Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
JESSE HAWKINS RECEIVED NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM SEP 1 2 2022 DC SYSTEM SIZE (5. 55KW) CITYOFTIGARD R uILPINGh VISION SITE MAP (N T S) SYSTEM DETAILS o / u , it ` DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC ,I \ } SYSTEM WITH NO BATTERY STORAGE t VALIDITY OF PERMIT I DC RATING OF SYSTEM SYSTEM SIZE:5.55 KW DC STC ; �- ADD:19450 SW MOHAVE CT., THE ISSUANCE OF A PERMIT TUALATIN,OREGON 97062,USA. BASED ON CONSTRUCTION CONTACT:saa�ss-1 saw AC RATING OF SYSTEM 5 KW DOCUMENTS AND OTHER _ ,< anv- AC OUTPUT CURRENT 21 A DATA SHALL NOT PREVENT as �n �''-" "�� � �, ``'�` � � I (15)SILFAB PRIME SIL-370 HC(370W) THE CODE OFFICIAL FROM ar :NO.OF MODULES MODULES REQUIRING THE CORRECTION (NVERT KEDGE SE 5000H-US HD WAVE OF ERRORS. ORSC 105.4 Q w NO.OF INVERTERS CD fLn NO.OF OPTIMIZERS 15 P401 SOLAREDGE POWEROPTIMIZER a� ` dl � '.. ( ) OPT M ZER :,;a„• ,"�'�. , SW F 31thi1NPD 9t .. SW Faerha' t* „ Q POINT OF CONNECTION BACKFEED BREAKER IN THE MSP iso-9• ate , ARRAY STRINGING c (1)BRANCH OF 15 MODULES 4. >I fV I I VICINITY MAP OFFICE COPY v) zz o I Ln SITE DETAILS (E)MAIN SERVICE PANEL cfi. ASHRAE EXTREME LOW -8°C n•_e• (INSIDE HOUSE) `� O ASHRAE 2%HIGH 33°C 51111illiggiiii - > 't „tc Cc (E)UTILITY METER N— I GROUND SNOW LOAD 20 PSF 12"SETBACK (OUTSIDE HOUSE)(N)AC DISCONNECT AND 10 65 SW Fairhaven St.Ti ard,cn 8 RAPID SHUT DOWN DEVICEWIND SPEED 96MPH(ASCE 7-16) CSR 97223,Unoted States II CN.M.M.661 � 1 I (N)SOLAREDGE SE 5000H-US RISK CATEGORY �IHD WAVE INVERTER LWIND EXPOSURE CATEGORY B � o 03' .•9 GOVERNING CODES TSRE:"% '41tt TSRE:78M° Z Z p O DRIVEWAY 1 15)SILFAB 370 HC MODULES 5 5 2 INTERNATIONAL RESIDENTIAL CODE IRC 2018 ARRAY 1 F� *a �3 r k a ( ) TILT:15) OLBA°R EDGE P-401 POWER OPTIMIZERS war i r . U' w INTERNATIONAL BUILDING CODE(IBC)2018 AZIMUTHS 180° •" o INTERNATIONAL FIRE PREVENTION CODE(IFPC)2018 1 i3o-v J ) NATIONAL ELECTRIC CODE,NEC 2020 CODE BOOK,NFPA 70 SW FAIRHAVEN ST WIND FLOW MAP 0 O SHEET INDEX CITY OF TIGARD LIABILITYLi REVIEWED FO OD : COMPLIANCE rhe City of Tigard and its SHEET NO. SHEET NAME PERMIT DEVELOPER A-00 SITE MAP 8 VICINITY MAP Approved: [ ] employees shall not be {ETC: [ l responsible for discrepancies t?I0 DATE 09/09/2022 S-01 ARRAY LAYOUT which may appear herein. 3Y Vancouver S-02 STRUCTURAL ATTACHMENT DETAIL 24�(and „�,, DESIGNER ORM Permit#: L � q�J E-01 ELECTRICAL LINE DIAGRAM �l ��� `� �� , <,L..r t} ., - E-02 WIRING CALCULATIONS Address: 14�50 r- ,✓L✓) 5'� Fp�w r;,� {{r Ana"� REVIEWER DS-01 MODULE DATASHEET Suite #: p SHEET NAME J / 1 DS-02 OPTIMIZER DATASHEET B`: yY� Date: I��({ ZZ " SITE MAP & DS-03 INVERTER DATASHEET to,. VICINITY MAP DS-04 ATTACHMENT DATASHEET DS-05 RACKING DATASHEET Salem SHEET NUMBER A-00 1445T2o22 32. ROOF DESCRIPTION: (ROOF #1) MODULES-15 ROOF TILT-18° ROOF AZIMUTH-180° TRUSSES SIZE-2"X4"@ 24"O.C. Signature with Seal SPEEN IDGE ADD:19450 SW MOHAVE CT., TUALATIN,OREGON 97062,USA. CONTACT:503-395-1943 0 ',.. nn rr Vt 1-4 12" SETBACK z v) 11.1 r " Q f— 54 -2 —� z � w Ir rn { r v7 CO CD o j I f I I I I i - o c I\ 29' 4" + - - . '-I w (NJl o / ' CO I\ 1 U 27'-l" re SI I ROOF#1 J LEGENDS W SOLAR MODULE > FIRE SETBACK w c -VENT,ATTIC FAN PERMIT DEVELOPER (ROOF OBSTRUCTION) -PV ROOF ATTACHMENT DATE 09/09/2022 -COUPLING DESIGNER ORM I -RAFTERS/TRUSSES REVIEWER -RAILS SHEET NAME -WIND ZONE I ARRAY LAYOUT -WIND ZONE