HomeMy WebLinkAboutSpecifications 202.3-oo06, 6,66 ac.„-L-i-c_i-tor RECEIVED OFF%CE COPY P POTTER MAY 1 5 2023 AFC-50 1 The Symbol of Protection CITY OF TIGARD Fire Alarm Control Panel BUILDING DIVISION • Features vthsma,a • 50 addresses available on this analog addressable system `� • • Additional system capacity achieved via multi-point SLC modules • 99 software zones >rtE • NFPA 72 Compliant Smoke Sensitivity Test Built-In • System Operates as Class A or Class B for SLC,P-Link and NACs AFc-50 • 5 Amp Power Supply,Expandable to 310 amps • 2 NACS,Regulated,Rated at 3 Amps each,expandable to 188 • 2 Input/Output(I/O)Circuits for system flexibility rated at 1 Amp each • Strobe Synchronization and System Wide Sync for Gentex®, AMSECO®,Cooper Wheelock®and System Sensor®strobes • Dedicated Alarm,Supervisory and Trouble Relays • 4,000 Event History Buffer • Optional two line DACT with UD-1000 that can report General,Zone or Point Information • Built in IP Communicator • Ethernet Port for Programming and Network Connectivity • E-Mail System Status,Reports and Event Information f NYC Fire Dept. • Product includes 5 year warranty. Certificate of Approval 00) • 6256 I LISTED 7165-0328:0509 S735 Description Technical Specifications The AFC-50 is an analog/addressable fire alarm system with a total system capacity of 50 addresses.Additional capacity on the system is achieved Dimensions 16"W x 17"H x 3 7/e"D using multi-point SLC modules.The control panel utilizes the exclusive 3.0 Amps @ 120 VAC 50/60 HZ Potter protocol that includes a complete line of sensors and modules. AC Mains 2.0 Amps @ 240 VAC 50/60 HZ Each SLC may be comprised of any combination of smoke sensor,heat detectors or modules and allows for a total of 50 ohms of impedance and Enclosure 16 gauge cold rolled steel with removable may use any wire compliant with the National Electrical Code(NEC). locked door with Lexan viewing window The AFC-50 has a 5 Amp power supply with two Notification Appliance Standby Current-I30 mA Circuits(NACs)and two Input/Output(UO)circuits.The NACs are rated at Alarm Current-200 mA 3 Amps each and the UOs are rated at 1 Amp each.Each output is regulated • 5 Amps power for NACs,I/O,and P-Link andpower limited.In addition,each output is uniquely • 3 Amps per NAC,regulated tp q y programmable and Battery • 1 Amp per I/O circuit,regulated may be configured for steady signal, strobe synchronization, constant • Battery Charger range 8-55 Ah power, door holder power, or releasing. The strobe synchronization • Battery Charger voltage 27.3 VDC includes Gentex,AMSECO, System Sensor and Cooper/Wheelock and • P-Link maximum current of 1 Amp with the exclusive Quadrasyne each output may have a unique brand and all strobes will flash together. Temperature and 32°to 120°(0°C to 49°C)with a maximum Humidity Range humidity of 93%non-condensing. The NACs may be expanded using the PSN-1000 series intelligent power supplies.Each PSN-1000 adds another 10 Amps of power,2 additional input circuits and the AFC-50 will support up to 31 power supplies.The system will synchronize the strobes system wide.In addition,the PSN- I000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all circuit connections. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830133-REV B • 01/18 PAGE 1 OF 4 P POTTER AFC-50 The Symbol of Protection Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 50 addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD100-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PAD100-PHD Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135°Fahrenheit heat detector. PAD100-HD Analog Fixed(135d-185dF)or Rate-of-Rise Heat Detector(software selectable) PADI00-DUCTR Addressable Duct Smoke Detector with Form C Relay.Addressable Duct Smoke Detector with Form C relay rated at l0a @ 250/120VAC or 8amps at 30VDC. PAD100-DUCT Addressable Duct Smoke Detector. PAD100-6B 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD100-4B 4"round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD100-IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC.Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call, • PAD 100-CD Addressable CO gas detector. PAD 100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. Modules Device Description PAD100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PAD100-PSSA Single Action Addressable Pull Station. PAD 100-PSDA Dual Action Addressable Pull Station. PADl00SIM Single Input Module is a standard contact module with an LED that mounts into a 4"square eleuhical box. PAD100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD100-TRTI Two Relay Two Input module provides two fonn C relays that are individually controlled by the control panel.Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC.Also provides two contact inputs. PAD100-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD 100-1M Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PAD100-RM Relay Module that provides one form C relay controlled by the control panel.Relay is rated for 2 amps at 30VDC or 0.5 amps at I25 VAC. PAD100-LED Module provides a single addressable LED that is controlled by the control panel. PAD100-SM Speaker Module provides switching for two audio channels. PAD100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD 100-DRTS DUCTR Remote Test Switch that mounts in a single gang box and optionally supervised.For use with the PAD 100-DUCTR only. PAD100-OROI One Relay One Input Module provides one form C relay and one input.The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.conf 8830133-REV B • 01/18 PAGE 2 OF 4 P POTTER AFC-50 e The Symbol of Protection Fire Alarm Control Panel Dimensions - 0 01 TOP • • DEPTH=3.75" • 0 L.__ DOOR= 16.07" BACKBOX=15.77" DEPTH=3.84" 0 1 r • • c • • 0 ( 0 0 ce x O m ' Q 4 m LEFT SIDE RIGHT SIDE BOTTOM ' DWG 05931 Ordering Information Model Description Stock No. AFC-50 Fire Alarm Control Panel 3992752 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.coni 8830133-REV B • 01/18 PAGE 4 OF 4 P POTTER RA-6075 ® The Symbol of Protection LCD ANNUNCIATOR INSTALLATION Address Settings - The RA-6075 address is set by dip switch Sl located on the back of the RA-6075.The address must be set in the range of 1 to 31 to be recognized by the control panel. Figure 3:RA-6075 Class A(back panel view) m 0 I — o 0 — a.en ,ii 0 91,1121 0 .11 .1 rot ,1`, 6 I f_ i!j _ / OII O/ Dip Switch Settings Refer to the table below for dip switch settings per Annunciator Address. Annunciator Dip Switch Settings Annunciator Dip Switch Settings Address SW-1 SW-2 SW-3 SW-4 SW-5 Address SW-1 SW-2 SW-3 SW-4 SW-5 1 On Off Off Off Off 17 On Off Off Off On 2 Off On Off Off Off 18 Off On Off Off On 3 On On Off Off Off 19 On On Off Off On 4 Off Off On Off Off 20 Off Off On Off On 5 On Off On Off Off 21 On Off On Off On 6 Off On On Off Off 22 Off On On Off On 7 On On On Off Off 23 On On On Off On 8 Off Off Off On Off 24 Off Off Off On On 9 On Off Off On Off 25 On Off Off On On 10 Off On Off On Off 26 Off On Off On On 11 On On Off On Off 27 On On Off On On 12 Off Off On On Off 28 Off Off On On On 13 On Off On On Off 29 On Off On On On 14 Off On On On Off 30 Off On On On On 15 On On On On Off 31 On On On On On 16 Off Off Off Off On PRINTED IN USA MFG.