HomeMy WebLinkAboutPlans RECEIVE AERIAL SITE VIEW JURISDICTION CODES AND STANDARDS L' 1 ,� .�4 it IIII 8 2022 GOVERNING CODES x6. ION I. ALL WORK SHALL COMPLY WITH: di ' f # 2021 OREGON ELECTRICAL SPECIALTY CODE(OESC)„...,,,,, CITY OF TIGARD <.� ' `- w 2019 OREGON STRUCTURAL SPECIALTY CODE(OSSC) BUILDING DIVISION 4.� 1 .9....111 - s4 �C CODE(ORSC) 2021 OREGON RESIDENTIAL SPECIALTY 2018 INTERNATIONAL FIRE CODE(IFC) 4 2021 OREGON PLUMBING SPECIALTY CODE Ai! AND ALL STATE AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING CODES. 10 ` CONFIDENTIAL-THE INFORMATION 4• - HEREIN CONTAINED SHALL NOT BE USED�, LIABILITY 4,1J 11 11 SITE CLASSIFICATION NOTES,OSHA REGULATION FOR THE BENEFIT OF ANYONE EXCEPT ION 11"1""w": �F The City of Tigard and its DEVELOPER,LLC NOR SHALL IT BE f nIIYYY. DISCLOSED IN WHOLE OR IN PART TO rx . OCCUPANCY CLASS: SFR employees shall not be CONSTRUCTION CLASS: V-B OTHERS OUTSIDE RECIPIENTS 24/7400 g (''� ZONING TYPE: RESIDENTIAL responsible for discre ncles ORGANIZATION,EXCEPT IN CONNECTION _ HeatiI'�q 8y C0 WITH THE SALE AND USE OF THE which may eppe="i-herein. RESPECTIVE EQUIPMENT,WITHOUT THE I. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS WRITTEN PERMISSION OF ION DEVELOPER, ° 2. THIS PROJECT HAS BEEN REVIEWED AND WILL NOT DIRECT CONCENTRATED SOLAR RADIATION OR GLARE LLC. ONTO NEARBY PROPERTIES OR ROADWAYS. -� x ,r SCJ 3. FOR PROJECTS SUBMITTED FOR PRESCRIPTIVE REVIEW,ROOF ATTACHMENTS SHALL BE SPACED NO GREATER •' 1 THAN 24"ON CENTER IN ANY DIRECTION WHERE LOCATED WITHIN 3'OF A ROOF EDGE,HIP,EAVE,OR RIDGE OSSC 3111.3.5.3 ITEM 3.2 NABCEP ,. �� q , - ELECTRICAL CRITERIA,NOTES y ;n CERTIFIED M �-- TEMPERATURE SOURCE: ASHRAE 'Approved }°°la 4 e. C WEATHER STATION: PORTLAND HILLSBOR0 PV INSTALLATION V :. � I EXTREME MIN. TEMPERATURE: -8 shall be on job site. PROFESSIONAL ASHRAE 0.4%HIGH TEMP: 37 `,' z ��� SCOTT A GURNEY #PV-0117719-015866 .' ° 7 I. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. : 1 ;,. , r ION DEVELOPER,LLC 2. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN PROVIDED)IN 4801 N UNIVERSITY AVE#900 PROVO, UT a a ACCORDANCE WITH NEC 110.14(D)ON ALL ELECTRICAL. 84604 `" :T . 3. PV MODULE CERTIFICATIONS WILL INCLUDE ULI703,IEC61646,IEC61730. 888.781.7074 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. DAVID STANLEY CONRAD 5. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL C -ELECT CAL C NTRACTOR t - M BE PROVIDED AS PER SECTION[NEC 110.26]. RICI5240 �.; « STRUCTURAL CRITERIA,NOTES *itAsue:.,. DESIGN LOAD STANDARD: ASCE 7-16 * _ 't, WIND EXPOSURE CATEGORY: B CITY OF TIGARD ` WIND SPEED(3-SEC GUST): 96 MPH O GROUND SNOW LOAD: 36 PSF REVIEWED FO CODE COMPLIANCE — ,"".. DESIGN ROOF SNOW LOAD: 25 PSF N SEISMIC DESIGN CATEGORY: D Approved: [V] 0 W N SEISMIC RISK FACTOR: II ��}j � � �, OTC: [ ] a = Permit#: �1( 'iiol 0 `39% z `� adiminAddress: `$397 S1 J �rjrr- Lin < N v) c) OFFICE COPY suite #: a o a , ,. a ',, 4 z By: M Date: �o�UJ/ZZ w w z a 9 w ( Q w OU O — U ae N CO W _ a N N 4 O Q O O Li_ 0 + W Z N Q N W Y rn �iSCOPE OF WORK H o °) _ o o SHEET LIST v, w co I- " K; DRAWING BY INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM G-I COVER SHEET ENPHASE ENERGY V-2 SITE PLAN (AD. LIB) 3.8 KW DC & 2.9 KW AC PHOTOVOLTAIC SOLAR ARRAY S-3 ROOF PLAN ,p PROF DATE S-4 STRUCTURAL DETAILS . VALIDITY OF PERMIT .