II SHEET NUMBER -WIND ZONE III S-01 p45T 2D22--(632s CONDUIT SCHEDULE NOTE: ARRAY DETAILS 1.SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE SR.NO. DESCRIPTION CONDUIT SIZE REQUIREMENTS OF THE NEC 2020,NFPA 70 INCLUDING MAXIMUM DC SYSTEM SIZE sss Kw NUMBER OF MODULE STRINGS,MAXIMUM NUMBER OF MODULES PER 0 PV WIRE(FREE AIR),(1)#10 AWG THWN-2(G) FREE AIR AC SYSTEM SIZE 5 KW STRING,MAXIMUM OUTPUT,MODULE MANUFACTURER AND MODEL - NUMBER,INVERTER MANUFACTURER AND MODEL NUMBER,AS O (1)#10 AWG THWN-2(+),(1)410 AWG THWN-2(-),(1)#10 AWG THWN-2(G) I IN 3/4" CONDUIT RUN TOTAL NO.OF MODULES 15 APPLICABLE. NO.OF MODULE PER STRING 1 @15 2.PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTER Signature with Seal O (3)#10 AWG THWN-2(L1,L2,N),(1)#10AWG THWN-2(G) IN 3/4"CONDUIT RUN SPACE IS INADEQUATE. NO.OF STRING 1 O (3)#10 AWG THWN-2(L1,L2,N),(1)#10AWG THWN-2(G) IN 3/4"CONDUIT RUN , SPEEN IE E.0 ADD:19450 SW MOHAVE CT., TUALATIN,OREGON 97062,USA. CONTACT:503-395-1943 0 CC (15)SILFAB PRIME SIL-370 HC(370W)SOLAR MODULES WITH Q (15)P401 SOLAREDGE POWER OPTIMIZER (I') Z H r 1 8E5000 H-US Y Q I I SOLAREDGE SINGLE PHASE HD WAVE INVERTER Z I 5000W,99%CEC 240 VAC,21AD WITH BUILT IN DC DISCONNECT EQUIPPED WITH LLJ isRwi� RAPID SHUTDOWN Q Q N rSirat Lasip: INTERCONNECTION = raRr^ 120%RULE-NEC 705.12(D)(2)(3)(b) TO UTILITY GRID UJ ct 0 PIP r. Z UTILITY FEED+SOLAR BACKFEED ^ a L2 100A+30A=130A (OUTSIDE HOUSE) Cr) PEI"i BI-DIRECTIONAL 5 Illaltall r.aai. \/ BUSS RATING x 120% (a UTIUTYMETER U) L c i l� 125A x 120%=150A 1-PHASE,240VLO L1 L2 (N)AC DISCONNECT (INSIDE HOUSE) MA 3R ULLISTEDD L1 L2 (E)MAIN SERVICE PANEL ® ® E ig] 4 126A RATED,240V J1Jr 2! , 1 j 100A FIDIPIP 11 L, _. — r"�Ivl` ✓��1 `i (E)MAIN BREAKER Z z -. Er- _- 100N2P,240V 0 0 L7 L1 U rt W o ALSO SERVES AS RAPID u u A O SHUTDOWN DEVICE.TO BE 3 (1)STRING OF 15 MODULES LOCATED WITHIN 10'OF 30Ao UTILITY METER j L L' W C re n .G orjor X.) PERMIT DEVELOPER L �- ——-Ci''' GEC#4 TO GROUND ROD OR (N)JUNCTION BOX — EXISTING STRUCTURE UFER DATE 09/09/2022 600 V,NEMA 3R UL LISTED DESIGNER ORM OPTIONAL FIELD DETERMINED REVIEWER SHEET NAME ELECTRICAL LINE DIAGRAM SHEET NUMBER E-01 1 ELECTRICAL NOTES ELECTRICAL CALCULATIONS: 1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. 1. PV OVER CURRENT PROTECTION ...NEC 690.9(B) 2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR = TOTAL INVERTER 0/P CURRENT x 1.25 75 DEGREE C. 3.CONDUCTOR TERMINATION AND SPLICING AS PER NEC 110.14 Signature with Seal 4.WIRING, CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS = (21)x 1.25 =26.25A SELECTED OCPD =30A SHALL BE ROUTED DIRECTLY TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. GPEEN RIDGE 2. BEFORE INVERTER: 5.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. AMBIENT TEMPERATURE=33 6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. ADD•19450 SW MOHAVE CT., CONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF NEC 310.15(B)( )( )3 c CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, TUALATIN,OREGON 97062,USA CONTACT:503-395-1943 TEMPERATURE DERATE FACTOR-(0.96) NEC 310.15(B)(2)(a) SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE GROUPING FACTOR-(1) NEC 310.15(B)(3)(a) CODES AND STANDARDS. 