Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
Aim PHOTOVOLTAIC ROOF MOUNT SYSTEM 0 23 MODULES-ROOF MOUNTED - 8.395 kW DC, 8.235 kW AC, 10030 SW TIGARD ST, TIGARD, OR 97223 infinity solar INFINITY HOME SOLUTIONS PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SITE DETAIL: SHEET INDEX: RECEIVED6405 E MILL PLAIN NCOUVER WA 98661 SYSTEM SIZE: 8.395 kW DC UTILITY: PORTLAND GENERAL ELECTRIC PV 0.0: GENERAL NOTES AND PROJECT DATA DS 09: MOUNTING-DATA SHEET PHVAONE:1-800-818-0596 8.235 kW AC MSP: NEW 200A WITH 200A MAIN BREAKER PV 1.0: PLOT PLAN DS 10: RACKING-DATA SHEET wFwiTvsoLAR.coM MODULE TYPE&AMOUNT: (23)SUNTECH STP365S-B60/1AINHB ROOF MATERIAL: COMPOSITE SHINGLE PV 1.1: SITE PLAN DS 11: RACKING-GROUNDING J1.11_ 0 1 au MODULE DIMENSIONS: (LNV/H)69.1"/40.9"/1.4" ASCE 7-10 WINDSPEEDS: (3 SEC GUST IN MPH) PV 1.2: ROOF SECTION DS 12: RACKING-CERTIFICATION REVISIONS CITY OF TIGARD Descnvtion Dale Rev 1.1: MOUNT DETAILS INVERTER: (05)HOYMILES HM-1500N MICROINVERTERS RISK CATERGORY I: 100 _ (01)HOYMILES HM-700N MICROINVERTER RISK CATEGORY II: 110 E 1.1: 3-LINE DIAGRAM ?UILDING DIVISION (01)HOYMILES HM-350N MICROINVERTER RISK CATEGORY III-IV: 115 E 1.2: NOTES INTERCONNECTION METHOD: LINE SIDE TAP RACKING: GRASOL RACKING SYSTEM FOR COMP ROOF E 1.3: WARNING LABELS AHJ: CITY OF TIGARD ARRAY AREA: 19.66 SQFT x 23=452.2 SQFT DS 01: PV MODULE SPECIFICATION SHEET • GOVERNING CODES: DS 02: MICROINVERTER SPECIFICATION SHEET ` Signature with Seal LIABILITY DS 03: MICROINVERTER SPECIFICATION SHEET 2010 OREGON SOLAR INSTALLATION SPECIALTY CODE . 4 .... The City of Tigard and Its Approved plans DS 04: COMBINER PANEL CERTIFICATION 1% 2019 OREGON STRUCTURAL SPECIALTY CODE(OSSC) l�l� ' NEC) employees shall not be hall be on lob S°'_ :. DS 05: AC DISCONNECT UL CERTIFICATION ' ' 9a� : 2021 OREGON ELECTRICAL SPECIALTY CODE(2020 S, 3 DS 06: AC DISCONNECT UL CERTIFICATION ��- • }yC 2014 OREGON FIRE CODE(2012 IFC) responsible for discrepancies �? r e" S} which may appear herein. DS 07: JUNCTION BOX UL CERTIFICATION 1 PHOTOVOLTAIC NOTES: DS 08: WIRING SPECIFICATION T Project Name& 1.AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL WITH THE"SMACNA"-GUIDLINES FOR SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING °1, .7 Nit " '''' ' '''' 'OSWTigardSt, Address DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK SYSTEMS. UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL 22.ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING '" / ll i ard, 0 R 97223 'USA PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361) CONSIDERATION OF a^P AND r'P BE DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE s / " 2.ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT SPACING CAN BE CALCULATED.THE DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC THREAD-LESS COMPRESSION TYPE LATERAL FORCE DETERMINATION. Iv 3.MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED 23.A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB f - ✓ •, (W.) 4.NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER SITE PRIOR TO STARTING THE INSTALLING OF HANGERS AND/OR BRACES. ++ , "" z DISTRIBUTION SWITCH BOARDS,PANEL BOARDS,DISCONNECTING SWITCHES,TERMINAL CABINETS, 24.WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING ',. 1 W 1- in ETC. ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO NON-PRESTRESSED REINFORCED CONCRETE,USE CARE AND CAUTION TO AVOID CUTTING OR OFFICE COPY - ('1'+'.'" ' : • �' " WITHSTAND THE WEATHER. DAMAGING THE REINFORCED BARS.WHEN INSTALLING THEM INTO EXISTING PRE-STRESSED CONCRETE '• a W Cs1ti Q 5.JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE d' a rn cD sW Katheri e St c= 0 -z APPROPRIATE WATER RUN OFF. AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION.MAINTAIN A - 0 H 0 O 6.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. • - .1 J v Q BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. 25.THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW - . .. _..._- __.... M O < W W 7,SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. -- 8.WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD 26.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC 300.6 01,310.8 D) VALI DITY OF PERMIT '� 2\ SATELLITE VIEW APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. 27.GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE I Q o 0_ 9.JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE DC SIDE OF THE SYSTEM.(NEC 250.97) THE ISSUANCE OF A PERM IT \ pV o.o/ SCALE:NTS w • WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF 28.THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF BASED ON CONSTRUCTION \ MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WIRING SYSTEM.(NEC 690.34) SMALLER THAN#6 COPPER WIRE.(NEC 250.64 B) DOCUMENTS AND OTHE� 10.IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE 29.GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT aveaon (,� FOLLOWING WARNING AT EACH JUNCTION BOX,COMBINER BOX,DISCONNECT AND DEVICE WHERE THE BUSBARS WITHIN LISTED EQUIPMENT.(NEC 250.64 C) DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM Raleigh Hills UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE:'WARNING-ELECTRIC SHOCK HAZARD. 