-7/8 . 3-9/16 3-15/16 4-3/8 3/4 - - 40.00 - 6 8 5-1/8 7-5/8 13-3/4 2 , 4-3/16 4-9/16 5 3/4 - - 53.00 - 8 10 6-9/16 8-9/16 17 2-3/8 5-3/8 5-15/16 6-3/8 1 10-3/4 13-1/2 104.00 140 00 ç. . www.lakesidesupply.com 111 Pipe Fittings Lakeside Supply Company 216-941-6800 Awn: CAST IRON FLANGED FITTINGS CLASS 125, STANDARD 90°Straight Elbow Thickness 45°Straight Elbow Thickness Figure 801 Flange Min. Figure 802 9 Flange Min. Size A Diam. Flange Wall Weight Size A Diam. Flange Wall Weight (NPS) (in) (in) (in) (in) (Ibs) (NPS) (in) (in) (in) (in) (Ibs) • t' 1-1/2 4 5 9/16 5/16 9 ' 1-1/2 2-1/4 5 9/16 5/16 8 2 4-1/2 6 5/8 5/16 14 2 2-1/2 6 5/8 5/16 12 `.k-.:„r: 2-1/2 5 7 11/16 5/16 19 •`'" ,;... 2-1/2 3 7 11/16 5/16 17 3 5-1/2 7-1/2 3/4 3/8 24 3 3 7-1/2 3/4 3/8 20 3-1/2 6 8-1/2 13/16 7/16 31 3-1/2 3-1/2 8-1/2 13/16 7/16 27 4 6-1/2 9 15/16 1/2 41 4 4 9 15/16 1/2 36 5 7-1/2 10 15/16 1/2 52 5 4-1/2 10 15/16 1/2 45 A 6 8 11 1 9/16 68 6 5 11 1 9/16 60 8 9 13-1/2 1-1/8 5/8 110 8 5-1/2 13-1/2 1-1/8 5/8 94 10 11 16 1-3/16 3/4 175 0 10 6-1/2 16 1-3/16 3/4 145 12 12 19 1-1/4 13/16 250 12 7-1/2 19 1-1/4 13/16 220 Concentric Reducer Eccentric Reducer Figure 825 Size F Weight Figure826 Size F Weight (NPS) (In) (Ibs) (NPS) (in) (Ibs) 2 1-1/2 5-1/2 12 2 16 rve" 2-1/2 1-1/2 5-1/2 14 3 2-1/2 6 22 2-1/2 5-1/2 12 - fir 2 28 14t 1-1l2 14 *killiN 4 2-1l2 7 28 3 2 6 16 I< 3 28 2-1/2 19 5 4 8 39 2 24 3 47 4 2-1/2 7 26 6 4 9 50 3 28 I 5 51 --rtt 3-1/2 31 I_ 4 71 2-1/2 31 ' ' 8 5 11 76 �F� 5 3 8 32 I 6 77 4 39 f*-�F� 6 107 2 34 10 6 12 /20 2-1/2 37 8 155 6 3 9 39 72 10 14 180 4 47 5 50 4 66 8 5 11 71 6 77 4 85 Special finishes are available 10 5 12 90 6 100 for flanged cast iron fittings 8 120 6 140 including epoxy coating and 12 8 14 155 10 180 hot dip galvanized. Ask us for price and availability. 112 www,kikesidesupply.com Lakeside Supply Company Pipe Fittings 216-941-6800 x /s IL CAST IRON FLANGED FITTINGS CLASS 125, STANDARD Taper Reducing Elbow Size A Weight Figure 803 (NPS) (in) (Ibs) /$ 2 1/2 2 5 18 2 19 3 21/2 5-1/2 22 £ r. 2 29 4 2-1/2 6-1/2 31 t 3 33 40 5 4 7-1/2 48 A-.1 3 47 6 4 8 56 5 60 A 4 77 8 5 9 82 6 90 10 6 11 125 8 150 6 165 12 8 12 190 10 220 Long Radius Thickness Long Radius Elbow Reducing Elbow Flange Flange Reducing Size B Weight Straight Size B Diam. (min.) Wall Weight Figure 904R (NPS) (in) (Ibs) Figure 804 (NPS) (in) (in) (In) (in) (Ibs) 3 x 2 7-3/4 23 2 6-1/2 6 5/8 5/16 16 - 4 x 3 9 46 2 1/2 7 7 11/16 5/16 23 ' 5 x 4 10-1/4 58 3 7.3/4 7-1/2 3/4 3/8 28 -.. . 6 x 4 11-1/2 78 4 9 9 15/16 1/2 48 6 x 5 81 6 11-1/2 11 1 9/16 85 ` 8 x 6 14 130 �.m... 8 14 13-1/2 1-1/8 5/8 145 - 10x8 16-1/2 205 10 16-1/2 16 1-3/16 3/4 230 8--.-I 12 19 19 1-1/4 13/16 350 8—i-1 Base Elbow Center Dia.of Thickness Size of Figure 805 Size to Base Round Base Base Rubs Supporting Pipe Weight ... (NPS) R(in) S(in) T(in) U(in) for Base(in) (Ibs) 3 4-7/8 5 9/16 1/2 2 36 4 5-1/2 6 5/8 1/2 2 59 5 6-1/4 7 11/16 5/8 2-1/2 76 ( t 6 7 7 11/16 5/8 2-1/2 110 ' 8 8-3/8 9 15/16 7/8 4 158 10 9-3/4 9 15/16 _ 7/8 4 224 12 11-1/4 11 1 1 6 324 fl Bases,when drilled,should be drilled to the template of the flange of the supporting pipe size. Size of base determined by size of largest opening of fitting. .,_5� Bases will be furnished not faced and not drilled unless otherwise specified.When ordered faced,dimensions"R"and'T"will be slightly less than shown in table. iw-. 10 1.ilt.lwt Ili":VIA. If OW .� , ,N. (t ..(.1._. rr, i.;M.'1 . - =-� _.. M.. `._ � t vintriv„kikesiclesupply.gam113 Pipe Fittings t Lakeside Supply Company 4 216-941-6800 p S )r . 'I,,t ... .1„_..,. ,14 i;.. fil '. t.Cm ,: ..I".*/.11A. . .-ire,-- 57 A. iz 111uv L CAST IRON FLANGED FITTINGS CLASS 125, STANDARD Side Outlet Straight Tee Elbow Figure 811 Figure 808 ,,,,� - Flange Thickness Size A AA Dia. Flange Wall Weight I (NPS) (in) (in) (in) (in) (in) (lbs) t 1-1/2 4 8 5 9/16 5/16 15 2 4-1/2 9 6 5/8 5/16 21 Flange Thickness Size A Diam. Flange Wall Weight 2-1/2 5 10 7 11/16 5/16 30 --.i (NPS) (in) (in) (in) (In) (Ibs) 3 5-1/2 11 7-1/2 3/4 3/8 37 4 6-1/2 9 15/16 1/2 59 li' '4i io- 4 6-1/2 13 9 15/16 1/2 64 6 8 11 1 9/16 96 5 7-1/2 15 10 15/16 1/2 81 A-i 8 9 13.1/2 1-1/8 5/8 150 rtA� 6 8 16 11 1 9/16 105 8 9 18 13-1/2 1-1/8 5/8 165 10 11 22 16 1-3/16 3/4 270 12 12 24 19 1-1/4 13/16 380 Reducing Tee:Figure 812 Size(NPS) Weight(lbs) 2 6 83 Size(NPS) Weight(Ibs) 3 80 2-1/2 2-1/2 2 28 3 4 85 Size(NPS) Weight(Ibs) 2 3 33 6 91 6 6 342 • 2-12 3 35 3 86 6 220 `� 3 2 34 4 4 88 8 8 232 H. 1-1/2 32 6 94 10 262 '.•„�«. 3 2-1/2 35 4 91 10 3 218 4 56 6 5 5 102 4 225 2 4 50 2 86 10 5 235 4 NPS 2-1/2 49 2-1/2 90 6 240 6 NPS . 5 NPS 2-1/2 4 56 3 92 8 262 3 3 53 6 4 97 12 340 Read as: 8 298 6x5x4 4 4 59 5 105 8 1-1/2 50 8 142 12 340 2 51 6 140 6 310 4 2-1/2 56 4 8 146 10 8 320 3 57 5 8 149 10 340 6 88 4 125 72 12 365 _ 4 4 73 6 6 144 4 291 5 80 8 159 5 295 5 2-1/2 66 3 140 12 6 323 5 3 71 4 143 8 330 4 80 5 149 10 362 6 102 8 6 156 10 235 12 275 r. 114 vvww,lakesidesupply.com Lakeside Supply Company r . 2 to-94 l_6800 Pipe Fittings - - u w - r. *AISnn CAST IRON FLANGED FITTINGS CLASS 125, STANDARD Cross S1zQ A AA Flange Min.Flange Wall Weight Figure 821 (NPS) (in) (in) Diameter(in) Thickness(in) Thickness(in) (lbs) 2 4-1/2 9 6 5/8 5/16 28 2-1/2 5 10 7 11/16 5/16 39 ,:.11.. 3 5.1/2 11 7-1/2 3/4 3/8 48 � ° 4 6-1/2 13 9 15/16 1/2 82 1 5 7-1/2 15 10 15/16 1/2 105 6 8 16 11 1 9/16 135 8 9 18 13-1/2 1-1/8 5/8 210 10 11 22 16 1-3/16 3/4 330 12 12 24 19 1-1/4 13/16 470 •-A Al 4 A t Lateral Face to Center to Center to Flange Min.Flange Wall Figure 823 Size Face Face Face Diameter Thickness Thickenss Weight (NPS) D(in) E(in) F(in) (In) (in) (in) (Ibs) -'' 2 10-1/2 8 2.1/2 6 5/8 5/16 25 2-1/2 12 9-1/2 2-1/2 7 11/16 5/16 36 3 13 10 3 7-1/2 3/4 3/8 44 4 15 12 3 9 15/16 1/2 75 5 17 13-1/2 3-1/2 10 15/16 1/2 96 6 18 14-1/2 3-1/2 11 1 9/16 125 .... 8 22 17-1/2 4.1/2 13-1/2 1-1/8 5/8 210 !'I F u ___ F Trueura 8 Flange Min.Flange Wall Figure 10 Size A B Diameter Thickness Thickness Weight (NPS) (in) (in) (in) (in) (in) (Ibs) -.. 4 3 6-1/2 9 15/16 1/2 60 6 3-1/2 8 11 1 9/16 101 8 4-1/2 9 13-1/2 11/16 5/8 154 ea 6 A T s www.lakesidesupply.com 115 Pipe Fittings lakeside Supply Company 216-941-6800 /s�lr►!!11,= IRON FLANGES CLASS 125, STANDARD Blind Flange Pipe Size Diam.of Flange Min.Flange Wall Thick. Weight(Ibs) Cast Iron:Figure 1018 I(NPS) 0(NPS) Thickness Q(in) V(in) Cast Iron 10 x 16(NPS)and smaller 1 4-1/4 7/16 3/8 2.00 1-1/4 4-5/8 1/2 7/16 2.25 . 1-1/2 5 9/16 1/2 3.75 y;r 2 6 5/8 9/16 4.00 ' - 2-1/2 7 11/16 5/8 6.75 3 7-1/2 3/4 11/16 8.00 f"xc �10. 3-1/2 8-1/2 13/16 3/4 11.00 NW)F h I--� 4 9 15/16 7/8 14.00 5 10 15/16 7/8 18.00 6 11 1 15/16 23.00 12 x 9(NPS)and larger 8 13-1/2 1-1/8 1-1/16 40.00 10 16 1-3/16 1-1/8 59.00 12 19 1-1/4 13/16 88.00 Ilk 14 O.D. 21 1-3/8 718 115.00 16 O.D. 23-1/2 1-7/16 1 160.00 F 18 0.D. 25 1.9/16 1-1/16 190.00 t --` "'^- 200.D. 27-1/2 1-11/16 1-1/8 250.00 t-..Jr- ;'17>1`.„..JIo 24 O.D. 32 1-7/8 1-1/4 370.00 e 1 All standard blind flanges sizes 12 NPS(19 inch O.D.)and larger must be dished with inside radius equal to the port diameter. When ordering blind flanges always give outside diameter. H All Class 125 cast iron standard flanges have a flat face. Companion Flange Pipe Diam.of Min.Flange Min.Dlam. Min.Length Weight Cast Iron:Figure 1011 Size Flange Thickness of Hub Through Hub Malleable:Figure 1035 9 9 (Ibs) (NPS) 0(in) 0(in) X(in) Y(in) Cast Iron Malleable 3/4 3-7/8 7/16 1-3/4 5/8 1.50 - e . 1 4-1/4 7/16 1-15/16 11/16 1.75 1.1/4 4-5/8 1/2 2-5/16 13/16 2.00 - 1-1/2 5 9/16 2-9/16 7/8 2.25 2.25 Showing Hub 2 6 5/8 3-1/16 1 4.00 4.00 2-1/2 7 11/16 T 3-9/16 1-1/8 6.00 6.00 3 7-1/2 3/4 - 4-1/4 13/16 7.63 7.63 5f } ,. '- 3-1/2 8-1/2 13/18 4-13/16 1.1/4 9.00 - 4 9 15/16 5-5/16 1-5/16 11.75 11.75 Showing Plain 5 10 15/16 6-7/16 1-7/16 14.00 14.00 6 11 1 7-9/16 1-9/16 16.50 16.50 x 1 8 13-1/2 1-1/8 9-11/16 1-3/4 26.00 26.00 /. T10 16 1-3/16 11-15/16 1-15/16 37.75 - Y 12 19 1-1/4 14-1/16 2-3/16 50.50 - � 140.D. 21 1-3/8 15-5/8 2-1/4 80.00 - 160.D. 23-1/2 1-7/16 17-1/2 2-1/2 100.00 - 18 0.D. 25 1-9/16 19-5/8 2-11/16 106.00 - 20 O.D. 27-1/2 1-11/16 21-3/4 2-7/8 128.00 - 240.0. 32 1-7/8 26 3-1/4 202.00 - When ordering companion flanges always give outside diameter as well as nominal pipe size. 116 wwwjakesidesuppty.com Lakeside Supply Company 2 tb-94 �6&Oa Pipe Fittings o A r"► r 'c'kta 8,, ,,4 r tom...z Jr,. 'f ,v'\.T _. ,.... (1r), AIWIL IRON FLANGES CLASS 125, STANDARD Reducing Pipe Flange Min.Flange Min.Diam Min.Length Weight Companion Flange Size Diameter Thickness of Hub Thru Hub Cast Iron Cast iron:Figure 1016 (NPS) 0(in) 0(in) X(in) Y(in) (Ibs) 1-15/16 11/16 2.75A 1 5 9/16 1-114 2-5/16 13/16 2.50A 1 1-15/16 11/16 5.00A 1-1/4 6 5/8 2-5/16 13/16 4.75A 1-1/2 2-9/16 7/8 4.50A ..` 1-1/2 2-9/16 7/8 7.004 li 2 7 1-1/16 3-1/16 1 6.75A 1 1-15/16 13/16 9.00 1-1/2 7-1/2 3/4 2-9/16 7/8 8.75/. 2 3-1/16 1 8.50/. 2-1/2 3-9/16 1-1/8 8.00/. 3 8-1/2 1-3/16 4-1/4 1-3/16 10.00 I.---X---id 1.1/2 2-9/16 1 14.75A .; . �OtY 2 3-1/16 1 14.00A 3-9/16 1-1/8 13.504 h O 2.1/2 9 1-5/16 _ 3 4-1/4 1-3/16 12.754 3-1/2 4-13/16 1-1/4 12.00 3 4-1/4 1-3/16 17.00A To order reducing companion flanges, q 10 1-5/16 5-5/16 1-5/16 16.004 specify threaded or reduced size first, 1-1/2 2-9/16 1-1/16 27.00 then the outside diameter of desired flange.For instance,if a reducing flange 2 3-1/16 1-1/16 26.004 is required to connect a 5 NPS pipe to 2-1/2 11 1 3-9/16 1-1/8 25.00 an 8 NPS valve or fitting having a 3 4-1/4 1-3/16 23.004 13-1/2 Inch/345 O.D.flange,order q 5-5/16 1-5/16 21.00A 5 NPS x 13-1/2 inch reducing flange. 5 6-7/16 1-7/16 19.00A /.Stock galvanized 2 3-1/16 1-3/16 44.00 3 4-1/4 1-3/16 40.00 4 13-1/2 1-1/8 5-5/16 1-5/16 37.00A 5 6-7/16 1-7/16 34.00 6 7-9/16 1-9/16 31.00A 7-9/16 1-9/16 53.00A 6 16 1-3/16 8 9-11/16 1-3/4 50.00/. 6 7-9/16 1-9/16 88.00 8 19 1-1/4 9-11/16 1-3/4 81.00 10 11-15/16 1-15/16 72.00 r vg . n ,...,. . r' sac,.i r+ -- .. p41 i * 0. .- ..,�.... lotariL^WL^...au.a.tl�v.r rw.' R `' f �' dF ° d Vf , :s"i, �i,"8I Ie, , :110111 4 ff. i 7 "... 1 s s §, ar ins -- + v ptt p a Ms. e ' �;-x9w s ,nT 4: '' p,ryS 9�4Si !f ��4( 0.i+.. #+"`q: E b F C,. 'd)? tic ="c 111:11 h yam. ga je..f`. ki, tl ) 'I TI,1p h a�k9 N as l'"1. ,7... w ti �rT ; , 'gym.! p.,,.. .;'' ^�`v ,.., z" Sc - _.-m..7,.\--.Ck-;Sa":.a i. Ay . a . v i9a n�. 'I ,:: k ':.'- —grow .- ,w,.M .,,.d.4 $ i ,.0 'k.,✓' M.. �.. Y. 1dIAr :r9 www.,lakesidesupply.com 117 !• Pipe Fittings Lakeside Supply Company 216-941-080.G flr:1111NIV1.4 IRON FLANGES CLASS 250, EXTRA HEAVY Companion Flange Pipe Flange Min.Flange Min.Hub Min.Length Min.Length Diam.of Weight Cast Iron:Figure 1025 Size Diameter Thickness Diameter Through of Threads Raised Face Case Iron (NPS) 0(in) 0(in) X(in) Hub-Y(in) T(in) W(in) (Ibs) 1-1/4 5-1/4 3/4 2-1/2 1 0.76 3-1/16 3.75 1-1/2 6-1/8 13/16 2-3/4 1-1/8 0.87 3-9/16 5.75 2 6-1/2 7/8 3-5/16 1-1/4 1.00 4-3/16 6.50 q"" ' � 2-1/2 7-1/2 1 3-15/16 1-7/16 1.14 4-15/16 9.50 -'- 3 8-1/4 1-1/8 4-5/8 1-9/16 1.20 5-11/16 12.33 3-1/2 9 1-3/16 5-1/4 1-5/8 1.25 6-5/16 16.00 4 10 1-1/4 5-3/4 1-3/4 1.30 6-15/16 20.00 X .I 5 11 1-3/8 7 1-7/8 1.41 8-5/16 24.00 / ti 6 12-1/2 1-7/16 8-1/8 1-15/16 1.51 9-11/16 32.00 --.-- T -. �Q iY 8 15 1-5/8 10-1/4 2-3/16 1.71 11.15/i6 51.00 W_,.. 10 17-1/2 1-7/8 12-5/8 2-3/8 1.92 14-1/16 77.00 O 12 20-1/2 2 14-3/4 2-9/16 2.12 16-7/16 103.00 Reducing Companion Flange Pipe Flange Min.Flange Min.Length Min.Length Diam.of Weight Cast Iron Size Diameter Thickness Through of Threads Raised Face Case Iron Figure 1030 (NPS) 0(in) 0(in) Hub-Y(in) T(in) W(in) (Ibs) �. ,,,• 2 8-1/4 1-1/8 1-1/4 1.00 5-11/16 14.25 `'`• : Mx'2 2-1/2 8-1/4 1-1/8 1-7/16 1.14 5.11/16 13.50` 3 10 1-1/4 1-9/16 1.20 6-15/16 22.75 r... 4 11 1-38 1-3/4 1.30 8-5/16 30.00 4 12-1/2 1-7/16 1-3/4 1.30 9-11/16 39.50 h.-X -1 5 12-1/2 1-7/16 1-7/8 1.41 9-11/16 36.00 _ 6 15 1-5/8 1-15/16 1.51 11-15/16 59.00 Ill IN II O 1Y I' W I 0 - Blind Flange Pipe Flange Diam.of Min.Flange Min.Metal Weight Cast iron Size Diam. Port Thickness Thickness Cast Iron Figure 1021 (NPS) 0(in) I(in) 0(in) V(in) (lbs) 1 4-7/8 1 11/16 .... 4.0 8 x 15 and smaller 1-1/2 6-1/8 1-1/2 13/16 .... 5.25 _ 2 6-1/2 2 7/8 .... 7.00 L.- 1, I I IQ 2-1/2 7-1/2 2-1/2 1 .... 11.00 H �-i I... -..._ 3 8-1/4 3 1-1/8 .... 14.00 W 3-1/2 9 3-1/2 1-3/16 .... 19.00 Q- 4 10 4 1-1/4 .... 23.00 V 5 11 5 1-3/8 .... 31.00 1 .} 6 12-1/2 6 1-7/16 .... 42.00 ...1., .,. -t .__IiQ 8 15 8 1-5/8 .... 70.00 I- 10 17-1/2 10 1-7/8 15/16 1 104.00 ,(•"� - 12 20-1/2 12 2 145.00 • 10 x 171/2 and larger -.P . ilk-. _. _t-i* ': ./.., * "14. i =: ...4 . 4, )M'i 1*,.X.11,F, CIO'`" .. .` >:, n -{" _ n.-.!_.b.1N7,"._. 1 18 www.lakesidesupply.com lakeside Supply company Pie Fittings .. '\ . . . (! 14 ' CAST IRON FLANGED FITTINGS CLASS 250, EXTRA HEAVY Concentric Reducer Size G Weight Figure 855 (NPS) (in) (Ibs) 2-1/2 2 5-1/2 24 2 25 ittativ,` 3 2-1/2 6 29 2 36 4 2-1/2 7 40 P 3 44 ill 2-1/2 50 5 3 8 54 G 4 63 I`— 2-1/2 63 6 3 9 67 4 77 5 85 4 105 8 5 11 115 6 130 0 6 2 170 8 190 90°Elbows Figure 831 Size A Flange Flange Diam.of Raised Wall Thickness Weight (NPS) (in) Diameter(in) Thickness(in) Face(in) of Body(in) (Ibs) 2 5 6.1/2 7/8 4-3/16 7/16 20 ) 2-1/2 5-1/2 7-1/2 1 4-15/16 1/2 30 , rrr 3 6 8-1/4 1-1/8 5-11/16 9/16 40 , 4 7 10 1-1/4 6-15/16 5/8 65 ilk , 5 8 11 1-3/8 8-5/16 11/16 87 6 8-1/2 12-1/2 1-7/16 9-11/16 3/4 115 A 8 10 15 1-5/8 11-15/16 13/16 185 '� 10 11-1/2 17-1/2 1-7/8 14-1/16 15/16 290 12 13 20-1/2 2 16-7/16 1 410 A 1 Lakeside can also furnish a full line of cast steel flanged pipe fittings. Virtually any flanged fitting configuration produced in cast iron is also made in cast steel. 150#, 300#, and higher rated fittings are readily available. Please contact us for a price and availabilty proposal. wwwtlke4iciesupy.CeM 119 Pipe Fittings Lakeside Supply company 21 o-941-6800 (� )ANVIL" CAST IRON FLANGED FITTINGS CLASS 250, EXTRA HEAVY Elbows Size C Flange Flange Diam.of Raised Wall Thickness Weight Figure 932 (NPS) (in) Diameter(in) Thickness(in) Face(in) of Body(min)(in) (Ibs) 2 3 6-1/2 7/8 4-3/16 7/16 18 2-1/2 3-1/2 7-1/2 1 4-15/16 1/2 28 3 3-1/2 8-1/4 1-1/8 5-11/16 9/16 35 4 4-1/2 10 1-1/4 6-15/16 5/8 58 rF 5 5 11 1-1/4 8-5/16 1-1/16 76 �T"' AM* 6 5-1/2 12-1/2 1-7/16 9-11/16 3/4 105 8 6 15 1-5/8 11-15/16 1-3/16 155 Gr� 10 7 17-1/2 1-7/8 14-1/16 1-5/16 240 12 8 20-1/2 2 16-7/16 1 340 C Taper Reducing Elbow Size A Weight Tee,Reducing on Size Reducing Weight Figure 833 (NPS) (in) (Ibs) Run oree 942 Outlet (NPS) (Ibs) A, 4 3 7 52 3 3 2-1/2 55 , rr ( 2-1/2 48 --_--- 2 50 if 4 78 2 77 5 3 8 65 LT, 4 4 2-1/2 83 Jr-r'solo 6 5 8-1/2 100 b i r 3 84 4 93 I- 5 5 4 125 /}-' 8 — 6 10 155 kr` 6 6 3 148 5 100 +, 4 160 10 8 11-1/2 240 In describing tees,the run 8 8 4 229 6 210 is first named,then the 6 257 A outlet,thus: 6 369 10 10 8 376 Dimensions for reducing tees for sizes listed 16 NPS and smaller have same center to face dimension as straight size fittings corresponding to the largest opening. Dimensions of sizes not listed furnished on request. Straight Tees Min. Diam.of Min.Wall Figure 841 Min.Inside Flange Flange Raised Thickness Size Diam.of Fitting J HH Diam. Thickness Face of Body Weight (NPS) (in) (In) (in) (in) (in) (in) (in) (Ibs) 2 2 5 10 6-1/2 7/8 4-3/16 7/16 32 2-1/2 2-1/2 5-1/2 11 7-1/2 1 4-15/16 1/2 46 3 3 6 12 8-1/4 1-1/8 5-11/16 9/16 58 4 4 7 14 10 1-1/4 6-15/16 5/8 99 5 5 8 16 11 1-3/8 8-5/16 11/16 135 6 6 8-1/2 17 12-1/2 1-7/16 9-11/16 3/4 180 8 8 10 20 15 1-5/8 11-15/16 13/16 280 J - 10 10 11-1/2 23 17-1/2 1-7/8 14-1/16 15/16 430 12 12 13 26 20-1/2 2 16-7/16 1 620 H ti f , 07" - --- 74.ilr ir7r77 t i,+.7::77, . 7 WO 4r3(0„v.,;(851 .40..P .. ,-)-.. 120 www.lakesidesupply.com Victaulic® Grooved End Fittings ��t iuirc, 07.01 • 11111 No.20 Tee No. 10 Elbow 1.0 PRODUCT DESCRIPTION Available Sizes • 3/4—60"/DN20— DN1500 Maximum Working Pressure • Pressure ratings for Victaulic standard fittings conform to the ratings of Victaulic Style 177N couplings(refer to publication 06.24 for more information). Application • Connects pipe, provides change in direction and adapts sizes or components • Supplied with Victaulic OGS grooves • Exclusively for use with Victaulic couplings, valves, accessories and pipe which feature ends formed with the Victaulic OGS groove profile Pipe Materials • Carbon steel or stainless steel NOTE • These fittings are not intended for use with Victaulic plain end couplings.Intended for use only in grooved piping systems.When connecting wafer or lug type butterfly valves directly to Victaulic fittings using Style 741 or Style 743 flange adapters,be sure to check disc clearance dimensions with I.D.dimension of fitting. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. �Ct9UliGr 1 victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) Other Fitting Styles AGS-Advanced Groove System from 14—607DN350—0N1500 Ductile Iron for AWWA size pipe Publication 20.05 Publication 23.05 Stainless Steel Publication 17.16 XL fittings for abrasive services Publication 07.07 Galvanized Publication 07.01 for Original Groove Fittings Publication 20.05 for AGS Fittings Aluminum Publication 21.03 911F1 Extra Heavy EndSeal "ES" 111N Publication 07.03 Shouldered Ends Publication 07.06 Copper Publication 22.04 Plain End Publication 14.04 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 2 4atauiicr victaulic.com • . 2.0 CERTIFICATION/LISTINGS c 4t as ® LPCB [VdS, urrrn NOTES • When supplied as"hot dip galvanized"the following fittings are UL Classified in accordance with ANSI/NSF 61 and for use on cold+86°F/+30°C potable water service and ANSI/NSF 372:No.10 90°Elbow,No.11 45°Elbow,No.12 221°Elbow,No.13 11 Vaa°Elbow,No.100 90°Long Radius Elbow,No.110 45°Long Radius Elbow,No.20 Tee,No,25 Tee with Grooved Branch,No.30 45°Lateral,No.60 Cap,No.50 Concentric Reducers,No.51 Eccentric Reducers. • The following Victaulic fittings are VdS approved:No.10 90°Elbow,No.11 45°Elbow,No.20 Tee and No.60 Cap. • The following Victaulic fittings are LPCB approved:No.10 90°Elbow,No.11 45°Elbow,No.12 22' Elbow,No.13 11 Ya°Elbow,No.3045°Lateral,No.30-R Reducing Lateral,No.100 Long Radius Elbow,No.110 Long Radius Elbow,No.20 Tee,No.35 Cross,No.60 Cap,No.25 Reducing Tee,No.33 True Wye,No.50 Concentric Reducer,No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. • The following Victaulic fittings are FM approved:No.10 90°Elbow,No.11 45°Elbow,No.12 22' Elbow,No.13 111/2°Elbow,No.30 45°Lateral,No.100 Long Radius Elbow,No.20 Tee,No.35 Cross,No.60 Cap,No.25 Reducing Tee and No.50 Concentric Reducer. 3.0 SPECIFICATIONS - MATERIAL Fitting: (specify choice) j Standard: Ductile iron conforming to ASTM A536, Grade 65-45-12. ❑ Optional: Segmentally welded steel as shown under nipples Nipples: (specify choice) ❑ 3/a-4'/DN20- DN100: Carbon steel, Schedule 40, conforming to ASTM A53, Type F ❑ 5-6"/DN125- DN150: Carbon steel, Schedule 40, conforming to ASTM A53, Type E or S, Gr. B ❑ 8- 12'/DN200- DN300: Carbon steel, Schedule 30 or 40, conforming to ASTM A53, Type E or S, Gr. B Flanged Adapter Nipples: (specify choice) ❑ Class 125 Flange: Cast iron conforming to ANSI B16.1 ❑ Class 150 Flange: Carbon steel conforming to ANSI B16.5, raised or flat face ❑ Class 300 Flange: Carbon steel conforming to ANSI B16.5, raised or flat face Fitting Coating: (specify choice) ❑ Standard: Orange enamel ❑ Optional: Hot dip galvanized and others.Some fittings supplied electroplated as standard-see product specifications Flanged Adapter Nipple Coating: (specify choice) ❑ Standard: None (Unfinished) ❑ Optional: Orange enamel, hot dip galvanized and others • • 07.01 1449 Rev AG Updated 09/2021 ®2021 Viclaulic Company.All rights reserved. victaulic.com 3 �ctaulic' victaulic.com • 4.0 DIMENSIONS Elbows No. 10 90° Elbow No. 11 45° Elbow .-c to e No. 12 221/2° Elbow No. 13 11 /4 Elbow ctotviII c o No. 100 90° Long all Radius Elbow r etnt 4_ No. 11045° Long o o e'e T- E Radius Elbow L. Standard and GSNK No. 100 No. 110 No. 10 No. 11 No. 12 No. 13 90°Long Radius 45°Long Radius Size 90°Elbow 45°Elbow 22 r/z°Elbow 11 r/a°Elbow Elbow Elbow Actual Approx. Approx. Approx. Approx. Approx. Approx. Outside Wgt. Wgt. Wgt. Wgt. Wgt. Wgt. Nominal Diameter C to E (Each) C to E (Each) C to E (Each) C to E (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb inches lb inches lb inches lb inches lb DN mm mm kg mm kg mm kg mm kg mm kg mm kg 'A 1.050 2.25 0.5 1.50 0.5 1.63(sw) _ 1.38(sw) _ 2.50(sw) 0.4 1.88(sw) 0.3 DN20 26.9 57 0.2 38 0.2 41 35 64 0.2 48 0.1 1 1.315 2.25 0.6 1.75 0.6 3.25' 0.6 1.38(sw) 0.3 2.88(sw) 0.6 2.25(sw) 0.5 DN25 33.7 57 0.3 44 0.3 83 0.3 35 0.1 73 0.3 57 0.2 1 Va 1.660 2.75 1.0 1.75 0.9 1.75 0.8 1.38(sw) 0.5 3.25(sw) 1.1 2.38(sw) 0.7 DN32 42.4 70 0.5 44 0.4 44 0.4 35 0.2 83 0.5 60 0.3 1'/z 1.900 2.75 1.2 1.75 0.9 1.75 0.8 1.38(sw) 0.5 3.63(sw) 2.2 2.50(sw) 1.3 DN40 48.3 70 0.5 44 0.4 44 0.4 35 0.2 92 1.0 64 0.6 2 2.375 3.25 1.8 2.00 1.3 1.88 1.2 1.38 1.0 4.38 2.5 2.75 1.8 DNSO 60.3 83 0.8 51 0.6 48 0.5 ' 35 0.5 111 1.1 70 0.8 21/2 2.875 3.75 3.2 2.25 2.2 4.00' 2.3 1.50 1.1 5.13 3.4 3.00 2.8 73.0 95 1.5 57 1.0 102 1.0 38 0.5 130 1.5 76 1.3 3.000 3.75 3.7 2.25 3.4 2.25 - 1.50 DN65 76.1 95 1.7 57 1.5 57 38 3 3.500 4.25 4.5 2.50 3.1 4.50' 3.1 1.50 2.1 5.88 6.0 3.38 4.9 DN80 88.9 108 2.0 64 1.4 114 1.4 38 1.0 149 2.7 86 2.2 3'/z 4.000 4.50 5.6 2.75 4.3 2.50(sw) 4.0 1.75(sw) 2.7 _ _ _ DN90 101.6 114 2.5 70 2.0 64 1.8 44 1.2 _ 4 4.500 5.00 7.1 3.00 5.6 2.88 5.6 1.75 3.6 7.50 12.3 4.00 7.3 DN100 114.3 127 3.2 76 2.5 73 2.5 44 1.6 191 5.6 102 3.3 4.250 5.00 11.0 3.00 5.6 108.0 127 5.0 76 2.5 - - _ 5.000 5.25(sw) 10.0 3.13(awl 6.0 3.50(sw) 6.6 1.88(sw) 4.2 127.0 133 4.5 79 2.7 89 3.0 48 1.9 5 5.563 5.50 11.7 3.25 8.3 2.88(sw) 7.8 2.00(sw) 5.0 9.25(sw) 18.0 4.88(sw) 14.8 141.3 140 5.3 83 3.8 73 3.5 51 2.2 235 8.2 124 6.7 5.250 5.50 11.7 3.25 8.3 _ 133.0 140 5.3 83 3.8 5.500 5.50 11.7 3.25 8.3 2.88 _ 2.00 DN125 139.7 140 5.3 83 3.8 73 51 6 6.625 6.50 17.2 3.50 10.8 6.25' 12.2 2.00 7.0 10.75 30.4 5.50 17.4 DN150 168.3 165 7.8 89 4.9 159 5.5 51 3.2 273 13.8 140 7.9 6.250 6.50 18.6 3.50 10.8 _ _ _ _ 159.0 165 8.4 89 4.9 6.500 6.50 15.5 3.50 9.8 3.13 11.4 2.00 7.4 10.75(sw) 29.0 5.50(sw) 19.0 165.1 165 7.0 89 4.4 79 5.2 51 3.4 273 13.2 140 8.6 ' Gooseneck design,end-to-end dimension finings in Ibis size,contact your nearest Victaulic sales representative. (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded NOTE • All fillings are ductile iron unless otherwise noted with an(sw)or(s)_ • • 07.01 1449 Rev AG Updated 09/2021 ©2021 Victaulie Company.All rights reserved. victaulic.com 4 ✓otauIic victaulic.com • 4.0 DIMENSIONS (CONTINUED) Elbows No. 10 90° Elbow No. 11 45° Elbow --ctoe No. 12 221/2° Elbow 1 No. 13 111/4°° Elbow i•-ct°E.I I CtoE Radius us 90 Long i �1 ctoE' l� 0111 � Radius Elbow E i t croe . L No. 110 45° Long of \� ct EM - Radius Elbow } �� IDS =_ • Standard and GSNK -_l _.. _..... .. .No. 100 No. 110 No. 10 No. 11 No. 12 j No. 13 90°Long Radius 45°Long Radius Size 90°Elbow 45°Elbow 221/2°Elbow 111/4°Elbow Elbow Elbow Actual Approx. Approx. Approx. ,Approx. Approx. Approx. Outside Wgt. Wgt. I Wgt. Wgt. Wgt. Wgt. Nominal Diameter C to E (Each) C to E (Each) ! C to E ! Each C to E I (Each) C to E (Each) C to E (Each) inches inches inches lb inches lb ' inches lb ' inches ' lb inches lb inches ' lb DN mm mm kg mm kg mm kg mm kg mm kg mm kg ' 8 8.625 7.75 29.9 4.25 20.4 7.75' 20.0 2.00 10.1 14.25 66.0 7.25 36.0 DN200 219.1 197 13.6 108 9.3 197 9.1 51 4.6 362 30.0 184 16.3 10 10.750 9.00 63.3 4.75 37.5 4.38(sw) 30.0 2,13 11.8 15.00 107.0 6.25 57.0 DN250 _ 273.0 229 28.7 121 17.0 111 13.6 54 5.3 381 48.5 159 25.9 12 12.750 10.00 74.0 5.25 66.7 4.88(sw). 40.0 2.25 29.3 18.00 156.0 7.50 90.0 DN300 323.9 254 33.6 133 30.3 124 18.1 57 13.3 457 70.8 191 40.8 142 14.000 14.00 136.0 5.75 65.0 5.00(sw) 46.0 3.50(sw) 32.0 21.00(s) 164.0 8.75 82.0 DN350 355.6 356 ' 61.7 146 29.5 127 20.9 89 14.5 533 74.4 222 37.2 14.843 14.84 149.3 6.13 82.0 _ 377.0 377 67.7 156 37.2 162 16.000 16.00 171.0 6.63 88.0 5.00(sw) 58.0 4.00(sw) 42.0 24.00(s) 210.0 10.00(s) 100.0 DN400 406.5 _ 406 77.6 168 39.3 127 26.3 102 19.1 610 95.3 254 45.4 16.773 • 16.75 198.6 7.00 101,3 426.0 425 90.1 178 45.9 182 18.000 18.00 228.0 7.50 108.0 5.50(sw) 65.0 4.50(sw) 53.2 27.00(s) 273.0 11.25(s) 135.0 DN450 457.2 457 103,4 190 50.0 140 29.5 144 24.1 686 123.8 286 j 61.2 18.898 18.88 291.0 7.83 141.7 _ _ _ _ _ _ _ ,I 480.0 480 132.0 200 64.3 202 20.000 20.00 298.0 8.25 138.0 6.00(sw) 78.6 5.00(sw) 65.0 30.00(s) 343.0 12.50(s) 174.0 DN500 508.0 508 135.2 210 62.6 152 36.0 127 29.5 762 155.6 318 78.9 20.866 20.88 355.0 8.63 179.0 _ _ _ _ _ 530.0 530 161.0 219 81.2 242 24.000 24.00 438.0 10.00 221.0 7.00(sw) 140.0 6.00(sw) 60.0 36.00(s) 516.0 15.00(s) 251.0 DN600 609.6 610 198.7 254 100.2 178 63.5 152 27.2 914 234.1 381 113.9 I 24.803 24.80 545.0 10.25 255.2 630.0 630 247.2 261 115.7 For AGS fitting information,see p ol,cater,20.03 14-60 ------- DN350-DN1500 A GS" V Gooseneck design,end-to-end dimension fittings in this size,contact your nearest Victaulic sales representative. 2 For 147DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in This size, contact your nearest Victaulic sales representative. (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded NOTE • All fittings are ductile iron unless otherwise noted with an(sw)or(s). • • 07.01 1449 Rev AG Updated 09/2021 0 2021 Victaulic Company.All rights reserved. victaulic.com 5 �ctaultc* victaulic.com 4.1 DIMENSIONS Reducing Base Support Elbow No. R-1OG Grv. x Grv. r-ctoE-i 1 �cc°, E»e No. R-10F Grv. x Flange 1. 1)-vi i B Dia. B Dia. Size Reducing Base Support Elbow Approx.Weight Each 1 Nominal C to E H B Diameter Grv.x Grv. Grv.x Flange Inches inches inches inches lb lb DN mm mm mm kg ', kg 6 4 9.00 1.25 1.50 19.0 33.0 • DN15D x DN100 229 32 38 8.6 15.0 ' 5 9.00 1.50 1.50 23.0 38.0 229 38 38 10.4 17.2 8 6 10.50 2.13 1.50 33.0 ---------- 52.0 DN200 x DN150 267 24 38 15.0 23.6 10 8 12.00 2.40 1.50 61.0 88.0 DN250 x DN200 305 61 38 27.7 39.9 • 4.2 DIMENSIONS • • Adapter Elbow • • No. 18 90°Adapter Elbow No. 19 45°Adapter Elbow l` GE 7 uo GE r\ C to TIE C o L TE I No. 18 No. 19 Size T90°Adapter Elbow 45°Adapter Elbow • Actual 1 Approximate Approx. • Outside Weight Weight Nominal I Diameter C to GE C to TE (Each) C to GE C to TE (Each) inches inches inches inches ' lb inches inches lb DN mm mm mm kg mm mm kg 3/4 1.050 • 2.25 2.25 0.5 1.50 1.50 0.5 DN20 26.9 57 57 0.2 38 38 0.2 1 1.315 2.25 2.25 0.5 _ _ _ DN25 33.7 • 57 57 0.2 1 V. 1.660 ---r 2.75 2.75 0.9 _ _ _ DN32 42.4 l 70 70 0.4 1 2 1.900 2.75 2.75 1,1 1.75 1.75 0.9 DN40 48.3 70 70 0.5 44 44 0.4 2 2.375 3.25 4.25 2.5 DN50 60.3 83 108 1.1 21/2 2.875 3.75 3.75 3.0 2.25 2.25 2.3 73.0 95 95 1.4 57 57 1.0 3 3.500 4.25 6.00 5.8 2.50 4.25 5.0 DN80 88.9 108 152 2.6 64 108 2.3 31/5 4.000 4.50 6.25 8.0 5.25 5.25 8.8 DN90 101.6 114 159 3.6 133 133 • 4.0 I 6 6.625 6.50 6.50 17.6 3.50 3.50 12.7 ' DN150 168.3 165 165 __, 8.0 89 89 5.8 NOTE • Available with British Standard Pipe Threads,specify"BSP"clearly on order. • • 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctaulrc' uictaulic.com 4.3 DIMENSIONS Tees, Crosses and True Wyes �Cto C-� N � C/CO LE �Cto C GE -5 1!1 r \ ill! � I C I \ _ I I m II 1 I I + CSE Cro TE No.20 No.35 No.33 No. 29M Size Tee Cross(sw) True Wye(sw) Tee with Threaded Branch Actual Approx. Approx. Approx. Approx. Outside Weight Weight Weight Weight Nominal Dimeter C to E (Each) C to E (Each) C to LE C to SE (Each) C to GE C to TE (Each) inches inches inches lb inches lb inches inches lb inches inches lb DN mm mm kg mm kg mm mm kg mm mm kg • 3/4 1.050 2.25 0.6 2.25 0.9 2.25 2.00 0.7 2.25 2.25(sw) 0.6 DN20 26.9 57 0.3 57 0.4 57 51 0.3 57 57 0.3 . 1 1.315 2.25 1.0 2.25 1.3 2.25 2.25 1,1 ' 2.25 2.25 1.0 DN25 33.7 57 0.5 57 0.6 57 57 0.5 57 57 0.5 1 V4 1.660 2.75 1.5 2.75 2.1 2.75 2.50 1.5 2.75 2.75 1.5 DN32 42.4 70 0.7 70 1.0 70 64 0.7 70 70 0.7 1/ 1.900 2.75 2.0 2.75 2.5 2.75 2.75 1.8 2.75 2.75 2.0 DN40 48.3 70 0.9 70 1.1 70 70 0.8 70 70 0.9 • 2 2.375 3.25 3.0 3.25 3.8 3.25 2.75 2.5 3.25 4.25 3.0 • DN50 60.3 83 1.4 83 '.._ 1.7 83 70 1.1 83 108 1.4 • 23/4 2.875 3.75 4.3 3.75 6.1 3.75 3.00 4.3 3.75 3.75 4.3 73.0 95 2.0 95 2.8 95 76 2.0 95 95 2.0 • 3.000 3.75 5.2 - - - - 3.75 3.75(sw) 5.2 DN65 76.1 95 2.4 95 95 2.4 • 3 3.500 4.25 6.8 4.25 10.5 4.25 3.25 6.1 4.25 6.00 6.8 DN80 88.9 108 3.0 108 4.8 108 83 2.8 i 108 152 3.1 31/2 4.000 4.50(sw) 7.9 4.50 11.5 4.50 3.50 9.6 4.50 4.50(sw) 7.9 • DN90 101.6 114 3.6 114 5.2 114 89 4.4 114 114 3.6 4.250 5.00 15.5 _ _ 5.00 5.00(sw) 15.5 108.0 127 7.0 127 127 7.0 4 4.500 5.00 11.9 5.00 15.8 5.00 3.75 9.8 5.00 7.25 11.9 DN100 114.3 127 5.4 127 7.2 127 95 4.4 _ 127 184 5.4 5.000 5.25(sw) 15.0 5.25 18.5 5.25 5.25(sw) 15.0 127.0 133 6.8 133 8.4 _ 133 133 6.8 5.250 5.50 17.8 _ 5.50 5.50(sw) 17.8 • 133.0 140 8.1 _ 140 140 8.1 5.500 5.50 17.8 _ _ _ -5.50 5.50(sw) 17.8 DN125 139.7 140 8.1 140 140 8.1 5 5.563 5.50 17.8 5.50 20.0 5.50 4.00 15.0 5.50 5.50(sw) 17.8 141.3 140 8.1 140 9.1 140 102 6.8 140 140 8.1 6.250 6.50 27.1 6.50 6.50(sw) 27.1 159.0 165 12.3 165 165 12.3 6.500 6.50 22.0 6.50 28.0 _ _ 1- _ 6.50 6.50(sw) 22.0 165.1 165 10.0 165 12.7 ,_ .. 165 165 10.0 6 6.625 6.50 25.7 6.50 28.0 6.50 4.50 22.3 i 6.50 6.50(sw) 25.7 DN150 168.3 165 11.7 165 12.7 165 114 10.1 ii 165 165 11.7 8 8.625 7.75 47.6 7.75 48.0 7.75 6.00 36.0 7.75 7.75 47.6 DN200 219.1 197 21.6 197 21.8 197 152 16.3 197 197 21.6 10 10.750 9.00 99.0 9.00 121.5 9.00 6.50 69.9 9.00 9.00 99.0 DN250 273.0 229 44.9 229 55.1 229 155 31.7 229 229 44.9 12 12.750 10.00 133.0 10.00 110.0 10.00 7.00 80.0 10.00 10.00 133.0 DN300 323.9 254 60.3 254 49.9 254 178 36.3 254 254 60.3 (s)=Carbon Steel Direct Rol'Groove(OGS) (sal=Carbon Steel Segmentally Welded NOTE • All fittings are ductile iron unless otherwise noted with an(sw)or(s). • • 07.01 1449 Rev AG Updated 09/2021 O 2021 Vlctaulic Company.All rights reserved. victaulic.com 7 ✓ctaul.c' • victaulic.com • • 4.3 DIMENSIONS (CONTINUED) Tees, Crosses and True Wyes ,«C tot] rCtOE+ �� Cto(� C to lip! to II �� II � � ��I II �� "o cto TE SE y No.20 No.35 No.33 No.29M Size Tee Cross(sw) True Wye(sw) Tee with Threaded Branch Actual Approx. Approx. Approx. j Approx. Outside Weight i Weight Weight j Weight Nominal Dimeter C to E (Each) C to E J (Each) C to LE C to SE (Each) J C to GE C to TE (Each) inches inches inches 11 lb Inches lb inches inches lb inches ' inches lb DN mm mm kg mm kg mm mm kg mm mm kg 14' 14.000 11.00(sW) 145.0 ' 11.00 198.0 11.00 7.50 134.2 _ - DN350 355.6 279 ' 65.8 279 89.8 279 191 60.8 377.0 11.50 145.0 292 65.8 16' 16.000 12.00(sw) 186.0 12.00 250.0 12.00 8.00 167.0 _ DN400 406.4 305 84.4 305 1134 305 203 75.7 - 426.0 13.00 186.0 _ 300 84.4 18' 18.000 15.50(sw) 260.0 15.50 350.0 15.50 8.50 234.0 _ _ _ DN450 457.0 394 117.9 394 158.8 394 216 106.1 480.0 14.63 256.0 372 116.1 20' 20.000 17.25(sw) 336.0 17.25 452.0 17.25 9.00 281.0 _ DN500 508.0 438 152.4 438 205.0 438 229 127.5 530.0 15.38(sw) 339.0 - -391 153.8 24' 24.000 20.00(sw) 592.0 20.00 795.0 ! 20.00 10.00 523.0 _ _ _ DN600 610.0 508 268.5 508 360.6 508 254 237.2 630.0 17.38(sw) 473.0 i 441. J._ 214.5 1 I _. 14-60 For AGS fitting information, see DN350-DN 1 S00I, AGS- 2 For 1471DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For r.nr arc availa cdity of r❑t g'oove Pitting;in HI, size,contact your nearest Victaulic sales representative. (s)=Carbon Steel Direct Roll Groove(0GS) (sw)=Carbon Steel Segmentally Welded NOTE • All fittings are ductile iron unless otherwise noted with an(sw)or(s). • • 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 8 ,ctaulia v ICtaU Ic.0 Oral 4.4 DIMENSIONS Reducing Tee No. 25 Grooved Branch ctoE i ctoE No. 29T Threaded Branch II�III Tc II II T c o li•CtoE wCto El E tE i 11,11 Co II II C No.25 No 29T to E Na.29T li 1 No.25 w/Thd. i Size Std. Branch Approx. No.25 No.29T ----- Weight 7 ._ No.29T -"" Nominal C to E C to E (Each) No.25 1 w/Thd. : inches inches inches lb Size Std. Branch Approx. i DN mm mm kg Weight 4 4 3/4 5.00(sw) 5.00(sw) 8.0 Nominal C to E C to E (Each) DN100 x DN100 x DN20 127 127 3.6 inches inches inches lb '. ' 1 5.00 5.00 7.8 DN mrn mm kg DN25 127 127 3.5 1 1 3/4 2.25(sw) 2.25(sw) 1.0 1 Y4 5.00(sw) 5.00(sw) 9.6 DN25 x DN25 x DN20 57 57 0,5 DN32 127 127 4.4 1 V4 1'/a 1 2.75(sw) 2.75(sw) 1.3 1 Y: 5.00 5.00 10.2 DN32 x DN32 x DN25 70 70 0.6 DN40 127 127 4.6 1'h 1 Y 3'4 2.75(sw) 2.75(sw) 1.5 2 5.00 5.00 11.2 DN40 x DN40 x DN20 70 70 0.7 DN50_ 127 127 5.1 _- 1 2.75(sw) 2.75(sw) 1.5 2' 5.00 5.00 11.4 DN25 70 70 0.7 127 127 5.2 1 Y4 2,75(sw) 2.75(sw) 1.7 3 5.00 5.00 11.6 DN32 70 70 0.8 DN80 127 127 5.3 2 2 3/4 3.25 3.25 2.5 5 x 5 x 1 5.50(sw) 5.50(sw) 14.0 DN50 x DN50 x DN20 83 1 83 11 DN25 140 140 6.4 1 3,25 ' 3.25 2.7 1'h 5.50(sw) 5.50(sw) 14.3 _DN25 83 83 1.2 DN40 140j 140 6.5 _ 1 1 3.25(sw) 3.25(sw) 1.8 2 5.50(sw) 5.50(sw) 1 14.5 _DN32 83 83 0.8 ' DN50 140 140 6.6 1'k 3.25 3.25(sw) 3.0 21/2 5.50 5.50(sw) 15.2 DN40 83 83 1.4 140 140 6.9 2 9 x 2'h x 3/4 3.75(sw) 3.75(sw) 3,9 3 5.50 5.50(sw) 16.6 '.. DN20 95 95 1.8 '. DN80 140 140 7.5 - 1 3.75 3.75(sw) 3.8 4 5.50 5,50(sw) 16.7 _DN25 95 95 1.7 DN100 140 140 7.6 1 1/4 3.75 3.75 4.2 6 6 1 6.50(sw) 6.50(sw) 23.0 _DN32 95 95 1.7 DN15D x DN150 x DN25 165 ` 165 10.4 1 Ya 3.75 3.75 3.9 1'h 6.50(Sw) 1 6.50(Sw)- 24.0 DN40 95 95 1.8 DN40 1 165 165 10.9 1, _ 2 3.75 3.75(sw) 4.5 2 6.50 6.50 21.6 ' DN50 95 95 2.0 DN50 165 165 9.8 3 3 'A 4.25(sw) 4.25(sw) 5.7 21/2 6.50 6.50 21.4 DN80 x DN80 x _DN20 108 108 2.6 165 165 11.7 1 4.25 4.25 6.1 3 6.50 6.50 26.5 DN25 108 108 2.8 DN80 165 165 12.0 1 1/4 4.25 4.25 1 8.0 4 6.50 6.50 25.0 DN32 108 108 3.6 DN100 165 165 11.3 11/2 4.25 4.25(sw) 6.5 1 5 6.50 6.50 23.2 1, DN40 108 108 2.9 _ 165 165 10.5 2 4.25 4.25(sw) 6.2 61/2 x 61/2 x 3 6.50 6.50(sw) 24.0 DN50 108 108 2.8 DN80 165 165 10.9 2 V 4.25 4.25(sw) 6.4 4 6.50 6.50(sw) 25.0 L- 108 108 2.9 DN100 165 165 11.3 (s)=Carbon Steel Direct Roll Groove(OGS) (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded (sw)=Carbon Steel Segmentally Welded NOTE NOTE • Cast fitting available.Contact Victaulic for details. • Cast fitting available.Contact Victaulic for details. 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 9 'ctaulia victaulic.com • • 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 Grooved Branch ctoE+ wcto E� No. 29T Threaded Branch VII { II II c c �•Cto E+I I CtoEy ._ tE - � VII TC II II C C No.25 No.29 to __I to ro No.29T No.25 w/Thdhd. Size Std. Branch 1 Approx. No.25 No.29T Weight No.29T Nominal C to E C to E (Each) No.25 w/TM. inches inches j inches lb Size Std. Branch Approx. DN mm mm . kg Weight 12 12 1 10.00(sw) :...10.00(sw)i 77.0 Nominal C to E C to E (Each) x x DN300 DN300 DN25 254 254 34.9 inches inches inches lb 2 10.00 fsw) 10.00(sw) 80.0 ON mm mm kg DN5_0 254 254 36.3 8 8 1 1/2 7.75(sw) 7.75(sw) 33.0 2 Y2 10.00(sw) 10.00(sw) 78.0 DN200 x DN200 x 0N40 197 197 15.0 1 254 254 35.4 2 7.75(sw) 7.75(sw) 33.5 3 10.00(sw) 10.00(sw) 82.0 DN50 197 ' 197 15.2 DN80 254 254 37.2 2 Y2 7.75(sw) 17.75(sw) 39.0 4 10.00(sw) 10.00(sw) 80.0 197 - 197 17.7 DN100 254 254 36.3 3 7.75(sw) 7.75(sw) 33.6 5 10.00(sw) 10.00(sw) 75.0 DN80 . 197 197 15.2 254 254 34.0 4 7.75 7.75 41.8 6 10.00(sw) 10.00(sw) 75.0 DN100 197 197 19.0 DN150 254 254 34.0 5 7.75(sw) 7.75(sw) 34.0 8 10.00(sw) 10.00(sw) 80.0 197 197 15.4 DN200 254 254 36.3 6 7.75 7.75 42.3 10 10.00(sw) 10.00(sw) 84.0 _DN150 197 197 19.2 DN250 254 254 38.1 165.1 mm x x 7.75(sw) 7.75(sw) 48.0 142 14 4 11.00(sw) 11.00(sw) 102.0 197 197 21.8 DN350 DN350 0N100 279 279 46.3 10 10 1 1 9.00 9.00 62.0 6 11.00(sw) 11.00(sw) 108.2 ON250 x DN250 x DN40 1 229 229 28.1 DN150 279 279 49.1 2 i 9.00(sw) 9.00(sw) 62.0 8 11.00 11.00 112.0 DN50 229 229 28.1 0N200 279 279 50.8 _ 2 1/2 9.00(sw) 9.00(sw) 62.4 i 10 11.00 11.00 120.0 229 229 {. 28.3 DN250 279 279 54.4 3 9.00(sw) 9.00(sw) 60.0 • 12 11.00- . 11.00 129.1 '. DN80 229 229 27.2 DN300 279 279 58.6 4 9.00(sw) 9.00(sw) 61.0 162 16 4 12.00 12.00 130.0 DN100 229 229 27.7 DN400 x DN400 x DN100 305 305 59.0 5 9.00(sw) 9.00(sw) 52.0 6 12.00(sw) 12.00(sw) 133.5 229 229 23.6 DN150 305 305 60.6 6 9.00(sw) 9.00(sw) 59.0 8 12.00 E 12.00 145.0 DN150 229 229 26.8 DN200 305 305 65.8 8 9.00(sw) 9.00(sw) 64.7 10 12.00 1 2.00 149.5 DN200 229 229 29.3 DN250 305 305 67.8 12 12,00 12.00 154.0 7 (s)=Carbon Steel Direct Roll Groove(OGS) DN300 305 305 69.9 (swi=Carbon Steel Segmentally Welded 14 12.00(sw) _ 167.0 NOTE DN350 305 75.8 • Cast fitting available.Contact Victaulic for details. 2 For 14"/19N350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded NOTE • Cast fitting available.Contact Victaulic for details. • • 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 10 �ctaulicf victaulic.com 4.4 DIMENSIONS (CONTINUED) Reducing Tee No. 25 Grooved Branch �ctoE ctoE No. 29T Threaded Branch II,!' Tc II I' 14' c �Cto E-• IwCtoE-1 tE E MIMI111,111 1 II II c No.25 No.29T E o No.29T No.25 w/Thd. Size Std. Branch Approx. No.25 No.29T Weight No.29T i Nominal C to E C to E (Each) No.25 w/Thd. inches inches 1 inches lb Size ____... Std. _Branch Approx. DN mm mm kg Weight 24' 24 8 20.00 20.00 340.0 Nominal C to E C to E (Each) DN600 x DN600 X DN200 508 508 154.2 inches inches inches lb 10 20.00 20.00 343.9 DN mm mm i kg DN250 508 508 156.0 18' 18 4 15.50(sw)''.1550(sw) 194.0 12 20.00 20.00 352.8 DN450 x DN450 x DN100 394 394 88.0 DN300 508 508 160.0 6 15.50(sw) 15.50(sw) 200.0 14 20.00 _ 360.0 DN150 394 394 90.7 DN350 508 163.3 8 15.50(sw) 15.50(sw) 202.0 16 20.00 378.0- DN200 i 394 394 91.6 DN400 508 171.5 10 15.50 15.50 212.0 18 20.00 - 380.0 0N250 394 394 96.2 DN450 508 172.4 12 15.50 15.50 222.6 20 20.00 _ 373.0 DN300 394 394 101.0 DN500 508 169.2 14 15.50 _ 230.1 For AGS fitting information,see DN350 394 104.4 14-60 publication 20.05 16 15.50 247.6 DN350-1500 AGS" DN400 394 112.3 V 20' x 20 x 6 17.25 17.25 240.0 2 For 14/DN350 and larger roll grooved systems,Victaulic offers the DN500 DN500 DN150 438 438 108.9 Advanced Groove System(AGS).For pricing and availability of cut groove 8 17.25 17.25 244.0 fittings in this size,contact your nearest Victaulic sales representative. DN200 438 438 110.7 (s)=Carbon Steel Direct Roll Groove(OGS) 10 i 17.25 17.25 256.0 (sw)=Carbon Steel Segmentally Welded DN250 ,, 438 438 116.1 12 _ 17.25 17.25 264.0 NOTES • DN300 438 438 119.8 • No.29T Threaded Outlet Reducing Tees are supplied NPT and are 14 17.25 275.0 - available with British Standard threads.For British Standard specify DN350 438 124.7 "'BSP"clearly on order. 16 17.2 5 288,6 • All fittings are ductile iron unless otherwise noted with an(sw)or(s). DN400 438 130.9 • Cast fitting available.Contact Victaulic for details. 18 17.25 1 - 297.0 DN450 438 134.7 2 For 14'VDN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded NOTE • Cast fitting available.Contact Victaulic for details. • • 07.01 1449 Rev AG Updated 09/2021 ©2021 Victaulic Company.All rights reserved. YICtaUIIC.COm 11 'CtruIic' victaulic.com • 4.5 DIMENSIONS Bull Plug No. 61 l•—EtoE—•( D No.61 No.61 Size Bull Plug(s) Actual Approx. Outside Weight Nominal Diameter E to E (Each) inches inches inches lb DN mm mm kg 2 2.375 4.00 2.5 DN50 60.3 102 1.1 2 th 2.875 5.00 3.0 73.0 127 1.4 3 3.500 6.00 4.5 DN80 88.9 152 2.0 4 4.500 7.00 7.5 DN100 114.3 178 3.4 5 5.563 8.00 12.0 141.3 203 5.4 ' 6 6.625 10.00 17.0 DN150 i 168.5 254 7.7 (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded NOTES • Steel dish caps available through 247DN600,contact Victaulic. • No.61 Bull Plugs should be used in vacuum service with Style 72 or 750 couplings. • All fittings are ductile iron unless otherwise noted with an(sw)or Is). 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 12 'ctaulic victaulic.com • 4.6 DIMENSIONS 45° Lateral No. 30 Ito Ito LE LE E �� E4Ate. SE��5.i S /C. No.30 No.30 No.30 - I No.30 Size 45 Lateral Weight _ Size 45°Lateral Weight IY i Actual Actual Outside Approx. Outside Approx. Nominal Diameter C to LE 1 C to SE (Each) Nominal Diameter C to LE 1 C to SE (Each) inches inches inches inches lb Inches Inches inches inches lb DN mm mm mm kg DN mm mm mm kg 1 54 1.050 4.50(sw) 2.00(sw) • 1.0 6.500 ' 14.00(sw) 4.50(sw) ' 43.6 DN20 26.9 114 51 0.5 165.1 356 114 19.8 1 1.315 5.00(sw) 2.25(sw) 1.7 6 6.625 14.00(sw) 4.50(sw) 43.6 f DN2S 33.7 _ 127 57 0.8 DN150 168.3 356 114 49.8 1'/°_._ 1.660 5.75 2.50 2.5(d) 8 8.625 18.00(sw) 6.00(sw) 72.0 DN32 42A 146 64 1.1 DN200 219.1 457 152 32.7 1'/z 1.900 6,25(sw) 2.75(sw) 3.5 10 10.750 20.50(sw) 6.50(sw) 105.0 DN40 48.3 159 70 1.6 DN250 273.0 521 165 47.6 2 2.375 7.00(sw) 2.75(sw) , 5.0 12 12.750 23.00(sw) 7.00(sw) 165.0 DN50 60.3 178 70 2.3 _ DN300 323.9 584 178 74.8 21/5 2.875 7.75(sw) 3.00(sw) 9.0 14' 14.000 26.50(sw) 7.50(sw) 276.0 73.0 197 76 4.1 DN350 355.6 673 191 ' 125.2 1 3.000 8.50(sw) 3.25(sw) 11.0 16' 16.000 29.00(sw) 8.00(sw) 344.2 DN65 76.1 216 83 5.0 DN400 _ 406.4 737 203 - 156.1 3 3.500 8.50 3.25 11.7(d) 18' 18.000 32.00(sw) 8.50(sw) 429.0 DN80 88.9 216 83 5.4 DN450 457.0 813 216 194.6 3 1 4.000 10.00(sw) 3.50(sw) 17.8 20' 20.000 35.00(sw) 9.00(sw) 500.0 • DN90 101.6 254 89 8.1 DN500 508.0 889 229 226.8 • 4 4.500 10.50 3.75 22.2(d) 242 24.000 40.00(sw) 10.00(sw) 715.0 DN100 114.3 267 95 10.1 DN600 I 610.0 1016 254 324.3 5 5.563 12.50(sw) 4.00(sw) 21.8 1 ' I For AGS fitting information,see publica.., 20.(i5 141.3 318 102 9.9 I 14-60 (s)=Carbon Steel Direct Rol`Groove(OGS) DN350-DN15001 /4 GS- V (sw)=Carbon Steel Segmentally Welded 2 For 14/0N350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel Direct Roll Groove lOGS) (sw)=Carbon Steel Segmentally Welded NOTE • All fittings are ductile iron unless otherwise noted with an(sw)or(s). 07.01 1449 Rev AG Updated 09/2021 0 2021 Victaulic Company.All rights reserved. victaulic.com 13 .ctauloc' victaulic.com 4.7 DIMENSIONS 45° Reducing Lateral No. 30-R to I c I \- LE j • LI i i C o N, L C to �, C:` SL-�/ SL-f/ No.30-R No.30-R No 30-R No 30-R Size 45°Reducing Lateral Size 45°Reducing Lateral Approx. ! Approx. I Weight I ! Weight 1 Nominal C to LE C to SE j (Each) Nominal C to LE C to SE (Each) inches inches inches I lb inches inches inches lb DN mm mm I kg ON mm mm kg 3 3 2 8.50 ! 3.25 9.8 142 14 4 26.50 7.50 172.0 DN80 x DN80 x DN50 216 83 4.4 DN350 x DN350 x DN100 673 191 78.0 21/2 8.50 3.25 I 9.8 6 26.50 7.50 187.0 216 83 4.4 DN150 673 191 84.8 4 4 2 10.50 3.75 10.0 • 8 26.50 7.50 205.8 DN100 x DN100 x DNSO 267 95 4.5 DN200 673 191 93.4 2V2 10.50 3.75 10.0 10 26.20 7.50 235.0 267 95 4.5 i DN250 673 191 106.6 3 10.50 3.75 18.3 12 26.50 750 250.0 DN80 267 95 8.3 DN300 673 191 113.4 5 x 5 x 2 12.50 4.00 24.0 162 16 6 29.00 8.00 215.0 DN50 318 102 10.9 DN400 x DN400 x DN150 737 203 97.5 3 12.50 4.00 27.0 8 29.00 8.00 252.5 DN80 318 102 12.2 I DN200 737 203 114.5 4 12.50 4.00 26.5 10 29.00 1' 8.00 ; 265.0 DN100_ 318 102 12.0 DN250 737 203 1 120.2 6 6 3 14.00 4.50 37.0 12 29.00 8.00 295.0 DN150 x DN150 x DN80 356 114 16.8 DN300 737 203 133.8 4 14.00 4.50 36.0 14 29.00 8.00 305.0 DN100 356 114 16.3 DN350 737 203 138.3 5 14.00 4.50 44.7 182 18 6 32.00 8.50 274.0 356 114 20.3 DN450 x DN450 x DN150 813 216 124.3 8 8 4 18.00 6.00 62.0 8 32.00 8.50 275.0 DN200 x DN200 x DN100 457 152 28.1 DN200 813 216 124.7 5 18.00 6.00 75.5 12 32.00 8.50 347.0 457 152 34.2 DN300 813 216 157.4 • • 6 18.00 6.00 82.0 j 14 32.00 8.50 350.0 DN150 457 152 37.2 I DN350 813 216 158.8 10 10 4 20.50 6.50 104.8 5 20.50 6.50 99.0 32.006 6 x x DN250 DN250 DN100 521 165 1 47.5 DN400 8133 216 164.2 ' 202 20 12 35.00 9.00 415.0 521 165 _ 44.9 DN500 x DN500 x DN300 889 229 i 188.2 1 6 20.50 6.50 105.8 14 35.00 9.00 420.0 ' DN150 521 165 48.0 DN350 889 229 190.5 8 20.50 6.50 118.0 16 35.00 10.00 425.0 DN200 521 165 53.5 DN400 899 229 192.8 12 12 5 23.00 7.00 122.0 242.__. 24 16 40.00 10.00 425.0 DN300 x DN300 x 584 178 55.3 DN600 x DN600 x DN400I 1016 254 192.8 6 23.00 7.00 137.0 20 I 40.00 10.00 570.0 DN150 584 178 62.1 1 DN600 1016 254 258.6 8 23.00 7.00 147.0 For AGS fitting information, DN200 584 178 66.7 14-60 see [n 20.05 10 23.00 7.00 167.0 0N350-DN1500 AGS" • 1 o 584 ns 1 75s 1 L� J 2 For 14VDN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. • 07.01 1449 Rev AG Updated 09/2021 0 2021 Victaulic Company.All rights reserved. victaulic.com 14 �ctaulac' victaulic.com • • 4.8 DIMENSIONS 4.9 DIMENSIONS Tee Wye Adapter Nipple No. 32 No. 4012 Grv. x Thd. No. 42 Grv. x Bev. �_ IIff No. 43 Grv. x Grv. M ..111 H / r_EtoE-1 r_EtoE1 I.-EtoE--.I E, ,. 1 G 3-mm No.40 No.42 No.43 k E, • i I No.40,42,43 1 No.32 Size Adapter Nipple(s) No.32 Approx. Size Tee Wye(sw) i Actual Outside Weight Approx.: Nominal I Diameter E to E (Each) 1 • Weight inches inches inches lb '.. Nominal G H Ei E2 ,(Each) DN mm mm kg inches inches inches',,inches Inches lb '/^ 1.050 3.00 0.3 DN mm mm " mm mm kg DN20 26.9 I 76 0.1 I ._ 1.315 3.00 0.4 2 x 2 x 2 2.75 . 7.00 1 9.00 4.63 6.4 25 33.7 76 0.2 DN50 DN50 DN50 70 178 229 118 2.9 -- --- - --- 1'd 1.660 4.00 0.8 2'h x 2'h _ .. 2'h 3.00 7.75 10.50 5.75 11.5 % DN32 42.4 102 0.4 76 197 267 146 5.2 -- 11/2 1.900 4.00 0.9 3 3 3 3.25 8.50 11.50 6.50 14.3 40 48.3 102 0.4 x x DN80 DN80 DN80 83 216 292 165 6.5 • 2 2.375 4.00 1.2 3'V2 31/2 31/2 3.25 10.00 13.00 7.75 22.9 DN50 60.3 102 0.5 DN90 x DN90 x DN90 89 254 330 197 10.4 2 Y: 2.875 4.00 1.9 4 4 4 3.75 10.50 13.63 8.13 26.0 _ 73.0 102 0.9 100 x DN100 x DN100 95 267 I 346 207 11.8 3 3.500 4.00 2.5 5 x 5 x 5 4.00 12.50 16.13 10.00 48.0 DN80 88.9 102 1.1 102 318 410 254 21.8 31/2 4.000 4.00 2.1 6 6 6 4.50 14.00 18.25 11.50 60.5 DN90 _ 101.6 102 0.9 DN150 x DN150 x DN150 114 356 464 292 27.4 4 4.500 6.00 5.5 8 8 _. _. 8 6.00 18.00 23.25 15.25 127.1 DN100 _ 114.3 152 2.5 DN200 x DN200 x DN200 152 457 591 387 ' 57.7 I 5 5.563 6.00 7.4 10 10 10 6.50 20.50 27.25 18.00 190.0' 141.3 152 3.4 DN250 x DN250 x DN250 165 521 692 457 86.2 ! 6 6.625 6.00 9.5 x DN300 x 20.50 240.0 DN150 168.3 152 4.3 12 12 12 7.00 23.00 31.00 . DN300 DN300 178 584 787 1521 108.9 8 8.625 6.00 14.2 DN200 219.1 152 6.4 (s)=Carbon Steel Direct Roll Groove(OGS) 10 10.750 8.00 27.0 (sw)=Carbon Steel Segmentally Welded DN250 273.0 203 12.2 12 12.750 8.00 33.0 DN300 323.9 203 15.0 (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded NOTES • All fittings are ductile iron unless otherwise noted with an(sw)or(s). • For pump package nipples with 1 b 740mm hole cut to receive Style 923 Vic-Let or Style 924 Vic-O-Well request special No.40,42 or 43 nipples and specify No.40-H,42-H or 43-H on order.NOTE:4-127DN100- DN300 diameter-8'/200mm minimum length required. • For roll grooved systems,Victaulic offers the Advanced Groove System (AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. • Available with British Standard Pipe Threads,specify"BSP"clearly on order. • 07.01 1449 Rev AG Updated 09/2021 0 2021 Victaulic Company.All rights reserved. victaulic.com 15 �otaulricr victaulic.com • 4.10 DIMENSIONS Cap No. 60 br -t5 No.60 No.60 No.60 No.60 Size Cap Size Cap Actual Approx. ! Actual I Approx. , Outside Weight Outside I Weight Nominal 1 Diameter "T"Thickness (Each) Nominal Diameter "T"Thickness I, (Each) inches li inches inches lb inches inches inches lb DN mm mm kg DN mm mm i kg zp 1.050 0.88 0.2 6.250 1.00 6.8 DN20 26.9 22 0.1 ' 159.0 25 3.1 1 1.315 0.88 I 0.3 • 6.500 r 1.00 7.3 25 33.7 22 0.1 165.1 _ 25 3.3 - 1 1/2 1.660 0.88 0.3 6 6.625 1.00 - 6.1 DN32 42.4 22 0.1 DN150 168.3 I 25 2.8 8.625 I 1.19 13.1 l 48.3 22 0.2 219.1 30 5.9 I D 240 2.375 0.88 0.6 DN200 10 I 10.750 1.25 21.0 DNSO 60.3 22 0.3 DN250 273.0 32 9.5 21/2 2.875 0.88 1.0 12 12.750 1.25 35.6 i 73.0 22 0.5 DN300 323.9 32 16.2 3.000 0.88 1.2 142 14.000 9.50(s) + ' DN65 76.1 22 0.5 0N350 355.6 241 - -3 3.500 0.88 1.2 16° 16.000 10.00(s) + 0N80 88.9 22 0.5 DN400 406.4 254 31/2 4.000 0.88 2.5 18° 18.000 11.00(s) + DN90 101.6 22 1.1 • 0N450 457.0 279 4.250 1.00 2.3 202 20.000 12.00(s) + 108.0 25 1.0 DN500 508.0 305 4 4.500 1.00 2.5 242 24.000 13.50(s) DN100 , 114.3 25 1.1 DN600 ,_ 610.0 I 343 + 5.250 1.00 4.5 i For AGS fitting information,see publication 20.05 133.0 25 2.0 _ 14-60 5.500 1.00 4,5 DN350-DN1500 AGS- 0N125 139.7 25 2.0 --___._. Z 5 5.563 1.00 4.6 2 For 147DN350 and larger roll grooved systems,Victaulic offers the 141.3 25 2.1 Advanced Groove System(AGS).For pricing and availability of cut groove _--- fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel Direct Roll Groove(CGS) (sw)=Carbon Steel Segmentally Welded +Contact Victaulic for details. NOTES • No.60 cap is not suitable for use in vacuum service with Style 72 or 750 couplings.No.61 bull plugs should be used. • All fittings are ductile iron unless otherwise noted with an(sw)or(s). • • 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 16 �ctaulic' victaulic.com 4.11 DIMENSIONS Flanged Adapter Nipple No. 45F ANSI Class 150 Flat Face No. 45R ANSI Class 150 Raised Face No. 46F ANSI Class 300 Flat Face No. 46R ANSI Class 300 Raised Face No. 45RE PN10/PN16 Raised Face .