#5406077-REV 3-1 PAGE 2 OF 2 9/I1 GEH 12VDC or 24VDC Low Profile Evacuation Horn Model Number Part Number Nominal Voltage Reverberant dBA at In Anechoic Room 10ft.,per ANSWL 464 dBA at 10ft. . GEH12-R 904-1239-002 12VDC 62-82 100 GEH12-W 904-1241-002 12VDC 62-82 100 GEH24-R 904-1205-002 24VDC 62-82 100 _ GEH24-W 904-1207-002 • 24VDC 62-82 100 GES3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Strobe Model Number Part Number Nominal Voltage Candela (ANSWL 1971) GES3-12WR 904-1235-002 12 VDC 15, 30, 60, 75 GES3-12WW 904-1237-002 12 VDC 15, 30,60, 75 GES3-24WR 904-1321-002 24 VDC 15, 30, 60, 75, 110 GES3-24WW 904-1319-002 24 VDC 15, 30, 60, 75, 110 GEC3 12VDC or 24VDC Selectable Candela, Low Profile Evacuation Horn/Strobe Model Number Part Number Nominal Voltage Candela Reverberant dBA at In Anecholc Room (ANSWL 1971) 10ft.,per ANSWL 464 dBA at 10ft. GEC3-12WR 904-1231-002 12 VDC 15, 30, 60, 75 62-82 100 GEC3-12WW 904-1233-002 12 VDC 15, 30, 60, 75 62-82 100 GEC3-24WR 904-1317-002 24 VDC 15, 30, 60, 75, 110 62-82 100 GEC3-24WW 904-1315-002 24 VDC 15,30,60, 75, 110 62-82 100 GE3 Product Strobe Current Ratings mA 9 ( Model Designations: 12 VDC(8-17.5 Volts) 24 VDC (16-33 Volts) W =Wall mount Candela 12VDC UL Max' 24VDC UL Max' R = Red Faceplate W =White Faceplate - 15cd 106mA 92mA 30mA 42mA All units are available in plain (no lettering). 30cd 131mA 141 mA 35mA 58mA Plain units are non-returnable. 60cd 186mA 260mA 66mA 97mA 75cd 237mA 312mA 80mA 116mA ALERT bezel available for order 110cd 103mA 161mA AGENT bezel available for order GE3-12 Product Horn Current Ratings GE3-24 Product Horn Current Ratings Horn Decibel Lamas Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 12VDC Minimum SPL Minimum SPL Horn Mode at loft.,per allot,per Max.operating e! at 10ft.,per at 10ft.,per Regulated 24VDC ANSWL484 ANSWL484 Horn Mode Max.Opetatina e (HIGH) (LOW) High Setting(mA) AN(HIGH) ANSWL484 High Setting(mA) (HIGH) (LOW) Temp 3 2400Hz 76 dBA 69'dBA 29mA Temp 3 2400Hz 78 dBA 71*dBA 28mA Temp 3 Mechanical 75 d8A 68'dBA 26mA Temp 3 Mechanical 76 dBA 70'dBA 25mA Temp 3 Chime 62*dBA 60'dBA 13mA Temp 3 Chime 70'dBA 66'dBA 15mA Continuous 2400Hz 79 dBA 74*dBA 29mA Continuous 2400Hz 81 dBA 74'dBA 28mA Continuous Mechanical 78 dBA 72*dBA 26mA Continuous Mechanical 80 dBA 72*dBA 25mA Continuous Chime 63'dBA 61*dBA 13mA Continuous Chime 70'dBA 66*dBA 15mA Whoop 78 dBA 71*dBA 55mA Whoop 82 dBA 69*dBA 56mA NOTES: • Operating temperature:32°to 120°F(0°to 49°C). The GEC3 and GES3 Series is not listed for outdoor use. • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. 12VDC models are DC only. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products(see Technical Bulletin Number 014). • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). ' RMS current ratings are per ANSI/UL average RMS method. ANSI/UL max current rating is the maximum RMS current within the listed voltage range(16-33VDC for 24VDC units)(8-17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units)(8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings,see installation manual. Tone Switch Locations TONE SWITCH POSITION 3 4 5 'I Mechanical Temporal3 ON ON ON [_ • ■■Zj7 Mechanical-Continuous OFF ON ON N . 2400Hz-Temporal 3 ON OFF ON _ 2400Hz-Continuous OFF OFF ON c w • Chime-Temporal 3 ON ON OFF H - A ■\ Chime-Continuous OFF ON OFF Whoop ON OFF OFF u-i ■ 1= S+ CIF Whoop OFF OFF OFF S+ "ii NOTE: — s- Mi MO • Switch Positions'I and 2 In the OFF position to ® J H+ sit select isolated horn and strobe power inputs • Switch Position 6 ON =HIGH dBA H- OIF • Switch Position 6 OFF=LOW dBA eir Gentex Super-Slide® Gentex Checkmate® Instant Mounting Bracket • I Voltage Verification Allows the installer to pre-wire thk It is often necessary to confirm the • the system, test for system ��, , voltage drop along a line of devices.The supervision, remove the signal `_`; _ access holes are provided in the back of head until occupancy, switch - . ` the terminal block to allow the voltage to out Gentex signals without 11ll be measured directly without removing the changing mounting brackets I I 1 device.Typically this would be done at the and has locking edge connector (''1 I�` �� � A end of the line to confirm design criteria. for snap-in-place installation. t NI Most measurements will be taken using '0 the S+and S-locations although access is provided to other locations. NOTE:Care should be taken to not short the test probes. / Candela selection slider Y _„ -- .