30.RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END.(CEC 250.64(E) 4\ THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT 31.WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, REQUIRING THE CORRECTION l)MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND(NECE 690.35(F)) A SIGN WILL BE PROVIDED WARNING OF THE HAZARD PER NEC 690.17.34.EACH UNGROUNDED OF ERRORS. ORSO4105,4 i • Sheet Name 11.ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED CONDUCTOR OF THE MULT-IWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER PHASE AND SYSTEM PER FROM ANY PHYSICAL DAMAGE. NEC210.5. - iit. 2t7 _ GENERAL NOTES 12.ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. 32.CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250.97&250.92(B)&LAMC 93.250.97. i AND PROJECT 13.OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. 33.DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ! DATA 14.ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31(E),LAMC 93.690.31(E) NI 't Metzger 15.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, 34.ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT, 10030 SW Tigard St, Sheet Size COMMISSIONING AND ACCEPTANCE WITH THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED JUNCTION&PULL BOXES,RACEWAY,ETC)SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURERS CITY OF TIiRD Tigard, OR 97223,USA ANSI B 16.DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BEAT THE OPTION OF THE INSTALLATION INSTRUCTIONS LAMC 93.690.110.3&93.110.3(B). CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 35.SCREWS,NUTS,BOLTS&WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE 11 I NT CAVED FO I27 CODE COMPLTA CE 11" X 17" 17.IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY STAINLESS STEEL LAMC 93.110.3(B). / Tigard ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS 36.NO PIPING,DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE Approved: f J L APPROPRIATE. 7 cf.-Ti) Sheet Number LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. ( 'I C: 18.WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT,ARISES ON THE DRAWINGS OR 37.ALL FIELD INSTALLED JUNCTION,PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS !! 1 PV 0.0 • SPECIFICATIONS,THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE(S)OR PANEL(S)SECURED BY Pc m t i t : TINE i t ZZ ®v S MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN REMOVABLE FASTENERS. Address: I ��KID Ste© THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM 38.REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE O b 36 REQUIRED BY THE ARCHITECTIENGINEER. BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SElite I$: , Durham 19.ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE HANDED SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. OVER TO THE OWNER'S REPRESENTATIVE AT THE COMPLETION OR WORK. 39.THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING By: PAT Date:20.ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING YfeilFaAin 21.THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE ROOF-COVERING MATERIAL.t1 " GENERAL NOTES AND PROJECT DATA 40.ALL ROOF MOUNTED CONDUIT WILL BE A MINIMUM 1/2'OFF THE ROOF SURFACE. 3 VICINITY MAP Pv o.o PV 0.0 SCALE:NTS , , PHOTOVOLTAIC ROOF MOUNT SYSTEM 0 infinity solar 23 MODULES-ROOF MOUNTED - 8.395 kW DC, 8.235 kW AC, 10030 SW TIGARD ST, TIGARD, OR 97223 INFINITY HOME SOLUTIONS PHOTOVOLTAIC SYSTEM SPECIFICATIONS: PROOF ACCESS POINT 640 PLA96661 IN ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS VANCOUVER WA-0598 PHONE: - 0598 SYSTEM SIZE: 8.395 kW DC THAT REQUIRE THE PLACEMENT OF GROUND LADDERS INFINmFY SOLAR.COM 8.235 kW AC OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND MODULE TYPE&AMOUNT: (23)SUNTECH STP365S-B60/WNHB LOCATED AT STRONG POINTS OF BUILDING REVISIONS CONSTRUCTION IN LOCATIONS WHERE THE ACCESS MODULE DIMENSIONS: (L!W/H)69.1"/40.9"11.4" POINT DOES NOT CONFLICT WITH OVERHEAD Desc"ptbn Date Rev INVERTER: (05)HOYMILES HM-1500N MICROINVERTER OBSTRUCTIONS SUCH AS TREE LIMBS,WIRES OR SIGNS. (01)HOYMILES HM-700N MICROINVERTER (01)HOYMILES HM-350N MICROINVERTER AHJ: CITY OF TIGARD Q y 70O3 g / N.\ O�"4 Signature with Seal NEW PV AC DISCONNECT VISIBLE, ® / c ,. LOCKABLE, LABELED DISCONNECT / / \\ RONToc �G WITHIN 10'OF UTILITY METER ROOF ACCESS POINT .� //� / \\ /,/Don 'QQ s -. l[1�' �r - _) / Ri�F / \ ST Project Name& it ) h �4). / �,-� Address 1 1� y03 Cs gj< \-`J / / /b l , \ T „er0 t� /_ �� ��(�� �� >Cri'�1� �v�� U i v / ( �� ( -, J v ' W I - � �° �' �y �l yJ J v onN.