\<c.5 FSS/ 20-SEP-2022 S-5 STRUCTURAL CALCULATIONS & NOTES ' ' THE ISSUANCE OFA PERMIT ��� �� • I RfF O PV MODULES: (10) SILFAB SOLAR SIL-380 HC 20211101 �. .Q 'L E-6 ELECTRICAL DETAILS (LINE DIAGRAM) BASED ON CONSTRUCTION 9r PROJECT ID INVERTER(S): (10) ENPHASE IQ8PLUS-72-2-US E-7 ELECTRICAL CALCULATIONS & NOTES DOCUMENTS AND OTHER / 950P 007RZC E-8 ELECTRICAL LOAD CALCULATIONS (AD. LIB) DATA SHALL NOT PREVENT OREGON ROOF TYPE: COMPOSITION SHINGLE - I LAYER(S) E-9 ELECTRICAL LABELS & LOCATIONS THE CODE OFFICIAL FROM SHEET NAME PV MOUNTING HARDWARE: ECOFASTEN CLICKFIT E-10 ELECTRICAL DIRECTORY PLACARD (AD. LIB) REQUIRING THE CORRECTION `/'44/ II 20ti� COVER SHEET OF ERRORS. ORSC ?05 ^ q �c, 09/21/2022 4N RO`N ' SHEET NUMBER REVISON EXPIRES:12/31/24 G-I 0 • SITE NOTES: I. FOR PROJECTS SUBMITTED FOR PRESCRIPTIVE REVIEW, ROOF ATTACHMENTS SHALL BE SPACED NO I 0 N GREATER THAN 24" ON CENTER IN ANY DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, HIP, RSI EAVE, OR RIDGE OSSC 3111.3.5.3 ITEM 3.2 FOR ANY METER UPGRADES, ENSURE THAT THE + _ -THE - UTILITY METER IS LOCATED WITHIN 10FT OF THE ,4 HEREEINCONFIDENTIAL CONTAINED SHALL NOT BEION USED FRONT/STREET-SIDE OF THE HOUSE. PLEASE ADD A 4 FOR THE BENEFIT OF ANYONE EXCEPT ION LABEL SHOWING THE DISTANCE FROM THE FRONT ' DEVELOPER,LLC NOR SHALL IT BE i DISCLOSED IN WHOLE OR IN PART TO CORNER OF THE HOUSE. IR' IR' +i OTHERS OUTSIDE RECIPIENTS n , _ ORGANIZATION, EXCEPT IN CONNECTION + WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE re + WRITTEN PERMISSION OF ION DEVELOPER, O + LLC. I� + u� R' +. n + K-IABC'El + O CERTIFIED + PV INSTALLATION + I I PROFESSIONAL IR. �,� �I SCOTT A. GURNEY n + / ' #PV-0117719-015866 0 + ION DEVELOPER, LLC C- O.-. + O 4801 N UNIVERSITY AVE#900 PROVO, UT X + 84604 888.781.7074 + I'-0" _+ DAVID STANLEY CONRAD + C-ELECTRICAL CONTRACTOR + C1524 0 O Z U N w C) N z D U) \\ U w�` Q I 1 z O N Et N J (n'_ U U Z Q ct CL DISH I— w o o 0 co Li j �CO� pPROFF C _ Q s\, \ GI Nee- /ma 0 �c' y a0 z4 995OP I- off ( o o °C). (7 (n w ... Tr) FRONT OF HOME cOREGONDRAWING BY 8397 SOUTHWEST DURHAM LANE N /12pfl� ENPHASE ENERGY SCALE: I/8" = I' 0" N RO\S\- 09/21/2022 DATE 0' 2 4' 8' 16' 20-SEP-2022 EXPIRES:12/31/24 SYSTEM LEGEND (N> (N> O ROOF SECTION ROOF PV MODULE PROJECT ID (N) PV COMBINER PANEL d(N) (N) JUNCTION BOX s# SUNEYE LOCATION SECTION OTY AZIMUTH PITCH TSRF 007RZC CRITERIA AND RSI 10 271 33 78% ((Es" (E) UTILITY METER / 0(N) (N) PV LOAD CENTER (N) (N) AC DISCONNECT .�:::i FIRE SETBACK SPECIFICATIONS KM.i MAIN SERVICE PANEL LC ACD (VISIBLE-OPEN LOCKABLE LABELED DISCONNECT) J (E) (E) MAIN SERVICE PANEL (N' (N) PV PRODUCTION DC (N) MICROINVERTER ROOF PLAN SHEET NAME MAIN QJ METER AC (N) PV MODULE SHEET NUMBER REVISON SUB (E) SUBPANEL (N) (N) DC-DC / STRING (N) (N) DC DISCONNECT S-3 0 NVERTER RACKING INSTALLATION SCHEDULE AND STRUCTURAL CRITERIA /-PV MODULE PV RACKING SPAN AREA TAG SPAN PV MOUNTING RAIL I 0 N RACKING: ECOFASTEN CLICKFIT RAIL -PORTRAIT-MODULE ORIENTATION /� 1 / 1 1j I PORTRAIT RACKING TYPE: RAIL X-SPACING P-XI 48 IN. O.C. MAX. M ORIENTATION STANDOFF: CLICKFIT L-FOOT X-CANTILEVER P-X2 16 IN. MAX. NJ STANDOFF TYPE: L-FOOT&FLASHING Y-SPACING P-YI 37.4 IN. MIN. -45.3 IN. MAX. 5/16"X 3-I/2"ZINC PLATED PV ARRAY DETAIL, FRONT VIEW P-X2— P-XI _ FASTENER: STEEL LAG SCREW Y-CANTILEVER P-Y2 12.1 IN. MIN. - 16 IN. MAX. CONFIDENTIAL-THE INFORMATION SCALE: 3/8" = 1'-0" 1 14 t LANDSCAPE HEREIN CONTAINED SHALL NOT BE USED iri> ORIENTATION FOR THE BENEFIT OF ANYONE EXCEPT ION STRUCTURAL RAIL-LANDSCAPE-MODULE ORIENTATION .