Permit (19) CITY OF TIGARD MASTER PERMIT
II III
DEVELOPMENT Permit#: MST2023-00292
Date Issued: 07/06/2023
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 parcel: 1 S135CA05300
Jurisdiction: Tigard
Site address: 11107 SW VERDE TER
Subdivision: DAKOTA VILLAGE Lot: 7
Project: Campagna
Project Description: Rooftop solar PV system 6.4 kW
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $29,889.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Drains: 0 Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning; N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add?500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
•
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All N
Other: N Other Description: Roof top solar array 6.4 kW Ecompasing:
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
ALT SF VB R-3 0
Owner: Contractor:
CAMPAGNA,KIMBERLY&GREGORY GREEN RIDGE SOLAR Required Items and Reports(Conditions)
11107 SW VERDE TER 19450 SW MOHAVE CT
TIGARD,OR 97223 TUALATIN,OR 97062
PHONE: PHONE: 503-395-1943
FAX:
Total Fees: $356.69
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work
will be done in accordance with-.,approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more
,„
the 180 days. ATTENTI : Or gon law requires you to fallow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
::::::::
fhrnink AR m11noon V Main a rnnv of tha rnlac nr dirart nnactinnInillNCby Walln e;fri` Permittee Signature:
Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project.
Approved plans are required on the job site at the time of each inspection.
Building Permit Application
Residential FOR OFFICE USE ONLY
Dale/Bed �Z3'Oa
City of Tigard R (� { �+a a Y Permit[ o.:
3 g �/ G N . _ DanRe R2
• 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review ��t '�/e A�
' Phone: 503.718.2439 Fax: 503.598.1960 Date/By: CO V 1$i Other Permit:
TIGARD Inspection Line: 503.639.4175 JUN Date Ready/By: l FaSee Page 2 for
Internet: www.tigard-or.gov Notified/Method: 1 (> Supplemental Information
TYPE OF WORT' ,, REQUIRED DATA:I-AND 2-FAMILY DWELLING
❑New construction ❑Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
❑Addition/alteration/replacement ®Other:Solar Installation equipment,materials,labor,overhead,and the profit for the
CATEGORY OF CONSTRUCTION work indicated on this application.
® I-and 2-family dwelling ElCommercial/industrial
Valuation: $29,889
❑ Number of bedrooms:
Accessory building El
❑Master builder ❑Other: Number of bathrooms:
JOB SITE INFORMATION AND LOCATION Total number of floors:
Job site address:11 107 SW Verde Ter New dwelling area: square feet
City/State/ZIP:Tigard, OR 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name:Campagna Solar Project Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
REQUIRED DATA:COMMERCIAL-USE CHECKLIST
Subdivision: Lot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
DESCRIPTION OF WORK work indicated on this application.
Hookup and installation of 6.4 kW roof mounted solar system Valuation: $
Existing building area: square feet
New building area: square feet
® PROPERTY OWNER 0 TENANT Number of stories:
Name:Gregory& Kimberly Campagna Type of construction:
Address:11107 SW Verde Ter Occupancy groups:
City/State/ZIP:Tigard, OR 97223 Existing:
Phone:( )503-737-7132 Fax:( ) New:
® APPLICANT CONTACT PERSON BUILDING PERMIT FEES*
Business name:Green Ridge Solar (Please refer`o fee schedule)
Structural plan review fee(or deposit):
Contact name:Amanda Owen
Address:19450 SW Mohave Ct FLS plan review fee(if applicable):
Total fees due upon application:
City/State/ZIP:Tualatin, OR 97062
Amount received:
Phone:( 503)395-1943 Fax: :( )
E-mail:permitting@greenridgesolacwm PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES*
Commercial and residential prescriptive installation of
CONTRACTOR roof-top mounted PhotoVoltaic Solar Panel System.
Business name:Green Ridge Solar Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:19450 SW Mohave Ct Solar Installation Specialty Code checklist.
City/State/ZIP:Tualatin, OR 97062 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:( 503)395-1943 Fax:( )
State surcharge(12%of permit fee): $21.60
CCB lie.:210450 Total fee due upon application: $201.60
Authorized signature: -`� This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
*Fee methodology set by Tri-County Building Industry
Print name: Amanda Owen Date:6/22/2023 Service Board.
C\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I I/02/COM/WEB)
Building Permit Application Checklist
One- and Two-Family Dwelling FOR OFFICE ETSE ONLY
Received
- City of Tigard Permit No.:
Date/By:
11‘ 13125 SW Hall Blvd.,Tigard,OR 97223
Phone: 503.718.2439 Fax: 503.598.1960 Associated permits:
24-Hour Inspection Line: 503.639.4175 0 Electrical ❑ Plumbing ❑ Mechanical
TIGARD
Internet: www.tigard-or_gov ❑ other.
THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A
I Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ 0 0
2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. 0 ❑ ❑
3 Verification of approved plat/lot. 0 ❑ ❑
4 Fire district approval required. Name of district: . ❑ ❑ ❑
5 Septic system permit or authorization for remodel. Existing system capacity . ❑ ❑ ❑
6 Sewer permit. 0 0 ❑
7 Water district approval. ❑ ❑ ❑
8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ ❑
9 Erosion control ❑plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ ❑
basin protection,etc.
10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state 0 0 ❑
building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size
sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if
copyright violations exist.
11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if 0 ❑ 0
there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft. intervals);location of easements
and driveway; footprint of structure(including decks); location of wells/septic systems;utility locations;direction
indicator;lot area;building coverage area;percentage of coverage; impervious area;existing structures on site;and
surface drainage.
12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ El ❑
and location.
13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, 0 0 0
furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc.
14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑ ❑
floor,wall construction,roof construction. More than one cross section may be required to clearly portray
construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings
and foundation,stairs,fireplace construction,thermal insulation,etc.
15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ❑ ❑ ❑
Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope.
Full-size sheet addendum showing foundation elevations with cross references are acceptable.
16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ ❑ ❑
prescriptive path analysis provide specifications and calculations to engineering standards.
17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ 0 0
locations. Show attic ventilation.
18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ ❑
systems,see item 22,"Engineer's calculations."
19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ 0 0
over 10 feet long and/or any beam/joist carrying a non-uniform load.
20 Manufactured floor/roof truss design details. 0 ❑ 0
21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required 0 0 0
for four or more appliances.
22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ ❑
architect licensed in Ore:on and shall be shown to be applicable to the .ro-ect under review.
JURISDICTIONAL SPECIFICS
23 Three(3)site plans are required for item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". ❑ ❑ 0
24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ ❑ ❑
25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. 0 ❑ 0
26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 ❑ 0
27 "Drawn to scale"indicates standard architect or engineer scale. 0 0 0
28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard 0 0 0
Street Tree List,
29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑
and protection measures must be drawn to scale and must include the project arborist's signature of approval.
30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ 0
including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings
on a lot of record approved prior to September 9, 1995.
I:\Building\Pertnits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(I I/02/COM/WEB)
Electrical Permit Application RECEIVE I FOR OFFICE USE ONLY
City of Tigard
Received `/ Z��
n DateBy Permit#: J`��3—(�
• 13125 SW Hall Blvd.,Tigard,OR 97223 ,i�N 2 2, LUvt Plan Review
0 Phone: 503.718.2439 Fax: 503.5981960 DateBy: Related Permit it:
Inspection Line: 503.639.4175 ReadyDate/By.: kids: H See Page 2 for
TIGARD CITY OF TICI±'. Date/By.:> Internet: www.tigard-or.gov Notified/Method: Supplemental Information
TYPE OF WORK' n, PLAN REVIEW
❑ New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked):
0 Service or feeder 400 amps or more 0 Building over three stories.
El Demolition ®Other:
Solar Installation where the available fault current ❑Marinas and boatyards.
CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings.
® I-and 2-family dwelling ❑ Commercial/industrial ❑Accessory building less to ground,or exceeds 34.000 ❑Commercial-use agricultural
amps for all other installations, buildings.
❑ \lulu-family ❑ Master builder ❑ Other: 0 Fire pump. 0 Installation of 150 KVA or
JOB SITE INFORMATION AND LOCATION ❑Emergency system. larger separately derived
Job#: Job site address: El Addition of new motor load of system.
JO
11107 SW Verde Ter I00HP or more. ❑"A "E"."I-2","I-3",
City/State/ZIP:Tigard, OR 97223 0 Six or more residential units. occupancy.
g ❑Health-care facilities. ❑Recreational vehicle parks.
Suite/bldg./apt.#: Project name:Campagna Solar Project ❑Hazardous locations. 0 Supply voltage for more than
0 Service or feeder 600 amps or more. 600 volts nominal.
Cross street/directions to job site: ' ;" FEE SCHEDULE
�;x �,�
Description I DD. I Each I Total
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#: Ea.add'I 500 sq.ft.or portion 33.92 1
DESCRIPTION OF WORK Limited energy,residential
(with above sq.ft.) 75.00 2
Hookup and installation of 6.4 kW roof mounted solar system Limited energy,multi-family
residential(with above sq.ft.) 75.00 2
Renewable Energy [ See Page 2
® PROPERTY OWNER 0 TENANT Services or feeders installation,a eration,and/or relocation
Name:Gregory & Kimberly Campagna 200 amps or less 100.70 2
Address:1 1107 SW Verde Ter 20t amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard, OR 97223 601 amps to 1,000 amps 301.04 2
Phone: ( )503-737-7132 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email:gregory_campagna@hotmail.com relocation
Owner installation:This installation is being made on property that 1 own which is not 200 amps or less 59.36 I
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
® APPLICANT ® CONTACT PERSON Branch circuits-new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name:Green Ridge Solar above service or feeder fee, 742 2
each branch circuit
Contact name:Amanda Owen B.Fee for branch circuits without
serAddress:19450 SW Mohave Ct branchce fu fee,first
circuitit 56.18 2
City/State/ZIP:Tualatin, OR 97062 Each add'l branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:( 503)395-1943 Fax: :( ) Each manufactured or modular
dwelling,service and/or feeder 67.84 2
Email:permitting@greenridgesolar.com Reconnect only 67.84 2
CONTRACTOR Pump or irrigation circle 67.84 2
Business name:Green Ridge Solar Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy 0 See Page 2 2
Address:19450 SW Mohave Ct _panel,alteration,or extension.