7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS CONDUCTOR AMPACITY ARE NOT SPECIFIED,THE CONTRACTOR SHALL SIZE THEM IC = (OPTIMIZER 0/P CURRENT)x 1.56/A.T.F/G.F ...NEC 690.8(B) ACCORDINGLY. Q = [15 x 1.56]/0.96/1 8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED 0= 24.38 A SELECTED CONDUCTOR-#10 THWN-2 ...NEC 310.15(B)(16) AND READILY VISIBLE. Ul 0 9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE 2 3. AFTER INVERTER: FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP Y MANUFACTURER'S INSTRUCTION. z TEMPERATURE DERATE FACTOR-0.96 10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER Q w 05 GROUPING FACTOR-1 G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. N i Q N 11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE . I rn CONDUCTOR AMPACITY 12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL LU 1Y O = (TOTAL INV 0/P CURRENT)x 1.25/0.96/1 ...NEC 690.8(B) PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE NCE. [(21 x 1.25]/0.96/ 1] 13. MODU ENTES CONFORM TO AND ARE LISTED UNDER UL 1703. rW-� U) 27.34 A 14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. Lc) SELECTED CONDUCTOR-#10 THWN-2 ...NEC 310.15(B)(16) 15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS rn =#10 THWN-2...NEC 250.122 SUNLIGHT RESISTANT PER NEC ARTICLE 300.E(C)(1)AND ARTICLE SELECTED EQUIPMENT GROUNDING CONDUCTORA (EGC) ( ) 310.10(D). DC SYSTEM VOLTAGE 16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10(C). I W MAX OPEN CIRCUIT VOLTAGE(-DC TO DC+) INVERTER SPECIFICATION o =NO. OF MODULES/STRING x Voc =15 x 41.75 MANUFACTURER SOLAREDGE INVERTER u) =626.25 V MODEL NO. SE5000H-US 0 O MAX.OUTPUT POWER 5000 W W E N rx MAX.AC OUTPUT VOLTAGE 240V o MAX VOLTAGE DROP CALCULATION AC OUTPUT CURRENT 21 A 0 O ONE WAY BRANCH RESISTANCE OF %VOLTAGE DROP= OPTIMIZER SPECIFICATION w CABLE SIZE CABLE DESCRIPTION DISTANCE IN CURRENT(I) CONDUCTOR(R) VOLTAGE (V) (0.2*D*I*R) ',. FEET(D) /V MANUFACTURER SOLAREDGE OPTIMIZER #10 THWN-2 PV ARRAY TO 20 15 1.24 626.25 0.118 MODEL NO. P401 INVERTER OPEN CIRCUIT VOLTAGE(Vac) 60V PERMIT DEVELOPER SHORT CIRCUIT CURRENT(Isc) 11.75A DATE 09/09/2022 #10 THWN-2 INVERTER TO 10 21 1.24 240 0.22 MAX.AC OUTPUT CURRENT 15 A DESIGNER ORM MSP MODULESPECIFICATION REVIEWER MANUFACTURER SILFAB SHEET NAME MODEL NO. PRIME SIL-370 HC WIRING OPEN CIRCUIT VOLTAGE(Voc) 41.75 CALCULATIONS SHORT CIRCUIT CURRENT(Isc) 11.25 RATED VOLTAGE(Vmpp) 3495 SHEET NUM^/BER RATED CURRENT(lmpp) 10.60 `_O` • ELECTRICAL SPECIFICATIONS '-:'..**ILW-1-**'•441:1-AterEt,'°,4'4 P,W;410"1,*:040.1, r,st Coon fions STC HOOT Module Power Iffmax) Wp 370 276 Signature with Seal 41-a Maximum power voltage(Vpmax) V 34.95 3248 111• ••*•• Maximum power current(Ipmax) A 10.60 8.50 it•• Open circuit voltage(Voc) V 41.75 39.16 ....... SILFAB PRIME S I L FP B • Short cretin current:Ise) A 1125 9 07 ' ' EN P10GE Ailt Module efficiency % 20.2% 18.9% SOLAR- Maximum system voltage(VOC) V 1000 SIL.370 MC Series fuse rating A 20 Power Tolerance Wp 0 to*10 ADD:19450 SW MOHAVE CT., TUALATIN,OREGON 97062,USA. Measurement conditions:STC 1000 W/inf•AM 1.5.Temperature 25 fC•HOC 800 Wirnf•AM 1.5•Measurement uncertainty 3% CONTACT:503-395-1943 Sun simulator calibration reference modules from Fraunhofer Institute Electrical characteristics may vary by 35%and power by°to+IOW. MECHANICAL PROPERTIES i COMPONENTS f' METRIC • 71161,iftfr&f,t, IMPERIAL Module weight 10.54 30.2kg 431bs±0.41bs Dimensions(H x L x DI 1762 men x 1037 mm x.35 rem 69.4 in x40-8 in x 1.37 in ... Maximum surface load iwrod.isnow)) 5400Pa Tear load;5400Pa front load 112.8 Iblft rear load/112.8 lbfie front toad 0 Hail impact resistance m 25 mm at 83 kmih o 1 in at 51.6 mph Ct 120 Half:ells-Si mono PERC 120 Half cells.Si mono PERC < Cells 9 busbar-83 x 166 rnrn 9 busbar-3 26 x 6.53 in 0 3.2 mm high transmittance,tempered, 0128 in high transmittance,tempered, (1.) Glass I- OSM antireflective coating DSM antireflective coating Cables and connectors(refer to installation manual) 13.50 mrr,o 5.7 mm,MC4 from Staub"; 53.15 in,0 0.22 in(12AWG),MC4 from Staubli I.