-EtoE-y I«- EtoE-1 ,,,_EtoE-ry E Eta E�l I. .1 -I 111.11 _ _ �II I No.45F No_45RNo.46F No.46R No.45RE No.45F and No.45R No.46F and No.46R ANSI 150 ANSI 300 No.45RE • Size Flanged Adapter Nipple(s) Flanged Adapter Nipple(s) Flanged Adapter NippleI. Actual Outside Approx.Weight Approx.Weight Approx.Weight Nominal Diameter E to E (Each) E to E (Each) E to E (Each) inches inches inches lb inches lb inches lb DN mm mm kg mm kg mm kg +i 1.050 3.00 2.3 3.00 3.3 _ DN20 26.9 76 1.0 76 1.5 1 1.315 3.00 2.7 3.00 3.9 DN25 _ 33.7 76 1.2 76 1.8 !-1' 1.660 4.00 3.3 4.00 4.8 - 0N32 42.4 102 1.5 102 2.2 - - 11,2 1,900 4.00 3.9 4.00 6.9 _ _ DN40 48.3 102 1.8 102 3.1 2 2.375 4.00 6.0 4.00 8.2 2.50 5.3 DN50 60.3 102 2,7 102 3.7 64 2.4 21/2 2.875 4.00 9.9 4.00 11.9 73.0 102 4.5 102 5.4 3.000 _ _ _ - f 2.50 6.5 DN65 76.164 2.9 3 3.500 4.00 11.7 4,00 16.5 2.50 8.2 DN80 88.9 102 5.3 102 7.5 64 _ 3.7 31k 4.000 • 4.00 15.1 4.00 20.1 _ _ DN90 101.6 102 6.8 102 9.1 4 4.500 6.00 18.5 6.00 27.4 2.75 10.0 DN100 _ 114.3 152 8.4 152 12.4 70 _ ___ 45 5 5.563 6.00 21.3 6.00 35.3 141.3 152 9.7 152 16.0 - _ - -- ---- 5.500 - - _ _ 2.75 16.3 DN125 _ 139.770 7.4 6 6.625 6.00 27.5 6.00 47.5 2.75 16.3 DN150 1 168.3 152 12.5 152 21.5 70 _ 7.4 6.500 165.1 - - - - - - 8 8.625 6.00 41.3 6.00 I 70.3 • DN200 219.1 152 18.8 152 ' 31.9 - 10 10.750 8.00 59.3 8.00 100.8 DN250 273.0 203 27.1 203 45.7 - - 12 12.750 8.00 40.0 8.00 146.2 - - DN300 323.9 203 40.0 203 66.3 _ 142 14,000 8.00 8.00 DN350 355.6 203 + 203 + 162 16.000 8.00 8.00 _._._ _... _.-- DN400 406.4 203 + 203 + - - 182 18.000 -_-- 8.00 8.00 _ J DN450 457.0 _._ 203 y + 203 + 2 For 14"/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded • • • 07.01 1449 Rev AG Updated 09/2021 ©2021 Victaulic Company.All rights reserved. victaulic.com 17 �ctauliC victaulic.com 4.11 DIMENSIONS (CONTINUED) Flanged Adapter Nipple No. 45F ANSI Class 150 Flat Face No. 45R ANSI Class 150 Raised Face No. 46F ANSI Class 300 Flat Face No. 46R ANSI Class 300 Raised Face No. 45RE PN10/PN16 Raised Face r-EtoE- -EtoE-y i_,toE-y I• Et— oE-. 1.—EtoE1 _ - I 11 II It No.45F No.45R No.46F No.46R No.45RE No.45F and No.45R No.46F and No.46R ANSI 150 ANSI 300 No.45RE Size Flanged Adapter Nipple(s) Flanged Adapter Nipple(s) Flanged Adapter Nipple(s) Actual Outside 1 Approx.Weight Approx.Weight Approx.Weight Nominal i Diameter E to E (Each) E to E i (Each) E to E (Each) inches l inches '. inches ' lb inches '.. lb inches lb DN mm mm kg mm kg mm kg 202 I 20.000 l 8.00 8,00 DN500 '' 508.0 203 + 203 + 242 24.000 8.00 8.00 I DN600 610.0 203 i + 203 + 14-60 For AGS fitting information,see publication 20.05 DN350-DN1S00 AGS" E For 14/DN350 and larger roll grooved systems,Victaulic offers the Advanced Groove System(AGS)_For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded +Contact Victaulic for details NOTE • All fittings are ductile iron unless otherwise noted with an(sw)or(s). • • 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 18 jctaulrc' victaulic.com • 4.12 DIMENSIONS Swaged Nipple No. 53 Grv. x Grv. No. 54 Grv. x Thd. No. 55 Thd. x Grv. I~ EtoE1 l.-EtoE 1 1.-- EtoE 1 l.-EtoE 1 1.--EtoE EtoE-y Di 11.111 Dill Oil No.53 No.54 No. 55 No.53 No.54 No.55 No.53,54,and 55 Swaged No.53,54,and 55 Swaged Size Nipples(s) Size Nipples(s) -_-__ 1 Approx. Approx. Weight Weight Nominal E to E (Each) Nominal E to E (Each) inches inches lb inches inches lb ON mm kg DN mm kg 2 1 6.50 2.0 5 2 11.00 1 LS DN50 x DN25 165 0.9 x DNSO 279 5.2 1Y 6.50 2.0 -. 3 11.00 11.3 DN32 165 0.9 i DN80 279 5.1 11/2 6.50 2.0 l 1 4 11.00 11.5 DN40 165 0.9 DN100 279 5.2 21/2 x 1 7.00 3.0 6 1 12.00 17.0 DN25 178 1.4 DN150 x DN25 305 7.7 1 Va 7.00 3.0 1'/a 12.00 17.0 DN32 178 1.4 DN32 305 7.7 11/2 I 7.00 3.0 1' 12.00 17.2 DN40 178 1.4 DN40 305 7.8 2 7.00 3.0 2 12.00 17.4 • F- _ DN50 178 1.4 DN50 305 7.9 • ___ ---- 3 1 8.00 4.5 21/2 12.00 17.4 • DN80 x DN25 203 2.0 305 7.9 11' 11/4 8.00 4.5 3 12.00 17.4 DN32 203 2.0 DN80 305 7.9 11/2 8.00 4.5 31 12.00 17.4 DN40 _ 203 2.0 DN90 305 7.9 2 8.00 4.5 4 12.00 17.5 DN50 203 2.0 DN100 305 7.9 2 Va 8.00 _ 4.5 41/4 12.00 17.5 IL 203 2.0 305 7.9 31/4 3 8.00 6.8 5 12.00 17.5 DN90 x DN80 203 3.1 305 ' 7.9 • 4...._ 1 9.00 7.5 8 6 20.0 DN100 x DN25 229 3.4 L DN200 x DN150 + 9.1 11/4 9.00 7.5 DN32 ___ 229 g.q (s)=Carbon Steel Direct Roll Groove(OGS) •• 1'/r 9.00 • 7,5 (sw)=Carbon Steel Segmentally Welded ',, DN40 229 3.4 +Contact Victaulic for details 2 .... 9.00 7.5 NOTE • DN50 - 229 3.4 • All fittings are ductile iron unless otherwise noted with an(sw)or(s). I 2'/z 9.00 7.5 229 3.4 3 9.00 7.5 DN80 229 3.4 315 9.00 7.5 • DN90 229 3.4 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 19 �ctaulic victaulic.com 4.13 DIMENSIONS 4.14 DIMENSIONS Female Threaded Adapter Hose Nipple No. 80 No. 48 E to Eto E--.i 1�ill IIIIIIIIIQIII • No.48 No.80 1 Size No.48 Hose Nipple(s) Size No.80 Female Threaded Adapter _" "----- _ Approx. Actual Approx. Actual Outside Weight Outside Weight I I Nominal I Diameter E to E (Each) Nominal Diameter E to E (Each) inches inches inches lb inches inches inches lb DN mm mm kg DN mm mm kg 3 "__. /4 1.050 3.12 0.3 3/4 1.050 2.00 1A DN20 26.9 79 0.1 26.9 51 0.5 1 -_. 1.315 3.38 0.4 1 1.315 2.06 1.0 DN25 33.7 86 0.2 DN25 33.7 52 ! 0.5 _._... 1 Y 1.660 3.88 0.6 1 V4 1.660 2.31(sw) 1.5 DN32 42.4 98 0.3 DN32 42.4 59 0.7 1 K 1.900 3.88 0.8 11/2 1.900 2.31 (sw) 1.5 DN40 .48.3 98 0.4 DN40 48.3 59 0.7 ...... 2 � 2.375 4.50 1.1 2 2.375 2.50 1.4 DN50 i 60.3 114 0.5 DN50 60.3 64 0.6 21/2 2.875 5.38 2.0 2'/2 2.875 2.75 1.5 73.0 137 0.9 73.0 70 0.7 3 3.500 5.75 3.2 3 3.500 2.75 2.9 DN80 88.9 ' 146 1.5 DN80 1 88.9 70 1.3 4 4.500 7.00 4.9 4 4.500 3.25 4.5 DN100 114.3 178 2.2 DN100 114.3 83 2.0 5 5.563 8.75 8.0 (s)=Carbon Steel Direct Roll Groove(OGS) 141.3 222 3.6 (sw)=Carbon Steel Segmentally Welded 6 6.625 10.13 14.3 ON150 168.3 257 6.5 NOTES 8 8.625 11.88 24.7 • Available with British Standard Pipe Threads,specify"BSP"clearly on DN200 219.1 302 11.2 order. 10 10.750 12.50 40.1 • All fittings are ductile iron unless otherwise noted with an(sw)or(s). DN250 273.0 318 18.2 12 12.750 14.50 62.0 DN300 323.9 368 28.1 (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded NOTE • All fittings are ductile iron unless otherwise noted with an(sw)or(s). • 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 20 �ataulia victautic.com 4.15 DIMENSIONS Concentric/Eccentric Reducer No. 50 Concentric No. 51 Eccentric t`to El EtoE� III-EtoE1 r+EtoE�r Ito El 14-EtoE-3,1 N-EtoE-ry -EtoE� \._ Eii Fabricated Steel Fabricated Steel Fabricated Steel Fabricated Steel No. 50 No.51 No.50 No. 51 No 50 No 51 No.50 No.51 No.50 Concentric No.51 No.50 Concentric No.51 Size Reducer Eccentric Reducer Size Reducer Eccentric Reducer 1i Approx. Approx. Approx. Approx. Weight Weight Weight Weight 1 Nominal E to E (Each) I E to E (Each) Nominal E to E (Each) E to E 1 (Each) i inches inches lb inches lb inches inches lb inches lb 1 DN mm kg mm kg DN mm kg mm kg 114 3/4 1.9 - _ 1 Y4 4.6 DN32 x DN20 + 0.9 DN32 + 21 DN1 25 + 1.9 _ 1 Y 3.00(sw) 2.6 10.00(sw) 8.1 0.9 DN40 76 1.2 254 3.7 - 1'/ x 3/4 + 14 2 3.00 2.4 4.00 3.3 DN40 DN20 0.6 DN50 76 1.1 102 1.5 1 2.50 0.8 8.50(sw) 4.5 2'/2 3.00 2.7 4.00 3.4 DN25 64 0.4 216 2.0 76 1.2 102 1.5 1V4 2.50 1.0 - 3 3.00 3.2 4.00 3.5 - 0N32 64 0.5 DN80I 76 1.4 102 1.6 2 3/4 2.50 0.9 9.00(sw) 2.0 31/2 3.00 2.9 10.00(sw) 80 7 DN50 x DN20 64 _ _ 0.3 229 0.9 DN90 76 1.3 254 3.6 1 2.50 0.7 9.00(sw) 2.3 5 2 11.00(sw) 9.0 11.00(sw) 5.2 DN25 64 _ 0.3 229 1.0 x DN50 279 4.1 279 2.4 11/4 2.50 1.2 9.00(sw) 4.6 2'V2 4.00 4.3 11.00(sw) 10.8 DN32 I 64 0.5 229 I 2.1 i 102 2.0 279 4.9 ',,. 1 1/2 2.50 1.0 3.50 , 1.1 3 4.00 5.5 11.00(sw) 11.1 DN40 , 64 0.5 89 I 0.5 JI DN80 102 2.5 279 5.0 2'/2 3% 1.3 3.3 4 3.50 4.3 5.00 12.0 x DN20 + 0.6 + 1.5 1-,_... DN100 89 1.9 127 5.4 1 i 2.50 1.1 9.50 3.5 6 1 4.00 j 5.0 11.50(sw) 14.5 DN25 : 64 0.5 241 1.6 DN150 x DN25 102 '_ 2.3 292 6.6 1'4 ' 3.50 3.3 3.50 1.4 1 Y . 5.5 DN32 89 1.5 89 0.6 DN40 + 2.5 + + 1 1/2 2.50 3.6 9.50(sw) 3.7 2 4.00 6.6 11.50(sw) 14.5 DN40 64 1.6 241 1.7 ' DN50 102 3.0 292 6.6 2 2.50 3.9 3.50 4.3 1 I 2Yz 4.00 6.4 11.50(sw) 14.2 DN50 64 1.8 89 20 � 102 2.9 292 6.4 3 3/4 1.5 4.5 3 4.00 6.4 5.50 15.0 DN80 x DN20 + 0.7 + 2.0 DN80 102 2.9 140 6.8 1 2.50 1.3 9.50(sw) 4.8 4 4.00 6.5 5.50 17.0 0N25 64 0.6 241 2.2 DN100 102 2.9 140 7.7 1'74 2.50 1.4 4.8 5 4.00 6.4 5.50 17.0 DN32 64 0.6 + 2.2 102 2.9 140 7.7 I 1 Y 2.50 5.1 9.50(sw) 5.1 8 21/2 16.00 7.9 12.00(sw) 26.1 DN40 64 2.3 241 2.3 DN200 x 406 3.6 305 11.8 2 2.50 1.6 3.50 6.0 3 I 5.00 9.3 12.00(sw) 22.0 DN50 64 0.7 89 2.7 DN80 1 127 4.2 305 10.0 2 Y2 2.50 1.8 3.50 7.0 4 I 5.00 10.4 T 12.00(sw) 23.0 64 0.8 89 3.2 DN100 1 127 4.8 1 305 10.4 DN65 2.50 2.1 - - 5 5.00 11.6 112.00(sw) 23.0 '.. 64 1.0 I 127 5.2 305 10.4 • DN90 x DN80 64 0.9 241 3.2 DN1501 127 11.94 I, 152 10.0 3 Vz 3 2.50 2.0 9.50(sw) 7.0 6 ) �. i 127 5.4 I 2 0.9 4 1 3.00 3.0 13.00(sw) 6.5 DN100 x DN25 76 1.4 330 2.9 • • 07.01 1449 Rev AG Updated 09/2021 *2021 Victaulic Company.All rights reserved. victaulic.com rc 21 taulrc' victaulic.com • a 4.15 DIMENSIONS (CONTINUED) Concentric/Eccentric Reducer No. 50 Concentric No. 51 Eccentric I•to E1 EtoE-st le-.EtoE-sl I.-EtoE-ri I`to El EtoE-1 la-EtoE-ry r-EtoE-.1 Di rt- No.50 No.51 Fabricated Steel Fabricated Steel No.50 No.51 Fabricated Steel Fabricated Steel No.50 No.51 No.50 No.51 No.50 Concentric No.51 I No.50 Concentric No.51 Size Redu cer Eccentric Reducer Size Reducer Eccentric Reducer Approx. Approx. - Approx. Approx. Weight Weight Weight Weight Nominal E to E (Each) I E to E (Each) Nominal E to E (Each) E to E (Each) inches inches lb '. inches lb inches ' inches ' lb inches lb DN mm kg mm kg • DN mm kg mm kg 10 4 6.00 19.7 13.00(sw) 32.0 202 10 20.00 110.0 I 20.00 177.0 DN250 x DN100 152 8.9 330 14.5 DN500 x DN250''. 508 49.9 508 80.3 5 33.0 34.6 12 20.00 120.0 20.00 120.0 + 15.0 + 15.7 DN300 508 54.4 508 54.4 6 6.00 20.0 13.00(sw) 36.9 14 20.00 149.0 20.00 149.0 DN150 152 9.1 330 16.7 DN350_ 508 67.9 508 67.9 8 6.00 22.0 7.00 21.6 16 20.00 120.0 20.00 120.0 DN200 152 10.0 178 9.8 '.. DN400 508 54.4 508 54.4 12 4 44.0 14.00(sw) 48.0 18 20.00 136.0 20.00 136.0 DN300 x DN100 + 20.0 356 21.8 DN450 508 61.7 508 61.7 6 7.00 24.6 14.00(sw) 50.0 242 10 20.00 142.0 20.00 142.0 DN150 i 178 11.2 356 22.7 I DN600 x DN250 508 64.4 508 64.4 8 7.00 52.0 14.00(sw) 53.5 12 20.00 150.0 20.00 150.0 0N200 178 23.6 356 24.3 �; DN300I_ 508 68.0 508 68.0 10 7.00 39.0 14.00(sw) 57.0 1 14 20.00 162.0 20.00 162.0 DN250 178 17.7 356 25.9 DN350 508 73.5 508 73.5 142 6 13.00 65.0 13.00 60.0 16 20.00 162.0 20.00 162.0 DN350 x DN150 330 29.5 330 27.2 DN400 508 73.5 508 73.5 8 13.00 ' 65.0 13.00 60.0 18 20.00 162.0 20.00 162.0 DN200 330 29.5 330 27.2 DN450 508 73.5 508 73.5 10 13.00 66.0 13.00 65.0 20 20.00 151.0 '', 20.00 190.0 DN250 330 29.9 330 29.5 DN500 508 68.5 508 86.2 12 13.00 68.0 13.00 66.0 For AGS fitting information,see publication 20.05 I DN300 330 30.8 330 29.9 14-60 A�± 162 8 14.00 73.0 14.00 73.0 0N350-DN1500 AGS- DN400 x DN200 356 33.1 355 33.1 Zr 10 14.00 73.0 14.00 73.0 ` For 14700350 and larger roll grooved systems,Victaulic offers the DN250 356 33.1 355 33.1 Advanced Groove System(AGS).For pricing and availability of cut groove 12 14.00 73.0 14.00 73.0 fittings in this size,contact your nearest Victaulic sales representative. DN300 356 33.1 355 33.1 (s)=Carbon Steel Direct Roll Groove COGS) 14 14.00 73.0 14.00 73.0 (sw)=Carbon Steel Segmentally Welded DN350 356 33.1 355 33.1 +Contact Victaulic for details. 18, 10 15.00 91.0 15.00 91.0 DN450 x DN250 381 41.3 381 41.3 NOTES 12 15.00 91.0 15.00 91.0 • Available with male threaded small end No.52. DN300 381 41.3 381 41.3 • Cast fitting available for JIS size.Contact Victaulic for details. 14 15.00 91.0 15.00 91.0 • Steel eccentric reducers available through 30"/DN750,contact Victaulic DN350, 381 41.3 381 _ 41.3 for dimensions. 16 15.00 91.0 15.00 91.0 • All fittings are ductile iron unless otherwise noted with an(sw)or(s). DN400 381 41.3 381 41.3 2 For 14/DN350 and larger roll grooved systems,Victaulc offers he Advanced Groove System(AGS).For pricing and availability of cut groove fittings in this size,contact your nearest Victaulic sales representative. I • 07.01 1449 Rev AG Updated 09/2021 ©2021 Victaulic Company.All rights reserved. victaulic.com 22 jetaulra' victaulic.com 4.16 DIMENSIONS Small Threaded Reducer No. 52 No. 52F E E E E t t~to Eel Ito El t+[o E+l III Bill III El No.52 No 52F No.52 No 52F No. 52F Concentric tNo.52F Concentric No.52 Reducer with BSPT No.52 Reducer with BSPT 1 Size Small Threader Reducer Female Threaded End Size Small Threader Reducer Female Threaded End Approx. Approx. , Approx. Approx. 1 i Weight ' Weight ' Weight Weight Nominal E to E (Each) E to E (Each) Nominal E to E (Each) E to E (Each) inches inches lb 1 inches inches lb DN mm kg mm ' kg DN mm kg mm kg 1 Y 1 2.50 0.8 _ - 4 1 3.00 2.3 I - - DN40 x DN25 64 0.4 DN100 x DN25 76 1.0 1N 2.50 1 0.9 1'h_.. 3.00 -.... 2.7 DN32 64 0.4 - - DN40 76 1.2 - - 2 /4 2.50 0.9 2 3.00 2.6 - x 364 0.4 - - DN50 12 ' - - DN50 DN20,, 76 . a._ _ - 1 2.50 0.7 _ _ 21/2 i 3.00 2.6 DN25 64 0.3 76 1.2 - - 1'74 2.50 1.2 _ _ 3 3.00 2.5 - _ DN32 64 0.5 DN80 76 1.1 - 1'k 2.50 1.0 - - 108.0mm x 42.4mm 76 1.3 76 1.3 DN40 64 0.5 21/2 1 2.50 1.1 x DN25 64 0.5 - - 48.3mm 76 1.3 76 1.4 1'/. 2.50(sw) 1.2 - - 60mm - - I 76 1.4 DN32 64 0.5 11/2 2.50(sw) 1.3 DN40 64 0.6 - - 114.3mm x 42.4mm 76 1.3 76 1.3 2 2.50 1.4 - 48.3mm 76 1.3 76 1.3 DN50 64 _ 0.6 DN65 x DN40 64 0.8 64 0.8 60mm 76 1.3 76 1.4 2 - 5 4 - - DN50 - 64 0.9 x DN100 + 5 4.2.5 3,4 3 x DN20 +(sw) 0.7 1'S DN80 - - 133.0mm x 60mm - - 114 2.2 li 1 2.50 1.3 0.6 DN25 64 0. - - :139.0mm x 60mm - - 114 2.3 11/4 2.50 1.5 - - 6 1 - 4.00 5.5 - - DN32 64 0.7 DN150 x DN25 102 2.5 - 1Vz 2.50(sw) 1.5 , _ _ 2 4.00 5.7 - _ DN401 64 0.7 DNSO 102 2.6 I 2 2.50 1.5 _ _ 251 4.00 5.8 _ f DN50 64 0.7 102 2.6 2'/2 2.50 2.4 3 4.00 5.8 64 1.1 li DN80 102 2.6 - 88.9mm x 42.4mm 64 0.9 64 0.8 DN100 +(sw) 29 48.3mm 64 0.9 64 0.9 5 +(sw) 2.0 - 60mm - - 64 0.9 159.0mm x 42.4mm 114 2.2 144 2.5 (s)=Carbon Steel Direct Roll Groove(OGS) 48.3mm 114 2.2 114 2.5 (sw)=Carbon Steel Segmentally Welded -- --- -- ------' +Contact Victaulic for details. 60mm - 114 2.6 • 07.01 1449 Rev AG Updated 09/2021 ©2021 Victaulic Company.All rights reserved. victaulic.com 23 'ctauhcr victaulic.com 4.16 DIMENSIONS (CONTINUED) Small Threaded Reducer No. 52 No. 52F E E IIrI �� No.52 No 52F No.52 No.52F Concentric Small Threader Reducer with BSPT Size Reducer Female Threaded End Approx. Approx. Weight Weight Nominal E to E (Each) E to E (Each) inches inches lb DN mm kg mm kg 165.1mm x 42.4mm 102mm 2.4 102 2.9 48.3mm 102mm 2.6 102 3.0 60mm — — 102 3.0 8 2 16.00 1.5 DN200 x DN50 406 0.7 2�h I 16.00 1.7 406 0.8 (s)=Carbon Steel Direct Roll Groove(OGS) (sw)=Carbon Steel Segmentally Welded NOTES • Available with British Standard Pipe Threads,specify"BSP"clearly on order. • All fittings are ductile iron unless otherwise noted with an(sw)or(s). • • 07.01 1449 Rev AG Updated 09/2021 132021 Victaulic Company.All rights reserved. victaulic.com 24 �ctsiulio' victaulic.com • • 5.0 PERFORMANCE Flow Data (Frictional Resistance) The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 221/°elbow is approximately one-half the resistance of a 45°elbow. Values of mid-sizes can be interpolated. Size Dimensions T 90°Elbows 45°Elbows Tees Actual ( No. 100 No. 110 Outside No. 10 1 D Long No. 11 i 1 r D Long Nominal Diameter Std.Radius Radius Std.Radius ! Radius Branch Run inches inches feet feet feet feet feetI. feet DN mm meters meters meters meters meters meters 1 1.315 1.7 _ 0.8 _ 4.2 1.7 ON25 33.7 0.5 0.2 _ 1_ 1.3 0.5 2 2.375 3.5 2.5 1.8 1.1 8.5 3.5 DN50 ' 60.3 1.1 0.8 0.5 0.3 2.6 1.1 3.000 4.3 _ 2.1 _ 10.8 - 4.3 DN65 76.1 1.3 0.7 3.3 1.3 I 3 3.500 5.0 3.8 2.6 1.6 13.0 5.0 DN80 88.9 1.5 1.2 _ 0.8 0.5 _._... 4.0 1.5 I 4.250 6.4 3.2 _ 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 5.0 3.4 j 2.1 li 16.0 6.8 DN100 114.3 2.1 1.5 1.0 0.6 4.9 2.1 5.250 8.1 _ 4.1 20.0 8.1 133.0 _ 2.5 1.2 - 6.2 2.5 _ -_...5.500 8.5..._. ..-_- ,, 4.2 21.0 8.5 ON125 139.7 2.6 I 1.3 6.4 2.6 5 5.563 8.5 4.2 21.0 8.5 - 141.3 2.6 [ 1.3 6.4 2.6 6.250 9.4 - 4.9 _ 25.0 9.6 159.0 2.9 1.5 7.6 2.9 6.500 9.6 - 5.0 _ 25.0 10.0 165.1 2.9 _ I _ 1.5 7.6 3.0 6 ' 6.625 10.0 7.5 5.0 3.0 25.0 10.0 DN150 168.3 3.0 2.3 1.5 0.9 7.6 3.0 8 8.625 13.0 ' 9.8 6.5 4.0 33.0 13.0 DN200 219.1 4.0 3.0 2.0 1.2 10.1 4.0 10 10.750 17.0 12.0 8.3 5.0 41.0 17.0 DN250 273.0 5.2 3.7 2.5 1.5 12.5 5.2 12 12.750 20.0 14.5 10.0 6.0 50.0 20.0 DN300 323.9 6.1 4.4 3.0 1.8 15.2 6.1 14 14.000 24.54 15.8 18.54 11.0 70.0 23.0 !' DN350 355.6 7.5 4.8 5.6 3.4 21.3 7.0 16 16.000 28.04 I 18.0 21.04 13.0 80.0 27.0 DN400 406.4 1 8.5 5.5 6.4 4.0 24.4 8.2 1 18 18.000 -- 31.04 20.0 23.54 14.0 90.0 30.0 DN450 457.0 - 9.5 6.1 7.2 4.3 27.4 9.1 I. 20 20.000 I 34.04 22.5 25.54 16.0 100.0 33.0 DN800 1__... 508.0 j 10.4 6.9 7.8 4.9 _ 30.5 10.1 24 i 24.000 42.04 27.0 29.54 19.0 120.0 40.0 0 i_.. 610.0 12.8 8.2 9.0 5.8 36.6 12.2 N600 AGS fittings available up to 60'7DN1500.Contact Victaulic for details. AGS" 4 Fitting flow data for 14-247DN350-DN600 size No.10 and No.11 Elbows is based on fittings for Style 07 and 77 couplings.For flow data on AGS fittings(No. W10 and No.W11 Elbows),refer to publication 20.05. • , 07.01 1449 Rev AG Updated 09/2021 0 2021 Viclaulic Company.All rights reserved. victaulic.com 25 'ctaulic' victaulic.com • • • • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in POF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patentor other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement ofany patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design er utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. • • 07.01 1449 Rev AG Updated 09/2021 ®2021 Victaulic Company.All rights reserved. victaulic.com 26 jotaulia ''i' 1 - ,•,....ftigiroli 4 1 .. ' I 1 , A I •--1**\ 1Thip--7--- , • .1. ' 2 t x ' IMI 1• . t: , . 1 t.i'") , I L •.';', , e il ' I1' cc '' • • .44 '# i . V) . f i ICC 0 • 11111 .. - ,I, a 1.•11 a • 4 4 4• ' • Z MOM —.... • ICC , CI= s • 1 °:7' ie l' . '°. • '' ••• S •• . -----•44-e-rest*""°: 10,.."...iimarro ?T , , -7111114,,:i. ,,, , „ ..74eNiff'ffir' litt.ut*.w.,••• : ...': ;V,, g ., .; IIM ' "4 4.4•4 4 i.........i........400 ""d16011.0. ". 1 -.-,...._ „ • i 4d = , . w It CI 4 , 6 . )1 0 ml u..E. , , . ,,.. • ,.. ) . .1/4\ , , I 1 I \., I, :. ,,, . ,, • • 1 1 i :.- I, , I' ,.., .• ,,,,, 4 i . 1 11111111111111116.- I i \ t . We invented the concept of flexible fire protectionT'" 4 The FlexHeae i-avatnacge FLEXHEAD® QUALITY FLEXHEAD® FEATURES • Best corrosion resistance • Is seismically qualified for use, 71_- , Made from 1000/o 304 stainless steel eliminating the need for an oversized • Excellent friction loss values ring around the sprinkler head in One-inch true-bore ID reducing the seismic areas need to upsize mains and branch lines, • Has the same product design that is 1 :: 1 Y4" available dual listed by both UL and FM '.F a £ • Pressure surge protection • Can be produced domestically to n -, ,,�; Fully braided connection improves pressure meet all your project requirements ,,w-, �, capability and prevents hose damage • Has serial identification with complete t� • Highest maximum working pressure audit tracking of finished goods Rated upto 300 psig • Has a comprehensive limited warranty 4 . t�,: , • No o-rings or gaskets backed by an A++ insurance company Welded connections reduce potential leak • Offers a variety of flexible fire sprinkler points at the inlet and outlet fitting connections, suspended ceilings, gypsum • Tightest thread tolerances board ceilings, institutional applications, Outlet fitting threads are machined from cleanroom and duct applications solid bar stock reducing potential leaks • Offers 1.25" FlexHead® hose for superior at the sprinkler head fit-up friction loss numbers • Extra stability Bracket has a full 6-inch base to stabilize the sprinkler head during installation, pressurization or activation .0; ' 7:-..% 1",,..-, It'' , mu , k tic ~ , . Ax k TABLE OF CONTENTS Introduction 2 Table of Contents 3 Installation Instructions 4 - 7 NFPA 13 Code Language and Seismic Qualification 8 - 9 Friction Loss Data and Specifications 10 - 11 Suspended Ceiling Detail 12 Hose Specification Sheet 13 Bracket Specification Sheet 14 FlexHead`" Commercial Products 15 FlexHead" Sprinkler Hose Fittings 16 Warranty 17 Whether your application is commercial, industrial, clean room, or institutional, FlexHead" flexible sprinkler systems can save you time and money by offering reliable, highly efficient, seismically qualified, and environmentally responsible products. U.S.and international patents pending:#6,123,154,#6,1 19,784,#6,752,218,#7,032,680,#6,488,097. The FlexHead name and logo are trademarks of FlexHead Industries,Inc. FGG/BM/CZ"System Compatible indicates that this product has been tested,and is monitored on an ongoing basis,to assure its chemical compatibility with FlowGuard Gold",BlazeMaster"and Corzan"'pipe and fittings.FGG/BM/CZ'",FlowGuard Gold', BlazeMaster',and Corzan'are licensed trademarks of The Lubrizol Corporation USGBC and LEED are registered trademarks of the U.S.Green Building Council.The FlexHead"Commercial Products have been tested and evaluated by Spears"'for acceptable use with FlameGuard CPVC Fire Sprinkler products. FiExHEAu 800.829.6975 NDUS TRIES"L� sL�alkore ' We invented the concept of flexible fire protection' iipi iil ►` fil Rio 11 1 Rt o 1 1 i y 1+'' 1' 111Iz'1_11 II. � _�� Installation of FlexHeacr Commercial Ceiling Flexible Sprinkler Drop System For use with FlexHead®hoses; 2024T, 2036T, 2048T, 2060T, 2072T 2024ET, 2036ET, 2048ET, 2060ET, 2072ET —00 4 T Bar Ceiling Grid Installation FlexHead® Flexible Hose Installation The bracket is designed for use on ceiling grids conforming 1.Apply Teflon®tape and pipe sealant to the 1"NPT to ASTM C635. thread. Install into branch outlet. Any direction is 1) Locate the center of the ceiling tile marking, then align acceptable, ensure the hose is allowed at least one the screw hole for true center of tile installation. bend per installation to allow for seismic movement. 2)Clip the bracket on the T-Bar Ceiling Grid. 2. Tighten hose using the pipe drop section, never apply 3)Center of the leg section must be on the outside of a wrench to the braided hose for installation. the T-Bar(Figure 1). 4)Secure each bracket leg to the T-Bar with#2 Head self Fig.2 " tapping screw. " rt (Fig.1 - MD • 1 MPO Bracket Shown t 1i L k ` , 4, -r M - t a.. a. L Do not wrench on braided hose 4 F EXHEAD' INDUSTRIES-7- www.flexhead.com Secure the FlexHead®Sprinkler Drop to Bracket Adjustment for Multiple Positions the Bracket 1. MPO Hub Adjustment-Remove the nut and screw 1. Maneuver the flexible sprinkler drop from the branch on the hub assembly. Slide out the tab and move to to the bracket. Review that the hose length, number desired position. Insert tab into square opening at of bends, and bend radius are applicable for the desired position and install screw from below. Install installation per NFPA guidelines. (See corresponding nut and tighten to hand tight plus one turn. hose technical data sheet for installation information on pages 10-11.) 2. The bracket has an open hub for ease of installation. Open the hinge apparatus by turning the locking shaft 1/4 turn. Slide the flexible hose into the hub. Ensure the - • drop is vertical and the SS Flexible® hose is not applying I E a substantial moment on the bracket, causing sprinkler misalignment. Latch the hinge door close and adjust the sprinkler drop for desired ceiling height. Tightening the set screw till hand tight plus 1 full revolution, (100 in-Ibs). 3. Install desired sprinkler head per the manufacturer's installation instructions. ``} 2. ADO Hub Adjustment- Loosen screw and nut on each side of the hub, do not remove. Slide the hub to the desired position and tighten screw on each side. Tighten the nut to hand tight plus one turn. m � 1 -40 • Fig.3 MPO Bracket Shown J 1111 U.S. and International Patent Pending: #6,123,154, #6,119,784, #6,752,218, #7,032,680, #6,488,097 � J EXHEACi 800.829.6975 �U S T R 5 vL\�atlmre We invented the concept of flexible fire protection' INSTALLATION INS, 4,9 UCTIONS — ADJT-24-BKT1 Installation of FlexHead® Commercial Ceiling FlexHead® Flexible Hose Installation Flexible Sprinkler Drop System A.Apply Teflon®tape and pipe sealant to the 1" NPT thread. Install into branch outlet.Any direction is Multi Position Tall Bracket(MPT) TO Red Bar acceptable, ensure the hose is allowed at least one ADJT-24-BKT is approved for use with the standard bend per installation to allow for seismic movement. FlexHead®Flexible Sprinkler hose. See corresponding B.Tighten hose using the pipe drop section, never apply technical data sheet for installation information. a wrench to the braided hose for installation. (Fig. 2) Fig.2 >`„' , , - 1 a FlexHead®Standard Tall *; 2024T, 2036T, 2048T, 2060T, 2072T '\ t� Secure the FlexHead® Sprinkler Drop to, •�� r MPT Bracket s'te FlexHead®Standard Tall Elbow A. Maneuver the flexible sprinkler drop from the branch to 2024ET, 2036ET, 2048ET, 2060ET, 2072ET the MPT bracket. Review that the hose length, number The MPT bracket is set for 24"center of tile installation. of bends, and bend radius are applicable for the installation per NFPA guidelines. (See Corresponding (See next page for additional installation configurations) hose technical data sheet for installation information on T Bar Ceiling Grid Installation pages 10-11.) The MPT bracket is designed for use on ceiling grids B. The MPT bracket has an open hub for ease of conforming to ASTM C 635. installation. Open the hinge apparatus by turning the A. Locate the center of the ceiling tile marking, align the locking shaft '''A turn. Slide the flexible hose drop into offset screw with that marking for true center of the hub. Ensure the drop is vertical, and the SS Flexible tile installation. hose is not applying a substantial moment on the Insert one bracket leg at a time, applying a downward bracket causing sprinkler misalignment. Latch the pressure on the bracket leg and T-Bar, screw the hinge door close and adjust the sprinkler drop for self-tapping screw using a#2 square head driver. Place desired ceiling height.Tightening the set screw till hand the second leg on the T-Bar and repeat process. tight plus 2 full revolutions, (130 in Ibs). (Fig. 3a (Fig. 1) and 3b) C. Install desire sprinkler head, per the manufactures • . �•1 installation instructions. '". . Fig.3a sue• U 'XiiEA3 r1 rt :99 ' -e fir_ 4. i .• 4 'SO ii/ ini1111,- FLOCHEALf Do not wrench on braided hose 6 INDUSTRIES www.flexhead.com _Las Ceiling Tile Installation Installation Configuration A. The flexible sprinkler drop system with MPT Bracket is able to be installed prior to the ceiling tile installation, preventing the need for sprinkler contractor tile adjustment. 24"Tile—24/4 P Quarter Mark B. For ease of tile installation, cut the largest sprinkler hole Position recommended by the manufacture. The largest hole that is still covered by the sprinkler escutcheon allows for an easier install. C.Angle the tile at 45 degree and push the tile through the ,.. — ii°700. . hole and up above the ceiling T-bar, maneuver the tile and allow it to drop in the proper location. (Fig.4) 16"Tile- 16/2 Center Position iW 16"Metal Stud ` (Web Size>5") ---� Center Position \ lik. ' -ler} CO 0 %kik, 14-1/2"Wood Stud " • IA!! Center Position U.S and International Patent Pending: #6,123,154,#6,119,784, #6,752,218,#7,032,680,#6,488,097 FLEXHEACi 800.829.6975 rn u s r e 7 We invented the concept of flexible fire protection' NFPA 13 CODE LANGUAGE & SEISMIC QUALIFICATION NFPA 13 STANDARD FOR INSTALLATION OF SPRINKLER SYSTEMS 2016 EDITION 9.2.1.3.3 Flexible®Sprinkler Hose Fittings. 9.2.1.3.3.1 Listed flexible sprinkler hose fittings and their anchoring components intended for use in installations connecting the sprinkler system piping to sprinklers shall be installed in accordance with the requirements of the listing, including any installation instructions. 9.2.1.3.3.2 When installed and supported by suspended ceilings,the ceiling shall meet ASTM C 635, Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-In Panel Ceilings, and shall be installed in accordance with ASTM C 636, Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-ln Panels. 9.2.1.3.3.3 When flexible sprinkler hose fittings exceed 6 ft(1.83 m) in length and are supported by a suspended ceiling in accordance with 9.2.1.3.3.2, a hanger(s)attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft. (1.83 m). 9.2.1.3.3.4 Where flexible sprinkler hose fittings are used to connect sprinklers to branch lines in suspended ceilings, a label limiting relocation of the sprinkler shall be provided on the anchoring component. A. 9.2.1.3.3.3 The committee evaluation of flexible sprinkler hose fittings supported by suspended ceilings was based on a comparison of the weight of a 6 ft, 1 in (1.8 m) diameter Schedule 40 water-filled unsupported armover weighing approximately 13 lb(5.9 kg)to the weight of a 6 ft, 1 in. (1.8 m)diameter water-filled flexible hose fitting weighing approximately 9 lb(4.1 kg). The information provided to the committee showed that the maximum load shed to the suspended ceiling by the flexible hose fitting was approximately 6 lb(2.7 kg)and that a suspended ceiling meeting ASTM C 635, Standard Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems of Acoustical Tile and Lay-1n Panel Ceilings, and installed in accordance with ASTM C 636, Standard Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-In Panels, can substantially support that load. In addition,the supporting material showed that the flexible hose connection can be attached to the suspended ceilings because it allow the necessary deflections under seismic conditions. A.9.2.1.3.3.4 An example of language for the label is as follows: CAUTION: DO NOT REMOVE THIS LABEL. Relocation of this device should only be performed by qualified and/or licensed individuals that are aware of the original system design criteria, hydraulic criteria, sprinkler head listing parameters, and knowledge of the state and local codes including NFPA 13 installation standards. Relocation of the device without this knowledge could adversely affect the performance of this fire protection and life safety system. Reproduced with permission from NFPA 13-2016, Standard for the Installation of Sprinkler Systems, Copyright© 2015, National Fire Protection Association. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. 8 FL EAID INbUStRIES'L4 www.flexhead.com FLEXHEAD° SATISFIES SEISMIC CODE REQUIREMENTS The FlexHead®hose allows the head to move Typically, each unit consists of a threaded pipe in any direction during a seismic event without nipple for connecting to the main or branch causing damage to the sprinkler system. feeder line, a flexible hose in standard lengths, �+ �/ I1!!!!!! •!!!+!!1!!!!!!!!!!�!!!!!!!!!!!a reducing fitting that the sprinkler head attaches loffi;.»«:4 4 a+ .+s 411I14 494 4t� tit to, and a mounting bracket. Vfoi" Mounting Bracket I 'Ceiling Tle FlexHead®Industries recently satisfactorily completed full-scale seismic qualification testing at the Structural Engineering Earthquake Simulation Laboratory located at the State University of New York at Buffalo. Tests were conducted using the International Code Council(ICC)acceptance criteria"ICC-ES AC-156 Seismic Qualification Testing of Nonstructural Components". • More than 90% of the states in the U.S. are adopting the • In Seismic Design Categories D, E&F, suspended International Building Code(IBC)that address, among ceilings are to be designed and installed in accordance other things,the installation of fire sprinkler systems in with CISCA recommendations for seismic Zones 3 and 4 seismic zones. with some additional requirements. Except where rigid •The latest version of the IBC defers to ASCE 7 for the braces are used to limit lateral deflections, sprinkler heads and other penetrations shall have a 2-inch oversized ring, sprinkler/ceiling design in Seismic Design Categories 9SDC)C and D, E&F. sleeve,or adapter through the ceiling to allow for free movement of at least 1 inch of ceiling movement in all • In Seismic Design Category C, suspended ceilings are to horizontal directions. be designed and installed in accordance with Ceilings& Interior Systems Construction Association (CISCA) • Flexible sprinkler connection provide characteristics that exceed the most stringent seismic code requirements. recommendations for Zones 0-2; and sprinkler heads and other penetrations shall have a minimum of 1/4-inch The flexibility of the hose allows the head to move with clearance on all sides. the ceiling in any direction during a seismic event without causing damage to the sprinkler system. FLExHmo 800.829.6975 INDUSTRIES-L.4 9 _�aakon We invented the concept of flexible fire protectionTM FRICTION LOSS DATA & SPECIFICATIONS Minimum Bend Maximum 1 Max Rated Outlet Hose Radius Number of Equivalent Length of tin.Diameter Schedule 40 Pipe(Ft) Pressure Model Orifice Assembly 90*Bends PSI(Kpa) Number Si Length UL FM 5.6k-factor 8.0k-factor 11.2(FM) (FM) 1k-factor 14.0k-factor 168k-factor IFfa UL FM in(cm) in(mm) FM UL IULI 22.4k-factor PSI PSI in(mm) in Om) Ft(m) Ft(m) Ft(m) Ft ON Ft(m) Ft(m) Ft(m) (Kpa) (Kpa) 1"INTERNAL DIAMETER(1.0.)HOSE SERIES 2024T-50 ', 2416101 3 1 11 18.4(5.6) 1 7.712.3) --- 7.512.31 - - - 20361-50 361914) 3 2 16 26.6(8.1) 11.513.51 11.513.51 - - - 20487-50 h 4811219) 8 3 4 3 24 30.3(9.2) 15.3(4.61 15.414.71 - 175 ! 175 11.27) 1200) 176.2) - (12051 (12051 2060T-50 60115241 ",. 4 4 29 35.8110.9) 19.1(5.8) 19.315.81 - - - 2072T-50 72(18281 4 4 35 45.6(13.91 23.0171 23.2(7) - - - 2024T-75 241610) '. 3 1 12 I - - - 14.714.5) 7.112.11 - 2036T-75 3619141 3 2 18 - 21.5(6.5) 21.6(6.61 21.8(6.61 10.913.31 - 8 3 175 175 20481-75 11/90) . 4811219) (200) (76.2) 4 3 23 - 30.519.31 30.6(9.3) 2918.8) 14.801.5) - 112051 (1205) 2060T-75 60(1524) 4 4 29 - 39.5(121 39.6(121 36.1(11) 18.715.6) - 2072T-75 72(1828) 4 4 1 32 - 48.5(14.71 48.8(14.91 43.2(13.1) 22.6(6.8) - 2024E7-50 24(610) 3 1 19 26.4(8.0) 6.812) i 7.412.2) • - - 2036E7--50 36(914) 3 2 23 30.1(9.1) 11.8(3.6) 12.5(3.8) - - - 2048ET-50 (127) 48(12191 81200) 3 4 I 3 27 33.8(10.3) 16.915.1) 17.615.31 - .,. - 175 175 17611 (12051 (12051 2060ET-50 60115241 4 I 4 32 37.5111.41 21.9(6.6) 22.7(6.91 - - • - 2072E1-50 li 72118281 4 4 35 41.2(12.5) j 21.0(6.2) 27.818.4) - . _ 2024ET-75 241610) 3 1 I 18 j - - - 14.714.5) 8.2(2.5) - '..• 2036E11-75 3619141 3 2 23 - 25.2(7.7) 2617.9) 21.8(6.6) 13(3.91 • - 75 2048E0-75 ' �� 4811219) 8 3 4 3 23 - 32.91101 '.. 33110) 29(8.8) 17.815.41 �', - 175 ' 11.901 12001 176.21 112051 11205) 2080ET-75 60(1524) 4 4 29 - 40.6(12.3) ; 40112.11 36.1111.01 22.616.81 - r 2072ET-75 72)18281 4 4 32 - 48.5(14.71 47114.3) 432(13.1) 27.5(8.3) - 2024E-50 24(610) " 3 1 19 26.4(8.0) I - ' - - - - 2036E-50 36(914) ', 3 2 23 30.1(9.2) I - - - - - 2048E-50 �� 48(1219) 8 3 4 3 27 33.8)10.3) - • - 175 175 (1.27) 12001 (76 2) t (1205) -112051 2060E-50 60(1524) 4 4 32 37.5111.4) 1 - - - 2072E-50 72)1828) 4 4 35 41.2112.6) - - 2024E-75 I 24(6101 3 1 18 '', - ' 14.714.5) ) - - - - 2036E-15 36)914) 3 2 ii, 23 - 121.816.6) I - - - - 2048E-75 3� 48(1219) 8 3 4 3 '.1 23 - 29.018.81 - 175 175 (1.901 1200) (76.21 (1205) 11205) 2060E-75 60115241 4 4 29 - ' 36.1(11.0) - - - - 2072E-75 1 72(18281 4 1 4 j 32 - j 43.2(13.2) - ( - ' - I - I Notes: Chart continued on the next page •Model Numbers:The"T'designates tall drops length hose series.The"ET"designates tall elbow drop hose series.THE°E"designates elbow drop hose series.The"H"designates high pressure 300PSI working pressure hose series.The"HE°designates high pressure 300PSI elbow hose series.The°F" designates high flow rate using 1-14 I.D.hose series.The"DPS"designates dry pendent system hose series. • Max ambient temperature rating on all model numbers are 300 F(148 C). •Equivalent lengths are shown with maximum number of 90 degree bends at the minimum bend-radius per agency.Different values were obtained by FM and UL due to the difference in minimum bend radius,testing protocol and calculation methods.Please see individual standards for more information relative to friction loss(equivalent length of pipe). •FM equivalent length calculation includes sprinkler head friction loss. •See listing(s)approval agency for the latest approval details. •FlexHead products are intended for use in hydraulically designed wet,pre-action,deluge or dry pipe sprinkler connections per NFPA 13, 13R and 13D guidelines. 1 o IUSTR www.flexhead.com .A ': FRICTION LOSS DATA & SPECIFICATIONS (cont'd) Minimum Bend Maximum ', l Max Rated Pressure Outlet Hose Radius Number of Equivalent Length of lin.Diameter Schedule 40 Pipe(Ft) PSI/Kpal Model Orifice Assembly 901 Bends Number Size Length FM UL (FM) (FM) (FM) IFM) (FM) (FM) in(cm) in km) in in UL FM (UL) 5.6k-factor 8.0k-factor 11.2k-factor 14.0k-factor 16.8k-factor 22.4k-factor UL PS! FM PSI (mm) ! OW I Ft On) Ft FIlml klml Ftlm) Ft(m) F lm) KpaJ (Kpa) 1"INTERNAL DIAMETER(ID.)HOSE SERIES • 2024H50 ',. 24(6101 3 2 11 18z-(5.61 7.7(2.31 7.6(2.3) 2036H-50 36(914) 3 3 16 26.6(8.1) 11.5(3.5) 11.5(3.5) - - - 2048H-50 A4811219) 8 3 l 4 4 24 30.3(9.2) 15.3(4.61 15.4(4.7) - - - 300 PSI 300 PSI (127) 1200) (7621 (2068Kpa) (2068Kpal 2060H-50 60(1524) 4 4 29 35.8(10.91 19.115.81 19.3(5.8) - - - 2072H-50 7211828) •',. 4 4 35 45.6(13.91 1 23)7) 23.217) - - - 2024H-75 241610) 3 2 12 - 14.7(4.5) 14.7(4.5) 14.714.51 7.1 12.11 - '.. 2036H-75 36(914) 3 3 18 - 21.8(6.6) 21.6(6.5) 21.816.6) 10.9(3.3) - 2048H-75 ��` 4811219) 8 3 4 4 23 - 29(8.8) 30.619.3) 29(8.81 14.814.5) - 300 PSI 300 PSI (1.90) 12001 176.21 12068Kpel (2068Kpa) 2060H-75 60(1524) 4 4 29 - 36.1(11.0) 39.6(12) 36.1(11.01 18.7(5.71 - 2072H-75 72(1828) 4 4 !. 32 I - 43.2(13.1) 48.8(14.8) 43.2(13.1) 22.6168) - • 2024HE-50 241610) 3 2 19 14.7(4.5) 6.8(2) 7.4(22) - - - 2036HE-50 36(9141 3 3 23 21.8(6.61 11.8(3.6) 12.513.8) - - - 2048HE-50 48(1219) 8 3 4 4 27 29.0(8.8) 16.9(5.11 17.6(5.3) - - 300 PSI 300 PSI 11.27) (2001 (76.2) (2068Kpa) (2068Kpa) 2060HE-50 6011524) 4 i 4 32 36.1(11) 21.9(6.6) 22.8(6.9) - - 2072HE-50 7211828) 4 1 4 35 43.2(13.1 2718 2) 27.8(8.4) - - - 2024HE-75 I 24(610) 3 2 I 18 - 14.7(4.5) - 14.714.5) 8.212.5) - _ 2036HE-75 36(914) 3 3 23 - 21.8(6.6) 26(7.9) 21.816.6) 1313.91 - • • 300 PSI 300 PSI 2048HE-75 (1.90) 48112191 (200) 17611 4 4 23 - 29(8.8) 33(101 29180 17.8(5.4) - (2068Kpa) (2068Kpal 2060HE-75 '.. 60115241 Ali 4 4 29 - 36.1111.0) 40112.2) 36.1(11.0) 22.6(6.8) - 2072HE-75 ', 72(18281 j 4 4 32 - 43.2(13.11 471143) 43.2113.1) li 27.5(8.3)• - 2024DPS 24(610) i - 1 - 18.4(5.6) 7.7(2.3) 7.6(2.3) ' 7.1 12.1) 10.7(3.3) 2036-DPS 36(9141 - 2 - 26.6(8.1) 11.5(231 - 11.513.5) I - 10.9(3.3) 15.1(4.8) 2048-DPS (2 541• 4811219) (180) - 3 - 30.3(9.2) I 15.313.51 15.4(4.7) - 14.8(4.5) 215(6.5) - 175 1205) 2060-DPS 6011524) -- 4 - 35.8(10.9) ( 19.1 15.8) 19.3(5.9) - 18.715.71 25317.7) 2072-DPS 72118281 - 4 - 45.6(13.9) 23(7) 23.2(71 - j 22.616.9) F 26.918.11 1"INTERNAL DIAMETER(I.D.)HOSE SERIES 2036F-50 36(914) - 1 - 4.1)1.2) 4.1(1.2) 4.1(1.2) - - 1 - 2048F-50 (127) 48)1219) (180) - 2 5.411.6) 5.6(1.71 5.7(1.71 - - - - 175 1205) 2072F-50 7211828) - 4 - 8.0(2.4) 8.612.6) 9.1(2.7) - 1 - - 2036E-75 36)914) ', - 1 - - - - 3.4(1.0) 3.4)1.0) - '.. 75 2048E-75 (1.9D)• 48(12191 (1801 F - - 2 I - - - - 4.8(1.51 4.811.4) - - (112 5) 2072E-75 7211828) F - 4 - - - - 7.6(2.3) 7.612.3) - 2036F-100 36(9141 I I i - 2 - i - - - I - 'I - 3.411.01 75 2048F-100 (2.54) 48(1219) (160) ',, - 3 - - - II - - 4.811.41 L (112 5) 2072F-100 [ I 72116281 4 ,: - , - - - - I 7.6)2.3) Notes: •Model Numbers:The"T"designates tall drops length hose series.The"ET"designates tall elbow drop hose series.THE"E"designates elbow drop hose series.The"H°designates high pressure 300PSI working pressure hose series.The"HE°designates high pressure 300PSI elbow hose series.The°F" designates high flow rate using 1-1/4 I.D.hose series.The"DPS"designates dry pendent system hose series. •Max ambient temperature rating on all model numbers are 300 F(148 C). • •Equivalent lengths are shown with maximum number of 90 degree bends at the minimum bend-radius per agency.Different values were obtained by FM and UL due to the difference in minimum bend radius,testing protocol and calculation methods. Please see individual standards for more information relative to friction loss(equivalent length of pipe). •FM equivalent length calculation includes sprinkler head friction loss. •See listing(s)approval agency for the latest approval details. •FlexHead products are intended for use in hydraulically designed wet,pre-action,deluge or dry pipe sprinkler connections per ���/,,/��� NFPA 13, 13R and 13D guidelines FLOC HEMS 800.829.6975 INDUSTRIES'L4 11 We invented the concept of flexible fire protectionTM' FLEXHEAD° CEILING DETAIL .. FlexHeadr Suspended Ceiling Detail FlexHead°MPO24BKT2 FlexHead®ADJT24BKT1 Bracket Bracket :i :;! it 1" ". 1i i1 "Allows for bracket installation without pre-installing the ceiling tile FlexHead Sheetrock Ceiling Detail FlexHead®MP024BKT2 FlexHead®ADJT24BKT1 _ Bracket t:-:+yw}�:: __ } i i Bracket : if - 1 --. L 1 Each FM approved and UL listed unit is ready to install, pressure-and leak-tested, and comes complete with a flexible stainless steel hose and mounting bracket with adjustable hub. FlexHead®3" Bend Radius per UL Guidelines (2 Bends Sh, FlexHead®Shown with 3 Bends Q ---�� 3 . ,Rt. -?, , '' iie-jx# ,orki ""01 r Atk , _ , . , , .. . ..::. . .,.:, .. .,..,. ‘ .....: , ? :... 1 1 ,..; 'IP' \ ▪ :. 4 " q.1 1,1,E p i,•p (i.,: ▪ , Pry , 11 //•, _ Z • .� FLEXHEAO 12 INDUSTRIES 2� www.flexhead.com ._sAo. HOSE SPECIFICATION SHEET itt20XX,20XXHH,,&220XXTSERIES 20XXE,20XXoHE.&Q20XO<SERIES )/11 3.0 1"-11.5NPT 1"-11THRE.5NPTAD THREAD 3.0 1 Fi s L±20mm L±20mm 2 01.31 - [33.4 I/2'NPT OR 3/4"NPT 1, I 1.5 FEMALE THREAD-1 11 I I 6.3 --) SEE CH CH ARTT— .-2.25 MODEL# "Hose Assembly(L)Length Inches(mm)" "Drop""D""Size(Inches)" 2024E/2024HE 24(610) 2036E/2036HE 36(914) 2048E/2048HE 48(1219) 1.5,3.0,&4.0 2060E/2060HE 60(1524) 2072E/2072HE 72(1828) 2024E 24(610) 2036ET 36(914) 2048ET 4811219) 5.71 2060ET 60(1524) 2072ET 72(1829) 13 800.829.6975 We invented the concept of flexible fire protection' .q„ BRACKET SPECIFICATION SHEET Multiport Design (For use with T-bar and Adjustable Design (For use with T-bar, Metal Stud Applications) Metal Stud and Chicago Grid Applications): standard sizes are 16", 24", 30" and 48" long Model # MP024BKT2 Model #AD016BKT2,AD024BKT2, ADO3OBKT2, AD048BKT2 OVERALL LENGTH 16",24",39:9'.OR 491 8".12",15',OR 24" R'1 y' r� � 1 = - 9i III &r,16.7,22.7',OR 40.7` —NOT SONFIC,; AD016:16M1-233'L ADO2t/30.f6%1 5.f L ADO48:OD)SO'L OPEN HUB DESIGN BOLT 93/B'164109 1 1,1 Multi-Position Tall Bracket(For use with T-bar,Wood and Metal Studs):Standard sizes are 14.5", 16" and 24" long. Model #ADJT24BKT1 241n 14.5" 16" 24" FLE 14 INDUSTRIES"L� www.flexhead.com -A FLEXHEAD° COMMERCIAL PRODUCTS _ _o t. lf a:4 24",36"48';60,72"hose lengths, 24,36",48;60,72"hose lengths. Rated working pressure 175psi,optional 300psi. Rated working pressure 175psi,optional 300psi. Straight model, Elbow model. Standard 1"I.D.,optional 11/4"I.D. be 24"Multiport Bracket for T-bar Grid or Metal 16"/24"/30"/48"Adjustable Bracket for Stud applications. T-bar Grid,Chicago Grid or Metal Stud applications. Model#:MP024BKT2(standard bracket) Model#s:AD016BKT2/AD024BKT2/ADO3OBKT2/ ADO48BKT2 I Hat Channel Bracket System for Metal Stud or 24"Multi-Position Tall Bracket Hat Channel applications. Model#:ADJT24BKT1 Model#:ADO24BKT2 with BKT-HTA 'FN. .. , , ,,,, r t Bracket for Confined Space Armstrong®TechZone Ceiling Bracket Dry Pendent System for Freezer and applications having a concrete for use with Armstrong TechZone Cold Storage applications deck above the ceiling. Ceiling systems. Model #:20XX-DPS-UH01 Model#:UH-2 Available in 6"long. Model#: SPO6TZBKT2 FLEXHEAD 800.829.6975 INDf/STR,E52,f 15 -Aauoone We invented the concept of flexible fire protectionTM FLEXIBLE SPRINKLER HOSE FITTINGS USE EXAMPLES 11> h APPROVED APPROVED X ' it `, A s tp Suspended Ceilings Exhaust Ducts ® ~ APPROVED APPROVED ) 44> ' ) r _1 I' ik `— _.—i b V. Institutional Cleanroom Ceilings Flexible Sprinkler Hose Fittings were developed to satisfy specific needs of the industry, save the industry millions in losses, provide superior seismic protection and promote the installation of sprinklers.They have been evaluated for use by both Underwriters Laboratory and FM approvals and are tested to approval standards that were independently developed by the testing laboratories. The first listing for a Flexible Sprinkler Hose Fitting was in 1990. 16 FLEXHEAD INDUSTRIES L'S w s h ww.flexhead.com WARRANTY FLEXHEAD® PRODUCTS LIMITED WARRANTY Flexhead Industries, Inc.warrants that its products will be free from defects in materials and workmanship under normal conditions of use and service when properly installed for a period of one year from date of sale. Our obligation under this warranty is limited to repairing or replacing any product that is returned to us with transportation charges prepaid within one year after the date of original sale and that our examination shows to our satisfaction to have been defective in materials or workmanship under normal conditions of use and service.The decision as to whether to repair or to replace any product shall be made by us,and any repair shall be made at our facility. Notwithstanding the foregoing,the following are specifically excluded from the coverage of this warranty: (a)Any product not manufactured by Flexhead Industries, Inc., including any sprinkler head(s)installed with or attached to a Flexhead Industries, Inc. product, provided, however, Flexhead Industries Inc. hereby assigns the right to enforce any original manufacturer's warranty of such product to the original purchaser of the Flexhead Industries, Inc. product(s). For the avoidance of doubt, Flexhead Industries, Inc.does not manufacture sprinkler heads and,therefore,does not warrant any such products. (b)defects resulting from ordinary wear and tear, including, without limitation,the replacement of the so-called poly bag components of any Flexhead Industries, Inc. product (c)products that have been altered in any manner by the buyer or by anyone other than Flexhead Industries, Inc. (d)products that have been subjected to misuse,abusive use,or damage by accident or casualty (e)products that have been installed or used in a manner contrary to our specifications, instructions or recommendation (1) products that have been installed or used in a manner that is not in compliance with all applicable requirements of any code, law, regulation or rule of any federal,state or local governmental or industry authority;and (g)products that have not been inspected and maintained in accordance with our specifications, instructions or recommendations, including, without limitation,our recommendations as to following the inspection and maintenance standards published by Factory Mutual Research Corporation(FMRC)and the National Fire Protection Association (NFPA); and (h)products that have been affected by Microbiologically Influenced Corrosion(MIC). This warranty is not assignable and shall benefit only the original purchaser of a Flexhead Industries, Inc. product. If any provision hereof or any portion of any provision shall be held invalid,the remainder of this Limited Warranty shall not be affected thereby,and all provisions of this Limited Warranty shall remain valid and in full force and effect to the fullest extent permitted by law.THIS WARRANTY IS IN LIEU OF ALL IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,WARRANTIES OF MERCHANTABILITY AND WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. NOTWITHSTANDING ANY PROVISION TO THE CONTRARY HEREIN OR ANY APPLICABLE LAW TO THE CONTRARY, IN NO EVENT SHALL FLEXHEAD INDUSTRIES, INC. BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES UNDER ANY CIRCUMSTANCES WHATSOEVER,WHETHER ARISING FROM ANY BREACH OF THIS LIMITED WARRANTY OR OTHERWISE ARISING FROM OR IN CONNECTION WITH THE USE OR OPERATION OF,OR ANY DEFECT IN,ANY FLEXHEAD INDUSTRIES, INC. PRODUCT, OR OTHERWISE.The risk of damages from any breach of warranty with respect to injury to any person will be born by the purchaser of Flexhead Industries, Inc. product. FLOCHEACi 800.829.6975 INousr 17 _�aumre We invented the concept of flexible fire protection' NOTES FLEXHEAD INDUSTRIES20 www.flexhead.com NOTES FLExiimis 800. 