� � switch. Depress center �� y �'"' .„--- --�--fi„ li and slide switch to desire � ti �'�- y. k` brightness level. r� " 1 f. i "- 11tl, 4 IAi i 11'r`' I�1i t 1 I,I; , ' Break off pin and insert a '1 �I t �I I" � �_--- Il it into hole at the bottom of �. ��� ' , I �I I iso u4 the selector to lock ,I,S .� I �l „ ile I ils MODEL �� 1 11 candela setting. Signal 1 M Ea"" 11 i ' F lj i,: , must be removed from • t ( 1 1 /g111 sa I•. 1 ' ! ' - i it Ill 11 bracket and pin pushed L. + j - �' forward from backside out I _ ` of hole to change i " candela. `r►..«� IL_, -= To remove bezel, grip both sides of bezel • and pull in a downward and outward motion. a GEC3/GES3 12 & 24VDC SERIES Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control Signal Signal Panel Panel S+ S+ S- H+ H- S+ g+ S• H+ H• Supervised O S J L SupervO d Is 6 SG 0��-9 6 S B 0 Signal orcutt �' „I"' Signal Circuit � END OF 1111E REeaTOR END LIRE NE TOR O © 'MIA '_END OF NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET(551-0031) AND/OR AVSM CONTROL MODULE MANUAL(550-0284) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. • When synchronizing the GE3 12VDC Series,the Gentex AVSM control module or Gentex synchronization protocol MUST be used. Architect & Engineering Specifications The audible and/or visible signal shall be Gentex GEH,GES3, GEC3 Series or approved equal and shall be listed by Underwriters Laboratories, Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 12VDC or 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The strobe appliance shall have an operating current of 42mA or less at 24VDC for the 15Cd strobe circuit and 92mA or less at 12VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models or a voltage range of 8-17.5 volts for 12VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 28 pounds per carton Important Notice: 551-0050-06 GENTEX These materials have been prepared by Gentex Corporation("Genie()for informational purposes only.are necessarily summary,and are not purported to serve as legal advice and should not be used as such. Gentex makes no representations and warranties,express or implied,that these materials are complete and CORPORATIONaccurate,up-to-date,or in conrphance whir all relevant local,state and federal laws,regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding interpretation of laws,regulations and rules and the application of such laws,regulallons and rules to Fire Protection Products Group•www.gentex.com nartbttlerhacl posers.Each persona activates can dillerenity agentlhe oblganons thalexist under applicable laws,regulations or rules.Therefore,these materials should be used nnly br inbneedonel 10985 Chicago Drive •Zeeland, Michigan 49464 purposes rand shuttle nnlbn used as a substitute brseeking praeasional legs,advice.Gomez wgl not be 616.392.7195 • 1.800.436.8391 •616.392.4219 Fax resp°"e•'a for any action or lollira to act in reliance upon the Information contained in the material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. PAD1 00-PSSA/PSDA P POTTER Addressable Pull Station ® The Symbol of Protection Single/Dual Action Setting the Address The PAD100-PS Series uses one SLC address assigned to the device.The address is set using the DIP switch located on the back of the PAD100-PS device. Pull Station Front View Fig I � I / .6 0-- 11-.1411ftl , P= oiNi111 PY w`��� , pull PAD100-PSDA PADl00-PSSA Pull Station Back View and Wiring - Fig 2 O i'I•I'I'I•I•I• 0 as:, O o C I log ri, 1 / FACTORY WIRED CONTACTS FROM FACP OR PREVIOUS DEVICE TO NEXT DEVICE Ordering Information Model Description Stock No. PAD100-PSSA Addressable Pull Station,Single Action 3992721 PAD100-PSDA Addressable Pull Station,Dual Action 3992720 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com' 8830097-REV D • 12/18 PAGE 2 OF 2 P POTTER PAD1 00-PD The Symbol of Protection Photoelectric