-i ij 8acksheet ,cor --... Highm dubility,superior hydrolysis and UV resistance,multi-layer dielectrk film, a,l..A ers v.. fluorine-free F•V backsheet Frame Anodizec Aluminum(Black) Z D LU - Bypass diodes 3 diodes-305Q045T/45V nEax DC blocking voltage,30A mar forward rectified current' C:C > Cf) Junction Box Ul 3730 Certified,IEC 62790 CerIfied,IRAS rated TEMPERATURE RATINGS WARRANTIES I Temperature Coefficiem Isc +0 063 TirC Mixtule product workmanship warranty 25 years" LI.J ct cr) - Temperature Coefficient Voc -0.28%,DC Linear power performanceguara.ntee 30 years < CfC Temperature Coefficient Pmax -0.36 flfirC .057.1%end 1st yr V) I-L ,91 6%enci 12th yr NOG 61 2°C) 45°C 11.1 ,,5 1%end 25th yr Operating temperature -40,85"C .f,82 efi.end 30th yf rn (i) CERTIFICATIONS SNIPPING SPECS 4 (0 ITC ORD C1703,UE1703,CEO Tsted,IL 61215-1).1 132.3E 61730 1-2, Modules Per Pallet 21)or 261California) 0-) Product Ifit 61215.111.1/2.".IEC 61730.1,2"",CSA C22.2n1730.1f-2.IEC 62716 CS Ammonia Corrosion;IEC61701,2011 Salt Mist Corrosion Certifed,UL Fire Rating Type 2 Pallet.Per Truck 34 or 32(Caiifornia)Factory IS09001:2015 Modules Per Truck 884 or 832(California) . •Warning,Read the Safety and installation Manual for mounting specifications and before handfing installing and operating modeles. .' 12 year extendable to 25 years subject to registration and conditions outlined under'Warranty"at,fitobanfet.one, *" Certification in progress. PAN flies generated from 3rd parry performance data am available for download at.3316%mfesessm.idessetvort, 1.I.1 . t < CI 69A"11762mrrS i SILFAB SOLAR INC. .. • .. - E W E 800 Cornwali Ave Z z -a Bellingham WA 98225 USA 0 il;:' 14'1356MM1 41.3"11050MM1 14"1356MM] oi IT --;- .-- - T+1 360.569.4733 'irr.Y,-; 5 CC info@silfabsolaLcom Ill 0 8,1fie88.0LAA.COO Et gj e - RELIABLE ENERGY. ii, .s,.v.- Mounting Hole(x4) 1770 Port Drive Burlington WA 98233 USA DIRECT FROM THE SOURCE . d.,....,.;; 0.5" [12mm] T-0.350.569.4733 ,`',,,'... .... ... (.9 z 0.-,..•,:-. 240 CAuitheypark Drive East Introducing Sitfab Prime. 1 I Mississauga ON 1ST 2Y3 Canada ii,-IK, I 3 - T+1905.255.2501 > Designed to outperform. it.,4 j 4"13.5mmL -E- ').E "ff. E "L" ,.. E F,1 905.696.0262 , ul CC co Zo, E c,I co Dependable,durable,high-performance solar panels W.:1i 1'14 1_, . ..., 0. _ __ EL c) .„... SAMS-SIL3TANC-2021.0803 in '""' fiereproaficarmar my iffnduanowefivenfaut . s 0) co permission M.anfi knformat..ontssubfeci to PERMIT DEVELOPER engineered for North American homeowners. WO ...-4 Iii' 3 0.06" 53.15' •••?-"` 0 m c$ modifecations without nofice.*SO.&Sae,Inc. Ti3 .*. 2021SItfab Solse"ma trade-in.&Serb Saw., N. e SILFABSOLAR.CO DATE 09/09/2022 X*P.1 •k414., r- 11.5mrni 11350mm] ...