29.6975 INDUSTR?ES'1.. 19 8 i s6\aumwe 56 Lowland Street Holliston, MA 01746 PHONE/ 508-893-9596 TOLL FREE/ 800-829-6975 wwwflexhead.com • qc1 ed UNISTRUT' a +' i`nkore" TUBE CONOUR' AFC �9 INDUSTRIES' - Heritag@Plastics" FITTINGS Columbia-MBF" cope® I RIdge : 8� �o": ? n �� ,�---n • ., u- POWER-STRUT' Dom. 6prinkFLEX' t� icAF�c-cI' SCI AC9r Unlp�b' ...d....w.... d!EB.PMMONEReYt �.2017 Atkore International,Inc.All rights reserved.FXH-L-4005-1707 Pipe Clamps TOLCO" Fig. 22- Hanger for CPVC Plastic Pipe Single Fastener Strap c®us Size Range: 3/4'(20mm)thru 2'(50mm)CPVC pipe Material: Pre-Galvanized Steel C Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems.The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Fig. 22 can be installed on the top of a beam, but in this situation acts as a guide to the � piping which is supported by the beam itself. It is not intended to support >Lp. CPVC pipe from under a flat horizontal surface, such as a ceiling. Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada (cUL)to support fire sprinkler piping. May be installed in wood using \ fasteners supplied with product,or into minimum 20 gauge(o.smm)steel using (1) 1/4'x 1'tek type screw. Meets and exceeds the requirements of NFPA 13, l 13R and 13D. A J Features: Fig. 22 incorporates features which protect the pipe and ease B installation. The flared edge design protects CPVC pipe from any rough surface. It iseasily attached to the building structure he ctu using thespecial UL Listed hex head self threading screw*furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer)are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Part number and CPVC pipe size. * Hardened hex head self threading screw is furnished with the 's`' product and is the minimum fastener size acceptable. CPVC Max.Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) lbs. (kg) 0 22-3/4 3/4" (20) 27/16" (61.9) 15/16" (33.3) 13/16" (30.2) 51/2 (1.671 5/16" (7.9) 9 (4.1) n 22-1 1" (25) 211/16'(68.3) 17/16" (36.5) 131i6' (30.2) 6 (1,83) 5/16" (7.9) 9 (4.1) m v 22-11/4 11/4" (32) 31/16" (77.8) 15/8" (42.3) 13/16" (30.2) 61/2 (1.98) 5/16" (7.9) 11 (5.0) w 22-11/2 11/2" (401 35/18" (84.1) 13/4" (44.4) 13/16" (30.2) 7 (2.13) 5/16" (7.9) 12 (5.4) ., 22-2 2" (50) 33/4" (95.21 21/8" (54.6) 13/16" (30.2) 8 (2.44) 5/16" (7.9) 15 (6.8) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 96 B-Line series Pipe Hangers&Supports Pipe Clamps TOLCO'' Fig. 22L2- One Hole Hanger/Restrainer for CPVC & Steel Pipe cO is Size Range: 3/4"(20mm)thru 2' (50mm)CPVC&steel pipe MEC Material: Pre-Galvanized Steel Function: cULus Listed to perform as a hanger and restrainer for CPVC or IPS piping systems.The innovative design also allows for a preferred installation i'r"• C location close to a CPVC fitting without applying damaging compression forces ' on the pipe which could result in serious Mechanical ESC(Environmental \ Stress Cracking). A i Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada (cUL)to support fire sprinkler piping. May be installed in wood using -� fasteners supplied with product, or into minimum 20 gauge (0.9mm)steel using — (1) 1/4'x 1'tek type screw. Meets and exceeds the requirements of NFPA 13, ..:-.1-- . .) 13R and 13D. Installation Note: Comes in open position for easier installation. Because of multi-structural installation possibilities,specific fastener not included; see II notes below for various applications. li For Concrete Installation—UL requires a minimum test load of 340 lbs. (1.5kN) for CPVC hangers and 750 lbs. (3.3kN)for steel pipe hangers;verify anchors meet or exceed these requirements. 1 For Wood Installation—Test results have shown that #14 x 11/2" wood B screws will support the required load for c UL us. or SteelInstallation—Test results have shown that 1/4"x 1" (min. 20ga N. steel)Tek type screw will support required UL load. / . �. Finish: Pre Galvanized • Order By: Part number '..1,; Patent Pending ' - r ' 1 Mounting ---+ r--- Surface r se 1 Tab Down l Hanger/Restrainer or Tab Up k_____q 11 i Sprinkler I Head pe ; Offt Design Hanger/Restrainer Fitting -. OD A. CPVC or Steel Max.Hanger Max.Hanger Approx. Pipe Size A B C Spacing-CPVC Spacing-Steel Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 22L2-3/4 3/4" (20) 23/16" 155.6) 15/16' (23.8) 3/4" (19.0) 51/2 (1.67) NA (NA) 9 (4.1) 22L2-1 1" (25) 21/2" (63.5) 11/8" (28.6) 3/4" (19.0) 6 (1,83) 12 (3.66) 9 (4.1) 22L2-11/4 11/4" (32) 213/16"(71.4) 11/4" (31.7) 3/4' (19.0) 61/2 (1.98) 12 (3.66) 11 (5.0) 22L2-11/2 11/2" (40) 31/8" (79.4) 17/16" (36.5) 3/4" (19.0) 7 (2.13) 15 (4.57) 12 (5.4) 22L2-2 2" (50) 39/16" (90.5) 16/8" (41.3) 3/4' (19.0) 8 (244) 15 (4.57) 15 (6.8) AM dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers&Supports 97 Eaton Pipe Clamps TOLCO''Fig.23- Hanger for CPVC Plastic Pipe Double Fastener Strap UL us LISTED Size Range: 3/4'(20mm)thru 3'(80mm)CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Fig. 23 can be installed on the top, bottom or side of a beam. Approvals: Underwriters Laboratories Listed in the USA(UL) ' and Canada Call)sizes 3/4"(20mm)thru 2-(50mm)to support fire i / sprinkler piping. May be installed in wood using fasteners supplied ,\ ,) with product, or into minimum 20 gauge(0.9mm)steel using (2) 1/4"x 1'tek type screw. Meets and exceeds the requirements I t of NFPA 13, 13R and 13D. „ „ �" " Features: Fig. 23 incorporates features which protect the pipe �� \_; B and ease installation.The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building '` B A structure using the two UL Listed hex head self threading screws" C furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer)are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Part number and pipe size " Hardened hex head self threading screw is furnished with the • product and is the minimum fastener size acceptable. fr-., CPVC Max.Hanger Fastener Hex Approx. • Pipe Size A B C Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) i 23-3/4 3/4' (20) 31/8" (79.4) 19/16" (39.7) 13/16' (30.2) 51/2 (1.67) 5/16" (7.9( 9 (4.1) 1 23-1 1" (25) 33/8" (85.7) 111/is' (42.9) 13/16" (30.2) 6 (1,83) 5/16' (7.9) 9 14.1) ra'` 23-11/4 11/4" (32) 43/1s'(106.4) 23/32' (53.1) 13/16' (30.2) 61/2 (1.981 5/16" (7.9) 11 (5.0) 23-11/2 11/2" (40) 47/16"(112.7) 27/32" (56.3) 13/16" (30.2) 7 (2.13) 5/16" (7.9) 12 (5.4) 23-2 2" (50) 47/8" (123.8) 27/16" (61.9) 13/16" (30.2) 8 (2.44) 5/16" (7.9) 15 (6.8) 23-21/2 21/2' (65) 53/8" (136.5) 211/16" (68.3) 13/16" (30.2) Consult Factory 5/16" (7.9) 22 (10.0) 23-3 3' (80) 6" 1152.4) 3' (76.2) 13/16" (30.2) Consult Factory 5/18' (7.9) 25 (11.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 98 B-Line series Pipe Hangers&Supports Pipe Clamps TOLCO"" Fig.24- Hanger for CPVC Plastic Pipe Double Fastener Strap Side Mounted c0 us LISTED Size Range: 3/4'(20mm)thru 2'(50mm)CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in C ,-" automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA(UL)and 1 Canada(cUL)to support fire sprinkler piping. May be installed in wood using --__ fasteners supplied with product, or into minimum 20 gauge (0.912mm)steel using (2) 1/4'x 1'tek type screws. Meets and exceeds the requirements of H% NFPA 13, 13R and 13D. i. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from ,/ -," any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket O attachment be used as installation tools. No impact tools(such as a hammer) are allowed. Damage has been known to result from installations using B impact type tools. No pre-drilling of a pilot hole in wood is required. ��` Finish: Pre-Galvanized A B`. Order By: Part number and pipe size Hardened hex head self threading screw is furnished with the .. product and is the minimum fastener size acceptable. r ) .: 4 CPVC Max.Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) k. (m) in. (mm) Lbs. (kg) y 24-3/4 3/4" (20) 25/16" (58.7) 15/32" (27.8) 13/16" (30.2) 51/2 (1.67) 5/16" (7.9) 9 (4.1) E 24-1 1" (25) 25/8" (66.7) 15/16" (33.3) 13/16" (30.2) 6 (1,83) 5/16" (7.9) 9 (4.1) 0 24-11/4 11/4" (32) 3" (76.2) 11/2" (38.1) 13/16" (30.2) 61/2 (1.98) 5/16" (7.9) 11 (5.0) a 24-11/2 11/2" (40) 31/4" (82.5) 15/8" (42.3) 13/16" (30.2) 7 (2.13) 5/16" (7.9) 12 (5.4) 24-2 2" (50) 311/16"(93.7) 127/32" (43.6) 13/16" (30.2) 8 (2.44) 5/16" (7.9) 15 (6.8) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers&Supports 99 Eaton Pipe Clamps TOLCO" Fig.25 - Surge Restrainer Size Range:-One size fits 3/4'(20mm1 thru 2' (40mm) pipe. COUS LISTEDMaterial:-Pre-Galvanized Steel Function:-Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity.The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National111.41 Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals:—Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA(UL)and Canada(cUL). Finish: Pre-Galvanized Order By: Part number and band hanger, size from 3/4' (20mm)thru 2' 140mm). Patent#5,344,108 Approx.Wt./100 Part No. lbs. (kg) 25 4.8 (2.2) , „ • s, ,, „ „„ ,„„, ..,„ „ �x 11 l „„ „,,„ All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 100 B-Line series Pipe Hangers&Supports Pipe Clamps TOLCO"a Fig.27B - Speed Nut Size Range:—Fits screws supplied with all CPVC hangers. Material:—Pre-Galvanized Steel Finish:—Pre-Galvanized Function:—To be used anywhere a screw cannot achieve full embedment due to (`J , , thickness of wood structural material when installed. Fig. 27B allows full pull out load capacity of screws when installed to the standard screws supplied with all CPVC /9. hangers(Fig. 22, 23, 24, 28,28M, 29,and B3184). 4>,- Approx.Wt./100 Part No. lbs. (kgl 278 1.2 (0.5) "� Fig.27B (1)Required High 11 -11 Fig.27B Side of Hanger i (2)Required rT Application —\\ii ,I az -�`♦ ' \- fftft ' , Ss I __ fS-,"- u—y IL.L Hanger Application Hanger and Restraint Application N o. �.: .=may i / 1 , �I I II ' 1 r frT al 1 ` )1; ' \ -, , a\` 'fr � Fig.276 v 'd,. " `' ` ''�i (2)Required c 11 `. Fig.27B ` 'l��/��)I1 f `\,^ 1: (1)Required High Side of `\� c, ' Hanger Application \4 I I I I I I I ll—y Hanger Application Hanger and Restraint Application All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers&Supports 101 Eaton Pipe Clamps TOLCOr" Fig.28- "Stand-Off" Hanger& Restrainer for CPVC Plastic Pipe IING®es Size Range:—3/4' (20mm)through 2"(50mm) US=N liiMaterial:—Steel, Pre-Galvanized ' Function:—Designed to be used as a hanger and restrainer for CPVC piping where / Iff1146441 the 'stand-off'design will ease installation by eliminating the need for wood blocking. Features: 1 • • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. 1 • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. • The'Stand-Off"design eliminates the need for wood block extension. A • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. B • Attaches easily to wood structure with two hex head self-threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5h8'(7.9mm)extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge(1.024mm)with(2) 1/4'x 1'tek type self drilling r tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals:—Underwriters Laboratory Listed in the USA(UL)and Canada (cUL)to ( .';,,,, t. support automatic fire sprinkler systems. May be installed into wood using fasteners j supplied with product, or into minimum 18 gauge steel using (2) 1/4'x 1'tek type '..... screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies (4. the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8' (9.5mm)composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by:—Part number and pipe size. Pat. #7,455,268, Pat. #7,832,248 �\ b • /44 N Fig.276 (1)Required High Fig,27B ���I Side of Hanger (2)Required ��I `i Application 41 n l .- ! [ z__ , .. , . � 1 7 I Hanger Application Hanger and Restraint ., !'' Application _ ,- � rigs' Pipe Size A B C Approx.Wt./100 Part No. in. (mml in. (mml in. (mm) in. (mm) Ms. (kg) 28-3/4 3/4" (20) 31/32" (77.0) 2" (50.8) 31/2" (88.9) 18 (8.1) 28-1 1" (25) 35/16" (84.1) 23/16" (55.6) 31/2" (88.9) 21 (9.5) • 28-11/4 11/4" (32) 35/e' (92.1) 23/3" (60.3) 31/2" (88.9) 23 (10.4) 28-11/2 11/2" (40) 4" (101.6) 21/2" (63.5) 31/2' (88.9) 31 (14.0) 28-2 2" (50) 41/2" (114.3) 211/Is" (68.3) 35/8" (92.1) 34 (15.4) • All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 102 B-Line series Pipe Hangers&Supports g Pipe Clamps TOLCOTM' Fig.28M - Offset Hanger& Restrainer for CPVC Plastic Pipe Size Range: 3/4'(20mm)thru 2'(32mm) C UL US Material: Steel, Pre-Galvanized us7Ea Function: Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces • Unique snap-on design holds pipe firmly in place and allows retrofit type of installation •The "Stand-Off" design eliminates the need for wood block extension A •Can be installed on horizontal or vertical piping regardless of mounting surface orientation •Attaches easily to wood structure with two hex head self-threading screws furnished with product • Installs easily using rechargeable electrical driver with 5/16" (7.9mm) extension socket eliminating impact tool damage to pipe •Attaches easily to steel, minimum 18 gauge 11.024mm)with (2) 1/4" x 1"tek type self I' lirtiki I _ drilling tapping screws C •cULus Listed as a hanger and a restrainer for fire sprinkler piping Installation Note: When installed in wood structural members and threads from the B #10 x 1'screws are exposed, use Fig. 27B speed nut to secure Approvals: Underwriters Laboratory Listed in the USA(UL)and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig.28M satisfies the UL vertical . restraint requirements where needed. Fig.27B Order By: Part number and pipe size (2)Required Patent#7,744,042 :t • 42,24*A°b t ,i 1 r . 1 (--Ti-- Hanger and Restraint a a II _ J Application •d _ F---t II •.1 1 r -i da Fig.278 a t (1)Required �T __J ; - High Side of Hanger • r 5 Restraint r i I `c f + 1 Restraint Detail A Hanger Application Pipe Size A Hole Dia.B C Max Spacing" Approx.WL/100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 28M-3/4 3/4' (20) 2' (50.8) 3/16" (4.8) 35/I6" (84.1) 5'-6" (1676) 9 (4.1) 28M-1 1' (25) 21/6" 154.0) 3/16" (4.8) 31/2" (88.9) 6'-0" (1829) 12 (5.4) 28M-11/4 11/4" (32) 25/I6' 158.7) 3/Is' (4.8) 31/2" (88.9) 6'-6" (1981) 13 15.9) 28M-11/2 11/2' (49) 27/Is" (61.9) 3/16" (4.8) 37/e' (98.4) 7'-0" (2133) 14 (6.3) 28M-2 2" (50) 25/8" (66.7) 3/I6' (4.8) 47/16" (112.7) 8'-0" (24381 15 (6.8) * Required per NFPA 13 for CPVC plastic pipe All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers&Supports 103 Eaton Pipe Clamps TOLCO' Fig.29- Double Offset Hanger& Restrainer for CPVC Plastic Pipe c as Size Range: Available in 3/4'(2omm)and 1' 125mm) pipe sizes 1.5"(---,,,__,„ ul�N Material: Pre-Galvanized Steel (38.Imm) Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2" (20mm)x 11/2" (20mm)from mounting surface.This design \ _ will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. 1.5" ,p `G® (38.1mm) Features: r •Thumb tab provides protection to restrain pipe in rough job site conditions.Tab is not ae © 1 required to be bent for listed installation. o •Offset edge eliminates abrasion. o •Attaches easily to wood structure with two special#10 x 1" hex head self-threading screws furnished with product. o •Can be used as a single offset hanger by aligning 'dimples"with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada (cUL)as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre-Galvanized Order By: Part number and pipe size. Patent#US2008/0129040A1 A> ,h; a o f 0 Pipe Size Approx.Wt./100 o Part No. in. (mm) lbs. (kg) y_ . . © Q 29-3J4 3J4 (20) 11.0 (7.7) 474214 Minim) 29-1 1" (25) 18.6 (8.4 wil ) 1.5" ---,1.7 '\ 138.1mm) - - 0 m m et ® m m ®®m m -^ L Double Offset Single Offset Install using a rechargeable electric drill fitted with a 5/16" (7.9mm)socket attachment with the special hex head self-tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger/restrainer function. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 104 B-Line series Pipe Hangers&Supports Pipe Clamps B3184 - Offset Hanger for CPVC Plastic Pipe and IPS Pipe Size Range: 3/4" (20mm)thru 2' (32mm1 Material: Pre-Galvanized Steel Function: Designed to be used as a hanger for CPVC piping or steel piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Pipe Size Features: \ • Flared edge design protects CPVC pipe from any rough or abrasive surfaces 0 •The "Stand-Off" design eliminates the need for wood block extension ' • Can be installed on horizontal or vertical piping regardless of mounting ," J, surface orientation / / •Attaches easily to wood structure with two hex head self-threading \ -- screws furnished with product a H r Installation Note: When installed in wood structural members and threads a� from the#10 x 1'screws are exposed, use Fig. 27B speed nut to secure H L - Order By: Part number and pipe size �� . lir ' fill% • CPVC H L Max.Hanger Fastener Hex Approx. Pipe Size Overall Overall Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) St. 1m) in. (mm) Lbs. (kg) B3184-3/4 3/4" (20) 29/16" (65.1) 41/4" (107.9) 51/2 (1.67) 5/is" (7.9) 9.0 (4.1) B3184-1 1" (25) 213/16" (71.4) 41/2" (114.3) 6 (1,63) 5/16" (7.9) 10.0 (4.5) B3184-11/4 11/4" 132) 33/16" (81.0) 45/8" (117.5) 61/2 (1.98) 5/16' (7.9) 12.0 (5.4) B3184-11/2 11/2' (40) 37/16" (87.3) 5" (127.0) 7 (2.13) 5/16" 0.9) 12.0 (5.4) B3184-2 2" (50) 37/8" (98.41 5" (127.0) 8 12.44) 5/16" (7.91 15.0 16.8) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers&Supports 105 Eaton RING HANGERS i . nn47 Fig. 69 (Formerly Afcon Fig.300) Adjustable Swivel Ring,Tapped Per NFPA Standards Size Range:'/2"through 8" ar Material:Carbon steel Finish:Strap is Pre-Galvanized Zinc Material. Nut is Zinc Plated. Service:Recommended for suspension of non-insulated stationary pipe line. Maximum Temperature:450"F Approvals:Complies with Federal Specification A-A-1192A(Type 10), WW-H-777-E(Type 10), ,s and ANSI/MSS SP-58(Type 10).UL Listed and FM Approved(Sizes3/4"-8"). Features: • '/2'-2"sizes designed for use with steel and CPVC piping and manufactured with I FBC System Compatible oil. 1 • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the 1/2"through 6"sizes.The capture is permanent in the bottom \ is' portion of the band,allowing the hanger to be opened during installation if desired,but not allowing the nut to fall completely out. '/z"through 2"Size Ordering:Specify size,figure number and name. - --A Rounded Edge Design Non-captured nut also available upon request. -.IA 1.- - A r- II 6 VL us FM F LISTED APPROVED of>t C B �1 I� F 6 I F B C 1 0 ..r1 } ii l G �� G G '/2"through 1"pipe 1 1/4"through 2"pipe 2'/2"through 8"pipe e FIG. 69: DIMENSIONS (IN) • LOADS (LBS) • WEIGHT(LBS) Pipe Size Max Load Weight Rod Size B C F G '„; A Width 1/2 0.10 2'/8 2 19/6 3/4 0.10 23/4 11/45 15/6 1 0.10 29/,6 111/s 1 5 11/4 300 0.10 2% 13/4 T/e 7s 11/2 0.10 3/8 23/4 1% 2 0.11 3'/4 2% 1'/e a. 2' 525 0.20 4 23/4 15/6 "a` 3 0.20 313/6 215/6 13/16 4 650 0.30 41t/is 313/8 19/6 3/a --. ''' 5 0.54 1 55's 433/a 21/2"through 8"Size 6 1,000 0.65 h 6 /6 5/6 2% 8 1.00 89/,s 79/s 31A PROJECT INFORMATION APPROVAL STAMP Project: DApproved Address: D Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.18 Strut Systems The B-Line series metal framing support system is designed with many ht , time-saving features. Fully adjustable and reusable, with a complete line of a= channels, fittings, and accessories for multi-purpose applications. y �, `Y 4 ',r 1,: SELECTION CHART / /� for Channels, Materials and Hole Patterns y M Material&Thickness Channel Hole Pattern o M 3 m Channel Dimensions w Stainless SH S H17/a TH KO6 o 3 Steel Height Width Type Type Channel Steel Alum. 304 316 - I p q r U is e B11 31/4' (82.51 15/8" (41.3) 12 Ga. — — — .1 1 � 1 — 1 B12 27/16" (61.9) 15/8" (41.3) 12 Ga. .105 — — 1 2 1 1 2 — 1 2 622 15/a" (41.3) 15/e" 141.3) 12 Ga. .105 12 Ga. 12 Ga. 12 2.4 1 122 4 1 1 2 B24 15/8" (41.3) 15/a" 141.3) 14 Ga. .080 14 Ga. 14 Ga. 1 2 3 4 1 1 2 3 4 — 1 2 1326 15/8" (41.3) 15/a" (41.3) 16 Ga. — — — 1 1 1 — 1 632 13/8" 134.9) 15/e' (41.3) 12 Ga. — 12 Ga. — 1 3 1 1 3 - 1 1342 1' (25.4) 15/a' (41.3) 12 Ga. — 12 Ga. — 13 1 1 3 - 1 652 13/16" 120.6) 15/a" (41.3) 12 Ga. — — — 1 1 1 — 1 654 13/1s" 120.6) 15/a" (41.3) 14 Ga. .080 14 Ga. 14 Ga. 1 2 14 1 12 3 4 - 1 2 656 13/16" (20.6) 15/8" (41.3) 16 Ga. — — — 1 1 1 — 1 Channel Nuts B2000 Series `i Schedule 40 Pipe Clamps ..... 1-' / / �'� `, Part Nominal Mat'I No. Pipe Size Ga. Size and Part Number • B2001 3/8" (10) 16 Thread With Without Twirl B2008 1/2" 115) 16 Copper Tubing Clamps Size Spring Spring Nut DURA-COPPER'" B2009 3/4" 120) 14 1/4'-20 N224 N224W0 TN224 B2010 1" (25) 14 3/8'-16 N228 N228W0 TN228 Part Nominal Mat'I 62011 11/4" (321 14 1 No. Tubing Size Ga. B2012 11/2' 1401 12 /2"-13 N225 N225W0 TN225 s B2026DCU 1/2' 115) 16 132013 2" (50) 12 I /8'"-11 N255 N255W0 -- B2008DCU 3/4" )20) 16 3/4"-10 N275 N275W0 •- B2D14 21/2" (601 12 620300CU 1" (25) 14 132015 3' (80) 12 ' Available Finishes: Electro-Galvanized 62032DCU 11/a' (32) 14 B2016 31/2" (90) 11 B2011DCU 11/2" (40) 14 132017 4' (100) 11 B2038DCU 2" (50) 12 132018 41/2' 1115) 11 Combo Nut Washers g2042DCU 21/2" (so) 12 62019 5" 1125) 11 Part Thread B2046DCU 3" (80) 12 132020 6" 1150) 11 Number Size e' B2050DCU 31/2" (90) 12 132021 7" (175) 11 NW524 1/4"-20 Illikj-- B2054DCU 4' (100) 11 62022 8" 12001 11 NW528 3/a"-16 Available Finishes: Electro-Galvanized,Aluminum, Stainless, NW525 1/2"-13 DURA-COPPER Painted, Hot-Dip Galvanized and PVC coated. Nut and bolts are included with all two-piece clamps. Available Finishes: Electro-Galvanized **Add "PA"to Part No.for Pre-assembled All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 18 B-Line series Pipe Hangers&Supports Strut Systems Below are some basic clamp and cushions to be used with a strut system. For the industry's most complete line of strut and strut fittings, refer to B-Line series Strut Systems catalog. B2000 Series � =.VA �i tIiP BVT& BVP 101, �,I Seriesi�� i Vibra-Clamp y . � 1, . B1999 For Copper Tubing & OD Sizes 1 Vibra-Cushion"'" O.D. Pipe Clamps Catalog Copper& Nominal •Inhibits Galvanic Reaction 8 No. 0D Tubing Size Copper Size •Reduces Sound &Vibration d Part O.D.Size Marl 71 No. (Outside Dia.) Ga. BVT025 1/4" (6.31 - - •Used on refrigeration, HVAC, copper to E B2023 4" (6.3) 16 BVT037 3/8" (9.51 1/4' (6) tubing, glass pipes & hydraulic lines .' oo Bzoza 3/8' (9.5) 16 BVT050 1/2" (12.71 3/a" (10) Available in 20 Ft. rolls. en- B2025 1/2" (12.7) 16 BVT062 5/e" (15.9) 1/2" n5) For Pipe Rigid Conduit or Iron B2026 5/8" (15.91 16 BVT075 3/4" (19.0) 5/8" (17) 9 B2027 3/4' (19.0) 16 BVT087 7/8" (22.2) 3/4" (201 Nominal Length of Use B2028 BVT100 1" (25.41 - - Size Vibra-Cushion Clamp No. 7/8 (22.21 16 BVT112 11/8" (28.6) - 1" (25) 3/8' (10) 21/8" 154.01 B2002 B2029 1" (25.4) 14 BVT125 11/4" 131.7) - - 5 B2030 11/e" (28.6) 14 BVT137 13/a" 134.9) 11/4" (32) 3/4" (20) 31/4" (82.5) B2031 B2031 11/4" (31.7) 14 gVT150 11/2" 138.1) - - 1" B2032 13/a" (34.9) 14 (25) 41/8" (104.8) B2004 B2004 11/2. 138.1) 14 BVT162 15/8" (41.3) 11/2' (40) 11/4" (32) 53/16" (131.81 B2012 B2011 15/e' (41.3) 14 BVT175 13/4" (44.4) - - 11/2" (40) 515/16" (150.81 B2038 B2005 13/4" (44.4) 12 BVT187 17/8" (47.6) - - 2" (50) 71/2" (190.51 B2042 62036 17/8" (47.6) 12 BVT200 2" (50.8) - - 21/2' (65) 9" (228.6) B2046 62037 2" (50.8) 12 BVT212 21/8" (54.0) 2' (50) 3' (80) 11" (279.4) B2051 B2038 21/8" (54.0) 12 BVT225 21/4" (57.1) - - 31/2" (90) 121/2' (317.5) B2055 B2039 21/4" (57.1) 12 BVT250 21/2" (63.5) - - 4" (1001 141/2' (368.3) B2059 B2013 23/e' (60.3) 12 BVT262 25/8" (66.7) 21/2" (651 5" (125) 177/16" (442.9) B2067 B2041 21/2" (63.5) 12 BVT300 3" (76.2) - - 6" (150) 203/4' 1527.01 B2116 B2042 25/8" (66.7) 12 BVT312 31/s" (79.4) 3" (80) B2043 23/4" (69.8) 12 BVT362 35/8" (92.1) 31/2" (901 For Thinwall(EMT)Conduit 62014 27/8" (73.0) 12 BVT412 41/8" (104.81 4" (100) BVT612 61/8" (155.61 6" (150) Nominal Length of Use 62045 3" (76.2) 12 Size Vibra-Cushion Clamp No. B2046 31/8" (79.4) 12 Available for tubing and pipe sizes 3 13 B2047 31/4" (82.5) 12 1/4"to 6', OD sizes 1/4'to 65/e". /2" (15) 1 3/16" (58.7) B2027 B2048 33/8" (85.71 12 /" (15) 2 /6" (73.0) B2002 1 Easy one tool installation, dampens 3/4" (20) 27Ja' (73.0) B2003 B2015 3 /2' (88.91 12 vibration and noise, secures tubing 1" 125) 35/s' (92.1) B2032 B2050 35/a" (92.1) 11 firmly, and protects against galvanic 11/a' (32) 43/8" (120.6) B2036 B2051 33/4' (95.2) 11 reaction. 11/2" (401 57/16" (138.11 B2012 B2016 4" (101.6) 11 2" (50) 67/8" (174.61 B2013 B2054 41/e" (1oas) 11 Stainless Steel available B2055 41/4" (107.9) 11 132056 43/8" (111.1) 11 For Thinwall (EMT)Conduit B2017 41/2" (114.3) 11 For Pipe Sizes Nominal Length of Use B2058 45/8" (117.5) 11 Size Vibra-Cushion Clamp No. B2059 43/4' (120.6) 11 Catalog Nominal 1/4" (61 13/16` (30.2) B2026 B2060 47/8" (123.8) 11 No. Pipe Size 3/8" (10) 18/16" (39.7) B2027 B2061 5" (127.01 11 BVP025 1/4" (61 1/2" (151 17/8" (47.6) B2028 B2062 51/8" (130.21 11 BVP037 3/8" (10) 5/8" (171 25/16" (58.7) B2029 B2063 51/4" (133.3) 11 BVP050 1/2" (15) 3/4" (20) 23/4' (69.8) B2030 B2064 53/8" (136.51 11 BVP075 3/4" (20) 1" (25) 31/2" (88.9) B2032 B2065 51/2" (139.71 11 BVP100 1" (25) 11/4' (32) 45/16" (109.5) B2011 BVP125 11/4" (32) 11/2" (40) 51/8" (130.2) B2036 BVP150 11/2" (40) 2" (50) 611/16' (169.9) B2013 BVP200 2" (50) 21/2" (65) 81/4" (209,5) 62014 BVP250 21/2" (65) 3" (801 913/16" (249.2) B2048 BVP300 3" (MD) 31/2" (90) 113/8' (288.91 B2052 BVP350 31/2" (90) 4" (1001 1215/16" (328.61 B2056 BVP400 4' (100) 5" (1251 61/8" (409.6) B2064 BVP500 5' (125) 6" (1501 191/4" (488.9) B2112 BVP600 6" (150) 8" (2001 251/2' 1647.71 B2128 All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers&Supports 19 Eaton Pipe Clamps -- • _.W--"'ram Ilk '..a,— ,..„.........,N,...4........."46'""... `f Pipe clamps offered in this section are designed for support and attachment of pipe to structural members. A wide range of pipe clamps are available for various applications. Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available. Finishes The standard finishes for mechanical supports are plain steel (oil coated) sometimes referred to as black and Electro- Galvanized Zinc(ASTM 8633 SC3). Hot-Dip Galvanized After Fabrication (ASTM A123), Red Primer, Plastic Coating, DURA GREEN", DURA-COPPER''and other special coatings are available upon request. Note: Due to the design of some products, (threads, connecting hardware, swivels, etc.) items may or may not be uniformly coated with special finishes. In some cases, the hanger itself may be coated, however, the hardware may be supplied Electro-Plated, Copper Plated, or in Stainless Steel. Recommended Torque (Pipe Clamp Hardware) 1/4"-20 5/16"-18 3/6"-16 1/2"-13 5/6"-11 3/4"-10&larger 6 ft/lbs(8 Nm) 11 ft/lbs(19 Nm) 19 ft/lbs(26 Nm) 50 ft/lbs(68 Nm) 65 ft/lbs 188 Nm) 75 ft/lbs(101 Nm) Approvals(as noted) Items in this section are Underwriters Laboratories Listed, Factory Mutual Approved, and comply with Federal Specification \MN-H-171 E &A-A-1192A or Manufacturers Standardization Society ANSI/MSS SP-69& SP-58. All pipe hangers and supports in this section are sized to fit schedule 40/80 pipe unless otherwise noted. Some steel items may be specially fabricated to fit other pipe diameters i.e. ductile iron, cast iron, etc. Select pipe O.D. from charts on pages 321 thru 325. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 72 B-Line series Pipe Hangers&Supports Pipe Clamps B3373 - Standard Riser Clamp B3373F- Felt Lined Standard Riser Clamp for Copper Tubing (not UL Listed or FM Approved) B3373C - PVC Coated Standard Riser Clamp (not FM Approved) Size Range: (B3373) 1/2"(15mm)thru 30" (760mm)pipe (B3373F) 1/2'115mm)thru 21/2" (65mm)copper tubing (B3373C) 1/2' (15mm)thru 6' (150mm) pipe C UL US LISTED Design Load Material: Steel APPROVED Insulation Material: (B3373F) 1/6" (3.2mm)thick felt. Function: Used for supporting vertical piping. I, ) Approvals: Underwriters Laboratories Listed in the USA(UL), Canada (cUL) l '''S 3/4(20mm)-8' (200mm). ‘ � Factory Mutual Engineering Approved (FM)for plain and electro-Galvanized zinc, 1' � 3/4" (20mm)thru 8' (200mm). Conforms to Federal Specification VWV-H-171 E& A-A-1192A, Type 8 and Manufacturers Standardization Society ANSI/MSS SP-69& Bolt Size SP-58, Type 8. H �� Maximum Temperature: 650°F (343°C) ' L Finish: Plain. Contact customer service for alternative finishes and materials. Order By: Bolts and Nuts Included (83373 and B3373C) pipe size and finish. B3373F is available for Iron Pipe Size, consult factory. k fr B3373C Iv '' B3373F 83373 Pipe Size L Design Load Approx.Wt./100 Part No. in. Imm) in. (mm) Bolt Size Lbs. IkNI Lhs. (kg) 83373-1/2 1/2" (15) 81/2" (215.9) 3/8"-16x11/4" 255 (1.13) 101 (45.9) 83373-3/4 3/4" (20) B3/4" (222.2) 3/8"-16 x11/4" 255 (1.13) 105 (47.7) Notes: For ductile iron (0.1.)pipe use part B3373-1 1" (25) 91/16" (230.2) 3/8"-16x 11/4' 255 (1.13) 109 (49.4) numberB337301-pipe B3373-11/4 11/4' (32) 91/2' (241.3) 3/8"-16x 11/4' 255 (1.13) 112 (50.9) size.Contact B-Line 83373-11/2 11/2' (40) 93/4' (247.6) 3/8"-16x11/2" 255 (1.13) 113 151.1) Engineering for more B3373-2 2" (50) 101/4" (260.3) 3/8"-16x11/2" 255 (1.13) 165 (75.0) information. Pli B3373-21/2 21/2" (65) 1115/16' (303.2) 3/8"-16x11/2' 390 (1.73) 180 (81.6) E B3373-3 3' (80) 117/16" (290.8) 3/8"-16x11/2" 530 (2.35) 195 (88.4) um B3373-31/2 31/2" (90) 123/8' (314.3) 1/2"-13x 13/4" 670 (2.98) 217 (98.5) a 'a B3373-4 4" (100) 127/8' (327.0) 1/2"-13x 13/4' 810 (3.60) 228 (103.5) 83373-5 5" (125) 133/4" (349.21 1/2"-13x13/4" 1160 (5.16) 480 (217.7) B3373-6 6" (150) 143/4" (374.6) 1/2"-13x2' 1570 (6.98) 526 (238.6) B3373-8 8" (200) 173/4" (450.81 5/8"-11 x21/2" 2500 (11.12) 957 (434.1) 83373-10 10" 1250) 197/16" (493.71 5/8'-11 x21/2- 2500 (11.12) 1101 (499.4) B3373-12 12" (300) 2111/16" (550.9) 5/8"-11 x3" 2700 (12.01) 1622 (735.7) B3373-14 14" (350) 238/16' (598.51 5/8"-11 x3" 2700 (12.01) 1732 (785.6) B3373-16 16" (400) 263/8' (669.91 3/4"-10x31/4" 2900 (12.90) 2959 (1342.2) B3373-18 18" (450) 287/8" (733.4) 3/4'-10x31/4° 2900 (12.90) 3235 (1467.4) B3373-20 20" (500) 303/4 (784.2) 3/4'-10x31/2" 2900 (12.90) 3568 (1618.4) B3373-24 24" (600) 347/8" 1'15.81 3/4"-10x31/2" 2900 (12.90) 4064 (1843.3) B3373-30 30" (750) 403/4" (1035.01 7/e-9x31/2" 2900 (12.90) 6016 (2728.8) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers&Supports 73 Eaton Hangermate®+ Rod Hanging Anchors for Wood CATALOG NUMBER DESCRIPTION SAMMYS®MODEL# HANG ROD SIZE QTY MSTR QTY Hangermate+For Wood-Vertical PFM2251000 1/4"x 2" GST 200 Vertical 1/4" 25 125 PFM2251050 1/4"x 1" GST 10 Vertical 3/8" 25 125 PFM2251100 1/4"x 2" GST 20 Vertical 3/8" 25 125 • ,�,_-�_�w u_ PFM2251150 5/16"x 2-1/2" GST 25 38D Vertical 3/8" 25 125 PFM2251200 1/4"x 3" GST 30 Vertical 3/8" 25 125 PFM2251250 1/4"x 4" - Vertical 3/8" 25 125 PFM2251300 5/16"x 2-1/2" GST 2 Vertical 1/2" 25 125 Hangermate+For Wood-Horizontal PFM2261000 1/4"x 1" SWG 200 Horizontal 1/4" 25 125 PFM2261050 1/4"x 1" SWG 10 Horizontal 3/8" 25 125 PFM2261100 1/4"x 2" SWG 20 Horizontal 3/8" 25 125 PFM2261150 5/16"x 2-1/2" SWG 25-380 Horizontal 3/8" 25 125 Hangermate+ Pivot For Wood-Angled Applications r. PFM2281100 1/4"x 2" SH-GST 20 Variable 3/8" 25 125 Hangermate+Suspender For Wood-Dual-Directional k". PFM2271000 5/16"x 2-1/4" - Vertical& 3/8" 25 125 Horizontal Hangermate+For Wood-Acoustical Ceiling Screw Eyelet PFM2251500 1/4"x 3" CWSD 15 Vertical& Eyelet Hole 25 125 Horizontal 3/16° The Complete Anchoring Solution-Installation Accessories and Tools CATALOG NUMBER DESCRIPTION HANGERMATE+ QTY MSTR OTY tF. w.. PFM2201150 Wood Socket Driver Rod Hanger 1 5 — PFM2201300 Suspender Driver Suspender 1 5 Or mask!, PFM2201250 Pivot Driver Pivot 1 5 "": - PFM2201350 Ceiling Screw Eyelet Driver Acoustical 1 5 GM PFM2201100 Pole Tool Kit Rod Hanger 1 5 fDCF6102S2 12V Max*Lithium Ion 1/4"(13mm)Screwdriver Kit ki DCD790D2 20V MAX*XR Lithium Ion Brushless Compact Drill/Driver Kit ,pi lDCD990M2 20V MAX*XR Lithium Ion Premium 3-Speed Drill/Driver Kit DCD995M2 20V MAX*XR Lithium Ion Brushless Premium Hammerdrill Kit 'Maximum initial battery voltage(measured without a workload)is 20 volts.Nominal voltage is 18. 5 Product Information II Illarl NOTE: Verify ALL material that comes in contact to CPVC Pipe with the Designer at Patriot Fire Protection - May not pertain to all projects. FS-ONE High Performance Intumescent Firestop Sealant - ` /7 Product description ■ Intumescent(expands when exposed to fire)firestop sealant that 4/401„,,, helps protect combustible and non-combustible penetrations for up to 4 hours fire rating �j Product features �x ■ Smoke,gas and water resistant after material has cured w� • Contains no halogen,solvents or asbestos i •;�, • High fire rating properties �� _.. • Water based,easy to clean Technical Data* FS-ONE • Protects most typical firestop penetration applications Chemical basis Water-based intumescent acrylic IN Paintable dispersion • Single component systems available Color Red • Meets LEEDTM requirements for indoor environmental quality credit Application temperature 40°F to 104°F(5°C to 40°C) 4.1 Low Emitting Materials,Sealants and Adhesives and 4.2 Paints Skin forming time Approx.20-30 min. and Coatings Curing time Approx.2 mm/3 days Areas of application Average volume shrinkage 24.1% • Steel,copper and EMT pipes (ASTM C1241) IIInsulated steel and copper pipes Movement capability Approx.5% • Cable bundles Expansion rate(unrestricted) Up to 3.5 times original volume • Closed or vented plastic pipes Temperature resistance(cured) -40°F to 212°F(-40°C to 100°C) ■ HVAC penetrations Surface burning characteristics Flame Spread:0 (ASTM E 84-96) Smoke Development:5 For use with Sound transmission classification 56(Relates to specific construction) ■ Concrete,masonry,drywall and wood floor assemblies (ASTM E 90-99) • Wall and floor assemblies rated up to 4 hours Approvals •California State Fire Marshal- No.4485-1200:108 Examples •City of New York-MEA 326-96-M Vol.IV IISealing around combustible pipe penetrations in fire rated Tested in accordance with construction •UL 1479 •ASTM E 814 •ASTM E 84 • Sealing around non-combustible penetrations in fire rated 'At 73°F(23°C)and 50% elative humidity construction ;fo,G FILL VOID OR OUGCANH YMATERIAL FOR USE IN THROUGH-PENETRATION ® Me U FIRESTOP SYSTEMS • r• gSSEE UL R RE RESISTANCE DIRECTORY ^"M rasaraa 6617 APPROVED Installation instructions for FS-ONE Notice 4. Smoothing of firestop sealant:To complete the • On materials where oil,plasticizers or solvents may • Before handling,read Material Safety Data Sheet seal,tool Immediately to give a smooth appearance. bleed I.e.Impregnated wood,oil based seals,green and product label for safe usage and health Excess sealant,prior to curing,can be cleaned away or partially vulcanized rubber information. from adjacent surfaces and tools with water. • In any penetration other than those specifically • Instructions below are general guidelines—always 5. Leave completed seal undisturbed for 48 hours. described in this manual or the test reports refer to the applicable drawing in the UL Fire 6. For maintenance reasons,a penetration seal could Resistance Directory or Hilti Firestop Systems Guide be permanently marked with an identification plate. Storage for complete installation information In such a case,mark the identification plate and • Store only in the original packaging in a location fasten it in a visible protected from moisture at temperatures between Opening position next to the seal. 40°F(5°C)and 86°F(30°C) 1. Clean the opening.Surfaces to which FS-ONE will Not for use • Observe expiration date on the packag be applied should be cleaned of loose debris,dirt, • High movement expansion joints oil,moisture,frost and wax.Structures supporting • Underwater penetrating items must be installed in compliance with local building and electrical standards. , W '.' a, �� Application of firestop sealant UI •.• ' 1 y 2. Install the prescribed backfilling material type endill depth to obtain the desired rating Of required.Leave -� sufficient depth for applying FS-ONE. `.r *,._. 3. Application of firestop sealant:Apply FS-ONE to the 1.clean opening. 2.Pack mineral wool. 3.Apply FS•ONE. 4.Smooth 5.leave completed 6.Fasten daNfkaton required depth In order to obtain the desired fire rating. OtreWl� Fs-ONE. Seel vrdtanrbed for pace(4 reapwatll, 4Shours. Make sure FS-ONE contacts all surfaces to provide maximum adhesion.For application of FS-ONE use a bulkstandardg caulking gun,foil pack gun,bulk loader and a LI''''' _bulk gun.With FS-ONE buckets,Greco type sealant pumps may be used.(Contact pump manufacturer fora f proper selection). 5la'li 1.Clean opening. 2 Pack mineral wool. 3.Apply FS-ONE. 4.Smooth 5.Leave completed 6.Fasten denliflcellan fit nWlmd) FS-ONE. seal undlsarbed for plate ill reputed). 48 hors. Hilti. Outperform. Outlast. 22 Hilti,Inc.(U.S.)1-800-879-8000•www.us.hilti.com•en espanol 1-800-879-5000•Hilti Firestop Systems Guide ~l`Tl Product information High-performance intumescent firestop ; sealant FS-ONE MAX Applications ■ For effectively sealing most common through penetrations in a variety I of base materials ■ For use on concrete,masonry and drywall • Mixed and multiple penetrations • Metal pipe penetrations:copper,steel and EMT • Insulated metal pipe penetrations:steel and copper ■ Plastic pipe penetrations:closed or vented Advantages r i ■ US-produced:"Buy American"compliant • One product for a variety of common through penetrations +' - �•;� ■ Cost-effective,easy-to-use solution ■ Water-based and paintable Technical data • Industry-leading VOC results Chemical basis Water-based acrylic dispersion • Ethylene glycol-free Approx.Density 84.3 Ib/ft, Color Red Application temperature range 41-104°F a Vets COSPamLE Approx.cure time', 4 mmj3 days rated Temperature resistance range -410 212°F Chemical Mold Mold and mildew Mold and mildew performance Class 0(ASTM G21-96) resistant resistant Mold and mildew resistance Yes 0 ® asv FI L VOID OR CAVITY MATERIAL B �F Surface burning characteristics Flame spread:0 o` p FOR USE IN THROUGH-PENERTATION UL 723(ASTM E84 FIRESTOP SYSTEMS ) Smoke development:10 C US SEE UL FIRE RESISTANCE DIRECTORY UL 1479,ASTM E814,ASTM E84, US APPROKa NYE Tested In accordance with CAN/ULC-5115,ASTM G21,ASTM E90 Intertek California State fire marshal approval CSFM Listing 4485-1200:0108 for FS-ONE MAX Intumescent Firestop Sealant Expansion ratio(unrestricted,up to) 1:5 "at 75°F/2.PC,50%relative humidity F41/LT1 . . ill. mix*E MA* Order Designation Package Content Item number FS-ONE MAX 20oz foil(3 case+dis)) 1x Foil pack dispenser manual CS 270-P1,75x Firestop sealant FS-ONE MAX 20 az foil 3530252 FS-ONE MAX 10oz tube(1 case) 12x Firestop sealant FS-ONE MAX 10 oz cartridge 3530249 FS-ONE MAX 5 gallon(18 pails) 18x Firestop sealant FS-ONE MAX 5 gallon pail 3530263 FS-ONE MAX 20oz foil(1 case) 25x Firestop sealant FS-ONE MAX 20 oz foil 3530250 FS-ONE MAX 20oz foil(3 cases) 75x Firestop sealant FS-ONE MAX 20 oz foil 3530251 FS-ONE MAX 20oz Foil-Pallet 600x FSONE-MAX 20 oz foil,290x Bulk Shipping Condition 3534713 FS-ONE MAX 10 oz cartridge 2101531 m FS-ONE MAX 5 gallon pail 2101533 C N Hilti. Outperform. Outlast. o 0 6 Hilt,Inc.(USA)1-800-879-8000 I www.us.hilti.com I en espanol 1-800-879-5000 I Hilt(Canada)Corp.1-800-363-4458 I www.hilti.ca FS-ONE MAX N n O en Before handling and for specific application details, refer to Hilti product literature, 3rd party published listings and national approvals. For industrial use only. s pL:i50 tr Avant toute utilisation et pour tout detail concernant une application,se referer a la documentation Hilti, a la lists N •l.+ Q R de publications des tierces parties et aux approbations nationales. Seulement pour utilisateurs professionnels. ❑ es Antes de usar y para detalles especfficos de aplicacion,vease la informaciOn que acompana al producto Hilti, el listado publicado por terceros y las aprobaciones nacionales. Solamente para los usuarios profesionales. UL: www.us.hlltl.com , ,, , , ww www.hlltl.ca I I n www.hiltl.comilk 0 © (f ° O 2h* tgio ilt �� *74 I( Nil IP 4 01) \ ?l 1 1 �•�/ , X- • I *2h @ 23°C(73°F)/50%r.H. Printed:01.08.2016 I Dec-Nr:PUB/5201285/000/02 11.4111 I MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 ® Page: 1 of 2 MATERIAL SAFETY DATA SHEET Product name: FS-ONE High Performance Intumescent Firestop Sealant Description: One-part acrylic-based sealant Supplier: Hilti, Inc. P.O.Box 21148,Tulsa,OK 74121 Emergency#(Chem-Trec.): 1 800 424 9300(USA,PR,Virgin Islands,Canada);001 703 527 3887(other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: PEL: TLV: STEL: Polyacrylate dispersion Mixture NE NE NE Calcium carbonate 001317-65-3 5 mg/m3(T) 10 mg/m3(T) NE Zinc borate 138265-88-0 NE NE NE Ammonium polyphosphate 068333-79-9 NE NE NE Talc 014807-96-6 20 mppcf 2 mg/m3 NE Expandable graphite 012777-87-6 5 mg/m3(T) 2 mg/m3(T) NE Ethylene glycol 000107-21-1 NE C:100 mg/m3(A) NE Polybutene 009003-29-6 NE NE NE Iron oxide 001309-37-1 10 mg/m3 5 mg/m3 NE Glass filament 065997-17-3 NE 5 mg/m3(T) NE Silicon dioxide 014808-60-7 0.05 mg/m3(T) 0.1 mg/m3(T) NE Water 007732-18-5 NE NE NE Abbreviations: PEL=OSHA Permissible Exposure Limit. TLV=ACGIH Threshold Limit Value. C =Ceiling. STEL =Short Term Exposure Limit. NE=None Established. NA=Not Applicable. (T)indicates"as total dust". (R)indicates"as respirable fraction". (A) indicates"as an aerosol". mppcf=million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor: Odorless. Vapor Density: (air=1) Not determined. Vapor Pressure: 23mbar @ 20C/68F Boiling Point: Not applicable. VOC Content: 75.0 g/L. Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Non-flammable. Flammable Limits: Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting None known.Use a self-contained breathing apparatus when fighting fires involving chemicals. Procedures: Unusual Fire and Explosion None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur Hazards: and phosphorous. REACTIVITY DATA Stability: Stable. Hazardous Polymerization: Will not occur. Incompatibility: Strong acids,peroxides,and oxidizing agents. Decomposition Products: Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Signs and Symptoms of Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Exposure: Medical Conditions Eye and skin conditions. Aggravated by Exposure: Routes of Exposure: Dermal. HILTI®is a registered trademark of Hilti Corp. Carcinogenicity: IARC classifies crystalline silica(quartz sand)as Group I based upon evidence among workers in industries where there has been long-term and chronic exposure (via inhalation) to silica dust; e.g. mining, quarry, stone crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this classification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin, use an abrasive containing hand cleaner. If material does not come off,buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician. If a large quantity was ingested, give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General(natural or mechanically induced fresh air movements). Eye Protection: Not required,however,safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact.Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSH- approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air-supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Store in a cool, dry area preferably between 40°and 77°F. Keep from freezing. Do not store in Precautions: direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene; i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow label/use instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local,state,or federal requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated. IATA/ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III,Section 313: This product contains < 3% ethylene glycol (CAS 107-21-1) and < 15% zinc borate (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local,state,and federal safety,health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health I Safety: 1 800 879 6000 Jerry Metcalf (x6704) Emergency#(Chem-Trec): 1 800 424 9300(USA,PR,Virgin Islands, Canada); 001 703 527 3887(other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. MSS 259, Page 2 of 2 4.46 MOLD AND MILDEW RESISTANT SOLUTIONS Hilti Firestop HILT! FIRESTOP AND CONSTRUCTION Testing for Mold Resistance CHEMICAL PRODUCTS WITH ASTM-G21 The test method used to determine ZERO GROWTH RATING. the effect of fungi on materials is ASTM G-21 "Determining Resistance of CFS-S SIL GG CF 812 Synthetic Polymeric Materials to Fungi". CFS-S SIL SL CFS-BL Test is conducted by placing a sample of material on a surface of agar and CP 506 CFS-CC sprayed with fungi spore.The sample is CP 572 CFS DID then covered and incubated at 82 to 86°F(28 to 30°C)and not less then CP 606 CFS-PL a 85% relative humidity for minimum 28 days.The only potential nutrient is CP 617 CFS-SL GP the sample itself. If the sample is not CP 618 CFS-SL SK attacked by fungi then the material is considered mold and mildew resistant. CP 620 CFS-SK RK The material is then given a rating of CP 637 CFS-SP WB 0, 1,2, 3 or 4 with 0 being the best. CP 643N CFS-T In order to better serve our customers, CP 644 FS ONE MAX Hilti subjects all of its firestop and construction chemical products to the CP 648-E CFS-TTS ASTM G-21 test.The above listed Hilti products have received an ASTM G-21 CP 648-S CS-TTS SA rating of 0. Hilti firestop and chemical CP 653 CFS-D 1" construction products not listed here have been tested for ASTM G21,many CP 675T CS-SL SA of them receiving an ASTM G-21 CP 680-P CP 605 rating of 1.A rating of 1 represents a significantly small amount of growth CP 680-M (less than 10%)and would still be considered mold and mildew resistant. Please ask your local Hilti representative for more information. q a Hilti,Inc.(U.S.)1-800-879-8000 en esparto)1-800-879-5000 Hilti(Canada)Corporation 1-800-363-4458 www.hilti.com www.hilti.ca FIII�TI Date: June 22, 2015 Subject: Buy American Certification Product: Firestop sealant FS-ONE MAX 10.1OZ Cartridge (Item #2101531) Firestop sealant FS-ONE MAX 20.0OZ Foil (Item #2101532) Firestop sealant FS-ONE MAX 5GAL Pail (Item #2101533) To Whom it May Concern: Hilti, Inc. certifies that the above referenced product(s) as described on the Purchase Order identified above, is (are) a domestic end product (as defined in FAR Subpart 25.1, "Buy American Act--Supplies"), or satisfies the preference for domestic construction material (as defined in FAR Subpart 25.2, "Buy American Act--Construction Materials"). Sincerely, Thomas M. Horan, QA Manager Buyamencanfson emax.00c Hilti, Inc. 5400 South 122nd East Avenue Tulsa.OK 74121 USA T(918)872.9000 I F 800-879-7000 www.hiti.com 6 141`TI August 26,2015 To Whom It May Concern: Re: Hilti FS-ONE Max Firestop—LEED Info. Item Numbers: 2101531 2101532 2101533 The Hilti FS-ONE MAX Firestop is manufactured in the United States There is no post-consumer or post-industrial content in FS-ONE MAX and it cannot be recycled. The VOC content for FS-ONE MAX is 9 grams/liter. FS-ONE MAX is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non- regulated industrial waste can vary from state to state and even city to city. For this reason,you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at(918)872-3704 if you have questions. Sincerely, )9- A2 /9 Jerry Metcalf MPH,CHMM Sr. Manager,Safety/Environmental Hilti Inc (918)872 3704 jerry.metcalf(c hilti.com Rev. Date: 7/31/15 The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America requirements,as those requirements differ. The manufacturing plant location(s)identified on the certificate represent standard Hilti catalog products only. "Specially'produced non-catalog Hilti products may have differing manufacturing plant locations. Contact your Hilti representative in cases of"specially"produced products for a custom LEEDS certificates. Hilts, Inc. 5400 South 122n°East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com 7 Certificate of Com i liance Certificate Number 20100512-R13240 Page 1 of 1 Report Reference 2010 May 12 Underwriters Date 2010 May 12 Underwriters uL Laboratories Inc.e Issued to: Hilti, Inc. 54 S 122ND East AVe Tulsa,OK 74146 USA This is to certify that Fill, Void or Cavity Materials representative samples of FS-ONE Have been investigated by Underwriters Laboratories Inc.