�1 —� DEVELOPER,LLC NOR SHALL IT BE ROOF TYPE: COMPOSITION SHINGLE X-SPACING L-XI 48 IN. O.C. MAX. DISCLOSED IN WHOLE OR IN PART TO ROOF SHEATHING TYPE: 7/16"OSB X-CANTILEVER L-X2 16 IN. MAX. —L-X2 L-XI OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION STRUCTURE TYPE: MANUFACTURED WOOD TRUSS Y-SPACING L-YI 21.1 IN. MIN. -25.1 IN. MAX. WITH THE SALE AND USE OF THE RAFTER SIZE: 2x4 Y-CANTILEVER L-Y2 7.9 IN. MIN. -9.8 IN. MAX. RESPECTIVE EQUIPMENT,WITHOUT THE PORTRAIT WRITTEN PERMISSION OF ION DEVELOPER, RAFTER SPACING: 24 LLC. ORIENTATION ARRAY PARAMETERS TOTAL ROOF AREA(SQ. FT.) 1416 P-Y2 �ABCP TOTAL PV MODULE AREA(SQ. FT.) 197 `� %PV MODULE ROOF COVERAGE 14% \ L-Y2 CERTIFIED LANDSCAPE ORIENTATION PV INSTALLATION P YI ��' PROFESSIONAL �.5 ,, /� SCOTT A. GURNEY r #PV-0117719-015866 PV ARRAY DETAIL, SIDE VIEW ION DEVELOPER,LLC SCALE: 3/8" ' 1' 0" , 4801 N UNIVERSITY AVE#900 PROVO,UT / 84604 /' 888.781.7074 - DAVID STANLEY CONRAD L-YI RACKING ATTACHMENTS TO BE STAGGERED BY SHIFTING EACH C-ELECTRICAL CONTRACTOR SUBSEQUENT ROW OF ATTACHMENTS ONE RAFTER OVER CI524 TO DISTRIBUTE LOAD ACROSS ALL FRAMING MEMBERS UNDER PV ARRAY. O (4 W O PV MODULE Q U _ 1 2 O N / <I 141 r U ✓ N J i 0 � U G J CLICKFIT RAIL z o rn N a 0 w U o aO 2 V 6 CLICKFIT L-FOOT o Y H o COos Q U �s� (E) COMP SHINGLE 1111111 _El Li_ CI 0 Z N. Q w I. ROOF MEMBRANE o w o o co rri DRAWING BY COMP SHINGLE FLASHING ENPHASE ENERGY 2i" MIN. ��9 PROPeo DATE DEPTH 5/16" ZINC PLATED STEEL �� aG I N£F `r/0 20-SEP-2022 LAG SCREW WITH 2-1/2" ,v y MIN. EMBEDMENT IN TO 9 950P PROJECT ID (E) ROOF RAFTER 007RZC OREGON OSTANDOFF DETAIL ,i �, SHEET NAME SCALE: 3" = I' O" 4N 11, 20�' 9� Fy 09/21/2022 STRUCTURAL DETAILS qN RO`N� SHEET NUMBER REVISON EXPIRES:12/31/24 S_4 0 /�Si 2D22 oo3S� , PV SYSTEM STRUCTURAL SPECIFICATIONS AND CALCULATIONS PV SYSTEM EQUIPMENT SPECIFICATIONS DESIGN LOCATION AND SITE SPECIFICATIONS GRAVITY LOAD / FRAMING CALCULATIONS MODULE MANUFACTURER / TYPE SILFAB SOLAR SIL-380 HC 20211101 JURISDICTION DEAD LOAD (PSF) RSI I 0 N SOLAR MODULE WEIGHT (LBS) 43 CITY OF TIGARD ROOF MEMBRANE COMPOSITION SOLAR MODULE LENGTH (IN.) 69.4 STATE OREGON SHINGLE 4'0 SOLAR MODULE WIDTH (IN.) 40.8 ADOPTED LOAD STANDARD ASCE 7-16 SHEATHING 7/16"OSB 1.7 SOLAR MODULE AREA(SQ. FT) 19.7 OCCUPANCY/ RISK CATEGORY II PV RACKING ECOFASTEN CLICKFIT BASIC WIND SPEED (MPH (3-SEC GUST)) 96 CONFIDENTIAL-THE INFORMATION PV RACKING TYPE RAIL WIND EXPOSURE CATEGORY B HEREIN CONTAINED SHALL NOT BE USED MANUFACTURED FOR THE BENEFIT OF ANYONE EXCEPT ION PV ROOF ATTACHMENT CLICKFIT L-FOOT GROUND SNOW LOAD(PSF)(PG) 36 WOOD TRUSS - TOP DEVELOPER,LLC NOR SHALL IT BE 5/16"X 3-1/2" ZINC PLATED STEEL LAG FRAMING CHORD 2X4 @ 24 IN. 1.0 DISCLOSED IN WHOLE OR IN PART TO PV ROOF ATTACHMENT FASTENER SCREW BASE ELEVATION (FT) 153 O.C. -DF #2 @6 FT. OTHERS OUTSIDE RECIPIENTS SPAN ORGANIZATION,EXCEPT IN CONNECTION MAX RACKING DEAD LOAD (PSF) 0.8 WITH THE SALE AND USE OF THE SOLAR MODULE DEAD LOAD (PSF) 2.18 DESIGNED ROOF SNOW LOAD CALCULATIONS ASCE 7-16 (C&C) RESPECTIVE EQUIPMENT,WITHOUT