- _ - - 6 2 -= Cable Length i,. e DESIGNER ORM r 0 t*,! Avit Drainage Hole(LS) E -/.,. REVIEWER / C I I 0 (09 0 1 EC 7. , 774 Fraunhofer c..!..:ee 2 4'I6Omin] / 8"[200mm] Na...,:A .... -.. • ..... ... SHEET NAME MODULE DATASHEET SHEET NUMBER DS-01 IV1ST 2©22 -oo 325 Power Optimizer For North America SiPovver Optimizer 0 P320 / P340 / P370 J P400 J P401 / P405 / P485 / P505 natere sal OP370 I i For North America Optimiermodel P320 {forhgh- (for higher- : P400 (fargh I P405 P485 P505 power (for 72& (for high- (for high (for higher E l (typical module (for 60-cell power 60 and 72 46 cell power 60 voltage voltage current , "a DGE 0 P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 compatibility) modules) 60-cell • cell modules) and 72 cell modules)g g modtile0 modules) modules) modules) modules) ADD:19450 SW MOHAVE CT., INPUT TUALATIN,OREGON 97062,USA. Rated Input DC Power' � 320 340 1 370 i 403 -I 405 1 485 1 505 W CONTACT:503-395-1943 27:1Absolute Maximum Input Voltage 1 80 i 60 t, 125' 83 Vdc 5 Noc at lowest temperature) 48 MPPT Operating Range - 8-48 8-60 8 80 ' 8-60 1 12.5-105 125-83 1 Vdc YEAR Maximum Short Circuit Current __._ I I _ LL WARRANTY 0 Ma — 1 — /0.1 r.7s 11 ---- 14 Adc Maximum Efficiency ! 99.5 % _Weighted Efficiency 98.8 _ 1 98.6 i % Ur_ .. „..._ Overvoltage Category--- 1 _._ - --_ --.__._ II -----_ -. -- ---- I OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) - Z Maximum Output Current .____ u 15 - -- --- I Adc__ 0-4Q — t 3 _ Maximum Output Voltage --_--------- 60 -- -r 85 -- , Vdc Z D OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)_ W E Sa#ety O tput Voltage per Power 1±0.1 Vdc - 1 Q N _- rn / CC%t m,7C" J -.. .... _ —_ _ _ _ _. __ ___ STANDARp COMPLIANCE mom EMC FCC Part15 Class 8,.EC6100026-2,IEC61000 6-3 N Safety --- EC62109-1(Gass 4 safety),UL1741 - Material UL94 V-0,UV Resistant - W 0 RottS Yes I r,.,� U) INSTALLATION SPECIFICATIONS LO CO 1,..a.mun,A'laweo SystE n 1000 ' Vdc O Voltage - -_._ - -______-�w__ O Compatible inverters _ _ -_ - - All SolarEdge Single Phase and Three Phase loveriers - __ Dimensiors(W x I_x H) 129x153x27-5/5.1x6x11 f129x153x 33.5:129x153x29.5, 129 x159x 49.5/5.1x 6.3x1-9 j129x162x591 rnm 1 /5.1x6x1.3 /5.11(6)016 I 5.1x64x.23 /In Weight(including cables; i 630/1.4 750/1.7 655/15 845/1.9 1 1064t2.3 i grItb 1 -.-_ -_ i Single or dual }, input Connector ! MO40r MC4- hdC4,, I w Input Wire Length --- ------ 016/0.52-----_-_-_-- m/ft a Output Wire Type/Connector Double Insulated/MC4 Output Wire Length 0.9I 2.95 i 1.213 9 1 m S ft co Operating Temperature Range _ -40 +85/40 +185 _ _ __-, + C I T Z o PV power optimization at the module-level Protection Rating -- - - - — - _ 1P68;NEMA6P----_ _----_- ----. --._ -- 5 a Relative Humidity 0-100 % w v K w 0 1 Specifically designed to work with SolarEdge I Fast installation with a single bolt (`I Rated power of the moa.eat$Cw;(notesweedthe°psi =er'Rated;n;.DC Pewee ryas ieswah„ptoe5%powertauerarrceareailo„ed (2)NEC 20'7 requ.res max input voltage be-rot more than 80V inverters (3)For ohe'cmnector rype<_please cootact SolarEdge 6 (47 rot d a verslon for pas Ie ,�u n, necta of two rod!es;,,e P485-4NMDMuM in the case of an odd rnmiw<of PV rnodLien::.one arieq,iMaa+sm one P485 ch,a veritor pave opt;mlzer c:mn rested Z nePemodule When cnnectmgasnp;< Desea'theumwedenp„icoe;torswa„me supplied pa;,ofseals. w / Up to 25%more energy level monitoring e>1 FOr amtxem temtteranrre aouve_85 C/+185,cower de-rating b apPaed.Refer to Power optom:zets Tempe; De-Rat.g TecW,icai Note is more degas. w I Superior efficiency(99.5%) 1 Meets NEC requirements for arc fault PV System Design Using Single Phase Three Phase for Three Phase for phase p protection(AFCI)and Photovoltaic Rapid a SolarEdge Inverter HD-Wave Sing 208V grid 277/480V grid PERMIT DEVELOPER I Mitigates all types of module mismatch losses, Shutdown System(PVRSS) Minimum string Length P320,P340,P370, 1 8 to 18 P400 P401 ..I_..