®(UL)or any authorized licensee of UL in accordance with the Standard(s)indicated on this Certificate. Standard(s)for Safety: ANSUUL 1479,ANSI/UL 2079,CAN/ULC-S115-05 Third Edition,revised March 1,2010 Additional Information: FS-ONE Sealant for use in Joint Systems and FS-ONE for use in Through-Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow-Up Service. The UL Classification Mark includes:UL in a circle symbol:a with the word"CLASSIFIED"(as shown);a control number (may be alphanumeric) assigned by UL;a statement to indicate the extent of UL s evaluation of the product; and,the product category name(product identity)as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product Issued by: Reviewed : 'Mona Couloute Chris...I son Underwriters Lahotatom,Inc. Underwriters Laboratories Inc. Any information and dorumentation involving UL Mark services are provided on behalf of Underwriters laboratories Inc.(t 6)or any authorized licensee of UL. M11`.T1 Hilti.Outperform.Outlast. FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register/Vol.77.No.58/Monday,March 26,2012/Rules and Regulations Dale of issue:07/04/2017 Revision date:07/04/2017 Supersedes:12/17/2015 Version:1.3 SECTION 1: Identification 1.1.Identification Product form Mixture Name FS-ONE MAX; CFS-FIL Product code BU Fire Protection Chemical structure ;gi _ 1.2.Relevant identified uses of the substance or mixture and uses advised against No additional information available 1.3.Details of the supplier of the safety data sheet Hilti,Inc. Legacy Tower,Suite 1000 75024 Plano-USA T+1 9724035800 1-800-879-8000 toll free-F+1 918 254 0522 Supplier Department issuing data specification sheet Hilti,Inc. Hilti AG Legacy Tower,Suite 1000 Feldkircherstralle 100 75024 Plano-USA 9494 Schaan-Liechtenstein T+1 9724035800 T+423 234 2111 1-800-879-8000 toll free-F+1 918 254 0522 chemicals.hset hilti.com 1.4.Emergency telephone number Emergency number Chem-Trec Tel.:1 800 424 9300(USA,PR,Virgin Islands,Canada) Tel.:703 527 3887(Other countries) +1 918 8723000 1-800-879-8000 toll free SECTION 2: Hazards identification 2.1.Classification of the substance or mixture GHS-US classification Not classified 2.2.Label elements GHS-US labelling No labelling applicable 2.3.Other hazards No additional information available 2.4.Unknown acute toxicity(GHS US) Not applicable 05/07/2017 US-OSHA-en 1/7 N,�T1 Hilti.Outperform.Outlast. FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register/Vol.77,No.58/Monday,March 26,2012/Rules and Regulations SECTION 3: Composition/information on in•redients 3.1. Substance Not applicable 3.2. Mixture Name Product Identifier y GHS-US classification Quartz (CAS No)14808-60-7 2.5-5 Care.1A,H350 Full text of H-statements:see section 16 SECTION 4: First aid measures 4.1.Description of first aid measures First-aid measures after inhalation Get medical advice/attention if you feel unwell. First-aid measures after skin contact Wash skin with plenty of water.If skin irritation occurs:Get medical advice/attention. First-aid measures after eye contact Rinse cautiously with water for several minutes.Remove contact lenses,if present and easy to do.Continue rinsing.If eye irritation persists:Get medical advice/attention. First-aid measures after ingestion Get medical advice/attention if you feel unwell. 4.2.Most important symptoms and effects, both acute and delayed No additional information available 4.3.Indication of any immediate medical attention and special treatment needed No additional information available SECTION 5: Firefightin• measures 5.1.Extinguishing media Suitable extinguishing media Water spray.Dry powder.Foam.Carbon dioxide. 5.2.Special hazards arising from the substance or mixture Reactivity The product is non-reactive under normal conditions of use,storage and transport. 5.3.Advice for firefighters Protection during firefighting Self-contained breathing apparatus.Complete protective clothing. SECTION 6: Accidental release measures 6.1.Personal precautions,protective equipment and emergency procedures 6.1.1.For non-emergency personnel No additional information available 6.1.2.For emergency responders Protective equipment For further information refer to section 6:"Exposure controls/personal protection". 6.2.Environmental precautions Na additional information available 6.3.Methods and material for containment and cleaning up Methods for cleaning up Mechanically recover the product. 6.4.Reference to other sections For further information refer to section 13. 05/07/2017 US-OSHA-en 2/7 MITI Hilti.Outperform.Outlast. FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register/Vol.77,No.58/Monday,March 26,2012/Rules and Regulations SECTION 7: Handlin• and stora•e 7.1.Precautions for safe handling Precautions for safe handling Wear personal protective equipment. Hygiene measures Wash contaminated clothing before reuse.Do not eat,drink or smoke when using this product. Always wash hands after handling the product. 7.2.Conditions for safe storage,Including any incompatibilities Storage conditions Keep cool.Store in a dry place. Storage temperature 41-77°F SECTION 8: Exposure controls/personal protection 8.1.Control parameters Quartz(14808-60-7) OSHA Remark(OSHA) (3)See Table Z-3. Additional information The product has a pasty consistency.Exposure limit values for respirable dusts are not relevant for this product 8.2.Exposure controls Personal protective equipment Protective clothing.Safety glasses.Gloves. 0 gra all Hand protection Protective gloves.EN 374. Eye protection Chemical goggles or safety glasses. Skin and body protection Wear suitable protective clothing. SECTION 9: Ph sical and chemical properties 9.1.Information on basic physical and chemical properties Physical state Liquid Appearance Pasty. Colour red Odour characteristic Odour threshold Not determined pH 2=7.85 Melting point Not applicable Freezing point No data available Boiling point No data available Flash point Not applicable Relative evaporation rate(butylacetate=1) No data available Flammability(solid,gas) No data available Explosive limits No data available Explosive properties No data available Oxidising properties No data available Vapour pressure No data available Relative density No data available Relative vapour density at 20°C No data available 05/07/2017 US-OSHA-en 3/7 III�11�T1 Hilti.Outperform.Outlast. FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register/Vol.77,No.58/Monday,March 26,2012/Rules and Regulations Density =1.35 g/cm' Molecular mass Not determined Solubility No data available Log Pow No data available Auto-ignition temperature No data available Decomposition temperature No data available Viscosity No data available Viscosity,kinematic No data available Viscosity,dynamic No data available 9.2.Other information VOC content 9 WI SECTION 10: Stability and reactivity 10.1.Reactivity The product is non-reactive under normal conditions of use,storage and transport. 10.2.Chemical stability Stable under normal conditions. 10.3.Possibility of hazardous reactions No dangerous reactions known under normal conditions of use. 10.4.Conditions to avoid None under recommended storage and handling conditions(see section 7). 10.5.Incompatible materials No additional information available 10.6.Hazardous decomposition products Under normal conditions of storage and use,hazardous decomposition products should not be produced. SECTION 11: Toxicological information 11.1.Information on toxicological effects Acute toxicity Not classified Skin corrosion/irritation Not classified pH:m 7.85 Serious eye damage/iritation Not classified pH:m 7.85 Respiratory or skin sensitisation Not classified Germ cell mutagenicity Not classified Carcinogenicity Not classified Quartz(14808-60-7) IARC group 1-Carcinogenic to humans Reproductive toxicity Not classified Specific target organ toxicity(single exposure) Not classified Specific target organ toxicity(repeated Not classified exposure) 05/07/2017 US-OSHA-en 4/7 111IM1 Hilti.Outperform.Outlast. FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register/Vol.77,No.581 Monday,March 26,2012/Rules and Regulations Aspiration hazard Not classified SECTION 12: Ecological information 12.1.Toxicity Ecology-general The product is not considered harmful to aquatic organisms nor to cause long-term adverse effects in the environment. 12.2.Persistence and degradability No additional information available 12.3.Bioaccumulative potential No additional information available 12.4.Mobility in soil No additional information available 12.5.Other adverse effects Effect on the global warming No known effects from this product. SECTION 13: Disposal considerations 13.1.Waste treatment methods Waste treatment methods Dispose of contents/container in accordance with licensed collector's sorting instructions. Waste disposal recommendations Dispose in a safe manner in accordance with local/national regulations. SECTION 14: Transport information In accordance with ADR/RID/IMDG/IATA/ADN ADR IMDG IATA RID 14.1.UN number Not regulated for transport 14.2.UN proper shipping name Not applicable Not applicable Not applicable Not applicable 14.3.Transport hazard classes) Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable 14.4.Packing group Not applicable Not applicable Not applicable Not applicable 14.5.Environmental hazards Dangerous for the environment: Dangerous for the environment: Dangerous for the environment: Dangerous for the environment: No No No No Marine pollutant:No No supplementary information available 05/07/2017 US-OSHA-en 5/7 N�`'T� Hilti.Outperform.Outlast. FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register/Vol.77,No.58/Monday,March 26,2012!Rules and Regulations 14.6.Special precautions for user -Overland transport -Transport by sea No data available -Air transport No data available -Rail transport Carriage prohibited(RID) No 14.7.Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code SECTION 15: Regulatory information 15.1.US Federal regulations All components of this product are listed,or excluded from listing,on the United States Environmental Protection Agency Toxic Substances Control Act(TSCA)inventory 15.2.International regulations CANADA FS-ONE MAX;CFS-FIL WHMIS Classification Uncontrolled product according to WHMIS classification criteria EU-Regulations No additional information available Classification according to Regulation(EC)No.1272/2008[CLP] Not classified National regulations Quartz(14808-60-7) Listed on IARC(International Agency for Research on Cancer) 15.3. US State regulations California Proposition 65-This product does not contain any substances known to the state of California to cause cancer,developmental and/or reproductive harm SECTION 16: Other information Revision date 07/04/2017 Full text of H-statements: H350 I May cause cancer 05/07/2017 US-OSHA-en 6/7 Hilti.Outperform.Outlast. FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register/Vol.77,No.56/Monday,March 26,2012/Rules and Regulations NFPA health hazard 0-Materials that,under emergency conditions,would offer no hazard beyond that of ordinary combustible materials. NFPA fire hazard 0-Materials that will not burn under typical dire conditions, including intrinsically noncombustible materials such as concrete,stone,and sand. NFPA reactivity 0-Material that in themselves are normally stable,even under fire conditions. Hazard Rating Health 0 Minimal Hazard-No significant risk to health Flammability 0 Minimal Hazard-Materials that will not burn Physical 0 Minimal Hazard-Materials that are normally stable,even under fire conditions,and will NOT react with water,polymerize,decompose,condense,or self-react.Non-Explosives. Personal protection B B-Safety glasses,Gloves SOS U5 Hilti This information is based on our current knowledge and is intended to describe the product for the purposes of health,safety and environmental requirements only.It should not therefore be construed as guaranteeing any specific property of the product 05/07/2017 US-OSHA-en 717 CERTIFICATE OF COMPLIANCIE Certificate Number 20150108-R13240 Report Reference R13240 Issue Date 2015-January-08 Issued to: Hilti Construction Chemicals, Div of Hilti Inc. 5400 S 122nd East Ave Tulsa, OK 74146 This is to certify that Fill, Void or Cavity Materials representative samples of Fill, Void or Cavity Materials Certified for Canada FS-ONE MAX Intumescent Sealant for use in Through- Penetration Firestop and Joint Systems in the UL Fire Resistance Directory and in the Products Certified for Canada Directory. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s)for Safety: ANSI/UL 1479, "Fire Tests of Through-Penetration Firestops," — Edition 4 ANSI/UL 2079, "Tests for Fire Resistance of Building Joint Systems," — Edition 4 — Revision Date 2014/12/17 CAN/ULC-S115, "Standard Method of Fire Tests of Firestop Systems."— Edition 4 — Issue Date 2011/06/01 Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow-Up Service. The UL Classification Mark includes: UL in a circle:with the word "CLASSIFIED" >0 (as shown); a control number(may be alphanumeric)assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and the product category name (product identity)as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product. William R.Carney,Director,North American Certification Programs UL LLC (1011 My Information and documentation involving UL Mark services are provided on behalf of UL LLC(UL)or any authorized licensee of UL.For questions,please contact a local UL Customer Service Representative al www.ul.coMcon$ctu, Page 1 of 1 Lubrizol FE1 g.,,a SYSTEM COMPATIBLE July 13,2016 Chad D. Stroike, UPS PS Fire Protection Engineering Manager Hilti North America 5400 S. 122nd E Ave. Tulsa,OK 74I46 Dear Chad, Lubrizol Advanced Materials is pleased to announce that the following Hilti products have met the standards and are deemed to be FBCTM System Compatible. Hilti®FS-ONE Firestop Sealant Hilti®FS-ONE MAX Firestop Sealant Hilti®CP 648-S and CP 648-E Firestop Wraps Hilti®CP 680-N and CP 680-P Firestop Cast-in Devices Hilti®Top Seal Plug Hilti®Water Barrier Module Hilti®CP 643N Firestop Collar Hiiti®CFS-S SIL GG Hilti®CFS-S SIL SL The FB( System Compatible Program is designed to test and monitor ancillary products on an ongoing basis to ensure chemical compatibility with FlowGuard Gold® and Corzan®water distribution systems and BlazeMaster®Fire Sprinkler systems. Sincerely, Julie E. Schade FBCTm System Compatible Program Manager Lubnzol Advanced Materials,Inc. 9911 Brecksville Road Cieveiand,OH 44 1 4 1-3201 ww w lubrizol.corn Spare Sprinkler Head Storage Cabinet F P P I® Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines.The Spare Sprinkler Head Cabinets are available in six configurations.Three head,six head, six head ESFR, twelve head,twenty-four head, and thirty-six head.All six styles are manufactured with "knockouts" to accommodate the most common size sprinklers.The shelf is positioned to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished in red enamel. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. Installation Specifications Select the correct Spare Sprinkler Head Cabinet in accordance with the Automatic Sprinkler Systems Handbook.As per the 1989 Edition the correct number of spare Material: Steel-22:Gauge sprinkler is as follows: Finish: 0-300 sprinklers, not less than 6;300-1000, not less than 12; 1000 or more, not Red enamel less than 24. Stock of spare sprinklers shall include all types and ratings installed.* Styles: 3 Spare sprinklers,'/z or 3/4 Once the correct Spare Sprinkler Head Cabinet has been selected, installation 6 Spare sprinklers,'/z or�/a is accomplished by inserting the correct fastener in each of the holes inside the 126 S Sp ESFR,'er 3/4 or 1" Spaa rr e sprinkle rs Yz or'/a cabinet, securing the cabinet securely to the wall. Insert the correct number and 24 Spare sprinklers type of sprinklers in accordance with the"handbook". 36 Spare sprinklers *Final determination is subject to approval by the AHJ. 3198 LIONSHEAD AVE CD, CA 92010 TEL+5117760 599-11168 +1 800 344-1822 FAX+1 800 344-3775 ©2016 Fire Protection Products,Inc. 111111. • • Spare Sprinkler Head Storage Cabinet 47I111 FPPI Dimensions Cabinet Type Length Depth Height Height (open) 12 head cabinet 14 1/4" 4" 5 1/4" 10 7/,fi (02-400-00) 6 head cabinet 141/4" 27/, ' 5 Ya" 10 IA" (02-401-00) 3 head cabinet 7 s/,6 2 1/2" 51/4" 10 A" (02-402-00) ESFR cabinet, 6 head 141/4" 3 3/It 61/2" 12 3/4" (02-403-00) 24 head cabinet 141/4" 4" 87/s 17„ (02-404-00) 36 head cabinet 12 5/1fi 4" 11 3/4" 261V ' (02-405-00) (Length open) 3198 LIONSHEAD AVE CA SBAD, CA 92010 TER+1 760 760 59g168 1 ., FAX+1 800 344-3775 ©2016 Fire Protection Products,Inc. 1111II. • • • I � Spare Sprinkler Head Storage Cabinet M, FPPI® "Height Open" "Length" "Height Closed" "Depth" Item Numbers 02-400-00 to 02-404-00 _ 3198 LIONSHFAD AVE CARL BAD, CA 92010 T L 1 760 5 168 +S TEL 760 99--1 s FAX+1 800 344-3775 ©2016 Fire Protection Products,Inc. ►! 1111 I Spare Sprinkler Head Storage Cabinet s F P P I "Depth" 1 o _ e 0 0 0 0 0 0 — "Height" I 0 0 0 0 0 0 \ i I "Length" I "Length Open" Item Number 02-405-00 3198 LIONSHEAD AVE C�RLSBA60599 92010 TEL 68 +1 800 344-1822 ® FAX+1 800 344-3775 ©2016 Fire Protection Products,Inc. 111111. • • , II Bulletin 205 October 2021 Reliable Sprinkler Wrenches Standard Wrenches Model 08611 WrahM Model JD Wrench ® D556 - D-1.D-3,D D-5 guards on K5.6 (BO)and smaller sprinklers MedN F'SR Wrench __... Model JVWrench • F,l • F3GR �� • �'0-1,DB,D-9lMerds on sprCYders 3R85 • DH Dry ___--- _— Model HYWench Model WZ Wrench • GLt12 F7Res KFR • GXLO DD •• F1S • FR • GVELO DHexx3pl Ory • G LT56, • GFR VELD • MBEC • f1 • GFR • KRes ... _. • F1FR - GP • WP56 • N?S6L --I ModNJI Wrench • J • Ft WSWrench JL 1 • HL-22 • N25 N252EC ModNJ Wench 1 �� • D-403 -5 guards on KBU 1l 151 sprinklersnklers F series guards on sprinklers Recessed/Concealed Wrenches '.. Model FC Wrench --- Model RJ Wrench Model XLO2 Wreath • G5-56 Dry J - • • GCwihocap l • JL F3 • RFC wihout Cap • F3Oe E USoc erewut cop • Chi �.: WP56C O ., Dry • .li0 GFR VELO Model G6 Wrench '. Model Wt Wrench Model ZX Wrench ir. • F4FR • KFR • XL Pemtell • G4 • KRes • G4XL0 Model G6 Wrench Model W3 Wrench Model ZX-HSW Wrench GG .. • G5 with snerx.'nabe cap • XL RSV./ w • LT`x�wd�wrnrar�%'AeIII reel �4 —t Model N Wlentlh Model YP/Wench N252EC • F1Res • F1,FILL,FI SS - F1FR,FIFRLL,FIFRSS • FIS • LT5,,1756E - GFR Model RC Wrench Model WI Wrench • G Recessed - • Plastic Grratebuse wrench spare t cap cabkhet -RFC withoutououl cap I 3 1 I wwm.reliadesp rkler cum L .. SPRINKLER IDENTIFICATION SIGNS r ALUMINUM [ co *Designed to mark Fire Sprinkler Components •.0285" (21 gauge) White Aluminum Printed with Bright Red Fade Resistant Ink *Holes in each Corner for easy installation •Designed in accordance to NFPA requirements 6"x 2" AIR CONTROL COSTANDPIPEMBINATION FIRE DEPARTMENT CONNECTION IN THIS BUILDING OPEN SPRIIKLER CONTROL TEST&DRAIN ` 50-10-010 50.10-088 50-10-189 50-10-250 50-10-300 50-10-355 AIR LINE CONTROL VALVE FIRE SPRINKLER IN THIS SECTION OPEN SPRINKLER DRAIN TEST VALVE ALARM 50-10-020 50-10-100 50-10-220 50-10.260 50-10-310 50-10-380 ALARM LINE DO NOT CLOSE FIRE SPRINKLER LOW POINT DRAIN OPEN VALVE WATER MOTOR LINE PIPE 50-10-030 50-10-129 50-10-221 50-10-275 50-10-312 50-10-390 ALARM TEST DRAIN CONTROL VALVE MAIN CONTROL SPRINKLER WET STANDPIPE 50-10-040 50-10-130 " 50-10-224 50-10-280 50-10-317 50-10-400 ANTIFREEZE SYSTEM DRAIN VALVE FIRE SPRINKLER MAIN DRAIN SPRINKLER WET STANDPIPE VALVE VALVE ROOM SHUTOFF 50-10-045 50-10-140 50-10-225 50-10-290 ' 50-10340 - -420 SPAIAUUTOR ATIC DRY STANDPIPE FIRIESPR 3 DER NORMALLY CLOSED STANDPIPE SYSTEM 50-10-050 50-10-150 50-10-228 50-10-293 50-10-350 50-10-425 AUXILIARY DRAIN ENTIRE SYSTEM INSPECTORS TEST OPEN SPRINKLER 50-10-070 50.10-160 50-10-270 50-10-297 .020 Aluminum • Holes drilled in corners • Zinc Plated Sign Chain Available 6"x 4" 50-10-191 FIRE 50-10-411 COMBINATION DEPARTMENT WET STANDPIPE CONNECTION STANDPIPE SHUTOFF AUTOMATIC SHUT-OFF so-to-oso FIRE SPRINKLER FIRE WET DEPARTMENT DEPARTMENT CONNECTION STANDPIPE CONNECTION (STANDPIPE) CONTROL 50-10-190 System No. Location Spec Section Paragraph Submitted By Date Approved Date i ARGCO.com XARGCO Updated 6/13/2018 0ARGCO �xr„"� pe SPRINKLER IDENTIFICATION SIGNS ALUMINUM AR CO ,.wca O tale, 5" x 7" Hydraulic Calc Signs Bright Red Background with White Copy and HYDRAULIC-SYSTEM ` If>a,r,1 r*wwS.ayw. Boxes This building is protected M by a Hydraullcany Designed Automatic Sprinkler System Location Available in Three different styles: No.of Sprinklers twe'—� Basis of Design %^ •.020 Aluminum with holes drilled in corners System Demand •Available Personalized v 5010240 5040240-NFPA 9" x 7" Signs FDC Signs THIS VALVE CONTROLS SPRINKLER PRINKLERPLY TO F DC AUTOMATI SPRINKLERS FIRE-ALARM FDC NBE OPEN TIMES WHEN BELL RINGS CALL FIRE DEPT.OR 911 ae J.E,ova UM: wm.,. 50-10-120 50-10-171 THIS VALVE CONTROLS -1- STANDPIPE . SPRINKLER F DC MUST OPEN A TITMES ALL CONTROL • • ENTIRELY., VALVE 50-10-351 50.10-322 See Argco.com for full selection and sizes System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com • ARGCO Updated 6/13/2018 0ARGCO SPRINKLER IDENTIFICATION SIGNS 12" x10" Signs AR CO AUTOMATIC AUTOMATIC AUTOMATIC SPRINKLER AUTOMATIC SPRINKLER SPRINKLER SHUT•OFF SPRINKLER IN GARAGE ONLY IN LOCATED FT, SHUT-OFF BASEMENT ONLY OPPOSITE THIS SIGN 50-10-046 50-10-047 50-10-048 50-10-060 SIAMESE SPRINKLER SPRINKLER SPRINKLERS, CONNECTION CONTROL FIRE THROUGHOUT FOR FIRE DEPT. VALVE ALARM BUILDING 50-10-315 50-10323 50-10-331 50-10-333 Zinc-Plated STANDPIPE STANDPIPE Sign Chain SHUT-OFF 100 ft. box (50-99-100) 50-10-345 50-10-360t^�',""}+,; ty,`+}S Miscellaneous Signs ' /�-1O SP FIRE HOSE FIRE STANDPIPE COLD WEATHER / ye .COryyFc9 \ IN OTHER STAIRWAY . IN OTHER STAIRWELL VALVE 8"x 3" 5010214 8"x 3" 5010227 8"x 3" 5010081 1 AUTOMATIC FIRE ALARM \ �um:651DC 0late SPRINKLER cast aluminum 6510330 DRAIN VALVE SPRINKLER WHEN BELL RINGS Aluminum Bell Sign plastic:6510340 ALL FLOORS o911 5010172 12"x 6" 50-10.329 12"x 6" 5010061 FIRE SPRINKLER DEPARTMENT FIRE HOSE CONNECTION VALVE ROOM Cast Aluminum 8"x 4" 50-10-195 12"x 4" 5010217 24"x 12" 5010342 System No. Location Spec Section Paragraph Submitted By ,Date Approved Date ARGCO.com ARGCO Updated 6/13/2018 ©ARGCO SPRINKLER IDENTIFICATION SIGNS it . PERSONALIZED ALUMINUM [APiaCO The best way to advertise on the jobsite •Designed to mark Fire Sprinkler Components •.0285" (21 gauge) White Aluminum Printed with Bright Red Fade Resistant Ink •Available as generic signs or personalized with Company Name & Logo •Holes in each Corner for easy installation •Designed in accordance to NFPA requirements •Made in USA 4$p kl A wcan = nr 11 s' DIAL 911 � ; cm" NC ERP. MINN 1 3A NN EMEROENG,.eivocE��l pTUJ]1 7 rl ntle 'MI • NVORAVuc rSitY 911 y Ut r { 1 ~�• -. AU7CUARV[FILM/ . 611 Mq MAMCONTNOL V VE 111111111111 THIS VALVE CONTROLS STANDPIPE CONTROL VALVE • f , I a +, BE OPEN TALL ► , , BE ALL signikwommonn- wmmy 7:16« Personalized Decals, Inspection som Tags and Gauges also available. s,z• ALLIED FIRE SPRINKLER COMPANY 'Y COMMERCIAL. RESJDENTIAL, INSPECTIONS It 'V 800-854-1015 Allow 4-6 weeks delivery from artwork MAIN DRAIN approval date. System No. Location Spec Section Paragraph Submitted By I Date Approved Date ARGCO.com XARGCO Updated 6/13/2018 ©ARGCO Boas qe Worldwide www.tyco-fire.com tiissi Contacts BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Technical Description Data TYCO CPVC Pipe and Fittings pro- Sizes duced by Johnson Controls are 3/4 Inch to 3 Inch .t designed exclusively for use in wet pipe automatic fire sprinkler systems. Maximum Working Pressure The TYCO CPVC Pipe and Fittings are 175 psi produced from BLAZEMASTER CPVC Approvals ' • X<. compound that is a specially developed UL and C-UL Listed thermoplastic compound composed FM Approved of post chlorinated polyvinyl chloride LPCB Approved (CPVC)resin and state of the art addi- NSF Certified = - y tives.TYCO CPVC Pipe and Fittings are MEA Approved easier to install than traditional steel (Refer to Installation Handbook IH-1900 pipe systems, and at the same time, dated April 2016 for exact listing/approval provide superior heat resistance and information.) Installation strength as compared to traditional Manufacture Source CPVC and PVC piping materials used U.S.A. TYCO CPVC Pipe and Fittings are to in the plumbing trade. Various adapt- be to be installed in accordance with ers are available to connect CPVC Material Installation Handbook IH-1900. pipe to metallic piping.All female pipe Pipe: thread adapters have brass inserts for ASTM F442,SDR 13.5 durability. Grooved adapters connect Fittings: directly to grooved end valves and ASTM F438(Sch.40) metallic pipe,with flexible grooved end ASTM F439(Sch.80) couplings. ASTM F1970 NOTICE O Orange The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION(NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Page 1 of 2 AUGUST 2018 TFP1915 TFP1915 Page 2 of 2 Care and Limited Maintenance Warranty TYCO CPVC Pipe and Fittings are to be For warranty terms and conditions,visit maintained and serviced in accordance www.tyco-fire.com. with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service,notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de-vices in compliance with this document,as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION(e.g., NFPA 25), in addition to the standards of any authority having jurisdiction.Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected,tested,and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1.215-362-0700 ,111�n 02018 Johnson Controls.AB rights reserved.All specifications and other Information shown were current es of document revision date and are subject to change without notice. Johnson ,I NATIONAL FIRE PROTECTION ASSOCIATION and MGM are fepieteredtrtlarne,ks of National Fba P,Olecllon Awvctation: Controls C BLAZEMASTER Is a trwlamert of IN,Lubnmt COPOration L ti) State Pipe & Supply, Inc. THIS INFORMATION PROVIDED IS BASED ON ASTM GUIDELINES FOR WELDED PIPE SPECIFICATIONS AND ASTM REQUIREMENTS. ACTUAL PIPE AND MATERIAL TEST REPORTS PROVIDED WOULD MEET OR EXCEED THESE GUIDELINES. TEST REPORTS WOULD PROVIDE SPECIFIC AND ACTUAL DETAILS CONCERNING THE MECHANICAL AND CHEMICAL PROPERTIES OF THE ACTUAL PIPE,AS WELL AS ADDITIONAL TESTS RESULTS REQUIRED BY ASTM. SCHEDULE 10**Black and Galvanized Steel ERW Pipe Pipe Size Test Pressure Nominal O.D I.D. Weight/Foot psi 1" 1.315 1.097 1.410 700 1-1/4" 1 660 1 442 1.810 1200 1-1/2" 1.900 1.682 2.090 1200 2" 2.375 2.157 2.640 2300 2-1/2" 2.875 2.635 3.530 2500 3" 3.500 3.260 4.340 1290 4" 4.500 4.260 5.620 1000 5" 5.563 5.295 7.780 1010 6" 6.625 6.357 9.300 1020 8.625 8 249 16.960 780 8"wall thickness is 0.188,not SCH10 or 0.148"wall thickness. COMPOSITION AND PROPERTIES Chemical and mechanical properties requirements are as prescribed by applicable ASTM standards edition January 2006. Chemical Requirements.Percent(Product) C Mn P S Other Specification Grade max max Max max ASTM A53 A 0.250 0.950 0.05 0.045 - 1 Residual elements max.Cu-040.Ni-0.40.Cr-0.40.Moo 15 and V-.08. These bye elenve Iv combined shalt not exceed 1%. Mechanical Properties-Tensile Requirements Stren -psi. Yield Tensile Specification Grade Min Max Min Max ASTM A53 A 30,000 - 48,000 - NOTE. Elongation requirements vary with nominal area of test specimen and specified minimum tensile strength of the steel grade 9615 S.Norwalk Blvd..Santa Fe Springs,CA 90670 •(562)695-5555 •FAX!(562)692-1054 •www.statepipe.com IIIli) State Pipe & Supply, Inc. THIS INFORMATION PROVIDED IS BASED ON ASTM GUIDELINES FOR WELDED PIPE SPECIFICATIONS AND ASTM REQUIREMENTS. ACTUAL PIPE AND MATERIAL TEST REPORTS PROVIDED WOULD MEET OR EXCEED THESE GUIDELINES. TEST REPORTS WOULD PROVIDE SPECIFIC AND ACTUAL DETAILS CONCERNING THE MECHANICAL AND CHEMICAL PROPERTIES OF THE ACTUAL PIPE.AS WELL AS ADDITIONAL TESTS RESULTS REQUIRED BY ASTM. SCHEDULE 40 Black and Galvanized Steel ERW Pipe Pipe Size Test Pressure Nominal D.D. I.D. Weight/Foot psi 1" 1.315 1.049 1.680 700 1-1/4" 1.660 1.380 2 270 1200 1-12" 1.900 1 610 2.720 1200 2" 2.375 2.067 3.660 2300 2-1/2" 2.875 2.469 5.800 2500 3" 3.500 3.068 7.580 2220 4" 4.500 4.026 10 800 1900 5" 5.563 5.047 14.630 1670 6" 6.625 6.065 18.990 1520 8•' 8.625 7.981 28.580 1340 COMPOSITION AND PROPERTIES Chemical and mechanical properties requirements are as prescribed by applicable ASTM standards edition January 2006. Chemical Requirements,Percent(Product) C Mn P S Other Specification Grade max max max max ASTM A53 A 0.250 0.950 0 05 0.045 - 1 Residual elements max Cu-0 40.Ni-0.40 Cr-0 40,M o-0.15 and V..08. These five elements combined stun not exceed t% Mechanical Properties-Tensile Requirements Stren th-psi. Yield Tensile Specification Grade Min Max Min Max ASTM A53 A 30,000 - 48,000 - NOTE. Elongation requirements vary with nominal area of lest specimen and specified minimum tensile strength or the steel grade. 9615 S.Norwalk Blvd.,Santa Fe Springs.CA 90670 •(562)695-5555 •FAX!(562)692-1054 •www.statepipe.com ES-A-I n Bu i ld i n g Ri ser Engineering Specification Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative ■ Series IBR In-Building Risers Customizable Sizes: 4" - 10" ?EST c111 Series IBR In-Building Risers are used to connect the main fire t Now INCLIW supply to the building overhead fire system.The fitting passes under the foundation without joints and extends up through the floor. Provided with installation tabs,the unit has a CIPS(Cast Iron Pipe Size)coupler for easy connection to the underground supply(AWWA C900 PVC and Ductile Iron Pipe)and industry standard grooved-end connection(AWWA C606)on the building 6'x6'standard length side for easy connection to the overhead fire sprinkler system. (custom lengths from 3'—20'available) The IBR features Lead Free*construction to comply with Lead Free*installation requirements. Ames In-Building Risers are precision engineered and manu- factured r� to provide exceptional reliability and reduce installation .; time&labor costs associated with field assembly. In accordance with NFPA 24,the UUFM approved In-Building Risers replace numerous fittings, elbows&spools and reduces the possibility of leaks or failure in comparison to traditional installation methods and materials. Factory tested integrity ensures the highest quality installation.The use of stainless steel significantly increases the .11 reliability and life of the riser. Building Floor _ • Building perimeter wall 0 4-- Features -, •Cost savings •Corrosion resistant stainless steel construction, type 304 •Ease of installation and light weight allows one person to posi- tion and handle the riser •Minimal site preparation;joint restraint one-piece construc- tion reduces time and labor; no missing parts, no leaks; easily 4 Qo identifiable for approvals as t., M Flow •Includes Test Cap and Coupler •UUFM approved •Sizes: available in 4"— 10"with various lengths to meet local requirements •Designed to meet NFPA 24 *The wetted surface of this product contacted by consumable water •AWWA C900 Inlet/DIPcontains less than 0.25%of lead by weight. •AWWA C606 Outlet A M E S Ames Fire&Waterworks product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measure- •-- •-• •--• ments,please contact Ames Fire&Waterworks Technical Service.Ames Fire&Waterworks reserves the right to change or modify product design,construction, FIRE&WATERWORKS specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire&Waterworks products previously or subsequently sold. A WATTS Brand Specifications Standards In-Building Riser shall be installed as indicated on the plans. NFPA — Designed to allow the contractor to conform to Riser shall be composed of a single extended 90 degree fitting NFPA 24 of fabricated ASTM A312 304 stainless steel tubing, maxi- Where a riser is close to building foundations, underground mum working pressure 200psi(14 bar).The fitting shall have fittings of proper design and type shall be used to avoid pipe joints a grooved-end connection on the outlet(building)side and a being located under the foundations. CIPS coupler on the inlet(underground)side.The grooved end shall include a coupler and cap to facilitate testing of the un- derground piping.The In-Building Riser shall be an Ames Fire& Waterworks Series IBR. Horizontal End:Mates with Ductile Iron Pipe and AWWA C900 Pipe(PVC Pipe with Ductile Iron Pipe Equivalent OD's) Approvals ® ® Utilizes Gasket conforming to UL 157 with "Lock in" Fittings FM class 1920 J gasket configuration UL HKQA(4"-10") r SIZE MATING PIPE OD in. 171M Dimensions- Weights 4 4.8 122 --pr.Hf—A 6 6.9 175 8 9.1 230 V crooned End 10 11.1 282 -- (Flange Optional) e0 Vertical End: Meets AWWA C-606 dimensions for roll grooved pipe CIPS Coupling Meets AWWA C-207 class D for flanges Tie-Rod Bracket 1 Ratings - ===�.:wni Meets AWWA C-900 pressure class 200, DR 14 Pipe I c • Testing Welds are 100%leak tested at the factory SIZE WEIGHT A(OD) B C in. in. mm ft cm ft. cm lbs. kg 4 4% 114 6 183 6 183 71 32 4 41h 114 8'-6" 183 6 183 85 39 i 4 4'% 114 9 274 6 183 88 40 4 41% 114 5 152 7 213 71 32 6 6% 168 6 163 6 183 98 44 6 6% 168 8'-6" 259 6 183 122 56 6 6% 168 9 274 6 183 127 58 6 6% 168 5 152 7 213 98 44 8 855h 219 6 183 6 183 129 59 8 8% 219 8'-6" 259 6 183 163 74 8 8% 219 9 274 6 183 170 77 NOTICE 8 8% 219 5 152 7 213 129 59 Inquire with governing authorities for local installation 10 103/4 273 6 183 6 183 202 92 requirements 10 103/+ 273 9 274 6 183 258 117 10 103/4 273 5 152 7 213 202 92 "Each B(vertical)and C(horizontal)leg is customizable from 3'to 20'with UL/FM NOTICE approvals.Consult with your factory representative for details. The information contained herein is not intended to replace the full product installation and safety information available or the experi- ence of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. AM E S FIRE&WATERWORKS A WATTS Brand USA:Backflow Tel:(978)689-6066•Fax:(978)975-8350•AmesFireWater.com USA:Control Valves Tel:(713)943-0688•Fax:(713)944-9445•AmesFireWater.com Canada: Tel:(905)332-4090•Fax:(905)481-2316•AmesFireWater.ca Latin America: Tel:(52)55-4122-0138•AmesFireWater.com ES-A-InBuildingRiser 2117 C 2021 Watts Inlet fittings are available with 1"NPT,ISO 7-1R1,3/4"N PT,or See the Available Configurations, Listings, and Approvals IS07-1 R3/4 threads.Sprinklers with 3/4"NPT and IS07-1 R3/4 table in this Bulletin for further information on Model F3QR56 inlet fittings are intended primarily for replacement of existing Dry sprinklers. 3/4"or IS07-1 R3/4 inlet dry sprinklers,but may also be used in new installations. Available Configurations, Listings, and Approvals Available Sprinkler Sprinkler Escutcheon or Listings and Inlet Identification Model Cover Plate Length Approvals(1) Threads Number (See Figs. 1-9) (SIN) Standard 2"to 36" Escutcheon (50 to 900 mm) HB Extended Escutcheon Fl Recessed cULus, NYC 3/4" NPT or Escutcheon 3-1/2" to 36" IS07-1 R3/4 FP Recessed (90 to 900 mm) Escutcheon F3QR56 Dry CCP Cover Plate R5714 Pendent Standard 2"to 48" Escutcheon (50 to 1200 mm) HB Extended Escutcheon 1" NPT F1 Recessed cULus, FM, NYC or Escutcheon 3-1/2"to 48" IS07-1 R1 FP Recessed (90 to 1200 mm) Escutcheon CCP Cover Plate Standard 2" to 48" Escutcheon (50 to 1200 mm) HB Extended Escutcheon cULus(2), NYCI2> 3/4" NPT or F1 Recessed 3-1/2" to 48" IS07-1 R3/4 Escutcheon (90 to 1200 mm) FP Recessed F3QR56 Dry Escutcheon Horizontal Sidewall Standard 2"to 48" R5734 Escutcheon (50 to 1200 mm) cULust2>, FM(3), NYC(2) HB Extended 3-1/2"to 48" Escutcheon (90 to 1200 mm) 1" NPT or F1 Recessed IS07-1 R1 Escutcheon 3-1/2"to 48" cULusI2>, FP Recessed (90 to 1200 mm) FMI3>t4>, NYCI2> Escutcheon F3QR56 Dry N/A 5"to 48" cULus(2) 1" NPT or R5724 Upright (127 to 1200 mm) IS07-1 R1 (1)For available temperature ratings and finishes see the Temperature Ratings and Finishes tables,respectively,in this Bulletin. 42)cULus Listing and NYC for Light Hazard and Ordinary Hazard only. j3)FM Approved for Light Hazard only. wi Model F3QR56 Dry Horizontal Sidewall with Model Fl or Model FP recessed escutcheon are FM Approved as Standard Response. 2. Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. 1. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) 2. Certified by FM Approvals (FM) 3. Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Nominal K-Factor: 5.6 gpm/psi12 (80 Limn/bar-1/2) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F3QR56 Dry cULus, NYC See note below 250 psi(17.2 bar) Pendent FM See note below 175 psi(12 bar) 4"to 6" 250 psi(17.2 bar) F3QR56 Dry cULus, NYC Horizontal Sidewall 4"to 12" 175 psi(12 bar) FM See note below 175 psi(12 bar) F3QR56 Dry Upright cULus See note below 175 psi(12 bar) Note: Deflector distance to be in accordance with applicable NFPA, FM, or other agency requirements. Information is provided only when additional clarification is necessary. Temperature Glass Bulb Color Sprinkler Cover Plate Maximum Ceiling Listings and Classification Temperature Rating Temperature Rating Temperature Approvals"' Orange 135°F(57°C) Ordinary 135°F(57°C) 100°F(38°C) cULus,FM,NYC Red 155°F(68°C) Intermediate Yellow 175°F(79°C) 165°F(74°C) 150°F(66°C) cULus,NYC Intermediate Green 200°F(93°C) 165°F(74°C) 150°F(66°C) cULus,FM, NYC None 225°F(107°C) cULus,FM(2),NYC High Blue 286°F(141°C) 165°F(74°C) 150°F(66°C) cULus,NYC (')For listed and approved sprinkler,escutcheon,and inlet configurations see the Available Configurations,Listings,and Approvals table in this Bulletin. (2)High temperature classification is FM Approved with Standard and Model HB escutcheons only. Finish Notes 1. Finishes vary with type of trim selected. See table provided with each sprinkler detail for finish combinations. 2. Paint or any other coating applied over the factory finish will void all approvals and warranties. 3. Other finishes and colors may be available on special order. Consult your Reliable sales representative for details. 4. For Standard, Model HB, and Model Fl trims, both components of escutcheon are finished. 5. For Model FP and CCP trims,only the trim ring and cover plate are finished.The threaded sprinkler cup is unfinished. 3. Model F3QR56 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5714) "A"Dim. 2"to 48"(51 mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 2"to 36"(51mm to 914mm)in 1/4"(6mm)increments for 3/4"connections r� 7-77 IIIII I i n�u _41 iuu__i nnu _ v I �� L ' System Fitting - - Inlet Fitting 2-1/8" "A"Dimension [54mm]Dia. Hole in Ceiling Sprinkler Can j 1"[25mm] Escutcheon — Escutcheon Adjustment -- AlCeiling 1/2"[12mm] Nominal Escutcheon Position o 1/2"[12mm] 1-5/8"Escutcheon Adjustment 1111 [41mm] 1/2"[12mm] 1„ 1 Nominal Protrusion 3"[76mm] COMDRYDET1-A DIA. Sprinkler Guard: Model C2 Fig. 1 Note:The sprinkler can protrudes 1/2"(12mm)when escutcheon is in nominal position. Escutcheon adjustment provides-1/2" (12mm)to+1"(25mm) "A"dimension adjustment range. Finish Combinations:Standard Escutcheon Notes: 1. UL Listed as Corrosion Resistant. Sprinkler Escutcheon)�1l't 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is 316 stainless steel unless noted. Bronze Polished Stainless 4. FM Approved as Corrosion Resistant. Bronze Laquered Brass Chrome Polished Stainless White Polyesterl'l White Polyester Black Polyester)') Black Polyester Custom Color Polyester<') Custom Color Polyester Electroless Nickel PTFEI4I Polished Stainless 4. Model F3QR56 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5714) "A"Dim. 31/2'to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or TA" to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections rz r-n IIIIiI I I IIIIII 1 p IIIIII i I 111111 tl II1I I I Ililn I (I ? System tee I Inlet fitting "A" Dimension 2-1/2" [64 mm] _ Dia. Hoe in Ceiling 1/2" [13mm] Escutcheon Acjustment �y I �' Cciiing 1-1/4" / [32mm] Normal Position Escutcheon of Escutcheon Sprinkler Can 1/2" [13mm] ` J Escutcheon Adjustment Deflector distance below ceiling is 3-1/2" COMDRYDET2 (89ro i) minimum, 4-1/2' (114mm) maximum 3-1/2" Sprinkler Guard: Model C2 _ [89 mm] Escutcheon Dic. Fig. 2 Note: The sprinkler can protrudes 11/4"when escutcheon is in nominal position. Escutcheon adjustment provides'/z" (-12.7mm)to+1/2" (+12.7mm)"A"dimension adjustment range. Notes: Finish Combinations: HB Escutcheon 1. UL Listed as Corrosion Resistant. Sprinkler Escutcheonsz)('> 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is 316 stainless steel unless noted. Bronze Chrome 4. FM Approved as Corrosion Resistant. Chrome Chrome White Polyester(') White Polyester Black Polyester(') Black Polyester Custom Color Polyester('') Custom Color Polyester Electroless Nickel PTFE0)(4) Stainless Steel 5. Model F3QR56 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN R5714) "A"Dim. 372"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or ,3Y:"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections -_ rZ S1 --- --- III I l __ I -- - L-, ='-j System Tee Inlet Fitting 2-5/8"[67 mm]Dia. "A"Dimension Hole in Ceiling Sprinkler 1/4"[6mm] Cup Escutcheon Adjustment _ Escutcheon t 1 Ceiling milli Ir 4 J f/ 11 r' i 3/4"[19 mm]Nom. NominalI } Escutcheon Position 1/4"[6mm] — 3-7/32" Escutcheon Adjustment I [82 mm] Dia. - COMDRYDET3 Fig. 3 Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space above. Notes: Finish Combinations: FP Recessed Escutcheon 1. Cup for FP Recessed is unfinished galvanized steel except Sprinkler's Escutcheonr'Nat electroless nickel PTFE sprinkler uses a stainless steel cup. 2. UL Listed as Corrosion Resistant. Bronze Chrome 3. Escutcheons do not carry corrosion resistant listings. 4. Base material is cold rolled steel unless noted. Bronze Brass 5. FM Approved as Corrosion Resistant. Chrome Chrome White Polyester(2) White Polyester Black Polyestert2t Black Polyester Custom Color Polyester(2) Custom Color Polyester Electroless Nickel PTFEt2t(5) Stainless Steel 6. Model F3QR56 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN R5714) "A"Dim. 3'/z"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 3/: to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections rz s L_i -J System Tee Inlet Fitting 2-1/2"[64 mm]Dia. "A"Dimension Hole in Ceiling Sprinkler Cup 3/16"[5 mm] Model CCP 1/2 Cover Plate Adjustment Cover Plate Assembly 1 A ; / Ceiling ,,, 1l k } jj 7/S" Nominal Cover [22 mm] Plate Position 3/16"[5 mm] Cover Plate Adjustment _ 3-5/16" [84 mm]Dia. COMDRYDET4 Fig.4 Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have positive pressure in the space above. Notes: Finish Combinations:CCP Conical Cover Plate 1. Cup for CCP Concealed in unfinished galvanized steel. Sprinkler Cover Plate(2) 2. Cover plates do not carry corrosion resistant listings. White Polyester Chrome Bright Bronze Chrome Dull Bright Brass Unfinished Bronze Custom Color 7. Model F3QR56 Dry Pendent Sprinkler with Model F1 Recessed Escutcheon (SIN R5714) 1--- A"Dim. 31h"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 31/2"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections. rz rr I N i ii t mumL - ---- L System Tee ■"' Inlet Fitting 2-1/4"[57 mm]Dia. Hole in Ceiling "A"Dimension Collar 1/4"[6 mm] Escutcheon Adjustment 1/8" ' + Coiling y l3 mm] Nominal Escutcheon �It, Position 11 Escutcheon 1/4"[6 mm] Escutcheon Adjustment 2-27/32" [72 mm]Dia. COMDRYDET5 Pg. 5 Notes: Finish Combinations: Fl Recessed Escutcheon 1. UL Listed as Corrosion Resistant. Sprinkler Escutcheon)�)1' 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is cold rolled steel unless noted. Bronze Chrome 4. FM Approved as Corrosion Resistant. Bronze Brass Chrome Chrome White Polyester)" White Polyester Black Polyester)" Black Polyester Custom Color Polyester<'I Custom Color Polyester Electroless Nickel PTFE111141 Stainless Steel 8. Finish Combinations: Standard Escutcheon Sprinkler Escutcheon+2)(3) Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN R5734) "A"Dim. 3'/z"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or I 3Y:"to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections Ceiling 7 wrij 4" [102mm] Min. Escutcheon 12"[305mm] Max. Sprinkler Can System Tee 2 3/32 i y Inlet Fitting 7. [53mm] I [ , I ` , 5/8"(16mm] ---4*--P- ri -- 1, — — — — — - 3 1/2" [89mm] _ ,i; „_z- Escutcheon Dia. j ., _ ____ Iy 2 1/2" Dia. 1 [64mm] -Hole in Wall 1-1/4„ \- 1-1/4 [32mm] Nominal Protrusion [32mm] 1/2"[13mm] Escutcheon Adjustment • COMDRYDET7 1/2"[13mm] Nominal Position Escutcheon - of Escutcheon Adjustment ----- "A"Dimension - - Fig. 7 Note: The sprinkler can protrudes 11/4"when escutcheon is in nominal position. Escutcheon adjustment provides-Yz"(-12.7mm)to+1/2" (+12.7mm) "A"dimension adjustment range. Notes: Finish Combinations: HB Escutcheon 1. UL Listed as Corrosion Resistant. Sprinkler Escutcheon z>('1 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is 316 stainless steel unless noted. Bronze Chrome 4. FM Approved as Corrosion Resistant. Chrome Chrome White Polyester'" White Polyester Black Polyester(') Black Polyester Custom Color Polyestero) Custom Color Polyester Electroless Nickel PTFE0"(4) Stainless Steel 10. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon (SIN R5734) "A"Dim. 31/2 to 48 (89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or I 3/z„to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections Ceiling �J Nom. 1-1/4" Escutcheon [32 mm] 4"[102 mm] Min. Sprinkler Cup cULus, NYC:6"[152 mm] Max. System Tee \\.. FM: 12"[305 mm]Max. Inlet Fitting , - . el »ir 4' a 5/8"[16 mm] rr, u \ I'\ 11 — — — — — — \\\ y 1 \\ `\y L 3-7/32" \ 1 _, --z. [82 mm]Dia. I 2-1/2" [64 mm]Dia. Hole in Wall 1/4"[6 mm] Escutcheon Adjustment COMDRYDETB 1/4"[6 mm] Nominal Escutcheon Position Escutcheon Adjustment "A"Dimension - Fig.8 Note:Do not install the Model F3QR56 Dry Horizontal Sidewall sprinkler with the Model FP escutcheon in walls which are positively pres- surized with respect to the protected space. Notes: Finish Combinations: FP Recessed Escutcheon 1. Cup for FP Recessed is unfinished galvanized steel except Sprinkler+'r Escutcheon'r'r electroless nickel PTFE sprinkler uses a stainless steel cup. 2. UL Listed as Corrosion Resistant. Bronze Chrome 3. Escutcheons do not carry corrosion resistant listings. 4. Base material is cold rolled steel unless noted. Bronze Brass 5. FM Approved as Corrosion Resistant. Chrome Chrome White Polyester{2r White Polyester Black Polyester(2) Black Polyester Custom Color Polyester Z Custom Color Polyester Electroless Nickel PTFEi2t(5) Stainless Steel 11. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model Fl Recessed Escutcheon (SIN R5734) "A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments for 1"connections or 3Y=" to 36"(89mm to 914mm)in 1/4"(6mm)increments for 3/4"connections I r:. Ceiling . .- Nom. 101 1-3/4" 1/8" [44 mm] 't Escutcheon —...- [3 mm] Collar ',,"w 4" [102 mm] Min. cULus, NYC:6"[152 mm]Max. System Tee FM: 12"[305 mm] Max. Inlet Fitting s� c`i—,F '_o Yam___. h 5/8"[16 mm] n n N.