THE TOTAL PV ARRAY DEAD LOAD(PSF) 2.98 SLOPED ROOF SNOW LOAD (PSF) EQN. 7.4-I WRITTEN PERMISSION OF ION DEVELOPER, LLC. = PS = (Cs)(0.7)(CE)(CT)(Is)(PG) TOTAL ROOF DEAD LOAD (PSF) 6.7 PV SYSTEM STRUCTURAL SPECIFICATIONS EXPOSURE FACTOR (CE) = 1.0 TABLE 7.3-I ADJUSTED TO SLOPED ROOF (PSF) 8.1 STRUCTURE TYPE - ROOF SHAPE INHABITED -GABLE / FLAT ROOF THERMAL FACTOR (CT) = 1.0 TABLE 7.3-2 NABCEP MIN. ROOF SLOPE (DEG.) 33 IMPORTANCE FACTOR (Is) = 1.0 TABLE 1.5-2 PV ARRAY ADJ. TO ROOF SLOPE (PSF) 3.6 MEAN ROOF HEIGHT (FT.) 23 SLOPE FACTOR (Cs) = 0.9 FIG. 7.4-I ROOF LIVE LOAD < ROOF SNOW LOAD (PSF) 25.0 CERTIFIED PORTRAIT ATT. SPACING (IN. O.C.) 48 Ps(PSF) = 25 OK TOTAL LOAD (PSF) 36.6 PV INSTALLATION LANDSCAPE ATT. SPACING (IN. O.C.) 48 #OF ATTACHMENT POINTS 25 RAFTER/ TOP CHORD MEMBER PROPERITES DF #2 -2x4 PROFESSIONAL MASECTION MODULUS (S)(IN"3) ' . X. POINT LOAD (LBS /ATT.) 3.06 14.6 I SCOTT A. GURNEY #PV-0117719-015866 MAX. TOTAL PV DEAD LOAD TO RAFTER (LBS) 14.6 MOMENT OF INERTIA(I)(IN"4) 5.36 TOTAL LOAD ON MEMBER(W)(PLF) 73.3 ION DEVELOPER,LLC DESIGN WIND PRESSURE AND CONNECTION UPLIFT CALCULATIONS ASCE 7-16 (C&C) MAX. MEMBER SPAN (L)(FT) 6 4801 N UNIVERSITY AVE#900 PROVO, UT 84604 DESIGN WIND PRESSURE (PSF) = P = QH(GCP)(YE)(YA) EQN. 29.4-7 MODULUS OF ELASTICITY (E)(PSI) 1600000 888.781.7074 VELOCITY PRESSURE (PSF) =OH = 0.00256(KH)(KzT)(KD)(KE)(V"2) EON. 26.10-I SHEAR (Fv) (PSI) 180 TERRAIN EXPO. CONSTANT(A) = 7 TABLE 26.11-I ARRAY EDGE FACTOR (YE) = I TABLE 26.13-I AREA(A)(IN"2) 5.25 DAVID STANLEY CONRAD TERRAIN EXPO. CONSTANT(ZG)(FT) = 1200 TABLE 26.11-I GROUND ELEVATION FACTOR (KE) = 0.99 FIG. 29.4-8 C-ELECTRICAL CONTRACTOR VP EXPOSURE COEFF.(KH) = 0.70 EQN. C26.10-I EON. 26.10-I MAX BENDING STRESS CHECK (FB)(CD)(CF)(CR) C1524 TOPOGRAPHIC FACTOR (KzT) = 1.0 EON. 26.8-I OH(PSF) = 13.96 BENDING (Fe)(PSI) 900 WIND DIRECTIONALITY FACTOR (KD) = 0.85 TABLE 26.6-I LOAD DURATION FACTOR (CD) 1.15 SIZE FACTOR (CF) 1.50 UPLIFT DOWNWARD REPETITIVE MEMBER FACTOR (CR) 1.15 I GABLE ROOF 27°< 0 545° ZONE I ZONE 2R ZONE 2E ALL ZONES FIGURE 30.3-2D ALLOWABLE BENDING STRESS (PSI) 1785.4 0 RAIL -PORTRAIT MODULE ORIENTATION 48 IN. O.C. 48 IN. O.C. 48 IN. O.C. 48 IN. O.C. _ SOLAR PANEL PRESSURE EQ. FACTOR(YA) = 0.80 0.80 0.80 0.80 ACTUAL BENDING STRESS(PSI) _ (wL"2)/(8(S)) 1292.0 N EXTERNAL PRESSURE COEFF. (GCP) = -1.8 -2.0 -3.2 0.9 72% OK W N ASD PRESSURE (0.6P)(PSF) _ -12.06 -13.40 -21.44 16.75 Q U U7 TRIBUTARY AREA(SQ. FT) = 11.6 11.6 8.7 MAX DEFLECTION CHECK- TOTAL LOAD UNIFORM DISTRIBUTED O cV MAX. UPLIFT(0.6D+0.6P) (LBS) _ -118.8 -134.3 -170.5 ALLOWABLE DEFLECTION L / 180 co c' U Q ''n Q 0.400 IN. Q0 N --I0 RAIL -LANDSCAPE MODULE ORIENTATION 48 IN. O.C. 48 IN. O.C. 48 IN. O.C. 48 IN. D.C. ACTUAL MAX DEFLECTION (W)(L)"4 / 185(E)(I) D n =cn U SOLAR PANEL PRESSURE EQ. FACTOR(YA) = 0.80 0.80 0.80 0.80 0.103 IN. Z 0 U J U) Q H- CC U EXTERNAL PRESSURE COEFF. (GCP) _ -1.8 -2.0 -3.2 0.9 26% OK 0 z Q co W N ASD PRESSURE (0.6P)(PSF) _ -12.06 -13.40 -21.44 16.75 MAX DEFLECTION CHECK-LIVE LOAD Q W O OJ O U TRIBUTARY AREA(SQ. FT) = 6.80 6.80 5.10 ALLOWABLE DEFLECTION L / 240 Z D = W W •(NJ ' MAX. UPLIFT (0.6D+0.6P) (LBS) _ -69.8 -79.0 -100.2 0.3 IN. OO D p Q ,-.I" C. ^ ROOF ATTACHMENT FASTENER CHECK NDS 12.2 ACTUAL MAX DEFLECTION (W)(L)"4 / I85(E)IN U. < O 0 -J z 0 CLICKFIT