__.__ from manufacturing tolerance to partial (Power Optimizers) — -—___ - P405 P485,P505 1 6 8 14 t - DATE 09/09/2022 shading I Module-level voltage shutdown for installer Maximum string Length(Poweroo'imizersl 25 z, say and firefighter safety , 5700(600 with DESIGNER ORM / Flexible system design for maximum space Maximum Power per stria i 5E7600 5 sr O400-u 5250 6000' u750x W ) utilization Parallel Strings o'Different Lenoths or Orientations Yes - REVIEWER (6)•a de a7ed Crag song,nfor a or re er to l ru a w sofa edge.e.orrilsr1esroe a N.15teshmng_suing rw-pd` s"/;t a not towed tx,'xi,P41Pa P4P5t 5J.tt 03 p/i T,t,P400/P4p1 w,one 5.rig SHEET NAME 'P„A st eq tr,mote man 30 opt m zr doe,rn as n sh toe n est,reme,s.saretc r,tage t be above the.30V reo rement t� /, O t, wear, s:a p s >x lc c,we emawm rrpo e dter t ,.eneahstf gi ,NOW OPTIMIZER (10 to t 45/V g o vvc,to as tp ri ,,,1w per strwc,wher the M powe dw ,< -betwefw each.or rig ss 7_t,DW solaredge.com solar - I e 44. 11). DATASHEET e SolarEdge T Imoiogan Ltd AN rghis reserved.SOLARE'DGE.the SolarEdge logo,OPTIMIZED BY sO,AREDGE trademarks registered trademarks of SolarEdge Tethnotogo Inc GC /V Ro H S AN other trademarks mentioned hemp am trademarks of their respective owners.Date 07/102o/VoaffNG NAM.Subject to change without eotce Intertek SHEET NUMBER DS-02 Signature with Seal * EN RIDGE C) '.CLAD .. ADD:19450 SW MOHAVE CT., ! TUALATIN,OREGON 97062,USA. CONTACT:503-395-1943 Single Phase Inverter with HD-Wave Technology !Single Phase Inverter with HD-Wave Technology Single Phase inverter for North America for North America / SE3000H US/SE3800H US/SES000H US/SE6000H-US/ SE3000H-US/SE3800H-US/SE5000H-US/SE6000H-US/ With HD-Wave Technology \ SE7600H-US/SE10000H-US/SE11400H-US SE7600H-US/SE10000H-US/SE11400H-US mMODEL NUMBER 5E3000H US SE3800H US SES000H US SE6000H US SE7600H-US SE10000H US 5E11400H-US MODEL NUMBER SE3000H-US SE3800H-US SES000H-US SE6000H-US 5E7600H-US Si yn:1H-US'SE114OSH-US CI • ADD TlQ JAL FE T)frES V for North America APPLICABLE TO INVERTERS SEXXXXH-XXX%XBXX4 V WITH PART NUMBER SE3000H US J SE3800H US j SE5000H US j SE6000H USJ OUTPUT _ tarsi=�m�` NrK 3 ~ Q SE7600H—US/SE10000H—US/SE11404H—US t t»m> onnfi "' ,teSe9% O140,,..PongBak-010-HWesEntUc2 CoenOm ( en M ., J.o ,,,a,0,,10 .,SIX' MO, 'A rN NEC 202959p EL Arid,NK AAntiktRg25tn.rttlmrn uppiK Gm Jtummea 12 ec.> YEAI' _ r ' . _, __. ._ STANDARD GONP4tANCE .__...._............__.. o -. _..__....--___ ._...[ W Sate" _ u.,i�tk.tt:SA. tw396.tit,C22.Cvaau AFC,accurAn9U L Mir , - - _ — S ,- C,r f( Sxd W lEffSSF?.Ruk 21 krvMM7 _ Q N 1y eCN INSTALLATION SPECIFICATIONS w - FICA - — -- -� ____.. __ _.._� 1 TIONS :u n '.Msc. .t'-4-6 AWG Max... ,x4:-t AwG ' -- 1'M mirrv112 arcys/V-COWS "M ..3 ys SAWN ua < ,S -< - 45 n fX mW i efs' W 1^J rt+r'dcrt .__. AWG Range _ j _ _.__. LL 0 R7 0 0.- xa, As+c ._._.._ ....__. ,rymemomwtt S#m,-;; 0,0D' 19bx6 Sti 3h)xi' 21 b 3 c40 ?Mx 19. -rtm A, .00 "+", t,_ we,9k vtt,Safety Swis* i S tt4 re,?;,,,,, 36 06 i R,/15 • t4 ny mtr P , w Not= 25 _ SC th3A , 4 4es - _.._... .. _ .._ _.__...�...__ . �_____._ ..Nan, C _.._. r� INPUT - - .. air-4D _ _ i-•y,'L LO +".