��" p 0) eel' (( ( --) PROPERTY LINE 40-6" �%� �q/� �l� �� J��vv c2, C.i_7 Z L (c �� � lilt 1 �li � ( J� ) sir � ' J ' vv ' c < ) ��` 1 Spy rrfl �1 �c�^� SHED : ._i . _ .. -),e,, - ( ( eii.II ,,•l - C 1 h, -� > j Sheet Name 2 ) j, �s�° �� �y�J� (� J opFR1)- PLOT PLAN PR PERTYLINE / 315L3" Sheet Size TREE TYP. — FENCE ANSI B NEW EXTERIOR MAIN SERVICE PANEL TIED TO 11" X 17" EXTERIOR UTILITY METER#24 534 409 Sheet Number N PV 1 .0 ROOF#1 (23)SUNTECH STP365S-B60N4NHB SLOPE:23° AZIM.:214° -1 PLOT PLAN \ Pv to SCALE:3/64"=1'-0" PHOTOVOLTAIC SYSTEM SPECIFICATIONS: NOTE: BILL OF MATERIALS SYSTEM LEGEND VISIBLE, LOCKABLE, LABELED DISCONNECT � 05 HOYMILES HM-1500N SYSTEM SIZE: 8.395 kW DC WITHIN 10'OF UTILITY METER ATTIC RUN-YES NUMBER OF MODULES 23 SUNTECH STP365S-B60AWNHB NEW EXTERIOR MAIN SERVICE PANEL&POINT OF V 8.235 kW AC ATTIC FAN-NO IM I INTERCONNECTION.TIED TO EXTERIOR UTILITY MODULE TYPE&AMOUNT: (23)SUNTECH STP365S-B60NVNH6 SHUTDOWN-YES NUMBER OF INVERTER 01 HOYMILES HM-700N METER#24534409, infinity solar" MODULE DIMENSIONS: (LANlH)69.1"I40.9"l1.4" INVERTER: (05)HOYMILES HM-1500N MICROINVERTERS 01 HOYMILES HM-350N I NEW VISIBLE,LOCKABLE,LABELED DISCONNECT INFINITY HOME SOLUTIONS 6405 E MILL PLAIN (01)HOYMILES HM-700N MICROINVERTER EATON BR STYLE 1-INCH LOAD CENTER K LOCATED WITHIN 10'FROM THE UTILITY METER VANCIXNER WA 98661 01 HOYMILES HM-350N MICROINVERTER COMBINER PANEL 1 PHONE:1-800-818-0598 ( ) 816L125RP INFINITY SOLAR.COM AHJ: CITY OF TIGARD AC DISCONNECT 1 60A FUSIBLE AC DISCONNECT,240V C NEW DEDICATED PV SYSTEM COMBINER PANEL, 70 NUMBER OF ATTACHMENTS 51 GRASOL GS-10 RAIL ATTACHMENTS REVISIONS Q RAILS 12 GRASOL RACKING SYSTEM 23 NEW SUNTECH STP365S-B60NJNHB MODULES s tlpt r Dale Rev 30 RAIL SPLICE 6 SPLICE KIT WITH NEW(05)HOYMILES HM-1500N,(01)HOYMILES S HM-700N&(01)HOYMILES HM-350N INVERTERS MID CLAMPS 38 MID CLAMPS/UFO Ro /1/7• Tic END CLAMPS 16 END CLAMPS!STOPPER SLEEVE .010Fy 49 GROUNDING LUG 4 GROUNDING LUG =FIRE PATHWAY °GS O Signature with Seal s)' CIRCUIT(S) ❑O =ROOFOBSTRUCTIONS //%/ CIRCUIT#1 - 12 MODULES WITH 03 MICROINVERTERS • =ATTACHMENT POINTS V///// CIRCUIT#2- 11 MODULES WITH 04 MICROINVERTERS =RAFTER Project Name& O -—- =RACKING SYSTEM Address —— =ATTIC RUN O =CONDUIT ATTIC RUN JUNCTION BOX w 7' 0 z O in p U) cmrn w oho III 0 p 0 ROOF SECTIONS z Id N ROOF#01 MODULE-23 o _. '' 11.. ��p SLOPE-23° J �Q ?�:� 1" L47,....10 AZIMUTH-214° o Q w w MATERIAL-COMPOSITE SHINGLE ct ch C7 z \ ti2/F� RAFTER SIZE&SPACING-2"X6'@ 16"O.C. ¢ o =O s -== '-sue �° \ TS > / ? jam r ? ��R lip �Ts w -/' /s �•?i� �1II Sheet Name °t� 0.-- MODULE,_ rAL ARRAY WEIGHT(LOAD SITE PLAN CALC'S) NEW EXTERIOR MAIN SERVICE PANEL& POINT OF INTERCONNECTION.TIED TO 'Poor � �. -� �','_� Number of Modules 23 Sheet Size 1 EXTERIOR UTILITY METER#24 534 409 ,ti . Module Weight 44.8 LBS , NEW PVAC DISCONNECT GROUPED = '( /'� 9+ Total Module(Array)Weight 1030.40 LBS ANSI B WITH SERVICE EQUIPMENT(VISIBLE, Number of Attachment point 51 11° X 17" LOCKABLE,LABELED) - -? •- Mounting System Weight / (Per Module) 1.5 LBS Sheet Number NEW AC COMBINER PANEL '' Mounting System Weight 76.50 LBS q Total System Weight PV . I a N (AtA,MWe9ht+MouaOi0 System WW1) 1106.90 LBS Weight at Each Attachment Point 20.20 LBS . (Array(Amy WeiylA1 Pomtlerof Aft achmentPab9 Module Area(69.1"x40.9") 19.63 SqFt Total Array Area 451.41 SqFt ‘ii II Distributed Load 2.36 Per SqFt -1 SITE PLAN (Totalotal aRotem o„Areaht/Total .."Are`) �„ Total Roof Area 2272 SqFt \ Pv 1.1 SCALE:1!8"=1'-0° Total Percentage or Roof Covered 19 87% Total Afray Ana/Total Roof kes 100 10 ROOF 1 infinitysolar INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE:1-800-818-0598 INFINITY SOLAR.COM REVISIONS Description Date Rev (N) PV MODULE 8'-9'� $�-9�1 z 2" X 6" RAFTER @ 16" O.C. Signature with Seal 6'-6" Project Name& m ---- Address 2'-11" 2'-11" 23.0° w1- 0 u, Nco 1110, , . . g QR < 6'-9" '14-5" _ '14-5" -6-9" 0 o 0 J Cn J u oa iw I_ 0 1= 0 w Sheet Name ROOF SECTION ROOF SECTION • EXTERIOR BEARING WALL EXTERIOR BEARING WALL ' Sheet Size ANSI B 11" X17" Sheet Number PV 1 .2 \1 ) ROOF SECTION RAL NOTES:GENERAL STRUCTU 0 S: 0 1. THE SOLAR PANELS ARE TO BE MOUNTED TO THE PV MODULE ROOF FRAMING USING THE GRASOL RACKING SEE(21S 1.1) FOR infinity solar SYSTEM WITH GRASOL GS-10 MOUNT ENLARGED VIEW INFINITY HOME SOLUTIONS ATTACHMENTS. THE MOUNTING FEET ARE TO BE \___ 6405 E MILL P AIN SPACED AS SHOWN IN THE DETAILS, AND MUST VANCOUVER WA 98661 BE STAGGERED TO ADJACENT FRAMING / PHONE 1-800-618-0598 MEMBERS TO SPREAD OUT THE ADDITIONAL INFINITY SOLAR.COM LOAD. 2. UNLESS NOTED OTHERWISE, MOUNTING i REVISIONS ANCHORS SHALL BE 1/4" LAG SCREWS WITH A / •"` TERS pc16"OC' Deserv1a" Date Rev MINIMUM OF 3" PENETRATION INTO ROOF \ "0 FRAMING. yyy� Z"X6��� 3. THE PROPOSED PV SYSTEM ADDS 2.5 PSF TO THE - 7 ROOF FRAMING SYSTEM. (E)COMPOSITE SHINGLE ROOF 4. ROOF LIVE LOAD=20 PSF TYPICAL,0 PSF UNDER N / Signature with Seal NEW PV SYSTEM. 5. GROUND SNOW LOAD=N/A PSF 6. WIND SPEED=110 MPH 7. EXPOSURE CATEGORY=C 8. RISK CATEGORY=II Project Name& Address / 1 \ ATTACHMENT DETAIL (SIDE VIEW) w st.t SCALE:NTS z co 0U5 0 N ~ cc � � �z SOLAR MODULE Jo 601 co CC .,. g D o < w w ct 0-aoz O = GRASOL GS 10 RAIL > ~ a w Sheet Name GS-FK-02 305MM ROOF FLASHING MOUNT DETAIL 7, Sheet Size BUILDING STRUCTURE ANSI B 11" X17" Sheet Number ROOF - S 1 .1 1/4"X 3"SS LAG SCREW 2.5' MIN. EMBEDMENT ( 2 ATTACHMENT DETAIL ENLARGED VIEW 51.1 SCALE:NTS SITE NOTES: GROUNDING NOTES: 1. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA 1. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND REGULATIONS. GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH infinity solar 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A USE. UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 2. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM INFINITY HOME SOLUTIONS 3. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, NEC TABLE 250.122. 6405E MILL PLAIN VANCOUVER WA 98651 OR BUILDING ROOF VENTS. 3. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES PHONE',1-800-818.0598 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). INFINITYSOLAR.COM ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 4. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 5. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN 690.45 AND MICROINVERTER MANUFACTURER'S INSTRUCTIONS. REVISIONS ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S 5. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN D r ter Dee Rev INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE BUILDING OR STRUCTURE. NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURER'S INSTALLATION EQUIPMENT LOCATIONS: REQUIREMENTS. 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT Signature with Seal 2. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED THE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES ANOTHER MODULE. 310.15(B)(2)(A)AND 310.15(B)(3)(C). 7. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED 3. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES GREEN OR MARKED GREEN IF#4 AWG OR LARGER[NEC 250.119] ACCORDING TO NEC 690.34. 8. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 Project Name& 4. ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED WHERE THE INVERTER IS NOT THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A Address WITHIN SIGHT OF THE AC SERVICING DISCONNECT.2.2.6 ALL EQUIPMENT SHALL BE GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC AND AHJ. APPLICABLE CODES. 9. GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR REDUCE FIRE HAZARDS USAGE WHEN APPROPRIATE. U DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: z co 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS p co ch rn STRUCTURAL NOTES: OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE <n o N o 1. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS). ix UJ Q rn o z CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED 2. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE 0 o O o SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH o"' BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAILS 3. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID J co cc M m o ¢ tuw MANUFACTURER'S INSTRUCTIONS. SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY ct o o z 2. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF RESPONDERS IN ACCORDANCE WITH 690.12(A)THROUGH(D). ¢ o ~ a ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL 4. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND t j REQUIREMENTS. 240. 3. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WI 5. MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. FUSES IN ACCORDANCE WITH NEC 110.3(B). 4. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE 6. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN ACCORDING TO NEC 690.11 AND UL16998. POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED Sheet Name AMONGST THE ROOF FRAMING MEMBERS. INTERCONNECTION NOTES: 1. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH[NEC 705.12(B)] NOTES WIRING&CONDUIT NOTES: 2. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT 1. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. EXCEED 120%OF BUSBAR RATING[NEC 705.12(D)(2)(3)]. Sheet Size CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE 3. THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT CIRCUIT CURRENT ANSI B REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL 2. CONDUCTORS SIZED ACCORDING TO NEC 690.8,NEC 690.7. NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR, PV DEDICATED 11" X 17" 3. VOLTAGE DROP LIMITED TO 1.5%. BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE Sheet Number 4. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING UTILITY SOURCE OCPD[NEC 705.12(B)(2)(3)1 SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE 4. AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL E 1 .2 WIRING CLIPS. RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF 5. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED PHASE B OR L2-RED,OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- ACCORDING TO NEC 705.12(B)(2)(3)(C). BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL-WHITE OR GREY 5. FEEDER TAP INTERCONECTION(LOADSIDE)ACCORDING TO NEC 705.12(B)(2)(1) IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO 6. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH BE MARKED ORANGE[NEC 110.15]. SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING[NEC 705.12(B)(5)]. / WARNING A 3 WARNING DUAL POWER SOURCE ELECTRICAL SHOCK HAZARD ElVf SECOND SOURCE IS PHOTOVOLTAIC SYSTEM Inifllty Solar TERMINALS ON BOTH LINE AND WARNING LABEL LOCATION:PRODUCTION/NET METER(BI-DIRECTIONAL) INFINITY 6405E MILL PLAIN LOAD SIDES MAY BE ENERGIZED POWER SOURCE OUTPUT 1., NEC:2020 VANCOUVER WA 98661 IN THE OPEN POSITION NEC 690.59,705.12(D)(3) PHONE 1-800-81B-059B CONNECTION.DO NOT RELOCATE INFINITY SOLAR.COM THIS OVERCURRENT DEVICE. LABEL LOCATION , i,A E,->:„--TION: i WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE LABEL LOCATION: REVISIONS ENERGIZED IN THE OPEN POSITION,A WARNING SIGN SHALL BE MAIN SERVICE DISCONNECT Desaplbn Date Rev MOUNTED ON OR ADJACENT TO THE DISCONNECTING MEANS. NEC:2020,705.12(B)(3)(2) PER CODE(S):NEC 2020:NEI PHOTOVOLTAIC SYSTEM AC DISCONNECT NEC 706.15(C)(4)and NEC 690.13(B) I I RATED AC OPERATING CURRENT 34.30 AMPS L MAIN PHOTOVOLTAIC AC NOMINAL OPERATING VOLTAGE 240 VOLTS Signature with Seal - M DIS • ,, . LABEL LOCATION: AC DISCONNECT,POINT OF INTERCONNECTION \WARNING r LABEL LOCATION: MAIN SERVICE DISCONNECT,NEC 2020,690.13(B) I NEC:2020 _IA (PER CODE:NEC 690.54) THIS EQUIPMENT FED BY MULTIPLE SOURCES, TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, - t C Project Name& s AMPACRY OF BUBBAR. Address LDABELTIONELOCATION:U A U T I O N PERMANENT WARNING LABELS SHALL BE APPLIED TO DISTRIBUTION EQUIPMENT,AC DISCONNECT • • NEC:2020 I PER CODE:705.12(B)(3)(3) I POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE u, FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS z co PHOTOVOLTAIC SHOWN. oCN DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES w ix N. Q J ct Q cD SOLAR PV SYSTEM o F o 2 a AC DISCONNECT EQUIPPED WITH RAPID LABEL LOCATION: SHUTDOWN 10030 SW TIGARD ST D o a LU LLLI AC DISCONNECT W i_ p H 0 (NEC:NEC 202013(B) Z X TURN RAPID a m 0 SHUTDOWN Ili 2 m SWITCH TO THE o "OFF POSITION TO SOLAR PHOTOVOLTAIC SYSTEM V SHUTDOWN PV ELECTRIC • SYSTEM AND PV PANELS EQUIPPED WITH - i REDUCE RAPID SHUTDOWN 1 I SHOCK HAZARD N THE ARRAY Sheet Name AT INVERTER[IFC 605.11.3.1(1)&690.56(C)] WARNING LABEL LOCATION: PER CODE:NEC 2020 UTILITY SERVICE ENTRANCE/METER,INVERTER/DC DISCONNECT LABELS IF REQUIRED BY LOCAL AHJ,OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. Sheet Size PER CODE(S):NEC 2020:ARTICLE 690,56(C) • PV ARRAY ANSI B -- -- - 11" X17" 0 vIACC t t - 23 PV MODULES — Sheet Number 4 JIB 4 E 1 .3 1 4 I L SOLAR PHOTOVOLTAIC MAIINSERVCETILITY TER — — ACDSCOM DISCONNECT SYSTEMS I I I (PER CODE:NEC 690) WARNING: PHOTOVOLTAIC _ _ _ _i _ J _ J POWER SOURCE L SOLAR PHOTOVOLTAIC LABEL LOCATION: EXPOSED RACEWAY,CABLE TRAYS,JUNCTION BOX SYSTEMS NEC:2020,PER CODE:NEC 690.31(D)(2) (PER CODE:NEC 690) 0 Technical Specifications Technical Specifications infinilysolar INFINITY HOME SOLUTIONS LAIN Model HM-300N HM-350N HM-400N Model HM-600N HM-700N HM-SOON 6405U R VANCOUVL ER WA 98661 PHONE 1-800-818-0598 Input Data(DC) Input Data(DC) INFINITY SOLAR.COM Commonly used module power(W) 240 to 405+ 28C+to 470+ 320 to 540* LsmrrzrI.'used mc.ile pOwwr.W1 242 to 405- 260 to 470- 32r ..`1L— REVISIONS Maximum input%soilage 1V) 5O Maxirr!:.lnt Inpur voltage(V11 Ir..1 Dexrplun pate Rev YP voltage range(V) 16-60 MPPT voltage range IV) 16-60 Stan-up voltage(V) 22 Start-up manage00 22 Maximum input cu rent ilk) 1` 11.5 121; Maximum input current(AI .:-:'t s 2x 11 1! 2x U.S Signature with Seal Output Data(AC) Output Data(AC) Beak.output power(VA) 300 350 .:Ir(c Peak outp.a power IVAI 600 Ica. Wu Maximum continuous output power(VA) 295 349 3 max im.Jmcontinuous output power(vA) S90 6.96 .nib Maximum continuous output c rrern Al 1.23 1,42 1.45 1.68 1-59 1.81 Maximum continuous a tp.ltcurrent(AY t 46 2.84 2 90 335 3.19 3 68 Project Name& I Slorninal 2401211-264 2081183-228 242011.264 2081183.225 2407211.264 208/183.228 Nominal artpur voltage/range(V) 240121I-264 2ow1e322R ._'<'1-2Aa TorvrtR3-22n 240r2I1.264 20en81-22P Address Nominal frequency/range(HZ)' 60/55-85 Pkaminal freq;ien yirange(HT) 60f5%s >1 99 defauN >o.9 y(*fails!Porer factor(adIuseable) co -7or(a rustablel0.81ead-xg .0.&lagging u.6leadlng_o8lag glno Total harmonic distortion -e 3% coral Fsarmcr..r dlgamon <39t LU U Maximum units per branch' 13 '- 11 9 1 r E Mtaxim.,m-oars per branch/ 6 _ S 4 S Z co 1.14 0 CO Cr) rn EffcIency Efficiency (I CI N ti CEC peak efficiency 96.7% LEC peak efficiency 96.71e ct Q rn co Z 0CECR.we C weighted efficiency 96.5% C !ghtec efficiency 9559t :i ~ CI- 2, --i Nominal MRPT efficiency 99.845 Nominal Mnkf-efficiency le a n O Q Eli w Jcrtttirre power consurnpnion(mW) <50 I- o O Nighttime power (WWI CSc o = a mechanical Data Mechanical Data w Armteent temperature range(°C) -40 lc:+55 Arno VT temperature I '.ge("C) -40 to-65 Dimensions(W•14.3 trim) 182• 164 a 29.5 Dimensrcrs69 e H e Dmm) 250•17(}a 28 Weight lkng) 1.93 Weigtttflss; 3 nclosur a rat inq t7utdour-NtMA 5(I'671 Endesure rating Outdoor-NEMtA a NMI; Sheet Name Cooling Nattier a:convection-Nu tans cooling Natural cortue_tlon-Nc fans MICROINVERTER R Features SPECIFICATION Features SHEET Communication 2_4G 4t mroptrietary•RF(Nordic) Camr^. r:I anon 2.Qti:,tic' ;apretaty RT fNordrvl Sheet Size Moretonr g 5-MI les Cloud' NMpntorin� 5-hSOes:Jcuer' ANSI B warranty Up to 25 pears Warranty 17p to 25 years 11" X 17° UL 1741,IEEE 1547,UL 1741 S 1240 Vac1,CA Rule 21 (240 Vac), Compliance lll 1741,1EEE 1547•(10 1741 SA(140 Vacl.LA Ride 21(14P Vac), Sheet Number C5.4 C22.2 Nu.107.1-16,FCC Part 1513.;CC Para 15C corn pia-re CSA C:242 Na.107.1-t 6.f rX Parr 156,PLC Part IX ?V Rapid Shutdown �'Rapid Shut6pwn Conforms enth NEC-2017 and NEC-202r Art IJe 690.12 conforms with NEL-2017 and NEC-2C20 Amide 690.12 DS 02 and CEC-2021 Sec 64-218 Rapid Sfrutdcnvr ul PJ Systems and CtC-20f-Sec 54-.18 aa_d 5hutdcwn of PV Systems *1 Iicrninaf Vl 1atge/trequency range can vary depending art total requirements. - -_ „oh aoar`requencp range can vary depending on local requirements. *2 Refer to local requirements for exact number of microinverters per ttran3i. . --- _.oral requirements forewatr number of mtirolnveners per branch. *3)foynnles Monitori!q System. • ,,;n4onrrcring System. Z 212.2`Ihrynt, = nmvori, b d 2S2' 1wni'e[.Power T,. '.