\- n - \ 1! - 2-27/32" z [72 mm] Dia. 2-1/4"[57 mm] Dia. Hole in Wall 1/4"[6 mm] Escutcheon Adjustment • ` \\ Nominal Position COMDRYDET9 1/4"[6 mm] of Escutcheon Escutcheon Adjustment "A"Dimension Fig. 9 Notes: Finish Combinations: F1 Recessed Escutcheon 1. UL Listed as Corrosion Resistant. Sprinkler Escutcheon 2 ' 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is cold rolled steel unless noted. Bronze Chrome 4. FM Approved as Corrosion Resistant. Bronze Brass Chrome Chrome White Polyester(" White Polyester Black Polyesterm Black Polyester Custom Color Polyesterm Custom Color Polyester Electroless Nickel PTFN1)(4) Stainless Steel 12. Model F3QR56 Dry Upright(SIN 5724) Order Dimensions 5"to 48"(127 mm to 1219 mm) 'TTTwT�Tc 1111 Note: Customer is responsible for determining correct deflector distance below structure above. I Order Dimension Inlet Fitting i uI 1 System Tee r -7 i I I s7 COMDRYDETIO , ,,„,i I I iini II II Ia �� II P, I �- j_ I---��I'i_-- ---+-- L-- Imo`-'----J L J -LJ Fig. 10 Notes: Finish Combinations:Upright 1. UL Listed as Corrosion Resistant. Sprinkler Escutcheon 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is cold rolled steel unless noted. Bronze NA Electroless Nickel PTFE(1) NA 13. MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM NOTE: STANDARD DRY PENDENT IS SHOWN, HOWEVER, MINIMUM EXPOSED BARREL LENGTH APPLIES TO ALL STYLES OF DRY SPRINKLERS CONNECTED TO A WET PIPE SYSTEM. WET PIPE EXPOSED BARREL AMBIENT AMBIENT TEMPERATURE Fti sl TEMPERATURE ___RI- 7-" _Si i____;--1P-__ EXPOSED TO 407/4C 507/10'C I 60Y/16'C ,` {{ L it NOTE: TEE MAY BE IN ANY DISCHARGE END EXPOSED MINIMUM BARREL LENGTH** it-- NI�-—1--J'--�-H'F"-'�ORIENTATION FOR WET PIPE OF SPRINKLER•(FACE OF FITTING TO TOP OF CEILING)... ( �JBIF 4 NMrt___. SYSTEMS IN. (MM) IN. (MM) IN. (MM) I I Y, `U 407(41C) 0 0 o r LI IF HUMIDITY AND TEMPERATURE DIFFERENTIAL 30'F(-1r) 0 0 0 INNCAUOAON ON THPSRY SPRINKLER SESC.NDENSCONSIDERTI WRAPPINGE E%THEO EXPOEDDSED 20'F(-it) 4(100) 0 0 BARREL WITH INSULATION, FOAM INSULATING 107(-12'C) 8(200) 1 (25) 0 TAPE OR EQUIVALENT. 07(-18'C) 12 (300) 3(75) 0 MINIMUM (HEATED AREA) SEAL THE CLEARANCE SPACE -IDF(-23t) 14 (350) 4(100) 1 (25) EXPOSED AROUND THE SPRINKLER TO AVOID BARREL LEAKAGE OF AIR INTO THE PROTECTED -207(-29t) 14 (350) 6 (150) 3 (75) LENGTH AREA AND CONSEQUENT FORMA P ON OF .A. CLEARANCE CONDENSATE AROUND THE FRAME. WHICH -30'F(-34'C) 16(400) 6 (200) 4(100) DIMENSION HOLE COULD INHIBIT OPERATON OR CAUSE PREMATURE OPERATION. SEE BELOW FOR -407(-40'C) 18(450) 8 (200) 4(100) ,' RECOMMENDED METHODS. -50F(-46'C) 20(500) 10 (250) 6(150) -607(-51'C) 20(500) 10(250) 6 (150) •FOR AMBIENT TEMPERATURES EXPOSED TO ME DISCHARGE --------- -"---- I—INSIDESURFACE OF _________ _________ END OF THE SPRINKLER THAT OCCUR BETWEEN THE VALUES CEILING •• THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME ------"- -'------- THE "A" DIMENSION. THE UM EXPOSED BARREL LE -`- --- LENGTH IS BASEDSEDON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WIND VELOCITY ON THE EXPOSED SPRINKLER OF 30 MPH (48 KM/H). LONGER EXPOSED BARREL LENGTHS WILL THERMAL - -ESCUTCHEON HELP AVOID FREEZING OF THE WET PIPING WHERE HIGHER BARRIER WIND VELOCITY IS EXPECTED. •• THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED DISCHARGE END OF SPRINKLER FROM THE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSULARON. WALL OR CEILING LEADING TO THE COLD SPACE. WHICHEVER IS CLOSEST TO THE FITTING. PROTECTED (NON-CONDITIONED) AREA RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS SYSTEM PIPING (DRY SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) SYSTEM PIPING ir--4ffll--*--k-H--Ih�li--L ;c- IIIlII-H---f-"-~ �I�I - ti----11__I no L-- I�t_=__,' ,ti----.H4"--'n no r=--ai t---= I LrI 1 -- r _c-- S l :- - 5 Mill (HEATED AREA) IIII'(HEATED AREA) MINIMUM MINIMUM EXPOSED BARREL 0 EXPOSED BARREL LENGTH DECK TITE FLASHING INSIDE FACE [SEAL (SEE ABOVE) RASCp b400J910 LENGTH (SEE ABOVE) (RECOMMENDED) 7 I=i ' _ ft , CI EARANCE HOLE ri INSULATED FREEZER, - OR COOLER STRUCTURE OR EXTERIOR FRAMING = I = - - y i== i i I A le. IMIIIII (PROTECTED AREA) I�tU��l DISCHARGE END RY DR AREAR OF (PROTECTED AREA) II■II0I+kirdIN- SPRINKLERY LD DISCHARGE END OF DCOM DRYDE TI I Fig. 11 14. *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING,ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction;this will damage the sprinkler,the fitting,or both. Short inlet("PL")versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations.Sprinklers with the short inlet("PL")should only be installed in CPVC fittings of wet-pipe systems. In all cases,verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal No Internal Obstruction Obstruction i. Female �/ Female 111 AO Pipe /� 0� Pipe % �� Thread �� Thread 45 CPVC Fitting with Internal Obstruction CPVC fitting - No Internal Obstruction Shorter -- Longer MT Inlet Inlet Male T Male Pipe 1111-11 Pipe — _�Thread Thread •ii PP----,-_ -.--_ Dry Sprinkler Dry Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION COMDRYDE72 Fig. 12 15. LN1;�h*.,.. S 4 Fig. 13-Model F3R Wrench 4MXdia4 P + 4 .�. { ar, ti kh YY t a a� rq�r5 Fig. 14-Model XLO2 Wrench 16. MATERIAL SPECIFICATIONS ITEM# DESCRIPTION MATERIAL SPECIFICATION • a`� �: a 1 FRAME BRASS PER UNS C83600 =\\\�///,'-�., 2 DEFLECTOR BRONZE PER UNS C51000 �rmilmit�r4 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 �D aill I 5 BULB INSERT COPPER ALLOY PEP UNS C31400 t 6 GLASS BULB GLASS WIGLYCERIN SOLUTION II It ` 7 ORIFICE ADAPTOR :: Ei STEEL� UNS C23000 I % I a, pj 10 YOKE BRASS ALLOY PER UNS C38000 ailE I ' � 71 INLET BRASS ALLOY PER UNS C36'Z�0 0 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL PTFE COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 0iii PAINTED OR PLATED MILD STEEL,EXCEPT CAN/ESCUTCHEON FOR TYPE 316 STAINLESS STEEL FOR 15 SPRINKLERS WITH ENT FINISH 0 (PIPE WRENCH MAY ONLY BE USED ON OUTER STEEL PIPE OF SPRINKLER) 1011 11 o � Ei © \\III A COMDRYDET13 1I © t!! O [ q APPEARANCE OF DEFLECTOR MAY VARY DEPENDING ON MODEL O mil. Fig. 15 17. Installation Instructions When used on wet pipe systems, Reliable Model F3QR56 3a.Alternatively, where access to the outer tube of the dry sprinklers may be installed in ductile or malleable cast iron sprinkler is available, the Model F3QR56 Dry sprin- threaded tees, or CPVC tees and adapters upon verification kler may be installed using a pipe wrench. The pipe that the sprinkler inlet fitting does not interfere with the interior wrench shall only be permitted to interface with the of the fitting(see Figure 12). galvanized steel outer tube portion of the sprinkler When used on dry pipe systems, Reliable Model F3QR56 (Item #8 in Fig. 15). Do NOT wrench any other por- dry pendent sprinklers MUST ONLY BE installed in the outlets tion of the sprinkler assembly. A pipe wrench can in- of ductile or malleable cast iron threaded tees on horizontal pipe stall the sprinkler into the fitting with a large amount such that the inlet of the sprinkler protrudes above the bottom of torque; consideration should be given to the need level of the pipe. for future removal of the sprinkler because the instal- When used on dry pipe systems, Reliable Model F3QR56 lation torque will have to be matched or exceeded to dry sidewall and dry upright sprinklers may be installed in duc- remove the sprinkler.The recommended minimum to tile or malleable cast iron threaded tees, or CPVC tees and maximum installation torque is 22 - 30 lb-ft (30—40 adapters upon verification that the sprinkler inlet fitting does not N-m) for 1" NPT and IS07-1 R1 sprinklers, and 14 - interfere with the interior of the fitting(see Figure 12). 20 lb-ft (19—27 N-m)for 3/4" NPT and IS07-1 R3/4 DO NOT install Reliable dry sprinklers into elbows or cou- sprinklers. plings,welded outlets,mechanical tees,or gasket sealed CPVC 4. Standard and Model HB escutcheons can be installed fittings. by slipping the escutcheon over the can until the es- Dry sprinklers connected to wet pipe systems must be in- cutcheon is seated against the ceiling or wall. Model Fl stalled as indicated in Figure 11 and as required by NFPA 13 escutcheons are installed by pressing the escutcheon with the Exposed Minimum Barrel Length located in a heated onto the collar until the escutcheon is seated against area. the ceiling or wall. The Model FP escutcheon is installed An orange protective clip is factory installed on the sprinkler by pressing or threading the escutcheon into the cup to protect the glass bulb thermal element from damage. The by hand; the escutcheon can be tightened against the clip should remain in place during installation of the sprinkler ceiling or wall by turning the escutcheon in a clockwise and be removed when the sprinkler system is placed in service. direction and removed by turning the escutcheon in a Sprinklers with 3/4" NPT and ISO7-1R3/4 inlets are supplied counter-clockwise direction. To install the Model CCP with a protective cap on the inlet that must be removed before cover plate, first remove the protective clip. Install the installation. Model CCP cover plate on the sprinkler by pressing or Use the following steps for installation: threading the cover plate into the cup by hand; the cov- 1. Cut a hole in the wall or ceiling directly in-line with the er plate can be tightened against the ceiling by turning outlet of the fitting. See the Installation Data table for the the cover plate in a clockwise direction and removed by recommended hole diameter based on the escutcheon turning the cover plate in a counter-clockwise direction. or cover plate option selected. 5. Remove the orange protective clip when placing the 2. Apply pipe joint compound or PTFE tape to the male sprinkler system in service. threads of the sprinkler's inlet fitting. 3. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table.The Mod- el F3R wrench is designed to be inserted into the groves in the sprinkler's wrench boss as shown in Fig. 13. The Model XLO2 wrench is designed to fit into the cup and engage the wrench boss as shown in Fig. 14. Do NOT wrench any part of the sprinkler assembly other than the wrench boss. When inserting or removing the wrench from the sprinkler, care should be taken to prevent dam- age to the sprinkler. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to maximum installation torque is 22 - 30 lb-ft (30—40 N-m) for 1" NPT and IS07-1 R1 sprinklers, and 14 - 20 lb-ft (19—27 N-m) for 3/4" NPT and ISO7-1 R3/4 sprinklers. 18. Installation Data Sprinkler Required Centerline of Sprinkler Model Suggested Hole Diameter in Installation Tube/Inlet to Finished Ceiling Escutcheon or Cover Plate Wall or Ceiling Wrench Vertical Dimension' Standard Escutcheon 2-1/8''(54 mm) F3R HB Extended Escutcheon 2-1/2"(64 mm) F3R F3QR56 Dry F1 Recessed Escutcheon 2-1/4"(57 mm) XLO2 Not Pendent Applicable FP Recessed Escutcheon XLO2 2-1/2"(64 mm) CCP Cover Plate XLO2 Standard Escutcheon 2-1/8"(54 mm) F3R 4-5/8"to 12-5/B" HB Extended Escutcheon 2-1/2"(64 mm) F3R (118 mm to 321 mm) F3QR56 Dry F1 Recessed Escutcheon 2-1/4"(57 mm) XLO2 cULus,NYC Horizontal 4-5/8"to 6-5/8" Sidewall FP Recessed Escutcheon 2-1/2"(64 mm) XLO2 (118 mm to 168 mm) F1 Recessed Escutcheon 2-1/4"(57 mm) XLO2 FM 4-5/8"to 12-5/8" FP Recessed Escutcheon 2-1/2"(64 mm) XLO2 (118 mm to 321 mm) F3QR56 Dry N/A 1-1/2"(38mm) F3R Not Applicable Upright *Note: Based on 5/8"(16 mm)centerline of sprinkler tube/inlet to defector vertical distance. Maintenance The Model F3QR56 Dry Sprinklers should be inspected and 4. Inlet Fitting: [Long — Standard Inlet Fitting][Short "PC — the sprinkler system maintained in accordance with NFPA 25. Wet Pipe Systems only] Do not remove the factory applied thermally sensitive wax fillet 5. Sprinkler Temperature Rating: See Temperature Ratings between the bulb supporting cup and the wrenching boss. Do Table not replace this wax with a substitute substance. 6. Sprinkler Finish: See Finish Combinations Table An Alternate substance may interfere with proper operation 7. Escutcheon/Cover Plate Finish:See Finish Combinations of the sprinkler. Do not clean sprinklers with soap and water, Table ammonia or any other cleaning fluids. Remove dust by using 8. Length: a soft brush or gently vacuuming. Replace any sprinkler which *For dry pendents and dry sidewalls: "A" Dimension has been painted(other than factory applied)or damaged in any is from face of tee to face of finished ceiling or wall in way. A stock of spare sprinklers should be maintained to allow 1/4" (6mm) increments. See Fig. 1 through Fig. 9. quick replacement of damaged or operated sprinklers. Prior *For dry uprights: Order dimension is from face of tee to installation, sprinklers should be maintained in the original to top of deflector in 1/4" (6mm) increments. See Fig. cartons and packaging until used to minimize the potential for 10. damage to sprinklers that would cause improper operation or Notes: non-operation. 1. For Dry Upright,customer is responsible for determining the Ordering Information correct deflector distance from structure above. Specify: 2. Length is based on normally gauged pipe thread"make-up" 1. Sprinkler: [Model F3QR56 Dry Pendent SIN R5714] of.600" (15mm) per ANSI B2.1 (approximately 7-1/2 threads). [Model F3QR56 Dry Horizontal Sidewall SIN R5734] [Model F2QR Dry Upright SIN R5724] Installation Wrench 2. Escutcheon/Cover Plate: [None][Standard escutcheon] Model F3R Sprinkler Wrench (Standard and HB escutcheons) [Model HB extended escutcheon][Model F1 recessed Model XLO2 Sprinkler Wrench(FP Recessed and CCP escutcheon][Model FP recessed escutcheon][Model Concealed) CCP cover plate—pendent only] 3. Inlet Threads: [1" NPT][IS07-1R1][3/4" NPT][IS07- 1 R3/4] The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. * Recycled ® (800)431-1588 Sales Offices tiff Paper Re 1 i a b 1 e (800j 848-6051 Sales Fax Revision lines indicate updated or new data. 914 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.03/22 P/N 9999970175 • Bulletin 034 April 2023 MI ReilabiModel G5 Series Sprinklers e Standard Spray, Flat Concealed Pendent Available with Gasketed Cover Plate Features • Standard Coverage,Concealed Pendent(K2.8,4.2.5.6. &8.0 [40,60,80,& 115 metric]) ilk • Flat concealed cover plate available in a variety of finishes. "^,i • Available with Stainless Steel Clad cover plate(see Table I). • 3/4-inch(19 mm)cover plate adjustment. Lmoor't. . • Cover plate available with optional gasket. Product Description Model G5 Cover Plate Model G5 Cover Plate with QR Gasket Model G5 series sprinklers are standard coverage,flat plate concealed sprinklers designed for installation in accordance with NFPA 13 and FM Global Property Loss Prevention Data Sheets.All Model G5 series sprinklers use a fusible-link operating element. The sprinklers are offered with a standard Model G5 cover plate, L... a Model G5 cover plate with a quick-response(QR)gasket,or a Model G5 cover plate with a standard-response(SR)gasket. Model G5 sprinklers with a gasketed cover plate are intended for use in dust free environments such as clean rooms. Model G5 Cover Plate with SR Gasket Model G5 sprinklers must only be used with the Model G5 cover Note:Gasket material is silicone rubber,available in white only. plate listed or approved with the sprinkler.Table A provides a summary of available Model G5 series sprinklers,along with Listing and Approval information for each sprinkler and cover plate combination. Model G5 Series Sprinkler Summary Table A K-Factor Listin s Sprinkler Cover Plate g Max.Working Sprinkler Model 9PPslvs Model and Sensitivity Pressure Identification O./min/barnApprovals psi(bar) Number(SIN) G5 cULus QR G5-28 2.8 FM SR (40) G5 OR Gasket cULus QR 175(12) RA3411 G5 SR Gasket cULus, FM SR G5 G5-42 (60) G5 OR Gasket cULus QR 175(12) RA3413 G5 SR Gasket cULus SR cULus OR 250(17) G5 FM, LPCB,VdS,CE, 5.6 UKCA SR 175(12) G5-56 (80) G5 QR Gasket cULus QR 250(17) RA3415 G5 SR Gasket cULus SR 250(17) FM SR 175 (12) G5 G5-56 300 ($�) G5 QR Gasket cULus QR 300 (21) RA4014 G5 SR Gasket cULus SR 8.0 G5 G5-80 (115) G5 QR Gasket CULus QR 175(12) RA3412 G5 SR Gasket cULus SR G5-80F Si0 G5 FM SR 175 (12) RA3417 (115) G5 SR Gasket www.reliablesprinkler.com Model G5-28 Standard Coverage,Concealed Pendent Sprinkler SIN RA3411 Technical Specifications Temperature Ratings Style:Flat Concealed Pendent Ordinary ru Threads:t/,"NPT or ISO 7-1 R'/r 165°F(74°G)(Sprinkler) Nominal K-Factor:2.8(40 metric) [135"F(57`C)(Cover Plate)] Max.Working Pressure: 175 psi(12 bar) Intermediate Material Specifications 212°F(100°C)(Sprinkler) Fusible Link:Beryllium Nickel [165°F(74°C)(Cover Plate)) Sprinkler Body:Brass Alloy Levers:Bronze Alloy Sensitivity fttolt � Yoke:Brass Alloy (See Table B) Sealing washer:Nickel with PTFE Cover Plates Load Screw:Bronze Alloy Model G5 Towers:Copper Alloy Model G5 OR Gasket(cULus only) gS Pins:Stainless Steel Model G5 SR Gasket " - Deflector:Bronze Alloy Cover Plate Finishes " Cup:Steel (See Table I) Sprinkler Wrench Model W3 Model FC Listings and Approvals cULus Listed(Light Hazard only) FM Approved Model G5-28 Sprinkler Components and Dimensions Figure 1 2-5/16" (58 mm) Dia. Threads Body illiTi Ceiling ower s Fusible Link 3/4"(19 mm)Max. - Deflector(retracted) Cover Plate Adjustment 3(16"(5 mm) • Pin(extended) Deflector(extended) rv53 T Model G4/G5 Cover Plate --3-5/16"(84 mm)Dia.— Ceiling Model G5-28 Sprinkler Sensitivity Table B - Listing or Approval Agency Cover Plate Model cULus FM G3 OR SR G5 OR Gasket CR -- G5 SR Gasket SR SR QR: Quick-response SR:Standard-response Bulletin 034 Reliable Page 2 of 9 April 2023 www.reliablesprinkler.com Model G5-42 Standard Coverage,Concealed Pendent Sprinkler SIN RA3413 Technical Specifications Temperature Ratings Style:Flat Concealed Pendent Ordinary Threads:1/2"NPT or ISO 7-1 R'/2 185°F(74*C)(Sprinkler) Nominal K-Factor:4.2(60 metric) [135*F(57*C)(Cover Plate)] Max.Working Pressure: 175 psi(12 bar) intermediate , y w e p' Material Specifications 212°F(100°C)(Sprinkler) Fusible Link:Beryllium Nickel [165°F(74°C)(Cover Plate)] if ,‘ Sprinkler Body:Brass Alloy Sensitivity 4 Levers:Bronze Alloy (See Table C) ` , Yoke:Brass Alloy Cover Plates Sealing washer:Nickel with PTFE Model G5 Load Screw:Bronze Alloy Model G5 OR Gasket Towers:Copper Alloy Pins:Stainless Steel Model G5 SR Gasket rF Deflector:Bronze Alloy Cover Plate Finishes Cup:Steel (See Table I) " Sprinkler Wrench Model W3 Model FC Listings and Approvals cULus Listed(Light Hazard only) Model G5-42 Sprinkler Components and Dimensions Figure 2 2-5/16" (58 mm) Dia. Threads--�---_- = _ Bod �z l Cup i M Ii�.I PSI Ceiling . -�_ Tower __ __■ ` ' '� Fusible Link 3/4"(19 mm)Max. Deflector(retracted) / Cover Plate Adjustment 3/16"(5 mm) Pin(extended)_/ „ , ' } i J' ��-•- Deflector(extended) Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-42 Sensitivity Table C Cover Plate Model Listing or Approval Agency cULus G5 QR G5 OR Gasket QR G5 SR Gasket SR OR:Quick-response SR: Standard-response Bulletin 034 April2023 Reliabld Page 3 of www.reliablesprinkler.com Model G5-56 Standard Coverage,Concealed Pendent Sprinkler SIN RA3415 Technical Specifications Temperature Ratings Style:Flat Concealed Pendent Ordinary Threads: V2"NPT or ISO 7-1 RVz 165`F(74`C)(Sprinkler) f r)w, Nominal K-Factor:5.6(80 metric) [135°F(57-C)(Cover Plate)] s Max.Working Pressure: Intermediate r, 175 psi(12 bar) 212°F(100°C)(Sprinkler) Pi i* v' • 250 psi(17 bar)(cULus only) [165°F(74°C)(Cover Plate)] u 1• Material Specifications E r Fusible Link:Beryllium Nickel y • ry Sensitivity 1 Sprinkler Body:Brass Alloy (See Table D) I Levers:Bronze Alloy , Yoke:Brass Alloy Cover Plates Model G5 Sealing washer:Nickel with PTFE Model G5 OR Gasket(cULus only) Load Screw:Bronze Alloy Model G5 SR Gasket(cULus and FM only) Towers:Copper Alloy Pins:Stainless Steel Cover Plate Finishes °•', �. Deflector:Bronze Alloy (See Table I) ,IV, Cup:Steel Sprinkler Wrench ,,4„ .1 Model W3 Model FC Listings and Approvals cULus Listed(Light&Ordinary Hazard only) FM Approved LPCB Approved VdS Approved[165°F(74°C)only] CE Listed(2831-CPR-52062) UKCA:0832-UKCA-CPR-S5045 Model G5-56 Sprinkler Components and Dimensions Figure 3 2-5/16" (58 mm)-- Dia. Threads Body ih ! J MI Ceiling Tower e:>. as Fusible Link 3/4"(19 mm)Max. % -- Deflector(retracted)-�f' Cover Plate Adjustment "";" 3/16"(5 mm) Pin(extended)J l i Deflector(extended)--- cux, - 1 Model G4/G5 Cover Plate 3-5/16"(84 mm) Dia.-- Ceiling Model G5-56 Sensitivity Table D Listing or Approval Agency Cover Plate Model cULus FM LPCB,VdS,CE, UKCA G5 OR SR SR G5 QR Gasket QR -_ G5 SR Gasket SR SR OR: Quick-response SR: Standard-response Bulletin 034 April 2023 Reliable Page 4 of 9 www.relic blesprinkler.com Model G5-56 300 Standard Coverage,Concealed Pendent Sprinkler SIN RA4014 Technical Specifications Temperature Ratings Style:Flat Concealed Pendent Ordinary Threads:V?"NPT or ISO 7-1 RV, 165`F(74°C)(Sprinkler) Nominal K-Factor:5.6 80 metric - Max.Working Pressure:300psi( t eF(57`G)(Cover Plate)] (21bar) Intermediate material Specifications 212°F(100°C)(Sprinkler) " Fusible Link:Beryllium Nickel [1651-(74°C)(Cover Plate)] Sprinkler Body:Brass Alloy Levers:Bronze Alloy Sensitivity Yoke:Brass Alloy (See Table E) Sealing washer:Nickel with PTFE Cover Plates Load Screw:Bronze Alloy Towers:Copper Alloy Model G5 Pins:Stainless Steel Model G5 QR Gasket h i Deflector:Bronze Alloy Model G5 SR Gasket Cup:Steel Cover Plate Finishes (See Table I) Sprinkler Wrench Model W3 Model FC Listings and Approvals cULus Listed(Light&Ordinary Hazard only) Model G5-56 300 Sprinkler Components and Dimensions Figure 4 2-5/16" (58 mm)— Dia. Threads Body cup s . C ' m Ceiling Tower .►�_�_� Fusible Link 3/4"(19 mm)Max. Deflector(retracted) Cover Plate Adjustment 3/16"(5 mm) Pin(extended) ' Deflector(extended) Model G4/G5 Cover Plate —3-5/16"(84 mm)Dia.— Ceilin9 Model G5-56 300 Sensitivity Table E Cover Plate Model Listing or Approval Agency cULus G5 QR G5 OR Gasket OR G5 SR Gasket SR QR:Quick-response SR: Standard-response Bulletin 034 April 20 3 Reliable Page 5 of 9 www.reliablesprinkler corn Model G5-80 Standard Coverage,Concealed Pendent Sprinkler SIN RA3412 Technical Specifications Temperature Ratings Style:Flat Concealed Pendent Ordinary .6 Threads:3/4"NPT or ISO 7-1 R3/4 165°F(74°C)(Sprinkler) • ,, Nominal K-Factor:8.0(115 metric) [135"F(57`C)(Cover Plate)] Max.Working Pressure: 175 psi(12 bar) IntermediateI Material Specifications 212°F(100°C)(Sprinkler) 1.1 Fusible Link:Beryllium Nickel [165-F(74"C)(Cover Plate)] • t�? t^ Sprinkler Body:Brass Alloy ,*t w - Levers:Bronze Alloy Sensitivity 1 Yoke:Brass Alloy (See Table F) Sealing washer:Nickel with PTFE Cover Plates • ,�+ Load Screw:Bronze Alloy Model G5 ' -w2 o Towers:Copper Alloy Model G5 QR Gasket . t , y,•! '0 Pins:Stainless Steel Model G5 SR Gasket Deflector:Bronze Alloy Cup:Steel Cover Plate Finishes (See Table I) .. Sprinkler Wrench Model W3 Model FC Listings and Approvals clJLus Listed(Light&Ordinary Hazard only) Model G5-80 Sprinkler Components and Dimensions Figure 5 2-5/16" (58 mm) Dia. Threads — Body ii I■ ■I Cup Ceiling 'r �'1 Tower =r_. _a___ w ` __1"�__`_A_ Fusible Link 3/4"(19 mm)Max. • "- t Deflector(retracted) Cover Plate Adjustment 3116"(5 mm) Pin(extended) / 1 .,__,; --___T Deflector(extended)---,:�^_, Model G4/G5 Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model G5-80 Sensitivity Table F Listing or Approval Agency . Cover Plate Model cULus G5 QR G5 QR Gasket OR G5 SR Gasket SR QR:Quick-response SR:Standard-response Bulletin 034 Page 6 of 9 April 2023 Reliable www.reliablesprinkler.com Model G5-80F Standard Coverage,Concealed Pendent Sprinkler SIN RA3417 Technical Specifications Temperature Ratings Style:Flat Concealed Pendent Ordinary Threads:3/4"NPT or ISO 7-1 R3/, 165°F(74°C)(Sprinkler) Nominal K-Factor:8.0(115 metric) [135°F(57°C)(Cover Plate)] Max.Working Pressure: 175 psi(12 bar) Intermediate Material Specifications 212°F(100°C)(Sprinkler) `_ z' Fusible Link:Beryllium Nickel [165°F(74"C)(Cover Plate)] km.:!, Sprinkler Body:Brass Allo Y Sensitivity Levers:Bronze Alloy Standard Response y - • Yoke:Brass Alloy Cover Plates Sealing washer;Nickel with PTFE Model G5 Load Screw:Bronze Alloy Model G5 SR Gasket �' - Towers:Copper Alloy • �• Pins:Stainless Steel Cover Plate Finishes Deflector:Stainless Steel (See Table I) Cup:Steel Sprinkler Wrench Model W3 �`, Model FC Listings and Approvals FM Approved Model G5-80F Sprinkler Components and Dimensions Figure 6 2-5/16' (58 mm)-- Dia. Threads Body iiisr Cup AIM�j�' Ceiling Tower �i►� 4 Fusible Link 3!4°(19 mm)Max. _ Deflector(retracted) Cover Plate Adjustment 3/16°(5 mm) Pin(extended) Deflector(extended) ,,,„.(--- :a Model G4/G5 Cover Plate --3-5/16"(84 mm)Dia. Ceiling Model G5-80F Sensitivity Table G Cover Plate Model Listing or Approval Agency FM G5 SR GSSR Gasket SR SR: Standard-response Bulletin 034 April 2023 Reliable Page 7 of 9 www,reliablesponkler.com Installation Dimensions and Cover Plate Information Table H Min.to Max. Min.to Max. Cover Plate Recommended Cover Plate Face of Fitting Dropped Cover Plate Mole• Diameter in Deflector Temperature Cover Plate Diameter Adjustment to Ceiling Distance Rating Model' Inch Inch Ceilingt't (mm) Inch (mm) Inch below Ceiling °F (mm) (mm) Inch (°C) • (mm) G5 3-u/16 (84) 135`F' (57°C) GS OR Gasket° 3-11/16 (94) 2-5/e 3/4 1-1/2 to 2-1/4 1/4 to 1 (67) (19) (38 to 57) (6 to 25) or G5 SR Gasket2t 4 165°F > (101 mm) (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation,A 1/2"x 1/2"brass nipple extension(Reliable P/N 6999991900)is available to assist with replacement of Reliable Model G4A sprinklers. 2. Model G5 QR Gasket and Model G5 SR Gasket cover plates are sold as assembled units including both the cover plate and gasket.Model G5 QR Gasket and Model G5 SR Gasket cover plates and gaskets are not interchangeable. 3. For use with 165°F(74°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F(38°C). 4. For use with 212°F(100°C)temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F(66°C). Cover Plate Finishestlll:l Table I Standard Finishes Special Application Finishes Listing & Approval Agencies White Paint Off-White Paint Individual Model G5 series sprinkler may be listed or approved by Chrome14t Black Paint the following agencies: Custom Color Paint(Specify)(3) • Underwriters Laboratories, Inc. and UL Canada(cULus) Raw Brass(Lacquered) Listing Category:Sprinklers,Automatic and Open Bright Brasst4 Guide Number: NI p Finished Bronze 44) FM Approvals Satin Chrome(4) • pp ovals(FM) Stainless Steel CIad15j • Loss Prevention Certification Board(LPCB) Custom Printed • VdS Schadenverhutung GmbH (VdS) Notes: • EC-Certificate of Conformity 0832-CPD-2062(GE) • 1. Paint or any other coating applied over the factory finish will void all UKCA EN12259-1 : 1999+A3:2006 approvals and warranties. See Table A and the individual sprinkler data sheets in this Bulletin 2. Cover plates do not carry corrosion resistant listings or approvals. for listings and approvals applicable to each sprinkler. 3. Custom color paint is semi-gloss unless specified otherwise. 4. Not listed for use with OR sealing gasket. 5. Stainless steel clad cover plates are Type 316 Stainless Steel on the Installation finished side and C102 Copper Alloy on the back side. Model G5 series sprinklers are intended to be installed in accordance with NFPA 13, FM Global Property Loss Prevention Application Data Sheets,and the requirements of applicable authorities Model G5 series sprinklers are standard coverage,flat plate having jurisdiction. Model G5 series sprinklers must not be installed in ceilings with positive pressure in the space above. concealed pendent sprinklers.The sprinklers are intended for Ensure that the 4 slots in the cup are open and unobstructed use in accordance with NFPA 13 and FM Global Property Loss following installation. Prevention Data Sheets, as well as the requirements of the applicable approval agencies. Model G5 series sprinklers are shipped with a wrench-able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model G5 series sprinklers are available as either Quick-response (OR)or Standard-response(SR)depending on the approval Model G5 series sprinklers can be installed without removing agency and cover plate selected. the wrench-able protective cap using the Model W3 wrench. Alternatively, Model G5 series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap Model G5 series sprinklers use Model G5 flat cover plates. Model during installation of the sprinkler.The use of any other wrench G5 QR Gasket and G5 SR Gasket cover plates are available to to installed Model G5 series sprinklers is not permitted and may limit air and dust movement through the ceiling. damage the sprinkler. Bulletin 034 Page 8 of 9 April 2023 Rol— lam www.reliablesprinkler.com 4 1�' hN Chill) It..„ .„, aiw.. [[ 11 ISModel FC For use with Model G5 Series sprinklers Model W3 without wrench-able cap installed For use with Model G5 Series sprinklers with wrench-able cap installed Fully insert the Model W3 wrench over the cap until it reaches Replace any sprinkler or cover plate which has been painted(other the bottom of the cup,or the Model FC wrench over the sprinkler than factory applied). Properly installed Model G5 cover plates will until the wrench engages the body. Do not wrench any other have an air gap that is required for proper operation, do not seal part of the sprinkler/cup assembly. The Model W3 and FC the gap or paint the cover plates. Model G5 series sprinklers have wrenches are designed to be turned with a standard 1/2"square holes in the cup that must remain unobstructed. drive.Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended Replace any sprinkler which has been damaged. A stock of spare nstallation torque is specified in Table J. sprinklers should be maintained to allow quick re-placement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation Installation Torque during a fire event. Table J Recommended Installation Guarantee Sprinkler Threads Torque (min.—max.) ft.lb For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, N m and conditions,visit www.reliablesprinkler.com. Y2" NPT or l507-1 Rt/2 8-18 11-24 %"NPT or IS07-1 R3/4 14-20 19-27 Patents Do not exceed the maximum recommended torque. Exceeding the Model G5 series sprinklers may be covered by one or more of the maximum recommended torque may cause leakage or impairment following patents: of the sprinkler. Use care when inserting or removing the wrench U.S. Patent 6,554,077, U.S. Patent 7,275,603, U.S. Patent from the sprinkler to avoid damage to the sprinkler. 8,776.903. U S Patent 9,248,327 Install the cover plate by hand,pushing and then turning the cover Ordering Information in the clockwise direction until it is tight against the ceiling. For Specify the following when ordering. Model G5 QR Gasket and Model G5 SR Gasket cover plates, the gasket should be attached to the flange of the cover plate skirt Sprinkler only. Do not glue the gasket in place or allow the gasket to overlap • Model[G5-28][G5-42][G5-56] [G5-56 300] both the cover plate and the flange of the skirt. [G5-80] [G5-80F] • Temperature Rating[165°F(74°C)][212°F(100°C)] Maintenance • Threads[NPT or ISO 7-1] Reliable Model G5 series sprinkler should be inspected and the Cover Plate sprinkler system maintained in accordance with NFPA 25, as well • Model[G5, G5 QR Gasket, G5 SR Gasket] as the requirements of any Authorities Having Jurisdiction. • Finish (See Table I) Prior to installation, sprinklers should remain in the original cartons Sprinkler Wrench and packaging until used. This will minimize the potential for • Model W3 damage to sprinklers that could cause improper operation or non- • Model FC operation. Do not clean sprinklers with soap and water,ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without "' touching the sprinkler. r` rn m rn rn rn z CIBulletin 034 April 2023 Rele is Page 9 of 9 www.reliablespankler.com Bulletin 006 May 2022 _I Reliable° Model RFC Series Residential Sprinklers Flat Concealed Pendent cULus Listed Features M • cULus Listed as Residential Sprinklers , ,,, • Push-On cover plate installation • Low water flow requirements k 1 Pit Olt Product Description Model RFC30&RFC3OLL Model RFC43&RFC43LL Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R,or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in y= accordance with UL 199. In addition, Model RFCLL Series sprinklers are cULus certified for Health Effects to NSF/ANSI/ '- CAN 600,cULus certified less than 0.25% Lead Content to A , y.� NSF/ANSI 372 Annex G, and Australian WaterMark certified. i IIIIIV.:. Model RFC Series sprinklers are offered with either a 165°F Model RFC49&RFC49LL Model RFC58 (74°C)or 212°F(100°C)temperature rated fusible-link operating element.Sprinklers with a 165°F (74°C)temperature rating are ordinary temperature classification and are listed 11114 for use with a 135°F(57°C)temperature rated cover plate. Sprinklers with a 212°F(100°C)temperature rating are , intermediate temperature classification and are listed for use irrar, with a 165°F(74°C)temperature rated cover plate. Model RFC Series sprinklers are installed with a Model G5 �,. cover plate. Model G5 cover plates are installed by pushing the cover plate into the cup and turning in the clockwise direction until it is tight against the ceiling. Model RFC30, RFC3OLL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" Model RFC76 Model G5 Cover Plate (13 mm)of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4"(19 mm)of cover plate adjustment. Model G5 cover plates are available in a variety of finishes as listed in Table H. Table A Sprinkler Model Nominal K-Factor Max.Coverage Area Listings& Sprinkler Identification gpm/psi"2(I/min/bare?) ft x ft(m x m) Approvals Number(SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA0611 RFC3OLL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA3211 RFC43 4.3(62) 20 x 20 (6.1 x 6.1) cULus RA0612 RFC43LL 4.3 (62) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20 x 20 (6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20 x 20 (6.1 x 6.1) cULus RA0613 RFC76 7.6(109) 20 x 20(6.1 x 6.1) cULus RA0618 cULus: cULus listed for Safety to ANSI/UL199 LL: cULus certified for Health Effects to NSF/ANSI/CAN 600 cULus certified less than 0.25%Lead Content to NSF/ANSI 372 Annex G. WMCS:Australian WaterMark certified,certificate number 23347. www.reliablesprin kler.com Model RFC30& RFC3OLL Residential Sprinklers RFCRFC30LL:L:StRA A S3211 11 Technical Specifications Sensitivity Style:Flat Concealed Pendent Fast-response , Threads:1/2"NPT or ISO 7-1 R1/2 w .^i""'°" Nominal K-Factor:3.0(43 metric) Temperature Rating Max.Working Pressure: 175 psi(12 bar) Ordinary: Nv o„ Min.Spacing:8 ft.(2.4 m) 165°F(74°C)sprinkler ° [135"F(57°C)cover plate] - Material Specifications Intermediate: Thermal Sensor:Nickel Alloy Solder Link 212°F(100°C)sprinklers G Sprinkler Body:Brass Alloy (165°F(74°C)cover plate] Levers:Bronze Alloy Yoke:Brass Alloy Cover Plate ` Sealing Assembly:Nickel Alloy with PTFE Model G5 Cover Plate Load Screw:Bronze Alloy Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model FC(without wrench-able cap) Deflector Bronze Alloy Model W3(with wrench-able cap) 0 , Cup:Steel ;1: _ Listings and Approvals' Bottom View Cover Plate Finishes cULus Listed to UL 199 f. (See Table H) *Note:RFC3OLL is also cULus certified for Health Effects to NSF/ANSI/CAN 600,cULus certified less than 0.25%Lead Content to NSF/ANSI 372 Annex G, and Australian WaterMark certified(certificate number 23347). Model RFC30&RFC3OLL Sprinkler Components and Dimensions Figure 1 2-5/16" Threads I------ (58 mm) -- -� Cup Dia. Body--- Cup--,,,,.., r Tower— �� 2-5/8"(57 mm) HEtI Deflector( tracted) —t (5 mm) Pin(extended) - -- � -� _ - i i Deflector(extended) �_fr rzcax-�z, j J 3-5/16" Model G5 Cover Plate --- — (84 mm) — ---- --Ceiling Dia. Model RFC30 and RFC3OLL Sprinkler Hydraulic Design Criteria Table B Minimum Flow and Residual Pressure(I Max.Coverage Area tzf Ordinary Temperature Intermediate Temperaturelst 1 ft.x ft. Flow Pressure Flow Pressure (m x m) gpm psi gpm psi (I/min) (bar) (I/min) (bar) 12x12 9 9.0 9 9.0 (3.6 x 3.6) (34) (0.62) (34) (0.62) 14 x 14 10 11.0 (4.3 x 4.3) (38) (0.76) -- -- Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table B above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage arca dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed, 3. Intermediate temperature listing applies to SIN RA0611 only;not applicable to low-lead version. Bulletin 006 Page 2 of 8 May 2022 Rellabi www.reliablesprinkleccom Model RFC43&RFC43LL Residential Sprinklers RFC43: SNRA0612 RFC43LL: SNRA3212 Technical Specifications Sensitivity Style:Flat Concealed Pendent Fast-response Threads:1/2"NPT or ISO 7-1 R1/2 Nominal K-Factor:4.3(62 metric) Temperature Rating Max.Working Pressure: 175 psi(12 bar) Ordinary: 165°F(74°C}sprinkler Min.Spacing:8 ft.(2.4 m) 11351F(57°C)cover plate] `? Material Specifications Intermediate: Thermal Sensor:Nickel Alloy Solder Link 212°F(100°C)sprinkler Sprinkler Body:Brass Alloy [165°F(74°C)cover plate] I 11 Levers:Bronze Alloy Cover Plate Yoke:Brass Alloy Model G5 Cover Plate Sealing Assembly:Nickel Alloy with PTFE .r . Load Screw:Bronze Alloy Towers:Copper Alloy Sprinkler Wrench �. Pins:Stainless Steel Model FC(without wrench-able cap) 1t '; Model W3(with wrench-able cap) Deflector:Bronze Alloy rA" Cup:Steel Bottom View 0" `*/7 .} Listings and Approvals' Cover Plate Finishes cULus Listed to UL 199 ' (See Table H) *Note:RFC43LL is also cULus certified for Health Effects to NSF/ANSI/CAN 600,cULus certified less than 0.25%Lead Content to NSF/ANSI 372 Annex G, and Australian WaterMark certified(certificate number 23347). Model RFC43 &RFC43LL Sprinkler Components and Dimensions Figure 2 2.5/16" Threads — (58 1---- mm) — Body- Cup Dia. Cup Tower _- ` . .. ( r 1-3/4"(44 mm)+/- 1/4"(6 mm)ri i. I- 2-5/B"(67 mm) Fusible Link --- Nominal lace of fitting to ceiling Hole in Ceiling 1 I ( I (_ f Deflector(refracted)—__ --__-- ._ ��, I 3116" i Pin(extended) — "^.� °iG, L. ) y t i f j -_-_: - (5 m Deflector(extended) s u;; _ ` 1-— ----r r 3 5/16 f Model G5 Cover Plate - - I— 84 mm ( ) ---._.._..___—i --Ceiling Dia. Model RFC43&RFC43LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure(1) Max.Coverage Area(2) Ordinary Temperature Intermediate Temperature ft.x ft. Flow Pressure Flow (m x m) gpm psi Pressure gpm (I/min) (bar) psi 15 x 15 12 (I/milmin) (bar) (4.6 x 4.6) (45) 7 8 12 7.8 16 x 13 (0.54) (45) (0.54) 9 (4.9 x 4.9) (49) 13 9 18 x 18 (0.63) (49) 18 17.5 (0.6 3) (5.5 x 5.5) (68) (1.21) -- 20x20 21 . 23.8 (6.1 x 6.1) (79) ( .64 1.64 ) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table C above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 May 2022 Reliable, Page 3 of 8 www.ref iablesprin kleccom Model RFC49&RFC49LL Residential Sprinklers RFC49:SNRA0616 RFC49LL: SNRA3216 Technical Specifications Sensitivity Style:Flat Concealed Pendent Fast-response Threads: 1/2"NPT or ISO 7"1R1/2 r a Nominal K-Factor:4.9(71 metric) Temperature Rating Max.Working Pressure: 175 psi(12 bar) Ordinary: Min.Spacing:8 ft.(2.4 m) 165"F(74"C)sprinkler 1135°F(57°C)cover plate] Material Specifications Intermediate: Thermal Sensor:Nickel Alloy Solder Link 212°F(100"C)sprinkler :"" Sprinkler Body:Brass Alloy [165°F(74°C)cover plate] Levers:Bronze Alloy Yoke:Brass Alloy Cover Plate `d" ',` "w Sealing Assembly:Nickel Alloy with PTFE Model G5 Cover Plate Load Screw:Bronze Alloy Towers:Copper Alloy Sprinkler Wrench Pins:Stainless Steel Model FC(without wrench-able cap) Deflector:Bronze Alloy Model W3(with wrench-able cap) `3- J •4 Cup:Steel Bottom View 1 Cover Plate Finishes Listings and Approvals° !�` _ cULus Listed to UL 199 (See Table H) `Note:RFC49LL is also cULus certified for Health Effects to NSF/ANSI/CAN 600,cULus certified less than 0.25%Lead Content to NSF/ANSI 372 Annex G, and Australian WaterMark certified(certificate number 23347). Model RFC49&RFC49LL Sprinkler Components and Dimensions Figure 3 2-5/16" Threads 1--•- (58 mm) ---._I Cup Dia. Body - - -- Cup ---Tower - - — — - - - 1-3/4"(44 mm)+/-1/4"(6 mm) —I— ) 2-518"(67 mm) Fusible Link — I Nominal face of fitting to ceiling i_ f Hole in Ceiling Deflector(retracted) _ -- 1 [ 3/16" —_._ Pin(extended) ° °, L— — I(5 mm) Deflector(extended) 21 3-5/16" Model G5 Cover Plate--- ---- (84 mm) 1 -Ceiling Dia. Model RFC49&RFC49LL Sprinkler Hydraulic Design Criteria Table D Minimum Flow and Residual Pressure III Max. Coverage Area RIOrdinary Temperature Intermediate Temperature ft.x ft. Flow Pressure Flow (m x m) gpm psi Pressure gpm psi (I/min) (bar) (I/min) (bar) 16 x 16 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18 x 18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20 x 20 20 16.7 21 (75.7) 1(6.1 x6.1) (1.15) (79.5) (1.2727) Notes: 1, For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table D above and(2)the flow required to achieve a mini- mum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max,coverage area listed. Bulletin 006 � May 2022 e1d Page 4 of 8 www.reliablesprinkler.com Model RFC58 Residential Sprinkler SIN RA0613 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) Threads; 1/2"NPT or ISO 7-1 R1/2 Nominal K-Factor:5.8(84 metric) Sensitivity Max.Working Pressure;175 psi(12 bar) Fast-response - ( Min.Spacing:8 ft.(2-4 m) Temperature Ratings .� Material Specifications Ordinary: Thermal Sensor:Nickel Alloy Solder Link 165"F(74°C)sprinkler Sprinkler Body;Brass Alloy [135°F(57°C)cover pinto] Levers: Bronze Alloy Yoke:Brass Alloy Intermediate: Sealing Assembly:Nickel Alloywith PTFE (165°F (100°C)74°C) sprinkler (165°F(74°C)cover plate) Load Screw: Bronze Alloy Towers:Copper Alloy Cover Plate Pins:Stainless Steel Model G5 Cover Plate Deflector:Chrome Plated Bronze Alloy Cup:Steel Sprinkler Wrench Bottom View ys .i„0 Model FC(without wrench-able cap) Model W3(with wrench-able cap) Listings and Approvals cULus Listed to UL 199 Model RFC58 Sprinkler Components and Dimensions Figure 4 2-5/16" Threads — (58 mm) -- ---Cup Dia. Body Cup Tower Fusible Link 1-7/8" 7 -- — 2-5 8" 67/8 (48 mm)+/ 3/8 (9 mm) i � Ti ( / ( mm) Nominal face of fitting to ceiling Hole in Ceiling Deflector(retracted) _ - _ 3/16" Pin(extended) i fi I 1_ (5 mm) PA'FlGUA ,___ Deflector(extended) — — -1—" 35/16 Model G5 Cover Plate -- 84 mrn - I- _ ( ) — -- Ceiling Dia. Model RFC58 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressures 1s Max.Coverage Area at F1ow Pressure ft.x ft. gpm si (m x m) (I/min) P -- (bar) 16 16 (4.9 x 4.9) (60.6) (0.53) 3) 18 x 18 18 (5.5 x 5.5) (68.1) 96 20x20 ( ,9J 20 1 (6.1 x 6.1) 19 (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table E above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow far the next larger max.coverage area listed. Bulletin 006 May 2022 Rellabl Page 5 of 8 www.rolia tiles pri n k l er.com Model RFC76 Residential Sprinkler SIN RA0618 Technical Specifications Cover Plate Finishes style:Flat Concealed Pendent (See Table H) Threads:3/4"NPT or ISO 7-1R3/4 ^^"'r"°^ Nominal K°Factor:7.8 109 metric) ( Sensitivity Max,Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2,4 m) Temperature Ratings Material Specifications Ordinary: - Thermal Sensor:Nickel Alloy Solder Link 165°F(74°C)sprinkler Sprinkler Body:Brass Alloy [135°F(57'c)cover plate) Levers:Bronze Alloy Intermediate: Yoke:Brass Alloy 212°F(100°C)sprinkler Sealing Assembly:Nickel Alloy with PTFE [165°F(74°C)cover plate] ' Load Screw:Bronze Alloy Towers:Copper Alloy Cover Plate Pins:Stainless Steel Model G5 Cover Plate Deflector:Bronze Alloy - Cup:Steel Sprinkler Wrench : Model FC(without wrench-able cap) Bottom View Model W3(with wrench-able cap) '•, �/ Listings and Approvals cULus Listed to UL 199 Model RFC76 Sprinkler Components and Dimensions Figure 5 2-5 Threads Cup " (58 mm) Dia. Body _ Cup __ wer Fus bole Link � I' 1-7/6"(48 mm)t+/_3/8"(9 mm) II —2-5/8"(67 mm) mil �I'I Nominal face of fitting to ceiling �A I[ Hole in Ceiling Deflector(retracted) .__.__ I'I 3/16" Pin(extended) ",; - (5 mm) ti E{ ma n Deflector(extended) g_4I.E55 a6 T 3-5/16" Model G5 Covsr Plato ---- - (84 mm) .-.- -Ceiling Dia. Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure(') Max.Coverage Area(2) Flow ft.x ft. Pressure (m x m) gpm psi (I/min) (bar) 16 x 16 21 (4.9 x 4.9) (79.5) 7 (0.52) 18 x 18 24 (5.5 x 5.5) (90.8) (0.68)9 20 x 20 (6.1 x 6.1) 34 20 (128.7) (1.4) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of:(1)the flow listed in Table E above and(2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 May 2022 flellabld Page 6 of 8 www.rel i a b l e s p ri n k le c co m Cover Plate Finishesltl Table H Standard Finishes Special Application Finishes White Paint Off White Paint Black Paint Raw Brass Chrome Bright Brass Finished Bronze Custom Color Paint121 Satin Chrome Stainless Steel Cladt't Custom Printed Notes; 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi-gloss.unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side.Cover plates are not listed or approved as corrosion resistant. Installation Dimensions Table J Recommended Min.to Min.to Max. Sprinkler Cover Cover Plate Cover Plate Max. Face Dropped Deflector Cover Plate Model Hole Diameter Plate Diameter Adjustment of Fitting to Distance below Temperature Model inch (mm) in Ceiling inch(mm) inch(mm) Ceilings t Ceiling Rating inch(mm) inch(mm) RFC30, RFC30LL, 135°Fm RFC43, G5 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC43LL, (84) (67) (13) (38 to 51) (13 to 25) or 165°Fm RFC49, (74°C) RFC49LL RFC58, G5 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 13or 16(57°C) RFC76 (84) (67) (19) (38 to 57) (6 to 25) or 1(74°C)C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up.Verify dimensions based on fitting and thread sealing method prior to installation.A 1/2"x 1/2"brass nipple extension(Reliable P/N 6999991900)is available where necessary for replacement of existing sprinklers. 2. For use with 165°F(74°C)temperature rated sprinklers where the maximum ceiling temperature does not exceed 100°F(38°C). 3. For use with 212°F(100°C)temperature rated sprinklers where the maximum ceiling temperature does not exceed 150°F(66°C). Installation Model RFC series sprinklers are intended to be installed in Note:When used with gasketed fittings,follow fitting accordance with NFPA 13, NFPA 13R,or NFPA 13D,as well as manufacturer's installation instructions regarding tightening to the requirements of applicable authorities having jurisdiction. achieve a leak-free connection. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Model RFC series Do not exceed the maximum recommended torque. Exceeding sprinklers are shipped with a wrench-able protective cap that the maximum recommended torque may cause leakage or should remain on the sprinkler until the sprinkler system is placed impairment of the sprinkler. Use care when inserting or removing in service following construction, the wrench from the sprinkler to avoid damage to the sprinkler. Model RFC series sprinklers can be installed without removing Install the cover plate by hand by pushing the cover plate into the the wrench-able protective cap using the Model W3 wrench. cup and turning the cover in the clockwise direction until it is tight Alternatively, Model RFC series sprinklers can be installed using against the ceiling. the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler.The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup,or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly.The Model W3 and FC wrenches are designed to be turned with a standard 1/2"square drive.Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads.Recommended installation torque for iron pipe fittings is 8 to 18 ft-lbs(11 to 24 N-m)for 1/2" thread sprinklers and 14 to 20 ft-lbs(19 to 27 N-m)for 3/4"thread sprinklers. Bulletin 006 Page 7 of 8 May 2022 Reliabld www.reliablesprinkler.com It 411111") • t Model FC Model W3 For use with Model RFC Series sprinklers For use with Model RFC Series sprinklers with without wrench-able cap installed wrench able cap installed Service/Spare Head Cabinet Wrench Listings and Approvals cULus Listed for Safety to ANSI/UL199 Model W8 High-strength plastic wrench Additional Listings for RFC30LL, RFC43LL, and RFC49LL: for limited(emergency) • cULus Certified for Health Effects to NSF/ANSI/CAN use with Model RFC Series 600 sprinklers without wrench-able • cULus Certified less than 0.25%Lead Content to NSF/ cap installed. Meets NFPA ANSI 372 Annex G. requirements for sprinkler • Australian WaterMark Certified, certificate number wrench on premises. 