L FOOT-5/I6"X 3 I/2"ZINC PLATED 0.089 IN. UJ Z N. Q W tri STEEL LAG SCREW MANUFACTURER MAX. UPLIFT CAPACITY=359.6 LBS 30% OK I- O re) U O O (/) (/) co 1- v v to LAG SCREW WITHDRAWAL DESIGN VALUE (LBS) =W = 1800(G"3/2)(D"3/4) 12.2.1 MAX SHEAR CHECK ROOF ATTACHMENT FASTENER (D) = 5/16 IN. LAG SCREW LUMBER SPECIFIC GRAVITY (G)= 0.5 TABLE 2.3.2 ALLOWABLE SHEAR Fv(A) DRAWING BY FASTENER QTY PER ATTACHMENT = I LOAD DURATION FACTOR (CD) = 1.6 TABLE I2.3.3A 945 LBS. ENPHASE ENERGY FASTENER EMBEDMENT DEPTH (IN.) = 2.5 PRYING COEFFICIENT = 1.4 ,iL_p PROF-4- ACTUAL MAX SHEAR (w)(L)/2 WITHDRAWAL DESIGN VALUE(W)(LBS / IN.) = 266.0 \'`� G'N�, vs�o 220 LBS. DATE LAG SCREW WITHDRAWL CAPACITY(LBS) = 760.0 �� <`� F4, 23% OK 20-SEP-2022 MAX. ATT. WITHDRAWAL CAPACITY(LBS) = 359.6 > 170.5 MAX UPLIFT DEMAND (LBS) OK 9 i 950P r PROJECT ID OREGON 007RZC 11 ''4N „ 20'Ll'_1 SHEET NAME �qN R0W�,4.\ 09/21/2022 STRUCTURAL CALLS EXPIRES:12/31/24 SHEET NUMBER REVISON S-5 0 CONDUCTOR AND RACEWAY SCHEDULE TAG QTY SIZE-# TYPE DESIGNATOR I/V TAG QTY SIZE-# TYPE DESIGNATOR I/V TAG QTY SIZE-# TYPE DESIGNATOR I/V TAG QTY SIZE-# TYPE DESIGNATOR I/V IO (I) 10 AWG THHN/THWN,CU. BLACK (LI) 12.14 AC (MAX) 3 (I) 10 AWG THHN/THWN, CU. BLACK (LI) 12.IA AC (MAX) 2 (I) 10 AWG 2C,NM-B W/G, CU. (LI, L2, EGC) 12.IA AC (MAX) 1 (I) 12 AWG 2C,TC-ER,CU. (LI,L2) 12.IA AC (MAX) (I) 10 AWG THHN /THWN, CU. RED(L2) 240V AC (I) 10 AWG THHN/THWN, CU. RED(L2) 240V AC FREE AIR 240V AC (I) 6 AWG SOLID BARE CU. (EGC) 240V AC (I) 10 AWG THHN /THWN, CU. WHITE(N) (I) 10 AWG THHN/THWN, CU. GREEN (EGC) (I) 3/4 IN. EMT OR FREE AIR (RACEWAY) ION (I) 10 AWG THHN /THWN, CU. GREEN (EGC) (I) 3/4 IN. EMT (RACEWAY) (I) 3/4 IN. EMT (RACEWAY) EXTERIOR EXTERIOR INTERIOR EXTERIOR CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE ELECTRICAL LINE DIAGRAM DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE (E)UTILITY (E)200A MAIN SERVICE PANEL LOAD-SIDE SOURCE CONNECTION (N)ENPHASE IQ COMBINER 3 RESPECTIVE EQUIPMENT,WITHOUT THE METER (E)200A/2P MAIN DISCONNECT BUSBAR PLUG-IN TYPE BREAKER (PV CIRCUITS ONLY) WRITTEN PERMISSION OF ION DEVELOPER, (NEC 705.12) LLC. (10)SILFAB SOLAR SIL-380 HC 20211101 PV MODULE(S) /1 SECONDARY POWER INTEGRATED UL 1703 LISTED SOURCE(PV OCPD)TO I5A/2P MAX TO 10 ENVOY NABCEP ' BE LOCATED AT (IS)ENPHASE IQ8PLUS-72-2-US MICROINVERTER(S)[240V] (E)200A/2P GATEWAY UL 1741 LISTED OPPOSITE END R ° CERTIFIED F BUSBAR FROM PRIMARY \, n '° SOURCE(MAIN OCPD) to O (E)LOADS (NEC 705.12) (N)JUNCTION BOX (N)JUNCTION BOX PV INSTALLATION --. .1)- (OPTIONAL-FOR (OPTIONAL-FOR PROFESSIONAL ° CONDUCTOR SPLICE) CONDUCTOR SPLICE) 20/240 VAC S• SCOTT A. GURNEY 60HZ (N)20A/2P n (N)20A/2P _ (I) r #PV-0117719-015866 SINGLE PHASE _ gLI LI CIRCUIT ION DEVELOPER,LLC UTILSERVITYICE N� tl N °--~ \— OF 10 ����� 4801 N UNIVERSITY AVE#900 PROVO, UT EGC I-v ----ame-- j EMI 1 MODULES 84604 888.781.7074 GO DAVID STANLEY CONRAD 0 O 0 0 C-ELECTRICAL CONTRACTOR LI Lz OF. C1524 (E)GROUNDING (ELECTRODE SYSTEM 0 (V Li NZ Z N a D W = 0 N co (V U rr) N. Q CC N III � U Z o Os J N Q ELECTRICAL LINE DIAGRAM NOTES • a o 0 Os D _ m 40 N I— Q Q O Z O„ 0 W Z 2 LLJ Q ^ Q ( W rri Z ~ O U o o co DRAWING BY ENPHASE ENERGY DATE 20-SEP-2022 PROJECT ID 007RZC SHEET NAME ELEC. LINE DIAG. SHEET NUMBER REVISON E-6 0 PV SYSTEM ELECTRICAL SPECIFCATIONS AND CALCULATIONS