�con s lru f r gls tr_e+vevJ. 18 Technical Specifications infinity solar --- - INFINITY HOME SOWTIONS Mode( HM 1200N HM-1500N 6405E MILL PLAIN VANCOLNER WA 98661 Input Data(DC) PHIINFFIINITY SOLAR COMNE: B Lomitnany used moalle power(wl 2.9t7 Eta REVISIONS Maximum Input voltage(v) 6:i DeuCr IEEn Dale Rev MPPT wattage range(91 16-60 stareaJp voltage(V) MaxImJm Input currant(Aj 4 K 11.5 4 a 11.5 Signature with Seal Output Data(AC) Peak Output power(Y'A1 1260 1200 1500 1350 MaxlmJni continuous otrtmt power p/A) 1200 1109 1436 1246 Maximum connnuous output current FA) 5 5:33 599 5.99 Project Name& Address Nominal 0.1ipur voltage/range( g 2401211-264 2013+ 83-228 240./211-26:4 208/1/33.2213 Nominal freanierscylrvnge(Hit 60155-65 defauh Power factor(achustablel U.S le�ingtiding._0.8 tagging w RarmontC dlstar ton s398co z Maximuim units per branch` 3 3 2 Wp cp on rn O N o Efficiency w < - co CEC.peak efficiency 96.79E 0 H 0 O LEL weighted efficiency 95.54E -. CO CC < w W Ct co Ur Nominal MPF'T efficiency 99-896 o F 0 Q 0440trirne power consumption(mw) <SO > a W Mechanical Data Aritreric temperature range('C) AGM*65 :Nmen5iOns(W a H.a 0 mm) 280 a 176 x 33 Weght(kg) 3.75 Sheet Nariw MICROINVERTER Enclosure rating Ourdeor-NEMA 6(1P67) SPECIFICATION Cooling Ong Natural convection-No fans SHEET Sheet Size FeatUreS corrnuneanon 2.4(pH?PropnetaryRI(Nortirl ANSI B 11" X 17" Monitoring s-Mdes Cloud Sheet Number Warranty Lip no 2 5 years corn pllar,^e LA.1141.IEEE 1547.UL 1 741 SA(240 VaQ.CA Rule 21(240 Va::, DS 03 ESA C222 NO. 107_ lb.FCC Parr 158,FCC Parr t5C F''V'f4aptj Shutdown Conforms with NEC-2017 and NEC-2021J Article 690.12 and CEC-2021 Sec 64-216 Papa Shutdown of W Systems •1 Norma tiashage^requercy range -an vary depending on local requirements. • Refer cc local requirements fo- ;-number of mtcfolnverters per branch. '3 H. afltles Mon-cm no`:y:err Int Asrigh8 rerwtred t✓ nity Et � NnfYHOMES SOLUTIONS INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 Powering Business Worldwide pe.eaton.com PHONE:1-80D-618-0596 INFINITY SOLAR.COM REVISIONS Description Dale Rev BR style 1-inch loadcenter Signature with Seal BR816L125RP UPC:786676001472 Dimensions: • Height: 13 IN PrgA & Add dressdress • Length: 3.56 IN • Width: 11 IN Warranties: • 10 year co Specifications: Lca I o w c, a, • Special Features: Current design o N o • Type: Main lug ct O z I • Amperage Rating: 125A ' 01 o JII • Box Size: 7r = • Bus Material: Aluminum wI o o 0 oz w • Cover: Cover included QI o • Enclosure: NEMA 3R Lu • Enclosure Material: Metallic • Interrupt Rating: 10 kAIC • Main Circuit Breaker: BR • Number Of Circuits: 16 Sheet Name • Number Of Spaces: 8 COMBINER PANEL • Number Of Wires: Three-wire • Phase: Single-phase CERTIFICATION • Voltage Rating: 120/240V Sheet Size • Wire Size: #14-1 AWG Cu/AI ANSI B Supporting documents: 11" X 17r • Eatons Volume 1-Residential and Light Sheet Number Commercial • Cutler-Hammer Type CH and BR Loadcenters - DS 04 Instructions • Type BR Arc Fault Circuit Breakers and Loadcenters • Eaton Specification Sheet- BR816L125RP 0 RSTC Enterprises, Inc. infinity solar 2214 Heimstead Road INFINITY HOME SOLUTIONS CllILADECK 640 PLAIN 406E MILL PLAIN VANCOUVER WA 98661 Eau Claire, WI 54703 PHONE:1-800-818-0698 INFINITY SOLAR.COM 715-830-9997 • FLASHED PV ROOF-MOUNT COMBINER/ENCLOSURES REVISIONS Descnplbn Bale Rev Outdoor Photovoltaic Enclosures 0799 Series CornpositioniCedar Roof System Signature with Seal ETL listed and labeled 0 0',,. Report#3171411PRT-002 Revised May, 2018 ' . • UL50 Type 3R, 11 Edition Electrical equipment enclosures Project Name& • CSA C22.2 No. 290 Nema Type 3R Address • Conforms to UL 1741 Standard ' ` 0799 Series Includes: in 0799-2 Wire size 2/0-14 z Oa 0799-5 Wire size 14-6 o u) co rn en 0N6 0799 D Wire size 14-8 cc CC as aCD z Models available in Grey,Block or Stainless Steel o J! to ,Y D o < w w Basic Specifications ; co lots > - a Material options: "' • Powder coated, 18 gauge galvanized 90 steel (1,100 hours salt spray) • Stainless steel Process- Seamless draw(stamped) Sheet Name Flashing - 15.25' x 17.25" Height 3" JUNCTION BOX UL Cavity-255 Cubic inches CERTIFICATION _ Sheet Size Base Platte: ' a. ANSI B • Fastened to base using toggle fastening system _ 11" X 17" a • 5 roof deck knockouts , • Knockout sizes: (3) .5% (1) .75'and (1) 1" meet Number • 8', 35mm slotted din rail DS 07 • Ground Block ,. Passthrough and combiner kits are available for either _:axa_, ,it AC or DC applications. Goss-Linked Polyethylene Insulated 2kV