23347. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Maintenance Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are Model RFC series sprinklers should be inspected and the additionally covered by U.S. Patent No. 8,776,903. sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any Ordering Information sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare Specify the following when ordering. sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers Sprinkler should be maintained in the original cartons and packaging until • Model (RFC30, RFC30LL, RFC43, RFC43LL, used to minimize the potential for damage to sprinklers that would RFC49, RFC49LL, RFC58, RFC76) cause improper operation or non-operation. • Temperature Rating Cover Plate Guarantee • Model G5 • Temperature Rating For the Reliable Automatic Sprinkler Co., Inc.guarantee, terms, Spri•nkllee ishr Wrench and conditions,visit www.reliablesprinkler.com. • Model FC • Model W3 • Model W8(Limited use) N O f— Q) 0) T 0' T Z Bulletin 006 a May 2022 RIME Page 8 of 8 www.reliablesprink ler.corn See page 5 of 9 for the draft curtain criteria Bulletin 044 June 2020 ® Model KFR-CCS Combustible Concealed Space Sprinkler cULus Listed Features • cULus Listed for areas of coverage up to 256 square feet • Sprinkler may be installed on the same branch line that • ' � supplies sprinklers below ceiling • Nominal K-factor of 5.6(80 metric) • Fusible link operating element A.44 • • Quick response 212°F (100°C) fusible link operating element • Standard brass finish Product Description Reliable's Model KFR-CCS Combustible Concealed Space Sprinkler is a quick response, upright, special sprinkler designed to provide protection of specific light hazard combustible and noncombustible concealed spaces requiring sprinkler protection.The KFR-CCS sprinkler is specifically listed for the protection of shallow combustible concealed spaces described in NFPA 13. 431111111 1111110 The Model KFR-CCS Sprinkler utilizes a fast response solder-link fusible element that has demonstrated response times in laboratory tests which are five to ten times faster Model W2 Wrench than standard response sprinklers.This feature enables the sprinkler to apply water to a fire much faster than standard Note:A leak tight�/z" NPT(R1/2)sprinkler joint can be response sprinklers of the same temperature rating. obtained with an installation torque of approximately 8-18 ft-lbs(10.8-24.4 N-m). Do not tighten ssprinklers over these_ Application recommended limits Doing so may cause leakage and/or premature operation, The Model KFR-CCS sprinkler is specifically listed for use in horizontal combustible concealed spaces with a slope Maintenance not exceeding 2:12 with combustible wood truss,wood joist construction,or bar joist construction having a combustible Model KFR-CCS Sprinklers should be inspected and upper surface and where the depth of the space is less than maintained in accordance with the applicable version of NFPA 36" (914 mm)from deck to deck,from deck to ceiling, or with 25. Do not clean sprinklers with soap and water, ammonia or double wood joist construction with a maximum of 36" (914 any other cleaning fluids, Remove dust by using compressed mm) between the top of the bottom joist and the bottom of the air or by vacuuming, provided equipment does not touch the upper joist. NFPA 13 permits the use of the Model KFR-CCS sprinkler. Replace any sprinkler which has been painted (other sprinkler(a)where the space is less than 12"(305 mm)from than factory applied)or damaged in any way. A stock of spare deck to deck or deck to ceiling, and/or (b)where a portion of sprinklers should be maintained to allow quick replacement the protected space exceeds 36" (914 mm). of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and Installation packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Model KFR-CCS Sprinklers are to be installed in the upright position with their frames arms parallel to the pipe(Refer Guarantee to Figs. 4 through 9). When installing the Model KFR-CCS sprinkler use only the Reliable Model W2 installation wrench. For Reliable Automatic Sprinkler Co., Inc. guarantee, terms, Usage of any other type of installation wrench may damage and conditions, visit www.reliablesprinkler.com. the sprinkler and will immediately void the manufacture's warranty. Ordering Information Specify: Model KFR-CCS Sprinkler www.reliablesprinkler.com Model KFR-CCS Combustible Concealed Space Upright Sprinkler SIN RA4454 Finish Technical Specifications Standard Brass Style:Upright Threads: 112"NPT or ISO7-1R1/2 Temperature Ratings Nominal K-Factor:5.6(80 metric) 212°F(100°C) Max.Working Pressure: 175 psi(12 bar) .14 lit Sensitivity ,0 Material Specifications Fast Response Thermal Sensor:Nickel Alloy Sprinkler Frame:Brass Alloy Sprinkler Wrench Button:Copper Alloy Model W2 1 Sealing Assembly Nickel Alloy with PTFE Load Screw:Bronze Alloy Approvals Deflector:Bronze Alloy .;_,, cULus Listed Model KFR-CCS Components and Installation Dimensions Figure 1 1•21/32' DEFLECTOR (42 mm) I Ot u! ` COMPRESSION SCREW ', I- ` 11_ ,'11' 1,t `111 FUSIBLE LINK �' �i � '�I'�� It1'Indli SEALING ASSEMBLY \ iI :7:1III I( r ��I'i ill 211a^ I��.I F III 157 mm) ��Ily I�l :�®I111 !I III =- WRENCH FLATS FRAME -.-- "- 1 COMPONENTS DIMENSIONS Model KFR-CCS General Application Criteria Minimum Distance(Spacing) Between Sprinklers 6'(1.83m) Note:This minimum spacing does not apply to any additional sprinklers that are required for protection of CPVC piping that is offset over an obstruction (refer to figures 4 and 5). Maximum Distance(Spacing)Between Sprinklers 14'(4.27 m)for solid wood and composite wood joist construction. For wood truss or bar joist construction, 14' (4.27 m)for concealed spaces that are less than 18" (457 mm) in depth; 16' (4.88 m)for concealed spaces that are 18" (457 mm)or more in depth. Maximum Coverage Area Per Sprinkler 196 ft2(18.2 m2)for solid wood or composite wood joist construction. For wood truss or bar joist construction, 196 ft2(18.2 m2) for concealed spaces that are less than 18" (457 mm) in depth; 256 ft2(23.8 m2)for concealed spaces that are 18"(457 mm)or more in depth. Note;Sprinkler spacing,and therefore coverage area, is determined by the depth of the concealed space. When transitions occur in the concealed space,the sprinklers may immediately be spaced at the largest approved coverage area per the above listings for the concealed space depth (refer to Fig. 2). Obstruction Rules All obstruction criteria per the applicable version of the NFPA 13 apply unless modified by this bulletin (refer to Fig. 3). The KFR- CCS is classified as an Extended Coverage Upright Spray Sprinkler where the maximum coverage area per sprinkler exceeds 225 ft2(20.9 m2). The KFR-CCS is classified as a Standard Upright Spray Sprinkler where the maximum coverage area per sprinkler is 225 ft2(20.9 m2)or less. Bulletin 044 Page 2 of 9 June 2020 Reliabld www.reliablesprinkler.com Model KFR-CCS Sprinkler Spacing at Change in Concealed Space Depth Figure 2 KFR-CCS SPRINKLER UPPER DECK LESS THAN ? I — p A A I8 [452mm] '� _ri' _ [45/mm] OR GREATER SEE ND , r ------------------ ZCEILING 8'-0.MAX MAXIMUM SPACING MAXIMUM SPACING 14'X 14'[4.3 m X 4.3 m] —•-- 16'X 16.[4.9 m X 4.9 m] °'O6tlr' 196 SF[18.2 re] 256 SF[23.8 m'] Note I:For sloping concealed spaces,breok poinl between sprinkler spacings is the point where the depth of the space equals l8"[457 mm]. Bulletin 044 Page 3 of 9 June 2020 Reliable www.reliablesprinkler.com Model KFR-CCS Specific Application Obstruction Criteria Figure 3 DISTANCE FROM CENTERLINE MAXIMUM ALLOWABLE OF SPRINKLER TO SIDE OF DISTANCE OF DEFLECTOR OBSTRUCTION. ABOVE BOTTOM OF UPPER DECK OR BOTTOM OF 17' DIMENSION"A" OBSTRUCTION. DIMENSION"B" OBSTRUCTIONNONCOMBUSTIBLE INSULATION 2.0F a B• [<305mc1 19mm] 1- KFR-CCS 1210<18 SPRINKLER (305mm TO<46Tmm) 164 164 mm( 18'TO<24' 3.5' — "A" --_ 1451mm TO<6'0mm1 189mm1 24'TO<30' S.5' 1610mm TO<762mm1 1140mm] 30'TO<36' 1_y NOTE: 1762mmTo<914mm] Il91mm1 SPRINKLER DEFLECTOR MUST BEAT OR BELOW THE BOTTOM 36'TO<42• OF THE TOP CHORD OF THE TRUSS. 1914mm To<1067mml 1241r.m] 42'TO<48' 12' OTHER WEB MEMBERS AND GUSSETS SHALL NOT BE 11067mm TO<1219mm1 ]30.5mm) CONSIDERED OBSTRUCTIONS PROVIDED THE MINIMUM 4-V2" 49'TO<54' 14' LATERAL DISTANCE(FIG.4,6,8.8)REQUIRED BY THE SPECIFIC 11219mm TO<1322mm] [356mm] APPLICATION LISTING IS MAINTAINED. 54'TO<6O' 16.5' (13I2m TO<1524mm) 1419mm) UPPER DECK OBSTRUCTION KFR-CCS OBSTRUCTION ,,,,,,....re/i SPRINKLER KRLE SPRINKLER C [-v-17 LOWER DECK h--"A"-.. .^D" '~� _i_o ELEVATION VIEW PLAN VIEW A23C OR 3D(USE DIMENSION C OR D,WHICHEVER IS GREATER) MAXIMUM CLEAR DISTANCE REQUIRED IS 24 IN.(610 mm) MINIMUM HORIZONTAL DISTANCE VERTICAL DISTANCE DIMENSION'A" BELOW DEFLECTOR -"A" DIMENSION"B" UPPER DECK se 3- 15152mm) I76mml 1>152mm TO 229mm) [102mm1 KFR-CCS SPRINKLER >9'TO 12' 6' I>229rnm TO 305mm] [152rrm] OBSTRUCTION >12 TO l s' Cr I'305mm TO 361mm1 1203mm] LOWER DECK >151TO 18' 9.5' (>381mm TO 457mm1 [241mm] >18'TO 24' 12.5' )>457mm TO 610mm] 1318mm] >24'TO 30' 15 5' (>610mm TO762mm) 1394mm1 >30' 18' 1<782mm) (457mm] 044F003A Bulletin 044 Page 4 of 9 June 2020 Reliabl4 www.reliablesprinkler.com Model KFR-CCS Specific Application Criteria for CPVC Pipe Sprinkler Systems When used with CPVC piping,the Model KFR-CCS Sprinkler Minimum Distance Away From Face of Wood Truss or Top is specifically listed to provide protection of combustible con- Chord of Bar Joist cealed spaces where the construction methods consist of: 4.5 in. (114 mm) (Refer to Fig. 3) 1. Wood trusses or wood bar joist(Refer to Fig. 4) 2. Noncombustible insulation-filled solid wood or composite Deflector Position wood joists'(Refer to Fig. 5) At or below the bottom of the top chord; 1.5 in. (38 mm) minimum to 4 in. (102mm) maximum below upper deck(or 'Note: In order to be considered "noncombustible insula- insulation if present)for wood truss construction or wood bar tion-filled, solid wood or composite wood joists" construction, joist construction (Fig. 4). the insulation(including insulation provided with a combusti- ble vapor barrier), must completely fill the pockets between 1.5 in. (38 mm)minimum to 4 in. (102mm)maximum below the joists to the bottom of the joists. Insulation installed above bottom of insulation for noncombustible insulation-filled solid the elevation of Model KFR-CCS sprinklers in wood truss, solid or composite joist construction (Fig.5). wood joist or composite wood joist must be secured into place with metal wire netting. The metal wire netting is intended to HydraulicCeDesign Area hold the insulation in place should the insulation become wet to thel1,0 all ft2s 2 withinx the draft curtain area, up by the operation of Model KFR-CCS Sprinklers in the event of Note:Additionaldit (93 m2)nmaximum draft curtainafor area. a fire. sprinklers that are required protection of CPVC piping that is offset over an obstruction do not need to In order to use the CPVC pipe and fittings,the horizontal be included in the remote area. runs of pipe must be a maximum of 6 in. (152 mm)above the ceiling or noncombustible ceiling insulation, or 1/3 the depth Required Density of concealed space(as measured from the top surface of the 0.10 gem/ft2(4.08 Lpm/m2) ceiling to the bottom of the deck above),whichever is smaller (Refer to Figs. 4&5). Minimum Operating Pressure 7 psi (0.48 bar) The CPVC piping can be used to supply the Model KFR-CCS Sprinklers as well as sprinklers installed below the ceiling. Unless modified by this technical data sheet, all guidelines provided by the CPVC pipe and fitting manufacturer must be followed. When using 1 in. (DN25) or larger pipe, a hanger must be located at the truss nearest a sprig for purposes of restraint. If using 3/4 in. (DN19)piping, all sprigs over 12 in. (305 mm) must be laterally braced using methods described in the NFPA standards. Where the CPVC must be offset up and over an obstruction and the pipe exceeds the allowed horizontal positioning requirements specified above as well as shown in Figs. 4 and 5, additional Model KFR-CCS Sprinklers are to be installed to protect the CPVC products. A minimum lateral distance of 18 in. (457 mm)must be maintained between the CPVC pipe and heat pumps,fan motors,and heat lamps. Concealed Space Area The area of the concealed space is not limited; however,for both Figs.4 and Fig. - draft-curtains or full height walls must be rovided at 1,000 ft2: 93 m2 maximum areas (203 mm),whichev- er is greater,and be constructed using a material that will not allow heat to escape through or above the draft curtain. System Type Light hazard,wet pipe system. Bulletin 044 Page 5 of 9 June 2020 Reliably www.reliablesprinkler.com Model KFR-CCS CPVC Pipe Figure 4 CPVC PIPE CONSTRUCTION: WOOD TRUSS OR WOOD BAR JOIST TOP CHORD DEPTH 4' 4-I/2" [114mm]MINIMUM FROM (100 mm)OR LESS --'0.- -.--CENTERLINE OF SPRINKLER TO o«roN_w FACE OF WOOD TRUSS OR UPPER TOP CHORD OF BAR JOIST 4. DECK Nifx SEE NOTE 1 -- ' sx -\�- MAXIMUM AI r 6'[752mm] TI if II j SEE NOTE 2 r- ----f /1 lift I KFR-CCS SPRINKLERS TO BE I • I INSTALLED WITH FRAME ARMS I - I IN-LINE(PARALLEL)WITH PIPE. I OBSTRUCTION �I U�l vv�l ll� CEILING I V,,,,, -,,, i , „ A' - \ \lr —PIPE SHALL BE LOCATED A MAXIMUM OF 6"ABOVE THE TOP OF THE WHEN OFFSETTING CPVC PIPE OVER CEILING(OR INSULATION).OR A MAXIMUM OF ONE-THIRD(I/3)THE OBSTRUCTION,A KFR-CCS SPRINKLER MUST BE DEPTH OF THE CONCEALED SPACE ABOVE THE TOP OF THE CEILING, INSTALLED DIRECTLY ON THE PIPE OVER THE WHICHEVER IS SMALLER. OBSTRUCTION. Note 1: Deflector of or below bottom of top chard; 1-1/2"(38 ram)minimum to 4' (102 mm)maximum below bottom of roof deck or insulation. Note 2: Distance evaluated as port of cULus Listing: 12"to 36"(305 to 914 mm). NFPA 13 permits the installation of these sprinklers in combustible concealed spaces where (o) the distance from deck to deck or deck to ceiling is less then 12"(305 mm) and/or(b)a portion of the protected area exceeds a depth of 36" (914 mm). Model KFR-CCS CPVC Pipe Figure 5 CPVC PIPE CONSTRUCTION: NONCOMBUSTIBLE INSULATION-RILED SOLID WOOD OR COMPOSITE WOOD JOIST Dew w UPPER NONCOMBUSTIBLE SOLID WOOD COMPOSITE WOOD DECK INSULATION JOISTS JOISTS `"' cI MAXIMUM SEE NOTE 3 SEE NOTE 1 i 1` i i 6"[152mm] SEE NOTE 2 1-KFR-CCS SPRINKLERS TO BE III�I�.II� 1 INSTALLED WITH FRAME ARMS I LN-LANE(PARALLEL) WITH PIPE.J OBSTRUCTroN 144111 "I CEILING PIPE SHALL BE LOCATED A MAXIMUM OF 6"ABOVEJ WHEN OFFSETTING CPVC PIPE OVER THE TOP OE THE CEIUNG (OR INSULATON), OR A OBSTRUCTION,A KFR-CCS MAXIMUM OF ONE-THIRD(1/3)THE DEPTH OF SPRINKLER MUST BE INSTALLED THE CONCEALED SPACE ABOVE THE TOP OF THE DIRECTLY ON THE PIE OVER THE CEILING,WHICHEVER IS SMALLER. OBSTRUCTION. Note 1:Deflector distance below bottom of joist/insulation to be I-1/2"to 4(38 mm to 102 mm). Note 2:Distance evaluated as port of cULus Listing: 6"to 36"(152 to 914 mm). NFPA I3 permits the installation of these sprinklers in combustible concealed spaces where a portion of the protected area exceeds a depth or 36"(914 mm). Note 3.Maximum distance evaluated as port of cULus Listing: 60"(1524 ones). Bulletin 044 Re�iab�e Page 6 of 9 June 2020 www.reliablesprinkler.com Model KFR-CCS Specific Application Criteria for Steel Pipe Systems When used with steel piping, the Model KFR-CCS Sprinkler System Type is specifically listed to provide protection of combustible Light hazard, wet or dry pipe system. concealed areas where the construction methods consist of 1. Wood trusses or wood bar joists(Refer to Fig. 6) Deflector Position 2. Solid wood joist construction where the upper ceiling At or below the bottom of the top chord; 1.5 in. (38 mm) joists may have a maximum depth of 12 in. (305 mm). minimum to 4 in. (102mm)maximum below upper deck(or (Refer to Fig. 7). insulation if present)for wood truss construction or wood bar 3. Noncombustible insulation-filled, solid wood or composite joist construction (Fig. 6). wood joists*(Refer to Fig. 8) 1.5 in. (38 mm)minimum to 2 in. (51 mm)maximum below the 4. Obstructed wood trusses; top chord more than 4" deep bottom of the top chord for spaces constructed of obstructed (Refer to Fig. 9). wood trusses(Fig. 8). *Note: In order to be considered "noncombustible insulation- 1.5 in. (38 mm)minimum to 2 in. (51 mm) maximum below the filled, solid wood or composite wood joists" construction,the bottom of the upper joist for concealed spaces constructed of insulation(including insulation provided with a combustible exposed solid wood joists(Fig 7). vapor barrier), must completely fill the pockets between the joists to the bottom of the joists. Insulation installed above the 1.5 in. (38 mm) minimum to 4 in. (102mm)maximum below elevation of Model KFR-CCS sprinklers in wood truss, solid bottom of insulation for noncombustible insulation-filled solid wood joist or composite wood joist must be secured into place or composite joist construction (Fig. 9). with metal wire netting. The metal wire netting is intended to hold the insulation in place should the insulation become wet Minimum Distance Away From Face of Wood Truss or Top by the operation of Model KFR-CCS Sprinklers in the event of Chord of Bar Joist a fire. 4.5 in. (114 mm)(Refer to Fig. 4) Hydraulic Design Area Concealed Space Area For wood truss construction (Fig. 6), solid wood joist The area of the concealed space is not limited; however, construction (Fig. 7), or obstructed wood truss construction for wood truss construction or concealed spaces of (Fig. 8), calculate all sprinklers within the draft curtain area, noncombustible bar joist construction (Refer to Fig. 6)draft- up to the 1,000 ft2(93 m2)maximum draft curtain area for both curtains or full height walls must be provided at 1,000 ft2(93 wet and dry pipe systems. m2)areas. The draft curtain shall be at least 1/3 the depth of the concealed space or 8 in. (203 mm),whichever is greater, For noncombustible insulation-filled solid wood joist or and be constructed using a material that will not allow heat to composite wood joist construction (Fig.9)where draft curtains escape through or above the draft curtain. are not required, calculate per the requirements of NFPA 13. For solid wood joist construction (Refer to Fig. 7)and obstructed wood truss construction (Refer to Fig. 8), blocking Required Density must be provided in each joist or top chord channel at 0.10 gpm/ft2(4.08 Lpm/m2) maximum 32 ft. (9.75 m) intervals.This blocking shall be installed to the full depth of the joist or top chord and be Minimum Operating Pressure installed so as to not allow heat to escape through or above 7 psi (0.48 bar) the blocking. The blocking must be constructed using a noncombustible material or be of the same material as the joist or truss member. Draft curtains must be protrude below the joist a minimum of 6 in. (152 mm)or 1/3 the space, whichever is greatest and run parallel with the joist spaced at 31 ft. (9.45 m)width maximum to limit the area to a maximum of 1,000 ft2(93 m2).The draft curtain may be constructed of lA in. (6.4 m)plywood to prevent heat from escaping beyond the area. For noncombustible insulation-filled, solid wood joist or composite wood joist construction (Refer to Fig. 9),the requirement for draft curtains or blocking does not apply. Bulletin 044 Page 7 of 9 June 2020 Reliable www.reliablesprinkler.com Model KFR-GCS Steel Pipe Figure 6 STEEL PIPE CONSTRUCTION: WOOD TRUSS OR WOOD BAR JOIST (TOP CHORD 4"OR LESS IN DEPTH) a<avoaa_as FROM FACE OF WOOD TRUSS OR TOP WOOD TRUSS —w- OF CHORD OF BAR JOIST OR BAR JOIST 4.5'[114mm] MINIMUM DISTANCE UPPER DECK�' SEE NOTE 1 N. P ,fl--G �\ Ir KFR-CCS SPRINKLERS TO BE ' INSTALLED WITH FRAME ARMS 1 SEE NOTE 2 LN-UNE (PARALLEL)WITH PIPE. 1 VI i LOCATION OF STEEL PIPE IN CONCEALED SPACE IS NOT RESTRICTED CEILING N. Note 1: Deflector at or below the bottom of the top chord; 1-1/2' (38 mm) to 4'(102 arm) below bottom of roof deck or insulation. Note 2: Distance evaluated as part of cULus Listing: 12"to 36"(305 to 914 mm). NFPA 13 permits the installation of these sprinklers in combustible concealed spaces where (a) the distance from deck to deck or deck to ceiling is less than 12'(305 mm) and/or(b) a portion of the protected area exceeds a depth of 36" (914 mm). Model KFR-CCS Steel Pipe Figure 7 STEEL PIPE CONSTRUCTION: SOLID WOOD JOIST 044F 4 o9 UPPER 2X FLOOR JOISTS DECK SOLID WOOD 16'[406mm] ON CENTER Ns N \ \ z'MAXIMUM [305mm] N. N. N N SEE NOTE 2 KFR-CCS ' ` \ FOR MAXIMUM f ee N. rSPRINKLER DISTANCE SEE NOTE 1 L_ Ai MINIMUM DISTANCE FOR MINIMUM T -1 1.5"[3Bmm] AND MAXIMUM ALL SPRINKLERS TO BE 1 MAXIMUM DISTANCE INSTALLED WITH DISTANCE 2"[5lmm] 1 I FRAME ARMS IN-UNE WITH THE I — RUN OF THE PIPE. (PARALLEL) I _ J .11 \ V� V�\ CEILING -NNFRAMING CEILING Note 1: Minimum to Maximum Distance evaluated as pad of cULus Listing: 6" to 36"(152 to 914 mm). NFPA 13 also permits the installation of these sprinklers in combustible concealed spaces where (1) the distance from deck to deck or deck to ceiling is less than 12'(305 mm) or (2) a portion of the protected area exceeds a depth of 36"(914 mm). Note 2: Maximum Distance evaluated as part of cULus Listing: 54" (1372 mm). NEPA 13 also permits the installation of these sprinklers in combustible concealed spaces where(1) the distance from deck to deck or deck to ceiling is less than 12" (305 mm) or(2) a portion of the protected area exceeds a depth of 36'(914 mm). Bulletin 044 Page 8 of 9 June 2020 Rellabl� www.reliablesprinkler.com Model KFR-CCS Steel Pipe Figure 8 STEEL P PE CONSTRUCTION: OBSTRUCTED WOOD TRUSS OR BAR JOIST (TOP CHORD MORE THAN 4 IN, DEPTH) 0441G04 09 WOOD TRUSS OR BAR JOIST UPPER DECK 111111 11 ,,, 1arimir I lit SEE NOTE 3 I � I • SEE NOTE 1 SEE NOTE 2 rKFR-CCS SPRINKLERS TO BE LOCATION OF INSTALLED WITH FRAME ARMS PIPE IN CONCIN-LINE (PARALLEL) WITH PIPE.JSPACE IS NO ` RESTRICTED -I■I ENEIR 1341 b al I I I Nili CEILING Note 1: Deflector distance below bottom of joist to be 1-1/2" to 2" (38 mm to 51 mm). Note 2: Distance evaluated as part of cULus Listing: 6" to 36" (152 to 914 mm). NFPA 13 also permits the installation of these sprinklers in combustible concealed spaces where o portion of the protected ores exceeds a depth of 36" (914 mm). Note 3: Maximum distance evaluated as part of cULus Listing: 60" (1524 mm). Model KFR-CCS Steel Pipe Figure 9 STEEL PIPE CONSTRUCTION: NONCOMBUSTIBLE INSULATION—FILLED SOLID WOOD OR COMPOSITE WOOD JOIST 0HfGa4_a9 NONCOMBUSTIBLE SOLD WOOD COMPOSITE WOOD UPPER INSULATION JOISTS JOISTS DECK \ . . \ / \ \ \ SEE NOTE 3 1 t i b } � �, 1SEE NOTE 2 LEE NOTE 1 1—KFR-CCS SPRINKLERS TO BE, LOCATION OF STEEL I INSTALLED WITH FRAME ARMSI PIPE IN CONCEALED LIN—UNE (PARALLEL) WITH PIPE. I—I RESTRICTED NOT '1I n a \7 7 7 `� �V} I//f'////Il.1l//I/I/L///II/Ilj///I///JJ////// �J/!// CEILING Os V Note 1: Deflector distance below bottom of joist/insulation to be 1-1/2" l0 4"(38 mm to 102 m). o m n Note 2: Distance evaluated as part of cULus Listing: 6" to 36"(152 to 914 mm). NFPA 13 permits the installation of these 0) sprinklers in combustible conceoled spaces Where a portion of the protected ores exceeds a depth of 36" (914 mm). 01 CA Note 3: Maximum distance evoluoted as port of cULus Listing:60" (1524 men). 0) z a` Bulletin 044 Page 9 of 9 June 2020 Reliabl4 www.reliablesprinkler.com Bulletin 056 July 2022 .. Fietmid Models DD56-6, DD56-27, DD8O-6, DD8O-27, I DS56, GP56, AH42, &AH56 Sprinklers Specific Application Sprinklers for Attic Spaces cULus Listed Features tI7 ^^r,. • Coverage for DD80 spans up to 70 ft(21 m)with one row of ( " {^ • sprinklers I s • Coverage for DD80 spans up to 100 ft(30.5 m)with three rows of sprinklers t '" • All models use a 212°F(100°C)temperature rated fusible- t i link operating element .a, • 150 square foot per sprinkler protection using GP56 and AH Series sprinklers Model DD56 (Model DD80 similar) Model DS56 Product Description Reliable Attic Sprinklers are cULus Listed Specific Application sprinklers.The sprinklers are available for protection of combustible and non-combustible light hazard concealed /` ii spaces with roof/ceiling slopes of 4:12 to 8:12. Reliable . ,C d y Attic Sprinklers are upright sprinklers listed for use on `' wet-pipe or dry-pipe sprinkler systems.All Reliable Attic )i r sprinklers use a 212°F(100°C)temperature rated fusible- "` +'` link operating element that is Listed for installation where the maximum ceiling temperature is up to 150°F(66°C).Table A Model GP56 Model AH56 provides a summary of available Reliable Attic sprinklers. (Model AH42 similar) Application some cases, a combination of layouts may be required. The Authority Having Jurisdiction should be consulted for situations Reliable Attic Sprinklers are listed for installation in accordance that are not specifically addressed within this bulletin. with this bulletin and NFPA 13, 'Standard for the Installation of Fire Sprinklers." The sprinklers are classified as Special Special Note Regarding Insulation Sprinklers by NFPA 13,and are intended for installation within combustible or noncombustible roof structures, including those Noncombustible insulation, properly secured with wire with wooden trusses. Coverage area, spacing requirements, netting to prevent sagging onto sprinklers may be used and design flow and pressure for each sprinkler are provided at the roof deck. Spray foam has not been evaluated for in tables B-I on the individual sprinkler data sheets in this use with attic sprinklers. Use of spray foam insulation bulletin. Example sprinkler layouts and hydraulic design criteria with attic sprinklers should be evaluated on a case by are provided in Figures 9 through 25. Please note that the case basis with the Authority Having Jurisdiction. example sprinkler layouts are intended as design aids only, and do not necessarily reflect all possible construction methods. In Attic Sprinkler Summary Table A Sprinkler K-Factor Thread Size Max.Coverage Area Sprinkler Model gpm/psi72 NPT or (Measured on Floor) Roof Slope Design Criteria Identification (L/min/bar'2) 1507-1 ft x ft(m x m) Number(SIN) DD56-6 5.6(80) '/2 6 x 40(1.8 x 12) 4:12 to<6:12 Table B RA5624 DD56-27 5.6(80) 1/ 6 x 40(1.8 x 12) 6:12 to 8:12 Table C RA5694 DD80-6 8.0 3/4 6 x 66 or 5 x 70 115 ( ) (1.8x20or1.5x21) 4:12 to<6:12 Table D RA5622 DD80-27 8.0(115) 3/4 6 x 66 or 5 x 70 6:12 to 8:12 Table E RA5692 (1.8x20or1.5x21) DS56 5.6(80) '/: 6 x 40(1.8 x 12) 4:12 to 8:12 Table F RA5625 GP56 5.6(80) '/2 10 x 15(3.0 x 4.6) 4:12 to 8:12 Table G RA5695 AH42 4.2(60) '/2 10 x 15 (3.0 x 4.6) 4:12 to 8:12 Table H RA5623 AH56 5.6(80) '/2 10 x 15(3.0 x 4.6) 4:12 to 8:12 Table I RA5626 www.reliablesprin kler.com Model DD56-6 Specific Application Sprinkler SIN RA5624 Technical Specifications Listings and Approvals Style:Upright cULus Listed Orientation:Deflector horizontal Threads:1/2"NPT or ISO 7-1 R1/2 Hazard Classification Nominal K-Factor:5.6(80 metric) Light Hazard Max.Working Pressure: 175 psi(12 bar) System Types Sprinkler Temperature Rating:212°F(100°C) Wet-pipe with steel or Listed CPVC pipe Sensitivity:Quick-response Dry-pipe with steel pipe Hydraulic Design Criteria (See Table B and Figures 9-29) Installation Criteria .z,€- Sprinkler Spacing :.,„,„ I " Finish Minimum 4 ft(1.2 m),maximum 6 ft(1.8m) S ° Brass between sprinklers along ridge z ' s Minimum 26 ft(7.9 m)down the roof slope Sprinkler Wrench a".e Model W2 toward cave to nearest sprinkler, i, measured parallel to the roof deck Material Specifications Horizontal Distance from Face of Truss 3 + .S. Thermal Sensor:Nickel Alloy Solder Link Min:6 inches(150 mm) " 1 Levers:Stainless Steel Sprinkler Frame:Brass Alloy Vertical Distance of Deflector Above Scissor Button:Copper Alloy Truss : Button Clip:Stainless Steel Min: 18 inches(450 mm) Sealing Assembly:Nickel Alloy with PTFE Horizontal Distance from Center-line of Ridge Load Screw:Bronze Alloy Max:6 inches(150 mm) Deflector:Bronze Alloy Vertical Distance of Top of Deflector Below Peak,Ridge,or Deck Min: 17 inches(430 mm) Max:21 inches(530 mm) Model DD56-6 Sprinkler Components and Dimensions Figure 1 1-3/32" 2-5/16" 1 (28 mm) [..--- (59 mm) — — oat Ems _ Deflector I—) I I I� ,I r I I AO066 aR Fusible Link — o 2-1/2" YEAR Wrench Flat :w (64 mm) ( 1iE ASC® RASC® ��� 21z'F/100'c --' RA Sal v Model DD56-6 Minimum Required Flow and Residual Pressure Table B Ceiling Slope Max.Coverage Area Flow Pressure 1 ' ft x ft(m x m) gpm(I/min) psi(bar) 4:12 to less than 6:1201 6 x 4012)(1.8 x 12) 25 (95) 19.9(1.37) Notes: 1. For the singular instance of an asymmetrical pitch of 4:12 to less than 6:12 on one side of a ridge and a pitch of 6:12 on the opposite side of the ridge, use of the Model DD56-6 is acceptable. For all other pitches of 6:12 up to 8:12, refer to the Model DD56-27. 2. Long dimension of coverage area to be along the roof slope parallel to trusses. Length of coverage area is split equally to each side of the sprinkler at the ridge. Coverage area is measured parallel to the floor. Bulletin 056 Page 2 of 27 July 2022 Reliable www.reliablesprinkler.com Model DD56-27 Specific Application Sprinkler SIN RA5694 Technical Specifications Listings and Approvals Style:Upright cULus Listed Orientation:Deflector horizontal Threads:1/2"NPT or ISO 7-1 R1/2 Hazard Classification Nominal K-Factor:5.6(80 metric) Light Hazard Max.Working Pressure:175 psi(12 bar) System Types Sprinkler Temperature Rating:212°F(100°C) Wet-pipe with steel or Listed CPVC pipe Sensitivity:Quick-response Dry-pipe with steel pipe Hydraulic Design Criteria g (See Table C and Figures 9-29) Installation Criteria 4„ Sprinkler Spacing Finish Minimum 4 ft(1.2 m),maximum 6 ft(1.8m) Brass between sprinklers along ridge r ., Minimum 26 ft(7.9 m)down the roof slope 4,Sprinkler Wrench Model W2 toward eave to nearest sprinkler, , measured parallel to the roof deck Material Specifications Horizontal Distance from Face of Truss ;. Thermal Sensor:Nickel Alloy Solder Link Min:6 inches(150 mm) Levers:Stainless Steel Sprinkler Frame:Brass Alloy Vertical Distance of Deflector Above Scissor Button:Copper Alloy Truss Button Clip:Stainless Steel Min: 18 inches(450 mm) Sealing Assembly:Nickel Alloy with PTFE Horizontal Distance from Center-line of Ridge Load Screw:Bronze Alloy Max:6 inches(150 mm) Deflector:Bronze Alloy Vertical Distance of Top of Deflector Below Peak,Ridge,or Deck Min: 17 inches(430 mm) Max:21 inches(530 mm) Model DD56-27 Sprinkler Components and Dimensions Figure 2 1-3/32" 2-9/32" 1 (28 mm) (58 mm) — r*--- -__-;_--... yam ■ Deflector 11- 11 Ir a * I I n OR Fusible Link = i �" �1 1111 2-1/2" cad YEAR Wrench Flat !� (64 mm) ! ! ''"� d B ` i'.:ASCO RASCC ` 212'F/100'C Threads - — v ME694 • Model DD56-27 Minimum Required Flow and Residual Pressure Table C i i^ Max.Coverage Area Flow Pressure Ceiling Slope �` ft x ft(m x m) gpm(I/min) psi(bar) tiff: 6.12 to 8:12m 6 x 40*(1.8 x 12) 25 (95) 19.9 (1.37) *Long dimension of coverage area to be along the roof slope parallel to trusses. Length of coverage area is split equally to each side of the sprinkler at the ridge. Coverage area is measured parallel to the floor. Bulletin 056 Page 3 of 27 July 2022 e www.reliablesprinkler.com Model DD80-6 Specific Application Sprinkler SIN RA5622 Technical Specifications Listings and Approvals Style:Upright cULus Listed Orientation:Deflector horizontal Threads:3/4"NPT or ISO 7-1 R3/4 Hazard Classification Nominal K-Factor:8.0(115 metric) Light Hazard Max.Working Pressure: 175 psi(12 bar) System Types Sprinkler Temperature Rating:212°F(100°C) Wet-pipe with steel or Listed CPVC pipe Sensitivity:Quick-response Dry-pipe with steel pipe Hydraulic Design Criteria Installation Criteria ` '' " See Table D and Figures 9-29) s ( g Sprinkler 6 jyi Finish Minimum 4 ft(1.2 m),maximum 6 ft(1.8m) Brass between sprinklers along ridge Minimum 26 ft(7.9 m)down the roof slope - Sprinkler Wrench toward eave to nearest sprinkler, .-v I Model W2 measured parallel to the roof deck , , Material Specifications Horizontal Distance from Face of Truss Thermal Sensor Nickel Alloy Solder Link Min:6 inches(150 mm) fri Levers:Stainless Steel , , Sprinkler Frame:Brass Alloy Vertical Distance of Deflector Above Scissor Button:Copper Alloy Truss Button Clip:Stainless Steel Min: 18 inches(450 mm) Sealing Assembly:Nickel Alloy with PTFE Horizontal Distance from Center-line of Ridge Load Screw:Bronze Alloy Max:6 inches(150 mm) Deflector:Bronze Alloy Vertical Distance of Top of Deflector Below Peak,Ridge,or Deck Min: 17 inches(430 mm) Max:21 inches(530 mm) Model DD80-6 Sprinkler Components and Dimensions Figure 3 1-3/32" 2-5/16" 1 (28 mm) r _ (59 mm) Minn I•�■ Deflector Iileil kg,' I II I '°c" °R Fusible Link �'�" ®r-�111 2-7/8" c 5S YEAR Wrench Flat i (73 mm) tiii Ahri, 0 3 ASC® RASC® 212'F/100'C Threads �� �� �■ — �-= 6 Model DD80-6 Minimum Required Flow and Residual Pressure Table D Ceiling Slope Max.Coverage Area Flow Pressure ft x ft(m x m) gpm(I/min) psi(bar) 6 x 40 (1.8 x 12)(2) 25(95) 9.8 (0.68) 6 x 63(1.8 x 19)(2) 38(144) 22.6 (1.56) 4:12 to less than 6:12 6 x 66(1.8 x 20)(2) 40(151) 25(1.72) 5x70(1.5x21)(2) 38(144) 22.6(1.56) Notes: 1. For the singular instance of an asymmetrical pitch of 4:12 to less than 6:12 on one side of a ridge and a pitch of 6:12 on the opposite side of the ridge, use of the Model DD80-6 is acceptable. For all other pitches of 6:12 up to 8:12, refer to the Model DD80-27. 2. Long dimension of coverage area to be along the roof slope parallel to trusses. Length of coverage area is split equally to each side of the sprinkler at the ridge. Coverage area is measured parallel to the floor. Bulletin 056 - Page 4 of 27 July 2022 el abI www.reliablesprinkler.com Model DD80-27 Specific Application Sprinkler SIN RA5692 Technical Specifications Listings and Approvals Style:Upright cULus Listed ,ya Orientation:Deflector horizontal Threads:3/4"NPT or ISO 7-1 R3/4 Hazard Classification '1'''''''';:-. :i Light Hazard K-Factor:8.0(115 metric) xA t. Max.Working Pressure:175 psi(12 bar) System Types t , Sprinkler Temperature Rating:212°F(100°C) Wet-pipe with steel or Listed CPVC pipe a Sensitivity:Quick-response Dry-pipe with steel pipe Hydraulic Design Criteria Installation Criteria d _.., (See Table E and Figures 9-29) Sprinkler Spacing : Finish Minimum 4 ft(1.2 m),maximum 6 ft(1.8m) $ Brass between sprinklers along ridge Minimum 26 ft(7.9 m)down the roof slope Sprinkler Wrench toward eave to nearest sprinkler, Model W2 measured parallel to the roof deck Material Specifications Horizontal Distance from Face of Truss Thermal Sensor:Nickel Alloy Solder Link Min:6 inches(150 mm) Levers:Stainless Steel Vertical Distance of Deflector Above Scissor Sprinkler Frame:Brass Alloy Truss Button:Copper Alloy Min: 18 inches(450 mm) Button Clip:Stainless Steel Sealing Assembly:Nickel Alloy with PTFE Horizontal Distance from Center-line of Ridge Load Screw:Bronze Alloy Max:6 inches(150 mm) Deflector:Bronze Alloy Vertical Distance of Top of Deflector Below Peak,Ridge,or Deck Min: 17 inches(430 mm) Max:21 inches(530 mm) Model DD80-27 Sprinkler Components and Dimensions Figure 4 1-3/32" 2-9/32" (28 mm} (58 mm) Nam■ ■_■ . I>• _ 1 Deflector II i E7i\l 1 -\� i ikm- A aR Fusible Link i; 1 1i1l11" 2-7/8 n c YEAR Wrench Flat e (73 mm) Ua` r. iT , 9 r ASCO IRASC® zu F i xm•c Threads �. v F. zz• - Model DD80-27 Minimum Required Flow and Residual Pressure Table E Ceiling Slope Max.Coverage Area Flow Pressure ft x ft(m x m) gpm(I/min) psi(bar) 6 x 40* (1.8 x 12) 28(106) 12.3 (0.85) 6:12 to 8:12 6 x 63*(1.8 x 19) 38(144) 22.6 (1.56) 6 x 66*(1.8 x 20) 40(151) 25(1.72) 5 x 70*(1.5 x 21) 38(144) 22.6(1.56) *Long dimension of coverage area to be along the roof slope parallel to trusses. Length of coverage area is split equally to each side of the sprinkler at the ridge. Coverage area is measured parallel to the floor. Bulletin 056 Page 5 of 27 July 2022 Reliable www.reliablesprinkler.com Model DS56 Specific Application Sprinkler SIN RA5625 Technical Specifications Listings and Approvals Style:Upright cULus Listed Orientation:Frame arms perpendicular to roof deck Hazard Classification Threads:1/2"NPT or ISO 7-1 R1/2 Light Hazard Nominal K-Factor:5.6(80 metric) System Types Max.Working Pressure:175 psi(12 bar) Wet-pipe with steel or Listed CPVC pipe Sprinkler Temperature Rating:212°F(100°C) Dry-pipe with steel pipe Sensitivity:Quick-response Installation Criteria Hydraulic Design Criteria Sprinkler Spacing �. (See Table F and Figures 9-29) Minimum 4 ft(1.2 m),maximum 6 ft(1.8m) between sprinklers along ridge Finish Minimum 26 ft(7.9 m)down the roof slope Brass toward eave to nearest sprinkler, measured parallel to the roof deck ` 1 Sprinkler Wrench Model DS56 Horizontal Distance from Face of Truss Min:6 inches(150 mm) Material Specifications Thermal Sensor:Nickel Alloy Solder Horizontal Distance from Draft Curtain or Wall(') 1t Link Min:30 inches(762 mm) f;, Levers:Brass Alloy Max:42 inches(1067 mm) Frame Body:Brass Alloy Vertical Distance of Top of Deflector Above + , Frame Arms:Brass Alloy Bottom of Draft Curtain ='`-' Yoke:Copper Alloy Min:8 inches(200 mm) Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Vertical Distance of Deflector Above Scissor Deflector:Bronze Alloy Truss Min: 18 inches(450 mm) Distance from Top of Deflector to Roof Deck (measured perpendicular to roof deck) Min:9 inches(230 mm) Max: 13 inches(330 mm) li)Model DS56 sprinklers may be installed back-to-back on opposite sides of a ridge where a draft curtain is installed to separate the back- to-back rows of sprinklers. Model DS56 Sprinkler Components and Dimensions Figure 5 1-9/16" _ 1-11/16" • (40 mm) (43 mm) Deflector ,, st /, •, ISIIIIII RASCO MI) .( M /4 Fusible Link Q=o. Allii=r 2-13/16" wr ~ •�` I DS56 a '� 1 r 2 A562 Y MN RA5625 Wrench Flat n (71 mm) � YEAR RASCO Threads ---..` Model DS56 Minimum Required Flow and Residual Pressure Table F Ceiling Slope Max.Coverage Area Flow Pressure ,, ft x ft(m x m) gpm(I/min) wit, psi(bar) 6x30"(1.8x9.1) 23(87) 16.9(1,17) 4:12 to 8:12 6 x 40*(1.8 x 12) 35(132) 39.1 (2.70) *Long dimension of coverage area to be along the roof slope parallel to trusses. Length of coverage area is from the draft curtain or wall behind the sprinkler toward the eave. Coverage area is measured parallel to the floor. Bulletin 056 Page 6 of 27 July 2022 rabR www.reliablesprinkler.com Model GP56 Specific Application Sprinkler SIN RA5695 Technical Specifications Listings and Approvals Style:Upright cULus Listed Orientation:Top of deflector parallel to roof deck Threads:1/2"NPT or ISO 7-1 R1/2 Hazard Classification Nominal K-Factor:5.6(80 metric) Light Hazard Max.Working Pressure:175 psi(12 bar) System Types Sprinkler Temperature Rating:212°F(100°C) Wet-pipe with steel or Listed CPVC pipe Sensitivity:Quick-response Dry-pipe with steel pipe f [ • s i� Hydraulic Design Criteria Installation Criteria =- (See Table G and Figure 9-29) Sprinkler Spacing Finish Minimum 6 ft(1.8 m),maximum 10 ft(3.0 m) Brass between sprinklers across roof slope. a Minimum 6 ft(1.8 m)up roof slope to 4 Sprinkler Wrench nearest sprinkler,minimum 10 ft(3.0 ; l!�_ Model W2 m)down slope to nearest sprinkler, t:�• {„' Material S pecifications measured parallel to roof deck. u r Thermal Sensor:Nickel Alloy Solder Link Distance from Top of Deflector to Roof Deck Levers:Stainless Steel (measured perpendicular to roof deck) Sprinkler Frame:Brass Alloy Min:9 inches(230 mm) Button:Copper Alloy Max:13 inches(330 mm) Button Clip:Stainless Steel Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Deflector:Bronze Alloy Model GP56 Sprinkler Components and Dimensions Figure 6 1-7/8" 1-1/4" (48 mm) — (32 mm) '— Deflector NMI lUII I• Fusible Link 6,111 °A '7 ..YEAW Wrench Flat !.. (64 mm) 01!14 C'`' _ter_ •� c®w RA60105 ` RASCO RASCO % 20 Threads Model GP56 Minimum Required Flow and Residual Pressure Table G Max.Coverage Area Flow Pressure Ceiling Slope ft x ft gpm psi (m x m) (I/min) (bar) 4:12to8:12 (3.0x4.6) (64) 92 (0.63) *Long dimension of coverage area to be along the roof slope parallel to trusses. Coverage is 3 ft. (0.9m)toward the peak and 12 ft. (3.7m) toward the eave from the sprinkler. Coverage area to be measured parallel to the floor. Bulletin 056 Page 7 of 27 July 2022 ea■ ib�ae www.reliablesprinkler.com Model AH42 Specific Application Sprinkler SIN RA5623 Technical Specifications Listings and Approvals Style:Upright cULus Listedw Orientation:Top of deflector parallel to roof deck Threads: 1/2"NPT or ISO 7-1R1/2 Hazard Classification Nominal K-Factor:4.2(60 metric) Light Hazard Max.Working Pressure:175 psi(12 bar) System Types Sprinkler Temperature Rating:212°F(100°C) Wet-pipe with steel or Listed CPVC pipe Sensitivity:Quick-response Hydraulic Design Criteria Dry-pipe with steel pipe�2� (See Table H) Installation Criteria - ,a Sprinkler Spacing Finish Minimum 5 ft(1.5 m),maximum 10 ft(3.0 m) Brass between sprinklers across roof slope. . Sprinkler Wrench Minimum 12 ft(3.7 m)down slope to nearest n Model W2 sprinkler,measured parallel to roof deck. Note:A minimum 2 ft(0.61 m)lateral offset Material Specifications is required between AH sprinklers when Thermal Sensor:Nickel Alloy Solder Link viewed looking up the roof slope. Levers:Stainless Steel Sprinkler Frame:Brass Alloy Distance from Top of Deflector to Button:Copper Alloy Bottom of Truss Tap Chord(measured ;,m Button Clip:Stainless Steel perpendicular to roof deck) Sealing Assembly:Nickel Alloy with PTFE Min: 1 inches(25 mm) Load Screw:Bronze Alloy Max:3 inches(76 mm) Deflector:CHROME PLATED Bronze Alloy Frame Arm Orientation Frame arms are to be oriented parallel to the eave at the bottom of the protected space. Note: 1. Listed for the protection of sloped combustible and noncombustible concealed spaces, including hip roofs with traditionally framed or step down truss construction. 2. NFPA13 requires the use of corrosion resistant or internally galvanized steel piping when using sprinklers with a K-Factor of 4.2. Model AH42 Sprinkler Components and Dimensions Figure 7 1-5/8° (41 mm) Deflector ram: 461 IIIIVZ ,• \ ■ u �ssFusible Link /�/� "_" ��>]� 1 11• `� --- `'wII. , Wrench Flat Ili �!i Till 5 5/16' ..7 �� 411 II, III (59 mm) '� o ij f�i III.. <,,....-?„7 Threads AH42 DEFLECTOR IS CHROME PLATED Model AH42 Minimum Required Flow and Residual Pressure Table H Ceiling Slope Max.Coverage Area Flow Pressure ft x ft(m x m) gpm(I/min) psi (bar) 4:12 to 8:12 10 x 15* (3.O x 4.6) 15 (57) 12.8(0.88) *Long dimension of coverage area to be along the roof slope. Coverage is 6'-0"(1.8m)toward the peak and 9'-0"(2.7m)toward the eave from the sprinkler. Coverage area to be measured parallel to the floor. Note:The first row of AH sprinklers may be a maximum of 9'-0"from the eave; however,the first row must always be on the eave side of the girder truss(see Figures 24 and 25). Bulletin 056 Page 8 of 27 July 2022 Rellablg www.reliablesprinkler.com Model AH56 Specific Application Sprinkler SIN RA5626 Technical Specifications Listings and Approvals Style:Upright cULus Listed° Orientation:Top of deflector parallel to roof deck Hazard Classification Threads:1/2"NPT or ISO 7-1 R1/2 Li Nominal K-Factor:5.6(80 metric) ght Hazard Max.Working Pressure:175 psi(12 bar) System Types Sprinkler Temperature Rating:212°F(100°C) Wet-pipe with steel or Listed CPVC pipe Sensitivity:Quick-response Dry-pipe with steel pipe Hydraulic Design Criteria , ir (See Table I) Installation Criteria Sprinkler Spacing Finish Minimum 6 ft(1.8 m),maximum 10 ft(3.0 m) Brass between sprinklers across roof slope. 111 Sprinkler Wrench Minimum 12 ft(3.7 m)down slope to nearest Model W2 sprinkler,measured parallel to roof deck. Note:A minimum 2 ft(0.61 m)lateral offset } Material Specifications is required between AH sprinklers when Thermal Sensor:Nickel Alloy Solder Link viewed looking up the roof slope. Levers:Stainless Steel Sprinkler Frame:Brass Alloy Distance from Top of Deflector to Button:Copper Alloy Bottom of Truss Top Chord(measured Button Clip:Stainless Steel perpendicular to roof deck) Sealing Assembly:Nickel Alloy with PTFE Min: 1 inches(25 mm) Load Screw:Bronze Alloy Max:3 inches(76 mm) Deflector:Bronze Alloy Frame Arm Orientation Frame arms are to be oriented parallel to the eave at the bottom of the protected space. *Note:Listed for the protection of sloped combustible and noncombustible concealed spaces,including hip roofs with traditionally framed or step down truss construction. Model AH56 Sprinkler Components and Dimensions Figure 8 1-5/8' . (41 mm) Deflector AUK� SEMI Fusible Link i•OatW" 'i111 s I Rqs co Wrench Flat III �_:1_Ili (59 mm) I tl ��- �11114Z`>illIIP a 199� Threads imi "—` Model AH56 Minimum Required Flow and Residual Pressure Table Ceiling Slope Max.Coverage Area immi Flow Pressure ft x ft(m x m) pm(I/min) psi(bar) 4:12 to 8:12 10 x 15` (3.0 x 4.6) 15(57) 7.2(0.50) *Long dimension of coverage area to be along the roof slope. Coverage is 6'-0" (1.8m)toward the peak and 9'-0"(2.7m)toward the eave from the sprinkler. Coverage area to be measured parallel to the floor. Note:The first row of AH sprinklers may be a maximum of 9'-0"from the eave: however,the first row must always be on the eave side of the girder truss(see Figures 24 and 25). Bulletin 056 Page 9 of 27 July 2022 a www.reliablesprinkler.com Model DD Series Sprinkler-Example Layout(Not to Scale) Figure 9 Eav: - Model DD Serie Sprinkler(Typ.) E Eav- —.. Calculation Requirements: Wet System-Most demanding five(5)DD Series Sprinklers Dry System-Most demanding seven(7)DD Series Sprinklers Model DS56 Sprinkler-Example Layout(Not to Scale) Figure 10 Eav- Model DSS. Sprinkler(Typ.) Es3 t I' Q m it t ® ® e 1- t aitlE P v P e erall Curt*or W: Ea Calculation Requirements: Wet System-Most demanding five(5)DS56 Sprinklers Dry System-Most demanding nine 19)DS56 Sprinklers Bulletin 056 Page 10 of 27 July 2022 a Ia61 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Model DS56 Sprinklers Beyond Obstruction Example Layout(Not to Scale) Figure 11 Model DD Series Sprinkler(Typ.) 7 - 77 _ Pods — M It M -8I bsfruction(not necessarily full length of space) Model DS56 Sprinkler to protect- ny rk y y 1 T. 8 g B M y y behind obstruction(Required - - -- _ -- when coverage area exceeds 15') Calculation Requirements: Wet System-Most demanding live(5)DO Series Sprinklers and two(2)DS56 Sprinklers Dry System-Most demanding seven(7)DD Series Sprinklers and two(2)DS56 Sprinklers Model DS56 Sprinklers at Ridge with Model DS56 Sprinklers Beyond Obstruction Example Layout(Not to Scale) Eave- ► --- -- - Model DS5. Sprinkler(Typ.) B' 8 ® B '8 Ridg• e v v Draft Curtain or Wa /Obstruction(not necessarily full length of spade) Model DS56 Sprinkler to protect — Vr." p p V '� 'ry IV W. V V, for v B' behind obstruction(Required when coverage area exceeds 15') Eav _— Calculation Requirements: Wet System-Most demanding five(5)DD Series Sprinklers and two(2)DS56 Sprinklers Dry System-Most demanding seven(7)DD Series Sprinklers and two(2)DS56 Sprinklers Bulletin 056 July 2022 Reliable Page 11 of 27 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Model GP56 or AH Series Sprinklers Beyond Obstruction Figure 13 Example Layout(Not to Scale) Eaves—►. _._ -_- m m ui m a; Lis Model DD Series Sprinkler(Typ.) Rage— . M— f W R 1it, . Model GP56 or AH Series full (not necessarily Sprinkler to protect behind full length of space) obstruction(maximum 15' between obstruction and eave) m w m w w -� w w Calculation Requirements: Wet System-Most demanding five(S)DD Series Sprinklers and two(2)GP56 or AH Series Sprinklers Dry System-Most demanding seven(7)DD Series Sprinklers and Iwo(2)GP56 or AH Series Sprinklers Model DS56 Sprinklers at Ridge with Model GP56 or AH Series Sprinklers Beyond Obstruction Example Layout(Not to Scale) Figure 14 Cave-- m f m m m m m Model DS5. Sprinkler(Typ.) E^3 tea 1 ® ® V W !b Q 9 9 P_ ® A B Q Da Curtain or Wa i° -` - - - - Model GP56 or AH Serie /Obstruction(not necessarily Sprinkler to protect behindfull length of space) '.. obstruction(maximum 15' between obstruction and eave) m m n m w w w m m • Calculation Requirements: Wet System-Most demanding five(5)DS56 Sprinklers and two(2)GP56 or AH Series Sprinklers Dry System-Most demanding seven(7)DS56 Sprinklers and two(2)GP56 or AH Series Sprinklers Bulletin056 R Page 1 of 27 Julyy202022 www reliablesprinkler.com Model DD Series Sprinklers at Ridge with Model GP56 or AH Series Sprinklers in Dormers Figure 15 Example Layout(Not to Scale) Model DC Series(or Mod- DS56)Ridge Sprinkler 1 - verframed area(Lower hil-. ) trusses may be completely or partially sheathed) Iiiii II.III (hi ifFn) IIIu iI / / / m _- al � � �r�, ��77 r�, ryrye�: ryry�� y� _ pi co— ,.Ill I➢ = fl 1 _ 11 [il W Imo tt=ii W W'-.: W [P-. —n NI— M—lir- — li Model DD Senes(or Mode / �i y D556)Ridge Sprinkler - - ::. :�. / ' ... u n p i (fftifiiIII a \III: Dormer III�IiIII — Cp _ ofiiiiiiII _... Model Series or I GP56 Sprinklers s I I. IIII _.. _..._. lu III I '.