DESIGN LOCATION AND TEMPERATURES RACEWAY / CONDUCTOR CALCULATIONS TEMPERATURE DATA SOURCE ASHRAE MICROINV. TO JUNCTION BOX (I) I 0 N - STATE OREGON MAX INVERTER OUTPUT CIRCUIT CURRENT = 12.1 A AC JURISDICTION CITY OF TIGARD MAX CURRENT X125%= 15.0 A AC WEATHER STATION PORTLAND HILLSBORO PER NEC 690.8(B)(I)(W/OUT CORRECTION FACTORS) ASHRAE EXTREME LOW TEMP (°C) -8 CONDUCTOR SIZE / INSULATION / TYPE - 12 AWG 2C, TC-ER, CU. CONFIDENTIAL-THE INFORMATION ASHRAE 0.4% HIGH TEMP (°C) 37 HEREIN CONTAINED SHALL NOT BE USED CONDUCTOR AMP. RATING @ 90°C = 30 A FOR THE BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE DESIGNED MAX. SYSTEM VDROP / VRISE 2.00% AMB. TEMP. AMP. CORRECTION = NOT APPLIED DISCLOSED IN WHOLE OR IN PART TO ADJUSTED AMPACITY COMPLIANCE (A) = 30 > 15.0 OK OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION PV MODULE SPECIFICATIONS SILFAB SOLAR SIL-380 HC 20211101 RACEWAY SIZE / TYPE = 3/4 IN. EMT OR FREE AIR WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE RATED POWER (PMAX) (W) 380 CROSS-SECTIONAL AREA OF CONDUCTOR(S) / CABLE(S)(IN."2) = 0.142 IN.2 WRITTEN PERMISSION OF ION DEVELOPER, MAXIMUM POWER VOLTAGE (VMP) 35.32 CROSS-SECTIONAL AREA OF RACEWAY(IN."2) = 0.533 IN.2 LLC. MAXIMUM POWER CURRENT (IMP) 10.77 % ALLOWABLE RACEWAY FILL (NEC CHAPTER 9, TABLE I) = 53% > 27% OK OPEN CIRCUIT VOLTAGE (VOC) 42.17 NABCEP SHORT CIRCUIT CURRENT (ISC) 11.36 JUNCTION BOX TO JUNCTION BOX (2) PMP/VMP TEMP. COEFFICIENT -0.36 MAX INVERTER OUTPUT CIRCUIT CURRENT = 12.1 A AC CERTIFIED VOC TEMP. COEFFICIENT -0.28 MAX CURRENT X125% - 15 A AC PV INSTALLATION SERIES FUSE RATING 20 PER NEC 690.8(B)(I)(W/OUT CORRECTION FACTORS) PROFESSIONAL ADJ. MODULE VOC @ ASHRAE LOW TEMP 46.1 CONDUCTOR SIZE / INSULATION / TYPE = 10 AWG 2C, NM-B W/G, CU. S.. /1 SCOTT A. GURNEY #PV-0117719-015866 ADJ. MODULE VMP @ ASHRAE 2% AVG. HIGH TEMP 29.7 CONDUCTOR AMP. RATING @60°C = 30 A ION DEVELOPER,LLC # OF CONDUCTORS IN RACEWAY CORRECTION = NOT APPLIED 4801 N UNIVERSITY AVE#900 PROVO,UT INVERTER SPECIFICATIONS ENPHASE IQ8PLUS-72-2-US AMB. TEMP. AMP. CORRECTION = NOT APPLIED 84604 888.781.7074 TYPE MICROINVERTER ADJUSTED AMPACITY COMPLIANCE (A) = 30 > 15.0 OK MAX. OR RECOMMENDED MODULE POWER (W) 440 RACEWAY SIZE / TYPE = FREE AIR DAVID STANLEY CONRAD XIMUM INPUT DC OPEN-CIRCUIT VOLTAGE (VOC) 60 C-ELECTRICAL CONTRACTOR C1524 MINIMUM START VOLTAGE (V) 30 MAXIMUM START VOLTAGE(V) 58 MAXIMUM INPUT CURRENT (ISC) (A) 15 MAX CONTINUOUS OUTPUT POWER (VA) 290 JUNCTION BOX TO COMBINER BOX (3) MAX. CONTINUOUS OUTPUT CURRENT (A) 1.21 MAX INVERTER OUTPUT CIRCUIT CURRENT = 12.1 A AC O NOMINAL (L-L) OUTPUT VOLTAGE 240 MAX CURRENT X125% = 15 A AC cu CEC WEIGHTED EFFICIENCY (%) 97.0% PER NEC 690.8(B)(I)(W/OUT CORRECTION FACTORS) z o CONDUCTOR SIZE / INSULATION / TYPE = 10 AWG THHN / THWN, CU. Q = SYSTEM ELECTRICAL SPECIFICATIONS CIR I CONDUCTOR AMP. RATING @60°C = 35 A Z o I NUMBER OF MODULES PER CIRCUIT 10 # OF CONDUCTORS IN RACEWAY CORRECTION = NOT APPLIED Q . v I N i i Q DC POWER RATING PER CIRCUIT (STC)(W DC) 3800 AMB. TEMP. AMP. CORRECTION = NOT APPLIED cc ^ � o v TOTAL MODULE QUANTITY 10 PV MODULES ADJUSTED AMPACITY COMPLIANCE (A) = 35 > 15.0 OK 2 ° °' ix c i a STC DC POWER RATING OF ARRAY 3800W DC RACEWAY SIZE / TYPE = 3/4 IN. EMT w ci z Q w INVERTER OUTPUT CIRCUIT CURRENT(A