�"..... o,:,-. r .a". se=r �. '_"` .__.sc _ _"_< -"°o` ---_x _',5.. raa - -.. wr v'v sat- _....._ (� . nnea;,mom- O a.... .... A 4 *: — we w�w.�.:. w,ow..rt.�, tMi ___.. w� 4Ahv3 51K 1>:G ,SWC -w- 0: 'fe• VW`Ltete M SEwa,-'i0i.n maukmbrftty'-. a ♦ 4 ,a.... `t.:.. • k,,,,• nv..., __ .i ____ _ _. N sit mktwfmwm'r. qt't" nxM,%e a`*a* wex mW C) A '.'DC Mk,Wta0e 3,£2 /w-L sit M , 0245 10 + Y3 Ad, How to Enable Consumption Monitoring M an AlOBt 3 ` `"'°',,,,, -- - -- - 8y simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service 's .00 o P — _ "a panel,homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills .► w ▪ i ,Dateo,or. H mow, r A < w • , ._ __ .._.. _.. -�---- ----- -----_ ___:_t<_ +- 5ing7e phase inverter with 8 Optimized installation with HD-Wave technology • R.,,, HD wave technology and w _. ,b,ee %V ertt t ett.., :ot Ott,tt,Ut bvil5-In RUM and co Service Panel consumption monitoring Z 2 t Specifically designed to work with power optimizers J UL1741 SA certified,for CPUC Rule 21 grid compliance 0 Q 0) a / Record-breaking 99%weighted efficiency I Small,lightweight,and easy to install both GridSin K outdoors or indoors ill / Quick and easy inverter commissioning directly from 4 a it N i2 Ce 0 a smartphone using the SolarEdge SetApp I Built-in module-level monitoring r«► sh,.eldedCSTse Sabie •t Fixed voltage inverter for longer strings t Optional:Faster installations with built-in 5 •—'� '---" N 1..2,it•1t irg O consumption metering(1%accuracy)and ♦ i r. ? 5 Integrated arc fault protection and rapid shutdown production revenue grade metering(0.S%accuracy, ' .j 'V l:lwl <i x= for NEC 2014,NEC 2017 and NEC 2020 per article ANSI C12.20) Cawua 690.11 and 690.12 w EC soiaredge.com solar- ! t .„ ,a ':" , —. .r .,m.,. RoHS s :�e . PERMIT DEVELOPER DATE 09/09/2022 DESIGNER ORM REVIEWER SHEET NAME INVERTER DATASHEET SHEET NUMBER DS-03 40, IRONRIDGE FlashVue 2)Washer, EPDM Backed Signature with Seal 111-101—.14 0 35 Property Value G F1► E Q -} Material 300 Series Stainless Steel Finish Clear ADD:19450SWMOHAVECT., 0.75 TUALATIN,OREGON 97062,USA. 0 CONTACT:503-395-1943 O ,,... 3) Grip Cap `viill� 40 a.- 7i— .36 I ••— d too z ' Q 1-.-4± 2.74 w Z D ITEM NO DESCRIPTION QTY IN KIT ��,,.,,y�t Q > M 1 BOLT, LAG 5/16 X 4.25" 1 I _ Ril 2 WASHER, EPDM BACKED 1 --- - U.J il rn 3 FM FLASHING, MILL OR BLACK 1 U) . O 4 GRIP CAP, MILL OR BLACK 1 W Property Value Ln FLASHVUE cs) Material Aluminum rn 0 Finish Mill/Black PART NUMBER DESCRIPTION FV-01-M1 FLASHING, FLASHFOOT, MILL FV-01-B1 FLASHING, FLASHFOOT, BLACK 4) FM Flashing 0 W 1) BOLT, LAG 5116 x 4.25" 8.0 o s - .32 LU 0 0 61 \ 5l16 THD IX 0 111t1t11►1�1�►�1111�1�1111�1�1�t11111i1�1i1►* il z i, a W 4.25 12.0 7/16"Head Property Value PERMIT DEVELOPER Property Value 1/ C® Material 300 Series Stainless Steel Material Aluminum DATE 09I092022 Finish Clear �` Finish Mill/Black DESIGNER ORM v1,p v1 A REVIEWER SHEET NAME ATTACHMENT DATASHEET SHEET NUMBER DS-04 #15r2012- CO32v l • I rid IRON RIDGE XR Rail Family XR Rail Family Signature with Sea The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific Solar Is Not Always Sunny design loads,while minimizing material costs.Depending on your location,there is an XR Rail to match. "�# EE PI WA F A',, Over their lifetime,solar panels experience countless _ extreme weather events. Not just the worst storms in years, • - •_, 1 - T, . _ UALDATII' O EGON09 062,USA. but the worst storms in 40 years. High winds capable of ` .., ^�""" CONTACT:e03395-1943 • ripping panels from a roof,and snowfalls weighing -� ' ....6„,,„ % enough to buckle a panel frame. vi _ „ -~ -.