Smoke Sensor Air Velocity Ratings The PAD100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously.If the system already has 30 LEDs on,the PAD100-PD will operate even though the LED may not illuminate. Operation The PAD100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled.The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status.The polling LED can be turned off if desired for less conspicuous operation. The PAD100-PD with the PAD100-4DB or PAD100-6DB has a low profile of less than two(2)inches to blend into the surrounding environment.The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD100-PD and the compatible control panel work in tandem to keep the sensitivity consistent.As the sensor is installed over time,the sensor compensates for the dirt in the unit until it is out of range.At that time,the panel will indicate a dirty sensor.The sensor will then have to be cleaned or replaced. The PAD100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the,sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE:As required by NFPA,do not install the sensors until all construction is complete and the work area has been thoroughly cleaned.If the sensors have been installed in a construction environment,they should be cleaned or replaced before the system is placed into service. Spacing The PAD100-PD is UL listed with a recommended maximum spacing of 30 feet.Refer to NFPA 72 for specific information regarding detector spacing, placement and special applications. Compatible Bases All bases will mount on a single gang,double gang,octagon,4"square or mud ring electrical box. Device Description Stock No. PAD100-4DB 4"Standard Base 3992731 PAD100-6DB 6"Standard Base 3992732 PAD100-IB 6"base with an isolator module included. 3992730 PAD100-RB 6"base with one Form-C relay contact. 2A @ 30VDC,0.5A @ 125VAC 3992728 PAD100-SB 6"base with sounder module included. Sound pattern is provided from external source. 3992729 PAD100-SPKB 6"base with speaker included 3992762 Ordering Information Model Description Stock No. PAD100-PD Photoelectric Smoke Sensor 3992733 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830108-REV D • 12/18 PAGE 2 OF 2 Nomb._50 WORKS WITH MOST PANELS Each of those panels can be different— FIRE PACKAGE If the existing panel supports Contact whether they're XR,XT or Corn Series, ID,it's a candidate for upgrading with your customers have the same user code DMP offers the PowerComF,allowing DualCom and CellCom communicators. management capabilities.They can also you to add new communication add,edit and delete user codes any are no issues with lockout codes. time technologies to an existing fire panel.Included in the package are: Simply add the DualCom or CellCom unit they need to. to the existing installation and program AVAILABLE BURGLARY COMMUNICATION • One AT&T or Verizon DualcomNF in your own account number. • One 505-12 Power Supply The DualComWZ provides control of UPGRADING HONEYWELL VISTA PANELS basic panel security functions and video. As part of the package,the The Corn Series modules can be It adds the ability to remotely interact communicator has all the power it programmed to easily take over with Z-Wave devices,enabling a variety needs without drawing from the panel. Honeywell VISTA panels.The of home automation features including This alleviates the need to perform any communicator can connect to a VISTA control of lights,door locks,thermostats battery calculations for the existing Series ECP bus,which will allow you to and more. fire panel. program the Honeywell panel remotely FIRE COMMUNICATION MOBILE SYSTEM CONTROL using Compass. The CellComF-LTE-V provides cellular With any one of DMP's CellCom or UPGRADE DSC POWERSERIES PANELS fire communication and the DualComNF DualCom communicators,you can You'll be able to connect to the offers both network and cellular fire easily update your customers'older