Plans (5) 16'xa'UNDER-FLOOR VENT
16x28 CRAWL SPACE ACCESS INSTALL IN RIM JOIST
OPENING WITH WELL
r T - DC
, :.A L..-;,+ SIMPSO6 EACH
SEAM.TYPICAL OF BEAM.TYPICAL W
r , m
I7 (E)DBL.2x8 r r r r r (E)DBL.2.8 r7I r—I r (E)DBL.2.5 I—7 16522 UNDER-FLOOR VENT Er G
E
LJ LJ LJ LJ LJ LJ LJ LJ Y(N)4x6 _r-- INSTAL.IN NM JOIST
`z c
m $ zt
0 6
I— ��� G r
(�DXL.zxa r —I r 71 (E1 DBL.zxa r 1 r (XI DaL.2x5 J (N)4x6 .1
L J L J L J L J L J L J L J L J ��',,,FFF ` al
2x6 TNG SUB-FLOOR PERPENDICULAR
c
OR AT 45-DEGREE ANGLE TO NEW BEAMS 0
al
L (N14x6 G
I r 7 (El DBL.2,5 r—I r 7 r 7 (E)DBL.2x8 I 16'xa'UNDER-FLOOR VENT
L 1 LJ LJ L j J LJ LJ ?' INSTALL IN RIM JOIST -
__f— r-- �
fl 7 (E)DBL.2x5 77 r—I r 7 co DBL.2x8 r 7 w41-e' / SIMPSONHHUS96 EACH
L J L J L J L J L J END OF BEAM,1-881cAL
r1\ L 1- 77 (F)DBL2xa 77 r-1 r7 (E)DBL2A8 rJ
FOUNDATION LJ LJ LJ LJ LJ
L J
E 7 IsI ',
L L
••
tio FOUNDATION 4 FLOOR FRAMING PLAN ,[ Ji I- cn (N
Approved plans 11_011 11
�, >1 .� Q
4 UPPER PORTION OF EXISTING
WALL TO REMAIN
r_---;-.hall__be,on job Set'' tu)axa POST p6t.+r
..:�.C. 2x4 WALL WAR 151N5UTATION G.�f� �e�
ROOF EfHAUST VENT EACH BAY xJ�� 1s, V /r ' I ' �/
r — —� WITH RAFTERS
30 HIGH--DENSITY INSULATION \` l I�f I()
IZJ 1 1 I 1 I L— I 1 L O}'CNA LING 10 C'ROOF SHEATHING E D
- iu / 2x6 WALLWIR21 INSULATION 8d NAILING�6'EDGES AND 12'FIELD O ui
L
RAFTER TO PLATE(4)ad TOE NAILS'LXITH
¢I SIMPSON ASS EACH SIDE
ui CLASS A COMPOSITION ROOF O U Ct
SHINGLES ER ROOF MEMBRANE
NEW 4X 12 BEAM(SPANS NEW ""'"""' IL''V
N N OPENING ONL'n �^
OFFICE COPY Jq It. . . i t t x i _ rn
/I �� I ) ` I+nnF VYN INTAKE(AIR SPACE)
/ I � COVER WIT METAL T COS
H(OR USE/
RL
BIRD BOX 9 VENT BL BETWEEN Q J l—
RAFTERS CO N
TE
City _ / \ ~ C5DW5 DOUBLE
TH adPNALNG 6"AT'iCJJ EDGES AND 12'1N FIELD
N r
Approved M)4x4 POST ` F ��
roved P r� J NEW 2x4 STUDS INSULATION 16'O C
Ily ill's ���� � �� \ REMOVE EARING RIORWAIL C WITHR-S L-PLO
2.6 WALL WB21 INSULATION BEARING WALL
_ NEW 2x6 T6G SUB-FLOOR
"-'� NEW 4x6 MAIN PER PLAN
(E)2x6 TNG SUB-FLOOR C WITH R-25 INSULATIONrY\S
D�� - SIMPSON 1HU546 HANGER
' _ ._� _.. .i _a "; EACH END OF BEAM
G\11vc.
1 1 ) it Nry
7,0
Ce
Pi CC
__, ,
,- • „:._ . . ,.
.ce g — ,cc
/ \ \• ,A MAII :
\/ • /\ ,\��/� 94 DOWEL d46.Oc, i m o g m m O
CO
___. .. ��wU\� /A]-� //> \ \ \/ ALTERNATE BENDS . g 6 0 R
r _- EXISTING POST 6 BEAM FLOOR % ``• a� x' .� o m a a Q�
FRAMING TO REMAIN _ N \ x Ei'1/ WALLEPER TPLAN,3,000 P S!.CONCRETE 2 S
\ EXISTING FOOTING 6 FOUNDATION ` 6 l\/A pq CONTINUOUS.hP.
MIN.6-MIL VAPOR DARNER,LAP MIN.IV, i"-/
®� EXTEND MIN.I2'UP STEM WALLS
'.0.—.,
Z.
5-5
IDCEILING AND ROOF FRAMING PLAN . SECTION AT NEW ADDITION FRAMING PLAN
I n— , 51 . 1
2-