`,.,Y --''"`"`.nw w+ru4,*** ...`„"'"rw,y.w,.r+�.r, W.•u.,,,,.,,,,,,� • 4"111 • XR Rails are the structural backbone preventing . " these results.They resist uplift,protect '`� •�� - F XR10 XR100 XR1000 against buckling and safely and efficiently `' 4, " "� T - " , Q h ., y ,{ Y { XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among (_� transfer loads into the building structure. ' - rail,designed for regions with light or mountingrail.It supports a range of solar mountingrails.It's built to handle .. w . 9 9 9 PPo 9 Their superior spanning capability '` , ' X * t no snow.It achieves spans up to 6 feet, wind and snow conditions,while also extreme climates and spans up to 12 Z ., while remaining light and economical. maximizing spans up to 10 feet. feet for commercial applications. IH I-- requires fewer roof attachments, g s r * to reducing the number of roof `" • 6'spanning capability • 10'spanning capability • 12'spanning capability Z D penetrations and the amount • Moderate load capability • Heavy load capability • Extreme load capability ?• IL • of installation time. • Clear&black anodized finish • Clear&black anodized finish • Clear anodized finish Q > N • Internal splices available internal splices available • Internal splices available = Q CV • ; , F W Ct rn x Rail Selection Q IA- O : W ,# The table below was prepared in compliance with applicable engineering codes and standards.*Values are �—► based on the following criteria:ASCE 7-16,Gable Roof Flush Mount, Roof Zones 1 &2e, Exposure B, Roof co • Slope of 8 to 20 degrees and Mean Building Height of 30 ft.Visit{ronRidge.com for detailed certification letters. rn co t o Load Rail Span Snow(PSF) Wind(MPH) 4' IIIIMI 8. 10 12' • i , ; �, $ Force-Stabilizing Curve 90 V ! w ,` *,094 • Sloped roofs generate both vertical and lateral 120 o r'z`+ '� _a ' forces on mounting rails which can cause them '•-: to bend and twist.The curved shape of XR Rails None ';:, ,;: is specially designed to increase strength in both 140 - XR10 -. + ' Z z x directions while resisting the twisting.This unique O m a l �' feature ensures greater security during extreme 160 5 & weather and a longer system lifetime. } ce m .� f-i* 90 al o 120 r 20 ;S 140 z h 160 w 90 :, - 30 .-` i ---- "`""""' -- 160 PERMIT DEVELOPER Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 90 � DATE 09/09/2022 XR Rails are IronRidge offers All XR Rails are made of 6000-series 40 • compatible with a range of tilt leg aluminum alloy,then protected with an i 160 } DESIGNER ORM iiiiii FlashFoot and r^t options for flat anodized finish.Anodizing prevents surface i other pitched roof t I roof mounting and structural corrosion,while also providing 80 160 e attachments. applications. a more attractive appearance. . - REVIEWER 120 160 SHEET NAME :r .-. , than for con eyi-g gent rat rail capab-,42eea tine approv<+c er.:£.ator.le Ye.:l o;actual nesigr;-•.v dance • . RACKING ...-. .� .. '" ..:. � ,�, x� ATA . � ; � n � � � �.� .-� �r � � x 1.�-=�.�.,fa �. �,� D SHEET ... 3�4' •fi yx.- 'y„ , ....., l .'..vi:...l}a ,...._ `.....-........_^_1.z_c ...__ 1 .:... 'x...r.. � .....n�._,. .... ..-.h_'.+�... phv ��°i —..f i SHEET NUMBER DS-05