AC) 12.1 CROSS-SECTIONAL AREA OF CONDUCTOR(S) / CABLE(S)(IN."2) = 0.063 IN."2 < 6 0 o0 w °s 125/° INVERTER OUTPUT CIRCUIT CURRENT(A AC) 15.13 CROSS-SECTIONAL AREA OF RACEWAY(IN."2) = 0.533 IN."2 m Q N `s CIRCUIT OCPD RATING (A) 20 % ALLOWABLE RACEWAY FILL (NEC CHAPTER 9, TABLE I) = 40% > 12% OK 0 p lai p COMBINED INVERTER CONTINUOUS OUTPUT CURRENT 12.14 AC Z I", v� w PV POWER PRODUCTION SYSTEM OCPD RATING (X125%) 20A COMBINER BOX TO MAIN PV OCPD (10) F- Zp o o co to MAX. ARRAY STC-AC POWER (W) 2900W AC (STC) COMBINED INVERTER CONTINUOUS OUTPUT CURRENT = 12.1 A AC rn N co I'- .- Ki - MAX. ARRAY CEC-AC POWER (W) 3389W AC (CEC) MAX CURRENT X125% = 15.0 A AC DRAWING BY PER NEC 690.8(B)(I)(W/OUT CORRECTION FACTORS) ENPHASE ENERGY AC VOLTAGE RISE CALCULATIONS DIST (FT) COND. VRISE(V) VEND(V) %VRISE CONDUCTOR SIZE / INSULATION / TYPE = 10 AWG THHN / THWN, CU. VRISE SEC. I (MICRO TO JBOX) * 28.8 12 Cu. 1.4 241.4 0.58% CONDUCTOR AMP. RATING @75°C = 35 A DATE VRISE SEC. 2 (JBOX TO COMBINER BOX) 46 10 Cu. 1.3 241.3 0.56% # OF CONDUCTORS IN RACEWAY CORRECTION = NOT APPLIED 20-SEP-2022 VRISE SEC. 3 (COMBINER BOX TO P01) 10 10 Cu. 0.3 240.3 0.12% AMB. TEMP. AMP. CORRECTION = NOT APPLIED PROJECT ID TOTAL VRISE 3.0 243.0 1.26% OK ADJUSTED AMPACITY COMPLIANCE (A) = 35.0 > 15.0 OK 007RZC * 8 MICROINVERTER MAX SUB-BRANCH CIRCUIT SIZE TO COMPLY WITH VRISE CALCULATIONS. RACEWAY SIZE / TYPE = 3/4 IN. EMT CROSS-SECTIONAL AREA OF CONDUCTOR(S) / CABLE(S)(IN."2) = 0.084 IN."2 SHEET NAME CROSS-SECTIONAL AREA OF RACEWAY(IN."2) = 0.533 IN."2 ELECTRICAL CALCS. % ALLOWABLE RACEWAY FILL (NEC CHAPTER 9, TABLE I) = 40% > 16% SHEET NUMBER REVISON E-7 0 ELECTRICAL FIELD-APPLIED HAZARD MARKINGS PHOTOVOLTAIC SYSTEM AAT EACH PV SYSTEM DISCONNECTING MEANS. SIGN LOCATED ON OR NO MORE THAN 3 [NEC 690.54, NEC 690.13(B)] RAPID SHUTDOWN F FT FROM THE RAPID SHUT DOWN A AC DISCONNECT a SWITCH FOR DISCONNECT SWITCH [NEC 690.56(C)]. ION - RATED AC OUTPUT CURRENT 12.1 A SOLAR PV SYSTEM NOMINAL OPERATNGACVOLTAGE 240 V FOR BUILDINGS WITH PV SYSTEMS. TO CONFIDENTIAL-THE INFORMATION SOLAR PV SYSTEM EQUIPPED G BE LOCATED AT EACH SERVICE HEREIN CONTAINED SHALL NOT BE USED FOR PV DISCONNECTING MEANS WHERE ALL WITH RAPID SHUTDOWN EQUIPMENT LOCATION TO WHICH THE PV FOR THE BENEFIT OF ANYONE EXCEPT ION Y ARN I N B DEVELOPER,LLC NOR SHALL IT BE TERMINALS OF THE DISCONNECTING MEANS TURN SYSTEM IS CONNECTED. [NEC DISCLOSED IN WHOLE OR IN PART TO MAY BE ENERGIZED IN THE OPEN POSITION. SWITCH TO THE OTHERS OUTSIDE RECIPIENTS ELECTRIC SHOCK HAZARD or POSITION TO soJAB c 690.56(C)] [NEC 690.13(B), NEC 705.22] SHUTDOWNPVSYSTEM '+'uss ORGANIZATION, EXCEPT IN CONNECTION TERMINALS ON THE LINE AND AND REDUCE 1 WITH THE SALE AND USE OF THE LOAD SIDES MAY BE ENERGIZED SHOCK HAZARD RESPECTIVE EQUIPMENT,WITHOUT THE IN THE OPEN POSITION --..N THE ARRAY — WRITTEN PERMISSION OF ION DEVELOPER, LLC. AT EQUIPMENT CONTAINING OVERCURRENT J PERMANENT DIRECTORY TO BE LOCATED AT WARNING hP C DEVICES IN CIRCUTS SUPPLYING POWER TO A WARNING MAIN SERVICE EQUIPMENT DENOTING THE 44,-13C- D BUSBAR OR CONDUCTOR SUPPLIED FROM POWER TOTHI$BUILDINOISA�SOSUPPLIED LOCATION OF THE PV RAPID SHUTDOWN SYSTEM DUAL POWER SUPPLY MULTIPLE SOURCES. [NEC 705.12(C)] FROMAIMouNTmsoLARARRAY. DISCONNECTING MEANS IF SOLAR ARRAY RAPID CERTIFIED SHUT DOWN DISCONNECT