— Calculation Requirements Where Attic and Dormer Spaces are NOT Separated*: Wet System-Most demanding five(5)ridge sprinklers and two(2)AH Series or Model GP56 sprinklers when there are four(4) sprinklers or less in dormer.When more than four(4)AH Series or GP56 sprinklers in dormer,separatelycalculate(a)five(5) ridge sprinklers and(b)all AH Series or Model GP56 sprinklers in dormer(up to a maximum 1500 square foot area)and use the greater of the two demands. Dry System-Most demanding seven(7)ridge sprinklers and two(2)AH Series or GP56 sprinklers when there are four(4) sprinklers or less in dormer.When more than four(4)AH Series or Model GP56 sprinklers in dormer separatelycalculate(a) seven(7)ridge sprinklers and(b)all AH Series or Model GP56 sprinklers in dormer(up to a maximum 1950 square foot area), and use the greater of the two demands. *Note:Where attic and dormer spaces are separate,compartmentalized areas,the combined ridge sprinkler and dormer sprinkler calculation is not required. Bulletin 056 Reliable Page 13 of 27 July 2022 www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Standard Spray Sprinklers at Dormer or Cross Example Layout(Not to Scale) Figure 16 Moder D0 Sates(a DS56)Fridge SparMer i 0vedramed area(Lower -- - (!PA '619. Trusses may be completely or partially sheathed) Fr hit) / r \ r \ ModerDDseri (or Mod: \ _. D556)Fridgg e Sprinkler `$ 4'0 ormer \ / • +\ ,. / p , ni"\.o:: " Woolard Spray9 later', 8 . iH41111— _ _ Calculation Requirements When Attic and Dormer Spaces are NOT Separated': Wet System-Most demanding five(5)ridge sprinklers and two(2)standard spray Sprinklers when there are four(4)sprinklers or less in dormer.When more than lour(4)sprinklers in dormer,separatelycalculate the most demanding remote area,including all sprinkler types.per NFPA 13,and use the greater of the two demands.30%remote area increase for sloped ceiling is required,and remote area reduction for use of quick response standard spray sprinklers may be applicable. Dry System-Most demanding seven(7)ridge sprinklers and two(2)standard spray sprinklers when there are four(4)sprinklers or less in dormer.When more than tour(4)sprinklers in dormer,separately calculate the most demanding remote area, including all sprinkler types,per NFPA 13,and use the greater of the two demands.30%remote area increase for sloped ceiling and 30%remote area increase for dry system is required. 'Note:Where spaces are separate,compartmentalized areas,calculate the ridge sprinklers per figures 9 or 10,and the dormers per NFPA 13,and use the greater of the Iwo demands. Bulletin 056 Page 14 of 27 July 2022 Reliable www.reliablesprinkler.com Model DD Series Sprinklers at Ridge with Model DD Series Sprinklers in Dormers Example Layout(Not to Scale) Model DC Series or Mode Sparer I rya) Model 06 SerreS MOC;161DS5E, Sprinkler pair Tyr( V T r; %,ie risir g), a alcrilanon Requirements Wnere Attic and Dormer Scam are NO7Separateu% .Net S'O.lerr-Posl demanding we:Si Model DO Series or 0556 t punkahs at ridge plus up to two 12)sum-leers in dormer Dry Sp:ern-kW:demanding seven ID Model DO Series or OSSS sonaklers al ridge plus up to two(2)spunk rs in dormer 'Rorer Where attic and dormer spaces are separate.compuernentaksed areas,refer to F gores 9 or 10. Model DD Series Sprinklers at Ridge with Model GP56 or AH Series Sprinklers at Eave Fig ure 18 Example Layout(Not to Scale) Note if necessary,a baffle m LE cEcnn no may be added between the Model DD sprinklers and the Model GP56 sprinklers to prevent cold solder. Model DO Serie Sprinkler(Typ.) ",•• REI9 :; if - Model GP56 Sprinkler or Model AH Series Sprinkler to extend ridge sprinkler protection(maximum 15' coverage area) o; on' w 712 zr/ En Calculation Requirements: Wet System-Most demanding live(5)DD Series Sprinklers and two(2)GP56 or AH Series Sprinklers Dry System-Most demanding seven(7)DID Senes Sprinklers and two(2)GP56 or AH Series Sprinklers Bulletin 056 Page 15 of 27 July 2022 e i • www.reliablesprinkler.com Model DS56 Sprinklers at Ridge with Model GP56 or AH Series Sprinklers at Eave Example Layout(Not to Scale) Figure 19 Eave — Note:if necessary,a baffle may be added between the n LTAm m Model DS sprinklers and the Model GP56 or AH Series sprinklers to prevent cold solder. Model DS5. Sprinkler(Typ.) 8 d 8 d m' ® '� 8 .ri m 6 8 B P 9 9 t P Draft Curtain or W. Model GP56 Sprinkler or Model AH Series Sprinkler to extend ridge sprinkler protection(maximum 15' coverage area) _ w w m w rg W w Eave--y- I. Calculation Requirements: Wet System-Most demanding five(5)DS56 Sprinklers and two(2)GP56 or AH Series Sprinklers Dry System-Most demanding seven(7)DS56 Sprinklers and two(2)GP56 or AH Series Sprinklers Model DD Series Sprinklers at Ridge with DS56 Sprinklers at Hip or Ell Example Layout(Not to Scale) Figure 20 MD — — e olah •raft Curtain or Walt Typ, Model.a . iDpkw d - m,iil, oriel DS56 SPrinpar(Typ.) - - SPrnkkr iTYD.) 6 Ito It ® e �,,, / ,iu o pull ainyl 4ruq Draft Curtain or wai(Tyr. l`p®m' OF134 Calculation Requirements: I Wet System-Most demanding Live(5)Model OD Series and/or DS56 sprinklers Wtlg Wel DD Series Dry System-Most demanding nine(9)Model DO Senes and/or DS56 swinuIerlTYpl sprinklers;of which only a maximum of seven(7)must be Model DO Series(ridge)sprinklers Bulletin 056 Page 16 of 27 July 2022 Reliably www.reliablesprinkler.com Model DS56 Sprinklers at Ridge with DS56 Sprinklers at Hip or Ell Example Layout(Not to Scale) Figure 21 wP—.— Malt Curtain or Wel lTysI Mpdal D55 Ij.X4i A _ ---. otlel p558 Sprinkler(Typ ejil $PdnMer(TYPd a e fl �... A A A Ai d' A Ai A d A mca B 9 9 '' / a j V. ter„ v Draft CLdan or Wal(Typ. nw< _ -- ' p ; m rC: tH/wem,, Calculation Requirements: 6:441 ®fit Wet System-Most demanding five(5)Model DS56 sprinklers L ►_ Dry System-Most demanding nine(9)Model DS56 sprinklers rdodems. AI .ran Grlain or wayrypl SPrinNler i7yp.1 M9 Model DD Series Sprinklers at Ridge with Standard Spray Sprinklers at Hip or Ell Example Layout(Not to Scale) Figure 22 nlp---� -- ------ — \ // _._glare'shared areaweh ilaccordanraysSe NEEd N accatlance w�NFPA 19 m m m R / saasstr ioEcl shaded area nth daubed spray spMfers ---- ---- in accordance with ureA 13 - -- --- m nfi 4 sw Model ooseres. Soma¢,Iryo.l Calculation Requirements When Attic and Hip or Ell Spaces are NOT Separated` Wet System-Most demanding five(5)ridge sprinklers and two(2)standard spray sprinklers when there are four(4)sprinklers or less in the hip or ell.When more than four(4)sprinklers in hip or ell,separatelycalculate the most demanding remote area, including all sprinkler types,per NFPA 13,and use the greater of the two demands,30%remote area increase for sloped ceiling is required,and remote area reduction Ion use of quick response standard spray sprinklers may be applicable. Dry System-Most demanding seven(7)ridge sprinklers and two(2)standard spray sprinklers when there are lour(4)sprinklers or less in hip or ell.When more than four(4)sprinklers in hip or el,separaletycalculate the most demanding remote area, including al sprinkler types,per NFPA 13,and use the greater of the two demands.30%remote area increase for sloped ceiling and 30%remote area increase for dry system is required. Bulletin 056 Page 17 of 27 July 2022 Re liaN www.reliablesprinkler.com Model DS56 Sprinklers at Ridge with Standard Spray Sprinklers at Hip or Ell Fig ure 23 Example Layout(Not to Scale) 9 \ j -1—+'miect shaded area r.Eh sandard spray spmI rs \ / in accordance with NFPA 13 se e 'e w y y ®, e y y y v / )a,m � giro stirs Edsalr a, 'ruled shaded area with intesdr mertr --- standard Spray apa,Uers in accadarre with NFPA 13 Ore rdse#1 Model 0 NM.: van CudaM a Wei(Typ.) Sprinder rip Calculation Requirements When Attic and Hip or Ell Spaces are NOT Separated': Wet System-Most demanding five(5)ridge sprinklers and Iwo(2)standard spray sprinklers when there are four(4)sprinklers or less in the hip or en.When more than four(4)Sprinklers in hip or ell,separatelycalculate the most demanding remote area, including all sprinkler types,per NFPA 13,and use the greater of the two demands.30%remote area increase for sloped ceiling is requaed,and remote area reduction for use of quick response standard spray sprinklers may be applicable. Dry System-Most demanding seven(7)ridge sprinklers and two(2)standard spray sprinklers when there are four(4)sprinklers or less in hip or ell.When more than lour(4)sprinklers in hip or ell,separately calculate the most demanding remote area, including all sprinkler types,per NFPA 13,and use the greater of the two demands.30%remote area increase for sloped Bulletin 056 Page 18 of 27 July 2022 Reliable www.reliablesprinkler.com Model DD Series Sprinklers at Ridge and Model AH Sprinklers at Hip and Ell Fig ure 24 Example Layout(Not to Scale) g Hi , ill .c. _; U'.,k/ ` 0 (5m Model AH42 or AH56 Sprinkler i,l ld CO / st See Note A Note:Minimum 2'-0"lateral 110 p /See Note A 0 / / oa offset required between sprinklers when viewed up f O16 the roof slope. 1 I I� On,o l � �, — „. .sa :-.,,, : , u f e_a_ / I IEk1!4 0 Q / III ni\l odel AH Series I 1111 I Note:First1 row of AH sprinklers -F— Sprinkler(Typ.) may be a maximum of 91.0"from eave;however,must be on eave - - - - -;,._ side of girder truss. " Hit odel DD Series Sprinkler(Typ.) Calculation Requirements: Wet System-Most demanding five(5)Model DD Series ridge sprinklers and two(2)AH sprinklers when there are four(4)AH sprinklers or less.When more than four(4)AH sprinklers,separate/ycalculate(a)five(5)Model DD Series ridge sprinklers and two(2)AH sprinklers,and(b)all AH sprinklers(up to a maximum 1500 square foot area)and use the greater of the Iwo demands. Dry System-Most demanding seven(7)Model DD Series ridge sprinklers and two(2)All sprinklers when there are four(4)AH sprinklers or less.When more than four(4)AH sprinklers,separate/ycalculate(a)seven(7)Model DO Series ridge sprinklers and two(2)AH sprinklers,and(b)all AH sprinklers(up to a maximum 1950 square foot area)and use the greater of the two demands. Note A: A single quick-response standard spray upright sprinkler installed in accordance with NFPA 13 may be used for the protection of small areas outside the coverage areas of the specific application attic sprinklers.Demand for the single sprinkler shall be added to the calculations listed above if it falls within the 1500 sf wet system or 1950 sf dry system design area.CPVC piping on wet pipe systems is permitted for supplying individual quick-response standard spray upright sprinklers installed in this manner. Bulletin 056 Page 19 of 27 July 2022 Rel.abld www.refiablesprinkler.com Model DS56 Sprinklers at Ridge and Model AH Sprinklers at Hip and Ell Fi ur Example Layout(Not to Scale) g e 25 fir 0 0 o / Model AH42 or AH56 Sprinkler ,�,;;;, hO Note:Minimum 2'-01 lateralirikD \® See Note A / .: O yj offset required between @:: i sprinklers when viewed up _ _• o :' the roof slope. ® e e tl 8 8' ® 8 B 6 ell) Pre 6 0 - Q. Q Q V. Q Q: Q Q B 9 See Note A u® mu ;ip O ;pd� -m!is^ / ,, / Hi. -- odel AH Series Note:First row of AH sprinklers 1-6— Sprinkler(Typ.) - ^,i..3 m^p may be a maximum of 9'•0"from eave:however,must be on eave Lm® co,,)) side of girder truss. Ridge 8 Drail Curtain or W. 'odel DS56 Sprinkler(Typ.) Calculation Requirements: Wet System-Most demanding five(5)Model DS-56 Series ridge sprinklers and two(2)AH sprinklers when there are four(4)AH sprinklers or less.When more than four(4)AH sprinklers,separatelycalculate(a)five(5)Model DS-56 Series ridge sprinklers and two(2)AH sprinklers,and(b)all AH sprinklers(up to a maximum 1500 square foot area)and use the greater of the Iwo demands. Dry System-Most demanding seven(7)Model DS-56 Series ridge sprinklers and two(2)AH sprinklers when there are four(4)AH sprinklers or less.When more than four(4)AH sprinklers,separately calculate(a)seven(7)Model DS-56 Series ridge sprinklers and two(2)All sprinklers,and(b)all AH sprinklers (up to a maximum 1950 square toot area)and use the greater of the two demands. Note A: A single quick-response standard spray upright sprinkler installed in accordance with NFPA 13 may be used for the protection of small areas outside the coverage areas of the specific application attic sprinklers,Demand for the single sprinkler shall be added to the calculations listed above it it falls within the 1500 sf wet system or 1950 sf dry system design area.CPVC piping on wet pipe systems is permitted for supplying individual quick-response standard spray upright sprinklers installed in this manner. Bulletin 056 Page 20 of 27 July 2022 Reliabld www.reliablesprinkler.com Model AH Series Sprinklers at Ridge and DS56 Sprinklers in Attic(Plan View) Figure 26 Eave — Model DS5 Sprinkler(Typ.) Model A ® ® ® 8 e_ 8 Sprinkler(Typ Ridgc 1,11I vvIIF loll /'I I aa w)1 ur krill LI ; 1 1111 11111 1111 \\II I111 11111 IIII < -- 11111 IIIII \llll �e A. a ® a e ® a ® e e ® Draft Curtain or Wal = Eav Calculation Requirements: Wet System-Most demanding five(5) sprinklers of either type Dry System-Most demanding nine(9)DS56 Sprinklers or(7)AH Series Sprinklers Model AH Series Sprinklers at Ridge and DS56 Sprinklers in Attic(Cross Section) Figure 26A 1"min Model AH Series or 1211 max. standard spray sprinkler 4%.� within 12"of ridge line Wall or Draft Curtain ^b Model DS56 sprinkler Max. 7'-611 Model AH Series Sprinklers used in this arrangement shall have the deflector oriented flat(parallel to the floor),and the frame arms parallel to the ridge line (i.e.,frame window opening toward eaves). Coverage area,flow and pressure requirements,and obstruction rules for AH Series sprinklers to be in accordance with pages 8 and 9 of this bulletin. Reference NFPA 13 when using standard spray sprinklers at peak. Bulletin 056 Page 21 of 27 July 2022 Rel•abl www.reliablesprinkler.com Obstruction Criteria Figure 27 Model DD Series sprinkler M Model DD Series sprinkler Min.gap above Obstruction obstruction greater than 6 (150 mm)max. 3 112"(90 mm) [6 )150mm)in height obstruction height Obstruction Obstruction Additional sprinkler beyond obstruction Additional sprinklers not required due to obstruction 6" (150 mm) or less in Additional sprinklers required beyond obstruction greater than 6"(150 mm)in height with a minimum 3-1/2"(90 mm)gap provided between the top of the height or where a minimum 3-1/2"(90 mm)gap is not provided between the obstruction and the roof deck top of the obstruction and the roof deck. Model DS56 sprinkler Model DS56 sprinkler Min.gap above obstruction Obstruction Obstruction 6 (150 mm)max. 3-1/2"(90 mm) greater thanr.obstruction height 6"(150 mm)in height Additional sprinkler Obstruction mp' beyond obstruction Additional sprinklers not required due to obstruction 6"(150 mm)or Additional sprinklers required beyond obstruction greater than 6"(150 mm)in less in height with a minimum 3-1/2"(90 mm)gap provided between height or where a minimum 3-1/2"(90 mm)gap is not provided between the the top of the obstruction and the roof deck. top of the obstruction and the roof deck. Model DD Series sprinkler Model DD Series sprinkler Horizontal obstruction Horizontal obstruction Additional sprinklers below horizontal obstruction Max.4'-0"(1.2 m)width Greater than 4'-0"(1.2 m)width Additional sprinklers not required below horizontal obstruction 4'-0" Additional sprinklers required below horizontal obstruction greater than 4'-0" (1.2 m)or less in width. (1.2 m)in width. Model DD Series sprinkler Model DD Series sprinkler Horizontal obstruction Horizontal Less than 6"(150 mm)from Min.6"(150 mm)from horizontal obstruction obstruction horizontal obstruction to bottom of rafter to bottom of rafter Additional sprinkler beyond obstruction Additional sprinklers not required beyond horizontal obstruction more than 6" Additional sprinkler required beyond horizontal obstruction less than 6"(150 from bottom of rafter mm)from bottom of rafter. Additional sprinkler not required beyond vertical obstruction(see figure at left)where: W 0 Obstruction width,W Minimum distance between T sprinkler and obstruction, D 1"or less(25 mm or less) 6"(150 mm) 1"to 4"(25 to 100 mm) 1'-0"(300 mm) 4"to 8"(100 to 200 mm) 2'-0"(600 mm) D 8"to 10"(200 to 250 mm) 5'-0"(1.5 m) 10"to 20"(250 to 500 mm) 10'-0"(3.0 m) 20"to 30"(500 to 750 mm) 15.-0"(4.5 m) 30"to 40"(750 to 1000 mm) 20'-0"(6.0 m) 40"to 48"(1000 to 1200 mm) 25'-0"(7.5 m) Provide sprinklers beyond vertical obstructions not meeting the criteria above. Bulletin 056 Page 22 of 27 July 2022 ReW www.reliablesprinkler.com Obstruction Criteria(cont.) Figure 28 Model DD Series sprinkler ! Less than 3'-0'(900 mm) Lees than 3'-0"(900 mm) Min.3'-0"(900 mm) to 1'-0'(300 mm) to 1'-0°(300 mm) ILI clearance betweenclearance between clearance between pace and enclosed space enclosed space ® eck and roof dec -nd roof deck Ala Intermediate level Intermediate level sprinklers sprinklers Additional sprinklers not required beyond enclosed space more than 3-0" beyond enclosed space beyond enclosed space (900 mm from root deck. Additional intermediate level sprinklers required beyond enclosed space less than 3'-0"(900 mm)to 1'-0"(300 mm)from roof deck. Less than 1'-0"(300 mm) Less than 1'-0'(300 mm) clearance between clearance between enclosed space enclosed space and roof deck and roof deck rii Additional sprinklers Additional sprinklers beyond enclosed space beyond enclosed space Additional sprinklers required beyond enclosed space less 1'-0'(300 mm) from roof deck. Min.1'-0"(300 mm) Less than V-0"(300 mm) \ Less than 70%open area deflector to fop of stiffener Men.70%open area deflector to top of stiffener Stiffener(Tye. Stiffener(Typ.) \ Additional sprinklers ----- -1(.- ow stiffeners(TYp.) Max.7-1/2' 1,a mm) Min.1'4"(300 mm) Greater than 7-/2(190 mm) Less than 1'-0'(300 mm) stiffener width gaps between stiffeners stiffener width gaps between stiffeners Additional sprinklers not required below stiffeners meeting all of the following Additional sprinklers required below stiffeners:(1)less than 1'0"(300 mm) criteria:(1)minimum 1'-0"(300 mm)below Reliable Attic sprinklers,(2) below Reliable Attic sprinklers,(2)more than 7(1/2"(190 mm)wide stiffeners, maximum 7-1/2'(190 mm)wide stiffeners,(3)minimum 11-0"(300 mm)gaps (3)gaps between stiffeners are less than 1'-0"(300 mm),or(4)where the area between stiffeners.and(4)minimum 70%open area. of the horizontal plane where the stiffeners are located is less than 70%open. Note: Reliable Attic sprinklers may be installed directly on pipe up to 2-1/2" NPS. For 3"NPS and larger pipe,the Nominal 1-1/2'(38 mm) obstruction rules for Extended Coverage Upright Spray maximum gap Sprinklers shall be followed. Alternate Allowable Framing Method A maximum 1.112 in(38 mm)gap between sheathing and top of structural framing members(such as that formed by nailers laid flat)is acceptable. Bulletin 056 Page 23 of 27 RelIab July 2022 l www.reliablesprinkler.com Installation Install Reliable Attic Sprinklers only in the orientation indicated in Figure 28. Figure 29 provides additional select installation criteria for each sprinkler model. Installation Orientation Figure 29 Installation Dimensions Figure 30 Model DD Series Model DD Series Max.6"(150 mm) horizontally from center of sprinkler to ridge Install Model DD Series sprinklers with the deflector parallel to the floor and arrows on deflector pointing down the roof slope in both 17"(430 mm)min. directions. to 21"(530 mm)max. top of deflector Model DS56 below peak, ridge,or deck Model DS56 Min.30"(762 mm)to max.42"(1067 mm) horizontallyfrom \V� draft curtain or wall to deflector Install Model DS56 sprinklers with the frame arms perpendicular Min.9"(230 mm)to max.13"(330 mm) to the roof deck (parallel with lower eave) and the arrow on the top of deflector to roof deck deflector pointing down the roof slope. a` Min.8"(200 mm) Model GP56 and AH Series top of deflector above bottom of draft curtain Model GP56 9 Min. 9" (230 mm) to max. 13"(330 mm) top of deflector to roof deck Install Model GP56 sprinklers with the deflector parallel to the roof deck and the arrow on the deflector pointing down the roof slope. Install Model AH Series sprinklers with the deflector parallel to the roof,and frame arms parallel with the lower eave of the protected space. Model AH42/AH56 Min. 1"(25 mm)to max.3"(76 mm) top of deflector to bottom of truss top chord Bulletin 056 Page 24 of 27 ea■ b�� July 2022 ia wwwreliablesprinkler.com Note:Where Reliable Attic Sprinklers are installed on wet-pipe sprinkler systems with CPVC pipe, the CPVC pipe must be protected in accordance with the pipe manufacturer's installation instruction as well as the requirements in Figure 30. Installation Requirements for Use of Reliable Attic Sprinklers with Listed CPVC Pipe Figure 31 CPVC Pipe Min.18" (450 mm) Heat producing or releasing device Maintain at least 18"(450 mm)between CPVC pipe and heat producing or releasing devices. Max. 1'-0" Offset(A)must not exceed 6"(150 mm) (300 mm) Direct Mount Angled Sprig t' Armover Sprig ' Vertical Sprig CPVC Riser IIIMIIMCL Install sprinklers on CPVC pipe only in the following configurations: (1) directly mounted to a fitting on the branch line pipe, (2) on an angled sprig where the horizontal distance between the sprinkler and the branch line does not exceed 6" (150 mm), (3) on an armover sprig where the horizontal distance between the sprinkler and the branch line does not exceed 6"(150 mm), or(4)on a vertical sprig. Locate a sprinkler within 1'-0" (300 mm) horizontally of CPVC risers Model GP56 or AH Series sprinkler ��Model GP56 sprinkler Max.3'-0" (900 mm)_ Angled sprig Noncombustible Noncombustible Vertical sprig Min.6"(150 mm) Max. (3 m)-0" Min.6"(150 mm) insulation insulation (e.g.,fiberglass) F�__�i114F4 (e.g.,fiberglass) �_ Joist M n. 1'- i� Joist—\ St�0 I Mm. � Min. 1'-0" Min.1'-0" (300 mm) (300 mm) Min.1'-0" Min.mm) �-I(300 mm) (300 mm) Branch lines over joists must be protected with a minimum 6" (150 Branch lines over joists must be protected with a minimum 6" (150 mm) thickness of noncombustible insulation (e.g., fiberglass). A mm) thickness of noncombustible insulation (e.g., fiberglass). A maximum of 3'-0" (900 mm) of an angled sprig may extend above maximum of 10'-0" (3 m) of a vertical sprig may extend above the the insulation to supply Model GP56 and AH Series sprinklers. insulation to supply Model GP56 sprinklers. 'del GP56 or AH 'del GP56 or AH Max.3'-0" Series sprinkler Series sprinkler 900 mm)_ Angled sprig (900 mm)_ Angled sprig Noncombustible Min.6"(150 mm) Noncombustible-- n.6"(150 mm) insulation insulation (e.g.,fiberglass) (e.g.,fiberglass) Joist Joist Branch lines between joists must be protected with a minimum Branch lines between joists must be protected with a minimum 6" (150 mm) thickness of noncombustible insulation (e.g., 6" (150 mm) thickness of noncombustible insulation (e.g., fiberglass) either within the joist bay or on top of the joists. A fiberglass) either within the joist bay or on top of the joists. A maximum of 3'-0" (900 mm) of an angled sprig may extend maximum of 3'-0" (900 mm) of an angled sprig may extend above the insulation to supply Model GP56 and AH Series above the insulation to supply Model GP56 and AH Series sprinklers. sprinklers. Bulletin 056 Page 25 of 27 July 2022 Rel ab www.reliablesprinkler.com Installation Requirements for Use of Reliable Attic Sprinklers with Listed CPVC Pipe Figure 32 �/ Model GP56 sprinkler Model GP56 sprinkler Noncombustible Max.p�� Vertical sprig Vertical sprig Min.6"(150 mm) Max. t0'-0' / insulation (3 m) u Min.6"(150 mm) (e.g.,fiberglass) �� , �- �.- Noncombustible (3m) �1 {> I���, insulation Joist I. A ����, (e.g.,fiberglass) ,iv, Joist- Branch lines between joists must be protected with a minimum 6" Branch lines between joists must be protected with a minimum 6" (150 mm)thickness of noncombustible insulation(e.g.,fiberglass) (150 mm)thickness of noncombustible insulation(e.g.,fiberglass) either within the joist bay or on top of the joists. A maximum of either within the joist bay or on top of the joists. A maximum of 10'-0"(3 m) of a vertical sprig may extend above the insulation to 10'-0"(3 m) of a vertical sprig may extend above the insulation to supply Model GP56 sprinklers. supply Model GP56 sprinklers. Model AH Series Model AH Series } sprinkler } sprinkler Vertical sprig Any Vertical sprig Length Any Length Noncombustible insulation Min.6"(150 mm) Noncombustible Min.6" 150 mm (e.g.,fiberglass) - insulation ( ) Joist ��►j�0{il, (e.g.,fiberglass) �� Min.1'-0" I Min.1LO" (300 mm) (300 mm) f Joisl Branch lines over joists must be protected with a minimum 6" Branch lines over joists must be protected with a minimum 6" (150mm)thickness of noncombustible insulation(e.g.,fiberglass). A (150mm)thickness of noncombustible insulation(e.g.,fiberglass) vertical sprig of any length may extend above the insulation to supply either within the joist bay or on top of the joists. A vertical sprig of any Model AH Series sprinklers. length may extend above the insulation to supply Model AH Series sprinklers. Caution: 1. Insulation required by Figures 30 and 31 is for fire protection Model AH Series purposes and not for freeze protection. sprinkler 2. Follow installation requirements of the CPVC pipe manufacturer Vertical sprig and listing,including vertifying compatibility of any insulation or Any other materials used with CPVC pipe. Length 3. Sprig ups to Model GP56 and AH Series sprinklers must be Noncombustible Min.6"(150 mm) properlysecured and supported in accordance with NFPA 13 insulation requirements. (e.g.,fiberglass) Joist Branch lines over joists must be protected with a minimum 6" (150mm)thickness of noncombustible insulation(e.g.,fiberglass) either within the joist bay or on top of the joists. A vertical sprig of any length may extend above the insulation to supply Model AH Series sprinklers. Bulletin 056 Page 26 of 27 July 2022 Ra labl www.reliablesprinkler.com Installation Maintenance Model DD Series, Model GP56, and Model AH Series sprinklers Reliable Attic sprinklers should be inspected and the sprinkler are installed with the W2 wrench.The Model DS56 wrench is used system maintained in accordance with NFPA 25, as well as the to install Model DS56 sprinklers. The use of any other wrench to requirements of any Authorities Having Jurisdiction. install Reliable Attic sprinklers is not permitted and may damage Prior to installation, sprinklers should remain in the original cartons the sprinkler.Place the specified wrench over the sprinkler until the and packaging until used. This will minimize the potential for wrench engages the wrench flats. Do not wrench any other part damage to sprinklers that could cause improper operation or non- of the sprinkler assembly.Tighten the sprinkler into the fitting after operation. applying a PTFE based thread sealant to the sprinkler's threads. Do not clean sprinklers with soap and water,ammonia liquid or any Recommended installation torque is specified in Table J. other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Installation Torque Table J Replace any sprinkler which has been painted (other than factory Recommended applied). Replace any sprinkler which has been damaged. A Installation Torque stock of spare sprinklers should be maintained to allow quick Sprinkler Threads (min.-max.) replacement of damaged or operated sprinklers. ft-lb N m Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. h"NPT or I807-1 R1/2 8-18 11-24 '/."NPT or ISO7-1 R3/4 14-20 19-27 Listing & Approval Agency Do not exceed the maximum recommended torque.Exceeding the Underwriters Laboratories, Inc. and UL Canada(cULus) maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when placing or removing the wrench Listing Category: Sprinklers,Automatic and Open from the sprinkler to avoid damage to the sprinkler. Guide Number:VNIV,VNIV7 Installation Wrenches Figure 33 Guarantee Model w2 Wrench For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions,visit www.reliablesprinkler.com. Ordering Information 41 Specify the following when ordering. Sprinkler For Models DD56,DD80,GP56,AH42,and AH56 sprinklers • Model (DD56-6, DD56-27, DD80-6, DD80-27, DS56, GP56,AH42,AH56) • Threads(NPT or ISO 7-1) Model DS56 Wrench Sprinkler Wrench • Model W2 (for Model DD Series, Model GP56, and Model AH Series sprinklers) :. • Model DS56 (for Model DS56 sprinklers) For Model DS56 sprinklers N- rn 0 ti rn rn rn am rn z_ Bulletin 056 27 0 Jul 2022 iablEt Page 27 Y www.reliabiesprinkler.com Bulletin 014 August 2022 W ® Model Fl FR Series ne eli � Quick Response Glass Bulb Sprinklers 0 N Model F1FR56 Sprinkler Types T ;, N Standard Spray Upright Standard Spray Pendent Ira ,w" Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall ...''; ... Model FIFR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent x T.- Horizontal Sidewall co Model F1FR56 Concealed Sprinkler Types 11111 _ - x Standard Spray Pendent .73 Model F1FR42, F1 FRXLH & F1 FR28 Sprinkler L,w' N Types Standard Spray Upright Vertical Sidewall Horizontal Sidewall Recessed o Standard Spray Pendent Pendent/F1/F2 v a xg Model F1FR40 Sprinkler Types YStandard Spray Pendent + � ' o Model F1FR42, F1FR40, FIFRXLH & F1FR28 Recessed Sprinkler Types `'° " h " : " "c Standard Spray Pendent • Model F1FR56LL& F1FR42LL Low Lead Sprinkler Recessed Concealed Recessed N co Types Horizontal Sidewall Pendent Pendent/FP $ Standard Spray Pendent with less than 0.25% Lead Con- tent Listing &Approvals ` 0 The following organizations provide Listings or Approvals for various Model F1 FR series sprinklers. See the Design and N Installation table in this Bulletin for information on specific XLH Upright XLH Pendent XLH Recessed N listings and approvals applicable to each sprinkler. Pendent F1/F2 m 1. Underwriters Laboratories Inc. and Certified for Cana- a da (cULus) in accordance with ANSI/UL199. Product Description 1-di 2. FM Approvals (FM) Reliable Model F1 FR series sprinklers 0 3. Loss Prevention Certification Board (LPCB) are quick response automatic sprinklers .• N 4. VdS Schadenverhutung GmbH (VdS) with a glass bulb thermal element. Model - N 5. Underwriters Laboratories Inc. and Underwriters Lab F1 FR series sprinklers are Standard Spray oratories of Canada Certified for Health Effects to NSF/ sprinklers,with the exception of the Model ANSI Standard 61 Annex G (ULH) F1FR56 Conventional sprinkler which is XLH Recessed 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- an Old-style/Conventional sprinkler. Pendent FP CPD-40251 (RA1425), 0786-CPD-40252 5) The Model F1FR Series automatic sprinklers utilize a 3.0 (EC) mm frangible glass bulb. These sprinklers have demonstrated 7. WaterMark certified. Certificate Number 23347. (WM) response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response UL Listing Category enables the Model F1 FR Series sprinklers to apply water to a Sprinklers,Automatic&Open(VNIV) fire faster than standard-response sprinklers of the same tern- Quick Response Sprinkler perature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule. This glass bulb is specially constructed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in Model Fl FR Series sprinklers must be installed with the Reli- both the liquid and vapor phases.The vapor phase can be seen able sprinkler installation wrench identified in the Design and as a small bubble.As heat is applied,the liquid expands,forcing Installation Information table in this Bulletin. Any other wrench the bubble smaller and smaller as the liquid pressure increases. may damage the sprinkler. A leak tight sprinkler joint can be Continued heating forces the liquid to push out against the bulb, obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not causing the glass to shatter,opening the waterway and allowing tighten sprinklers over the maximum recommended installation the deflector to distribute the discharging water. torque. Exceeding the maximum recommended installation Model Fl FR Series sprinklers provide a wide range of options torque may cause leakage or impairment of the sprinkler. where quick-response,glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal side- Model F1FR Series Recessed sprinklers are to be installed wall, and vertical sidewall deflectors as shown in Fig. 1, Fig.2,or Fig. 3,as applicable to the specific • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 model being installed.The Recessed Escutcheon Data table in metric), and 5.6 (80 metric) the Bulletin identifies the only recessed escutcheons that are • Flush, recessed, and concealed installations permitted to be used with each Model Fl FR Series Recessed See the Design and Installation Information table in this Bul- sprinkler.The use of any other recessed escutcheon will void all letin for information on the approvals and availability of specific approvals and negate all warranties. 2 Model F1FR series sprinkler configurations. Concealed Sprinklers a Model F1FR Recessed Pendent and Recessed Horizontal Model F1FR Series Concealed Pendent sprinklers are to = Sidewall sprinklers are required to be used with Reliable Model be installed as shown in Fig. 4 or Fig. 5, as applicable to the x F1, F2, or FP recessed escutcheons. See the Recessed Es- selected cover plate. Model F1FR56 Concealed Pendent and cutcheon Data table in this Bulletin for listing and approval infor- Model F1 FR56LL Concealed Pendent sprinklers have a facto- co mation with each specific Model F1FR series sprinkler. Model ry-installed Model CCP cup.A protective cap is installed at the YN F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are 9 factory that should remain on the sprinkler until the sprinkler is a friction fit assembly allowing for 3/4-inch (19mm) and 1/2- installed and should then be reinstalled on the sprinkler until the 6.. inch(12.7mm)of adjustment, respectively. Model FP recessed cover plate is installed.The concealed sprinkler assemblies are escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) completed by the installation of a Model CCP push-on/thread- ed'Y threaded adjustment. off cover plate assembly.The cover plate and sprinkler cup as- 4- Model F1 FR56 Concealed Pendent and Model F1 FR56LL semblies are joined using a cover plate skirt with flexible tabs Concealed Pendent sprinklers are required to be used with for threaded engagement. A choice of two Model CCP cover N Model CCP cover plates.A standard profile Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch plate is available that provides up to 1/2-inch(12.7mm)of cover (8mm) of cover adjustment. Do not install Model F1FR Series plate adjustment. In addition, a low profile Model CCP cover Concealed Pendent sprinklers in ceilings which have positive nplate is also available that provides up to 5/16-inch (8.0mm)of pressure in the space above. 0 cover plate adjustment. See the Design and Installation Infor- Model F1FR Series Concealed Pendent sprinklers require o mation and Listed and Approved Temperature Ratings tables a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The in this Bulletin for further information on approved cover plate Model W4 wrench is used to engage the sprinkler wrenching sur- options. faces and to install the sprinkler in the fitting.Remove the protective Application cap to install the sprinkler,then reinstall the protective cap until the y Model F1FR Series sprinklers are intended for use in ac- cover plate is installed.When inserting or removing the wrench from cordance with NFPA 13, FM Property Loss Prevention Data the sprinkler/cup assembly,care should be taken to prevent dam- coN Sheets, and the requirements of the Authority Having Juris- age to the sprinkler. Do not wrench any other part of the sprinkler/ wdiction. Care must be exercised that the k-factor, tempera- cup assembly. Installation is completed by removing the protective o ture rating, deflector style, and sprinkler type are in accor- cap from the sprinkler and pushing the cover plate onto the cup. z dance with the requirements of the applicable design and Final adjustment is made by hand turning the cover plate until the Ninstallation standards. In addition, Model F1FR Series sprin- skirt flange makes full contact with the ceiling.Cover plate removal klers must be used in accordance with their listings and ap- requires turning the cover plate in the counter clockwise direction. provals, as well as the information provided in this Bulletin. After installation,inspect all sprinklers to ensure that there is a gap Installation between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Glass bulb sprinklers have orange bulb protectors or protec Concealed cover plate/cup assemblies are listed only for use tive caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are with specific sprinklers. The use of any concealed cover plate/ designed to install sprinklers with bulb protectors in place. Re- cup assembly other than the Reliable Model CCP with Model move the bulb protector at the time when the sprinkler system is F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed placed in service for fire protection. Removal of the bulb protec Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not spe- for before this time may leave the bulb vulnerable to damage. cifically listed my prevent good fire protection and will void all Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. guarantees,warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Nominal Nominal Nominal K-factor Orifice Deflector/ Sprinkler Installation Listings Approval Model Diameter Orientation Height Wrench SIN and Notes US Metric inches mm inches mm Approvals Pendent 2.25 57 W2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 W4 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 Y F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS c •a. c Recessed Pendent 2.25 57 W4 RA1418 VdS co Pendent 2.25 57 W2 RA1413 cULus 2 I X F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 'O Upright 2.25 57 W2 RA1423 cULus 1,2 co N F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH a' Recessed Pendent 2.25 57 W4 RA1410 cULus, ULH F1FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 0 Y (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 Y cULus, FM, Pendent 2.25 57 W2 RA1414 LPCB,VdS, EC, 1,2,3,4 5 to c o cULus, FM, Recessed Pendent 2.25 57 W4 RA1414 LPCB,VdS, EC, 1,2,3,4 WM a) F1FR56 5.6 80 1/2 15 cULus,VdS,EC, ,D Concealed Pendent 2.25 57 W4 RA1414 WM 5,6 a i cULus, FM, o Upright 2.25 57 W2 RA1425 LPCB,VdS,EC, 1,2,3,4 m WM "Conventional LPCB,VdS,EC, (Pendent or Upright)" 2.25 57 W2 RA1475 WM 4 a) Pendent 2.25 57 W2 RA1415 cULus, ULH 1 a) F1 FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 W4 RA1415 cULus, ULH co Concealed Pendent 2.25 57 W4 RA1415 cULus, ULH 6 d Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 zw F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 W4 RA1435 cULus, FM 8 Sidewall c.i Vertical Sidewall(Pen- cULus,FM, F1FR56 5.6 80 1/2 15 2.25 57 W2 RA1485 1,2,3,9 0.1 dent or Upright) LPCB c (1)cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. as (2)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (3)Available with FM approved Polyester coating in black or white. ()Available with LPCB and VdS approved Polyester coating. (5)VdS and EC approvals of the F1FR56 Concealed Pendent sprinkler are for 155°F(68°C)temperature rated sprinklers only.VdS approved sprinklers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. (S)Model F1FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates,available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/16-inch(8.0 mm)of adjustment. (1)cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches(102mm to 305mm).FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (8)cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9)The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Deflector! 100°F(38°C) Max.Ambient 150°F(65°C)Max.Ambient 225°F(107°C)Max. Model Orientation Temp. Temp. Ambient Temp. 135°F(57°C) 155°F(68°C) 175°F(79°C) 200°F(93°C) 286°F(141°C)Temp. Temp. Rating Temp. Rating Temp.Rating Temp.Rating Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS Pendent cULus F1FR42 Recessed Pendent cULus Upright cULus .x F1FR42LL Pendent cULus, ULH .c Recessed Pendent cULus, ULH ca Pendent cULus = FIFRXLH Recessed Pendent cULus X Upright cULus Pendent cULus,FM, LPCB,VdS,EC,WM m Recessed Pendent cULus,FM,LPCB,VdS,EC,WM v Concealed Pendent* cULus,WM cULus,VdS,EC, cULus,WM FIFR56 WM o Upright cULus, FM,LPCB,VdS, EC,WM Y "Conventional (Pendent or Upright)" LPCB,VdS, EC,WM Y Pendent cULus,ULH FIFR56LL Recessed Pendent cULus, ULH N Concealed Pendent* cULus, ULH o Horizontal Sidewall cULus, FM Fl FR56 Recessed Horizontal > Sidewall cULus, FM Vertical Sidewall(Pen- "raF1 FR56 dent or Upright) cULus,FM,LPCB a * Model F1 FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For In- a) termediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. a m a) Recessed Escutcheon Data V N Listed and Approved Recessed Escutcheons a Model Deflector/ra Model F1 Model F2 Model FP cT. Orientation (Fig. 1 &3) (Fig. 1 &3) (Fig.2) SIN Li 3/4-inch(19mm) 1/2-inch(12.7mm) 1/2-inch(12.7mm) z adjustment adjustment adjustment FIFR28 Recessed Pendent cULus cULus cULus RA1411 o FIFR40 Recessed Pendent VdS VdS VdS RA1418 N FIFR42 Recessed Pendent cULus cULus cULus RA1413 as FI FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus,ULH RA1410 FIFR42XLH Recessed Pendent cULus cULus cULus RA1413 F1 FR56 Recessed Pendent cULus, LPCB,VdS, cULus,FM,LPCB, cULus,VdS, EC,WM RA1414 EC,WM VdS, EC,WM FIFR56LL Recessed Pendent cULus, ULH cULus, ULH cULus,ULH RA1415 FI FR56 Recessed Horizontal Sidewall cULus cULus,FM cULus RA1435 4. 2 1/4"HOLE OIA. [57.2mmJ 1 15/16"OH [49.2mmJ rs---i==-i7 1"X 1/2" REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER I WRENCH BOSS \ \ / FACE OF FITTING / TO FACE OF CEILING DIMENSION li —i II EI ESCUTCHEON II II AT MAXIMUM RECESS = 1.25.4mm] r��T� �; AT MINIMUM RECESS 3/8(9.5mm] m Ff ESCUTCHEON i1 {��//1// F2 ESCUTCHEON N 3/4.19mm] i�1 ' -7 AT MAXIMUM RECESS = 3/4(19mm] C ADJUSTMENT II ®astl� II AT MINIMUM RECESS = 3/8[9.5mm] •a F2 ESCUTCHEON 'III _—� IIII 'i/�A 1/2[12.7mm] iltl j,li, CO ADJUSTMENT I��I�� �I� 1 6 FI ESCUTCHEON J I AT MAXIMUM RECESS = 7/8[22.2mm] X :1 : [32,n,J AT MINIMUM RECESS = 1-5/8741.3mm] c F2 ESCUTCHEON to ,,dg gi AT MAXIMUM RECESS = 1-11/8"28.6mm `R==I,' AT MINIMUM RECESS = 1-5/8T41.3mm] N � d 2 27/32"DIA. Y [72.2mm] N Fig. 1 13 En Model F1FR56, F1FR56LL, F1FR42, F1 FR40, F1FR42LL, F1FRXLH & o F1 FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon y 43 > a) a) R r -�- a L - 3 ___--_ 0 I I 1" X 1/2" REDUCER al I 2 5/8" DIA. (66.7mm] . HOLE IN CEILING ED m w 2 5/16" DIA. (58.7mm] a) I .. a) CUP r w m L a CEILING Lii _�1♦ FACE OF FITTING "III ����� III TO FACE OF CEILING z - -- h� �o fill.' 1: DIMENSION j , „Jill AT MAXIMUM RECESS = 1-1/2-38mm] N ........I III III AT MINIMUM RECESS = 1[25.4mm] i . - � 1%%. ♦ -� I AT MAXIMUM RECESS = 9/16[14.3mm] %2[72.7mm] '�!„�� AT MINIMUM RECESS = 1[25.4mm] ADJUSTMENT .....fa fir......, �,•--3.1/4 DIA. f [82.6mm] Fig. 2 Model F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON IF AG AT MAXIMUM RECESS = 1[25.4mm] AT MINIMUM RECESS = 3/8[9.5mm] Fl ESCUTCHEON 114 F2 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8"[34.9mm] AT MAXIMUM RECESS = 3/4-19mm] AT MINIMUM RECESS = 2-1/16752.4mm] AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[41.3mm] 2 1/4" HOLE DIA. - 1/8„ AT MINIMUM RECESS = 2-1/16[52.4mm] [57.2mm] ` [3.2mm] 1" X 1/2" REDUCER -� _r N 1I1 \�--r-1�i (1) L I�iillll' mni, p 4"-12" Y 1 15/16" DIA._Viii 1�11�'�I���� i „' c w� }�Q`P [101.6mm 304.8mm] -c [49.2mm] : i +11 2 27 32" DIA. Uai I Hill IIIIIIIIIIII� ' / CEILING TO 1 ` i (72.2mmJ DEFLECTOR x Y � 11 cc TURN COLLAR UNTIL 0 TIGHT AGAINST SPRINKLER �\y c4 WRENCH BOSS. oilLi F1 ESCUTCHEON y f-3/4[l9mm] ADJUSTMENT o F2 ESCUTCHEON v 1/2[12.7mm] ADJUSTMENT m N wmtax L- RECESSED HSW W/F1 OR F2 ESCUTCHEON 0 c (1) FM APPROVED FOR 4" — 6" [101.6MM — 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. 0 72 Fig. 3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon a) to E. 1" x 1/2" REDUCING TEE OR ELBOW II 3 11 Itil N — — '---1 F--' 2 5/8" DIA. m 2 5/16" DIA — HOLE IN CEILING a CUP = ___ S di — _._ �I 05 tl�ICI 1 1/2" MAX. O //7. .:-/f I _o II Ziiiiliiii� 4i od FACE OF FITTING N ��'_ - Ill II _ _ __ __ _TO FACE OF CEILING N ' "` """" DIMENSION N sa CEILING) ,1` ]II 1/2" MAX. 15/16" COVER ADJUSTMENT COVER PLATE — ASSEMBLY 3 5/16" DIA. - - SPRINKLER — —,/ CONCEALED, 1/2" ADJUSTMENT 017FDDIA Fig. 4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment- Model CCP cover plate 6. 1" x 1/2" REDUCING TEE OR ELBOW li.—______ ,, J 2 5/8" DIA. 2 5/16" DIA — — HOLE IN CEILING CUP =► ,i l I 6111W-31-1�111 1 1/2" MAX. �.I M n�J� FACE OF FITTING ` J TO FACE OF CEILING j.;.:771.Y. Ill �.. f.—�.—,,,,, DIMENSION CEILING -- \. - /� ....---- 5/16" MAX. J = 3/4" 43 COVER ADJUSTMENT c c COVER PLATE— / 2 ASSEMBLY 3 5/16" DIA. - - X SPRINKLER / -o c f° CONCEALED, 5/16" ADJUSTMENT o17rco24. N Y Fig. 5- Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16- q inch (8.0mm) adjustment- Model CCP cover plate v o Maintenance (.4The Model F1FR Series sprinklers should be inspected and Material Data o the sprinkler system maintained in accordance with NFPA 25. Frame: DZR Brass, QM Brass,or Low Lead Brass o Do not clean sprinklers with soap and water, ammonia or any Deflector: CDA Alloy 220,260,or 510 .L other cleaning fluids.Remove dust by using a soft brush or gen- Load ScrewkPintle: CDA Alloy 360 or 544 tie vacuuming. Replace any sprinkler which has been painted Cup: CDA Alloy 651 or 693 a (other than factory applied)or damaged in any way.A stock of Washer: Nickel Alloy 440 or 360,coated with PTFE Q spare sprinklers should be maintained to allow quick replace- Adhesive Tape = ment of damaged or operated sprinklers. Bulb: Glass Finishes (1)(2) co Standard Finishes OrderingInformation Sprinkler Escutcheon Cover plate 3 Bronze Brass Chrome Specify: o Chrome Chrome White 1. Sprinkler Model: F1 FR28 F1 FR40 F1 FR42 0 White Polyester(3)I6)(7) White p [ ][ ][ ] m Special Application Finishes [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] m Sprinkler Escutcheon Cover plate 2. Sprinkler Deflector/Orientation: [Pendent][Recessed a Electroless Nickel Pendent U rl ht Conventional Horizontal w PTFE(3)4) Stainless Steel Bright Brass ][ p g ][ ][ Sidewall] O Black Polyester(3)(6)O Bright Brass Black [Recessed Horizontal Sidewall][Vertical Sidewall] Z Bright Brass(5) Black Off White 3. Sprinkler threads: [1/2-inch NPT][ISO7-R1/2] o ( )][Off Whiter) Off White Satin Chrome 4. Sprinkler Temperature Rating: [135°F (57°C)][155°F N Satin Chrome Satin Chrome 68°C 175°F (79°C)][200°F (93°C)][286°F 141°C c (1)Other finishes and colors may be available on special order. Consult the ( )][ ( )][ ( )] factory for details. 5. Sprinkler Finish (2)Paint or any other coating applied over the factory finish will void all approvals 6. Escutcheon Model: [F1][F2][FP] and warranties. 