Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications (11)
^/e-w ` 2a - 00410 RECEIVE® Name:Woodcraft 1202,c� r e TRANE Prepared For Oa SW 1 Unit lag:W4C-1 Quantity 1 Trane Precedent Heat Pump Packaged Rooftop MN 0 2023 CITY OF TIGARDK Unit Overvie M I 1 M! !fir I I I ry I i1AI 000' r i l !0I 11 1 Application Unit Size Supply Fan External Dimensions(in.) Operating Weight EER IEERJSEER Elevation. External Airflow Static Height Width Length Minimum Maximum DX cooling 5 Ton Pressure 12.30 14.30 0.00 ft 1800 cfm 0.750 n 3.41 ft 4.44 ft 7.39 ft 682.0 lb 1071.0 lb Unit Features Fresh Air Selection 3 hn,D bulb 0-100%w/baro rel p E. t Voltage/phaselhertz 208-230/60/3 MCA 63.00A rr\r MOP 70.00 A O MCA(230 w/Elec Heat)68.00 A \ * MOP(230 w/Elec Heat) 70.00 A Entering Dry Bulb 80.00 F Capacity Entering Wet Bulb 67.00 F Gross Total 60.23 MBh Ambient Temp 95.00 F Gross Sensible 45.89 MBh Leaving Coil Dry Bulb 56.09 F Net Total 58.46 MBh Leaving Coil Wet Bulb 56.00 F Net Sensible 44.12 MBh Leaving Unit Dry Bulb 57.84 F Fan Motor Heat 0.69 MBh Leaving Unit Wet Bulb 56.64 F Refrig Charge-circuit 1 11.5 Pb Heatin• Section : ...,,. .; Heat Pump Mode Secondary Heat Output Heating Capacity 57.30 MBh Heat Type Electric Output Heating Capacity with Fan 57.98 MBh Heating Stages 2 Heating Delta T 29.47 F Heating Capacity 12 kW@240,460,600 derate to unit Heating EAT 70.00 F voltage Heating Ambient Temp 47.00 F Electric Heat Output 40.98 MBh Heating Ambient WB 42.60 F Electric Heat Air Temp Rise 20.97 F Heating Ambient Relative 7000 Humidit y -11111 Indoor Fan Data Outdoor Fan Data Type FC Centrifugal Type Propeller Drive Type Direct Fan Quantity 1 Evap Fan FLA 7.60 A Drive Type Direct Indoor Fan Performance Outdoor Fan Performance Airflow 1800 cfm Condenser Fan FLA 1.50 A Design ESP 0.750 in H2O Component SP 0.100 in H2O Total SP 0.860 in H2O Supply Motor Horsepower 1.000 hp Indoor Motor Operating Power 0.67 bhp Indoor RPM 1059 rpm Accessories Power 4.13 kW Roof curb'.yes Circuit 1 RLA 17.50 A Circuit 2 RLA 0.00 A 2023/0610616:23 1 Page 1 of 13 �/��/�° Job Name:Woodcraft 0 If/y/�i Prepared For. Unit Tag:W4C-1 Quantity:1 Acoustics Sound Path 63 Hz 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz 6 :11 Ducted Discharge 81 dB 84 dB 72 dB 69 dB 66 dB 63 dB 63 dB 56 dB Ducted Inlet 76 dB 73 dB 63 dB 59 dB 58 dB 54 dB 52 dB 45 dB Outdoor Noise 90 dB 90 dB 85 dB 85 dB 83 dB 79 dB 74 dB 68 dB 2023/06/06 16 2 3:11 Page 2 of 13 TRAIN. Job Name:Woodcraft - /fflrY�iPrepared For. Unit Tag:For Quantity:1 ELECTRICAL/GENERAL DATA GENERAL R)(exa) WITH HEATER Model: WSC060H Oversized Motor Heeler kW Rating: 9.0/12.0 Unit Operating Voltage 187-256 MCA N/A Stage: 2 Unit Primary Voltage: 208 MIS: N/A MCA: 6304180 Unit Secondary Veleta: 230 MCB. NIA MFS 70.0/70.0 Unit Hertz'. MCB 70.0A00 Unit Phase: 3 SEER 12 3/14 3 Standard Motor Field Installed Oversized Motor Oversized Motor Field metaled Oversized Motor Minimum Circuit Ampatty 31.0 MCA WA MCA N/A MCA- WA Maximum Fuse Size: 450 MFS: N/A MFS: N/A MFS'. N/A Maximum(1ACR)Cirult Breaker. 45.0 MCB: N/A MCB: N/A MCB: N/A INDOOR MOTOR Standard Motor Outsbed Motor Field Installed Oversized Motor Number: 1 Number. N/A Number: N/A Horsepower: 1.0 Horsepower N/A Horsepower: N/A Motor Speed(RPM): — Motor Speed(RPM): WA Motor Speed(RPM)'. N/A Phase: 3 Phase: N/A Phase N/A Full Load Amps: 7.6 Full Load Amps: WA Full Load Amps: N/A Locked Rotor Amps: - Locked RotorAmps: N/A Locked Rotor Amps.: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number I Number 1 Horsepower 4.7 Horsepower 040 Phase: 3 : Motor Speed(RPM): 1100 Rated Lead Amps: 17.5 Phase: 3 Locked Rotor Amps: - Full Toed Amps: 1.5 Locked Rotor Amps: 56 POWER EXHAUST ACCESSORY (37) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type R410 Phase: N/A Type: Throwaway Horsepower. N/A Furnished: Factory Charge Yes 11.516 Motor Speed(RPM): N/A Number 4 co Cicuil PI NIA Full Load Amps: N/A Recommended 16"x25"x7 Locked Rotor Am ps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sting a tor installations in the United States only. 2.Refrigerant charge is an epproxinete value.Fore more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5_Value does not include Power Exhaust Accessory 6.EER s ruled at AHRI conditions and in arsomance with DOE test procedures. 