Rated PV 18-750 MCM•2000 Volts•-40°C to 90°C Wet and Dry infinity solar INFINITY HOME SOLUTIONS 6405 E MILL PLAIN Description VANCOUVER WA98661 PHONE:1-80D-818-0598 , ADC's Sofarlink brand Photovoltaic cabr'e has a chemically INFINITY SOLAR.COM 1 cross-linked polyethylene insulation. Bane Capper Applications REVISIONS ppDescription Dale Rev i Appropriate for use in solar power appaicatioins that require W2,000 volt rating. For use in grounded interconnection and I J ungrounded Photovoltaic power systems. Construction QCorte Stranded bare copper conductor per ASTM 5-3,B-8. Signature with Seal • it XLPE Insulation AN ailaole in 7 or 19 stranded versions as well as tinned copper. V♦ ♦ Insulation: Chemically Cross-linked polyethylene = Solar Colors: Black,Green,White,Red. Print on one side with a Q contrasting ink. An extruded stripe and other colors are ect avail- able upon request.. PmlAddresses Industry Listings & Standards �a UL Listed as Photovoltaic Cable per Standard Subject 4703 and 44 WI C: ,'''- identification -40°C/90°C Wet and Dry Rated •ADVANCED DIGnAL CABLE NC. )O(AWO(U14 Gasoline and Oil Resistant II w PV WIRE OR RHW-2^2000v OR USE-2 6 804C R Compliant ROHS z 00 ` WET OR DRY',-40C)SR GRIT DIRECT BURIAL Re‹, Sunlight Resistant a, w i 0 E321841' VW-1 Flame Rating Optional MO o o N co °' ct -cc rncoz CL Insulation Thick- Nominal O.D. . Approximate OJ � 0 o Pert Number AWG Strand nese (inch) Net weight - < (mile) lbel RC o Q ai w 3182NPV 18 7 76 .196 18 I- co O Ci 3162NPV 16 7 76 .208 ^^ < n- 3142NPV 14 7 76 .221 28 w 3122NPV 12 7 76 .242 38 3102NPV 10 7 76 .264 61 3082NPV 8 7 85 .314 78 3062NPV 6 7 86 .361 112 3042NPV 4 7 86 .390 166 Sheet Name 3032NP1/ 3 7 86 .427 203 WIRING 3022NPV 2 7 66 ASO 249 SPECIFICATION 3012NPV 1 19 105 .539 323 30102NPV 1,A 19 105 .672 390 Sheet Size 30202NPV 2A 19 105 .616 4.80 30302NPV 3.43 19 105 .667 603 ANSI B 30402NPV 4rV 19 105 .72 7.37 11" X 17" 3026021831/ 260IdC84 37 120 .798 878 Sheet Number k 303002N V 300 1 37 120 .845 1046 IY 3036CeNPV 350 Wv141 37 120 .901 1196 DS 08 t 304002NPV 400 I+JI1U 37 120 .9 6 1366 X 305002NPV 500 MOM 37 120 1.029 1673 0 c Z' 306002NPV 900 ti1C1,4 61 135 1.136 2011 307602NPV 750►tC144 61 135 1238 2618 -se nlvmffian cuite•:d is thb si xeralm E mended babe used at a guide I product asecthr axl is WIhaeol to be*Tittle. 0C has-ale eeeg Ent It In Wale the Is1e sM.wr mute ts:wcurate sd the Inc d publcollun.The sra:Alabon Is sutaect to draye imitate"Mel ndl-e AEVAVI ElPHONE : (BOO) 343 2579 • FAX : (328) 389 :iyti' W' W,ADCABLE.COM 0 dikyam,. infinity solar (4, rasa" C+race Solar Grace Solar )-.•f.Kv.:ra�nr;5rs-Er.1 Grave Solar Grace Solar F.t.-' U 'wc sv5'Eri INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 : - Components — ROOF MOUNTING SYSTEM P INHFINIONETYSOUIR1-800-818COM0598 REVISIONS i_,^I _,r Description Date Rev Iligillb' ' Pitched Roof Mounting System( Flashing Lfee0 � � � •.Main tnat0nal Signature with Seal -..,---------------. "1”...--'---'-'----"-----' � Anodized A16005.1-5 ;\ , W a Benefits itt~irllir\ `nir- ■�1~�wtt �` �� +WaterRrnol4unc6an •- - ■s lrl�ri . � +Eas 1rigaliation 1♦■�lat♦Sa1i y �1lii1i■rill V ! � The parts ran be pre-esnemtlred in the a EMU l Malrrai Project Name& !actors to nave your matelie6 on 11 me on muswaaalins Address 1 site. aims'KIIIIIIIN •flexibtIity and Compatlbllnly ■siil,iilRiil1: Camas instal lora with mo v.of Puler panels ..f—.s .. ,m.., -.__„_,:.._ MIii i1♦If♦i*iii under sir Ma different csndilion M:1 �� ii_=% •Standard llIIN - - SOAOD1.2008 UL ASrNZS 1170and LL Other lrrternntiOnel SINOIure teed Z standards. of LO co co CF> O CI N O ti ly Ground lapI:g 8.ntdu,q minuet I-Q1 G-tlund_1.z CCDD Cr) --- Cogs,. .:-«, (6 Cr-Cit. tl-�.1 A IJJ C.5-t (ic 0 H 0 ,C2) � Cl) f: `' rG µ Pere"` - t i- g H O W O = sr dr. } w 4 ` 10 I ► 1 2 3 4 Rail Rail splice kit Wave piece Clamp kit GS-OA-210D t-S-UR.-Sp ."'.- :.1 GS-41.LD15 /�^'� G3-FK-'31:02 {`�,�/] Uen.nrtan GSFIssedia Flout Sheet Name Anewsdnda vxedzcrow6.0+8a II N5-3050.n. MOUNTING- 2r 235-805m"' DATA SHEET s Shingle Roof(L Feel) * Sheet Size 5 6 7 e t ANSI B •a Inter clamp kit D-module End clamp kit Ground clip 11" X 17° Cs.Ic,.F FS A.nio f � _ , .,•y .f G$-IK-Lp0§ Sheet Number Abenseltm GSt k!*1 C Q �..-r-- Ao"wre�Niva Ntud eordwN 3.90 D V � / s_ _ t i L - �- "v - s g 10 11ii' GS-A-ARO1 Ground log Bonding jumper Flashing hook x IVO Des:or Ism ar_auImerPAW GS r_L CS.C,.,-_.,;.p, ^S-:K-:': t Tin Roof(L Feet) 0 ,rases Grace Solar infinity solar Grace Sala' W M lih�IH.:r.YSTFM INFINITY HOME SOLUTIONS 6405 E MILL PLAIN MAIN PARTS VANCOUVER WA 98661 GS PITCHED ROOF RACKING SYSTEM 1.800-818-0598 INFINITY SOLAR.COMOM Rails And Splice REVISIONS DescrmIon Date Rev Dalmdule can be put into GD Rail from any position via simple installation. Benefits ',Pre-assembled for easy Installation �7 can be put stallatitnn earlier andlncan save ayou time on Sp1e position,This makes ,z _ Signature with Seal x" I 0Various Solution for the different conditions ` " i GD Rail and its accessories can be Installed with the most so18t i panels on the commercial and residential Roof. I *Safety and Reliability �.