PowerSeries panel through the Com communication.Either one works on residential and commercial systems to Series communicators to remotely any fire control panel via Contact ID the latest cellular communication links. manage all user codes and easily check captures.Both meet NFPA 72 standard With cellular in place,users can remotely zone status from the Virtual Keypad app. for single communication technology. access their panels via the Virtual Keypad app.This makes it possible to USER CODE MANAGEMENT FIRE PANEL TAKEOVER use their mobile devices to control basic With Virtual Keypad,your customers can DualComNF provides two tip and ring to arm/disarm functions and receive alerts. eliminate time and money spent managing easily take over existing fire panels with The DualComWZ provides control of user codes—this is especially meaningful two phone lines. Z-Wave home automation devices. with multiple sites.At one time,they can send a user code to multiple panels. Virtual Keypad App Version Features Feature Arming Only Version full Version Add-On Services for Full Version Arm and Disarm • • Notifications(Alarms,Open/Close,Trouble) • • View History • • View Zone Status • Manage User Codes • Activity Reports • Configure Real-Time Notifications • SMS or Email • Geofencing • Video Doorbell _. • SecureCom NVR SecureCom Video • Video Integration • • Central Station Video Verification • COM SERIES FOUR ZONES FIELD PANEL UPDATES TWO OUTPUTS Each Corn Series model provides four The Model 401 USB Flash Module Use outputs to connect to an arming zones for connection to burglary allows you to conveniently field update zone of an existing panel for control of control panel outputs.Zone 4 is firmware for the communicators that that panel via the app. intended for connection to the control would otherwise require the use of panel bell output. a computer and a Model 399 EASY UPGRADE FOR DIALER-ONLY PANELS Programming Harness. Older dial-up panels have new life with ENABLE VIDEO ON THE APP the addition of network or cellular With the Corn Series communicators, MODULE PROGRAMMING communication.Earn customer loyalty you can add up to six video cameras. Programming over network or cell by extending the life of their existing Via the Virtual Keypad app,users can via Dealer AdminT"or Remote Link.'" panels and add modern panel features remotely view their premises to cancel includes zone information and at the same time. or verify an alarm or simply check in on monitoring center communications. I children or senior adults.Users can also MULTIPLE CONNECTION OPTIONS ADD VIRTUAL KEYPAD APP capture still or video images. Enable the Virtual Keypad app on your Corn Series communicators can be customers'existing panels for a minimal FULLY SUPERVISED COMMUNICATION attached to the existing panel in a additional cost.Brand DMP's Virtual The Corn Series allows alarm messages variety of ways.It can capture Contact Keypad app with your organization's to be communicated to an SCS-1R ID messages from the dialer or connect logo and contact information to provide or SCS-VR Receiver over network or the four input zones from outputs on a daily reminder of your services. " Verizon or AT&T LTE networks.Sending the panel.Or it can sense the output alarm communication for burglary and of the bell of an existing alarm and fire control panels over network or the communicate the appropriate message LTE network provides higher speeds. to the monitoring center. Corn Series Features Model Carrier Hardwire Wi-Fi LTE Z-Wave Housing Honeywell DSC (ID 2TIp 4Zones 2 Outputs Power Network Color VISTA PowerSeries Capture &Ring Supply DualComNF-LV Verizon • • Red • • • • • • DualComNF-LA AT&T • • Red • • • • • • DualComW-LV Verizon • • White • • • • • DualComW-LA AT&T • • White • • • . • DualComWZ-LV Verizon • • • White • . • • • DualComWZ-LA AT&T • • • White • • • • • DualComN-LV Verizon • • White • • • • • DualComN-LA AT&T • • White • • • • • CeilCom-LTE-V Verizon •• White • • . • ▪ CellComF-LTE-V Verizon • Red • • • • • PowerComF-V Verizon • • Red • • • • • ▪ PowerComF-A AT&T • • Red • • . • • r, COM SERIES REFERENCE SHEET • Ordering Information DualComN-LV Universal Alarm Communicator with Accessories DualComNF-LV Universal Fire Alarm Communicator Hardwired Network Primary and LTE 381-2 18"Coax Extension with Hardwired Network Primary Backup(Verizon) 381-12 1'Coax Extension and LTE Backup(Vernon) DualComN-IA Universal Alarm Communicator with 381-25 25'Coax Extension DualComNF-IA Universal Fire Alarm Communicator Hardwired Network Primary and LTE 383 Cellular Antenna LTE/CDMA/HSPA+ with Hardwired Network Primary Backup(AT&T) 386 Wall Mount Antenna Bracket and LTE Backup(AT&T) (ell(om-LTE-V Universal Alarm Communicator 387-2 2 dB Attack Enclosure Antenna DualComW-LV Universal Alarm Communicator (Verizon) 387-4 4'SMA to N Extension Cable with Wi-Fi Primary and LTE Backup CellComF-LTE-V Universal Fire Alarm Communicator 387-8 8'SMA to N Extension Cable (Verizon) (Verizon) 387-25 SMA TO N CABLE,25FT,LMR195 DualComW-LA Universal Alarm Communicator with PowerComF-V Universal Fire Alarm Communicator 387-50 SMA TO N CABLE,50FT,LMR195 Wi-Fi Primary and LTE Backup(AT&T) (Verizon) 388-1 3 dB Fiberglass Antenna w/bracket DualComWZ-LV Universal Alarm Communicator PowerComF-A Universal Fire Alarm Communicator 388-2 2 dB Attack Enclosure Antenna with Wi-Fi Network Primary and LTE (AT&T) 388-3 3 dB MEG Antenna Backup with Z-Wave(Vernon) 685-R Surface Mount Conduit Backbox DualComWZ-LA Universal Alarm Communicator (Red) with Wi-Fi Network Primary and LTE 685-W Surface Mount Conduit Backbox Backup with Z-Wave(AT&T) (White) DualCom-HSG-W/10 Replacement Housing Specifications DuaKom Series CelKomF-LTE-V Dimensions 5.5"W.3.75"H.1"D Primary Power Nominal 12 VDC or 24 VDC ANSI/UL 864 Fire Protective Signaling Systems Open-Collector Outputs 2 Current Draw at 12 VDC (CID Capture) Zones 4 Standby 64mA Cellular Color Alarm 109 mA FCC Part 15:XMR201707BG96 Red DualComNF,CellComF-LTE-V Current Draw at 24 VDC XMR201909BG95M3 White DualComW,DualComWZ,DualComN, Standby 30 mA DualCom Series CellCom-LTE-V Alarm 82 mA FCC Part 15:XMR2017076G96 CefCom-LTE-V Power(om Series or FCC ID:XMR2019106G95M3 Primary Power 12 VDC Primary Power Nominal 12 VDC IC:10224A-2017098696 Current Draw Current Draw at 12 VDC or 10224A-2019BG95M3 Alarm 102 mA Standby 64 mA Underwriters Laboratories(UL)Listed Standby 55 mA Alarm 109 mA Peak Cellular DualComNF cellfomFlTE-V . Communication ANSVUL 864 Fire Protective Signaling Systems Primary Power 12-24 VDC Certifications (CID Capture) Current Draw at 12VDC CellCom Series DualComN Alarm 102 mA California State Fire Marshal(CSFM) ANSI/UL 1610 Commercial Burglary Standby 56 mA New York(FDNY)COA Current Draw at 24VD( For additional information, Underwriters Laboratory(UL)Listed Alarm 82 mA ANSI/UL 1610 Central Station Burglar(Cellular) go to DMP.com/Compl once Standby 30 mA ANSI/UL 1023 Household Burglar • ANSI/UL985 Household Fire Warning(CID Capture) 800-641-4282 I DMPcom 12500 N.Partnership mvd,Springfield,MO 65803 I Designed,engineered&manufactured in Springfield,MO using U.S.&global components. LIMITED WARRANTY:DMP warrants that the products manufactured by DMP shall be free from defects of manufacture,labeling,and packaging for a period of three(3)years from the invoice date to the original Buyer, • provided that representative samples of the defective products are returned to DMP for Inspection.To read the full DMP Limited Warranty,go to DMP.com7Warranty or check the DMP Price List or Catalog. Any third-party trademarks referenced herein are the property of their respective owners and do not indicate or imply any affiliation,sponsorship or endorsement of DMP or Its products. ©2021 Digital Monitoring Products,Inc.I LT-2428 121424