7. Escutcheon Finish (where applicable) (3) cULus Listed as Corrosion Resistant. 8. Cover plate Model: [standard profile CCP 1/2-inch (4) FM Approved as Corrosion Resistant for SIN RA1414, RA1425, RA1435, (12.7mm) adjustment][low profile CCP 5/16-inch and RA1485. (5) 200°F(93*C)maximum temperature rated sprinkler only. (8.0mm) adjustment] (6)VdS Approved for RA1425,RA1414,RA1418,and RA1475. 9. Cover plate Temperature Rating: [135°F (57°C) for use in LPCB Approved for RA1425,RA1414,and RA1475. with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note:When Model F1FR Series Recessed sprinklers are ordered, the sprin- klers and escutcheons are packaged separately. 7. Reliable . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many pre- cision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system J • Adjustable automatic sprinklers • Sprinkler emergency cabinets Y • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards 45 • Open sprinklers • Inspectors test connections 0 O • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors o • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. Recycled p (800)431-1588 Sales Offices Paper Reliable (800)848-6051(914)829-2042 Sales Fax Corporate Offices Revision lines indicate updated or new data www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.08/22 PIN 9999970300 Bulletin 055 March 2022 ® Model DH80 Dry Extended Coverage Horizontal Sidewall Sprinkler cULus Listed Features • Coverage for long and narrow light hazard spaces such as hallways,decks, and rooms • Coverage area up to 28 ft(8.5m) long and 14 ft(4m)deep • Available in four trim styles and a variety of finish combina- tions. # I ) 1 2 �,. iw15hk4 .. .� .i 7q* Product Description The Reliable Model DH80 Dry Extended Coverage Horizontal Sidewall Sprinkler is a quick-response sprinkler utilizing a sensitive 3mm glass bulb thermal element listed for use in light hazard applications. DH80 Dry EC HSW with standard escutcheon Dry sprinklers are intended for use on wet,dry, and preaction systems to protect indoor and outdoor areas that are subject to freezing.When used on wet systems, it is important that a minimum exposed length of barrel inside the face of the wall or Application insulation is provided to offset conduction of potentially freezing temperatures from the unconditioned(sprinkler)end along the The Model DH80 is a horizontal sidewall dry sprinkler intended for barrel.See Figure 6 for guidelines on using dry sprinklers on wet installation in light hazard occupancies in accordance with NFPA systems. 13. These sprinklers are designed to provide fire protection in long and narrow spaces such as hallways,corridors,decks Environments where dry sprinklers are employed are often and rooms up to 28 feet(8.5m)wide and 14 feet(4.3m)deep. corrosive. For this reason, Model DH80 dry sprinklers have a Model DH80 sprinklers are rated for 175 psi (12 bar)and can be special wax fillet placed in the gap between the cup that mounted between 4 and 12 inches(102 and 305mm)down from supports the bulb and the wrenching boss.This wax prevents the ceiling. contaminants from entering the internal portion of the drop nipple and must not be removed. Table A Max.Working Maximum Coverage Area Sprinkler Sprinkler Model Pressure Width x Length Flow Rate Pressure g gpm (L/min) psi (bar) Identification psi(bar) ft x ft(m x m) Number(SIN) DH80 Dry EC 250(17.2) 28 x 14(8.5 x 4.3) 40(151) 25(1.7) RA5532 www.rellablesprinkler.com Model DH80 EC Horizontal Sidewall Sprinkler SIN RA5532 Technical Specifications Sprinkler Finishes Style: See finish combination tables on following Extended Coverage pages Horizontal Sidewall _ Threads:1"NPT or ISO7-1 R1 Sensitivity Nominal K-Factor:8.0(80) Quick Response Max.Working Pressure:175 psi(12 bar) Max.Spacing:28 ft(8.5m) Temperature Ratings Min.Spacing: 14 ft(4.3m) 155°F(68°C) 175°F(79°C) i+iiitt Material Specifications 200°F(93°C) Inlet Fitting:Brass Alloy Flip Disk:Brass Alloy Recessed Escutcheons/Cover Plates Seal:PTFE Coated Belleville Spring Standard Escutcheon Outer Tube:Galvanized Steel Pipe HB Escutcheon Sprinkler Frame:Brass Alloy FP Escutcheon Bulb Insert:Copper Alloy SWC Cover Plate Thermal Element:Glass Bulb Shown here with standard escutcheon. Deflector:Bronze Alloy Listings and Approvals See pages 3-6 for additional trim styles Load Screw:Brass Alloy cULus Listed for Light Hazard Model DH80 EC HSW Coverage Area Figure 1 28'[8.5m]Maximum Spacing 14'[4.3m]Minimum Spacing MODEL DH80 DRY SPRINKLER Wall de le // / 4"[100mm]Min.from Ceiling / / Floor / 12"[300mm]Max.from Ceiling Coverage Area 28'[B.Sm] ' ]� DHaODRYCOVAREA \ 14'[4.3m] Bulletin 055 Page 2 of 10 March 2022ieliable www.reliablesprinkler.com Model DH80 Dry Sprinkler with Standard Escutcheon Figure 2 Ceiling — --1/2"[12mm] 1-13/16"" 4"[100mm]Min. Sprinkler Can [46mm] 12"[300mm]Max. System Tee 4, r rI Inlet Fitting 1 r III/ ..,,,,\ \ I\ I IIII I I `�' III lift . 7- ----- r „... II , 6mDim [54mm]Hole in Wall 1/2"[12mm] Nominal O5SsTD-A Protrusion — . 1/2"[12mm] Escutcheon Adjustment 1"[25mm] •! Escutcheon \ Nominal Position Adjustment of Escutcheon - "A"Dimension DH80 DRY HSW SPRINKLER, STANDARD ESCUTCHEON "A" Dimension = 2" to 36" (50mm to 900mm) Finish Combinations:Standard Escutcheon Sprinkler Escutcheont2>t3t Bronze Polished Stainless Steel Bronze Laquered Brass Chrome Polished Stainless Steel t""iF 1. '• White Polyester+') White Polyester Black Polyesterni Black Polyester Custom Color Polyester/) Custom Color Polyester Electroless Nickel PTFEi'r Polished Stainless Steel Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is 316 stainless steel. Bulletin 055 Page 3 of 10 March 2022 MINIM www.reliablesprinkler.com Model DH80 Dry Sprinkler with HB Escutcheon Figure 3 Ceiling Escutcheon 4" [102 mm] Min. Sprinkler Can 12" [305 mm] Max. Inlet Fitting 1-13/16"" �— System Tee [46mm] /„� l„�'lllIIIllhI��� _nr r, ti 5l8"[16 mm]I _. 3-1/2" [ ] "1 1I ILI II III I II 1111141 89 mm 1_-`---z, Dia. 21/2" Dia. [64 mm] Hole in Wall 1-1/4" 1-1/4" 32mm Nominal 055HB [32mm] [ ] Projection --► --.4 - 1/2"[13mm] Escutcheon Adjustment 1/2"[13 mm] Escutcheon—+.- 4- Nominal Escutcheon Position Adjustment —•1 "A"Dimension MODEL DH80 DRY HSW SPRINKLER, HB ESCUTCHEON "A" Dimension = 3-1/2" to 36" (90mm to 900mm) Finish Combinations:HB Escutcheon Sprinkler Escutcheon(2"j3) Bronze Chrome Chrome Chrome 8411110kWhite Polyester�1) White Polyester � I Black Polyester 1 Black Polyester 1, 110 Custom Color Polyester(') Custom Color Polyester Electroless Nickel PTFE(1) Stainless Steel Notes: 1. UL Listed as Corrosion Resistant. 2. Escutcheons do not carry corrosion resistant listings. 3. Base material is cold rolled steel unless noted. Bulletin 055 Page 4 of 10 March 2022 Rel.abl www.reliablesprinkler.com Model DH80 Dry Sprinkler with FP Escutcheon Figure 4 z Ceiling 1' , I _ Nom IN- Escutcheon 1 1/4" [32mm] Sprinkler Cup 4"[102mm]Min. System Tee 12"[305mm]Max. 111 Inlet Fitting _ski ,„moo= ii -a( IIIIIIL.,I1I I 111r��`�i 5/8"[16mm] 1■ k _ -1__.1 I [82mm] 2 5/8"Dia. [67mm] II osaFP Hole in Wall 1/4"[6mm] Escutcheon Adjustment 1/4"[6mm] - Nominal Position of Escutcheon Adjustment Escutcheon "A"Dimension DH80 DRY HSW SPRINKLER, FP RECESSED ESCUTCHEON "A" Dimension = 3-1/2" to 36" (90mm to 900mm) Note: Do not install the Model DH80 Dry Sprinkler with FP recessed escutcheon in locations where there is positive pressure in the cavity behind the sprinkler relative to the pressure at the sprinkler. Finish Combinations: FP Recessed Escutcheon Sprinklers'" Escutcheon(3)t41 Bronze Brass Chrome Chrome • - rNk ��}4t•f�, White Polyestert2i White Polyester I lYl4 Black Polyestert2i Black Polyester ,.1 Custom Color Polyester(2) Custom Color Polyester Electroless Nickel PTFE(2) Stainless Steel Notes: 1. Cup for FP Recessed is unfinished galvanized steel except electroless nickel PTFE sprinkler uses a stainless steel cup. 2. UL Listed as Corrosion Resistant. 3. Escutcheons do not carry corrosion resistant listings. 4. Base material is cold rolled steel unless noted. Bulletin 055 Page 5 of 10 March 2022 Rellabl www.reliablesprinkler.com Model DH80 Dry Sprinkler with SWC Cover Plate Figure 5 Ceil'.ng', e 1-9/16" [40mm] Sprinkler Cup 4"[102mm]Min System Tee 12"(305mm]Max Inlet Fitting // 5/8"[16mm] 7—r 3-7/32"Dia. _ [82mm] 2-5/8"[67mm]Dia. it Hole in Wall 055SWC Y _ 1/4"[6mm] "` Cover Plate Adjustment 1/4"[6mm] Nominal Position Cover Plate Adjustment of Cover Plate "A"Dimension— DH80 DRY HSW SPRINKLER, SWC CONCEALED COVER PLATE "A" Dimension = 3-1/2" to 36" (90mm to 900mm) Note: Do not install the Model DH80 Dry Sprinkler with SWC cover plate in locations where there is positive pressure in the cavity be- hind the sprinkler relative to the pressure at the sprinkler. Finish Combinations:SWC Concealed Cover Plate Sprinklertlt Cover Plate) White Polyester Chrome Bright r �.rS7 e� Chrome Dull = ' Bronze Bright Brass Unfinished Bronze Custom Color Notes: 1. Cup for SWC Concealed is unfinished galvanized steel. 2. Cover plates do not carry corrosion resistant listings. Bulletin 055 Page 6 of 10 Re March 2022 www.reliablesprinkler.com Figure 6 MINIMUM EXPOSED BARREL LENGTH WHEN CONNECTED TO WET PIPE SPRINKLER SYSTEM NOTE: STANDARD DRY PENDENT IS SHOWN, HOWEVER, MINIMUM EXPOSED BARREL LENGTH APPLIES TO ALL STYLES OF DRY SPRINKIERS CONNECTED TO A WET PIPE SYSTEM. WET PIPE EXPOSED BARREL AMBIENT AMBIENT TEMPERATURE TEMPERATURE ( ---10'I , n --_f_---r---m----i' EXPOSED TO 40F/4'C I SOF/10'C I 60F/16'C , II " NOTE TEE MAY BE IN ANY DISCHARGE END - --, I-—r- - -jlII - ORIENTATION FOR WET PIPE OF SPRINKLER• EXPOSED MINIMUM BARREL LENOTH•• I SYSTEMS. (F4CE OF FITTING TO TOP OF CEILING)•• •,7_-::AP L--, ii L__{1I - IN. (MM) IN. (MIN) IN. (MM) -'--1 --- I-zJ 407(4'C) 0 0 0 r 30F (-I'C) 0 0 0 Mill IF HUMIDITY AND TEMPERATURE DIFFERENTIAL OED DRY SPRINKLER. CONSIDER WRAPPING ON THEETXHE EXPOSED 20T (-TO) 4 (100) 0 0 BARREL WITH INSULATION. FOAM INSULATING 107(-12'C) 8(200) 1 (25) 0 TAPE OR EQUIVALENT. OF(-1B'C) 12(300) 3 (75) 0 MINIMUM (HEATED AREA) III SEAL THE CLEARANCE SPACE AROUND -10F(-23'C) 14(350) 4(100) 1 (25) EXPOSED LEAKAGE THE OFAIRRINTOER THEOPROOTED BARRELPROTECTED -207(-29'C) 14(350) 6 (150) 3 (75) LENGTH AREA AND CONSEQUENT AROUNDFORMATION THE FRRAME,E. WHICH DIMENSION CLEARANCE COULD INHIBIT OPERATOR OR CAUSE -30'F(-34'C) 16 (400) 6 (200) 4(100) HOLE PREMATURE OPERATION. SEE BELOW FOR -40F(-40'C) 18 (450) 8(200) 4(100) RECOMMENDED METHODS. -50'F(-46'C) 20 (500) 10(250) 6 (I50) _ -60F(-511c) 1 20 (soo) 10(250) 6 (150) • FOR AMBIENT TEMPERATURES EXPOSED TO THE DISCHARGE EEBEEEEEEI EIEBEEBEE INSIDE SURFACE OF END OF THE SPRINKLER THAT OCCUR BETWEEN -HE VALUES 4143113319311 I INSULATION. WALL. OR LISTED. USE THE NEXT COOLER TEMPERATURE EIMBEEE1E1E8E8333W CEILING •• THE MINIMUM EXPOSED BARREL LENGTH IS NOT THE SAME EEEM I AS THE -A' DIMENSION. THE MINIMUM EXPOSED BARREL - —_ LENGTH IS BASED ON A PROPERLY SEALED PENETRATION WITH A MAXIMUM WIND VELOCITY ON THE EXPOSED SPRINKLER OF al....111 30 MPH (48 KM/H). LONGER EXPOSED BARREL LENGTHS WILL THERMAL ESCUTCHEON HELP AVOID FREEZING OF THE WET PIPING WHERE HIGHER BARRIER ROW WIND VELOCITY IS EXPECTED. tl •• THE MINIMUM EXPOSED BARREL LENGTH IS MEASURED �I!, DISCHARGE END OF SPRINKLER FROM TIIE FACE OF THE FITTING TO THE INSIDE FACE OF THE INSULATION, WALL, OR CEILING LEADING TO THE COLD SPACE, WHICHEVER IS CLOSEST TO THE FITTING. PROTECTED (NON-COND,TIONED) AREA RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS (DRY SPRINKLER WITH STANDARD ESCUTCHEON SHOWN) SYSTEM PIPING SYSTEM PIPING t sT Fz i s1 lkr MA L tt- 15_ A l -ll1 _ r_zJ -1� r-tiJ_ _r --- 5 r =--- ul M„ (HEATED AREA) Mill(HEATED AREA) MINIMUM MINIMUM EXPOSED EXPOSED BARREL P, BARREL LENGTH DECKEC FLASHING Z INSIDE FACE \ [SEAL LENGTH (SEE ABOVE) RASCO N4003910 LASHING \\\\\ (SEE ABOVE) (RECOMMENDED) CLEARANCE HOLE a III _.... me ee INSULATED FREEZER, OR COOLER STRUCTURE I• — ! 1 1 i OR EXTERIOR FRAMING (PROTECTED AREA) II`Ylll� W COLDSPRINKLER OF (PROTECTED AREA) 1I111',I� IN DISCHARGE S RNKLER OF DISCHARGE END Y AR A r CON DRYOETI1 Bulletin 055 Page 7 of 10 T March 2022 1-r- www.reliablesprinkler.com Figure 7 *CAUTION* RELIABLE DRY SPRINKLERS MAY BE INSTALLED IN A LISTED CPVC SPRINKLER FITTING, ONLY UPON VERIFICATION THAT THE FITTING DOES NOT INTERFERE WITH THE SPRINKLER'S INLET. Do not install dry sprinklers with standard inlets into CPVC fittings that have an internal obstruction;this will damage the sprinkler,the fitting, or both. Short inlet("PL")versions of Reliable dry sprinklers are available that may or may not be compatible with fittings having internal obstructions in existing installations. Sprinklers with the short inlet("PL")should only be installed in CPVC fittings of wet-pipe systems. In all cases, verify sprinkler and fitting dimensions prior to installation to avoid interference. Internal Obstruction No Internal Obstruction Female Female Pipe I Pipe ✓� / Thread Thread �� A - CPVC Fitting with Internal Obstruction CPVC fitting No Internal Obstruction Shorter == Longer inn Inlet — Inlet Male Male Pipe —� Pipe Thread " Thread Ii Dry Sprinkler Dry Sprinkler Short Inlet ("PL") Standard Inlet BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION Bulletin 055 Page 8 of 10 March 2022 e— .a www.reliablesprinkler.com Installation (General) Note: Dry sprinklers connected to wet pipe systems must be installed as 1. The Model XLO2 installation wrench for FP Recessed indicated in Figure 6 and as required by NFPA 13 with the Exposed and SWC Concealed installations has a open side to Minimum Barrel Length located in a heated area. accommodate the sprinkler deflector and can only be inserted in one way(see Figure 8). Care must be taken not to Reliable Model DH80 dry sidewall sprinklers may be installed in damage the deflector during installation. ductile or malleable cast iron threaded tees,or CPVC tees and 2. Do not over-tighten sprinklers into fittings. It is recommended adapters upon verification that the sprinkler inlet fitting does not that Reliable dry sprinklers be installed using the wrench interfere with the interior of the fitting(see Figure 7). referenced in this bulletin.A pipe wrench may also be used to install dry sprinklers provided that it only engages the DO NOT install Reliable Model DH80 dry sidewall sprinklers into outer tube(steel pipe)of the assembly. Note that a pipe elbows or couplings,welded outlets, mechanical tees,or gasket wrench will impart a large amount of torque into the final sealed CPVC fittings. assembly.This torque will need to be matched or exceeded to remove the sprinkler at a later date.A leak free joint can DH80 HSW with Standard Escutcheon normally be obtained by installing the sprinkler to a minimum Cut a 2-1/8"(54mm)diameter hole in the wall as shown in Fig. torque of 22 ft-lb(30 N-m)after applying an appropriate 2.Apply a PTFE based sealant to the sprinkler threads before thread sealant. installing into the fitting. Use the Model F3R installation wrench 3. Glass bulb sprinklers have orange bulb protectors to (see Fig.8)on the square boss to tighten the sprinkler until minimize bulb damage during shipping, handling, and it is secured in the sprinkler fitting. Installation is completed installation. Reliable installation wrenches are designed to by removing the orange glass bulb protector and sliding the install sprinklers while bulb protectors are in place. REMOVE escutcheon over the finished sleeve until tight to the finished THE PROTECTORS AT THE TIME THE SPRINKLER SYSTEM surface. IS PLACED INTO SERVICE. Removal of the protectors before this time may leave the glass bulb vulnerable to damage. DH80 HSW with HB Escutcheon Remove protectors by undoing the clasp by hand. DO NOT Cut a 2-1/2"(64mm)diameter hole in the wall as shown in Fig. USE TOOLS TO REMOVE THE PROTECTORS. 3.Apply a PTFE based sealant to the sprinkler threads before 4. Do not remove the wax fillet in the gap between the cup that installing into the fitting. Use the Model F3R installation wrench supports the bulb and the wrenching boss. (see Fig. 8)on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and sliding the skirt over the finished sleeve until tight to the finished suface. XLO2 Installation Procedure Figure 8 DH80 HSW with FP Recessed Escutcheon Cut a 2-5/8" (67mm)diameter hole in the wall as shown in Fig. r 4.Apply a PTFE based sealant to the sprinkler threads before 1011 installing into the fitting. Use the Model F3R installation wrench (see Fig.8)on the square boss to tighten the sprinkler until At) it is secured in the sprinkler fitting. Installation is completed Step 1 by removing the orange glass bulb protector and pushing (or threading)the FP escutcheon into the threaded cup. Final adjustment is made by turning the FP escutcheon clockwise until the flange makes full contact with the wall surface. ;,, ����• ;,�" E. . DH80 HSW SWC Concealed Cover Plate Cut a 2-5/8"(67mm)diameter hole in the wall as shown in Fig. 5.Apply a PTFE based sealant to the sprinkler threads before installing into the fitting. Use the Model F3R installation wrench Step 2 (see Fig.8)on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting. Installation is completed by removing the orange glass bulb protector and pushing (or • threading)the SWC cover plate into the threaded cup. Final adjustment is made by turning the cover plate clockwise until the `) ' cover plate flange makes full contact with the finished surface. *" Step 3 E Bulletin 055 Page 9 of 10 March 2022 Reliable www.reliablesprinkler.com Wrench Options 110 F3R Wrench(Standard&HB trims) XLO2 Wrench(FP recessed and SWC trims) Maintenance Ordering Information Reliable Model DH80 series sprinklers should be inspected and Specify: the sprinkler system maintained in accordance with NFPA 25,as well as the requirements of any Authorities Having Jurisdiction. Sprinkler Type Prior to installation,sprinklers should remain in the original • Model DH80 Dry Extended Coverage Horizontal cartons and packaging until used.This will minimize the potential Sidewall Sprinkler for damage to sprinklers that could cause improper operation or non-operation. Trim Style • Standard Escutcheon Do not clean sprinklers with soap and water, ammonia liquid or • HB Escutcheon any other cleaning fluids. Remove dust by gentle vacuuming • FP Recessed Esctucheon without touching the sprinkler. • SWC Cover Plate Replace any sprinkler which has been painted(other than factory Temperature Rating applied).A stock of spare sprinklers should be maintained to • 155°F(68°C) allow quick replacement of damaged or operated sprinklers. • 175°F(79°C) Failure to properly maintain sprinklers may result in inadvertent • 200°F(93°C) operation or non-operation during a fire event. Finish Guarantee • See available combinations(depending on trim style) on pages 3-6 For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions,visit www.reliablesprinkler.com. Length • "A" Dimension (face of fitting to finished wall surface, Patents in 1/4" [6mm] increments) US Patent No. 7,841,418 Installation Wrench • Model F3R(Standard&HB trims) •Model XLO2 (FP Recessed&SWC trims) 0 0) rn rn Bulletin 055 Page 10 of 10 °' March 2022 Reliably www.reliablesprinkler.com a Bulletin 621 March 2022 Model CR Commercial Riser Re a ® 1 1/2"throughcULus Sizes Listed, Ap proved mm)0 roved pp Features • Cast stainless steel body for 1-1/2"models and 2"threaded model • Schedule 10 welded body for 2"-8" grooved versions • Optional schedule 40 manifold for 2" -4" sizes .., 441, • Approved for vertical or horizontal installation t Product Description The Reliable Model CR Commercial Riser arrives factory assembled with water flow switch, pressure gauge, and main drain for a cost-effective system riser or floor control assembly. The Model CR is cULus listed(VEOY.EX5980)and FM approved as a unit.The main drain is available with a ball valve or Reliable 3" (80mm)welded Commercial Riser Test and Drain valve,which is available with a wide selection of w/175psi Pressure Relief Kit and Test&Drain Valve(K5.6) test orifice K-factor choices.An optional pressure relief valve kit, available in 175, 185, 210, 260,and 310 psi(12, 13, 14, 18,and 21 bar)rating, is also available. Model CR Commercial Riser Table A K-Factor for Valve Size End Connections Pressure Material End-to-End Drain Size Optional Test Rating Take Out and Drain Valve* Threaded 8-1/4'' (NPT or BSPT) Cast Stainless (210mm) 1" (25mm) 1-1/2"(40mm) Grooved (250 psi) Cast Stainless (241/mm) 1" (25mm) 2.8(40) 17.2 bar Threaded 8-1/4" 4.2(60) 2"(50mm) (NPT or BSPT) Cast Stainless 1"(25mm) 5.6(80) (210mm) 2"(50mm) Grooved S10, S40 Steel 13 1"(25mm) (330mm) 2-1/2"(65mm) Grooved S10, S40 Steel 13" 1-1/4" 2.8(40) (330mm) (32mm) 4.2(60) 5.6(80) 3"(80mm) Grooved S10, S40 Steel 13" 1-1/4" 8.0(115) 300 psi (330mm) (32mm) 11.2(160) (20.7 bar) 13" 4"(100mm) Grooved S10,S40 Steel (330mm) 2"(50mm) 2.8(40) 4.2(60) 6"(150mm) Grooved S10 Steel 13 2" (50mm) 5.6(80) (330mm) 8.0(115), 13" 11.2(160) 8"(200mm) Grooved S10 Steel (330mm) 2" (50mm) 16.8(240) *Note:K-factor must be equal to or less than the K-factor of the smallest K-factor installed on the sprinkler system. For sprinkler sys- tems where the smallest K-factor sprinkler on the system is greater than the largest available valve K-factor, use any valve K-factor that will provide a minimum flow of 10gpm (38 Ipm)as required to operate a UL Listed Waterflow Switch. www reliablesprin kler.com Model CR Commercial Riser Threaded End Assemblies(1-1/2" [40mm]&2"[50mm]) Figure 1 B— PRESSURE GAUGE D Threaded End Basic Assembly w/ Table B Pressure Relief Valve 2PRESSURE 3-WAY End Manifold A B C D E Weigh VALVE [,_III RELIEF 11 I� i KIT Connection in in in Ibs Pipe Size in in in(mm) (mm) (mm) (mm) (mm) (mm) (kg) ,Ifi: a h, 1-1/2 12- 1!8 10-1/2 3 5-1/2 8-1/4 8.3 A - Oa Nil E C 111 Threaded (40) (308) (267) (80) (140) (210) (3.8) (TAKE OUT) °.� r iEi Ends ��� (See Fg.1) 2 12- 10-3/4 3-1/4 5-3/4 8-1/4 9.1 (50) 1B (273) (83) (146) (210) (4.1) miniaol��� � •1= (308) i 1 ':I -'�m / I I BALL WATERFLOWJ MANIFOLD f--C--I VALVE DETECTOR BODY (DRAIN CONNECTION) BASIC ASSEMBLY(2"[50MM]VERSION SHOWN) WITH OPTIONAL PRESSURE RELIEF KIT E21Fco:c B PRESSURE HANDLE IN TEST POSITION GAUGE -D Threaded End w/Test&Drain Valve and Pressure Relief KitsMIME 3-WAY ILl ,y p �II';.] End Manifold A B C D E Weight VALVE / Pipe Size in in in in in lbs �,� Connection ��� in(mm) (mm) (mm) (mm) (mm) (mm) (kg) �i �� A ,�i- 'I� (i �m[`112- , ■ 2 14-1/4 3 5-1/2 8-1/4 8.3 E r�.��� � 1/8 01 �� \� lig ThEnddeds (40) (308) (� (80) (140) (210) (3.8) (TAKE OUT) prip =. (See Fig.1) 2 12 14-12 3-1/4 5-3/4 8-1/4 9.1 ID (50) 1/8 (368) (83) (146) (210) (4.1) No nnw TEST/DRAIN (308) VALVE CONNECTION) WATERFLOW DETECTOR MANIFOLD C BODY BASIC ASSEMBLY (2°[50MM]VERSION SHOWN) WITH TEST AND DRAIN VALVE &OPTIONAL PRESSURE RELIEF KIT (TEST MID DRAIN SHOWN IN TEST POSITION) Bulletin 621 Page 2 of 5 March 2022 Re abl www.reliablesprinklercom Model CR Commercial Riser Grooved End Assemblies(2" [50mm]-8" [200mm]) Figure 2 Grooved End Basic Assembly w/ B Pressure Relief Valve Table D PRESSURE D End Manifold A B C D E Weight PRESSURE Connection Pipe Size in in in in in Ibs RE110 in(mm) (mm) (mm) (mm) (mm) (mm) (kg) KIT 0 IM°111j REDUCING 1-1/2 13-12 10-1/2 3 5-1/2 9-1/2 8.3 TEE \ �ii(Mi (40) (343) (267) (76) (140) (241) (3.8) VALVE •.iii 2 15-1/4 14-1/2 5-1/4 6 13 10.7 A 3-WAY E (50) (387) (368) (133) (152) (330) (4.9) (TAKE OU l 2-1/2 15-1/4 5 6-3/4 6-1/4 13 12.9 ���� %�� (�..��a� (65) (387) (381) (171) (159) (330) (5.9) WMTesLDw I. �,■F- •�� _ Grooved DeEcroR fiiii� '�,'� �' „; Ends 3 15-1/4 16-1/4 7 6-1/2 13 17.6 (see Fg.2) (80) (387) (413) (178) (165) (330) (8.0) MANIFOLDBALL 4 15-1/4 19 8-1/4 7 13 21.3 Dwr OKAIN VALVE (80) (387) (483) (210) (178) (330) (9.7) C COMNEC11ON 6 15-1/4 21-1/2 9-1/4 8 13 26.3 BASIC ASSEMBLY[3'[80MM]VERSION SHOWN' (150) (387) (546) (235) (203) (330) 11. WITH OPTIONAL PRESSURE RELIEF KIT ( 9J 8 15-1/4 23 10-1/4 9 13 31.0 (200) (387) (584) (260) (229) (330) (14.1) B HANDLE M TEST P091A)N B1_ Grooved End w/Test&Drain Valve and Pressure Relief Kits Table E III(i.=i End Manifold A B C D E Weight PRESSURE _ ��.�1 Connection Pipe Size in inin in in lbs l yea■) in (mm) (mm) (mm) (mm) (mm) (mm) (kg) A 3-WAY 1■II�III`� 125NTa 1-1/2 13-12 11-1/2 3-1/2 5-3/4 9-1/2 8.3 .h� E (40) (343) (292) (89) (146) (241) (3.8) �I'� (TAKE Olin '�.• 2 15-1/4 16 5-1/4 6 13 10.7 wATERrtav �� 50 387) 406 133 152 33D DEfEDTOR '�� 1 \iVALVEDAMN ( J ( ,/ ( ) ( J ( J ( ) (4.9) 4 UMVALVE(SZAPi 1�"' ON"EG ONI 2-1/2 15-1/4 16-12 6-3/4 6-1/4 13 12.9 em.= (65) (387) (419) (171) (159) (330) (5.9) IMNsBOOT __ GEds d 3 15-1/4 17-1/4 7 6-1/2 13 17.6 c (see Fig.2) (80) (387) (438) (178) (165) (330) (8.0) BASIC ASSEMBLY(4'[100MM]VERSION SHOWN 4 15-1/4 26-12 8-1/4 7 13 21.3 WITH TEST AND DRAIN VALVE (80) (387) (521) (210) (178) (330) (9.7) &OPTIONAL PRESSURE RELIEF KIT REST AND DRAIN MOM III REM'POSMO 6 15-1/4 23 9-1/4 8 13 26.3 (150) (387) (584) (235) (203) (330) (11.9) 8 15-1/4 24-12 10-1/4 9 13 31.0 Notes: (200) (387) (622) (260) (229) (330) (14.1) 1. 1-1/2"grooved version will be cast in stainless steel, 2. 1-1/2"and 2" models will have threaded test and drain valve. Bulletin 621 Page 3 of 5 March 2022 ee■ gabra www.reliablesprinkler.com Installation Guarantee The Model CR Commercial Riser shall be installed in accordance For Reliable Automatic Sprinkler, Co., Inc.guarantee, terms, and with NFPA 13,"Standard for the Installation of Sprinkler Systems," conditions,visit www.reliablesprinkler.com. as well as the requirements of any authorities having jurisdiction. When installed vertically,the direction of flow shall be up through Ordering Information the assembly. For horizontal installations,the water flow indicator must be located to the top and drain opening to the bottom.Failure Specify: to follow installation instructions may void the warranty and/or listing of the valve.Verify compatibility of the Model CR Commercial Riser 1. Reliable Model CR Commercial Riser materials with the water supply and the environment where the valve 2. Size will be installed prior to installation. 3. End Connections 4. (Optional)Schedule 40 (2"through 4"grooved end only) Maintenance 5. Drain Option(Ball valve or Test and Drain valve) 6. Test orifice K-factor(if ordering Test and Drain valve) The owner is responsible for maintaining the fire protection system 7. (Optional) Pressure Relief Valve Kit in proper operating condition.Any system maintenance or testing that involves placing a system out of service may eliminate the fire protection that is provided by the fire protection system.Notify any Notes: required authorities having jurisdiction and implement appropriate 1. All Model CR Commercial Riser Assemblies come with a 300 precautions prior to proceeding. psi(20.7 bar) UL Listed and FM Approved pressure gauge for 175 psi(12.1 bar)applications. If the Model CR Corn- The Reliable Model CR Commercial Riser shall periodically be given mercial Riser Assembly is to be installed in a higher pressure a thorough inspection and test.NFPA 25,"Inspection,Testing and application, please purchase a 600 psi (41.4 bar) (P/N Maintenance of Water Based Fire Protection Systems,"provides 98248005) pressure gauge.This gauge may or may not be minimum maintenance requirements.Replace any components UL Listed and/or FM Approved at the time of purchase. found to be corroded,damaged,worn or non-operable.Increase 2. Unless specified at the time of ordering, pressure relief kits the frequency of inspections when the valve is exposed to corrosive are installed at the factory. conditions or chemicals that could impact materials and/or operation of the assembly. Note:The water flow switch for the 1-1/2"and 2"cast stainless steel manifold uses a proprietary paddle. This paddle is only available for purchase from Reliable.When replacing water flow switch,order part number 96556923. Bulletin 621 Page 4 of 5 March 2022 el able www.reliablesprinkler.com Commercial Riser Ordering Information Part Number Figure 3 6A XX OC P YY Z I I I I I Riser Manifold Option Pressure Relief Valve Size&End Connections Drain Valve/K-Factor • XX YY •ti'.. 04= 1-1/2" BSPT Female SS 00= 1" Ball Valve 0 = None 05= 1-/2"Grooved SS 03= 1" RASCO T&D Valve K2.8 1 = 175 psi (12.1 bar) 07=2" BSPT Female SS 04= 1" RASCO T&D Valve K4.2 2= 185 psi (12.8 bar) 08= 1-1/2"NPT Female SS 05= 1" RASCO T&D Valve K5.6 3=210 psi (14.5 bar) 09=2" NPT Female SS 4=260 psi (17.9 bar) 10=2"Grooved SCH10 5=310 psi(21.4 bar) 11 =2"Grooved SCH40 12=2-1/2"Grooved SCH10 01 = 1-1/4" Ball Valve 13=2-1/2"Grooved SCH40 26= 1-1/4" RASCO T&D Valve K2.8 14=3"Grooved SCH10 06= 1-1/4" RASCO T&D Valve K4.2 15=3"Grooved SCH40 07= 1-1/4" RASCO T&D Valve K5.6 08= 1-1/4" RASCO T&D Valve K8.0 09= 1-1/4" RASCO T&D Valve K11.2 16=4"Grooved SCH10 02=2" Ball Valve 17 =4"Grooved SCH40 27=2" RASCO T&D Valve K2.8 18=6"Grooved SCH10 28=2"RASCO T&D Valve K4.2 19 =8"Grooved SCH10 10=2" RASCO T&D Valve K5.6 11 =2" RASCO T&D Valve K8.0 12=2" RASCO T&D Valve K11.2 13 =2" RASCO T&D Valve K16.8 Notes: 1. 1-1/2"and 2"manifolds have a 1"threaded drain outlet. 2. 2-1/2"and 3"manifolds have a 1-1/4"grooved outlet for Test&Drain valve or a 1-1/4"threaded outlet for ball valve drain. 3. 4",6",and 8" manifolds have a 2"grooved outlet for Test&Drain valve or 2"threaded outlet for ball valve drain M 0 r` rn rn m Bulletin 621 Page 5 of 5 March 2022 Mira www.reliablesprinklercom Bulletin 360 March 2022 ® Model FX Dry Pipe Valve 2" (50mm), 2 m 6" 3"(165 m), 4" 2"(100mm),(65 ) (150mm), 165m), cUlus Listed, FM Approved Features • Lightweight ductile iron body with compact trim • External reset reduces setup and commissioning time `i • Does not require priming water Product Description The Reliable Model FX Dry Pipe Valve is a differential-principle, externally resettable valve designed for use as a primary control 1, valve in a dry pipe system.The valve clapper is held in the set position by pneumatic pressure acting on a larger surface area than that of the incoming water pressure. Release of pneumatic pressure from the system allows the dry pipe valve to open.The Model FX valve is available with grooved end,flanged end,or !r` flange x grooved end connections(see Table A). When required, all sizes of the Model FX valve may be equipped , with the Reliable Model B1 Accelerator(PN 650120001A;ordered separately).The accelerator is a normally closed valve that opens upon a predetermined rate of air or nitrogen pressure loss. When the accelerator opens,air or nitrogen pressure is directed to the intermediate chamber of the Model FX valve, hastening the valve trip time. Please refer to Reliable Technical Bulletin 323 for further Note: Pressure switches(low air and flow alarm)provided with information. fully assembled valves only. Order separately with loose and segmented trim. Model FX Dry Pipe Valve Technical Data Table A Fully Assembled Weight Approximate Shipping Weight for Rated Pressure Listings and Valve Size End Connection (w/o Control Valve) Valve Fully Assembled with Trim Ibs(kg) Ibs(kg) psi(bar) Approvals 2"(50mm) Groove/Groove 42(19) 82(37) 250(17.2) 2-1/2" (65mm) Groove/Groove 55(25) 115(52) 76mm Groove/Groove 55(25) 120(54) 3"(80mm) Groove/Groove 56(25) 120(54) Groove/Groove 78(35) 155(70) cULus 4"(100mm) Flange/Groove 90(41) 167(76) FM 300(20.7) Flange/Flange 102(46) 179(81) Groove/Groove 127(58) 234(106) 6"(150mm) Flange/Groove 136(62) 252(114) Flange/Flange 163(74) 270(122) 165mm Groove/Groove 127(58) 234(106) Notes: 1. Grooved ends per ANSI/AWWA C606;flanged ends per ASME 616.5 Class 150, BS10 BS-E,or ISO 7005-2 PN16(specify). 2. Valves are intended to be installed on systems where the pressure does not exceed the working capabilities of the end configurations. 3. Approximate shipping weight given for fully assembled valve and trim, including control valve and accelerator. www.rel iablesprinkler.com Model FX Dry Pipe Valve Technical Specifications End Connections Pressure Rating:See Table A See Table A ;, > Installation Orientation .«w Material Specifications Vertical(Up Through Valve) Body&Cover:Ductile Iron,painted Clapper Stainless Steel Approvals "* Seat:EPDM Rubber/Aluminum cULus Listed Trim:Galvanized Steel FM Approved i MT i" • •' Model FX Dry Pipe Valve Components and Dimensions Figure 1 E II (p) Notes: L J 1. Valve is shown with optional Model B1 Accelerator , 4117,11164k 2. Pressure switches(low air and flow -- -- alarm)provided with fully assembled TO valves only.Order separately with loose and segmented trim. \ImI\ •.IcS F d Illy II Mil 1/41) a � Y- ■ T— its f.-.i.I .7=5 — I',1 ti A(FX) ( cjo�""'•r isFA Ilip l� II i p • 'y 17 Inagigniii 7�i'. Imo'�j" lI� B(BFY) �;�i �Ii ��1Lil�D 3y� I, im 'I G D— C 360FG01A I►--H I - J . Model FX Dry Pipe Valve Dimensions-in. (mm) Table B Valve Size A B C D E F G H I J 2"(50mm) 10 4-1/8 10 7 8-1/4 41 1-3/4 7-1/4 9-5/8 21-3/8 (254) (105) (254) (178) (210) (1041) (44) (184) (244) (543) 2-1/2"(65mm), 3" 12-1/4 3-3/4 10-1/4 7-3/8 8-1/4 43-3/4 5-7/8 8-1/4 10-1/8 22 (80mm),&76mm (311) (96) (260) (187) (210) (1111) (149) (210) (257) (559) 4"(100mm) 13-3/4 4-1/2 10-7/8 7-1/2 8-1/4 45-5/8 4-7/8 9-5/8 10-3/4 24-1/2 (349) (114) (276) (191) (210) (1159) (124) (244) (273) (622) 6"(150mm), 165mm 16 5-1/4 12-1/2 7-1/2 8-1/4 46-3/4 4-5/8 11-1/2 12 30-1/2 (406) (133) (318) (191) (210) (1187) (118) (292) (305) (775) Note: Dimension A(body take-out)is same for all end configurations. Dimension B(control valve)is not applicable to 76mm and 165mm valves as well as flanged valves. Bulletin 360 Page 2 of 6 March 2022 'Renabld www.reliablesprinkler.com Model FX Dry Pipe Valve Section View Figure 2 To System To System ♦ t Air/Nitrogen Inlet J Latch ; Clapper 1 l, Air/Water Seat �,���. �� External,` ' _ „ , \,� Reset , Li.... N\ Main —�� - : 1 0 1 3 r" Hinged ¢ i Drainer �� Alarm Outlet • 1 -- j I It Water Supply Water Supply Model FX Dry Valve Model FX Dry Valve Set Condition Tripped Condition Model FX Dry Pipe Valve Components Figure 3 aiiiilb Optional Accelerator =1IP. Notes: �1mr9 (See Bulletin u323) `�. 1. Valve is shown with optional Model B1 Ake__l� �_ Accelerator 2. Pressure switches(low air and flow alarm) provided with fully assembled valves only. Order separately with loose and segmented trim. System Pressure Gauge ri� 111111,111 u High/Low Supervisory '�� Pressure Switch inih u II �! Accelerator Isolation :: I.' \ .I Valves ■ I .�.�. i Check Valve r.C' 4111174 _4 Alr/Nitrogen Inlet&Control S,,-°'�)�r�)\1)�� —,._r,;c —Valve y/��� I ••N'� �O. water Flow Alarm ��ijll>���� Cr�• Pressure Switch ./.External Reset '� /^ �"®�''.I. �fr." 'R�II,I MAWi 01. b ICi..p 7,,F1/ Condensate ,I■I , �"r rmn^'"" v""/��_ Drain Valve i�Ir1�lT ® °°• Me Outlet ,I �• • i��'�.�.�� Mechanical Alarm — r` Supply Pressure Gauge �—�- q.� _ i. r li g ios1 ern:.--- 1Mlr. ��� s:IS_)I-_ I �ti•'d'���;1t�� *k Alarm Line Ball Drip Valve v�ll — Num ' � ?" Intermediate Chamber ■a3 `�--7 .1—I Main Drain Valve `'/ Ball Drip Valve i ,[�j In:IMF Aff � 1.. r 1 �� 't �� Main Control Valve omm Alarm Test Valve (Normally closed) 360FG03A Bulletin 360 ..e Page 3 of 6 March 2022 Rel.ablC www.reliablesprinkler.com Operation The valve and trim kit have been tested,approved and listed in accordance with UL and FM standards. Hydrostatically testing The Reliable Model FX Dry Pipe Valve is shown in both the closed the valve and trim to pressures higher than their rating is limited and open position in Figure 2.The upper surface area of the to the hydrostatic test as referenced by NFPA 13. clapper is approximately six times larger than the surface area of the bottom of the clapper that is exposed to the water supply Normal operation and hydrostatic testing do not address the in the set position. In the closed position, pneumatic pressure possibility of a water hammer which may damage the valve.A acts on the larger upper surface of the clapper while water water hammer can create pressure more than the rated pressure pressure acts on the smaller lower surface area. Because of this of the equipment and should be avoided by all necessary means. surface area differential, one psi of pneumatic pressure can offset Water hammer can occur from(but is not limited to)improper approximately six psi of water pressure. Table C provides the fire pump settings, underground construction work,or improper appropriate pneumatic pressure to water pressure ratio. venting of trapped air in piping. When a sprinkler operates,the upward force of the water Friction Loss(Equivalent Length of pressure acting beneath the clapper overcomes the reduced Schedule 40 Pipe) Table D pneumatic pressure and allows the clapper to open.Water then flows through the Model FX Dry Pipe Valve into the system piping Size C= 100 C=120 Cv and into the alarm outlet activating the alarm device(s). Once ft(m) ft(m) Value the clapper has opened, the lever acts as a latch preventing the 2" (50mm) 7.2(2.2) 10.0 (3.0) 99 clapper from returning to the closed position until manually reset. 2-1/2"(65mm), 76mm 8.1 (2.5) 11.4(3.5) 170 3" (80mm) 9.5(2.9) 13.2 (4.0) 262 Pneumatic Pressure Requirement Table C 4" (100mm) 16.7 (5.1) 23.5(7.2) 396 Water Pressure Pneumatic Pressure 6"(150mm), 165mm 26.4 (8.0) 37(11.3) 861 psi(bar) psi(bar) Maximum Not Less Than Not More Than Model FX Dry Pipe Valve Set Up Procedure 20(1.37) 10(0.68) 20(1.37) (Reference Figure 2) 50(3.45) 15(1.03) 25(1.72) 75(5.17) 20(1.37) 30(2.06) 1. Close the Main Control Valve and close the Air/Nitrogen Control Valve. 100(6.89) 25(1.72) 35(2.41) 2. Open the Main Drain Valve and drain the system. 125(8.62) 30(2.06) 40(2.75) 3. Open all drain valves and vents at low points throughout the 150(10.34) 35(2.41) 45(3.10) system,closing them when flow of water has stopped. 4. Inspect and replace any necessary portions of the sprinkler 175(12.07) 40(2.75) 50(3.45) system subjected to fire conditions. 200(13.79) 45(3.10) 55(3.79) 5. Push in the plunger of the Intermediate Chamber Ball Drip Valve and the Alarm Line Ball Drip Valve to force the ball 225(15.51) 50(3.45) 60(4.14) from its seat to drain any water in the lines. 250(17.24) 55(3.79) 65(4.48) 6. When standing in front of the valve, locate the External Reset 275(18.96) 60(4.14) 70(4.83) on the left side of the dry valve body. Push in on the plunger in the center of the External Reset until you hear a distinct 300(20.68) 65(4.48) 75(5.17) clicking noise indicating that the clapper has closed. A tool, such as a screwdriver, may be needed to press the External Installation Reset plunger. 7. Open the Air/Nitrogen Control Valve and rapidly apply The Model FX Dry Pipe Valve shall be installed in accordance with compressed air or nitrogen into the Model FX Dry Pipe Valve NFPA 13, "Standard for the Installation of Sprinkler Systems," system until the pressure conforms to the level indicated in as well as the requirements of any authorities having jurisdiction. Table C, as indicated on the System Pressure Gauge. Set the The direction of flow shall be up through the assembly. Failure to air or nitrogen supply to automatic operation. follow installation instructions may void the warranty and/or listing 8. Partially open the Main Drain Valve. of the valve.Verify compatibility of the Model FX Dry Pipe Valve 9. Slightly open the Main Control Valve until water begins to materials with the water supply and the environment where the flow through the Main Drain Valve. valve will be installed prior to installation. 10. Once water begins to flow through the Main Drain Valve, slowly close the Main Drain Valve. The Model FX Dry Pipe Valve must be installed in a readily visible 11. If installed, reset the Model B1 Accelerator per Reliable Tech- and accessible location where a minimum temperature of 40°F nical Bulletin 323 and open the Accelerator Isolation Valves. (4°C)or above must be maintained. Heat tracing of the Model FX 12. Observe if water leaks through the Intermediate Chamber Dry Pipe Valve and trim is not permitted. Heat tracing can result Ball Drip Valve into the closed drain. If no leak occurs,the in the formation of hardened mineral deposits that can prevent dry pipe valve clapper is sealed. proper operation of the dry pipe valve. 13. Slowly open the Main Control Valve.Verify that the Main Control Valve is fully open and properly monitored. Bulletin 360 �e1 Page 4 of 6 March 2022 www.reliablesprinkler.com Alarm Test Guarantee 1. Notify the owner and monitoring company that testing is For Reliable Automatic Sprinkler, Co., Inc. guarantee, terms, and being performed on the system. conditions,visit www.reliablesprinkler.com. 2. Open the Alarm Test Valve. 3. Verify that pressure alarm switch has activated, and signal has been reported to the fire alarm system. Ordering Information 4. Close the Alarm Test Valve. 5. Push in the plunger of the Alarm Line Ball Drip Valve to force the ball from its seat to relieve pressure and drain any water Specify: in the line. • Model FX Dry Pipe Valve When testing is complete, notify the owner and monitoring corn- • Size pany that the system has been returned to service. • End Connections Maintenance • Trim* -Fully assembled with control valve The owner is responsible for maintaining the fire protection -Fully assembled without control valve system in proper operating condition.Any system maintenance or -Segmented trim(control valve not included) testing that involves placing a system out of service may eliminate -Loose trim (control valve not included) the fire protection that is provided by the fire protection system. • (Optional)Model B1 Accelerator(PN 650120001A) Notify any required authorities having jurisdiction and implement appropriate precautions prior to proceeding. *Note: Low pressure switch(PN 6990006381) and alarm pressure switch(PN 6990006382)are included with fully The Reliable Model FX Dry Pipe Valve shall periodically be given a assembled trims only. Order separately when selecting thorough inspection and test. NFPA 25, "Inspection,Testing and segmented or loose trim. Maintenance of Water Based Fire Protection Systems,"provides minimum maintenance requirements. Replace any components found to be corroded,damaged,worn or non-operable. Increase the frequency of inspections when the valve is exposed to Service Kits corrosive conditions or chemicals that could impact materials and/or operation of the assembly. Service kits are available for routine servicing of the valve(refer- ence assembly drawings on website).Service kits for the Model Excess water may settle above the valve clapper following FX Dry Pipe Valve include the following components: hydrostatic testing,system activation, or as a result of condensation. To remove excess water from the system: • Seal Assembly(item 4) • Cover Gasket(item 5) 1. Notify the owner and monitoring company that maintenance • Grease(item 17) is being performed on the system. 2. Close the Main Control Valve and close the Air/Nitrogen Note: Seat and seal is an integral unit. Replacement requires the Control Valve. appropriate Seat Installation Wrench. 3. If an Accelerator is present,close the Accelerator Isolation Valves. 4. Open the Main Drain Valve. • 2"Model FX Seat Wrench: PN 6881702000 5. Open the Condensate Drain Valve on the left rear of the • 2-1/2"and 3"Model FX Seat Wrench: PN 6881703000 dry pipe valve body until all water has drained.Close • 4" Model FX Seat Wrench: PN 6881704000 Condensate Drain Valve immediately when the flow of water • 6" Model FX Seat Wrench: PN 6881706000 has stopped. 6. Open the Air/Nitrogen Control Valve and allow pneumatic pressure to return to normal(refer to Table C). Set pneumatic supply to automatic operation. 7. If an Accelerator was isolated in step three,open the Accelerator Isolation Valves. 8. Open the Main Control Valve until water begins to flow through the Main Drain Valve. 9. Slowly close the Main Drain Valve. 10. Fully open the Main Control Valve.Verify that the Main Con- trol Valve is fully open and properly monitored. 11. Notify the owner and monitoring company that the system has been returned to service. Bulletin 360 Page r.of 6 !• March 2022 www.reliablesprinkler.com Model FX Fully Assembled Part Number Figure 4 65080 X Y Z 00 L Valve Size End Connection Trim A Y z 2=2"(50mmp 7=Groove/Groove 0=W/O Control Valve,W/O Accelerator 1 =2-1/2"(65mm)" 8=Flange/Groove,Class 150 1 =W/Control Valve,W/O Accelerator" 7=76mm* 9=Flange/Groove, BS-E 2=W/2 Control Valves,W/O Accelerator` 3=3"(80mm)* A=Flange/Groove,PN16 3=W/O Control Valve,W/Accelerator 4=4"(100mm) B=Flange/Flange,Class 150 4=W/Control Valve,W/Accelerator* 6=6"(150mm) C=Flange/Flange, BS-E 5=W/2 Control Valves,W/Accelerator* 5= 165mm* E=Flange/Flange,PN 16 *Note:Available only with Groove/Groove connections Model FX Valve Only(No Trim) Part Number Figure 5 Weight(Valve Only) Figure 6 End Connection 61010 XX 60 Y Size Ibs(kg) GRV/GRV FLG/GRV FLG/FLG 2"(50mm) 22(10) N/A N/A 2-1/2"(65mm) 34(16) N/A N/A Valve Size End Connection &76 mm XX Y 3"(80mm) 35(15) N/A N/A 20=2"(50mm)" 7-Groove/Groove 4"(100mm) 52(24) 64(29) 76(35) 25=2-1/2"(65mm)* 8=Flange/Groove,Class 150 76=76mm" 9=Flange/Groove,BS-E 6"(150mm) 101 (46) 119(54) 137(62) 30=3"(80mm)* A=Flange/Groove,PN16 165mm 101 (46) N/A N/A 40=4"(100mm) B=Flange/Flange,Class 150 60=6"(150mm) C=Flange/Flange,BS-E 65=165mm* E=Flange/Flange,PN 16 *Note:Available only with Groove/Groove connections Model FX Trim Only Part Number Figure 7 Weight(Trim Only) Figure 8 Trim Part Numbers Loose Trim Segementally Valve Size Size lbs(kg) Assembled Trim Loose Segmentally lbs(kg) Assembled 2"(50mm) 20(9) 23(10) 2"(50mm) 6508000001 65080000011 2-1/2"(65mm), 2-1/2"(65mm),76mm, 6508000002 65080000012 76mm,&3"(80mm) 21 (10) 25(11) &3"(80mm) 4"(100mm),6" 4"(100mm),6" 26(12) 30(14) (150mm),165mm 6508000003 65080000013 (150mm),& 165mm rn U) 0 rn rn rn rn rn 2 Bulletin 360 www.reliablesprinkler.com 6 of 6 March 2022 www.reliablesprinkler.com Bulletin 831 April 2021 ® Model BFG-300 Supervised Re i a e Butterfly Valve Grooved cULus Listed, FM Approved Product Description The Reliable Model BFG-300 Supervised Butterfly valves are cULus Listed and FM Approved for fire protection systems. Reliable Supervised Butterfly Valves valves have AWWA C606 grooved end connections.They are available in 2-1/2"(65mm), 3"(76mm),4"(100mm),6" (150mm),and 8"(203mm)nominal sizes.The valves are listed for 300 psi(20.7 bar)working pressure.The maximum working temperature for the valves is 250°F(120°C). Maintenance 411;11LI The owner is responsible for maintaining the fire protection Supervised Grooved Butterfly Supervised Grooved Butterfly system in proper operating condition.Any system maintenance Valve-Supervised Open Valve-Supervised Closed or testing that involves placing a control valve out of service will eliminate the fire protection that is provided by the fire protection system. Ordering Information The Reliable Supervised Closed Butterfly valves and associated Specify the following when ordering: equipment shall periodically be given a thorough inspection and test. NFPA 25, "Inspection,Testing and Maintenance of Water Model BFG-300 Butterfly Valve Based Fire Protection Systems," provides minimum maintenance Supervision requirements. • Valve Supervised Open(yellow indicator) • Valve Supervised Closed(white indicator) Guarantee Valve Size • 2-1/2"(65mm) For Reliable Automatic Sprinkler Co., Inc.guarantee,terms, and • 3" (76mm) conditions,visit www.reliablesprinkler.com. • 4" (100mm) • 6" (150mm) • 8" (203mm) Reliable Supervised Butterfly Valve Wiring Diagram-Valve in Supervised Position Figure 1 Supervised Normally Open Valve Supervised Normally Closed Valve FIRE ALARM CONTROL PANEL FINE ALARM CONTROL PANEL SUPERVISORY CIRCUIT SUPERVISORY CIRCUIT SI:TWO LEADS PER TERMINAL SiRED O RED S1 RED 0 0 YELLOW-I END YELLOW---- I OR NEXXTLIN DEVICE �/ U vELLOW OR NEND ER EXTLvIE DEVICE RESISTOR WHITE- WHITE WHITE WHITE O GREEN O GREEN ACTUATOR CASE GROUND ACTUATOR CASE GROUM S2;ONE LEAD PER TERMINAL ORANGE VOLTAGE (�� ORANGE VOLTAGE SZ O 0 BLUE SOURCE S2 ^//O SUE SOURCE BLACK NOTIFICATION DEVICE I BLACK NOTIFICATION DEVICE (LOAD) I LOAD) Notes: Rated: 5A-1/6HP-125/250VAC 0.5A- 125VDC 0.25A-250DC www.reliablesprinkler.com