„ , "� Project Name Address The reciting systems designed by skilled engineers can stand up to the extreme .` weather ppn,plying with ttte ASINZS 1170 and other irtterrlaignal structure toad standards.The main support components have also been tested to guarantee its structure end load-carrying capao ty. GS-DR-Length(Classical) GS-10R-Length(Econorny) w Description: GS Rail 1€1 'Description: GS 1O#Rail U •Technical Information Spec 55x28mm Spec: 4Br.ZBmm w 1— in 5 co c Installation Site Commercial and Residential Roof Et < rn co Z Tilt Angle Flushed with the roof. up to BCdeg Material Aluminum&Stainless steel V OJ O o Building Height up to 26m Gabor Natural&Back { a- Cable can be mounted into the 5#Rail M o Q di uJ Max Wind Speed up to tl0mis Anti-corrosive Anodized ; - Et MO (.7 z H H O= Snow Lad o 1-41CNIm2 Warranty 10 years warranty z1+- - > d Standards ASINZS 1170&DIN 1055 Duration Moe than 20 years .0444 o LLI GS-DR5-Length Mount with the cable GS-CRC-Length + Description: GS 5#Rail -Description: Rail Cap I , _ -Spec: 55x40mm -Spec: 24x tOrrrn Sheet Name r!' � "�" RACKING- .r•. r� DATA SHEET Rail Connection } 4 Grounding Masher;washer __ , ,, _ Sheet Size • d ANSI B 11" X17• " irs . £ - - =.:,'' Sheet Number #, t._'' DS 10 '___ GS-DR-SP Rail Connection GS-DR-SP-GW :, - 11. -' •lescriptlon: Rail Splice -Description: Rail Splice with - -Spec: 150mm grounding washer/washer Spec: 150mm K Xiamen Gone Saar racanclatr Ca.,LM. Xm iaen dv a.G^at a S renalogY Ce.,Ltd. onew.pramaalar.(Om - •.-.---- alWe.Qraaasali.aaen I 0 infinity solar or._ „�'. INFINITY HOME SOLUTIONS AK ►r rasol 6405 E MILL PLAIN .7 1 Rymer TIN r� VANCOUVER WA 98661 a.�dryr++++r PHONE:1-800-818-059B INFINITY SOLAR.COM REVISIONS Descnplbn Dare Rev � __ �„�,� COMPONENTS !fll,.; y; T f _ +'y"' „ a Signature with Seal liktimit, ioi.wik� ilk• >,,, j F eatures „eftm w lLn col W rw]W nwuu ark • Material.S US304 �: ro 44,5:m'��.•-g • Special rib both surface to pierce the aluminum anndization "•� 7216111.11111-\ 4'uu�pry;ma"avow-4-rep, r �*� Cooperated with Inter Clamp to install under the Rail `' ids �s ,mewls 11�1 r1*,1V Project Name& ,*, 1;� �I , Item No. Description it . 4 `_- Actress 1+.��i �i"�i !1� f cs' GS-G-GC Grounding Clip ',, 14 ,..a j4 dexi3id L'> Oh, Pc. OOli ( W • W H 2 CT) D N Features Et -a a' 0-5 z • Conned system to equipment ground conductor 0 0 Q p a . Li SOLAR ARRAY • High Pre assembly � topW ,n GROUNDING SYSTEM = o Q T W Item No. Description ct `, cD z 1— opo GS-C-GrL Grounding Lug a ,tz Introduce • Matenal:AI6005-T5 lay in lug&Stainless Steel Clip&A2-70 bolt P" W GS Grounding Product can be used to bond solar modules to the aluminum rails and the cow..-. - aluminum rails to ground, so that the entire solar system is grounded and safe; Grounding products inculde the stanless steel grounding clip and aluminum grounding lug. which are all designed to comply GS-G-CGL Capper Grounding Lug with the requirement of ASS033,UL467 for bonding or grounding systems. •Material: Copper lay-in lug&Stainless Steel Cie&A2-70 bolt Sheet Name Planning Layout RACKING- to. GROUNDING11 $. Sheet Size GL4AP'cr Win; 0 Grcwrarung cap I Featutrr ANSI B ile MN a i ,ram • Material;Braided Copper Wire&Stainless Steel Clip&A2-70 bolt 11 e X 17e x Grounding Lug 1 • High Pro assembly ti- • Electrically connect spliced Beds Sheet Number L, rirxndirrg Jumper I • Excellent electric cOnductivlty Itern No, Descrption - DS 11 GS-G-EJ Bonding J.irrper 1. 15 wrm0ow 1 infinity •..: CERTIFICATE OF COMPLIANCE INFINITY HOME SOLUTIONS 6405E MILL PLAIN VANCOUVER WA 98661 PHONE 1-800-818-0598 Certificate Number 20181008- E499263 INFINITY SOLAR.COM Report Reference E4 99263-20 1 80 927 REVISIONS Issue Date 2018-OCTOBER-08 D= .,n Dze Rav Issued to: XIAMEN GRACE SOLAR TECHNOLOGY CO LTD Bldg. E No. 195 GaoOi BeiSan Road (GaoQi Industrial Park) Signature with Seal Xiamen Fujian 361006 CHINA. This is to certify that MOUNTING SYSTEMS, MOUNTING DEVICES, Prefect Name& Address representative samples of CLAMPING DEVICES AND GROUND LUGS FOR USE WITH PHOTOVOLTAIC MODULES AND PANELS Mounting Systems for Use with Photovoltaic Modules and Panels, Model GS-PR-10R. w U 00 Have been investigated by UL in accordance with the o N Standard(s) indicated on tills Certificate. w m 00 a cc Q z o H o O J Standard(s)for Safety: UL2703 "Standard for Mounting Systems, Mounting cr p ¢ LL W Devices, Clamping/Retention Devices, and Ground Lugs for cc 0 0 z use with Flat-Plate Photovoltaic Modules and Panels", ¢ o ~ o a Additional Information: See the UL Online Certifications Directory at w www_ul.com'database for additional information Only those products bearing The UL Certification Mark should be considered as being covered by UL's certification and Follow-Up Service. Sheet Name Look for the UL Certification Mark on the product. RACKING- CERTIFICATION diedieftilig 4:111) Sheet Size ANSI B 11" X17" Sheet Number DS 12 S Wm.Nahnolikalr. Mob Mato C_ ._Pm.ran -._-.- W.CLC ►nr*eaaren N eraosmtlRwn,.M*,l uL Nal.antes aft acacia se Iamlf U.0 lU1la enr+.e,aeal eea,=.IaL.,a saerra.era Gala i•B W N.GYlara'Mown IYee.sYf,.dSMXW.a.a'Mu.aeleoeaW Page 1 di Created by UL Document Assembler 2018-10-2422:15''fWF _tS'rtn