7-Installation oohs power exhaust kit wit effect unit level MCA and could effect MOP sizing having a direct impact on existing hold wiring and unit prulacbon devices.The change in MCA/MOP is the sore responsbilay of the field installing party Irene will not issue new nameplates as a result of this awes exhaust accessory installation.FLA of the power exhaust kit option must be added to the MCA of the unit for building supply conductor sizing determination • 2023/06/06 16:23:11 ` J MUNE' Job Name:Woodcraft Prepared For. Unit Tag:Quantity:1 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 lb MOTORIZED OUTSIDE AIR DAMPER 0 O MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF � �\\ OVERSIZED MOTOR ® / / � BELT DRIVE MOTOR lN).. 047 OVERSIPOWER ZED ® �� � AUST 3001b ® `�.�j_ THROUGHT THE BASE ELECTRICAL(FIOPS) �!%// UNIT MOUNTED CIRCUIT BREAKER(FOPS) UNIT MOUNTED DISCONNECT(FlOPS) J POWERED CONVENIENCE OUTLET(FIOPS) 0 O HINGED DOORS(FIOPS) HAIL GUARD PACKAGED HEAT PUMP SMOKE DETECTOR,SUPPLY/RETURN CORNER WEIGHT ROOF CURB 78.0 lb CORNER WEIGHTS CENTER OFGRAVITIY SHIPPING NET AO 22801b © 1140Ib (E)LENGHT (F)WIDTH 777.0 b 0 177.0Ib Q 183 0lb 38' 22 NOTE_ 1.CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY l 2 TO ESTIMATE SHPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3.BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT.TO OBTAIN TOTAL WEIGHT,ADD ACCESSORY NET WEIG HT TO BASIC UNIT WEIGHT. 4.WEIGHTS FOR OPTIONS NOT LISTED ARE>5 LBS. '''.".. ''''':04hp.''''- 1r ....,. . 'moo „,.„, 40,-.0,44, ..0 -,,,,,,,,,.,,,,,4, ; ...„,„ ...,..1z, Nil , h ,,,,, ---„,. -...„,,,, „, .,,, ...-4-,-- , t, , % < ,,,, L,.,„„\,..,,:7:- 9ah,,,lk ".,-ri___----;-_--i_-/,),J,,,,,,. i ra PACKAGED HEAT PUMP RIGGING AND CENTER OF GRAVITY 2023/06/06 16:23:11 Page 5 of 13 Job Name:Woodcraft 0 TRAWE' Prepared W4C-, Ouantity:1 CLEARANCE FROM TOP OF UNIT 72' CLEARANCE 38" CLEARANCE 48" Oillilt ta:Z \ [1111 •1 N--- r //� RETURN it \ �\ z�l DOWNFLOW CLEARANCE 38" HORIZONTAL CLEARANCE 18" CLEARANCE 38" PACKAGED HEAT PUMP CLEARANCE ROOF OPENING I I UNIT OUTLINE 46" 7 53 VC I 1i 1 LL--- 4s ------t - 88 5!8" PACKAGED HEAT PUMP DOWN FLOW TYPICAL ROOF OPENING 2023/06/061623:11 Page 6 of 13 TRAN i" Job Name:Woodcraft Prepared For: Unit W4C-1 Quantity:1 NOTES: RETURN OPENING 1.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION SUPPLY OPENING i 1 11/16- —18 7/16--4 8 5/8" r18 7/16"-- 11 11/16" 34 3/8" 34 3/8" 46 7/16" 2" 2 • 3 15116' ® 49 13/16"— 14' 14" .7-779 it L--------- 84 1/2" ,— L 50 7/16'� ROOF TOP CURB(BAYCURB043) ACCESSORY 2023/06/06 16:23:11 Page 7 of 13 S m a a AA � W ' iltiSY 2 / . 6. 2 A 0 0 W W --—* S N Q i , '( , 7 V * k LLv Oft I i°\/ ,a \ • 0., Y au-= 4- O h W 3 c oa N m ����/c Job Name:Woodcraft // ANE Prepared For Unit Tag:W4C-1 Quantity:i z pel: \v ' 0. f �i At 1114 \ ECONOMIZER Hoop 1.4:.:•••..;:.:: :.:::.:: .:..::.:,...: Hik. : 0M1H000 III 00 Ml= MIME 00 _____- 16314 - ACCESSORY-ECONOMIZER HOOD 2023/06/06 16:23:11 Page 10 of 13 • Job Name:4Q-1 Woodcraft MANE' Prepare°For: -rr`- QuaTag1 C7uanHty:1 • General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Case Unit casing shall be constructed of zinc coated, heavy gauge, and galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil-faced, fire-retardant permanent, odorless glass fiber material. All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8" high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2" MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Refrigerant Circuits Service pressure ports, and refrigerant line filter driers are factory-installed as standard. An area shall be provided for replacement suction line driers. Evaporator and Condenser Coils Internally finned, 5/16"copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 650 psig and pressure tested to 450 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning. A removable, reversible, double-sloped condensate drain pan with through the base condensate drain is standard. Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fan Standard efficiency 6 to 8.5 ton units come standard with belt drive motors with an adjustable idlerarm assembly for quick-adjustment to fan belts and motor sheaves. All high efficiency and 10 ton standard efficiency shall have variable speed direct drive motors. All motors shall be thermally protected. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). 2023/06/061623:11 Page 11 of 13 ° 0 0Job Name:Woodcraft�d�/�° Job Name W. ������rr������ Unit Tag:216-1 Quantity:1 Controls • Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized Microprocessor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Electric Heaters Electric heat modules shall be available for installation within basic unit. Electric heater elements shall be constructed of heavy-duty nickel chromium elements internally delta connected for 240 volt, wye connected for 480 and 600 volt. Staging shall be achieved through ReliaTel. Each heater package shall have automatically reset high limit control operating through heating element contactors. All heaters shall be individually fused from the factory, where required, and shall meet all NEC and CEC requirements when properly installed. Power assemblies shall provide single point connection. Electric heat modules shall be UL listed or CSA certified. Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. Accessory - Roof Curb The roof curb shall be designed to mate with the unit's downflow supply and return and provide support and a water tight installation when installed properly. The roof curb design shall allow field fabricated rectangular supply/return ductwork to be connected directly to the curb. Curb design shall comply with NRCA requirements. Curb shall be shipped knocked down for field assembly and shall include wood nailer strips. Sequence of Operation (if applied in a SINGLE-ZONE CONSTANT-VOLUME SYSTEM or a CHANGEOVER BYPASS SYSTEM) B. SINGLE-ZONE CONSTANT-VOLUME SYSTEM 1. OCCUPIED HEAT/COOL: The RTU shall operate the supply fan continuously and modulate (or cycle) compressors, modulate (or stage) heat, and/or enable airside economizing to maintain zone temperature at setpoint. The OA damper shall open to bring in the required amount of ventilation. 2. MORNING WARM-UP/PRE-COOL: The RTU shall operate the supply fan and modulate (or cycle) compressors or modulate (or stage) heat to raise/lower zone temperature to its occupied setpoint. The OA damper shall remain closed, unless economizing. D. CHANGEOVER BYPASS SYSTEM 2023/06/06 16.23:11 Page 12 413 • . aft MANE" Job Name:Woodcraft Pre ForW4' Unit Tag:pared C-1 Quentity;i 1. OCCUPIED HEAT/COOL: Each VAV terminal shall use pressure-independent control, with airflow measurement, to vary primary airflow to maintain zone temperature at its occupied setpoint. The RTU shall modulate the bypass damper to maintain duct static pressure at setpoint and modulate (or cycle) compressors, modulate (or stage) heat, and/or enable airside economizing based on current zone cooling/heating demands. The OA damper shall open to bring in the required amount of ventilation. 2. MORNING WARM-UP/PRE-COOL: Each VAV terminal unit shall vary primary airflow to raise/lower zone temperature to its occupied setpoint. The RTU shall modulate the bypass damper to maintain duct static pressure at setpoint and modulate (or cycle) compressors or modulate (or stage) heat based on current zone cooling/heating demands. The OA damper shall remain closed, unless economizing. 3. COOLING/HEATING CHANGEOVER LOGIC: The System Controller shall determine the overall system cooling/heating mode based on "voting" from each zone. When the majority of zones require cooling, the RTU shall operate in cooling mode and any zone that requires heating shall reduce primary airflow to minimum. When the majority of zones require heating, the RTU shall operate in heating mode and any zone that requires cooling shall reduce primary airflow to minimum. 2023/06/06 16:23'11 Page 13 of 13