City/State/ZIP:Tualatin' OR 97062 Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Phone:( 503)395-1943 Fax: ( ) Investigation(I hr min) 90.00/hr
Email:permitting@greenridgesolar.com Industrial plant(I hr min) 78.18/hr
Inspections for which no fee is ,
CCB Lic.:210450 Electrical Lic.:C1490 Suprv.Lic.:6478S
specifically listed('G hr min) 90.00 hr
ELECTRICAL PERMIT FEES
Suprv.Electrician signature,required:wOi.Sz ,:eld Subtotal:
Print name: Brian Butterfield Date:6/22/2023 0 Plan Review Required(25%ofpermit fee):
State surcharge(12%of permit fee):
Authorized signature: (Af-•--- TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
Print name: Amanda Owen Date:6/22/2023 days after it has been accepted as complete.
* Number of inspections allowed per permit.
I:\Building\Periniis\ELC_PermitApp_ELR_ERE.doc Rev 06/172015 440-4615T(I I/05/CIOM/WEB
Electrical Permit Application—City of Tigard
Page 2-Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
RESIDENTIAL WORK ONLY: FEE SCHEDULE
Ries
Fee for all residential systems combined: S75.00 Renewable
i Each T°ral
Qty.electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 1 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
❑ Garage Door Opener* >100 kva(fee in accordance
with OAR 918-309-0040) 552.26 2
r] Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System*
Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva-no additional charee 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr
charged at an hourly(I hr min)
Inspections for which no fee is 90.00/hr
specifically listed( hr min)
COMMERCIAL WORK ONLY: ELECTRICAL PERMIT FEES
Fee for each commercial system: $75.00 allowed
Subtotal rpernster on Page 1):
' Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
Li Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015
City of Tigard RE EIv c.
" Building Division
' in 13125 SW Hall Blvd,Tigard, OR 97223
Phone: 503.718.2439 Fax: 503.598.1960 LITY OF TiGF
T I GARD Inspection Line: 503.639.4175 6UILOING [7I1�Iti; 11�.
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 11107 SW Verde Ter
City: Tigard, OR Zip: 97223
Owner's Name: Gregory & Kimberly Campagna Date: 6/22/2023
Contractor's Name: Green Ridge Solar CCB #: 210450
Design Parameters of the Property/Structure
If"Yes", does not
Is the installation qualify for the
Flood Hazard Yes
Located in a flood ❑ prescriptive path, follow
Area plain/flood way? ® No OSSC or ORSC for
design requirements.
Is the wind exposure Yes If"Yes", qualifies for
Wind Exposure "C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ® Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
Yes the prescriptive path.
above
❑ No
1
I:/BuildingTorms/PhotoVoltoic-Checklist02-0I-I I,docx
Is the construction
material wood and does ® Yes
Type of If"Yes", qualifies for
the construction qualify
Construction ❑ No the prescriptive path.
as "conventional light
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ® Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
If"Yes", qualifies for
Nominal lumber. ® Yes the prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance Yes
If"Yes", qualifies for
with Section 305.4(3) of ❑ No the prescriptive path.
the 2010 Oregon Solar
Code?
❑ Metal.
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
® of composition
shingle.
is the roof mounted ® Yes
Connections of solar assembly If"Yes", qualifies for
the solar assembly connected to roof No
to the roof framing or blocking ❑ the prescriptive path.
directly?
2
I-•Building/Forms/Photo Voltaic-Checklist02-01-I I.docx
Is the gauge 26 or less? ❑ Yes If"Yes", qualifies for
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
❑ If"Yes", qualifies for
Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted If the spacing falls
solar systems Spacing of clamps? Minimum 24 inches within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. ''/2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members n No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof V Yes the prescriptive path.
surface. No
3
I:Bui(ding/Forms/PhotoVoltaic-Checklist02-01-I I.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer:SEG Solar
Model Number:
SEG-400-BMD-HV
Listing Agency:UL
•
T:Building,!Forms/PhotoVoltaic-Checklist02-0I-I I.docx