SWITCH IS NOT SOURCES:UTILITY GRID AND SCLAR ARRAY RAPID SHUTDONMINScONNECT GROUPED AND WITHIN LINE OF SITE OF MAIN PV INSTALLATION V SOLAR ELECTRIC SYSTEM IS LOCATED SERVICE DISCONNECTING MEANS. [NEC 705.10, PROFESSIONAL NEC 690.56(C)(I)] . , �/ /� SCOTT A. GURNEY #PV-0117719-015866 PLACED ADJACENT TO PV SYSTEM PLUG-IN PERMANENT DIRECTORY TO BE LOCATED AT ION DEVELOPER,LLC D TYPE BREAKER TO A BUSBAR FOR A LOAD ®WARNING I SOLAR ARRAY RAPID SHUTDOWN SWITCH 4801 N UNIVERSITY AVE#900 PROVO,UT DENOTING THE LOCATION OF THE SERVICE 84604 SIDE CONNECTION. [NEC 705.12(B)(3)(2)] POWER TO THIS BUILDING IS ALSO EQUIPMENT LOCATION IF SOLAR ARRAY RAPID POWER SOURCE 888.781.7074 OUTPUT CONNECTION - SUPPLIED FROM MAIN DISTRIBUTION SHUT DOWN DISCONNECT SWITCH IS NOT DO NOT RELOCATE THIS UTILITY DISCONNECT LOCATED GROUPED AND WITHIN LINE OF SITE OF MAIN DAVID STANLEY CONRAD OVERCURRENT DEVICE SERVICE DISCONNECTING MEANS. [NEC 705.10] C-ELECTRICAL CONTRACTOR CI524 n o A C ►GI a ElN UTILITY(E) © D W F❑ Q U W METER (E) MAIN SERVICE PANEL COMBINER BOX _ I CDN i TaV k.. &YIMV ao N U MIMING _&YAWNIN _ .. 0 CS, N J I-- Q ' - Z a_ N U o. ... 0 0 Z Q C° W 0 &WARNING. M:'•.ice 1 cn in W Os (/) W • tY = OK CO C3 N L PV SYSTEM ao DISCONNECT(S)TO OW CI 0 O Li_ a_ p PV INVERTER Z Q Cl) Icp J Z (N) PV BREAKER OUTPUT CIRCUIT(S) W Q W 1— Z O, 0 cO 0 o O CD CDc.000 N ® o o (n N a0 H ... .. ND E" DRAWING BY ,ate ENPHASE ENERGY 1111.1. DATE LriN1 21 20-SEP-2022 PROJECT ID 007RZC ALL CAUTION, WARNING, OR DANGER SIGNS OR LABELS SHALL: SHEET NAME I, COMPLY WITH ANSI Z535.4-201I STANDARDS. ELECTRICAL LABELS 2. BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN. 3. SHALL BE OF SUFFICEINT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 4. UNLESS OTHERS SPECIFIED MINIMUM TEXT HEIGHT TO BE g" (3MM). SHEET NUMBER BENISON E-9 0 AST 2o2.= !O t IDENTIFICATION OF POWER SOURCES A PERMANENT PLAQUE OR DIRECTORY TO BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION ION DENOTING THE LOCATION OF EACH POWER SOURCE DISCONNECTING MEANS AND SHALL INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. FOR THE BUILDING OR STRUCTURE AND BE GROUPED WITH OTHER PLAQUES OR DIRECTORIES FOR OTHER ON-SITE SOURCES. ALL MARKING TO COMPLY WITH 110.21 (B). (NEC 705.10) CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT ION DEVELOPER,LLC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE `/ RESPECTIVE EQUIPMENT, WITHOUT THE CAJTIO \ : V U LTIDLI-- WRITTEN PERMISSION OF ION DEVELOPER, LLC. SOHCES OF D 0 W R ,, NABCEP POWER TO THIS BUILDING IS SUPPLIED FROM THE CERTIFIED PV INSTALLATION FOLLOWING SOURCES WITH DISCONNECTS LOCATED PROFESSIONAL AS SHOWN : .+�/' SCOTT A. GURNEY f #PV-0117719-0I5866 P V ARRAY ION DEVELOPER, LLC LjJ 4801 N UNIVERSITY AVE#900 PROVO, UT z 84604 Q I 888.781.7074 J 0 B O B DAVID STANLEY CONRAD Q C-ELECTRICAL CONTRACTOR = W C1524 CC D 0 oer El m 0 El B El CI H 2 I-1 ❑ ❑ H- z 0 D O 0 z c� O Q c) w Li_ J = NIVV cv f— O O Q cV U O` 4 re) ND (E) (N) N ^ ai co M� C S - D I- U 2 0 0, J Q -UTILITY SERVICE DISCONNECT O W w Z a cs w F— W O 0 — a U RAPID SHUTDOWN AC z D = w as DISCONNECT SWITCH 0 D 0 a = .. UTILITY SERVICE METER w < o a z z ~ O r(D O O - (/) 0 co F- Z. r!) DRAWING BY ENPHASE ENERGY DATE 20-SEP-2022 PROJECT ID 007RZC SHEET NAME ELEC. DIRECTORY SHEET NUMBER REVISON E-I0 0